#570
- STRING: the built-in 88-byte Logix STRING holds 82 characters (LEN + DATA[82] + 2 pad), not 84; the
write still sends the whole 88-byte structure and a read never decodes the pad as characters.
- Mistype churn: a type refusal (CIP 0xFF/0x2107) on the existence read no longer throws from
InitializeAsync, so the runtime is not disposed/re-created (and re-Forward-Opened) every poll; the driver
also keeps a runtime that throws TypeMismatch from init and records the device as reachable.
- Malformed tag name: a TagPath that does not parse, or a name the CIP symbolic encoder refuses (now also
non-ASCII, empty member, >255-char member, unterminated subscript), is AbCipTagConfigurationException ->
per-tag BadConfigurationError (named const in AbCipStatusMapper), warned once, never feeding the device
backoff or health; siblings keep reading. A malformed probe tag no longer feeds the backoff either.
- Micro800 BYTE/WORD/LWORD (0xD1/0xD2/0xD4) are type-checked as integers of their width: REAL/LREAL or a
narrower integer over LWORD is TypeMismatch, not decoded garbage.
#579
- ConnectionLease.ReleaseInBackground: one non-blocking release shape for both native AB runtimes. The
AbCip runtime's Dispose no longer waits up to 2 s under the per-tag lock; the pool still registers the
close synchronously so a re-create cannot overlap it. Offline soak tests (25 cycles, AbCip + AbLegacy)
prove no leaked connection; FakeEipServer gains OpenConnections.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
HandleOf cast the reflected nativeTagHandle with (int) and was called
inside the runtimes' catch blocks, so a libplctag bump that retyped the
field would replace every create failure with an InvalidCastException.
The field is now accepted only if it is still an int (otherwise
CanReadHandles is false and orphans are rooted), and HandleOf never
throws. Both projects pin the field type explicitly.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
On a wire the native PCCC path is proven only for N-file reads/writes and
one F8 read (ab_server). An absent transport key now resolves to Libplctag
for every family; explicit Native still wins and still warns once per
instance on PLC-5/LogixPccc. AdminUI dropdown, CLI help, evidence claims
(PcccFileType, AbLegacy.md wire-evidence table, release note) corrected:
S:0 (default probe) and B/T/C/R/S/L/ST/A/O/I are unverified natively.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
Native is the default, so a locally refused write must not look like a comms fault.
- AbLegacy: an AbTransportException with AbStatus.Unsupported (status-bit sub-element writes, PLC-5
non-N reads, all PLC-5 writes; libplctag's ErrorUnsupported maps here too) now returns
BadNotSupported on both the read and the write path (incl. the bit-RMW path). The tag handle is
not evicted and driver health is not touched. A native runtime whose init read is refused locally
is CACHED rather than disposed, so a poll of a refused tag does not re-create (and re-lease the
pooled connection) every cycle.
- AbCip: the same mapping on the write path and both read paths (single + whole-UDT).
- Uses the existing named BadNotSupported constants (StatusCodeParityTests guard).
- Tests (falsified by disabling the mapping, and separately the keep-on-refusal): status-bit
writes and PLC-5 read/write through the driver over the native runtime — BadNotSupported, zero
wire requests, one create, health unchanged; AbCip refused read/write via a refusing fake plus a
control that a non-refusal failure still evicts and degrades.
- Docs/CLAUDE.md: BadNotSupported; #571 known-gap wording removed.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
- I1: the upgrade restart itself moves every no-key AbCip/AbLegacy driver to Native (every process
start constructs drivers, incl. boot-from-cache). Docs + CLAUDE.md now say so and tell operators
to set "transport": "Libplctag" BEFORE upgrading (older builds ignore the unknown key).
- I2: AbLegacy release note leads with the status-bit write refusal (T4:0.DN, C5:0.CU, R6:0.EN, ...)
on defaulted SLC/MicroLogix drivers and the fallback. The real client status is
BadCommunicationError, not BadNotSupported (the driver's write catch-all maps the runtime's
AbTransportException like any transport failure, as #571 does for PLC-5), with handle eviction
and Degraded health; pinned by a driver-level test (no 0xAA write on the wire, with a positive
control). ST string byte order stated as unverified. Also corrects the docs' "T4:0/DN" examples:
the driver's address grammar is "T4:0.DN" ("/DN" is a malformed address).
- I3: DriverProbeHandshakeE2eTests' two AbCip probe tests are a [Theory] over Native and
Libplctag. Run against ab_server controllogix: all 4 rows pass with identical exact messages.
- M1: documented (docs + resolver XML doc): the AdminUI merges only the probed device, so a
mixed-family defaulted AbLegacy driver can probe Native while running Libplctag.
- M2: factory ParseEnum rejects undefined integer strings ("7") via Enum.IsDefined (both drivers).
- M3: AbCip driver-level bad value reads "AB CIP config in '<id>' has unknown Transport ..."; the
named constant is gone (tagName: null now means driver-level).
- M4: the explicit-Native limited-family Warning is once per instance, not per (re)init.
- Nit: EffectiveTransport docs note that injected factories bypass it.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
Task 22 (spec section 8 P5), with the controller rulings that exclude PLC-5 and LogixPccc.
- Transport is nullable on both option records; null (key absent) means "use the default" and is
never serialized. Factory DTO parse: absent -> null; a bad value still fails via ParseEnum.
- One resolver per driver (AbCipTransportResolver / AbLegacyTransportResolver), used by the driver
constructor, the Test Connect probe and (through the driver) the CLI.
AbCip: null -> Native. AbLegacy: null -> Native unless any device is Plc5 or LogixPccc, then the
whole driver resolves to Libplctag. Explicit values always win; explicit Native with a
Plc5/LogixPccc device logs one Warning at init.
- Init log shows configured vs effective, e.g. transport=Native (default).
- AdminUI forms: "Default (...)" / "Native (managed)" / "libplctag (fallback)". Default omits the
key on save (reverses Task 19's explicit re-emit, which would have pinned every edited driver).
- CLIs: --transport default|native|libplctag, default "default" via the resolver, so
--plc-type Plc5 with no --transport runs libplctag.
- Tests pinned to Libplctag where a default-path runtime was created: found by instrumenting the
native factories with the current xUnit test name (one unit test, AbLegacyReinitConfigAdoption;
plus the two fixture-gated AbCip probe E2E tests whose exact messages were proven on libplctag).
TransportMatrix and the differential harness already pass explicit transports.
- Switch/resolver/CLI/form tests are falsified by mutating the resolver (default -> Libplctag,
exclusion removed, AbLegacy default -> Libplctag): each mutation turns them red.
- Replaces the inline role-name literal in AbCipDriverFactoryExtensions' ParseEnum call with a named
constant; RoleAuthorityGuardTests was already red on the base commit for that line.
- Docs: AbCip.md / AbLegacy.md default + release note; CLAUDE.md AB section.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
M2: after plc_tag_destroy, the release writes 0 back to the wrapper's nativeTagHandle, so a repeat release is a no-op instead of touching a destroyed id. The runtimes keep the destroyed handle for tests and diagnostics.
M1: the rooting fallback is now described accurately, as an unbounded leak (one native tag per failed create), not a bounded one. A test seam (ForceRootingForTest) pins that the fallback roots the tag and destroys nothing.
Both pins are red with their line removed. The orphan tests share a non-parallel collection, because the counters and the seam are process-wide.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
The T21 press pass 1 test host died at exit with "A callback was made on a garbage
collected delegate of type ...plctag+callback_func_ex::Invoke". The cause is in
libplctag.NET 1.5.2. When a tag's create fails, for example with NotFound,
InitializeAsync throws with the callback still registered. Dispose() destroys a tag
only if it is initialised, so the native tag outlives its wrapper. The GC then frees
the delegate, and libplctag's atexit plc_tag_shutdown raises DESTROYED into it.
Reproduced against ab_server: the production LibplctagTagRuntime with a NotFound tag
exits 134 with that exact message, and exits 0 with this fix.
A timed-out create unregisters its callback but never destroys the handle either,
so that native tag keeps reconnecting for the life of the process.
The fix adds LibplctagOrphanRelease (AbCip and AbLegacy). After a failed
initialise/read/write that leaves the tag uninitialised, it reads the handle through
the pinned wrapper's private fields, unregisters the callback and destroys the tag.
If those fields cannot be read, it roots the tag for the life of the process
instead. It is applied in both tag runtimes, the symbol-listing reader and the
template reader. GetStatus keeps the status the tag held before it was destroyed.
Pins: offline refused-connection tests in AbCip.Tests and AbLegacy.Tests, a live
NotFound test on ab_server, and a reflection-shape pin. All go red with the release
disabled. The differential harness also asserts that no orphan had to be rooted.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
- AbCip/AbLegacy driver forms gain a Transport InputSelect; FromOptions/ToOptions now carry
Transport, so saving any other field no longer silently reverts Native to libplctag.
- Both drivers log the constructed transport once per init.
- AbCip factory now takes the host ILoggerFactory (it ran on NullLogger in production, hiding
every AbCip log line); DriverFactoryBootstrap passes it.
- Gate results: AdminUI /run (T19) native, inverted (dead port) and libplctag legs.
The libplctag adapters assigned Tag.Path straight from the device's parsed
CipPath. A device address with no route (ab://host:44818/ - the normal
Micro800 form, and a MicroLogix with no route) parses to "", and libplctag
rejects an empty path attribute with ErrorBadData; omitting the attribute
(null) is what it accepts. So Micro800 could not connect on the default
libplctag transport.
This predates the native transport work and exists on master.
Add an internal LibplctagPath.Normalize helper per driver project (blank ->
null) and route all four Tag constructions through it (AbCip tag runtime,
symbol-list enumerator, template reader; AbLegacy tag runtime). The runtime
tag construction is extracted to an internal BuildTag so tests can inspect
Tag.Path without connecting. Tests fail with Normalize reverted to identity.
Update the Micro800 smoke-test comment: both transports are expected to pass.
ab_server answers every Execute PCCC with a fixed requestor id (pccc.c
PCCC_RESP_PREFIX: 07 3D F3 45 43 50 21) instead of echoing the request's, so
the R14-3 echo check rejected every native reply sent under the 0x1337 CIP
originator identity as BadReply. The pooled runtime now sends libplctag's
identity (PcccServices.RequestorVendor/RequestorSerial), which passes the echo
check against ab_server and against a real controller that echoes. Pinned by a
FakeEipServer round trip that answers with ab_server's fixed prefix.
Found on the docker-dev live gate, not in tests. Two drivers that faulted
during initialise (rtu-gate, opcua1) each rendered "0 tags" on /hosts against
two authored tags apiece, because a ledger that had never committed returned
SkippedTagReport.Empty.
A zero report is a positive claim -- "this driver skipped nothing" -- and
making it on behalf of a driver that never got as far as looking is exactly
the quiet inaccuracy #541 exists to remove. GetSkippedTags() and
SkippedTagLedger.Snapshot() now return null until the first committed build,
so the column renders the same em-dash it already used for a driver that
cannot report at all. Both are 'no answer'; neither is 'nothing skipped'.
Knock-on: a FOCAS driver whose only init threw now reports null rather than a
zero report, which is strictly more honest than the assertion the test
originally made.
A driver builds its RawPath -> definition table at init and tolerates a
per-tag miss: an unmappable TagConfig, an unparseable address, a
capability-matrix rejection. That tolerance is right -- one bad tag must not
take down the other few thousand. What was missing is any statement of the
fact afterwards. A skip is not an error and happens before any read, so the
driver stays Healthy, errors/5 min stays 0, Last error stays empty, and Last
read advances live off the tags that did map. On the wonder Makino in #540
that reading held while focas-z-34184 ignored 20 of its 22 tags.
New optional capability ISkippedTagReporter, backed by a shared
SkippedTagLedger so the reset/commit/cap rules are one implementation rather
than one per driver. The report -- authored count, exact skipped count, and a
capped sample of RawPath + reason -- rides DriverHealthChanged to a new Tags
column on /hosts, over the Phase 5 telemetry stream. No table: a driver-only
node has no ConfigDb to write to, the lesson from #521.
The issue named eight drivers. It is twelve -- every driver in
DriverTypeNames.All has an authored-tag skip path. Calculation (no scriptId),
MTConnect (no readable DataItem id), Galaxy (no attributeRef) and OpcUaClient
(no nodeId) were unlisted, and OpcUaClient's was the quietest of the twelve:
NamespaceMap drops such an entry with a bare `continue` and not even a log
line. SkippedTagReporterFleetTests pins the invariant reflectively over every
IDriver in src/Drivers/, so a thirteenth cannot re-introduce the silence.
Sql drops a tag at TWO points and its report is the union of both: a blob
that does not map, AND an identifier the 8.1 catalog gate rejects against the
live catalog. The second is what schema drift produces -- a renamed column, a
dropped view -- months after a deployment sealed green, and reporting only
the first would have that driver claim "0 skipped" while polling half its
tags, which is worse than reporting nothing because the column would then be
actively reassuring.
Deliberately additive to driver state, never a change of it. Latching
non-Healthy for a config problem would satisfy both halves of the #527
comms-loss conjunction -- 90 s without a successful read AND non-Healthy --
and a driver whose tags were ALL skipped has no successful reads by
construction, so it would reconnect-loop forever against a healthy device.
Three details that are load-bearing rather than incidental:
- The skip digest is part of the publish fingerprint. A skipped tag leaves
every other fingerprint component identical to a clean driver's, so without
it PublishHealthSnapshot's dedup swallows exactly the publish carrying the
signal -- the trap that already bit the rediscovery and host-status
channels. The digest covers the sample, not just the counts: a redeploy
that fixes one tag and breaks another leaves both counts unchanged.
- The count is exact; only the sample is capped, and the tooltip says so when
it is showing fewer than it counted. A truncated list that looked complete
would have an operator fix twenty tags and believe the job done.
- The ledger stages and commits, so an init that throws part-way leaves the
previous report standing. A partial snapshot would read as "we now skip
fewer tags", the opposite of the truth.
The proto field needs no companion presence flag, unlike host_statuses: a
singular message field carries real presence in proto3, and a has_ flag would
collide with protoc's generated HasSkippedTags.
Verified red-first three ways: dropping SkippedTagDigest from the fingerprint
fails the two dedup tests, removing the seam from one driver fails the fleet
guard, and dropping the catalog-gate leg fails the Sql union test. Full
solution builds with zero new warnings against 4e22f024.
Both libplctag drivers carried Port on their tag-create params and consumed it
nowhere. The runtimes set Tag.Gateway to the bare host, and libplctag does not
fail on a portless gateway — it substitutes 44818. So an authored port was not
ignored in the harmless sense; the connection was silently REDIRECTED to whatever
answers on the default port. On a plant network that is another PLC, and the
driver would read its tags and report them Good.
This is the root cause of #534's four AbLegacy integration failures, and the
explanation for every observation in that issue: with each PCCC family moved to
its own port (44819/44820/44821), the driver still dialled 44818 and kept talking
to the AB CIP fixture's ControlLogix container. Hence PCCC-against-ControlLogix
errors under every server-path / client-cip-path permutation — the permutations
were never reaching a PCCC server at all.
Established by a direct libplctag 1.5.2 probe outside the repo, which answered
#534's open question: PCCC works fine against ab_server for all three families,
with path="1,0" AND with path=null (only path="" throws ErrorBadData). Since the
library could reach the simulators and the driver could not, the difference had
to be in our Tag construction, and Gateway was the only field that differed.
Same probe confirmed libplctag accepts host:port in the gateway attribute, which
is what the fix emits.
AbCip has the identical defect and is fixed alongside. It has never been
observable there: every AbCip fixture profile binds 44818, so no test that driver
has could distinguish "uses the authored port" from "always uses 44818". A
fixture that only ever exercises the default value cannot falsify a rule about
non-default values, however many tests point at it.
The port is now emitted unconditionally rather than only when non-default, so the
value does not depend on libplctag's own default; a port <= 0 still falls back to
the bare host rather than producing "host:0".
The load-bearing guard is the AbLegacy integration suite, which addresses each
family on a non-default port and cannot pass unless the port is honoured — 4/4
green, having never once passed before. Unit tests in both drivers pin the
composition for machines with no fixtures. Falsified both ways: reverting the
runtime line reddens all 4 integration tests; dropping the port > 0 guard reddens
exactly the two fallback cases.
AbCip integration 10/13 (3 pre-existing skips), AbCip unit 345, AbLegacy unit 219.
Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
Both `IDriver` members had no production call site. Their only consumer was
`MemoryTracking`, deleted with the driver-tier recycle machinery in #522, and
`GetMemoryFootprint`'s doc-comment claimed "polled every 30s by Core" — which
had not been true since v3, even before #522 removed the poller.
Owner decision on #525 was (a) delete rather than (b) build the process-wide
watchdog that would consume them. The driver-side implementations are in git
history and were mostly reusable; what was always missing is the trigger, and a
member nobody calls is how the misleading doc-comment survived this long.
Removed from `IDriver`, all 12 driver implementations, and every test stub —
plus the support code that existed only to feed them, which is the part a
member-only deletion would have left behind as dead weight:
- MTConnect's three per-entry byte-weight constants, its cached
`ProbeModelDataItemCount`, and `CountDataItems` — a full device-tree walk run
on every cache fill to populate a number with no remaining reader.
- OpcUaClient's `_discoveredNodeCount` field and the discovery-pass write to it.
- MQTT's `ApproxBytesPerAuthoredTag`.
Two behavioural notes, neither a change in what the software does:
- `AbCipTemplateCache` now has no production reset path. Its only caller was
AB CIP's flush, which itself had no caller — so nothing changes except how
visible the fact is. Recorded on the type, along with the correction that its
comment's claim about a device `ReinitializeAsync` also flushing it was never
true. A UDT redefined on a live controller keeps its stale shape until the
driver instance is rebuilt.
- MTConnect's `/probe` cache is still dropped, by `InvalidateProbeModel()` on an
Agent restart. That is now `internal` rather than `private` so the tests which
used the flush purely to empty the cache drive the real path instead — they
now cover a case that actually occurs in production. Several unrelated doc
comments cited `FlushOptionalCachesAsync` as the canonical CAS example and are
repointed to it.
Tests: the ones that existed only to assert on the removed members are deleted
(3 OpcUaClient, 3 Galaxy, 2 MQTT, 1 MTConnect, 1 AbCip). Worth noting one was
vacuous — `FlushOptionalCachesAsync_resets_footprint_counter` asserted a
footprint of 0 before the flush and 0 after with no discovery in between, so it
would have passed against a flush that did nothing at all.
Full suite green except 7 failures verified identical on master before and
after (4 AbLegacy integration with the compose profile down, 3
Host.IntegrationTests), checked by name rather than assumed.
Docs corrected where they described this as live: `DriverLifecycle.md` (which
carried the #525 placeholder), `drivers/AbCip.md`, `drivers/AbLegacy.md`, and
`v2/driver-stability.md` — whose "polls this every 30 s" + per-driver
`DriverConfig` memory budget were never built as written and are now banner-ed
as design intent rather than description.
Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
Five drivers ignored the config handed to them on reinitialize, serving the
options their constructor captured — and the deployment sealed green anyway.
Fixed on both halves, as chosen.
Seam (load-bearing): DriverSpawnPlanner routes a changed DriverConfig to
ToStop + ToSpawn instead of an in-place delta, making the factory the single
parse authority. This REVERSES the deliberate decision documented at
DriverSpawnPlan.cs:49-50 ("a pure DriverConfig change stays an in-place delta
— no reconnect"). That reasoning was correct about the resilience pipeline and
wrong about the driver. The accepted price is a reconnect per config edit.
Per-driver, and this split was not anticipated:
- Re-parse in place — Modbus, AbLegacy, OpcUaClient. ParseOptions extracted
from each factory, called from InitializeAsync behind a HasConfigBody guard
so "{}" still keeps the constructor options.
- Respawn-only, deliberately NOT re-parsed — Sql and FOCAS. Each builds more
than options from config (Sql's dialect + resolved connection string,
FOCAS's client-factory backend, both injected at construction), so adopting
new options alone would run a NEW tag set against an OLD connection. Half a
re-parse is worse than none. SqlDriver's doc-comment asserted the opposite
premise — "config parsing belongs to the factory, which builds a fresh
instance" — which was false when written and is true only now.
Two green seals removed from ApplyChildDelta: it overwrote the cached Spec
synchronously BEFORE the child dequeued the message, so the host believed the
new config was live and the next reconcile computed no delta, sealing the
drift permanently; and it Tell'd with no Receive<ApplyResult> registered, so a
failed reinit — including Galaxy's deliberate NotSupportedException —
dead-lettered.
Exposed (not created) by the change: a factory throw is a CONFIG error, and
SpawnChild catches it and silently substitutes a stub. Only a brand-new driver
could reach that before; an ordinary config edit can now. Raised Warning ->
Error with an actionable message. It still does not fail the deployment —
doing so would let one malformed driver block a fleet deploy, so that is a
follow-up rather than a drive-by.
Tests: every pre-existing reinit test in these suites passes "{}", the exact
input a guarded re-parser treats as "keep constructor options" — blind to this
defect by construction. New tests pass CHANGED json; the Modbus one was
verified falsifiable by deleting the re-parse (goes red). Two tests asserted
the old behaviour and were rewritten, including the positive control in
DriverHostActorUnreadableArtifactTests, whose observable moved from
UnsubscribeAsync to ShutdownAsync now that teardown happens by stopping the
child rather than emptying its desired set.
Remaining full-suite failures are pre-existing and environmental, verified
identical on the pre-change tree: Host.IntegrationTests (3) and
Driver.AbLegacy.IntegrationTests (4, docker fixture-gated).
Every value verified against Opc.Ua.StatusCodes in the pinned SDK (1.5.378.106) by
reflection, not by copying siblings. All are client-visible: OPC UA clients branch on
status.
The three named in #497:
- Historian.Gateway SampleMapper "BadNoData" 0x800E0000 -> 0x809B0000
(0x800E0000 is BadServerHalted)
- Galaxy "BadTimeout" 0x800B0000 -> 0x800A0000
(0x800B0000 is BadServiceUnsupported)
- TwinCAT BadTypeMismatch 0x80730000 -> 0x80740000
(0x80730000 is BadWriteNotSupported)
BadTypeMismatch was wrong in three MORE drivers the issue did not name — FOCAS,
AbLegacy and AbCip carried the same 0x80730000. Every call site is a
FormatException/InvalidCastException conversion failure, so the name was right and
the value was wrong in all four.
Adding the reflection guard then surfaced nine further defects offline tests had
never checked:
- Galaxy GoodLocalOverride 0x00D80000 -> 0x00960000 (not a UA code at all)
- Galaxy UncertainLastUsableValue 0x40A40000 -> 0x40900000
- Galaxy UncertainSensorNotAccurate 0x408D0000 -> 0x40930000
- Galaxy UncertainEngineeringUnitsExceeded 0x408E0000 -> 0x40940000
- Galaxy UncertainSubNormal 0x408F0000 -> 0x40950000
- TwinCAT BadOutOfService 0x80BE0000 -> 0x808D0000 (was BadProtocolVersionUnsupported)
- TwinCAT BadInvalidState 0x80350000 -> 0x80AF0000 (was BadAttributeIdInvalid)
- AbCip/AbLegacy GoodMoreData 0x00A70000 -> 0x00A60000 (was GoodCommunicationEvent)
- Historian.Gateway GatewayQualityMapper Good_LocalOverride 0x00D80000 -> 0x00960000
Galaxy's whole Uncertain block read as though the OPC DA quality byte could be
shifted into the UA substatus position; it cannot — the substatuses are an unrelated
enumeration. GatewayQualityMapper already held the correct table, which is what the
Galaxy values are now reconciled against.
Guard: StatusCodeParityTests (Core.Abstractions.Tests, which already project-
references every driver) reflects over every `const uint` in the deployed
ZB.MOM.WW.OtOpcUa.Driver.*.dll whose name reads as a status code, and asserts it
equals Opc.Ua.StatusCodes.<name>. Discovery is by convention, so a new driver
assembly referenced by that project is covered with no edit here. It went red on all
nine defects above before the fixes and now checks 109 constants green.
Because reflection can only see a NAMED constant, two inline literals were hoisted so
the guard can reach them: Galaxy's BadTimeout/Bad into StatusCodeMap, and
GatewayQualityMapper's 15-entry table into a new HistorianStatusCodes. An inline
`0x800B0000u, // BadTimeout` at a call site is exactly how the Galaxy defect survived.
The drivers stay SDK-free by design; only the test project references Opc.Ua.Core,
as the oracle.
Also corrected: tests that pinned the wrong values (Galaxy StatusCodeMapTests,
SampleMapperTests, GatewayQualityMapperTests — all written from the same bad source),
a mislabelled comment in DriverInstanceActorTests, and stale constants in two design
docs, one of them the unexecuted MTConnect driver design that would have propagated
BadNoData's wrong value into a new driver.
The CLI's SnapshotFormatter value->name table was checked against the SDK and is
correct; no change needed.
Follow-ups from the fleet-wide read-timeout audit that the S7 R2-01 read-leg
fix (PR #453) prompted. The audit confirmed S7 was the ONLY driver with the
async-read-ignores-socket-timeout hang; these are the two adjacent (non-hang)
findings it surfaced.
1. FOCAS TimeoutMs:0 footgun (the risky one): a non-positive Timeout made
SynchronizedFocasClient DISABLE its per-call wall-clock ceiling, reverting to
the caller's long-lived poll token — reintroducing exactly the frozen-peer
wedge S7 just eliminated, under misconfig. Clamp non-positive TimeoutMs to the
2s default at the config boundary so the deadline can never be authored away.
2. TimeoutMs validation symmetry: apply the same clamp in the AbCip + AbLegacy
factories. libplctag's Tag.Timeout setter throws on <=0, faulting tag creation
on every read/write; clamping keeps a misconfigured TimeoutMs:0 running on the
default bound instead. (Shared PositiveTimeoutOrDefault helper per factory.)
3. AbLegacy reconnect parity with AbCip: AbLegacy evicted the cached libplctag
runtime on neither the non-zero-status nor transport-exception read/write path
(AbCip evicts on both), so a data-path fault recovered only via the probe loop
/ libplctag internals. Added EvictRuntime + wired it into both read and write
failure paths so a fresh handle is created on the next call.
Tests: FOCAS 265->269 (clamp theory + positive), AbCip 336->339 (clamp theory +
positive), AbLegacy 209->212 (read-nonzero / read-exception / write-nonzero evict).
No production regressions; all three driver suites green.
Adds <summary>/<param>/<returns>/<inheritdoc> where missing and removes
project bookkeeping IDs (task/tracking refs) from shipped code comments,
so the docs read cleanly and CommentChecker is quiet except for known
false positives (PLC/protocol terms, event/IEqualityComparer inheritdoc).
Doc/comment-only; no logic changed; solution builds clean.
Re-review at 7286d320. -014 (Medium): Bit EncodeValue (no bitIndex) wrote SetInt8 while
DecodeValue read GetInt16 on a 16-bit B-file element, so a false write could round-trip
as true (stale high byte). Fix: SetInt16 + TDD. -015: tests pass CancellationToken.
AdminUI driver-instance pages serialized enum config fields (S7 CpuType,
Modbus DataType/Region, AbCip PlcFamily, ...) as JSON *numbers* because each
page's _jsonOpts lacked a JsonStringEnumConverter. The driver factories,
however, deserialize into string-typed DTOs (+ lenient ParseEnum) and throw
when binding a JSON number to a string? — so an AdminUI-authored config
containing any enum field produced a blob the driver could not parse,
faulting the driver on deploy. Proven end-to-end for S7 and Modbus; latent
for AbCip/AbLegacy/TwinCAT/FOCAS/Galaxy/Historian. Only OpcUaClient was safe
(its factory + probe already carried the converter).
Add JsonStringEnumConverter to all 9 driver-instance pages' _jsonOpts and the
8 missing driver probes' _opts (factories unchanged — already string-via-
ParseEnum; strictly more permissive, also lets pages load hand-seeded
string-enum configs back into the form).
Also fix DriverProbeHandshakeE2eTests.AbCip_Green_AgainstSim to probe a real
sim tag (TestDINT) — the no-tags @raw_cpu_type fallback is rejected by the
ab_server sim with ErrorBadParam (a real ControlLogix returns ErrorNotFound,
which the probe treats as reachable; hardware-gated follow-up).
Tests: reflection guard over all driver pages' _jsonOpts (AdminUI.Tests);
factory round-trip + numeric-form-throws guards for S7 and Modbus.
Found by running the never-before-run FB-9/FB-10 live verifies.
DisposeRuntimes() now disposes and clears _rmwLocks, _creationLocks, and
_runtimeLocks so ReinitializeAsync/ShutdownAsync cycles don't orphan their
SemaphoreSlim instances. Mirrors the TwinCAT _bitRmwLocks fix already shipped.
Replaces the bare-TCP AbLegacyDriverProbe with a two-phase probe:
Phase 1 is the existing TCP preflight; Phase 2 initialises a
LibplctagLegacyTagRuntime (Protocol.ab_eip + per-family PlcType) to
open a real PCCC-over-EIP session, using AbLegacyProbeOptions.ProbeAddress
("S:0") as the probe tag. Status-code discrimination mirrors the AbCip
probe: ErrorNotFound/ErrorNoMatch/ErrorBadDevice → Ok=true "controller
reachable"; transport errors → Ok=false "handshake failed".
Adds AbLegacyDriverProbeTests (5 unit tests, all green, 168 total).
Cheap-and-fast probe: open TCP socket to the configured endpoint,
close immediately. Surfaces SocketError on failure, latency on
success, "timed out" on caller cancel. Sufficient for the AdminUI
Test Connect "can we reach the host?" question. Richer protocol-
level probes (OPC UA session open, FOCAS handshake, gRPC ping)
are a documented follow-up. Each probe registered as
AddSingleton<IDriverProbe, X> in DriverFactoryBootstrap so they
flow through DI into AdminOperationsActor.
Historian.Wonderware returns a clean "TCP probe not applicable"
result because it communicates over a Windows named pipe, not TCP.
Also adds OpcUaClient + Historian.Wonderware.Client project
references to Host.csproj (both were missing from the driver
ItemGroup).