Phase 2 PR 12 � richer historian quality mapping #11

Merged
dohertj2 merged 1 commits from phase-2-pr12-quality-mapper into v2 2026-04-18 07:22:45 -04:00
Owner

Replace the category-only inline helper in MxAccessGalaxyBackend with a new public HistorianQualityMapper that preserves specific OPC DA subcodes (BadNotConnected, UncertainSubNormal, etc.) instead of collapsing to the 3 family defaults. No wire-contract change (StatusCode is already uint). 21 new tests, 56/56 Host.Tests Unit pass. Branches off v2.

Replace the category-only inline helper in MxAccessGalaxyBackend with a new public HistorianQualityMapper that preserves specific OPC DA subcodes (BadNotConnected, UncertainSubNormal, etc.) instead of collapsing to the 3 family defaults. No wire-contract change (StatusCode is already uint). 21 new tests, 56/56 Host.Tests Unit pass. Branches off v2.
dohertj2 added 1 commit 2026-04-18 07:12:44 -04:00
Phase 2 PR 12 — richer historian quality mapping. Replace MxAccessGalaxyBackend's inline MapHistorianQualityToOpcUa category-only helper (192+→Good, 64-191→Uncertain, 0-63→Bad) with a new public HistorianQualityMapper.Map utility that preserves specific OPC DA subcodes — BadNotConnected(8)→0x808A0000u instead of generic Bad(0x80000000u), UncertainSubNormal(88)→0x40950000u instead of generic Uncertain, Good_LocalOverride(216)→0x00D80000u instead of generic Good, etc. Mirrors v1 QualityMapper.MapToOpcUaStatusCode byte-for-byte without pulling in OPC UA types — the function returns uint32 literals that are the canonical OPC UA StatusCode wire encoding, surfaced directly as DataValueSnapshot.StatusCode on the Proxy side with no additional translation. Unknown subcodes fall back to the family category (255→Good, 150→Uncertain, 50→Bad) so a future SDK change that adds a quality code we don't map yet still gets a sensible bucket. GalaxyDataValue wire shape unchanged (StatusCode stays uint) — this is a pure fidelity upgrade on the Host side. Downstream callers (Admin UI status dashboard, OPC UA clients receiving historian samples) can now distinguish e.g. a transport outage (BadNotConnected) from a sensor fault (BadSensorFailure) from a warm-up delay (BadWaitingForInitialData) without a second round-trip or dashboard heuristic. 21 new tests (HistorianQualityMapperTests): theory with 15 rows covering every specific mapping from the v1 QualityMapper table, plus 6 fallback tests verifying unknown-subcode codes in each family (Good/Uncertain/Bad) collapse to the family default. Galaxy.Host.Tests Unit suite 56/0 (21 new + 35 existing). Galaxy.Host builds clean (0/0). Branches off v2. f24f969a85
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
dohertj2 merged commit 4448db8207 into v2 2026-04-18 07:22:45 -04:00
dohertj2 referenced this issue from a commit 2026-04-19 15:59:55 -04:00
AB CIP PR 2 — scaffolding + Core (AbCipDriver skeleton + libplctag binding + host / tag-path / data-type / status-code parsers + per-family profiles + SafeHandle wrapper + test harness). Ships everything needed to stand up the driver project as a compiling assembly with no wire calls yet — PR 3 adds IReadable against ab_server which is the first PR that actually touches the native library. Project reference shape matches Modbus / OpcUaClient / S7 (only Core.Abstractions, no Core / Configuration / Polly) so the driver stays lean and doesn't drag EF Core into every deployment that wants AB support. libplctag 1.5.2 pinned (1.6.x only exists as alpha — stable 1.5 series covers ControlLogix / CompactLogix / Micro800 / SLC500 / PLC-5 / MicroLogix which matches plan decision #11 family coverage). libplctag.NativeImport arrives transitively. AbCipHostAddress parses ab://gateway[:port]/cip-path canonical strings end-to-end: handles hostname or IP gateway, optional explicit port (default 44818 EtherNet-IP reserved), CIP path including bridged routes (1,2,2,10.0.0.10,1,0), empty path for Micro800 / MicroLogix without backplane routing, case-insensitive scheme, default-port stripping in canonical form for round-trip stability. Opaque string survives straight into libplctag's gateway / path attributes so no translation layer at wire time. AbCipTagPath handles the full Logix symbolic tag surface — controller-scope (Motor1_Speed), program-scope (Program:MainProgram.StepIndex), structured member access (Motor1.Speed.Setpoint), multi-dim array subscripts (Matrix[1,2,3]), bit-within-DINT via .N syntax (Flags.3, Motor.Status.12) with valid range 0-31 per Logix 5000 General Instructions Reference. Structural capture so PR 6 UDT work can walk the path against a cached template without reparsing. Rejects malformed shapes (empty scopes, ident starting with digit, spaces, empty/negative/non-numeric subscripts, unbalanced brackets, leading / trailing dots). Round-trips via ToLibplctagName producing the exact string libplctag's name attribute expects. AbCipDataType mirrors ModbusDataType shape — atomic Bool / SInt / Int / DInt / LInt / USInt / UInt / UDInt / ULInt / Real / LReal / String / Dt plus a Structure marker for UDT-typed tags (resolved via CIP Template Object at discovery time in PR 5/6). ToDriverDataType adapter follows the Modbus widening convention for unsigned + 64-bit until DriverDataType picks those up. AbCipStatusMapper covers the CIP general-status values an AB PLC actually returns during normal operation (0x00/0x04/0x05/0x06/0x08/0x0A/0x0B/0x0E/0x10/0x13/0x16) + libplctag PLCTAG_STATUS_* codes (0, >0 pending, negative error families). Mirrors ModbusDriver.MapModbusExceptionToStatus so Admin UI status displays stay uniform across drivers. PlcTagHandle is a SafeHandle around the int32 native tag ID with plc_tag_destroy slot wired as a no-op for PR 2 (P/Invoke DllImport arrives with PR 3 when the wire calls land). Lifetime guaranteed by the SafeHandle finalizer — every leaked handle gets cleaned up even when the owner is GC'd without explicit Dispose. IsInvalid when native ID <= 0 so destroying a negative (error) handle never happens. Critical because driver-specs.md §3 flags libplctag native heap as invisible to GetMemoryFootprint — leaked handles directly feed the Tier-B recycle trigger. AbCipDriverOptions captures the multi-device shape — one driver instance can talk to N PLCs via Devices[] (each with HostAddress + PlcFamily + optional DeviceName); Tags[] references devices by HostAddress as the cross-key; AbCipProbeOptions + driver-wide Timeout. AbCipDriver implements IDriver only — InitializeAsync parses every device's HostAddress and selects its PlcFamilyProfile (fails fast on malformed strings via InvalidOperationException → Faulted health), per-device state cached in a DeviceState record with parsed address + profile + empty TagHandles dict for later PRs. ReinitializeAsync is the Tier-B escape hatch — shuts down every device, disposes every PlcTagHandle via SafeHandle lifetime, reinitializes from options. ShutdownAsync clears the device dict and flips health to Unknown. PlcFamilies/AbCipPlcFamilyProfile gives four baseline profiles — ControlLogix (4002 ConnectionSize, path 1,0, Large Forward Open + request packing + connected messaging, FW20+ baseline), CompactLogix (narrower 504 default for 5069-L3x safety), Micro800 (488 cap, empty path, unconnected-only, no request packing), GuardLogix (shares ControlLogix wire protocol — safety partition is tag-level, surfaced as ViewOnly in PR 12). Tests — 76 new cases across 4 test classes — AbCipHostAddressTests (10 valid shapes, 10 invalid shapes, ToString canonicalization, round-trip stability), AbCipTagPathTests (18 cases including multi-scope / multi-member / multi-subscript / bit-in-DINT / rejected shapes / underscore idents / round-trip), AbCipStatusMapperTests (12 CIP + 8 libplctag codes), AbCipDriverTests (IDriver lifecycle + multi-device init + malformed-address fault + per-family profile lookup + PlcTagHandle invalid/dispose idempotency + AbCipDataType mapping). Full solution builds 0 errors; 254 warnings are pre-existing xUnit1051 CancellationToken hints outside this PR. Solution file updated to include both new projects. Unblocks PR 3 (IReadable against ab_server) which is the first PR to exercise the native library end-to-end.
Sign in to join this conversation.
No Reviewers
No Label
1 Participants
Notifications
Due Date
No due date set.
Dependencies

No dependencies set.

Reference: dohertj2/lmxopcua#11