Commit Graph

216 Commits

Author SHA1 Message Date
Joseph Doherty 14ec145487 test(ab): hw4 evidence - mixed MSP read (#582), listing order (#572) on the press; AbLegacy bit-write test; gate-results + docs
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-09 04:10:22 -04:00
Joseph Doherty 82750cccb9 Merge hw3-alarms (#656 atomic ActiveAcknowledged + re-statement flag for native alarms)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-09 00:14:47 -04:00
Joseph Doherty e138e39778 docs(alarms): #656 re-statement flag + ActiveAcknowledged kind (AlarmTracking, OpcUaClient, Galaxy, ScriptedAlarms, CLAUDE.md)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 23:43:09 -04:00
Joseph Doherty 67059e479f docs(#655): history is server-side only; rewrite OPC-009 and stale driver-history references
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 23:36:25 -04:00
Joseph Doherty 585fd8e29a Merge hw2-makino: hardware live-gate fixes (hw2-makino)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 21:35:10 -04:00
Joseph Doherty a92fb81f00 fix(twincat): review — a connect failure no longer burns the sum-chunk warning; doc precision
- ReadBucketAsync: the once-per-device "sum-read chunk failed" Warning fires only after a successful
  connect; a connect/backoff failure is the connect path's to report. TwinCATSumChunkWarningTests pins
  it (no warning across connect failures, exactly one across two later failing sum polls; red without
  the guard) plus a source guard that ReadGroupAsync builds its SumRead only via CreateSumRead.
- Docs: diagnostics live-gated via the driver harness (/hosts not exercised); TC2 costs 8 reads on the
  first tick and after each reconnect, then <= 4; read counts attributed to the unit tests.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 21:26:26 -04:00
Joseph Doherty 664ff75ee2 fix(twincat): #645 live gate — sum-read never worked on hardware; TC2 diagnostics fallback
Read-only live gate on Elma presses Z35474 (TC3 3.1.4024) and Z34834 (TC2 2.11):

- Sum-read: every chunk came back BadCommunicationError. Beckhoff's
  SumRead(IList<IgIoSumReadEntity>) ctor casts to IList<SumDataEntity>, which
  throws InvalidCastException for a List<> (only an array survives via
  covariance). The fake-client tests never built a real SumRead. New
  AdsTwinCATClient.CreateSumRead passes an array; TwinCATSumReadConstructionTests
  pins it (red on the List form) plus a falsifiability control on the library.
  After the fix: 59 tags, status identical everywhere, values identical on every
  non-moving tag, ~0.35-0.66 s vs ~2.7 s per poll; TC2 CE 2.11 answers sum reads.
- An unexpected sum chunk failure now logs one Warning per device (it was
  invisible: the health message was overwritten by the next good read).
- Diagnostics: TC2 has no TwinCAT_SystemInfoVarList; fall back to .SYSTEMINFO /
  .SYSTEMTASKINFOARR[1] once the TC3 name answers not-found (live: all six keys).
- #612 browse: Flat verified on TC3 (10,770 leaves; VirtualTree 1,459 strict
  subset) — comment and docs updated, no load-mode option needed.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 21:17:44 -04:00
Joseph Doherty c940349fe8 fix(focas): serialize per-device connect so concurrent loops share one session; docs: signed PMC Byte in the #259 override recipe + Makino live notes
The hw2 read-only Makino gate (Z-34184, 31i-B) logged the fixed-tree bootstrap failing with
ObjectDisposedException: FocasWireClient. EnsureConnectedAsync was unserialized: the alarm poll
loop and the fixed-tree loop both reached it right after init, the second saw the first's
still-connecting client as not connected, disposed it and opened a second session, and the first
caller's catch then disposed the second caller's client (and recorded a spurious backoff failure).
A per-device ConnectGate now serializes the connect with a re-check after acquire, and the failure
path disposes only its own client. FocasConcurrentConnectTests goes red without the gate.

Docs: a Byte PMC tag is signed, so G12 at 100% feed override reads -101 on the Makino and the
recipe's 255 - value gave 356; recipe now masks. Adds the live statinfo/alarm-watch observations.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 21:16:31 -04:00
Joseph Doherty e7dd742541 Merge b647-focas-alarms: FOCAS native alarms reach Part 9 conditions (ALARM: address) + respawn keeps acks host-side (#647)
v2-ci / build (push) Successful in 4m57s
v2-ci / unit-tests (push) Failing after 21m6s
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 20:46:13 -04:00
Joseph Doherty bac93744ce fix(alarms): #647 re-review — re-statement needs the same message; CNC refusal is not comms loss; worst-of health
R1: NativeAlarmProjector treats Raise-on-Active as a re-statement only when the message matches what
the condition shows; a different alarm appearing during a respawn un-acks and writes its alerts row.
FOCAS condition messages are a deterministic function of the matched set (tested across fresh driver
instances and reordered lists); Runtime E2E now covers both the same alarm and a new one during a
respawn. Residual (source message determinism) documented in AlarmTracking.md.

R2: a non-OK cnc_rdalmmsg2 return is thrown as FocasWireException{Rc} and classified as a CNC
refusal: conditions get a quality-only BadNotSupported once, one Warning, polling continues, and
driver health is untouched (no 90 s watchdog reconnect loop on a production control). Only transport
faults degrade (falsification control in the test).

R3: alarm-path health is tracked apart from the value path and combined in GetHealth: worst state,
later LastSuccessfulRead. A good value read can no longer mask a failing alarm read (no per-poll
/hosts flip) and a good alarm read cannot mask a value Degraded.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 20:45:32 -04:00
Joseph Doherty 89961af6e6 fix(alarms): #647 review — Raise on an active condition is a re-statement; FOCAS outage quality + health
MAJOR-1: a deploy that changes a driver's config respawns it, and the fresh instance's empty told
record re-sent Raise for every still-active alarm, un-acking acknowledged conditions and writing a
duplicate "Activated" alerts row. NativeAlarmProjector now treats Raise on an already-active
condition as a re-statement (keeps Acked; ForwardNativeAlarm skips the alerts row); only Retrigger
(or inactive->active) un-acks. Sources whose upstream ack state is authoritative send Retrigger for
an unacked re-statement: OpcUaClient on first sight (no prior told), Galaxy for an unacked active
snapshot entry. Runtime E2E drives a FRESH FOCAS driver after a redeploy and asserts the ack survives.

MAJOR-2: a failed FOCAS alarm read annotates each subscribed condition BadNoCommunication once per
outage (#626 quality-only path) with one Warning (MINOR-6), lifted to Good on recovery; failed alarm
reads degrade driver health with LastSuccessfulRead frozen (successful ones advance it), so an
alarm-only driver trips the #527 comms-loss watchdog.

MINOR-3 CLAUDE.md #630 bullet; MINOR-4 split line; MINOR-5 a non-empty cnc_rdalmmsg2 payload that
fits neither stride throws; MINOR-7 value-tag + parsed-address tables are built and swapped, never
cleared in place under the retained poll engine. Docs corrected (FOCAS.md, AlarmTracking.md, CLAUDE.md).

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 20:18:03 -04:00
Joseph Doherty 482bafdfac feat(focas): CNC alarms reach Part 9 conditions via ALARM: tags (#647)
An ALARM: address (*, <Type>, <Type>/<n>, <Type>/<lo>-<hi>, T<code>, OTHER) on a raw tag that
also carries the cross-driver alarm object is ONE condition with ConditionId == RawPath and a
Kind (Raise / Retrigger / Clear), so DriverHostActor.ForwardNativeAlarm routes it and
NativeAlarmProjector activates it. Fixes all seven triage defects:

1. SubscribeAlarmsAsync treated the host's RawPaths as device hosts -> nothing polled.
2. Decorated "{host}#{Type}:{Number}" ConditionId -> every event dropped.
3. No Kind -> projector kept prior state.
4. WireFocasClient.ReadAlarmsAsync answered [] on failure -> mass clear + un-acked re-raise.
   It now throws; a failed device read keeps every condition's state.
5. Acks lost on reconnect -> told-record dedup (MTConnect #626 pattern) held for the driver's
   lifetime; same-set re-subscribe / re-init re-raise nothing; changed set prunes leavers only.
6. Subscribe threw while AlarmProjection.Enabled=false -> the tag is the opt-in; flag is a no-op.
7. Alarm tags could not be authored -> ALARM: grammar (FocasAlarmSelector, Contracts) backs the
   editor, the address picker, the deploy-time inspector and driver init.

Severity: authored alarm.severity -> exact OpcUaSeverity; else the 16i-era type bucket. The type
table stays the only one (moved to Contracts, documented 16i-era; 30i codes not invented; raw
T<code> selector + raw code in every message). Read-only: ack is server-side. Also clears the
value table on a re-initialise (#630 gap that let a removed/moved tag keep reading).

E2E: Runtime.Tests FocasNativeAlarmEndToEndTests drives the real driver through the real
DriverHostActor and asserts the condition goes Active then inactive.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:46:48 -04:00
Joseph Doherty 46bf939ff5 Merge b647-twincat: ADS sum-read (opt-in) + TwinCAT diagnostics on /hosts (#645 #310/#314, #612 docs)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:33:22 -04:00
Joseph Doherty 802781b645 fix(twincat): read-singly fallback for any non-comms overall sum error, once-per-device warning, wording (#645 re-review)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:33:09 -04:00
Joseph Doherty 83ab123466 Merge b647-opcua-histstatus: OpcUaClient HistoryRead honours per-node StatusCode (#649)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:30:06 -04:00
Joseph Doherty b8c2136732 fix(opcuaclient): #649 review minors - CodeBits match, Bad-only exception ctor, BadNoData + Raw-resume tests, latent-impact docs
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:29:47 -04:00
Joseph Doherty fbcb521d1b fix(twincat): review fixes for sum-read and diagnostics (#645)
Strict width+kind eligibility for sum-batched scalars (others read singly); latch only on ADS
1793/1794, split 1792/1797/1798 without latching; 32 KiB per-command budget and 500-item ceiling;
short sum response handled per item. Diagnostics: opt-in diagnosticsEnabled (default off), reuse the
probe's ReadState, sample after the host-state transition, JitterMs renamed HeadroomMs, compact
per-device line so many devices fit the 16-entry cap, unavailable-symbol latch cleared on reconnect.
AdminUI: min/max on sum-read max, diagnostics checkbox. Pure planner extracted and unit-tested.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:29:35 -04:00
Joseph Doherty 0be21be393 Merge b647-mtc-dataset: MTConnect DATA_SET/TABLE as JSON strings; EVENT enumerations parked (#650)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:21:34 -04:00
Joseph Doherty 9631a40f1f fix(mtconnect): resetTriggered only resets data sets; empty set is Good {}; re-baseline test (#650 review)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:20:23 -04:00
Joseph Doherty af19db4ed1 feat(twincat): opt-in ADS sum-read and /hosts diagnostics bag; refresh TwinCAT backlog (#645, #612)
Sum-read (#310): batches a poll's reads per device into sum commands capped at sumReadMaxItems,
per-item ADS errors mapped per tag, falls back to individual reads when the target refuses the
command. Diagnostics (#314): ADS state, app name, online-change count, task cycle/exec/jitter via
IDriverDiagnostics. Re-implemented against the current raw-byte read path (stranded auto/driver-gaps
commits predate it). Sum-write not ported. Unit tests only; live gate pending a route.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:18:42 -04:00
Joseph Doherty 22e79112b6 fix(opcuaclient): HistoryRead honours the per-node StatusCode (BadAggregateNotSupported + other Bad) instead of returning empty data (#649)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:16:55 -04:00
Joseph Doherty 4feea47c43 Merge b647-focas-fixture: OtOpcUa-owned FOCAS fixture (#651) + FOCAS backlog docs (#633)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:16:41 -04:00
Joseph Doherty f8f8eb9fb8 feat(mtconnect): serve DATA_SET/TABLE as compact JSON strings; park EVENT enumerations (#650)
Parser captures Entry/Cell content; the observation index merges /sample deltas
into the /current baseline (resetTriggered replaces, removed deletes, UNAVAILABLE
drops). Fixture gains a TABLE item and periodic DATA_SET/TABLE churn.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:15:32 -04:00
Joseph Doherty dd05baedd6 refactor(opcuaclient): remove vestigial TargetNamespaceKind + UnsMappingTable (#648)
Nothing read the mapping table beyond the startup validator; v3 UNS projection is
explicit via UnsTagReference. Legacy keys in stored DriverConfig are ignored (pinned).
Reverts the docker-dev opc-plc seed workaround from fdee129f.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:14:37 -04:00
Joseph Doherty 7dd64b8ccd feat(focas): OtOpcUa-owned otopcua-focas-fixture stack (#651) + FOCAS backlog docs (#633)
Fixture renamed off ignitionoee's otopcua-focas-sim, port 8193 published, project label,
default endpoint 10.100.0.35:8193; infra/dev-environment docs. FOCAS.md: MACRO:3901 parts
count, PMC override + cycle-time recipes, won't-do/blocked backlog.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:12:13 -04:00
Joseph Doherty 3bf874ae44 Merge b640-619alm: OpcUaClient native alarms route to RawPath conditions + ConditionRefresh; docker-dev opc-plc seed (#619)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:26:47 -04:00
Joseph Doherty 5af9aae2d4 Merge b640-641: native alarm state survives rebuild; projector pruned; AbCip ConditionId=RawPath (#641)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:26:47 -04:00
Joseph Doherty 8f5b265db8 fix(opcuaclient): native-alarm ConditionRefresh + transition table, branch, dedup and thread-safety fixes (#619 re-review)
Re-review of 3de2cc3b/454775c6:
- AlarmTransitions could not reach (inactive, unacked): (active,acked)->(inactive,unacked) emitted Clear
  (host stayed acked) and a first-seen cleared-unacked condition emitted nothing. The table is now total;
  an exhaustive test replays every (prior, target) pair through the projector's semantics.
- The per-RawPath read-compute-emit was a lock-free TryGetValue/set across SDK publish threads; it now runs
  under one lock with the projection and emission.
- Condition BRANCH events (non-null BranchId) were projected (flipping the trunk) and remembered as the ack
  target (acking the branch); they are dropped. BranchId is select clause 9.
- EventId is copied, not aliased from the decoded notification.
- An unchanged state re-emitted Unspecified; it now emits nothing unless message/severity changed (an
  Unspecified projects from the host projector's default after a redeploy reset it).
- Exact upstream severity rides OpcUaSeverity (#626) instead of being re-bucketed.
- ShutdownAsync no longer forgets the last-told state: a reinit re-subscribes the same set and the refresh
  would otherwise re-raise every acked alarm. A CHANGED set (host rebuilt) forgets it.

ConditionRefresh: called after the alarm event item is created, after an in-place reconnect (subscriptions
found on the new session by display name, since a recreate clones them) and on RefreshRequired. Refresh
markers are never projected. BadNotSupported/BadMethodInvalid/... logs once. Wire test: a condition already
active before subscribe is reported Raise; a release+resubscribe refresh re-raises nothing (falsified by
disabling the refresh call).

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:13:54 -04:00
Joseph Doherty 9b74a65b25 Merge b640-640: driver diagnostics surface on /hosts (#640)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:13:34 -04:00
Joseph Doherty 64d2514e2a fix(abcip): report ALMD transitions with ConditionId = RawPath and a Kind (#641)
Found while verifying item 4 of #641. The host routes a native alarm transition
on an exact ConditionId == RawPath match (DriverHostActor.ForwardNativeAlarm),
but AbCipAlarmProjection emitted "{ref}#active" and no Kind, so every ALMD
raise/clear was dropped as "no alarm condition" — and even if routed, an
Unspecified kind projects no state change. It now reports the subscribed
reference (the RawPath) and Raise/Clear. A host test pins that a decorated id
is dropped.

FOCAS has the same id shape plus a device filter keyed by host address (a
RawPath subscription polls nothing); it needs a mapping decision and is
documented in docs/drivers/FOCAS.md rather than patched here.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:08:47 -04:00
Joseph Doherty 3fe6cbb905 fix(mtconnect): on a changed alarm set forget only the conditions that left (#641)
The driver cleared its whole "last told" record whenever the subscribed alarm
set changed, assuming the rebuild that accompanies an alarm-bearing delta had
reset every condition node. The server now carries each surviving native
condition's state (acknowledgement included) across the rebuild, so re-raising a
survivor would un-acknowledge it. Only entries that left the set are dropped; a
condition that comes back later is told again onto its fresh node.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:06:57 -04:00
Joseph Doherty 454775c67c fix(opcuaclient): derive AlarmTransitionKind from upstream ActiveState/AckedState (#619 review)
NativeAlarmProjector derives Active/Acked ONLY from AlarmEventArgs.Kind, and this driver
never set it - every routed event projected Unspecified, leaving the condition inactive+acked
(only Message/Severity moved). The live-gate expectation 'toggling Active as opc-plc cycles'
could not have passed. Select ActiveState/Id + AckedState/Id (two-element browse paths) and
emit the Kind sequence that moves the projector from the state last told to the host to the
event's (Raise+Acknowledge when a notification carries both).

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:04:48 -04:00
Joseph Doherty baf8cc48c3 Merge b640-small: CI readme drift check, SlowUnit tags, LDAP bind pw var, historian/MTConnect docs (#606 #619 #600 #613)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:03:59 -04:00
Joseph Doherty 216dc63a28 Merge b640-focas: FOCAS Status/ subtree, PMC range coalescing, parts-count docs (#257 #266 #258, tracker #633)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:03:53 -04:00
Joseph Doherty 9244ae2c31 docs(mtconnect): feature status table; EVENT enums + DATA_SET/TABLE listed as unsupported (#613)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:03:26 -04:00
Joseph Doherty 3de2cc3ba8 fix(opcuaclient): alarm index survives namespace reorder; match condition node first; ack with real EventId (#619 review)
The alarm index was keyed on ns=N strings resolved once at subscribe time, while an
in-place SDK reconnect transfers the subscription without re-running it - a remote
namespace reorder silently orphaned every alarm tag. Keys are now nsu= on both sides.
Events match the authored nodeId against the event's ConditionId first, then its
SourceNode, so several conditions on one source can be authored 1:1. Acknowledge
passes the EventId of the event that named the remembered condition (paired, so node
and EventId can never come from different conditions) instead of an empty one.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:02:21 -04:00
Joseph Doherty 487d394cde docs(focas): Status/ flags, PMC coalescing, parts count via PARAM:6711, read-only policy (#257 #266 #258)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 16:59:08 -04:00
Joseph Doherty 73e54656f8 Merge b640-s7 (S7 live codec coverage + STRING/DT BadOutOfRange #632)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 16:57:59 -04:00
Joseph Doherty c2bdb7d5de feat(hosts): driver diagnostics channel on /hosts, S7 negotiated PDU size first (#640)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 16:57:38 -04:00
Joseph Doherty 73fdb80157 fix(ablegacy): indirect element index up to 999 on PLC-5; clear IndirectLastName on dispose
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 16:56:58 -04:00
Joseph Doherty d93491499d chore(docker-dev): seed OpcUaClient driver for opc-plc + doc native-alarm source semantics (#619)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 16:55:13 -04:00
Joseph Doherty b0b0ce9c77 feat(ablegacy): resolve indirect addresses at read/write time (#646)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 16:53:56 -04:00
Joseph Doherty 2aae3c094f test(s7): live python-snap7 coverage for the #632/#638 codecs, TSAP override and PDU size (#632)
Extends the s7_1500 profile (DB1 2048 bytes, 'hex' seed type) with distinct
non-zero seeds for STRING/WSTRING/CHAR/WCHAR/DTL/DATE/TOD/TIME/S5TIME plus
undecodable buffers; S7_1500CodecTests covers reads, BadOutOfRange paths,
write round-trips (S7_SIM_ALLOW_WRITES=1), TSAP keys and negotiated PDU size.
Skips when S7_SIM_ENDPOINT is unreachable.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 16:53:02 -04:00
Joseph Doherty 95b389497a test+docs(mtconnect): wire test for the Unavailable blip + ack survival; docs for the review rulings (#626)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 15:44:50 -04:00
Joseph Doherty 6a5f5c5a28 Merge branch 'master' into b626-626 2026-10-08 15:32:51 -04:00
Joseph Doherty f4d513e111 test+docs(mtconnect): CONDITION alarm wire test, reinit barrier, docs (#626)
MTConnectConditionAlarmWireTests drives a scripted Agent's Fault/Normal through the real
driver, NativeAlarmProjector and sink to a client event subscription on the raw device
folder. docs/drivers/MTConnect.md replaces 'CONDITION v1: plain String' with the alarm
mapping, opt-in authoring, multi-condition, ack, replay and comms-loss behaviour, and a
live-check recipe; EVENT vocabularies as enumerations marked won't-fix. AlarmTracking.md
lists the MTConnect source and the two new AlarmEventArgs fields.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 15:13:30 -04:00
Joseph Doherty 1219b7b13e fix(opcuaclient): review fixes - drop driver-side OperationLimits chunking (SDK batches), diagnostics as OTel counter, safe discovery selection, options validation at load (#273 #275 #276 #277 #278)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 14:55:53 -04:00
Joseph Doherty 935ba8d1d4 Merge branch 'master' into b626-opcuaclient 2026-10-08 14:47:49 -04:00
Joseph Doherty e6028678b3 docs(mtconnect): upgrade note for existing multi-Device MTConnect drivers (#628)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 14:44:44 -04:00
Joseph Doherty 723392e3da Merge b626-mtconnect (batch #626+)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 14:43:45 -04:00