fix(ab): Task 22 review r1 — release-note timing and AbLegacy regressions, probe E2E on both transports
- I1: the upgrade restart itself moves every no-key AbCip/AbLegacy driver to Native (every process start constructs drivers, incl. boot-from-cache). Docs + CLAUDE.md now say so and tell operators to set "transport": "Libplctag" BEFORE upgrading (older builds ignore the unknown key). - I2: AbLegacy release note leads with the status-bit write refusal (T4:0.DN, C5:0.CU, R6:0.EN, ...) on defaulted SLC/MicroLogix drivers and the fallback. The real client status is BadCommunicationError, not BadNotSupported (the driver's write catch-all maps the runtime's AbTransportException like any transport failure, as #571 does for PLC-5), with handle eviction and Degraded health; pinned by a driver-level test (no 0xAA write on the wire, with a positive control). ST string byte order stated as unverified. Also corrects the docs' "T4:0/DN" examples: the driver's address grammar is "T4:0.DN" ("/DN" is a malformed address). - I3: DriverProbeHandshakeE2eTests' two AbCip probe tests are a [Theory] over Native and Libplctag. Run against ab_server controllogix: all 4 rows pass with identical exact messages. - M1: documented (docs + resolver XML doc): the AdminUI merges only the probed device, so a mixed-family defaulted AbLegacy driver can probe Native while running Libplctag. - M2: factory ParseEnum rejects undefined integer strings ("7") via Enum.IsDefined (both drivers). - M3: AbCip driver-level bad value reads "AB CIP config in '<id>' has unknown Transport ..."; the named constant is gone (tagName: null now means driver-level). - M4: the explicit-Native limited-family Warning is once per instance, not per (re)init. - Nit: EffectiveTransport docs note that injected factories bypass it. Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
This commit is contained in:
@@ -977,12 +977,14 @@ Dev/test LDAP is the **shared GLAuth** running on the Linux Docker host at `10.1
|
||||
|
||||
AbCip and AbLegacy have a second, managed wire transport (`Driver.Ab.Transport`) beside libplctag, chosen by
|
||||
the driver-config key `transport` = `Native` | `Libplctag` (string; takes effect when the driver is
|
||||
recreated by a deploy; AdminUI "Transport" dropdown; CLIs `--transport`). **Native is the default (Task 22):**
|
||||
constructed — every process start, so **the upgrade restart alone moves no-key drivers to Native**; set
|
||||
`"transport": "Libplctag"` BEFORE upgrading to stay put; AdminUI "Transport" dropdown; CLIs `--transport`). **Native is the default (Task 22):**
|
||||
an ABSENT key resolves to `Native` via `AbCipTransportResolver` / `AbLegacyTransportResolver` (driver, probe and
|
||||
CLI share them) — except an AbLegacy driver with any PLC-5 / `LogixPccc` device, which resolves to `Libplctag`.
|
||||
"Default" is encoded by omitting the key; the AdminUI must never re-emit a concrete default. Evidence: AbCip
|
||||
reads proven on a real CompactLogix (Z-35162, read-only); AbCip writes and all AbLegacy are `ab_server`-only.
|
||||
Fall back with `"transport": "Libplctag"`. Client-visible: native reports `BadTypeMismatch` where libplctag returned
|
||||
Fall back with `"transport": "Libplctag"`. ⚠️ AbLegacy native refuses status-bit sub-element
|
||||
writes (`T4:0.DN`…, client sees `BadCommunicationError`) and its ST byte order is unverified. Client-visible: native reports `BadTypeMismatch` where libplctag returned
|
||||
Good garbage for a same-width mis-authored type (DINT authored, REAL returned). libplctag is confined to
|
||||
`Libplctag*.cs` adapters by `LibplctagConfinementGuardTests`; do not reference it elsewhere. See
|
||||
`docs/drivers/AbCip.md` §Transport, `docs/drivers/AbLegacy.md`, and
|
||||
|
||||
@@ -97,7 +97,8 @@ The driver has two interchangeable wire transports, selected by one `DriverConfi
|
||||
- An absent key means "use the default". It is resolved in one place, `AbCipTransportResolver`, which the
|
||||
driver, the Test Connect probe and the CLI all go through. An explicit value always wins.
|
||||
- A bad value fails like a bad `PlcFamily`; the Test Connect probe reports "Config JSON is invalid".
|
||||
- A change takes effect when the driver instance is **recreated**. A deploy that changes `DriverConfig`
|
||||
- A change takes effect when the driver instance is **constructed**: on every process start (so the upgrade
|
||||
restart moves no-key drivers to Native — see the release note) and when a deploy that changes `DriverConfig`
|
||||
does this (`DriverHostActor` respawns the child, #516). `ReinitializeAsync` alone keeps the transport
|
||||
it was constructed with.
|
||||
- AdminUI: the **Transport** dropdown in the advanced section of the AbCip driver form ("Default (Native)" /
|
||||
@@ -120,8 +121,11 @@ The driver has two interchangeable wire transports, selected by one `DriverConfi
|
||||
authored type; see [Native transport behaviour](#native-transport-behaviour).
|
||||
- **To fall back**, set `"transport": "Libplctag"` in the driver config (or pick "libplctag (fallback)" in
|
||||
the AdminUI dropdown).
|
||||
- **When it takes effect:** a change of transport — including this default flip for an existing driver with
|
||||
no key — takes effect when a deploy recreates the driver instance, not on `ReinitializeAsync`.
|
||||
- ⚠️ **When it takes effect: the upgrade restart itself.** Every process start constructs the drivers
|
||||
(including boot-from-cache on a driver-only node), so **every driver with no `transport` key moves to Native
|
||||
the moment the upgraded node starts** — no deploy is needed. To keep a driver on libplctag, add
|
||||
`"transport": "Libplctag"` and deploy it **before upgrading**: older builds ignore the unknown key. After the
|
||||
upgrade, a transport change takes effect when a deploy recreates the driver (not on `ReinitializeAsync`).
|
||||
- **Evidence, and its limits:** AbCip **reads** (plus browse and templates) were proven on a production
|
||||
CompactLogix 5069-L320ERS2 (**Z-35162**, read-only, 2026-10-08; see
|
||||
[gate results](../plans/2026-10-07-native-ab-transport-gate-results.md) §Real press). AbCip **writes** are
|
||||
@@ -153,7 +157,7 @@ The driver has two interchangeable wire transports, selected by one `DriverConfi
|
||||
writes are gated on a mismatch too.
|
||||
- Malformed tag names put the device into backoff, as under libplctag (#570). STRING capacity includes the
|
||||
alignment pad (84, not 82) (#570).
|
||||
- Status-bit sub-element writes (e.g. `T4:0/DN`) are Unsupported natively (they would clobber the control
|
||||
- Status-bit sub-element writes (e.g. `T4:0.DN`) are Unsupported natively (they would clobber the control
|
||||
word); nothing goes on the wire. Sub-element arrays are Unsupported natively.
|
||||
|
||||
## Known gaps
|
||||
|
||||
@@ -108,9 +108,17 @@ PCCC-over-EtherNet/IP client (`Driver.Ab.Transport`).
|
||||
the CLI): an absent key resolves to `Native`, **unless any configured device has `PlcFamily` `Plc5` or
|
||||
`LogixPccc`** — then the whole driver resolves to `Libplctag`, because the transport is chosen once per driver,
|
||||
not per device. An explicit value always wins: explicit `Native` with a PLC-5 / `LogixPccc` device is allowed
|
||||
(an operator choice) and logs one Warning at init naming the limitation.
|
||||
(an operator choice) and logs one Warning per driver instance naming the limitation.
|
||||
|
||||
A change takes effect when the driver instance is recreated (a deploy that changes `DriverConfig`). The
|
||||
⚠️ **Test Connect in a mixed-family driver can disagree with the runtime.** The AdminUI probe merges the
|
||||
driver config with **only the device being probed**, so in a defaulted driver holding an SLC 500 and a PLC-5,
|
||||
Test Connect on the SLC device resolves `Native` while the deployed driver runs every device on `Libplctag`.
|
||||
SLC 500 works on both stacks, so this is cosmetic; the reverse (probe on libplctag, driver on native) cannot
|
||||
happen. Set `transport` explicitly to make them agree.
|
||||
|
||||
A change takes effect when the driver instance is constructed: on a deploy that changes `DriverConfig`
|
||||
(which recreates it) **and on every process start**, including the restart that installs this build (see the
|
||||
release note). The
|
||||
AdminUI form's **Transport** dropdown offers "Default (Native; libplctag for PLC-5 / LogixPccc)" (omits the
|
||||
key on save), "Native (managed)" and "libplctag (fallback)". The driver logs
|
||||
`transport=<effective> (default|configured)` on every init, e.g. `transport=Libplctag (default; PLC-5/LogixPccc
|
||||
@@ -124,6 +132,16 @@ Native routing: SLC500/MicroLogix/PLC-5 are direct; `logixpccc` uses Unconnected
|
||||
|
||||
### Release note — native is the default (Task 22)
|
||||
|
||||
- ⚠️ **Status-bit writes are refused on the default.** An SLC 500 / MicroLogix driver on the native default
|
||||
**refuses writes to status-bit sub-elements** — `T4:0.DN`, `T4:0.TT`, `T4:0.EN`, `C5:0.CU`, `C5:0.DN`,
|
||||
`R6:0.EN`, and the rest. The client sees **`BadCommunicationError`** (not `BadNotSupported`: the driver's
|
||||
write path maps the refusal like any transport failure, as for the PLC-5 refusal in #571), the tag's handle
|
||||
is evicted, and driver health goes `Degraded` with "Writes to a status-bit sub-element … are not supported by
|
||||
the native transport". **Nothing is written to the PLC.** libplctag performed a masked bit write here, so an
|
||||
authored writable status-bit tag that worked before the upgrade fails after it. This is deliberate: a native
|
||||
read-modify-write of the control word would race the PLC updating TT/DN and could clobber EN/TT/DN, and such
|
||||
writes are rare. **Drivers that need them must set `"transport": "Libplctag"`.** Reads of status bits are
|
||||
unaffected. Word sub-elements (`T4:0.PRE`, `T4:0.ACC`, `R6:0.LEN`, `R6:0.POS`) still write natively.
|
||||
- **The native managed transport is now the default** for SLC 500 and MicroLogix. A driver config with no
|
||||
`transport` key runs `Native`; libplctag remains available as the fallback.
|
||||
- **Exclusion:** a defaulted driver with **any PLC-5 or `LogixPccc` device stays on libplctag**. Native PLC-5
|
||||
@@ -131,9 +149,14 @@ Native routing: SLC500/MicroLogix/PLC-5 are direct; `logixpccc` uses Unconnected
|
||||
there, with a Warning at init.
|
||||
- ⚠️ **Client-visible:** native reports **`BadTypeMismatch`** for a mis-authored same-width type, where
|
||||
libplctag returned Good garbage (see [AbCip.md §Native transport behaviour](AbCip.md#native-transport-behaviour)).
|
||||
- **ST (string) files:** the native ST file byte order is **unverified** (no capture), so string values read or
|
||||
written natively may be byte-swapped. Drivers with ST tags whose values matter should fall back.
|
||||
- **To fall back**, set `"transport": "Libplctag"` in the driver config.
|
||||
- **When it takes effect:** when a deploy recreates the driver instance (not on `ReinitializeAsync`). An existing
|
||||
driver with no key moves to Native on its next recreate.
|
||||
- ⚠️ **When it takes effect: the upgrade restart itself.** Every process start constructs the drivers
|
||||
(including boot-from-cache on a driver-only node), so **every driver with no `transport` key moves to
|
||||
Native the moment the upgraded node starts** — no deploy is needed. To keep a driver on libplctag, add
|
||||
`"transport": "Libplctag"` and deploy it **before upgrading**: older builds ignore the unknown key. After the
|
||||
upgrade, a transport change takes effect when a deploy recreates the driver (not on `ReinitializeAsync`).
|
||||
- **Evidence, and its limits:** all of AbLegacy is **simulator-proven only** (`ab_server`). No real SLC,
|
||||
MicroLogix or PLC-5 has been exercised. (The real-press gate, Z-35162 2026-10-08, covered AbCip reads only.)
|
||||
|
||||
@@ -144,7 +167,7 @@ Native routing: SLC500/MicroLogix/PLC-5 are direct; `logixpccc` uses Unconnected
|
||||
- **PLC-5 native is N-file reads only.** Every other file type and all PLC-5 writes are refused, currently
|
||||
surfacing as `BadCommunicationError` rather than `BadNotSupported` (#571). The default excludes PLC-5 and
|
||||
`logixpccc` (they resolve to libplctag unless `Native` is set explicitly).
|
||||
- Status-bit sub-element writes (e.g. `T4:0/DN`, `C5:0/DN`) are Unsupported natively (they would clobber the
|
||||
- Status-bit sub-element writes (e.g. `T4:0.DN`, `C5:0.DN`) are Unsupported natively (they would clobber the
|
||||
control word); nothing goes on the wire. Sub-element arrays are Unsupported natively. L-file bit indexes
|
||||
above 15 are allowed.
|
||||
- **ST (string) file layout is uncaptured**, so the string byte order is unverified natively.
|
||||
|
||||
@@ -180,7 +180,8 @@ public sealed class AbCipDriver : IDriver, IReadable, IWritable, ITagDiscovery,
|
||||
/// <summary>The tag factory chosen at construction; exposed so tests can pin transport selection.</summary>
|
||||
internal IAbCipTagFactory TagFactory => _tagFactory;
|
||||
|
||||
/// <summary>The effective transport resolved at construction (see <see cref="AbCipTransportResolver"/>).</summary>
|
||||
/// <summary>The effective transport resolved at construction (see <see cref="AbCipTransportResolver"/>).
|
||||
/// Describes the OPTION only: injected factories (tests) are used regardless.</summary>
|
||||
internal AbCipTransport EffectiveTransport => _transport;
|
||||
|
||||
// The transport chosen at construction (see the ctor); logged at every init so an operator can tell
|
||||
|
||||
@@ -100,7 +100,7 @@ public static class AbCipDriverFactoryExtensions
|
||||
// fails exactly as any other bad enum field does.
|
||||
Transport = string.IsNullOrWhiteSpace(dto.Transport)
|
||||
? null
|
||||
: ParseEnum<AbCipTransport>(dto.Transport, DriverConfigOwner, driverInstanceId, "Transport"),
|
||||
: ParseEnum<AbCipTransport>(dto.Transport, tagName: null, driverInstanceId, "Transport"),
|
||||
EnableControllerBrowse = dto.EnableControllerBrowse ?? false,
|
||||
EnableAlarmProjection = dto.EnableAlarmProjection ?? false,
|
||||
AlarmPollInterval = TimeSpan.FromMilliseconds(dto.AlarmPollIntervalMs ?? 1_000),
|
||||
@@ -123,23 +123,25 @@ public static class AbCipDriverFactoryExtensions
|
||||
private static TimeSpan PositiveTimeoutOrDefault(int? ms, int defaultMs) =>
|
||||
TimeSpan.FromMilliseconds(ms is int v and > 0 ? v : defaultMs);
|
||||
|
||||
// Names the owner of a driver-level enum field in ParseEnum's error text. A named constant rather
|
||||
// than an inline literal: RoleAuthorityGuardTests forbids a bare role-name string literal outside RoleParser.
|
||||
private const string DriverConfigOwner = "(driver config)";
|
||||
|
||||
// tagName null = a driver-level field: the error text names the driver config, not a tag.
|
||||
private static T ParseEnum<T>(string? raw, string? tagName, string driverInstanceId, string field,
|
||||
T? fallback = null) where T : struct, Enum
|
||||
{
|
||||
var subject = tagName is null ? $"config in '{driverInstanceId}'" : $"tag '{tagName}'";
|
||||
if (string.IsNullOrWhiteSpace(raw))
|
||||
{
|
||||
if (fallback.HasValue) return fallback.Value;
|
||||
throw new InvalidOperationException(
|
||||
$"AB CIP tag '{tagName ?? "<unnamed>"}' in '{driverInstanceId}' missing {field}");
|
||||
tagName is null
|
||||
? $"AB CIP {subject} missing {field}"
|
||||
: $"AB CIP {subject} in '{driverInstanceId}' missing {field}");
|
||||
}
|
||||
return Enum.TryParse<T>(raw, ignoreCase: true, out var v)
|
||||
// Enum.TryParse also accepts any integer string ("7"), defined or not; an undefined value would
|
||||
// otherwise fall through to a switch's default arm silently (Task 22 review r1 M2).
|
||||
return Enum.TryParse<T>(raw, ignoreCase: true, out var v) && Enum.IsDefined(v)
|
||||
? v
|
||||
: throw new InvalidOperationException(
|
||||
$"AB CIP tag '{tagName}' has unknown {field} '{raw}'. " +
|
||||
$"AB CIP {subject} has unknown {field} '{raw}'. " +
|
||||
$"Expected one of {string.Join(", ", Enum.GetNames<T>())}");
|
||||
}
|
||||
|
||||
|
||||
@@ -94,7 +94,8 @@ public sealed class AbLegacyDriver : IDriver, IReadable, IWritable, ITagDiscover
|
||||
/// <summary>The tag factory chosen at construction; exposed so tests can pin transport selection.</summary>
|
||||
internal IAbLegacyTagFactory TagFactory => _tagFactory;
|
||||
|
||||
/// <summary>The effective transport resolved at construction (see <see cref="AbLegacyTransportResolver"/>).</summary>
|
||||
/// <summary>The effective transport resolved at construction (see <see cref="AbLegacyTransportResolver"/>).
|
||||
/// Describes the OPTION only: an injected <c>tagFactory</c> (tests) is used regardless.</summary>
|
||||
internal AbLegacyTransport EffectiveTransport => _transport;
|
||||
|
||||
// The transport chosen at construction (see the ctor); logged at every init so an operator can tell
|
||||
@@ -104,6 +105,9 @@ public sealed class AbLegacyDriver : IDriver, IReadable, IWritable, ITagDiscover
|
||||
// Configured-vs-effective rendering of _transport for the init log, e.g. "Native (default)".
|
||||
private readonly string _transportDescription;
|
||||
|
||||
// Set once the explicit-Native-on-a-limited-family Warning has been logged for this instance.
|
||||
private bool _limitedFamilyWarned;
|
||||
|
||||
/// <summary>Upper bound on the poll-loop failure backoff — adopts the S7-proven 30 s cap fleet-wide (05/STAB-8).</summary>
|
||||
private static readonly TimeSpan PollBackoffCap = TimeSpan.FromSeconds(30);
|
||||
|
||||
@@ -153,11 +157,13 @@ public sealed class AbLegacyDriver : IDriver, IReadable, IWritable, ITagDiscover
|
||||
_options = AbLegacyDriverFactoryExtensions.ParseOptions(_driverInstanceId, driverConfigJson);
|
||||
|
||||
// The resolver only defaults a PLC-5 / LogixPccc driver to libplctag; an operator may still pick
|
||||
// Native explicitly (or a reinit may add such a device to a driver resolved Native). Allowed, but
|
||||
// the limitation is client-visible, so name it once per init.
|
||||
if (_transport == AbLegacyTransport.Native
|
||||
// Native explicitly. Allowed, but the limitation is client-visible, so name it ONCE per instance —
|
||||
// not on every init, which includes every comms-loss reconnect retry (Task 22 review r1 M4).
|
||||
if (!_limitedFamilyWarned
|
||||
&& _transport == AbLegacyTransport.Native
|
||||
&& AbLegacyTransportResolver.NativeLimitedFamilies(_options.Devices) is { Count: > 0 } limited)
|
||||
{
|
||||
_limitedFamilyWarned = true;
|
||||
_logger.LogWarning(
|
||||
"AbLegacy driver {DriverInstanceId} runs the Native transport against {Families} device(s); native " +
|
||||
"support is limited there (PLC-5: N-file reads only; LogixPccc: framing unverified). Set " +
|
||||
|
||||
@@ -130,7 +130,8 @@ public static class AbLegacyDriverFactoryExtensions
|
||||
throw new InvalidOperationException(
|
||||
$"AB Legacy {(tagName is null ? "config" : $"tag '{tagName}'")} in '{driverInstanceId}' missing {field}");
|
||||
}
|
||||
return Enum.TryParse<T>(raw, ignoreCase: true, out var v)
|
||||
// Enum.TryParse also accepts any integer string ("7"), defined or not (Task 22 review r1 M2).
|
||||
return Enum.TryParse<T>(raw, ignoreCase: true, out var v) && Enum.IsDefined(v)
|
||||
? v
|
||||
: throw new InvalidOperationException(
|
||||
$"AB Legacy {(tagName is null ? "config" : $"tag '{tagName}'")} has unknown {field} '{raw}'. " +
|
||||
|
||||
@@ -11,6 +11,9 @@ namespace ZB.MOM.WW.OtOpcUa.Driver.AbLegacy;
|
||||
/// is limited (PLC-5: N-file reads only; LogixPccc: framing unverified). The tag factory is chosen once
|
||||
/// per DRIVER, not per device, so one such device resolves the whole driver to
|
||||
/// <see cref="AbLegacyTransport.Libplctag"/>. An explicit value always wins (an operator choice).</para>
|
||||
/// <para>The probe resolves from the config it is GIVEN. The AdminUI merges only the probed device into
|
||||
/// that config, so in a mixed-family defaulted driver Test Connect on an SLC device can resolve Native
|
||||
/// while the deployed driver resolves Libplctag (documented in docs/drivers/AbLegacy.md).</para>
|
||||
/// </summary>
|
||||
public static class AbLegacyTransportResolver
|
||||
{
|
||||
|
||||
@@ -66,6 +66,28 @@ public sealed class AbCipTransportSwitchTests
|
||||
existing.Message.ShouldContain("unknown PlcFamily 'Bogus'");
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// An undefined integer string is rejected, not silently run on a switch's default arm (Task 22 review
|
||||
/// r1 M2): <c>Enum.TryParse</c> alone accepts "7". A defined numeric ("1") still parses, as before.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public void An_undefined_numeric_transport_is_rejected()
|
||||
{
|
||||
Should.Throw<InvalidOperationException>(
|
||||
() => AbCipDriverFactoryExtensions.ParseOptions("ab1", Config("\"7\"")))
|
||||
.Message.ShouldContain("unknown Transport '7'");
|
||||
AbCipDriverFactoryExtensions.ParseOptions("ab1", Config("\"Native\"")).Transport.ShouldBe(AbCipTransport.Native);
|
||||
}
|
||||
|
||||
/// <summary>A bad driver-level value names the driver config, not a "tag" (Task 22 review r1 M3).</summary>
|
||||
[Fact]
|
||||
public void A_bad_transport_names_the_driver_config()
|
||||
{
|
||||
var ex = Should.Throw<InvalidOperationException>(
|
||||
() => AbCipDriverFactoryExtensions.ParseOptions("ab1", Config("\"Bogus\"")));
|
||||
ex.Message.ShouldStartWith("AB CIP config in 'ab1' has unknown Transport 'Bogus'");
|
||||
}
|
||||
|
||||
/// <summary>An explicitly injected factory wins over the option.</summary>
|
||||
[Fact]
|
||||
public void Injected_factory_wins_over_the_option()
|
||||
|
||||
+28
@@ -48,6 +48,34 @@ public sealed class AbLegacyTransportInitLogTests
|
||||
if (warns) warnings[0].Message.ShouldContain(family);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// The Warning is once per INSTANCE, not per init: every comms-loss reconnect retry re-runs init
|
||||
/// (Task 22 review r1 M4). Three inits, one warning.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public async Task The_limited_family_warning_is_logged_once_per_instance_across_reinits()
|
||||
{
|
||||
var config = Config("Native", "Plc5");
|
||||
var captured = new List<(LogLevel, string)>();
|
||||
using var factory = new CapturingLoggerFactory(captured);
|
||||
var driver = AbLegacyDriverFactoryExtensions.CreateInstance("drv-t19", config, factory);
|
||||
try
|
||||
{
|
||||
await driver.InitializeAsync(config, TestContext.Current.CancellationToken);
|
||||
await driver.ReinitializeAsync(config, TestContext.Current.CancellationToken);
|
||||
await driver.ReinitializeAsync(config, TestContext.Current.CancellationToken);
|
||||
}
|
||||
finally
|
||||
{
|
||||
await driver.ShutdownAsync(TestContext.Current.CancellationToken);
|
||||
}
|
||||
|
||||
List<(LogLevel Level, string Message)> snapshot;
|
||||
lock (captured) snapshot = [.. captured];
|
||||
snapshot.Count(m => m.Message.Contains("initializing")).ShouldBe(3); // positive control: three inits ran
|
||||
snapshot.Count(m => m.Level == LogLevel.Warning && m.Message.Contains("native support is limited")).ShouldBe(1);
|
||||
}
|
||||
|
||||
private static async Task<List<(LogLevel Level, string Message)>> InitAndCaptureAsync(string config)
|
||||
{
|
||||
var captured = new List<(LogLevel, string)>();
|
||||
|
||||
@@ -96,6 +96,19 @@ public sealed class AbLegacyTransportSwitchTests
|
||||
existing.Message.ShouldContain("unknown PlcFamily 'Bogus'");
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// An undefined integer string is rejected, not silently run on a switch's default arm (Task 22 review
|
||||
/// r1 M2): <c>Enum.TryParse</c> alone accepts "7". A defined numeric ("1") still parses, as before.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public void An_undefined_numeric_transport_is_rejected()
|
||||
{
|
||||
Should.Throw<InvalidOperationException>(
|
||||
() => AbLegacyDriverFactoryExtensions.ParseOptions("ab1", Config("\"7\"")))
|
||||
.Message.ShouldContain("unknown Transport '7'");
|
||||
AbLegacyDriverFactoryExtensions.ParseOptions("ab1", Config("\"Native\"")).Transport.ShouldBe(AbLegacyTransport.Native);
|
||||
}
|
||||
|
||||
/// <summary>An explicitly injected factory wins over the option.</summary>
|
||||
[Fact]
|
||||
public void Injected_factory_wins_over_the_option()
|
||||
|
||||
+67
@@ -1,6 +1,8 @@
|
||||
using System.Buffers.Binary;
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
||||
using ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.PlcFamilies;
|
||||
using ZB.MOM.WW.OtOpcUa.Driver.Ab.Transport;
|
||||
using ZB.MOM.WW.OtOpcUa.Driver.Ab.Transport.Cip;
|
||||
using ZB.MOM.WW.OtOpcUa.Driver.Ab.Transport.Tests.Captures;
|
||||
@@ -380,6 +382,71 @@ public sealed class NativeAbLegacyTagRuntimeTests
|
||||
h.Channel.SentCount.ShouldBe(0);
|
||||
}
|
||||
|
||||
// These two tests call the driver's WriteAsync directly to pin its OWN status mapping; resilience wrapping
|
||||
// (CapabilityInvoker) is out of scope and would retry/mask the very status under test.
|
||||
#pragma warning disable OTOPCUA0001
|
||||
private sealed class HarnessFactory(Harness h) : IAbLegacyTagFactory
|
||||
{
|
||||
public IAbLegacyTagRuntime Create(AbLegacyTagCreateParams p) =>
|
||||
new NativeAbLegacyTagRuntime(p, h.Scheduler, Vendor, Serial);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Pins the CLIENT-VISIBLE status of the native status-bit write refusal, through the driver (Task 22
|
||||
/// review r1 I2 — the release note states it). The runtime throws AbTransportException(Unsupported);
|
||||
/// the driver's write path does not special-case it, so the client sees the generic transport
|
||||
/// status, and nothing reaches the wire.
|
||||
/// </summary>
|
||||
[Theory]
|
||||
[InlineData("T4:0.DN")]
|
||||
[InlineData("C5:0.CU")]
|
||||
[InlineData("R6:0.EN")]
|
||||
public async Task A_status_bit_write_through_the_driver_reports_the_documented_status(string address)
|
||||
{
|
||||
await using var h = new Harness("slc500", "N7:0").Replies(Words(0));
|
||||
const string host = "ab://10.0.0.1:44818/1,0";
|
||||
var driver = new AbLegacyDriver(new AbLegacyDriverOptions
|
||||
{
|
||||
Devices = [new AbLegacyDeviceOptions(host, AbLegacyPlcFamily.Slc500)],
|
||||
RawTags = AbLegacyRawTags.Entries([new AbLegacyTagDefinition("Bit", host, address, AbLegacyDataType.Bit)]),
|
||||
Probe = new AbLegacyProbeOptions { Enabled = false },
|
||||
}, "drv-sb", new HarnessFactory(h));
|
||||
await driver.InitializeAsync("{}", CancellationToken.None);
|
||||
var results = await driver.WriteAsync([new WriteRequest("Bit", true)], CancellationToken.None);
|
||||
|
||||
// BadCommunicationError, NOT BadNotSupported: the driver's catch-all maps any runtime exception to
|
||||
// it (same as the PLC-5 write refusal, #571), evicts the handle and marks health Degraded.
|
||||
results.Single().StatusCode.ShouldBe(AbLegacyStatusMapper.BadCommunicationError);
|
||||
driver.GetHealth().LastError.ShouldNotBeNull().ShouldContain("status-bit sub-element");
|
||||
// Refused before the wire: the lazy runtime's init read may go out, but never a write (fnc 0xAA).
|
||||
lock (h.Channel.Sent) h.Channel.Sent.ShouldNotContain(r => FncOf(r) == 0xAA);
|
||||
await driver.ShutdownAsync(CancellationToken.None);
|
||||
}
|
||||
|
||||
/// <summary>Positive control for the "no 0xAA on the wire" assertion above: the same driver path for a WORD
|
||||
/// sub-element does send a typed write, so the detector can see one.</summary>
|
||||
[Fact]
|
||||
public async Task A_word_sub_element_write_through_the_driver_sends_a_typed_write()
|
||||
{
|
||||
await using var h = new Harness("slc500", "N7:0").Replies(Words(0));
|
||||
const string host = "ab://10.0.0.1:44818/1,0";
|
||||
var driver = new AbLegacyDriver(new AbLegacyDriverOptions
|
||||
{
|
||||
Devices = [new AbLegacyDeviceOptions(host, AbLegacyPlcFamily.Slc500)],
|
||||
RawTags = AbLegacyRawTags.Entries([new AbLegacyTagDefinition("Pre", host, "T4:0.PRE", AbLegacyDataType.Int)]),
|
||||
Probe = new AbLegacyProbeOptions { Enabled = false },
|
||||
}, "drv-sb", new HarnessFactory(h));
|
||||
await driver.InitializeAsync("{}", CancellationToken.None);
|
||||
|
||||
var results = await driver.WriteAsync([new WriteRequest("Pre", (short)5)], CancellationToken.None);
|
||||
|
||||
results.Single().StatusCode.ShouldBe(AbLegacyStatusMapper.Good);
|
||||
lock (h.Channel.Sent) h.Channel.Sent.ShouldContain(r => FncOf(r) == 0xAA);
|
||||
await driver.ShutdownAsync(CancellationToken.None);
|
||||
}
|
||||
|
||||
#pragma warning restore OTOPCUA0001
|
||||
|
||||
[Theory]
|
||||
[InlineData("T4:0.PRE")]
|
||||
[InlineData("T4:0.ACC")]
|
||||
|
||||
+14
-9
@@ -168,8 +168,10 @@ public sealed class DriverProbeHandshakeE2eTests
|
||||
|
||||
// ---- AbCip : libplctag CIP session handshake (skips unless the sim fixture is up) ----
|
||||
|
||||
[Fact]
|
||||
public async Task AbCip_Green_AgainstSim()
|
||||
[Theory]
|
||||
[InlineData("Native")]
|
||||
[InlineData("Libplctag")]
|
||||
public async Task AbCip_Green_AgainstSim(string transport)
|
||||
{
|
||||
SkipUnless(DockerHost, AbCipPort);
|
||||
// Probe an explicit tag that the ab_server ControlLogix sim actually defines
|
||||
@@ -182,9 +184,9 @@ public sealed class DriverProbeHandshakeE2eTests
|
||||
// exercising the one path the comment above says it does not exercise — and reporting it as a
|
||||
// failure of the fixture rather than of the config shape.
|
||||
var result = await new AbCipDriverProbe().ProbeAsync(
|
||||
// Pinned to libplctag (Task 22 flipped the default to Native): the exact messages below were
|
||||
// proven against ab_server on libplctag; the native path's ab_server coverage is TransportMatrix.
|
||||
$"{{\"Transport\":\"Libplctag\",\"Devices\":[{{\"HostAddress\":\"ab://{DockerHost}:{AbCipPort}/1,0\"}}]," +
|
||||
// Run on BOTH transports (Task 22 review r1 I3): Native is the production default, and the
|
||||
// probe's green messages are transport-neutral strings, so each row asserts the same text.
|
||||
$"{{\"Transport\":\"{transport}\",\"Devices\":[{{\"HostAddress\":\"ab://{DockerHost}:{AbCipPort}/1,0\"}}]," +
|
||||
$"\"RawTags\":[{{\"RawPath\":\"Plant/AbCip/dev1/TestDINT\"," +
|
||||
$"\"TagConfig\":\"{{\\\"tagPath\\\":\\\"TestDINT\\\",\\\"dataType\\\":\\\"DInt\\\"}}\"," +
|
||||
$"\"WriteIdempotent\":false,\"DeviceName\":\"ab://{DockerHost}:{AbCipPort}/1,0\"}}]}}",
|
||||
@@ -214,13 +216,16 @@ public sealed class DriverProbeHandshakeE2eTests
|
||||
/// <c>Docker/patches/0002-ab_server-answer-tag-not-found-with-cip-0x04.patch</c> — so this test
|
||||
/// needs the fixture rebuilt from that patch, not merely running.
|
||||
/// </remarks>
|
||||
[Fact]
|
||||
public async Task AbCip_WithNoAuthoredTags_ReportsTheControllerReachable()
|
||||
[Theory]
|
||||
[InlineData("Native")]
|
||||
[InlineData("Libplctag")]
|
||||
public async Task AbCip_WithNoAuthoredTags_ReportsTheControllerReachable(string transport)
|
||||
{
|
||||
SkipUnless(DockerHost, AbCipPort);
|
||||
var result = await new AbCipDriverProbe().ProbeAsync(
|
||||
// Pinned to libplctag (Task 22): the 0x04 → ErrorNotFound reasoning above is libplctag's.
|
||||
$"{{\"Transport\":\"Libplctag\",\"Devices\":[{{\"HostAddress\":\"ab://{DockerHost}:{AbCipPort}/1,0\"}}],\"RawTags\":[]}}",
|
||||
// Both transports (Task 22 review r1 I3): native maps CIP 0x04 to AbStatus.NotFound exactly as
|
||||
// libplctag's ErrorNotFound does, so the reachable classification is the same.
|
||||
$"{{\"Transport\":\"{transport}\",\"Devices\":[{{\"HostAddress\":\"ab://{DockerHost}:{AbCipPort}/1,0\"}}],\"RawTags\":[]}}",
|
||||
Timeout, Ct);
|
||||
|
||||
result.Ok.ShouldBeTrue($"Probe message: {result.Message}");
|
||||
|
||||