Since #516 a DriverConfig change is stop + respawn, so DriverSpawnPlan.ToApplyDelta
was always empty and the in-place path had no producer. #663 and #664 were both
latent bugs in it. This deletes it:
- host: ApplyChildDelta, _pendingDelta, HandleApplyResult and HandleDeltaApplied
- plan: DriverSpawnPlan.ToApplyDelta
- actor: the ApplyDelta, ApplyResult and DeltaApplied messages, the Connected
reinit handler and the mid-connect AdoptConfigDuringInit
- tests: the actor tests that drove the seam
IDriver.ReinitializeAsync and each driver's implementation and unit tests stay.
Comments and docs that cited AdoptConfigDuringInit as the reason a driver must
release prior state at init now cite the IDriver contract and overlapping
retries, which still apply.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
Nothing read the mapping table beyond the startup validator; v3 UNS projection is
explicit via UnsTagReference. Legacy keys in stored DriverConfig are ignored (pinned).
Reverts the docker-dev opc-plc seed workaround from fdee129f.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
- docs/v2/Galaxy.Performance.md gains a "Value-path batching (2026-08-15)"
section: the batch seams (IBatchSubscribable / PollGroupEngine onBatch ->
AttributeValueBatchPublished -> AttributeValueBatchUpdate -> sink WriteValues
with 512-chunked single-lock batches in the node manager), the invariants (#519
status codes verbatim, per-ITEM metering, Modbus deadband honored via the
driver-filtered buffer, the ValueWriteBatchException partial-failure contract),
the RealmKey re-key, and the pinned dispatcher's throughput 1 -> 100.
- The plan doc gains a "Follow-ups (recorded, not implemented)" section: the
PollGroupEngine unconditional-collection trap (a future per-tag filter in
S7/AbCip/FOCAS would silently reintroduce the deadband-bypass bug), a two-level
driverId -> (rawPath -> refs) routing map, null/empty guard consistency on the
internal batch messages, a possible DriverHostActorLiveValueTests merge, and the
pre-existing aborted-cycle tail-loss on the three unbuffered drivers.
- tasks.json: all 13 tasks completed.
CLAUDE.md needed no edit: its only statement in this area ("One driver publish for
a RawPath fans (in DriverHostActor) to the raw NodeId AND every referencing UNS
NodeId") is still true — batching changed the message granularity, not the
fan-out semantics.
Verification: dotnet build ZB.MOM.WW.OtOpcUa.slnx clean (0 errors, no new warning
classes, zero warnings in any production file). 9 unit projects green, 3470
passed / 5 skipped / 0 failed: Core.Abstractions 305, Core 351+1s, Commons 348,
Runtime 575+3s, OpcUaServer 424+1s, Modbus 399, S7 302, AbCip 410, FOCAS 356.
No DB-backed suite was run — tests/Server/ZB.MOM.WW.OtOpcUa.Server.Tests does not
exist, and nothing this branch touches is covered by the SQL-backed projects.
Reverses the conservative call from the previous commit at the user's direction,
and they were right: "surface it on a counter first" left the wire lying. An
MXAccess event can carry Good quality while its payload is a kind MxValueDecoder
has no mapping for, so the old behaviour published null-under-Good — which a
client cannot tell apart from a genuine null reading. A value the gateway DID
send would be consumed as a value it did not, with the only evidence in a log
nobody is tailing. Bad data is the honest wire representation of lost data.
BadTypeMismatch is an existing StatusCodeMap constant, deliberately reused rather
than written inline: StatusCodeParityTests finds status constants by reflecting
over Good/Uncertain/Bad-prefixed uint fields and checking them against the pinned
SDK, so an inline literal would be invisible to that guard (Gitea #497, where 16
wrong constants had accumulated across 6 drivers exactly this way).
Logging is now once per DISTINCT value kind rather than once per pump. The set is
bounded by the MxValue oneof enum so a broken producer still cannot flood, but a
second unrepresentable kind appearing later gets its own line — warn-once-per-pump
would have silently swallowed it, which is the same class of bug as the null this
commit fixes.
The test's fixture matters more than its assertion: the undecodable event carries
Quality = 192 (OPC DA Good), so a decoder that gave up silently would publish Good
and fail. Paired with a positive control — a decodable value at the same quality
must still publish Good — so it cannot be satisfied by a pump that marks
everything Bad. Falsified by reverting the status to Good: the test reds, and only
that test.
Verified: 331 Galaxy tests green, Core.Abstractions 298 (the parity guard),
solution builds 0 errors. Docs corrected in the two places that recorded the old
decision as deliberate.
Closes the two follow-ups left open by the MxGateway 0.2.0 bump. Reading the
gateway's own contract first changed what each of them is, and one of my earlier
claims was simply wrong -- both corrections are recorded below.
Replay gap
----------
A sentinel MxEvent carries family = UNSPECIFIED, so it fell through EventPump's
family switch into the default drop: we silently ignored a documented MUST ("you
missed events -- discard local state and re-snapshot"). It is now intercepted and
answered by re-issuing SubscribeBulk for every tracked subscription, since
MXAccess delivers an initial value per item on subscribe -- re-subscribing IS the
re-snapshot. It does not restart the event pump (the stream carrying the sentinel
is healthy, and the handler runs on that stream's own read loop, so disposing the
pump from there would deadlock on itself), it does not block the read loop, and
re-entry is gated so a burst collapses to one pass instead of a subscribe storm
per sentinel.
Handled on the READ loop, not in the dispatch loop, because everything past that
point is subject to newest-dropped channel pressure -- and "you missed events" is
the one signal whose loss is unrecoverable. Pinned by a test that fills the
channel and still expects the sentinel.
⚠️ This cannot fire in the shipped configuration, and I did not pretend otherwise
or paper over it by enabling resume. The gateway emits the sentinel only for a
stream opened with after_worker_sequence > 0; GatewayGalaxySubscriber passes 0,
which the gateway treats as "fresh stream, not a resume -- plain attach, no
replay, no sentinel". Enabling resume is a larger and genuinely delicate change:
the sequence is only meaningful within ONE gateway session, our reconnect
recreates the session, and replaying a remembered sequence against a fresh
session sets the server's live watermark ABOVE every event it is about to send --
silencing the stream instead of recovering it. That deserves its own change with
a live gate, which I cannot run from here.
Sparse arrays -- correcting the last commit message
---------------------------------------------------
I wrote that the bump "makes handling it possible" on the decode path. That is
wrong: MxSparseArray is documented write-only, the gateway expands it before
forwarding, and "the worker never receives or produces it". So the decode path
is unreachable by contract and the write path has no use for it either -- it is a
wire compaction for a WHOLE-array write, not a partial update (unmentioned
indices are RESET, deliberately, because the gateway cannot read-modify-write
without racing the provider). It is therefore the wrong primitive for an OPC UA
IndexRange write, which expects untouched elements preserved -- and WriteRequest
carries no IndexRange in the first place.
It is decoded anyway, as contract defence: the alternative if a future gateway
ever emits one is a silent null published under Good quality. Fill semantics
mirror the gateway's own SparseArrayExpander exactly (epoch for Time, empty
string, Integer widening to long[] when any element is int64) so a value that
round-trips through a write reads back as the same CLR array.
Also: the decoder is now total by contract, since it runs inside the dispatch
loop where an escaping exception kills dispatch for the life of the pump. A
malformed payload degrades instead of throwing.
A real defect found in the same code
------------------------------------
A stream the GATEWAY completes -- a closed or evicted session -- ends the RPC
without an error, so nothing threw, the supervisor was never notified, and the
pump exited silently. GetHealth() kept reporting Healthy, which also means the
#527 comms-loss watchdog could never trip, because it requires a non-Healthy
state. The driver went permanently deaf with no signal anywhere. This one is
live, unlike the two above. Now reported as a fault; the falsification control is
the existing CleanShutdown_DoesNotInvokeOnStreamFault, since our own disposal
also ends the stream and must NOT be reported.
Value kinds we cannot represent are now counted and warned once rather than
published as an indistinguishable null. The status is deliberately NOT downgraded
to Bad: nothing can reach that branch today, and changing what an OPC UA client
sees for a live shape is not a change to make without a gate. The counter exists
so the next person has evidence instead of a guess.
Verified: 330 Galaxy tests green (12 new), plus Galaxy.Browser 21, Runtime 558,
Core 351; full solution builds 0 errors with the warning census unchanged. Every
new test was falsified first -- disabling the gap interception reds 3 of 4 (the
throwing-callback test passes vacuously when the callback never runs, by
construction), disabling sparse decode plus the representability signal reds all
7 decoder tests, and both were restored and re-verified green.
Docs: the Galaxy.Performance invariant was stated as received = dispatched +
dropped + in-flight, which this breaks -- a sentinel is received but never enters
the channel -- so it now reads + replay_gaps. Galaxy.md gains the three
operational notes; DriverLifecycle.md records that "reaches a non-Healthy state"
is an obligation a driver can silently fail to meet, which is the general shape
of the clean-end bug.
Review of the ClusterClient-deletion docs sweep (406b1ae5) flagged two
pre-existing staleness items in the swept files, unrelated to ClusterClient
but caught while touching the same passages:
- docs/Telemetry.md: the Phase 5 telemetry section's Status line still said
"code-complete ... live gate has not yet run" — the gate PASSED 2026-07-23
(merge 35552a96), already recorded in CLAUDE.md. Updated to match.
- docs/v2/config-db-schema.md: the AkkaPort/GrpcPort note asserted in the
present tense that "central shares a gossip ring with every node," which
Phase 6 (2026-07-24) ended — central now runs one 2-node Akka mesh per
application Cluster and reaches a site pair only over gRPC. Reworded the
premise to past tense so it no longer contradicts the ClusterClient-deleted
parenthetical sitting right after it.
docs-only; dotnet build ZB.MOM.WW.OtOpcUa.slnx stays green (0 errors).
Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1
Task 3.2 of the ClusterClient->gRPC migration. Sweeps the docs that still
described the Akka ClusterClient transport as live, following its Phase 3
deletion (this branch): MeshTransport:Mode is now Dps (pair-local DPS) or
Grpc (cross-mesh unary calls) only, ClusterClient fails validation loudly,
CentralContactPoints is deleted (not superseded), and the split-topology
validator requires exactly Grpc rather than ClusterClient.
- docs/Configuration.md: rewrite the MeshTransport section — table,
dark-switch/PSK-seeding prose, listener sharing (:4056 driver-role,
:4055 admin-role), remove the "shipped dark, cutover pending" framing.
- docs/Redundancy.md: replace the Dps/ClusterClient transport table with
Dps/Grpc, fix the Phase 6 CentralCommunicationActor + validator bullets.
- docs/Telemetry.md: fix stale ClusterClient cross-refs, add a note that
the driver-role telemetry listener also hosts NodeCommandService.
- docs/v2/config-db-schema.md: one-line "(retired: ...)" annotation on the
historical AkkaPort/GrpcPort note — left as a historical record otherwise.
- CLAUDE.md: rewrite "## Mesh command transport (MeshTransport)" for the
post-deletion world (no ClusterClient/receptionist, per-node gRPC dial,
fire-and-forget semantics unchanged) and fix two Phase 6 bullets.
deferment.md has no mesh-transport mentions; left untouched.
docs-only change; `dotnet build ZB.MOM.WW.OtOpcUa.slnx` stays green (0
errors) after the edit.
Claude-Session: https://claude.ai/code/session_014WNM4vjoVksyyBraTXSZE1
Stage 1b. Still no enforcement wired — this adds the credential model the
identity cutover (stage 2) will read.
ApiKey holds one principal per key, deliberately. The reason to separate keys
from principals is so many keys share a grant set and rotating a key never
touches an ACL row, and that holds with one principal per key since nothing stops
two keys naming the same principal. A key belonging to several principals at once
buys little and costs a join table. UserAuthorizationState.Principals stays a
list, so adding it later needs no ACL-side change.
ApiKeySecret is the security-critical half and is pure, so it is tested on its
own: otua_<keyId>_<secret>, peppered HMAC-SHA256, FixedTimeEquals. Notes why a
plain HMAC rather than an iterated KDF (the secret is 32 bytes of CSPRNG, and the
call runs inline on session activation, which the SDK serializes server-wide
behind its SessionManager event lock), and fails closed on an unset pepper rather
than hashing under an empty key.
Found and fixed a bug in my own first draft: the key id was url-safe base64,
whose alphabet maps '/' to '_' — the very character TryParse splits on. Roughly
one key in five would have had its id truncated at a random position, an
intermittent auth failure reproducing only for SOME keys. The id is hex now, and
the guard is falsified: reverting the alphabet reds both
The_generated_key_id_never_contains_the_separator and, as a bonus signal,
Two_generated_keys_never_collide, because truncated ids collide.
ApiKeyId is NOT NULL, unlike the nullable NodeAclId precedent whose filtered
unique index would admit two NULL ids. Fine for a config row, not for a
credentials lookup key.
OpcUaServer.csproj now references Core. Until now it did not, so
IPermissionEvaluator was literally uncallable from the node manager — the place
enforcement has to happen. No new transitive package surface.
Schema doc updated for both, and its NodeAcl block flagged for pre-existing drift
(it still documents the GenerationId column v3 dropped) without fixing it here.
Core 247, OpcUaServer 364, Configuration 128 — all green.
Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
Both `IDriver` members had no production call site. Their only consumer was
`MemoryTracking`, deleted with the driver-tier recycle machinery in #522, and
`GetMemoryFootprint`'s doc-comment claimed "polled every 30s by Core" — which
had not been true since v3, even before #522 removed the poller.
Owner decision on #525 was (a) delete rather than (b) build the process-wide
watchdog that would consume them. The driver-side implementations are in git
history and were mostly reusable; what was always missing is the trigger, and a
member nobody calls is how the misleading doc-comment survived this long.
Removed from `IDriver`, all 12 driver implementations, and every test stub —
plus the support code that existed only to feed them, which is the part a
member-only deletion would have left behind as dead weight:
- MTConnect's three per-entry byte-weight constants, its cached
`ProbeModelDataItemCount`, and `CountDataItems` — a full device-tree walk run
on every cache fill to populate a number with no remaining reader.
- OpcUaClient's `_discoveredNodeCount` field and the discovery-pass write to it.
- MQTT's `ApproxBytesPerAuthoredTag`.
Two behavioural notes, neither a change in what the software does:
- `AbCipTemplateCache` now has no production reset path. Its only caller was
AB CIP's flush, which itself had no caller — so nothing changes except how
visible the fact is. Recorded on the type, along with the correction that its
comment's claim about a device `ReinitializeAsync` also flushing it was never
true. A UDT redefined on a live controller keeps its stale shape until the
driver instance is rebuilt.
- MTConnect's `/probe` cache is still dropped, by `InvalidateProbeModel()` on an
Agent restart. That is now `internal` rather than `private` so the tests which
used the flush purely to empty the cache drive the real path instead — they
now cover a case that actually occurs in production. Several unrelated doc
comments cited `FlushOptionalCachesAsync` as the canonical CAS example and are
repointed to it.
Tests: the ones that existed only to assert on the removed members are deleted
(3 OpcUaClient, 3 Galaxy, 2 MQTT, 1 MTConnect, 1 AbCip). Worth noting one was
vacuous — `FlushOptionalCachesAsync_resets_footprint_counter` asserted a
footprint of 0 before the flush and 0 after with no discovery in between, so it
would have passed against a flush that did nothing at all.
Full suite green except 7 failures verified identical on master before and
after (4 AbLegacy integration with the compose profile down, 3
Host.IntegrationTests), checked by name rather than assumed.
Docs corrected where they described this as live: `DriverLifecycle.md` (which
carried the #525 placeholder), `drivers/AbCip.md`, `drivers/AbLegacy.md`, and
`v2/driver-stability.md` — whose "polls this every 30 s" + per-driver
`DriverConfig` memory budget were never built as written and are now banner-ed
as design intent rather than description.
Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
The tier system was documented, operator-authorable, and inert. Deleted rather than activated,
because its premise is gone rather than merely unused.
"Tier C" meant a driver running out-of-process behind an IDriverSupervisor that could restart its
Host without tearing down the OPC UA session. No such process exists anywhere: Galaxy reaches
MXAccess over gRPC to the external mxaccessgw sidecar (PR 7.2 retired the in-process
Galaxy.Host/Proxy/Shared projects) and FOCAS has run in-process since its managed wire client
landed 2026-04-24. Consistently, IDriverSupervisor had ZERO implementations and there was nothing
for one to implement against.
The issue understated the inertness. It says the Tier-C-only protections never engaged, implying
the Tier A/B parts did. They did not: nothing constructs MemoryTracking, MemoryRecycle or
ScheduledRecycleScheduler outside their own unit tests, so the whole Core/Stability recycle layer
was dead — meaning option (a), "pass real tiers", was never a flag flip. It would have meant
writing the wiring that never existed AND arming it.
Deleted: MemoryTracking, MemoryRecycle, ScheduledRecycleScheduler, IDriverSupervisor, the
vestigial DriverTypeRegistry (referenced only by its own tests), and the RecycleIntervalSeconds
knob — which the AdminUI let an operator author and the parser validated while it configured
nothing.
DriverTier itself SURVIVES and is load-bearing: DriverResilienceOptions.GetTierDefaults supplies
the real per-capability timeout/retry/breaker policies via DriverFactoryRegistry.GetTier and
DriverCapabilityInvokerFactory. Only the isolation-and-recycle layer above it is gone.
Deliberately NOT deleted:
- WedgeDetector came along in the same directory and is equally dead in production, but it is
tier-agnostic and is not recycle machinery — it only shares the folder. Restored rather than
swept up in a decision that was not about it.
- IDriver.GetMemoryFootprint() and FlushOptionalCachesAsync() lose their only consumer here.
Removing them touches all 12 drivers and every test stub, so they are documented as
consumerless and filed as #525 instead of buried in this diff.
Compatibility: a deployed ResilienceConfig blob still carrying "recycleIntervalSeconds" parses
cleanly (unknown keys are ignored — guarded by a new test, because a blob that suddenly failed to
parse would fall back to tier defaults and silently discard the operator's real overrides), and
the AdminUI's preserve-unknown-keys bag keeps the key rather than rewriting stored config on an
unrelated edit.
The 01/U-6 knob-inertness guard carried an explicit carve-out admitting RecycleIntervalSeconds was
dormant and out of scope; that carve-out is now gone, so the expected set is literally what the
test's name claims.
Note: Host.IntegrationTests has 2 failures (DriverProbeRegistrationTests.is_idempotent,
PrimaryGateFailoverTests) — verified pre-existing by reproducing both on clean master dc9d947b.
Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
tag gate, and fix three silently-broken OpcUaClient integration tests
Continues working through deferment.md's remaining items.
SKIPPED TESTS (13 -> 0 for this reason). The skip said "dark until Batch 4";
Batch 4 shipped as v3.0 and RETIRED the equipment-tag path rather than lighting
it, so every one of them was waiting on something that had already happened and
gone the other way. Resolved individually rather than in bulk:
- REVIVED onto the raw/UNS shape (6): four DriverHostActor primary-gate cases,
the cluster-scoping rebuild, and the real-SDK dual-namespace materialisation
E2E. The behaviour never went dark, only the v2 seeding did.
- FOLDED into a live parity test (3): DeploymentArtifactRawUnsParityTests
already compared RawTagPlan record-equal and RawTagPlan carries array /
historize / alarm intent, so widening its corpus by two tags covers what
three empty placeholder suites had been promising. Those suites are deleted.
- DELETED (4): subjects genuinely retired -- equipment-namespace EquipmentTags,
and both dot-joint {{equip}}.X token suites (that resolver was deleted in
Batch 3; the slash-joint form is covered by DeploymentArtifactEquipRefParityTests).
Falsified, not assumed: removing the seeded UnsTagReference turns two revived
primary-gate tests red; re-homing the SITE-A node to MAIN turns the scoping test
red. Widening a parity corpus also needed direct value assertions -- parity alone
cannot distinguish "both seams right" from "both seams blind".
Runtime.Tests skips 13->3, OpcUaServer.Tests 4->1; all remaining are deliberate
EquipmentDeviceBindingRetired tombstones.
G-7 (deploy-time TagConfig gate). MQTT shipped an Inspect() nobody ever called;
now wired. Replaced the hand-maintained list with a reflection guard, because the
existing test enumerates driver types by hand and so guards renames but can never
notice a gap. NOTE: the first version of that guard was hollow -- it discovered
candidates via GetReferencedAssemblies(), which is circular, since the compiler
elides a reference nothing in the IL uses. Removing MQTT from the map also removed
its Contracts assembly from the manifest, and the guard passed green with the bug
reintroduced. Rewritten to scan the output directory; re-falsified and it now
fails naming MqttTagDefinitionFactory. Residual recorded at the code: Sql,
MTConnect, Calculation and OpcUaClient have no Contracts-side Inspect at all, so
the deploy gate stays weaker than the AdminUI's authoring gate for them.
OPCUACLIENT INTEGRATION TESTS (3 of 4 failing, on master too). Not fixture rot:
the simulator was healthy and Client.CLI read the very same node Good. v3 made the
driver resolve every reference through its authored RawTags table, so a bare
"ns=3;s=StepUp" fails LOCALLY at the resolver with BadNodeIdInvalid and never
reaches the wire -- the tests were exercising the unresolved-reference guard.
Fixed by seeding OpcPlcProfile.RawTags in the deploy artifact's TagConfig shape
and addressing by RawPath. 4/4 pass.
DOCS. Applied the Phase7* -> AddressSpace* rename across the four live docs
(historical bannered files deliberately untouched), resolving the three that are
not renames to their real members. Found en route that the earlier banner pass
missed three files: VirtualTags.md, OpcUaServer.md and ScriptedAlarms.md all
still presented the test-scaffolding GenericDriverNodeManager as the production
dispatch path. All three now carry the correction.
Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
Bookkeeping: 13 .tasks.json files closed — the 8 the audit named, plus
mesh-phase4 (Task 9 landed 3a590a0c), the 4th stillpending phase file, and
historian-tcp-transport closed as OBSOLETE (it targets the retired Wonderware
sidecar; there is no Wonderware backend in the tree). Each carries a
closureNote naming the evidence rather than just a status flip.
11 archreview live gates written back from STATUS.md, which had recorded them
passed since 2026-07-13/15 without ever updating the task files: R2-01 #11,
R2-02 #15/#18, R2-05 T15, R2-06 T12, R2-07 T5/T6/T12/T14, R2-11 T22/T24.
R2-03 and R2-10 were deliberately NOT closed. STATUS.md's headline says "every
Round-2 live gate is now GREEN", but its own per-item detail says R2-03 is
"live-blocked on this data-less rig" and R2-10 verified the pipeline with
"breaker-OPEN state not forced". Both now carry an openNote recording the
actual blocker.
The point of the sweep: ~140 phantom pending tasks are gone, so the genuinely
unexecuted 19-task AdminUI follow-ups plan is now the largest open item in
docs/plans/ instead of being buried under work that shipped months ago.
Tier truth: docs/v2/driver-stability.md now states that its tier table is
aspirational — every driver runs Tier A because no factory passes a tier, so
MemoryRecycle and ScheduledRecycleScheduler have never engaged, and the config
parser validates a RecycleIntervalSeconds that does nothing. It also corrects a
staleness the audit missed: the separate-Windows-service hosting it describes
for Tier C no longer exists (Galaxy moved to the mxaccessgw sidecar in PR 7.2,
FOCAS went in-process with its managed wire client). docs/drivers/README.md
already said Tier A for both, so the two no longer contradict.
No runtime change — enabling recycle on two live drivers wants its own live
gate, not a docs-pass side effect. Keep-or-delete tracked as Gitea #522.
deferment.md §8.1 asked for a decision: wire IPermissionEvaluator into the node
manager, or say plainly that ACLs are not enforced. Decision: the latter. The
evaluator stays in the tree; #520 tracks the wire-up.
Verifying the claim turned up four things worse than the audit recorded:
- docs/security.md, not ReadWriteOperations.md, was the highest-risk doc. It
claimed an anonymous session is "default-denie[d] any node a session has no
ACL grant for". The opposite holds: anonymous can Browse/Read/Subscribe/
HistoryRead the entire address space, and is refused writes and alarm acks
only because it carries no roles.
- Three of five documented data-plane role strings do nothing.
OpcUaDataPlaneRoles declares exactly WriteOperate and AlarmAck; ReadOnly,
WriteTune and WriteConfigure are compared against nowhere in src/. The doc
called all five "exact, case-insensitive, and code-true".
- ReadWriteOperations.md was fiction beyond the ACL claims. OnReadValue has
zero occurrences in src/ — the documented read path did not exist. Reads
never reach a driver: the node manager is push-model and the SDK serves a
Read from the cached pushed value. WriteAuthzPolicy, _sourceByFullRef,
_writeIdempotentByFullRef and IRoleBearer are likewise zero-hit, and
CapabilityInvoker is not referenced by the OpcUaServer project at all. This
file is rewritten rather than bannered.
- v2-release-readiness.md claimed a whole enforcement layer shipped —
FilterBrowseReferences, GateCallMethodRequests, MapCallOperation,
AuthorizationBootstrap, Node:Authorization:* keys. None exist. Whatever
landed on the v2 branch did not survive into the shipped tree.
The UI change is the operative one: ClusterAcls.razor and AclEdit.razor now
warn that a grant is saved and shipped in every deployment artifact but never
evaluated, so an operator cannot author a deny rule believing it works.
deferment.md gains a §9 execution log tracking §8 remediation.
Adds deferment.md — a source-verified inventory of new-driver status, all 17
open issues, in-code deferrals, open live gates and plan bookkeeping. Every
claim was checked against src/ and git, not against documentation.
Headline finding: three subsystems are authored, persisted and shipped but
never executed —
* Node ACLs: IPermissionEvaluator/TriePermissionEvaluator have zero
production consumers and OtOpcUaNodeManager never references them, yet
ClusterAcls.razor authors NodeAcl rows and ConfigComposer.cs:51 ships them
in every artifact. An authored deny rule has no effect.
* IRediscoverable / IHostConnectivityProbe raise into the void (#518/#507);
nothing ever writes a DriverHostStatus row.
* DriverTypeRegistry is vestigial, so no factory passes a tier and every
driver runs Tier A with the Tier-C protections dormant.
Also records the Calculation driver as picker-visible but unauthorable
(DriverConfigModal has no case) — the "registered but unauthorable" class
recurring after the Sql picker defect — and notes that no parity test guards
DriverConfigModal/DeviceModal, which is why it survived review.
Documentation corrections (source-verified):
* ReadWriteOperations.md claimed "a denied read never hits the driver" via
four types that do not exist in src/. Bannered + struck through; a security
review reading that page would have concluded a per-node ACL gate exists.
* CLAUDE.md: the Change Detection sentence was false (DriverHost consumes
nothing); the mesh Phase 4 and Phase 5 live gates and the auto-down 1-vs-1
gate had all PASSED; the ScriptedAlarmState table was already dropped.
* driver-expansion tracking: Modbus RTU and SQL poll are merged, not
pending — its command table would have made someone rebuild two shipped
drivers in a fresh worktree.
* drivers/README.md: dead DriverTypeRegistry paragraph, retired
SystemPlatform namespace kind, missing Sql + Calculation rows, missing
Modbus RTU-over-TCP transport.
* TwinCAT.md/Galaxy.md promised an address-space rebuild that never happens.
* Historian.md gained the #491 unproven-value-capture pointer.
* IncrementalSync.md and AddressSpace.md bannered as wholesale v2-era (the
rewrite is recorded as still owed, not done here); four v2 status docs
bannered as historical; three wrong-name-for-a-live-type fixes.
Left deliberately untouched: the secrets NoOpSecretReplicator line, which
makes a security claim and needs the real behaviour identified rather than a
rename.
Phase 1 gate step 4 failed: setting Enabled = 0 to take a node out of service
returns 422 ClusterEnabledNodeCountMismatch, because
DraftValidator.ValidateClusterTopology requires the enabled-node count to equal
ServerCluster.NodeCount. On a Warm/Hot pair — every cluster on the rig, and
every cluster in the target topology — Enabled can therefore never be the
maintenance hatch. The plan called step 4 "the check that makes step 3
acceptable to ship", so Task 3's behaviour change was not shippable as it stood:
a node down for maintenance would block every deployment to its cluster.
The two rules were each reasonable and contradictory together — the validator
reads Enabled as "part of the declared topology", Phase 1 additionally read it
as "expect an ack". Split the meanings rather than weaken either rule:
Enabled part of the declared topology (validator, untouched)
MaintenanceMode expected to participate now (coordinator + reconciler)
Rejected alternatives: counting configured rather than enabled nodes (drops the
guard against booting a pair into InvalidTopology); downgrading the rule to a
warning (weakens a deploy gate for everyone); shipping with no hatch.
Sabotage: dropping !n.MaintenanceMode from the coordinator query turns the new
test red. It also asserts both nodes remain Enabled, so the fix cannot quietly
regress to disabling the row after all.
Configuration.Tests 95/95, ControlPlane.Tests 101/101, solution builds clean.
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
- docker-dev seed: AkkaPort = 4053 on all six ClusterNode rows, so a freshly
seeded rig matches a migrated one. GrpcPort left null.
- config-db-schema.md: both columns, why AkkaPort is NOT NULL/4053 and GrpcPort
is nullable, the unenforced duplication + its reconciler, and Enabled's new
second meaning as the deploy path's expected-ack set.
- Configuration.md: Cluster:Port / PublicHostname now flag that they are stored
twice, with the "update the row too" instruction and why the drift is silent.
- design doc §7: Phase 1 marked done, plus a "Phase 1 as shipped" note recording
both deviations rather than leaving the sketch reading as what happened.
- program plan: Phase 1 marked done; AdminUI node edit explicitly deferred.
- CLAUDE.md: the deploy-path behaviour change and its three consequences.
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
docs/Redundancy.md's bootstrap section is rewritten around the mechanism that is
actually in force: which of Akka's two bootstrap processes runs is decided by
whether seed-nodes[0] is this node's own address, so the ORDER of Cluster:SeedNodes
is the fix, not a timer. Adds the per-process table, the shipped self-first
example, why the validator is conditional (site nodes are not seeds) and why it
matches PublicHostname rather than the 0.0.0.0 bind address.
The retirement is documented rather than erased: a new subsection explains that a
watchdog outside the join handshake cannot tell "no seed answered" from "a seed
answered and the join is in flight", and the ea45ace1 live-gate finding is kept
verbatim as the evidence that produced that conclusion (InitJoinAck at 10:49:05,
old incarnation retired 10:49:06, watchdog fired 10:49:15, second cluster). The
watchdog's own earlier PASS is kept too — it did pass what it was gated on.
Also: a live gate for the NEW mechanism is registered as outstanding (not
re-drilled on the docker-dev rig since the swap), and the plan doc that shipped
the watchdog gets a superseded banner rather than an edit, so the execution record
and its Task 8 finding stay readable.
Ripple: CLAUDE.md cluster section, docs/Configuration.md + docs/v2/Cluster.md +
docs/ServiceHosting.md SeedNodes entries, the per-cluster-mesh design doc's two
"CLOSED by SelfFormAfter" notes, and mesh-program Phase 6 (which had this
convergence queued — now marked done early) + Phase 7's live-gate name.
First real FOCAS hardware contact (Makino Pro 5 / 31i-B @ 10.201.31.5). A full
v3 data-PDU capture corrected the initial diagnosis: the v3 block envelope is
identical to v1, so only specific payload structs / request math / one client
robustness gap were wrong — not "framing rewrites".
Fixes (all re-validated live through the fixed driver):
- version gate: accept inbound PDU {1,3}, keep emitting v1 (FocasWireProtocol).
- cnc_rdtimer: 8-byte {minute,msec} payload is little-endian (ParseTimer) — the
only decode with an in-range msec field.
- pmc_rdpmcrng: request range widened to the data-type byte width
(end = start + width - 1) so a Word/Long isn't truncated to 0 values
(was spurious BadOutOfRange); decode extracted to ParsePmcRange.
- cnc_rdsvmeter: per-axis LOADELM is 8 bytes (not 12) and names come from the
0x0089 block — ParseServoMeters fixes the misaligned 655360 garbage. Also the
"hang" was NetworkStream.ReadAsync not aborting a stalled socket: ReadExactlyAsync
now disposes the stream on cancellation so a stalled peer can't wedge a poll loop.
- cnc_rddynamic2: contract guard rejecting axis < 1 (driver poll already 1-based).
- FocasDriverProbe: run a real wire session (initiate + cnc_statinfo) instead of
degrading to Ok=true "TCP reachability only" when FWLIB is absent — a bare TCP
listener no longer reports HEALTHY.
cnc_rdparam (0x000e) is unsupported on this control — EW_FUNC across 14
request-framing variants x 4 known-present params; needs a reference FWLIB trace
or is restricted. Deferred (deployed config uses macros, not parameters).
Tests: FOCAS suite 234 green (+16), full solution builds 0 errors. Raw v3
captures checked in under tests/.../Fixtures/v3/. Capture tools under scripts/focas/.
Docs: docs/plans/2026-06-25-focas-pdu-v3-{30i-b-support,implementation-plan}.md,
docs/drivers/FOCAS.md, docs/v2/focas-version-matrix.md,
docs/deployments/wonder-app-vd03-makino-z-34184.md.
Drop the "not yet implemented / BadNotSupported" stale note from all three
S7 CLI --type option descriptions (ReadCommand, WriteCommand, SubscribeCommand)
and replace with accurate help listing the full supported type set, byte-anchored
addressing for wide types, and Timer/Counter read-only status.
docs/v2/driver-specs.md §5: add Supported Data Types table, Byte-Anchored
Addressing table (DBB/MB/IB/QB + examples), Timer/Counter read section with
the Counter-BCD known-limitation, and Deferrals list.
docs/drivers/S7.md: expand Data types to a full table, add "Wide types &
Timer/Counter" section (byte-anchored addressing, Timer/Counter read-only,
Counter BCD known-limitation, deferrals), update Address forms table and
1-D array Deferrals note.
Records T17-T22 as shipped: RoleCarryingUserIdentity, Part 9 method handlers gated on AlarmAck
role, alarm-commands DPS topic, ScriptedAlarmHostActor dispatch, WriteAlarmCondition delta-gate,
AdminUI /alerts Acknowledge/Shelve/Unshelve buttons via AdminOperationsActor singleton, and
Client.CLI ack/confirm/shelve commands. Corrects stale "Not started" / "Partial" entries in
phase-7-status.md (Stream G OPC UA method binding row and C.6 row and Gap 1 body) and adds
the alarm-commands topic to Runtime.md. Removes untracked scratch files resume.md and pending.md.
docker-dev un-stubbed → binds zb-shared-glauth on 10.100.0.35:3893 (dc=zb,dc=local)
via cn=serviceaccount; sign in multi-role/password (group→role seeded by
seed-clusters.sql). Per-VM C:\publish\glauth + base DNs dc=lmxopcua/dc=otopcua
obsolete. Source of truth: scadaproj/infra/glauth/.
Four new docs at docs/v2/ giving a single-page tour of each v2 piece:
- Architecture-v2.md: top-level mental model (fused Host + roles + cluster + live-edit)
- Cluster.md: AkkaClusterOptions + IClusterRoleInfo + WithOtOpcUaClusterBootstrap
- ControlPlane.md: 5 admin singletons + DPS topics + deploy flow + failover recovery
- Runtime.md: per-node actor tree + state machines + engine-wiring follow-up map
Each links back to the design doc for depth. Architecture-v2 cross-references
the other three + ServiceHosting + Redundancy + security.
Five doc-content updates after this session's code-review resolution
sweep. No code touched; pure documentation drift correction.
1. docs/reqs/HighLevelReqs.md (HLR-007 — Service Hosting):
Refreshed the deployment description from "three cooperating
processes (Server, Admin, Galaxy.Host)" to "two cooperating
Windows services (Server, Admin)". The legacy x86 TopShelf
Galaxy.Host process was retired in PR 7.2 (2026-04-30); Galaxy
access now flows through the in-process Tier-A GalaxyDriver
talking gRPC to the sibling mxaccessgw gateway. Also called out
decision #30 (AddWindowsService replacing TopShelf) inline.
2. docs/VirtualTags.md:
- Line 9: "compiled via Microsoft.CodeAnalysis.CSharp.Scripting"
replaced with the current pipeline (Microsoft.CodeAnalysis.CSharp
regular compiler — Core.Scripting-008 / -016 retired the
CSharpScript/ScriptRunner path).
- Line 39: orphan-thread leak description rewritten. The
CSharp.Scripting-era "underlying ScriptRunner keeps running on
its thread-pool thread until the Roslyn runtime returns" is no
longer accurate — the new pipeline binds the script as a
regular C# Func<> delegate, so the leak is now "synchronous
CPU-bound work on a pool thread" (same operator-visible
effect, different mechanism).
3. docs/v2/plan.md decision #29 ("Galaxy Host is a separate Windows
service"):
Annotated both the decision body and the decision-log table row
with "Reversed PR 7.2, 2026-04-30" + a one-line summary of the
replacement architecture. The original reasoning is preserved as
audit trail per the decision-log convention.
4. docs/v2/implementation/phase-7-scripting-and-alarming.md A.1:
Added an Implementation note describing the
Core.Scripting-008 / -016 supersession of the original
CSharpScript pipeline. The historical record stays; the note
points future readers at docs/VirtualTags.md "Compile cache"
for the current contract.
5. docs/plans/alarms-over-gateway.md "Files" section under client
regeneration:
Updated the .NET regeneration instructions to point at the new
ZB.MOM.WW.MxGateway.Contracts.csproj path. The old
clients/dotnet/MxGateway.Client.csproj no longer exists in the
sibling repo (restructure after this plan was written) and the
vendored-binaries situation in
src/Drivers/ZB.MOM.WW.OtOpcUa.Driver.Galaxy/libs/ is called out
so a reader following the plan won't chase a deleted path.
Verification: grep against docs/ for the pre-fix wordings ("three
cooperating processes", "Galaxy.Host (TopShelf)", "ScriptRunner",
the wrong BadDeviceFailure hex code 0x80550000) returns no hits.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Core.Scripting-012 (High, Security) resolution.
The Core.Scripting-008 rewrite broadened the BCL references list from a
narrow allow-list to the full System.* + netstandard +
Microsoft.Win32.Registry set, delegating the security gate entirely to
ForbiddenTypeAnalyzer. Three categories of dangerous BCL types were
reachable from script source without a deny-list entry:
- System.Threading.ThreadPool — QueueUserWorkItem re-introduces the
background-fanout threat Core.Scripting-003 closed against
System.Threading.Tasks.
- System.Threading.Timer — schedules unbounded callback work that
outlives the per-evaluation timeout.
- System.Runtime.Loader.AssemblyLoadContext — loads arbitrary DLLs.
Defense-in-depth gap; invocation needs reflection (already denied)
but the load itself was reachable.
Fix:
- Added 'System.Runtime.Loader' to ForbiddenNamespacePrefixes
(preferred over type-granular per the recommendation so future BCL
additions to that namespace are denied by default).
- Added 'System.Threading.ThreadPool' and 'System.Threading.Timer'
to ForbiddenFullTypeNames — both live in System.Threading shared
with allowed primitives so they must be type-granular.
Regression tests added to ScriptSandboxTests:
Rejects_ThreadPool_QueueUserWorkItem_at_compile
Rejects_Timer_new_at_compile
Rejects_AssemblyLoadContext_at_compile
Docs:
docs/v2/implementation/phase-7-scripting-and-alarming.md decision #6
and the Sandbox-escape compliance-check row both updated to enumerate
the new entries per the Core.Scripting-009 doc-sync convention.
Two lower-impact suggestions from the finding's recommendation
(System.Console, CultureInfo.DefaultThreadCurrentCulture) were
intentionally not addressed and are recorded as accepted minor risks
in the resolution.
Verification: Core.Scripting.Tests 107/107 (was 104 + 3 new rejection
tests).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
The task-galaxy-e2e branch was merged + deleted; the durable reference
is PR #205 alone. Tidies a dangling pointer that future readers might
chase looking for a branch that no longer exists.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Core.ScriptedAlarms-009 resolution: replace the per-call Dictionary +
AlarmPredicateContext allocation with a per-alarm reusable AlarmScratch
held in _scratchByAlarmId, refilled in place under _evalGate on each
evaluation. The hot path no longer allocates per upstream tag change.
Why this matters:
On a busy line where many tags feeding many alarms change frequently,
the old BuildReadCache allocated a fresh dictionary + context on every
predicate evaluation — a steady stream of short-lived allocations the
GC eventually has to reclaim. With the reuse, the dictionary and
context are allocated once per alarm (on first evaluation) and refilled
in place across every subsequent re-eval.
Implementation:
- New private AlarmScratch class holds the reusable
Dictionary<string, DataValueSnapshot> read cache (pre-sized to the
alarm's Inputs.Count) and the AlarmPredicateContext that wraps it by
reference. The context observes refilled values without being
re-created.
- ConcurrentDictionary<string, AlarmScratch> _scratchByAlarmId on the
engine, cleared in LoadAsync alongside _alarms so a config-publish
drops the prior generation's scratch (Inputs / Logger may change).
- EvaluatePredicateToStateAsync looks up scratch via GetOrAdd, calls
the new RefillReadCache(Dictionary, IReadOnlySet) helper to clear +
repopulate the dictionary in place, then runs the predicate against
the reused context.
- BuildReadCache removed.
Safety:
Reuse is serialised under _evalGate which guarantees no two threads
ever observe the same scratch in a half-refilled state. The
AlarmPredicateContext is bound to the scratch dictionary by reference,
so the predicate's ctx.GetTag(path) sees the freshly-refilled values
rather than a stale snapshot.
Verification:
- All 66 ScriptedAlarms tests pass (was 63 — three new regression tests
locking the reuse contract).
- All 56 VirtualTags tests still pass (unchanged).
- All 104 Core.Scripting tests still pass (unchanged).
New tests in ScriptedAlarmEngineTests:
- Reevaluation_reuses_the_same_read_cache_dictionary — asserts
ReferenceEquals(scratch_before, scratch_after) across two
evaluations of the same alarm.
- Reevaluation_reuses_the_same_predicate_context — same, for the
context.
- LoadAsync_drops_the_prior_generations_scratch — asserts a config
publish wipes the prior scratch (so a stale Logger / Inputs can't
leak into the new generation).
Internal test hooks TryGetScratchReadCacheForTest /
TryGetScratchContextForTest added via the existing
InternalsVisibleTo for the tests project. Kept internal — not part of
the public engine surface.
Docs:
- docs/v2/Galaxy.Performance.md "Scripted-alarm engine" section
rewritten as "hot-path allocation reuse" documenting the new
contract + reuse safety reasoning + the three regression tests.
- code-reviews/Core.ScriptedAlarms/findings.md -009 flipped
Won't Fix → Resolved.
- code-reviews/README.md regenerated.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
- Driver.Modbus.Addressing-006: broaden the catch in TryParseFamilyNative
so a future helper throwing a non-Argument/Overflow type still satisfies
the try-parse contract.
- Driver.Modbus.Addressing-007: document that the address grammar does
not carry ModbusStringByteOrder (the structured-tag path does);
add a 'Grammar scope' bullet to docs/v2/dl205.md.
- Driver.Modbus.Addressing-009: reword the ModbusModiconAddress comments
so they don't imply a leading-digit invariant the parser doesn't
enforce.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
- Core.Scripting-005: DependencyExtractor.HandleTagCall now recognises
raw-string literal paths by checking the StringLiteralExpression node
kind instead of the legacy StringLiteralToken kind.
- Core.Scripting-006: scope CompiledScriptCache failed-compile eviction
with TryRemove(KeyValuePair) so a racing retry entry is not evicted.
- Core.Scripting-008: document the per-publish assembly accretion as an
accepted limitation in docs/VirtualTags.md.
- Core.Scripting-009: enumerate the authoritative deny-list (namespace
prefixes + type-granular denies) in the Phase 7 decision-#6 entry to
match ForbiddenTypeAnalyzer.
- Core.Scripting-011: pin ScriptSandbox.Build, ScriptContext.Deadband
boundary semantics, and end-to-end factory + companion-sink
integration.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
- Core.ScriptedAlarms-003: emit OnEvent OUTSIDE _evalGate by collecting
pending emissions during the gate-held section and flushing them after
release; eliminates re-entrancy deadlock the docs already promised.
- Core.ScriptedAlarms-006: track every fire-and-forget Reevaluate /
ShelvingCheck task in _inFlight; Dispose drains the set so the engine
no longer races store writes against teardown.
- Core.ScriptedAlarms-008: store comments as ImmutableList<AlarmComment>
so AppendComment is O(log n) instead of O(n).
- Core.ScriptedAlarms-010: document the deliberate input-quality
asymmetry (Uncertain drives the predicate, renders {?} in the message)
in docs/ScriptedAlarms.md and on MessageTemplate.Resolve remarks.
- Core.ScriptedAlarms-011: propagate the no-op reason through
TransitionResult.NoOp(state, reason) and log it from
ScriptedAlarmEngine.ApplyAsync.
- Core.ScriptedAlarms-009 (Won't Fix per recommendation): documented the
per-evaluation dictionary allocation in docs/v2/Galaxy.Performance.md
with a mitigation path if a future soak surfaces pressure.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
RouteScriptedAlarmMethodCalls now handles ConditionType.AddComment
alongside Acknowledge/Confirm, dispatching to engine.AddCommentAsync.
An empty comment is rejected by the Part 9 state machine and surfaced
as BadInvalidArgument. MapCallOperation gates AddComment at the
AlarmAcknowledge tier — there is no dedicated AddComment permission bit.
Closes phase-7-status.md Gap 1: all Part 9 alarm methods now route to
the engine. Adds 3 unit tests.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
OneShotShelve / TimedShelve / Unshelve now reach the ScriptedAlarmEngine.
Scripted-alarm condition nodes get a ShelvedStateMachine subtree created
before alarm.Create so the stack wires each shelve method's dispatch
handler; AlarmConditionState.OnShelve / OnTimedUnshelve route to the
engine and mirror the result onto the OPC UA node via SetShelvingState.
The three per-instance shelve method NodeIds are indexed so the Call gate
resolves them to OpcUaOperation.AlarmShelve instead of falling through to
generic Call. Engine dispatch is split into the node-free InvokeEngineShelve
so the routing decision is unit-testable.
Adds 9 unit tests; updates phase-7-status.md Gap 1 (only AddComment remains
unwired) and the #24 entry in looseends.md.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Audits every Phase 7 plan stream (A-H) against the repo, confirms the
exit gate is fully closed, and records the five genuine remaining gaps:
OPC UA method-call dispatch for alarm Ack/Confirm/Shelve, the
/virtual-tags and /scripted-alarms Admin UI tabs, the script log viewer,
and the missing production IHistoryWriter for virtual-tag historization.
Also notes that docs/v2/v2-release-readiness.md carries a stale "out of
scope" label — Phase 7 shipped completely after that doc was last updated.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Every item in lmx-followups.md was marked DONE and rooted in the
retired GalaxyProxyDriver / OtOpcUaGalaxyHost named-pipe architecture
deleted in PR 7.2. No live or unique content remains: v2-release-readiness.md
is the canonical open-work tracker. Remove the file and drop the
now-dead link from docs/README.md.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Rewrite src/ and tests/ project paths in docs, CLAUDE.md, README.md, and
test-fixture READMEs to the new module-folder layout (Core/Server/Drivers/
Client/Tooling). References to retired v1 projects (Galaxy.Host/Proxy/Shared,
the legacy monolithic test projects) are left untouched.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Seventeenth PR of the alarms-over-gateway epic
(docs/plans/alarms-over-gateway.md). Lands the script that the
plan calls for in Track D — the actual smoke-run validation
on the dev rig (publish, restart, fire alarms, capture artifacts)
remains operator work; this PR ships the automation that the
operator drives.
scripts/install/Refresh-Services.ps1 — single-shot refresh
script. Designed to run elevated on the deploy host
(DESKTOP-6JL3KKO today; production uses a separate runbook).
The script:
- Stops services in reverse-dependency order (OtOpcUa →
OtOpcUaWonderwareHistorian → MxAccessGw) and force-kills any
residual processes (avoids the publish-time MSB3027 file-lock
the original install script hit).
- Snapshots existing C:\publish trees to
C:\publish\.backup-YYYY-MM-DD-HHMMSS\ for rollback (skip with
-SkipBackup).
- Builds + copies mxaccessgw worker (x86 net48) + server (net10.0)
binaries from the sibling repo.
- Publishes OtOpcUa Server + Wonderware historian sidecar from
this repo.
- Ensures OTOPCUA_HISTORIAN_ALARM_WRITE_ENABLED=true is set on
the historian service env block (PR C.2 toggle).
- Starts services in forward-dependency order with the
inter-service waits the original install used.
- Smoke-verifies (service status, listening ports 5120 / 4840
/ 4841, recent log tails).
Supports -WhatIf for dry-run inspection without touching the
running services.
docs/v2/dev-environment.md — new "Service Refresh —
Refresh-Services.ps1" section between Credential Management
and Test Data Seed. Cross-references the plan's Track D
functional verification scenarios.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>