M1: the time-weighted family (incl. Total, formerly a pushed-down SUM) streams
raw window rows into the C# evaluator. New shared knob
ServerHistorian:MaxTimeWeightedRawRows (default 1,000,000; <=0 unbounded with a
Validate warning) flows through HistorianBackendRegistry into both providers.
The window query is capped at cap+1 (SQL Server TOP (@maxRows), QuestDB LIMIT $4);
one row past the cap throws the new Core.Abstractions
HistoryReadLimitExceededException, which the node manager maps to
BadTooManyOperations for that node. Not counted as a backend health failure;
bound rows are not counted; per-sample aggregates are not capped.
M2: reverse Interpolative is anchored at the later time (Part 13): points at
End - i*interval, emitted latest first. 10:00->09:00 @1h yields 10:00.
L1: Partial bit (0x4, = Opc.Ua.AggregateBits.Partial) on non-Bad results of a
truncated last interval (time-weighted family; per-sample family is a follow-up).
L2/L3: aligned with the SDK AggregateCalculator.GetTimeBasedStatusCode
(decompiled from Opc.Ua.Server 1.5.378.106): TreatUncertainAsBad=false counts
Uncertain time (Uncertain samples, held-into-outage, extrapolation) as Good
time; data but no non-Bad time => generic Bad (0x80000000); BadNoData only
when there is no data at all. Consequence: a live tag's latest interval reads
Good (documented).
L5: release note no longer claims Total matches the Gateway Integral exactly
(AVEVA's divisor is unverified); it notes Total is now evaluated in C# and
subject to the cap.
Tests: unit (reverse Interpolative x3, Partial, Bad vs BadNoData incl. an
open-ended outage, cap helpers, SDK bit oracles); conformance (reverse
Interpolative, raw-row cap at/over/0, bounds not counted, health unaffected);
node manager BadTooManyOperations; options default + warning. Each new
behaviour falsified by mutation (aggregator x9, data-source cap checks on
both backends against the real DBs, node-manager catch).
New AggregateFamily.TimeWeighted serving TimeAverage, TimeAverage2, Total,
Total2 and Interpolative, evaluated by the shared Sql.Common
TimeWeightedAggregator for both SQL backends (identical results by
construction). HistoryAggregateType gains TimeAverage2 + Total2 (appended);
OtOpcUaNodeManager.MapAggregate maps their NodeIds. Gateway's mapper already
refuses unknown defined members => BadAggregateNotSupported per node.
Semantics (server defaults, client AggregateConfiguration ignored):
TreatUncertainAsBad=false, PercentDataBad=PercentDataGood=100,
UseSlopedExtrapolation=false. Sloped for Double/Int64, stepped for Boolean;
a usable sample followed by a Bad one is held up to the outage (AtTime rule);
stepped Uncertain extrapolation past the last sample. TimeAverage/Total use
interpolated bounding (bridge outages); TimeAverage2/Total2 exclude Bad time.
Bounding values: latest usable + latest any before start, first any + first
usable at/after end (four TOP 1 / LIMIT 1 seeks).
CLIENT-VISIBLE: Total on SqlServer/QuestDb was SUM of samples; it is now the
time-weighted integral (TimeAverage x interval seconds), matching Gateway's
Integral. Release note in docs/Historian.md.
Trade-off (deviation from the preferred hybrid pushdown, allowed by the
design): the time-weighted family is NOT pushed down. Each read streams the
window's rows plus the four bounds (SQL Server: one five-result-set batch;
QuestDB: bounds UNION ALL + window select) into the C# evaluator. Network is
O(samples in window), memory O(buckets). Writing the per-segment
interpolation/edge splitting twice in two SQL dialects and keeping them
bit-identical was judged the bigger risk; this also makes the QuestDB
lag/lead spike moot.
Tests: 35 hand-computed TimeWeightedAggregator unit cases (each of 10
implementation mutations goes red); served-aggregate pin 13 -> 17;
conformance sparse fixture (intervals wider and narrower than sample gaps)
+ an outage straddling both window edges (each of the four SQL seeks
disabled in turn goes red); node-manager NodeId mapping test.
IHistorianDataSource.TimestampResolutionTicks (default 1; QuestDB 10). A drained tie
cluster now steps off T by the resolution, so a forward one-value-per-page read on a
microsecond backend no longer re-reads the same sample forever (C1). QuestDB AtTime
results carry the client's original request time (M3); regression for the NEXT seek
skipping a tombstone (M1). Conformance backend wires the real writer and updater.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
- OtOpcUaNodeManager overrides HistoryUpdateData / HistoryDeleteRawModified / HistoryDeleteAtTime,
block-bridging to the optional IHistorianDataUpdater under the shared HistoryRead batch limiter +
deadline. Insert/Replace/Update map to HistoryUpdateMode; Remove, IsDeleteModified, events and
structure data are BadHistoryOperationUnsupported. Per-item codes stitched back in request order
(MinValue SourceTimestamp => BadInvalidTimestamp, untypeable value => BadTypeMismatch); success
clears the base's pre-seeded Unsupported error.
- HistoryWrite AccessLevel bit OR-ed in for historized nodes when an updater is wired (raw + UNS);
it is dispatch-load-bearing in the SDK base. OtOpcUaSdkServer.SetHistorianDataUpdater; the hosted
service assigns it from an optional HistorianUpdaterHolder before SetSink, clears it on stop.
- AuthorizeHistoryUpdate: ACL on => scoped OpcUaOperation.HistoryUpdate decision (replaces the role
check); ACL off => #563 key re-check + new OpcUaDataPlaneRoles.HistoryUpdate role, conferred by
ApiKeyInterimRoleMapper only from a Cluster-scoped HistoryUpdate grant (WriteOperate does not).
- AdminUI ACL editor offers NodePermissions.HistoryUpdate.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
Since #516 a DriverConfig change is stop + respawn, so DriverSpawnPlan.ToApplyDelta
was always empty and the in-place path had no producer. #663 and #664 were both
latent bugs in it. This deletes it:
- host: ApplyChildDelta, _pendingDelta, HandleApplyResult and HandleDeltaApplied
- plan: DriverSpawnPlan.ToApplyDelta
- actor: the ApplyDelta, ApplyResult and DeltaApplied messages, the Connected
reinit handler and the mid-connect AdoptConfigDuringInit
- tests: the actor tests that drove the seam
IDriver.ReinitializeAsync and each driver's implementation and unit tests stay.
Comments and docs that cited AdoptConfigDuringInit as the reason a driver must
release prior state at init now cite the IDriver contract and overlapping
retries, which still apply.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
After an OpcUaClient respawn an upstream inactive+unacked condition went out as
Retrigger+Clear (duplicate Activated+Cleared rows, Active flicker), and a
first-sight inactive+acked one as Unspecified (an Activated row for an inactive
alarm; a retained-Active host condition never cleared).
- New AlarmTransitionKind.InactiveUnacknowledged: one projection, rows only for
what changed (Activated+Cleared from acked, Cleared from active+unacked, none
when already inactive+unacked).
- OpcUaClient uses it for moves into inactive+unacked; first sight of an
inactive condition is InactiveUnacknowledged or Clear+Acknowledge, flagged.
- Projector: a flagged Acknowledge on an already-acked condition writes no row.
- E2E tests through DriverHostActor.ForwardNativeAlarm (red-proven).
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
- AlarmTransitionKind.ActiveAcknowledged (appended): active AND acked applied as ONE projection.
Galaxy ActiveAcked snapshot entries and OpcUaClient inactive->(active,acked) use it; the
projector writes 'Activated' only if not already active, 'Acknowledged' only if not acked.
- AlarmEventArgs.IsRestatement (optional, default false): set only by Galaxy snapshot entries
and OpcUaClient first sight. A flagged Retrigger on an Active+unacked condition with the same
message and severity, or a flagged Clear on an inactive condition, writes no /alerts row.
- NativeAlarmProjector reports the history rows per transition; ForwardNativeAlarm writes one
row per entry. Unflagged sources (FOCAS/MTConnect/AbCip, live Galaxy) are unchanged.
- Tests: projector rules each with a must-write control; OpcUaClient transition table;
Galaxy feed/driver mapping; Galaxy + OpcUaClient end-to-end through DriverHostActor.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
HistoryRead is served server-side by IHistorianDataSource; nothing ever dispatched
to a driver's IHistoryProvider. Removes IHistoryProvider, the OpcUaClient history
passthrough, DriverCapability.HistoryRead (+ resilience tier rows and AdminUI row),
HistoryReadStatusException and its node-manager catches, and the tests that only
covered them. Shared result types and HistoryAggregateNotSupportedException stay
(moved to Historian/HistoryReadContracts.cs). A stored ResilienceConfig still
carrying a HistoryRead key parses (diagnostic only; new test).
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
60 s labelled a slow-but-clean large rebuild degraded. The deadline moves to a
shared Commons DeployTimings constant that ConfigPublishCoordinator reads, and
the node's timeout is deadline - 15 s margin, so the held ack still lands in
time. A timed-out ack's reason now says the outcome was not reported in time,
distinct from a real sink failure.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
The apply writes the node's row Applied/null before the address-space outcome
is known; central adds the reason only when it ACCEPTS the ack, so a discarded
(stale/timed-out) ack left a fused node's row reading clean. The prefix moves
to ApplyAck.DegradedReasonPrefix so both writers spell the row identically.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
ApplyAck gains trailing Degraded/DegradedReason (defaulted, so an old node's
DPS JSON or gRPC ack decodes exactly as before). mesh_transport.proto adds
ApplyAckMessage.degraded = 6 / optional degraded_reason = 7. OpcUaPublishActor
replies RebuildCompleted(Degraded, Reason) on every handler path when the
RebuildAddressSpace carries ReportOutcome.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
A full RebuildAddressSpace recreated every native Part 9 condition inactive +
acknowledged, and when the alarm-tag set was unchanged (e.g. one
UnsTagReference added to an alarm-bearing raw tag) nothing re-told the new node
its state: the host does not re-subscribe for an unchanged set, and Galaxy /
OpcUaClient have no snapshot to replay anyway. Active alarms read normal until
their next device transition.
OtOpcUaNodeManager now captures each NATIVE condition's live state (from the
node, so a client-applied ack is kept) before the rebuild clears, restores it
when the same id is re-materialised native in the same apply, and reports ONE
condition event per restored off-normal condition at the new
IOpcUaAddressSpaceSink.CompleteAddressSpaceApply (after notifier wiring).
Unclaimed captures are discarded there, so a later re-add is fresh. Quality is
carried silently for normal conditions too (it is only re-annotated on a
connectivity edge). Scripted conditions are untouched (#487 re-asserts them).
OpcUaPublishActor calls CompleteAddressSpaceApply at the end of every apply.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
AlarmEventArgs gains optional OpcUaSeverity (supersedes the four-bucket mapping, clamped
1..1000) and QualityStatusCode (projected onto the condition's Quality). An Unspecified-kind
event carrying a quality is a quality-only annotation: the host updates the condition but
publishes no alerts row. Both default null, so every existing native source is unchanged.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
DriverHostActor.StopChild released the tracker (Invalidate) and evicted the hub synchronously, but
Context.Stop is asynchronous: the stopping child's in-flight SubscribeBulk completed through its
capability invoker AFTER the release, and its RecordCallStart/RecordSuccess/RecordCallComplete
re-created the tracker entry, which DriverResilienceStatusPublisherService then re-emitted every tick
forever. Confirmed with a temporary stack capture in the tracker (removed): every post-Release write
came from DriverInstanceActor.HandleSubscribeAsync -> CapabilityInvoker.ExecuteAsync; the test failed
whenever it landed before the second publisher tick.
- DriverResilienceStatusTracker.Retire (Release) drops the id's snapshots and ignores every later
Record* for it; one guarded write path re-checks after the upsert so a write racing Retire cannot
survive it. Reinstate (called by DriverCapabilityInvokerFactory.Create) lifts it, so the same id
re-added in a later deployment records again.
- TelemetryLocalHub.Evict now also holds the id (late Health/Resilience dropped, neither cached nor
fanned out); ITelemetryLocalHub.Readmit (default no-op), called at the top of SpawnChild, lifts it.
- The removal test is now deterministic: an invoker decorator holds the child's subscribe inside the
real invoker's bracket across the removal and signals when its late writes are done (positive
control) — red 5/5 without the fix, green 20/20 with it. New unit tests for the tracker guard
(incl. a Retire race), the factory Release/Create pair, the hub hold/readmit, and a re-add-same-id
host test.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
MAJOR-1: R4's exact element-type match refused ScadaBridge's CLR-list
writes (its element types are only Boolean/Int32/Float/Double/String/
DateTime) to every Int16/UInt16/Byte/UInt32/Int64/UInt64 array node and a
Double list to a Float array. EvaluateEquipmentWriteStructure now converts
a numeric array of another numeric element type element-wise, CHECKED, into
the node's element type and hands the converted array back through
OnEquipmentTagWrite's ref value, so the node stores and the driver receives
the node's own type. Any out-of-range, fractional-to-integer, NaN/Inf-to-
integer or Float-overflowing element refuses the whole write BadTypeMismatch
(nothing dispatched) - so the UInt32 -> Int32 bit reinterpretation stays
closed. Non-numeric mismatches stay refused. The wrong 'no client relies on
a looser rule' comment is corrected.
MINOR-1: the array-value-to-scalar-node refusal broke writes back to
browse-committed array tags (committed scalar, isArray never set) on
pass-through drivers. It now applies only when the owning driver's scalar
encoder cannot take an array (DriverArrayWriteSupport.
RefusesArrayValueOnScalarTag: Modbus, S7), carried RawTagPlan.
ScalarRefusesArrayValue / UnsReferenceVariable.BackingScalarRefusesArrayValue
-> EnsureVariable(refuseArrayOnScalar) -> a per-node set in the node
manager. OpcUaClient/Galaxy/others keep pre-#610 dispatch. Not on the
classifier whitelist (driver-type edit rebuilds); a mirror whose flag
changes is recreated, not updated in place.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
MAJOR-1: the SDK skips TypeInfo.IsInstanceOfDataType on any node with an
OnWriteValue handler (every writable equipment node), and the node manager's
fail-fast treated numeric<->numeric as compatible, so a UInt32[] to a Galaxy
Int32 array matched MxValueEncoder's int[] arm by CLR covariance and was
written bit-reinterpreted with a Good result. EvaluateEquipmentWriteStructure
now matches an ARRAY write's element type exactly (Byte[]/ByteString the only
equivalence; Variant[]/object[] refused) -> BadTypeMismatch, nothing
dispatched. MxValueEncoder's int[]/long[] arms are exact-type guarded too, and
the Galaxy parity test's false "the SDK refuses" premise is corrected (the
UInt32/UInt64 exclusion is now the encoder's own answer). Scalar writes keep
numeric widening by decision: consumers write CLR-typed values (Double to a
Float node) and every driver's scalar encoder range-checks.
MINOR: Modbus row honours maxRegistersPerWrite (smallest of DriverConfig /
the tag's DeviceConfig, default 123) and FC15's 1968-coil ceiling, and
requires region + numeric address; Modbus/S7/Galaxy require isArray + integer
arrayLength >= 1 (Galaxy: an unbounded node would let a short write resize the
attribute); an array value to a scalar node is refused inline. Docs: Uns.md
array-write rules + upgrade note (ReadWrite array tags become client-writable
on first boot), Modbus.md, Galaxy.md.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
Review R1:
- M1 (#609): DriverHostActor.StopChild releases the instance's resilience state before evicting the hub.
- m2 (#597): DriverHostActor publishes ShouldServiceAsPrimary() to IDriverPrimaryRoleSource at start and on
cluster membership changes (deduped), so the native-ack gate denies in a pair's boot window.
- m4 (#601): ApplyCachedArtifact returns false on empty/malformed bytes; the cached revision is not adopted,
Direct mode goes Stale (no RUNNING FROM CACHE), FetchAndCache lands Steady-with-no-revision and a
re-dispatch of the same revision really applies.
- m3 (#603): LocalDbReplicationPolicy splits into CapturesChanges (PeerAddress||ApiKey, registration) and
SharesRowsWithPeer (ApiKey && (PeerAddress||SyncListenPort>0), alarm drain gate).
- m5 (#618): Program.cs catch-all filters HostAbortedException (design-time tooling).
- m6 (Cluster-002): ClusterRoleInfo seeds only Up/WeaklyUp members.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
Review R1 M2: since #597 the SDK timer fires at real expiry, and OnTimedUnshelve routed an operator-style
Unshelve by 'system' from both pair nodes, pre-empting the engine's AutoUnshelve. The engine owns expiry,
so the callback now routes nothing. Integration test: an engine stand-in that acts on a routed Unshelve and
expires late, plus a wrapped OnTimedUnshelve (positive control: the SDK timer fired).
Review R1 m1: Part9StateMachine.ApplyAcknowledge records a commented re-ack as AddComment (persisted and
replicated) instead of a NoOp; an uncommented re-ack is still a no-op.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
Review R1 M1: StopChild evicted the hub cache, but DriverResilienceStatusPublisherService re-emits the
tracker every tick. IDriverCapabilityInvokerFactory.Release (default no-op) now invalidates the pipeline
builder + status tracker; the host calls it before Evict. Test runs a publisher tick after removal, with a
neighbour instance as positive control.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
Array nodes were forced read-only for every driver. A new single authority,
Core.Abstractions DriverArrayWriteSupport, says which (driver, element type)
pairs encode a whole-array write: Modbus (Coils / numeric HoldingRegisters),
S7 (Byte/Int16/UInt16/Int32/UInt32/Float32), OpcUaClient (pass-through) and
Galaxy (Boolean/Int32/Int64/Float/Double/String/DateTime). Everything else
stays read-only, so the server never advertises a write the driver refuses.
- Composer derives RawTagPlan.ArrayWritable + UnsReferenceVariable
.BackingArrayWritable at compose time (both seams, byte-parity); the
applier's one writability rule is Writable && (!IsArray || ArrayWritable)
for materialise and surgical paths, raw and UNS alike.
- ArrayWritable is on the classifier's surgical raw-tag whitelist and
mirrored on the UNS record (UnsReferenceBackingParityTests updated).
- Node manager refuses a wrong-length / non-array value on an array node
(BadTypeMismatch) and any IndexRange write (BadWriteNotSupported) inline,
before dispatch; WriteOperate/ACL gates and the revert are unchanged.
- Per-driver parity tests pin the table against the real Modbus write path,
S7 EncodeArrayBlock and Galaxy MxValueEncoder (UInt32/UInt64 excluded:
array covariance reinterprets their bits).
- Over-the-wire proof in OpcUaServer.IntegrationTests (ArrayWriteWireTests).
- ValueRank > 1 documented as out of scope by decision (docs/Uns.md).
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
- Native-condition Acknowledge on a non-Primary node returns BadInvalidState (nothing
routed/applied/reported) via NativeAlarmAckPrimaryGate, fed from
IDriverPrimaryRoleSource by OtOpcUaServerHostedService.
- A re-ack carrying a comment reports one comment event (Acked/Confirmed unchanged).
- TimedShelve applies its requested duration and the scripted projection carries
UnshelveAtUtc, so ShelvingState/UnshelveTime counts down instead of ~24.8 days.
- Native re-ack still routed to the driver (deliberate: documented retry path), pinned.
- AdminUI /alerts client ack/shelve path test; docs/AlarmTracking.md decisions incl.
accepted SDK EventsMonitored residual (item 6).
- Also #599/03/S20: RemoveEquipmentSubtree severs inverse Organizes edges.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
ClusterRoleInfo resolved the leader address through Cluster.State.Members, which is
published asynchronously; a miss stored null permanently, so RoleLeader(role) stayed null
(flaky test timed out under load: 6/10 failing with CPU contention, 0/20 after). Only the
address is ever read, so store it directly. Adds a deterministic unit test (fails without
the fix) and InternalsVisibleTo for the Cluster.Tests project.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
options.Roles is unconditionally overwritten by AddOtOpcUaCluster's PostConfigure to equal
EffectiveRoles.Gossiped (T2's own structural-identity fix), so comparing options.Roles against
Gossiped could never observe a divergence — an overlay setting Cluster:Roles was silently
ignored, not fail-start. The validator now injects IConfiguration and re-reads the raw
Cluster:Roles section LIVE (reflecting any overlay applied after EffectiveRoles was first
resolved), normalized through EffectiveRoles.Resolve for reuse of its own validation.
AddOtOpcUaCluster now TryAddSingleton(configuration) so a bare ServiceCollection test harness
(not just WebApplicationBuilder) can supply IConfiguration to the validator.
Both guard tests rewritten to go through the real AddOtOpcUaCluster + PostConfigure pipeline
over a live ConfigurationManager, simulating an overlay as a second provider added AFTER
EffectiveRoles was resolved off the same object — exactly Program.cs's own sequencing. Confirmed
red beforehand: the "changes" test failed to throw against the pre-fix validator.