- HardwareGateGuardTests: only StringWriteGateTests may name a write path in HardwareGate/; the
allow-list is exactly the two Z-35162 (10.209.70.160) STRING tags; the opt-in, the (host, tag)
check and the AB_DIFF_ENDPOINT refusal are present. Proven red by a WriteAsync mutation.
- StringWriteGateTests: allow-list entries are (host, tag); any other endpoint is refused; skips
while AB_DIFF_ENDPOINT is set, like IntegrationWriteGate.
- AbCip.md #566: the close happened somewhere in the 16-60 s window; RST vs FIN not captured.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
A. #566 on a real CompactLogix (Z-35162, read-only): a class-3 connection idled 60 s past its
16 s timeout is closed at the TCP level, not with CIP 0x0107/0x0203; the next request fails on
its write (Broken pipe -> BadConnection) in 9 ms and the one after reopens. The transport already
handles this, so no production behaviour changed; the shape is pinned offline by
CipConnectionTests.A_target_that_resets_an_idle_session_... (FakeEipServer.ResetAllConnections),
proven red with a reconnect-skipping mutation. The diagnostics-only exchange tap now also sees
Forward Open replies (granted RPIs).
B. Native STRING write through the driver on Program:ES03_TemperatureControl._StrTmp: write,
read back, restored byte-exact (user-approved). Array write NOT run: the census's unreferenced
DINT[32] _SEQ_EP arrays are aliased sequencer step registers (raw L5X grep), so none qualifies.
#567 still impossible (a 128 B array / 88 B STRING never fragments).
New env-gated harness: AbCip.IntegrationTests/HardwareGate (IdleConnectionEvidenceTests,
StringWriteGateTests). Docs: gate results (hw5 section + raw output), AbCip.md, CLAUDE.md.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
- L2: WriteWidthRefusal leaves a BOOL over a wider value to a runtime that sees the CIP
type (native): mistyped integer member -> BadTypeMismatch (as its read), 0xD3 BOOL-array
DWORD -> BadNotSupported; libplctag keeps BadNotSupported for both (size only).
- L4: direct theory over WriteWidthRefusal (1/2/4/8 widths incl LINT/ULINT/LREAL, String/Dt,
unknown size) + array/bit-selector exemptions with a non-vacuous control.
- L1: CLAUDE.md member/BIT-member writes are ab_server-proven only.
- L3: patch 0003 blind spots documented (Docker README, AbServer-Test-Fixture.md); nits.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
Item 2 — controller-discovered UDT members are writable on both transports once
browse-committed and authored ReadWrite (writability is the operator's: the commit
lands AccessLevel Read with no writable key). The write names the member (one CIP
symbolic segment per member), its own type, its own bytes. BIT members are supported:
Z-35162 (read-only probe) exposes a UDT BIT member as a 1-byte 0xC1 BOOL, so the
controller applies the bit and the hidden host's other bits are never in the request.
- AbCipDriver: pre-write width check on BOTH transports (libplctag patched part of
its read buffer and sent it all): BadTypeMismatch, Bool over a wider value
BadNotSupported; nothing sent, handle kept, health untouched, warn once.
- A runtime NotSupportedException is a refusal: no longer latches Degraded.
Item 3 — whole-UDT writes refused BadNotSupported before any runtime exists, by
decision (a structure write overwrites hidden hosts + padding), documented.
ab_server patch 0003: serve member paths from dotted flat tags (UdtSeg.*), and
accept libplctag's pad byte on 1-byte writes (stock ab_server refused every
libplctag BOOL/SINT write with 0x03). New AbCipUdtMemberWriteTests (both
transports), AbCipDiscoveredMemberWriteTests, native request-byte theory, and a
browse-commit mapper pin. Docs: AbCip.md Member writes / Whole-UDT writes / Known
gaps, fixture docs, CLAUDE.md AB section.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
M1 drop-out is a no-row Unspecified+IsRestatement update (projector case); M2 ack judged over every declared
limit; L1 ActiveAcknowledged for an already-acked new limit; L2 Bad Acked/severity carried/skipped; L3 host
end-to-end test; L4 BOOL member-by-member tests + mixed ALMD/ALMA; L5 detection requires no plain Acked.
ALMD active bit is InAlarm per Rockwell's ALMD reference; InFaulted is input health.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
Ab.Transport.Tests: predecessor-wait counter instead of 300 ms (DeviceSessionPoolTests x2), throttle
queue/interval-park hooks instead of 50/100 ms (ForwardOpenThrottleTests x2), UnobservedTaskProbe with a
must-report control fault instead of N GC cycles (EncapsulationClientTests), re-armed keep-alive timer as
the control for the never-opened keep-alive test.
AbCip.Tests: still-polling sibling / control driver read counts instead of 300-500 ms (subscriptions x4,
alarm projection x5), structural ProbeTask==null + enabled-probe control (host probe x2), predecessor
wait (NativeAbCipLeaseReleaseTests), processed waits in the shutdown/logging tests.
AbLegacy.Tests: sibling-subscription control (Unsubscribe_halts_polling), ProbeCts==null + control.
AbCip.IntegrationTests differential safety: a post-phase control open through the same throttle instead
of 1.5-2.5 s sleeps (via a native tag init, keeping the harness read-only guard green).
Fake tag ReadCount made interlocked; CapturingLogger entries snapshotted under a lock.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
- Process-wide CipConnection statics (ForwardOpenCount, Forward Close counts, RequestsSent, exchange
stats, OpenAttempts, OpenAttemptBudget) move to an instance ConnectionDiagnostics owned by each
DeviceSessionPool (and by a stand-alone CipConnection). The open-attempt budget becomes a disposable
per-DeviceKey limit (LimitOpenAttempts); the differential harness scopes one to the press under test.
- LibplctagOrphanRelease.ForceRootingForTest is gone: ReleaseIfOrphaned(tag, canReadHandles) overload.
- A connected reply with general 0x01 / extended 0x0107 or 0x0203 (target no longer holds the class-3
connection, TCP still up) retires the session at once; the next send reopens through the throttle.
- New tests: dispose during RegisterSession, abandoned-open observer (falsified), scheduler-dispose-throws
guard (DeviceSessionPool.CloseAsync), release-in-background with a shared open in flight, per-device
limit scoping, CIP-close recycle (request + keep-alive + negative control).
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
#572: listing continues at max(instance in page)+1 (no ascending-order assumption, no-progress guard kept);
browsePageDelayMs (default 5 ms) paces pages; DiscoverAsync reads templates through one batch reader
(IAbCipTemplateReaderFactory.CreateBatch) holding one lease.
#575: differential harness reports a same-status template refusal as an equal refusal; offline test pins the
open-attempt budget without relying on the abort ending the phase.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
I1: a live verdict no longer waives the value check. Only elements that moved between the two libplctag reads are excused.
- An element equal in both libplctag reads must also be equal through native; otherwise **NO: stable element i**.
- A moved element must not read NaN or infinity on native unless libplctag saw it too; otherwise **NO: non-finite element i**.
- Live tags log their full raw bytes and every element, and the summary reports live tags as N of the total.
- The offline pin adds the pass-1 Real[5] shape: a stable element shifted on native fails. It is red with the element check disabled.
M9: after each native phase (differential and latency), wait for the session close. With AB_DIFF_COUNT_OPENS=1, assert exactly one Forward Close was sent, using the new CipConnection counters; acked is logged.
M8: each latency pass logs its GC collection deltas (gen0/1/2) for both transports, plus native per-exchange round-trip min/mean/max.
M4: the latency test also asserts that no libplctag orphan had to be rooted.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
In T21 press pass 1, two REAL tags diverged only because their live values moved
between the sequential libplctag and native phases (WW_M4ActualTemp 384.887 ->
385.138).
The libplctag phase now reads every selected tag a second time, paced, before
native starts (TransportObservations.ProbeReads). A tag whose two libplctag reads
both succeed and differ is classed live. For a live tag, parity still requires:
- the same status (and the native-TypeMismatch rule);
- no decode error;
- the same raw length;
- the same CIP type code when both sides expose one (native records it now;
libplctag.NET 1.5.2 does not);
- the same decoded shape.
Value equality is not required. Live tags get their own list and a "libplctag
probe" table column, and are counted as neither expected nor unexpected
divergences.
A tag that reads stable on libplctag but differs on native is still an unexpected
divergence, and a missing or failed probe never makes a tag live. The offline pin
A_live_value_is_compared_structurally_and_a_stable_one_by_value goes red with the
live branch disabled.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
The T21 press pass 1 test host died at exit with "A callback was made on a garbage
collected delegate of type ...plctag+callback_func_ex::Invoke". The cause is in
libplctag.NET 1.5.2. When a tag's create fails, for example with NotFound,
InitializeAsync throws with the callback still registered. Dispose() destroys a tag
only if it is initialised, so the native tag outlives its wrapper. The GC then frees
the delegate, and libplctag's atexit plc_tag_shutdown raises DESTROYED into it.
Reproduced against ab_server: the production LibplctagTagRuntime with a NotFound tag
exits 134 with that exact message, and exits 0 with this fix.
A timed-out create unregisters its callback but never destroys the handle either,
so that native tag keeps reconnecting for the life of the process.
The fix adds LibplctagOrphanRelease (AbCip and AbLegacy). After a failed
initialise/read/write that leaves the tag uninitialised, it reads the handle through
the pinned wrapper's private fields, unregisters the callback and destroys the tag.
If those fields cannot be read, it roots the tag for the life of the process
instead. It is applied in both tag runtimes, the symbol-listing reader and the
template reader. GetStatus keeps the status the tag held before it was destroyed.
Pins: offline refused-connection tests in AbCip.Tests and AbLegacy.Tests, a live
NotFound test on ab_server, and a reflection-shape pin. All go red with the release
disabled. The differential harness also asserts that no orphan had to be rooted.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
The libplctag adapters assigned Tag.Path straight from the device's parsed
CipPath. A device address with no route (ab://host:44818/ - the normal
Micro800 form, and a MicroLogix with no route) parses to "", and libplctag
rejects an empty path attribute with ErrorBadData; omitting the attribute
(null) is what it accepts. So Micro800 could not connect on the default
libplctag transport.
This predates the native transport work and exists on master.
Add an internal LibplctagPath.Normalize helper per driver project (blank ->
null) and route all four Tag constructions through it (AbCip tag runtime,
symbol-list enumerator, template reader; AbLegacy tag runtime). The runtime
tag construction is extracted to an internal BuildTag so tests can inspect
Tag.Path without connecting. Tests fail with Normalize reverted to identity.
Update the Micro800 smoke-test comment: both transports are expected to pass.
A browse-committed AB CIP / TwinCAT / FOCAS tag bound with its model's DEFAULT
data type, not the one the device reported. A browsed REAL committed as
`{"tagPath":"Pump_1_Speed","dataType":"DInt"}` — and those three drivers decode
the wire bytes by that field, not by the raw row's OPC UA DataType — so the tag
read four bytes of a float through an integer decoder and published a plausible
wrong number with no error raised anywhere. FOCAS was missed when #536 was filed.
The type is CARRIED, not derived. Reverse-mapping the leaf's driver-agnostic
DriverDataType looks like the smaller fix and is wrong: SInt/Int/DInt/USInt/UInt
all collapse into Int32 on the way out of the driver, so that version would bind
a 16-bit INT as a 32-bit DINT while appearing to fix the REAL. Drivers now state
their own type name on DriverAttributeInfo.NativeDataType, which reaches the
picker as AttributeInfo.AddressFields["dataType"] and the commit mapper from
there. A leaf that states nothing keeps the model default — the pre-#536
behaviour, kept deliberately as the fallback rather than a guess.
Numeric strings are refused before parsing: Enum.TryParse accepts "9" for any
enum and Enum.IsDefined then confirms it, so an unguarded parse would bind a tag
to a type nobody named. A test caught this in the first version of the guard.
--- and the other half, which the fixture was hiding ---
Test Connect on a device with NO authored tags — every AB CIP device at the
moment an operator first presses the button — reported "CIP handshake failed"
against a healthy controller. That was written down as a fixture limitation
("ab_server doesn't implement @raw_cpu_type"). Both halves of that were wrong:
* @raw_cpu_type is not a libplctag special tag at all (only @raw, @tags and
@udt/ are), so it goes out as an ordinary symbolic name that no controller
defines, and the controller's "tag does not exist" IS the successful answer.
* ab_server answered an unresolvable tag path with CIP 0x03 where a Logix
controller answers 0x04 — ErrorBadParam vs ErrorNotFound, which the probe
classifies oppositely. Fixed in vendored patch 0002.
* With the fixture then telling the truth, the real defect surfaced:
AbCipDriverProbe.IsReachableException matched the native C status spellings
("STATUS_NOT_FOUND"), but libplctag.NET throws with the MANAGED enum name
("ErrorNotFound"). Those substrings can never match, so the reachable
classification could not fire on the exception path — which is the path every
no-authored-tags probe takes. This was failing on real hardware too, not just
against the sim. It now recovers the Status and defers to IsReachableStatus,
so there is one classification rather than two that can drift.
Rejected: switching the fallback to @tags. libplctag builds a tag-listing tag
with NO network I/O, so it reports OK against any TCP listener — measured green
against a Mosquitto broker.
Verification: full solution suite green. Falsification runs confirm exactly the
intended tests go red — 9 for the type carry, 3 (the reachable statuses only) for
the probe classification. Live on docker-dev: browse-committed TestString/
Motor_Run/TestSINT now store String/Bool/SInt, alongside last session's
Pump_1_Speed still holding the wrong DInt. TestSINT is the falsifier — its row
DataType is Int32, identical to TestDINT's, so no reverse map could have produced
"SInt".
Known consequence: pre-existing browse-committed tags keep their wrong dataType;
the fix applies to new commits only.
Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
The AbCip controller browse could never be verified end to end: libplctag's
ab_server answers CIP service 0x55 (Get Instance Attribute List) on the Symbol
Object class with "unsupported", so the `@tags` walk had no backend. #468's own
definition of done offered a sim that serves `@tags` as an alternative to real
hardware; this is that.
The fixture now applies a vendored patch teaching ab_server to serve the Symbol
Object listing, with partial-transfer paging. Correctness is checked against
libplctag's own `list_tags_logix` rather than against our decoder — our decoder
is the thing under test, so its agreement would prove nothing. The clone is also
pinned to a concrete tag: the Dockerfile called `--branch release` "pinned" while
tracking a branch that moves.
That immediately exposed a real defect. CipSymbolObjectDecoder advanced to an
even byte boundary after each symbol name, but entries are packed with no
padding — libplctag walks them by sizeof(entry) + string_len, and a captured
reply confirms it. Any odd-length name therefore desynchronised every entry
behind it, and odd-length names are ordinary. In the live browse below,
`Motor_Run` is 9 bytes and first on the wire, so the old decoder would have
shown that one tag and silently dropped the other eight.
Every existing multi-entry test passed throughout, because the test builder
padded exactly as the decoder did: the two agreed with each other and neither
agreed with a controller. The builder no longer pads, and the layout is pinned
by a captured reply (CipSymbolObjectWireCaptureTests) instead of by a second
statement of the assumption. Restoring the alignment step reddens exactly the
three new tests and none of the 29 others.
Live gate on docker-dev, all three of #468's criteria:
- populated tree — all nine seeded tags render as leaves, in wire order
- refresh re-captures
- leaf commit — Pump_1_Speed + TestDINT saved with their CIP tag paths
The gate also surfaced two things it was not asked about: browse-commit drops
the discovered data type, so a browsed REAL commits as a DINT and the driver
decodes it as one (filed as #536), and Test Connect fails against this fixture
regardless of the device because it probes `@raw_cpu_type` (documented).
TwinCAT and FOCAS still have no browsable backend; #468's AbCip half is closed,
theirs is not.
Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
Replace pre-declared options.Tags (typed <Driver>TagDefinition lists) with
options.RawTags (IReadOnlyList<RawTagEntry>) across all 6 Docker-gated driver
integration suites so they COMPILE against the v3 driver API.
Each project gets a local <Driver>RawTags helper mirroring the unit-test
project's helper: it serialises a typed def back to its TagConfig blob via the
driver's <Driver>TagDefinitionFactory.ToTagConfig and packages it as a
RawTagEntry (RawPath = def.Name; DeviceName = def.DeviceHostAddress for the
multi-device drivers AbCip/AbLegacy/TwinCAT/FOCAS). Test intent (addresses,
data types, device routing, assertions) is unchanged — only the
tag-authoring/config-delivery shape was migrated.
Docker-gated: these still skip at runtime without fixtures; COMPILE is the gate.
KnownProfiles.All used a { get; } = [...] initialiser declared textually
before the static readonly profile fields it references, so C# static-init
order captured an all-null list. ForFamily() then NRE'd on p.Family, faulting
AbServerFixture..ctor and blocking the whole AbCip.IntegrationTests suite.
Expression-body it so it evaluates on access, after the fields are set.
Live-verified against the controllogix fixture: suite goes 6F/1P/3skip ->
10 pass / 0 fail / 3 skip (skips = emulator-mode tests).
Integration-sweep follow-up #1 (archreview/plans/INTEGRATION-SWEEP-STATUS.md).
Inject the custom UnwrappedCapabilityCallAnalyzer as an OutputItemType=Analyzer
ProjectReference from Directory.Build.props (excluding the analyzer + its test
project) so OTOPCUA0001 runs on every src/ and tests/ compilation — it previously
enforced its CapabilityInvoker-wrapping rule against nothing but its own 31 unit
tests (the 'built-but-never-wired' failure mode).
Triage of the ~280 surfaced hits, three categories:
1. RESILIENCE-DISPATCH-GAP (7 sites, DriverInstanceActor x6 + GenericDriverNodeManager
x1): a REAL, previously-untracked gap the analyzer caught on first wiring — the
Phase 6.1 CapabilityInvoker resilience pipeline (retry/breaker/bulkhead/telemetry)
is constructed ONLY in tests and was never wired into the production dispatch
layer. Scoped per-site #pragma with a greppable RESILIENCE-DISPATCH-GAP marker
explicitly noting these are tracked-but-not-intentional, pending the dispatch-wiring
remediation (filed as a follow-up). Keeps the analyzer live everywhere else in
those projects so a NEW unwrapped call still fails the build.
2. Driver-INTERNAL self-calls (3 sites, AbCipAlarmProjection x2 + S7Driver x1):
a driver's own poll/ack path calling its own capability method. The invoker wraps
the driver from the dispatch layer OUTWARD; a driver re-wrapping its own internal
calls would double-wrap. Genuinely intentional — scoped #pragma with that rationale.
3. Wire-level test suites + manual-testing CLIs (12 projects): invoke drivers directly
by design — the analyzer's own documented intentional case. Project-level NoWarn
with a comment.
Verified: full solution build green, 0 OTOPCUA0001 hits; analyzer's 31 tests pass;
negative control — dropping one dispatch-gap pragma re-fires OTOPCUA0001 and fails
the Runtime build, proving the analyzer is genuinely live tree-wide, not disabled.
Add AbCipEmulateNestedUdtTests (skip-gated, AB_SERVER_PROFILE=emulate) to close
the live-gate gap for nested-struct UDT discovery via CIP Template Object (class 0x6C)
threaded by commits 3d8ce4e8/d203f31c. Compiles + skips cleanly against ab_server
(no CIP Template Object service). Update docs/drivers/AbCip.md nested-struct section
to record the shipped decode path, the Emulate-only live-gate, and offline unit coverage.
All five suppressed advisories are now resolved at baseline/resolved versions,
so every NuGetAuditSuppress is removed repo-wide:
- System.Security.Cryptography.Xml (GHSA-37gx-xxp4-5rgx / GHSA-w3x6-4m5h-cxqf)
-> fixed by the .NET 10 baseline (10.0.6)
- OPCFoundation Opc.Ua.Core (GHSA-h958-fxgg-g7w3) -> fixed at resolved 1.5.378.106
Two were still live and are now patched via direct security pins:
- OpenTelemetry.Api 1.9.0 -> 1.15.3 (GHSA-g94r-2vxg-569j) pinned in Cluster;
Runtime/ControlPlane/AdminUI + tests inherit via project reference
- Tmds.DBus.Protocol 0.20.0 -> 0.21.3 (GHSA-xrw6-gwf8-vvr9) pinned in Client.UI
Also correct the Historian sidecar runtime comments (x86 -> x64, matching the
csproj PlatformTarget). Solution audit: 0 vulnerable packages; full build clean.
Adds <summary>, <param>, <typeparam>, and <inheritdoc/> tags to public
members surfaced by commentchecker — resolves 5,847 of 5,869 issues
(99.6%) across three /fixdocs passes.
Adds Directory.Packages.props (ManagePackageVersionsCentrally) and
Directory.Build.props (net10.0/nullable/implicit usings/LangVersion latest).
Strips Version attributes from every csproj PackageReference and consolidates
versions into the central file.
Side fixes (necessary to keep the build green on .NET SDK 10.0.105 on macOS):
- Microsoft.CodeAnalysis.CSharp{,.Workspaces}: 5.3.0 -> 5.0.0. The 5.3.0
analyzer DLL references compiler 5.3.0.0 and the local SDK ships compiler
5.0.0.0, producing CS9057 on every project that loaded the Analyzers
output. Master itself was broken on this machine pre-change.
- Server + Server.Tests pin OPCFoundation.NetStandard.Opc.Ua.{Configuration,
Client} to 1.5.374.126 via VersionOverride, matching Opc.Ua.Server's
pin. Mixing 1.5.378.106 Opc.Ua.Core transitively with 1.5.374.126
Opc.Ua.Server breaks CustomNodeManager2 override signatures
(CS0115 on LoadPredefinedNodes/Browse/HistoryRead*) and CS7069 in
the tests. The pin disappears when the legacy Server project is
deleted in Task 56.
- Client.UI + Client.UI.Tests: NuGetAuditSuppress for
GHSA-xrw6-gwf8-vvr9 (Tmds.DBus.Protocol 0.20.0 reaches both projects
transitively from Avalonia.Desktop on Linux/macOS only).
Deviation from the plan: TreatWarningsAsErrors=true is NOT set in
Directory.Build.props because the pre-v2 Admin/Server test projects carry
~240 xUnit1051 analyzer warnings that would fail the build. New v2 projects
opt in via their own csproj; the global flag can return once the legacy
projects are deleted in Task 56.
UnsTabDragDropE2ETests were timing out at the 'UNS Structure' nav-link
locator because AdminWebAppFactory never registered AdminHubConnectionFactory
/ HubTokenService / DataProtection — ClusterDetail.razor's @inject threw at
circuit boot, so the page never advanced past the Loading placeholder. 2 → 3
pass after the registrations land. Also documents the Modbus standard-vs-
exception_injection coverage matrix in the fixture README + cross-references
docs/drivers/AbServer-Test-Fixture.md from each Emulate test so a developer
landing on a skipped test has a direct doc pointer.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Two real bugs uncovered by re-running with the new fixture defaults
pointing at the shared docker host. Both are test-side, not driver-side.
AbCip — Driver_reads_seeded_DInt_from_ab_server (4 parametrized rows):
Hardcoded 'ab://127.0.0.1:{port}/1,0' in the deviceUri instead of
the resolved fixture.Host. The new 10.100.0.35 default (and any
AB_SERVER_ENDPOINT override) silently couldn't reach this test —
the driver tried to connect to a non-existent localhost:44818 and
returned BadCommunicationError on all 4 profile rows. The sibling
Emulate tests already use the fixture's resolved endpoint; this
smoke test was missed in the original migration.
Fix: deviceUri = $"ab://{fixture.Host}:{fixture.Port}/1,0".
Modbus — Float32_With_CDAB_Roundtrips_Through_Wire:
Test wrote a Float32 to HR 100 (2 consecutive registers: 100+101).
standard.json's writable HR range declares [100,100] only — a
single-cell auto-incrementing register, not a 2-register pair. The
write to register 101 was rejected with Illegal Data Address
(BadOutOfRange).
Fix: moved the tag from HR 100 to HR 200 (in standard.json's
'[200, 209]' scratch range — 10 consecutive writable HRs). The
Float32+CDAB semantic the test exercises is unchanged.
Modbus — Block_Read_Coalescing_Reduces_PDU_Count_End_To_End:
Test read HR 300, 302, 304 — outside both the writable ranges and
the uint16 seed list. pymodbus rejects reads to unseeded HRs even
though 'hr size' is 2048. BadOutOfRange on every read.
Fix: moved the tags from 300/302/304 to 200/202/204 (within the
scratch range). The non-contiguous coalescing semantic (3 tags
inside a 5-register window with MaxReadGap=5) is preserved.
After this commit:
- Modbus.IntegrationTests: 6/38 pass / 32 skip / 0 fail
(was 4 pass / 32 skip / 2 fail; 32 skips are profile-gated
ExceptionInjectionTests — they need MODBUS_SIM_PROFILE=
exception_injection and a different container, intentional gating)
- AbCip.IntegrationTests: 10/12 pass / 2 skip / 0 fail
(was 6 pass / 2 skip / 4 fail; 2 skips are Emulate tests that
need the fixture for separate scenarios)
No driver code changed.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
CLAUDE.md "Docker Workflow" claims (per the 2026-04-28 migration note)
that all fixture-class default endpoints were rewritten to target the
shared Docker host at 10.100.0.35. Audit during today's e2e run showed
the claim was incomplete — five fixture classes still defaulted to
localhost / 127.0.0.1, causing every fixture-touching integration test
to skip with "endpoint unreachable" on a fresh box that hadn't set
the override env vars.
Files corrected:
- tests/.../Modbus.IntegrationTests/ModbusSimulatorFixture.cs
DefaultEndpoint: localhost:5020 → 10.100.0.35:5020
- tests/.../S7.IntegrationTests/Snap7ServerFixture.cs
DefaultEndpoint: localhost:1102 → 10.100.0.35:1102
- tests/.../OpcUaClient.IntegrationTests/OpcPlcFixture.cs
DefaultEndpoint: opc.tcp://localhost:50000 → opc.tcp://10.100.0.35:50000
- tests/.../AbCip.IntegrationTests/AbServerFixture.cs
Host default + ResolveHost fallback: 127.0.0.1 → 10.100.0.35
- tests/.../AbLegacy.IntegrationTests/AbLegacyServerFixture.cs
Host default + ResolveEndpoint fallback: 127.0.0.1 → 10.100.0.35
XML doc comments referencing the old localhost defaults were updated in
the same pass so the class-summary documentation matches the actual
default. The override-via-env-var mechanism (MODBUS_SIM_ENDPOINT,
AB_SERVER_ENDPOINT, AB_LEGACY_ENDPOINT, S7_SIM_ENDPOINT,
OPCUA_SIM_ENDPOINT) is unchanged — pointing at a real PLC or a
locally-running container still works exactly as before.
Verification:
- Solution-wide dotnet build: 0 errors.
- S7.IntegrationTests: 3/3 pass without env-var override.
- OpcUaClient.IntegrationTests: 3/3 pass without env-var override.
- Modbus.IntegrationTests: 4/38 (same as the env-var-override run —
the 2 failures + 32 skips are pre-existing fixture-profile
mismatches unrelated to this fix).
- AbCip.IntegrationTests / AbLegacy.IntegrationTests: same results
as the env-var-override run.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Rewrite src/ and tests/ project paths in docs, CLAUDE.md, README.md, and
test-fixture READMEs to the new module-folder layout (Core/Server/Drivers/
Client/Tooling). References to retired v1 projects (Galaxy.Host/Proxy/Shared,
the legacy monolithic test projects) are left untouched.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Group all 69 projects into category subfolders under src/ and tests/ so the
Rider Solution Explorer mirrors the module structure. Folders: Core, Server,
Drivers (with a nested Driver CLIs subfolder), Client, Tooling.
- Move every project folder on disk with git mv (history preserved as renames).
- Recompute relative paths in 57 .csproj files: cross-category ProjectReferences,
the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external
mxaccessgw refs in Driver.Galaxy and its test project.
- Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders.
- Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL,
integration, install).
Build green (0 errors); unit tests pass. Docs left for a separate pass.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>