Commit Graph

228 Commits

Author SHA1 Message Date
Joseph Doherty 0abce36ca3 fix(ablegacy): translate S/O/I and R status bits for libplctag's PCCC parser (#659)
libplctag 2.6.0 (bundled by libplctag 1.5.2 / NativeImport 1.0.41) pccc.c needs an
explicit file number (parse_pccc_file_num; S is only the status file when a digit
follows) and has no R-file status-bit mnemonics (sub_element_lookup: con/len/pos only;
a /bit is refused on a 6-byte element). So the canonical S:0 (the default probe),
O:0/3, I:0/0 and R6:0.DN failed with BadCommunicationError on a real MicroLogix 1400
while native read them.

LibplctagLegacyName (libplctag adapter only) now emits S2:/O0:/I1: (the native
encoder's implicit file numbers) and R6:0.CON/<bit> for status bits libplctag lacks
(R EN/EU/DN/EM/ER/UL/IN/FD, C UA), bit numbers taken from the native table. The
authored grammar is unchanged. Unit tests pin the translation per family and check,
through a model of the pccc.c parser, that the translated name addresses exactly
what the native encoder does (46 fail without the fix). Live: Z-33323 idle, reads
only - libplctag now equals native for S/O/I/R status bits; controls unchanged.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-09 05:34:09 -04:00
Joseph Doherty e0e8c4267a docs(ablegacy): drop stale simulator-only claims after the MicroLogix evidence
v2-ci / build (push) Successful in 4m54s
v2-ci / unit-tests (push) Failing after 20m29s
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-09 05:23:40 -04:00
Joseph Doherty beedac8218 docs(ablegacy): #592 real MicroLogix 1400 evidence (native reads/writes pass; libplctag fails S/O/I/status bits)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-09 05:23:28 -04:00
Joseph Doherty 12aa293cdc docs(abcip): #611 live member-write gate on Z35162 (native DINT/BIT/REAL members, restored)
v2-ci / build (push) Successful in 4m47s
v2-ci / unit-tests (push) Failing after 23m3s
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-09 04:49:19 -04:00
Joseph Doherty 6c6800e513 Merge hw4-udtwrite (#592/#611)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe

# Conflicts:
#	docs/drivers/AbCip.md
2026-10-09 04:32:03 -04:00
Joseph Doherty bd20978568 Merge hw4-alma (#592/#611)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-09 04:31:54 -04:00
Joseph Doherty f85fc8fbeb fix(abcip): #611 review round 1 — native keeps BOOL type distinction, WriteWidthRefusal tests, doc caveats
- L2: WriteWidthRefusal leaves a BOOL over a wider value to a runtime that sees the CIP
  type (native): mistyped integer member -> BadTypeMismatch (as its read), 0xD3 BOOL-array
  DWORD -> BadNotSupported; libplctag keeps BadNotSupported for both (size only).
- L4: direct theory over WriteWidthRefusal (1/2/4/8 widths incl LINT/ULINT/LREAL, String/Dt,
  unknown size) + array/bit-selector exemptions with a non-vacuous control.
- L1: CLAUDE.md member/BIT-member writes are ab_server-proven only.
- L3: patch 0003 blind spots documented (Docker README, AbServer-Test-Fixture.md); nits.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-09 04:31:45 -04:00
Joseph Doherty 5d7c53bb19 fix(abcip): ALMA review round 2 - IsRestatement contract docs, ALMD no-InAlarm warning, un-ack retrigger
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-09 04:30:56 -04:00
Joseph Doherty 5018627b35 feat(abcip): #611 discovered UDT member writes + whole-UDT refusal by decision
Item 2 — controller-discovered UDT members are writable on both transports once
browse-committed and authored ReadWrite (writability is the operator's: the commit
lands AccessLevel Read with no writable key). The write names the member (one CIP
symbolic segment per member), its own type, its own bytes. BIT members are supported:
Z-35162 (read-only probe) exposes a UDT BIT member as a 1-byte 0xC1 BOOL, so the
controller applies the bit and the hidden host's other bits are never in the request.

- AbCipDriver: pre-write width check on BOTH transports (libplctag patched part of
  its read buffer and sent it all): BadTypeMismatch, Bool over a wider value
  BadNotSupported; nothing sent, handle kept, health untouched, warn once.
- A runtime NotSupportedException is a refusal: no longer latches Degraded.

Item 3 — whole-UDT writes refused BadNotSupported before any runtime exists, by
decision (a structure write overwrites hidden hosts + padding), documented.

ab_server patch 0003: serve member paths from dotted flat tags (UdtSeg.*), and
accept libplctag's pad byte on 1-byte writes (stock ab_server refused every
libplctag BOOL/SINT write with 0x03). New AbCipUdtMemberWriteTests (both
transports), AbCipDiscoveredMemberWriteTests, native request-byte theory, and a
browse-commit mapper pin. Docs: AbCip.md Member writes / Whole-UDT writes / Known
gaps, fixture docs, CLAUDE.md AB section.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-09 04:23:59 -04:00
Joseph Doherty 83d8de303c fix(abcip): ALMA review round 1 + ALMD polls InAlarm (not InFaulted)
M1 drop-out is a no-row Unspecified+IsRestatement update (projector case); M2 ack judged over every declared
limit; L1 ActiveAcknowledged for an already-acked new limit; L2 Bad Acked/severity carried/skipped; L3 host
end-to-end test; L4 BOOL member-by-member tests + mixed ALMD/ALMA; L5 detection requires no plain Acked.
ALMD active bit is InAlarm per Rockwell's ALMD reference; InFaulted is input health.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-09 04:22:45 -04:00
Joseph Doherty 9e894decb0 docs(ab): hw4 evidence fix round 1 - bit-write gap provenance, README/CLI/fixture docs, libplctag-deletion gap
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-09 04:12:53 -04:00
Joseph Doherty 14ec145487 test(ab): hw4 evidence - mixed MSP read (#582), listing order (#572) on the press; AbLegacy bit-write test; gate-results + docs
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-09 04:10:22 -04:00
Joseph Doherty b3838fcce9 feat(abcip): ALMA (ALARM_ANALOG) alarm projection (#611 item 1)
Detect ALMA by declared *InAlarm members; one condition per tag keyed on RawPath; severity/message from
the most severe active limit; Raise/ActiveAcknowledged/Retrigger/Clear/Acknowledge; ack writes OperAckAll.
Unit-tested over fake runtimes only (no ab_server ALMA support, Z35162 has none).

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-09 04:09:47 -04:00
Joseph Doherty 82750cccb9 Merge hw3-alarms (#656 atomic ActiveAcknowledged + re-statement flag for native alarms)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-09 00:14:47 -04:00
Joseph Doherty e138e39778 docs(alarms): #656 re-statement flag + ActiveAcknowledged kind (AlarmTracking, OpcUaClient, Galaxy, ScriptedAlarms, CLAUDE.md)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 23:43:09 -04:00
Joseph Doherty 67059e479f docs(#655): history is server-side only; rewrite OPC-009 and stale driver-history references
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 23:36:25 -04:00
Joseph Doherty 585fd8e29a Merge hw2-makino: hardware live-gate fixes (hw2-makino)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 21:35:10 -04:00
Joseph Doherty a92fb81f00 fix(twincat): review — a connect failure no longer burns the sum-chunk warning; doc precision
- ReadBucketAsync: the once-per-device "sum-read chunk failed" Warning fires only after a successful
  connect; a connect/backoff failure is the connect path's to report. TwinCATSumChunkWarningTests pins
  it (no warning across connect failures, exactly one across two later failing sum polls; red without
  the guard) plus a source guard that ReadGroupAsync builds its SumRead only via CreateSumRead.
- Docs: diagnostics live-gated via the driver harness (/hosts not exercised); TC2 costs 8 reads on the
  first tick and after each reconnect, then <= 4; read counts attributed to the unit tests.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 21:26:26 -04:00
Joseph Doherty 664ff75ee2 fix(twincat): #645 live gate — sum-read never worked on hardware; TC2 diagnostics fallback
Read-only live gate on Elma presses Z35474 (TC3 3.1.4024) and Z34834 (TC2 2.11):

- Sum-read: every chunk came back BadCommunicationError. Beckhoff's
  SumRead(IList<IgIoSumReadEntity>) ctor casts to IList<SumDataEntity>, which
  throws InvalidCastException for a List<> (only an array survives via
  covariance). The fake-client tests never built a real SumRead. New
  AdsTwinCATClient.CreateSumRead passes an array; TwinCATSumReadConstructionTests
  pins it (red on the List form) plus a falsifiability control on the library.
  After the fix: 59 tags, status identical everywhere, values identical on every
  non-moving tag, ~0.35-0.66 s vs ~2.7 s per poll; TC2 CE 2.11 answers sum reads.
- An unexpected sum chunk failure now logs one Warning per device (it was
  invisible: the health message was overwritten by the next good read).
- Diagnostics: TC2 has no TwinCAT_SystemInfoVarList; fall back to .SYSTEMINFO /
  .SYSTEMTASKINFOARR[1] once the TC3 name answers not-found (live: all six keys).
- #612 browse: Flat verified on TC3 (10,770 leaves; VirtualTree 1,459 strict
  subset) — comment and docs updated, no load-mode option needed.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 21:17:44 -04:00
Joseph Doherty c940349fe8 fix(focas): serialize per-device connect so concurrent loops share one session; docs: signed PMC Byte in the #259 override recipe + Makino live notes
The hw2 read-only Makino gate (Z-34184, 31i-B) logged the fixed-tree bootstrap failing with
ObjectDisposedException: FocasWireClient. EnsureConnectedAsync was unserialized: the alarm poll
loop and the fixed-tree loop both reached it right after init, the second saw the first's
still-connecting client as not connected, disposed it and opened a second session, and the first
caller's catch then disposed the second caller's client (and recorded a spurious backoff failure).
A per-device ConnectGate now serializes the connect with a re-check after acquire, and the failure
path disposes only its own client. FocasConcurrentConnectTests goes red without the gate.

Docs: a Byte PMC tag is signed, so G12 at 100% feed override reads -101 on the Makino and the
recipe's 255 - value gave 356; recipe now masks. Adds the live statinfo/alarm-watch observations.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 21:16:31 -04:00
Joseph Doherty e7dd742541 Merge b647-focas-alarms: FOCAS native alarms reach Part 9 conditions (ALARM: address) + respawn keeps acks host-side (#647)
v2-ci / build (push) Successful in 4m57s
v2-ci / unit-tests (push) Failing after 21m6s
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 20:46:13 -04:00
Joseph Doherty bac93744ce fix(alarms): #647 re-review — re-statement needs the same message; CNC refusal is not comms loss; worst-of health
R1: NativeAlarmProjector treats Raise-on-Active as a re-statement only when the message matches what
the condition shows; a different alarm appearing during a respawn un-acks and writes its alerts row.
FOCAS condition messages are a deterministic function of the matched set (tested across fresh driver
instances and reordered lists); Runtime E2E now covers both the same alarm and a new one during a
respawn. Residual (source message determinism) documented in AlarmTracking.md.

R2: a non-OK cnc_rdalmmsg2 return is thrown as FocasWireException{Rc} and classified as a CNC
refusal: conditions get a quality-only BadNotSupported once, one Warning, polling continues, and
driver health is untouched (no 90 s watchdog reconnect loop on a production control). Only transport
faults degrade (falsification control in the test).

R3: alarm-path health is tracked apart from the value path and combined in GetHealth: worst state,
later LastSuccessfulRead. A good value read can no longer mask a failing alarm read (no per-poll
/hosts flip) and a good alarm read cannot mask a value Degraded.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 20:45:32 -04:00
Joseph Doherty 89961af6e6 fix(alarms): #647 review — Raise on an active condition is a re-statement; FOCAS outage quality + health
MAJOR-1: a deploy that changes a driver's config respawns it, and the fresh instance's empty told
record re-sent Raise for every still-active alarm, un-acking acknowledged conditions and writing a
duplicate "Activated" alerts row. NativeAlarmProjector now treats Raise on an already-active
condition as a re-statement (keeps Acked; ForwardNativeAlarm skips the alerts row); only Retrigger
(or inactive->active) un-acks. Sources whose upstream ack state is authoritative send Retrigger for
an unacked re-statement: OpcUaClient on first sight (no prior told), Galaxy for an unacked active
snapshot entry. Runtime E2E drives a FRESH FOCAS driver after a redeploy and asserts the ack survives.

MAJOR-2: a failed FOCAS alarm read annotates each subscribed condition BadNoCommunication once per
outage (#626 quality-only path) with one Warning (MINOR-6), lifted to Good on recovery; failed alarm
reads degrade driver health with LastSuccessfulRead frozen (successful ones advance it), so an
alarm-only driver trips the #527 comms-loss watchdog.

MINOR-3 CLAUDE.md #630 bullet; MINOR-4 split line; MINOR-5 a non-empty cnc_rdalmmsg2 payload that
fits neither stride throws; MINOR-7 value-tag + parsed-address tables are built and swapped, never
cleared in place under the retained poll engine. Docs corrected (FOCAS.md, AlarmTracking.md, CLAUDE.md).

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 20:18:03 -04:00
Joseph Doherty 482bafdfac feat(focas): CNC alarms reach Part 9 conditions via ALARM: tags (#647)
An ALARM: address (*, <Type>, <Type>/<n>, <Type>/<lo>-<hi>, T<code>, OTHER) on a raw tag that
also carries the cross-driver alarm object is ONE condition with ConditionId == RawPath and a
Kind (Raise / Retrigger / Clear), so DriverHostActor.ForwardNativeAlarm routes it and
NativeAlarmProjector activates it. Fixes all seven triage defects:

1. SubscribeAlarmsAsync treated the host's RawPaths as device hosts -> nothing polled.
2. Decorated "{host}#{Type}:{Number}" ConditionId -> every event dropped.
3. No Kind -> projector kept prior state.
4. WireFocasClient.ReadAlarmsAsync answered [] on failure -> mass clear + un-acked re-raise.
   It now throws; a failed device read keeps every condition's state.
5. Acks lost on reconnect -> told-record dedup (MTConnect #626 pattern) held for the driver's
   lifetime; same-set re-subscribe / re-init re-raise nothing; changed set prunes leavers only.
6. Subscribe threw while AlarmProjection.Enabled=false -> the tag is the opt-in; flag is a no-op.
7. Alarm tags could not be authored -> ALARM: grammar (FocasAlarmSelector, Contracts) backs the
   editor, the address picker, the deploy-time inspector and driver init.

Severity: authored alarm.severity -> exact OpcUaSeverity; else the 16i-era type bucket. The type
table stays the only one (moved to Contracts, documented 16i-era; 30i codes not invented; raw
T<code> selector + raw code in every message). Read-only: ack is server-side. Also clears the
value table on a re-initialise (#630 gap that let a removed/moved tag keep reading).

E2E: Runtime.Tests FocasNativeAlarmEndToEndTests drives the real driver through the real
DriverHostActor and asserts the condition goes Active then inactive.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:46:48 -04:00
Joseph Doherty 46bf939ff5 Merge b647-twincat: ADS sum-read (opt-in) + TwinCAT diagnostics on /hosts (#645 #310/#314, #612 docs)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:33:22 -04:00
Joseph Doherty 802781b645 fix(twincat): read-singly fallback for any non-comms overall sum error, once-per-device warning, wording (#645 re-review)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:33:09 -04:00
Joseph Doherty 83ab123466 Merge b647-opcua-histstatus: OpcUaClient HistoryRead honours per-node StatusCode (#649)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:30:06 -04:00
Joseph Doherty b8c2136732 fix(opcuaclient): #649 review minors - CodeBits match, Bad-only exception ctor, BadNoData + Raw-resume tests, latent-impact docs
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:29:47 -04:00
Joseph Doherty fbcb521d1b fix(twincat): review fixes for sum-read and diagnostics (#645)
Strict width+kind eligibility for sum-batched scalars (others read singly); latch only on ADS
1793/1794, split 1792/1797/1798 without latching; 32 KiB per-command budget and 500-item ceiling;
short sum response handled per item. Diagnostics: opt-in diagnosticsEnabled (default off), reuse the
probe's ReadState, sample after the host-state transition, JitterMs renamed HeadroomMs, compact
per-device line so many devices fit the 16-entry cap, unavailable-symbol latch cleared on reconnect.
AdminUI: min/max on sum-read max, diagnostics checkbox. Pure planner extracted and unit-tested.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:29:35 -04:00
Joseph Doherty 0be21be393 Merge b647-mtc-dataset: MTConnect DATA_SET/TABLE as JSON strings; EVENT enumerations parked (#650)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:21:34 -04:00
Joseph Doherty 9631a40f1f fix(mtconnect): resetTriggered only resets data sets; empty set is Good {}; re-baseline test (#650 review)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:20:23 -04:00
Joseph Doherty af19db4ed1 feat(twincat): opt-in ADS sum-read and /hosts diagnostics bag; refresh TwinCAT backlog (#645, #612)
Sum-read (#310): batches a poll's reads per device into sum commands capped at sumReadMaxItems,
per-item ADS errors mapped per tag, falls back to individual reads when the target refuses the
command. Diagnostics (#314): ADS state, app name, online-change count, task cycle/exec/jitter via
IDriverDiagnostics. Re-implemented against the current raw-byte read path (stranded auto/driver-gaps
commits predate it). Sum-write not ported. Unit tests only; live gate pending a route.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:18:42 -04:00
Joseph Doherty 22e79112b6 fix(opcuaclient): HistoryRead honours the per-node StatusCode (BadAggregateNotSupported + other Bad) instead of returning empty data (#649)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:16:55 -04:00
Joseph Doherty 4feea47c43 Merge b647-focas-fixture: OtOpcUa-owned FOCAS fixture (#651) + FOCAS backlog docs (#633)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:16:41 -04:00
Joseph Doherty f8f8eb9fb8 feat(mtconnect): serve DATA_SET/TABLE as compact JSON strings; park EVENT enumerations (#650)
Parser captures Entry/Cell content; the observation index merges /sample deltas
into the /current baseline (resetTriggered replaces, removed deletes, UNAVAILABLE
drops). Fixture gains a TABLE item and periodic DATA_SET/TABLE churn.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:15:32 -04:00
Joseph Doherty dd05baedd6 refactor(opcuaclient): remove vestigial TargetNamespaceKind + UnsMappingTable (#648)
Nothing read the mapping table beyond the startup validator; v3 UNS projection is
explicit via UnsTagReference. Legacy keys in stored DriverConfig are ignored (pinned).
Reverts the docker-dev opc-plc seed workaround from fdee129f.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:14:37 -04:00
Joseph Doherty 7dd64b8ccd feat(focas): OtOpcUa-owned otopcua-focas-fixture stack (#651) + FOCAS backlog docs (#633)
Fixture renamed off ignitionoee's otopcua-focas-sim, port 8193 published, project label,
default endpoint 10.100.0.35:8193; infra/dev-environment docs. FOCAS.md: MACRO:3901 parts
count, PMC override + cycle-time recipes, won't-do/blocked backlog.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:12:13 -04:00
Joseph Doherty 3bf874ae44 Merge b640-619alm: OpcUaClient native alarms route to RawPath conditions + ConditionRefresh; docker-dev opc-plc seed (#619)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:26:47 -04:00
Joseph Doherty 5af9aae2d4 Merge b640-641: native alarm state survives rebuild; projector pruned; AbCip ConditionId=RawPath (#641)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:26:47 -04:00
Joseph Doherty 8f5b265db8 fix(opcuaclient): native-alarm ConditionRefresh + transition table, branch, dedup and thread-safety fixes (#619 re-review)
Re-review of 3de2cc3b/454775c6:
- AlarmTransitions could not reach (inactive, unacked): (active,acked)->(inactive,unacked) emitted Clear
  (host stayed acked) and a first-seen cleared-unacked condition emitted nothing. The table is now total;
  an exhaustive test replays every (prior, target) pair through the projector's semantics.
- The per-RawPath read-compute-emit was a lock-free TryGetValue/set across SDK publish threads; it now runs
  under one lock with the projection and emission.
- Condition BRANCH events (non-null BranchId) were projected (flipping the trunk) and remembered as the ack
  target (acking the branch); they are dropped. BranchId is select clause 9.
- EventId is copied, not aliased from the decoded notification.
- An unchanged state re-emitted Unspecified; it now emits nothing unless message/severity changed (an
  Unspecified projects from the host projector's default after a redeploy reset it).
- Exact upstream severity rides OpcUaSeverity (#626) instead of being re-bucketed.
- ShutdownAsync no longer forgets the last-told state: a reinit re-subscribes the same set and the refresh
  would otherwise re-raise every acked alarm. A CHANGED set (host rebuilt) forgets it.

ConditionRefresh: called after the alarm event item is created, after an in-place reconnect (subscriptions
found on the new session by display name, since a recreate clones them) and on RefreshRequired. Refresh
markers are never projected. BadNotSupported/BadMethodInvalid/... logs once. Wire test: a condition already
active before subscribe is reported Raise; a release+resubscribe refresh re-raises nothing (falsified by
disabling the refresh call).

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:13:54 -04:00
Joseph Doherty 9b74a65b25 Merge b640-640: driver diagnostics surface on /hosts (#640)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:13:34 -04:00
Joseph Doherty 64d2514e2a fix(abcip): report ALMD transitions with ConditionId = RawPath and a Kind (#641)
Found while verifying item 4 of #641. The host routes a native alarm transition
on an exact ConditionId == RawPath match (DriverHostActor.ForwardNativeAlarm),
but AbCipAlarmProjection emitted "{ref}#active" and no Kind, so every ALMD
raise/clear was dropped as "no alarm condition" — and even if routed, an
Unspecified kind projects no state change. It now reports the subscribed
reference (the RawPath) and Raise/Clear. A host test pins that a decorated id
is dropped.

FOCAS has the same id shape plus a device filter keyed by host address (a
RawPath subscription polls nothing); it needs a mapping decision and is
documented in docs/drivers/FOCAS.md rather than patched here.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:08:47 -04:00
Joseph Doherty 3fe6cbb905 fix(mtconnect): on a changed alarm set forget only the conditions that left (#641)
The driver cleared its whole "last told" record whenever the subscribed alarm
set changed, assuming the rebuild that accompanies an alarm-bearing delta had
reset every condition node. The server now carries each surviving native
condition's state (acknowledgement included) across the rebuild, so re-raising a
survivor would un-acknowledge it. Only entries that left the set are dropped; a
condition that comes back later is told again onto its fresh node.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:06:57 -04:00
Joseph Doherty 454775c67c fix(opcuaclient): derive AlarmTransitionKind from upstream ActiveState/AckedState (#619 review)
NativeAlarmProjector derives Active/Acked ONLY from AlarmEventArgs.Kind, and this driver
never set it - every routed event projected Unspecified, leaving the condition inactive+acked
(only Message/Severity moved). The live-gate expectation 'toggling Active as opc-plc cycles'
could not have passed. Select ActiveState/Id + AckedState/Id (two-element browse paths) and
emit the Kind sequence that moves the projector from the state last told to the host to the
event's (Raise+Acknowledge when a notification carries both).

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:04:48 -04:00
Joseph Doherty baf8cc48c3 Merge b640-small: CI readme drift check, SlowUnit tags, LDAP bind pw var, historian/MTConnect docs (#606 #619 #600 #613)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:03:59 -04:00
Joseph Doherty 216dc63a28 Merge b640-focas: FOCAS Status/ subtree, PMC range coalescing, parts-count docs (#257 #266 #258, tracker #633)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:03:53 -04:00
Joseph Doherty 9244ae2c31 docs(mtconnect): feature status table; EVENT enums + DATA_SET/TABLE listed as unsupported (#613)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:03:26 -04:00
Joseph Doherty 3de2cc3ba8 fix(opcuaclient): alarm index survives namespace reorder; match condition node first; ack with real EventId (#619 review)
The alarm index was keyed on ns=N strings resolved once at subscribe time, while an
in-place SDK reconnect transfers the subscription without re-running it - a remote
namespace reorder silently orphaned every alarm tag. Keys are now nsu= on both sides.
Events match the authored nodeId against the event's ConditionId first, then its
SourceNode, so several conditions on one source can be authored 1:1. Acknowledge
passes the EventId of the event that named the remembered condition (paired, so node
and EventId can never come from different conditions) instead of an empty one.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:02:21 -04:00
Joseph Doherty 487d394cde docs(focas): Status/ flags, PMC coalescing, parts count via PARAM:6711, read-only policy (#257 #266 #258)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 16:59:08 -04:00
Joseph Doherty 73e54656f8 Merge b640-s7 (S7 live codec coverage + STRING/DT BadOutOfRange #632)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 16:57:59 -04:00