Bump ZB.MOM.WW.HistorianGateway.Client + Contracts 1.0.0 -> 1.1.0 (historiangw#135,
release 6365f34). GatewayErrorReasons now reads Client 1.1.0's typed
HistorianGatewayException.StatusCode / ErrorReason / ErrorDomain (constants from
HistorianGatewayErrorReasons) instead of parsing grpc-status-details-bin itself; the
direct Grpc.StatusProto pin and reference are dropped (the client brings it). The
published client maps every RpcException to a HistorianGatewayException, so the
trailer fallback is not needed. Behaviour unchanged: FailedPrecondition +
AGGREGATE_NOT_SUPPORTED_FOR_TAG (domain historian_gateway.v1) ->
BadAggregateNotSupported, everything else keeps its handling.
Adds GatewayErrorReasonsTests (typed-property-only exceptions, so they fail against
the old trailer implementation); wire tests and docs/Historian.md updated.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Range, settings (no migration; OpcUa:Redundancy:Mode unset everywhere), read-only
ConfigDb/SMB/OPC UA preflight on both tiers, #905 scoped swap with -NoStart on both
tiers, #906 failover timing gate (stop the sync-server node as Primary), Unset
metadata gate, rollback with the vd03 #903 drift note. Not executed.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
T13b: the isolated otopcua-t13b pair with OpcUa:Redundancy:Mode absent, on origin/master f826af8e
(it contains c569f806) and A/B on c569f806^ (687256d6). Every check passes on both builds:
- levels 250/240;
- Good data on both nodes;
- writes, Acknowledge, AddComment and alarm delivery on the Secondary;
- graceful stop: the survivor reaches 250 259 ms after Leaving (pre-fix 270 ms);
- crash: 250 at +43.6 s (pre-fix +42.8 s), with no demotion at auto-down;
- rejoin at 240 with no failback.
The role-decision changes are gated on IsWarm and do not run under Unset.
Plan L5, the design's section 4.3 and the Warm table in Redundancy.md now say a Leaving/Exiting node
reports ServiceLevel 0, not 90 (ComputeWarm returns 0 for any member that is not Up/Joining; T13 note A).
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Every applicable T13 leg passes on 0c19f26c + c569f806. The leg list covers:
- metadata and ServiceLevel bands;
- standby projection;
- alarm suppression with Standby ConditionRefresh and the promotion refresh;
- the three D4 demotion timings, run live;
- standby write and Part 9 refusal (BadInvalidState);
- graceful and crash failover, with no failback;
- subscription transfer;
- the Mode=Unset regression.
The two crash-path defects the gate found are fixed in c569f806. Evidence, rig files and the
raw-client harness are in docs/plans/evidence/2026-11-13-717-t13/.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
- T3 WarmSingletonHandoverTests: real 2-node cluster, singleton under ClusterSingletonManager on both nodes; the old
incarnation's held-back publish (older revision, higher sequence) reaches a real Warm OpcUaPublishActor after the
handover and never demotes the new Primary. Pin: a removed node cannot rejoin from its old ActorSystem; a new one
rejoins younger (higher up-number).
- T6 DataEncoding: Binary/XML encoded reads of a structured tag projected on the Standby; scalar encoding error kept;
a DefaultXml item is projected, then promoted through its own encoding (TypeId i=888).
- T7 item deleted between queue and publish; ClientHandle reused by i=2267 on a payload recycled through the SDK 2.0.1
pool (precondition asserted); WarmStandbyCloneMatrixTests over DataChange+DiagnosticInfos/EventNotificationList/
StatusChange, clone/cached immutability, encode round-trip, real-pool stale marker.
- T8 ACL-stood-down item receives nothing from demotion or promotion; restored grant reaches it again.
- T10 per-counter MeterListener tests (by instrument instance): warm_transition, warm_role gauge, snapshot_rejected
(publish actor both reasons + DriverHostActor's ordering gate, first actor test of it), projected_notifications,
suppressed_alarm_events. Process-wide state tests run in non-parallel collections.
- Every test mutation-checked (26 mutations killed); no product bug found. Plan status updated.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Root cause: the protected-DACL coverage scan, not the ACL writes. Both -Reapply and
-Verify walked every denied folder (all of E:\ApiInstall on vd03, nested roots again)
with Get-ChildItem -Recurse + Get-Acl per item + a pipeline per item for -Skip, about
3.4 ms an item on PS 5.1, all while the service was stopped. An unchanged deny is read,
not rewritten; the re-applied install-folder deny propagates over ~1,400 files in 0.5 s.
- Find-OtOpcUaDenyCoverageGap: .NET enumeration, -Skip folders pruned, DACL-only
GetAccessControl(Access) (about 0.15 ms an item); reparse points not followed.
- Get-OtOpcUaCoverageWalkRoots: each denied folder walked once (outermost only).
- Install-ScriptWorkerIsolation.ps1 -Scope All|InstallRoot|Outside (with -Reapply,
-Verify, -PlanOnly). InstallRoot = the folder ACEs a swap drops; Outside = the rest,
including the firewall rule (its query costs 3-5 s; its exe path does not change).
The two partition the plan. Prints the scan time.
- Invoke-OtOpcUaInstallSwap.ps1: -Reapply/-Verify -Scope Outside before the stop (a
failure stops before anything moves), -Scope InstallRoot inside the window; preflight
checks the candidate carries the worker exe; prints the stopped window and its parts.
-NoStart, -NoCarry and the pre-#901 refusal unchanged.
windev, vd03-like tree (17,851 items): stopped window 153.1 s -> 6.0 s (PS 5.1),
101.6 s -> 6.2 s (PS 7); the Outside part takes ~23 s with the old build serving.
Dry-run harness 101 -> 123 passed; Windows test 72 passed on PS 5.1 and PS 7.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
- Wire: an event reported while Active but deferred (#838) is delivered after demotion; the promotion refresh
withholds an ACL-denied condition (positive control alongside); ConditionRefresh2 and model-change events on the
Standby; a native Acknowledge is refused and never routed; Warm validates and advertises the EFFECTIVE
ApplicationUri from an ApplicationConfigPath XML load.
- docs/Redundancy.md: Warm section, the Unset/None i=11314 behaviour (orphan readable by NodeId under Unset,
deleted under None), instruments; OpcUaServer.md, Configuration.md, security.md, cluster-topology rule.
- docker-dev/docker-compose.warm.yml for the T13 gate (central pair, Mode=Warm).
- Plan: implementation status and the test gaps left for T13/follow-up.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
The decision record is keyed by (SubscriptionId, SequenceNumber); the ordinary-tag marker rides
MonitoredItemNotification.Message, validated by ClientHandle and DataValue. The SDK's cached copy is
never mutated. None deletes the SDK's orphan i=11314. T13 gains transfer and durable-restore legs.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
The throwaway loopback spike (11/11 over the wire) shows SDK 2.0.1 clones the cached NotificationMessage on every
Publish, queued send and Republish, and pools notification payloads, so design §4.6's object-keyed provenance and
first-delivery ledger never match a delivered object (0 hits; Good leaks after demotion). A ledger keyed by
(SubscriptionId, SequenceNumber) plus a provenance token on the clone-copied MonitoredItemNotification.Message helper
passed the same matrix. Per the plan's T0 exit rule this re-opens D4's mechanism; T1+ wait for the owner's go/no-go.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Standby writes and Part 9 methods refused BadInvalidState under Warm, promote while the Primary is
unreachable (OpcUa:Redundancy:PromoteWhilePrimaryUnreachable, default on), standby status code
BadOutOfService, no ConfigDb migration, bands as drafted. ScadaBridge#138 is the filed prerequisite.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
DEV vd03 6c4d2990 -> c9640f5c (~101 s), QA pair fea7de0a -> c9640f5c (~91 s pair
outage). #901 settings record written once per node, swaps gated on -Verify,
all gates pass (SL 250 / 250-240, failover no failback, LocalDb sync, canary,
no historian writes). #903 edit-and-revert leaves drift: RowVersion is in the
revision hash.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
No migrations in either range; no #834/#898/#899/#897/#896 findings on DEV or QA.
QA isolation record holds 12 deny paths (OTel collector added 2026-11-12), not 11.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
A picker-form native alarm (attributeRef tag.Attr) only learns the provider-qualified reference
Galaxy!<Area>.tag.Attr from the alarm feed. After a host restart the condition can be restored from
LocalDb before the feed's first snapshot reached the new driver, and an ack in that window dialled the
bare tag.Attr, which the gateway's AcknowledgeAlarm refuses.
The feed now exposes InitialSnapshotCompleted (set on snapshot_complete, after every snapshot entry has
been raised). AcknowledgeAsync resolves the reference through ResolveAlarmAckReferenceAsync: when a
picker-form tag has learned nothing yet and the feed is running, it waits for that snapshot (2 s, and the
caller's token) and dials the reference the snapshot names, so the area always comes from the feed and a
re-areaed object acks under its current area. No reference is guessed: if the snapshot does not name the
alarm, or does not arrive in time, the authored reference is dialled as before and refused visibly.
Chosen over the alternatives in the issue: a GR-browse area lookup can be stale against the runtime
area and is not loaded for authored tags, and a gateway-side tag.Attr resolution needs a cross-repo
deploy and would resolve from the same monitor cache the snapshot already carries.
Tests: 5 driver cases + 1 feed case (fail with the call site / sentinel reverted), and a skip-gated live
gate GalaxyPickerAckBeforeSnapshotLiveTests, run against windev's TEST Galaxy (TestMachine_015.TestAlarm003):
an ack issued before the snapshot dials Galaxy!TestArea.TestMachine_015.TestAlarm003 and is confirmed; with
the call site reverted it fails with the gateway's InvalidRequest refusal.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
The #815 warn-only compatibility window is over. A running Galaxy driver
(InitializeAsync, every gateway ReopenAsync, the ack fallback password) and a
running OpcUaClient driver (session open) now refuse an out-of-namespace
credential reference with the same CredentialReferenceException that save,
deploy (CredentialReferenceOutOfScope), Test Connect and browse already raise,
before any store / environment / file read and before any endpoint is dialled.
The one existing scope check (CredentialReferences.Parse/ResolveAsync) is now
the only path; nothing new was added.
Removed:
- LegacyCredentialReferenceTracker (Core.Abstractions), its rate-limited WARN
and the credential-compat:<field> diagnostics entry.
- The per-driver Legacy* resolve methods and every `legacy` parameter
(GalaxySecretRef, GalaxyAckCredentialResolver, OpcUaUserIdentityFactory,
OpcUaUserCertificatePaths, OpcUaClientSecretResolution).
- IDriverDiagnostics on GalaxyDriver / OpcUaClientDriver (it only carried the
tracker's entries).
- The tracker also kept a pre-#836 absolute UserCertificatePath loading on a
running OpcUaClient driver; that is refused now too.
Preflight / banner decision: KEPT, as a hard error. The Running source
(driver-health credential-compat entries) and CredentialReferenceBannerModel
are gone with the tracker, but the ConfigDb scan still tells an operator
something no other surface does: a Deployed finding is now a driver that is
not connecting, a Draft finding is a deploy the gate will refuse - named
before anyone deploys, e.g. after restoring an old ConfigDb backup or
importing a pre-#815 config. It also carries the #835 cross-instance and
#836/#850 path checks. CredentialReferencePreflightService now logs one Error
per finding (was Warning) with no warn-only wording, and the /raw banner is
alert-danger.
DEV and QA ConfigDbs hold no Galaxy/OpcUaClient driver (checked 2026-11-13);
no production install exists.
Tests: GalaxyDriverLegacyCredentialTests replaced by
GalaxyDriverCredentialScopeTests; new OpcUaClientDriverCredentialScopeTests;
tracker tests in OpcUaClientSecretResolutionTests /
OpcUaClientUserCertificatePathTests deleted; AdminUI preflight tests drop the
Running/banner-model cases and assert Error level. Against the old code the
new refusal tests fail (Galaxy 5/6, OpcUaClient 4/5; the two positive controls
pass on both).
docs/security.md: the migration table now says running drivers refuse; the
warn-only section is replaced by "The compatibility window is over".
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
An upgrade that swaps the install folder dropped the explicit ScriptWorker isolation ACEs on script-worker\, the
install folder and a copied-back pki\ (vd03 2026-11-13). Re-applying needed the operator to repeat the arguments.
- Install-ScriptWorkerIsolation.ps1 records its effective settings (InstallRoot, HostServiceAccount, PeCacheDir,
HostServiceName, ConfigureHostService) beside DenyPaths under ...\Services\OtOpcUaScriptWorker\Parameters (new plan
step SettingsRecord) and locks that key to SYSTEM + Administrators (protected DACL; no secrets recorded).
- -Reapply: re-apply from the record, no arguments; prints a summary line (changed/unchanged).
- -Verify: check only, [ok]/[MISSING] per step, exit 1 when anything is missing. -Uninstall also works from the record.
A node isolated by a pre-#901 installer (DenyPaths only) must run the full-argument install once; both modes say so.
- Invoke-OtOpcUaInstallSwap.ps1: preflight -> stop -> move live/candidate -> carry appsettings/pki/logs ->
-Reapply -> -Verify -> start; a failed -Verify leaves the service stopped. Also the rollback (-NoCarry).
- Tests: dry-run harness 101/101 (record + argument rules; record-key SDDL mutation turns 2 red). The Windows test adds
swap -> Verify fails (exactly the 3 lost ACEs) -> Reapply (3 changed) -> Verify ok -> Reapply 12/12 unchanged, PE-cache
and firewall negative controls, the swap script, and the pre-#901 refusal; 52/52 on windev under 5.1 and 7, with a
scratch local host account and with SYSTEM. Evidence: scripts/validation/opcua-windows-service/evidence/2026-11-13-windev-901-reapply-verify.
- Docs: ServiceHosting isolation section; vd03 pack (swap step, rollback, post-deploy gate, one-time full-argument run),
the 2026-11-13 vd03 record, and the QA pack (QA swap preceded the isolation install; ACLs checked intact over SMB on
vq03/vq04 2026-11-13; next-deploy procedure).
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Owner decision 2026-11-13 on #872 item 1. StatusCodeMap.FromMxStatus now maps a
Pending or Warning row to Uncertain (0x40000000) for any detail, ahead of the
detail vocabulary, keeping the once-per-(detail, category) warning. MXAccess sets
success = -1 on Pending (accepted, in progress); neither category is a failure.
Detail 8001 (automation-object ConfigurationError, write rejected for type
conversion, live-captured on windev 2026-11-13) maps to BadTypeMismatch. 8018
stays BadUserAccessDenied via its SecurityError category, now pinned by a test.
Data change: the value is published Uncertain. Write reply: the result is
Uncertain, never Good, so the server (which commits only Good) reports the write
not committed and reverts the node; a later MXAccess commit arrives as a data
change. Host status is unchanged (probe decode treats Uncertain and Bad alike,
quality < 192 -> Unknown); no alarm path calls the map.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Review of e113faf5 found three gaps in the alarm-feed reverse map:
- A tag hand-authored as Galaxy!<Area>.tag.Attr stopped resolving once Galaxy moved the object to
another area: the feed's full reference named the new area and none of the fallbacks looked at the
authored provider form. Provider-form attributeRefs are now also indexed by their area-free
tag.Attr, and the ack dials the reference the feed now uses.
- A reference composed with an empty area (Galaxy!tag.Attr, the gateway's ComposeFullReference when
the area is blank) with the subtag provider's object-only source reference stripped "tag." and
missed. The part after the '!' is now also tried.
- Resolution ran after the subscription gate, so a transition seen with no handle registered taught
nothing for the ack. It now resolves first; fan-out is still gated.
A picker tag and a provider-form tag for the same alarm resolve deterministically and log a warning.
New tests cover re-area for both forms, subtag shapes, H6-style dotted refs, unmatched/malformed
refs, the collision, pre-subscription learning, and the #869 confirmation of a picker-form ack;
reverted-code runs fail them.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
vd03 runs master 6c4d2990 (#899/#898 read-only historian bindings), self-contained
win-x64, ~15 s downtime, ServiceLevel 250, FOCAS 21/22 Good as before, runner InProcess,
worker isolation re-applied after the folder swap. #898 preflight: 0 historized tags.
#700 second run on the deployed endpoint with historianReadOnly bindings: Boolean
(SysPulse) and Int32 (SysTimeSec) Raw/AtTime typed as the node DataType; native
TimeAverage/Total 9.5/29.5/49.5 and 190/590/990 (= in-process reference), WTC1
all-NULL intervals BadNoData. HistorianGateway /metrics: no EnsureTags/WriteLiveValues
or any write. Temp config + key removed, config back to rev fa9a2e28.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
A node declared numeric whose AVEVA tag is discrete (or string) is not refused up front by #897, so its native
TimeAverage / Total still reach AVEVA, which refuses them. A HistorianGateway at or after historiangw#135
(a220ec0) answers that FailedPrecondition with a google.rpc.ErrorInfo (reason AGGREGATE_NOT_SUPPORTED_FOR_TAG,
domain historian_gateway.v1) in grpc-status-details-bin. The Gateway backend's native processed read now maps
exactly that to HistoryAggregateNotSupportedException (BadAggregateNotSupported for the node) without recording
a health failure or treating it as transport. Any other FailedPrecondition and every Internal (an older gateway's
answer for the same case) keep today's handling.
Detection lives in one place, GatewayErrorReasons. The HistorianGateway.Client pin stays 1.0.0 (1.1.0 is not on
the feed): 1.0.0 keeps the gateway's RpcException, trailers included, as the InnerException of the
HistorianGatewayException it throws, so the reason is read with Grpc.StatusProto 2.76.0 (added via central
package management; nuget.org; same version as Grpc.Core.Api; depends on Google.Api.CommonProtos 2.16.0, which
accepts Google.Protobuf 3.34.1). With Client 1.1.0, ReasonOf becomes
`(ex as HistorianGatewayException)?.ErrorReason` and the StatusProto reference can go.
Tests:
- GatewayAggregateNotSupportedWireTests: in-process gRPC gateway sending the real status + ErrorInfo shape
(copied from historiangw HistorianRpcFaults.ToRpcException), read through the PUBLISHED Client 1.0.0 via the
production adapter: TimeAverage / Total -> HistoryAggregateNotSupportedException, 0 health failures; controls
(Internal; FailedPrecondition without ErrorInfo; other reason; other domain; the reason on Internal) are
rethrown, not IOException, and counted; positive control served.
- DiscreteTagTimeWeightedWireTests: over a real SDK session, a Double / Int32 node on the discrete tag ->
BadAggregateNotSupported with 0 failures; the older gateway's Internal answer keeps its status and counts.
- AvevaGatewayAggregateRefusalLiveGateTests: opt-in read-only live gate (OTOPCUA_AVEVA_GATE_900=true).
Mutations (catch removed; status ignored; domain ignored; reason ignored; inner-exception walk removed) each
fail at least one test. Release build 0 warnings; Historian.Gateway.Tests 601/607 (6 skipped), OpcUaServer
IntegrationTests 323/361 (38 skipped).
Live, read-only: private HistorianGateway container from a220ec0 (API-key auth disabled, live writes off,
removed after) against wonder-sql-vd03: Double and Int32 nodes on SysPulse, TimeAverage and Total ->
BadAggregateNotSupported, health failures unchanged (0); SysTimeSec TimeAverage Good (2 rows); SysPulse Average
served. Gateway traffic was ReadAggregate / ReadRaw / GetTagMetadata only.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
#899 — EnsureTags is an upsert, so binding a node to an existing AVEVA tag via
historianTagname re-typed/re-described it on every add and host start.
- TagConfig `historianReadOnly: true` (TagConfigIntent -> RawTagPlan.HistorianReadOnly):
HistoryRead from an existing historian tag that OtOpcUa never provisions and never
records into (AddressSpaceApplier.IsOwnedHistorizedValue gates both the EnsureTags
hook and the recorder feed). Node-inert: surgical, not mirrored on UNS refs, in the
RawTagPlan equality/hash. A non-bool value is the deploy error HistorianReadOnlyInvalid.
AdminUI: CSV column HistorianReadOnly (strict), TagHistorizeConfig reads via the
runtime parse.
- ServerHistorian:ProvisionTags = CreateOrUpdate (default, unchanged) | CreateOnly
(Gateway only: TagExistsAsync first, existing tags left alone, failed lookup not
sent) | Off. Unknown value / CreateOnly on a SQL backend fail host start.
- Default for an explicit historianTagname stays OWNED: overrides pin owned history
across renames, a read-only default would silently stop provisioning + recording.
#898 — the hook parsed Tag.DataType (an OPC UA name) as DriverDataType, so historized
Float/Double/Byte/SByte tags were never provisioned. New shared
HistorianDataTypeNames.TryResolve: Float->Float32, Double->Float64, Byte/SByte->Int16
(lossless, provisioned as Int2); unmapped names logged at Information. Gateway now skips
Int64/UInt64 (HistorianGateway cannot create Int8/UInt8: lossless-cast-or-reject).
UPGRADE: the first host start after this provisions (upserts) every existing historized
Float/Double/Byte/SByte tag. Mark foreign-tag bindings historianReadOnly, or set
ServerHistorian:ProvisionTags=CreateOnly/Off, before upgrading (docs/Historian.md).
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
libplctag 2.6.0 cannot parse RTC/HSC/... names; tag creation failed with
PLCTAG_ERR_BAD_PARAM, which the status translation reported as BadConnection:
evicted handle, degraded health, counted toward marking a healthy device down.
The libplctag runtime now refuses function-file addresses before creating a
native tag (Unsupported -> BadNotSupported, health untouched), matching native.
Docs: function files are unsupported on both transports, not "unverified".
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
Temporary Calculation-driver nodes bound to existing AVEVA tags (Float ZIPSEN.WTC1,
Byte SysTimeSec/SysPulse, Double missing tag) on vd03, read over OPC UA from the Mac,
then removed; the config is back at its original revision fa9a2e28. Zero historian
writes (gateway metrics: Probe/GetTagMetadata/ReadRaw only). Int32/Boolean bindings
were not deployed because they would trigger an EnsureTags upsert of the existing
AVEVA tag (#899); Float/Double/Byte never provision (#898). Includes the read-only
probe used.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
TimeAverage / Total on a Boolean node over the Gateway backend (AVEVA discrete tag, live
SysPulse) went to the gateway since native TimeAverage/Total became default-on (#694). AVEVA
refuses both modes at StartQuery; the gateway reports that only as Internal /
HistorianServerOperationException (the same answer as a historian storage fault), so the
node answered BadHistoryOperationUnsupported and the read counted as a backend failure.
HistoryRead-Processed now checks the node's scalar DataType before calling any backend and
answers BadAggregateNotSupported (Part 11 6.5.4: "If the Aggregate is not valid for the Node
then the StatusCode shall be Bad_AggregateNotSupported"). Nothing is sent, nothing is counted.
- Shared, every backend: HistoryAggregateDataTypes (Core.Abstractions) applies Part 13
5.4.2.3 Table 50: the numeric-only aggregates (Average, TimeAverage(2), Total(2), Min/Max,
ActualTime, Range, Delta, DeltaBounds, Interpolative, stddev/variance) on a String or
DateTime node are refused. Client-visible: the SQL backends used to answer every interval
BadAggregateInvalidInputs.
- Per backend: IHistorianDataSource.SupportsAggregateFor(aggregate, TypeCode?) (default true;
every production backend declares it, guard-tested). Gateway: false for native
TimeAverage/Total on a Boolean node. SqlServer/QuestDb: true, since they serve Boolean as
0/1 (stepped), so Boolean stays served there, as do the Gateway's raw-evaluated aggregates.
The residual case (a node declared numeric whose AVEVA tag is discrete) cannot be told apart
from a historian fault on the wire and still counts; that needs the gateway to surface
AVEVA's native error code as a deterministic status.
Tests: HistoryAggregateDataTypesTests, guard test, node-manager String/DateTime and per-type
refusals, Gateway capability matrix, DiscreteTagTimeWeightedWireTests (production Gateway
backend over an AVEVA-shaped fake: unsent, 0 health failures, positive controls). Each
mutation (no check, no shared rule, no backend hint, Gateway hint true, shared rule always
true, SQL inheriting the default) fails at least one. Live gate re-run read-only against
AVEVA 2023 R2 via a private HistorianGateway fa9cf31 container: SysPulse TimeAverage on the
wire = BadAggregateNotSupported, health failures unchanged; #801 gate 244 cases pass.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
No public source exists for DNC_ERROR_CLASS / DNC_ERROR_GROUP or their numbers
(the table was written from memory). The iTNC 530 Technical Manual's PLC error
table documents the same class and group NAMES without codes; three real
iTNC 530 records corroborate 7/4, 7/3 and 1/3. DNC and LSV2 numberings are
known to differ (ProgramStatus vs R_RI 26), so the numbers stay unproven.
Docs/comments only; no behaviour change.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
#694 item 3 — historiangw#27 is fixed and now live-verified through OtOpcUa:
- ServerHistorian:Gateway:EnableNativeTimeWeighted defaults to true (false is
the kill switch for a gateway older than 9f711c1). TimeAverage / Total are
served and advertised again (12 aggregates).
- The gateway sends the interval as max(1, round(ms)) and AVEVA clips its last
interval at the request end (live). NativeAggregatePlan therefore sends a
multi-interval grid only for whole-ms intervals; a fractional interval is read
one interval per request (at most 1,000, else BadTooManyOperations), and every
one-interval request goes out rounded UP to whole ms so AVEVA answers one
clipped row. Live, a 3.0004 s clipped interval sent at its own width lost its
last 0.4 ms (Total 123 vs 123.0172).
#746 — HistorianGateway Contracts/Client 1.0.0 surface:
- Alarm history: GatewayAlarmHistorianWriter sends SendEvents batches of <=200.
A failed per-event result is re-sent alone via SendEvent (classified as
before); a refused batch (InvalidArgument etc.) goes event by event so a
poison event dead-letters alone; a systemic fault retries the rest without
sending more; Unimplemented (older gateway) falls back to SendEvent for good.
IHistorianGatewayClient.SendEventsAsync defaults to Unimplemented.
- Events reads: a capped page sends cap + 1 as ReadEventsRequest.max_events, so
the gateway completes the stream instead of the client cancelling it. An
ambiguous capped answer (foreign rows filtered out of the server's cut) or a
refused cap is re-read uncapped with the existing EventDrainBudget drain.
Tests: GatewayServerCappedEventsTests, GatewayAlarmWriterBatchTests,
GatewayNativeWholeMillisecondGridTests (gateway-faithful rounding fake), gate
tests flipped to the new default; every new test mutation-checked (each
mutation of the production change fails at least one). Live harness
AvevaGatewayHistorianFollowupsLiveGateTests (read-only) for #694/#700/#746.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
A UnsTagReference to a raw tag that carries an "alarm" object produced a UNS
value Variable that read BadWaitingForInitialData forever (G6 live gate,
TestAlarm002Condition on testmachine-015). BuildUnsReferenceVariables now skips
those references; the equipment gets the alarm only as the raw condition wired
as an event notifier of its folder, which is unchanged (the reference still
feeds RawTagPlan.ReferencingEquipmentPaths).
Why condition-only and not "feed the mirror":
- The raw side has no value node for such a tag: AddressSpaceApplier
materialises an alarm tag as a condition OR a value variable, never both.
There is no raw value for the UNS mirror to mirror.
- DriverHostActor skips alarm tags when it builds the value fan-out and write
routing maps (`continue` before the UNS registration), and the driver leaves
them out of its value subscription ("subscribed to 5 refs" with 6 tags in
G6). Feeding the mirror would mean subscribing a value the design says the
tag does not have.
- Docs already state condition-only: ScriptedAlarms.md ("instead of a value
variable"), AlarmTracking.md ("only the condition, with no sibling value
variable"), the v3 design (native alarm = one condition at the raw tag,
surfaced at equipment via notifiers).
- The composer tests that asserted the mirror were incidental: f4f3e17e
(v3 B4-WP1) put the alarm on the fixture's Speed tag to test raw alarm
attachment, and later tests reused Speed for writable / historian / array
checks of the mirror. No commit or doc chose a value mirror for alarm tags.
- ScadaBridge does not read it: its OtOpcUa alarm path is event subscriptions
on the equipment/raw folders (v3 alarm B/C live gate), and a node that never
had a value cannot be a working binding. G6 itself authored the alarm's
Boolean as a separate value tag (TestAlarm002), which is the supported way to
read it.
Tests: the composer fixture moves the alarm onto its own HighTemp tag
(Speed is now a plain historized value tag), with a new test asserting no UNS
Variable for the alarm reference, with positive controls (the raw tag still
carries the equipment path; the value references still emit). New real-SDK
test Alarm_bearing_reference_surfaces_as_the_condition_only_against_real_SDK:
no Variable at the UNS path, the Speed mirror present, one condition, the
equipment folder wired as its notifier. Both new tests fail with the skip
removed. Docs: Uns.md, ScriptedAlarms.md, G6 evidence note.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Compared every R_RI decoder we use (22-28, 30-34, 51) byte-for-byte with pyLSV2 (MIT,
97a3d691) and ran the captured iTNC 530 replies through pyLSV2 itself: no decode
disagreement, so no published value changes.
- Additive read-only String leaves Status/ExecutionStateName, Status/ProgramStateName and
Tool/AxisName (pyLSV2 ExecState / PgmState / decode_tool_info names; out-of-table code =
"Unknown"). They ride the raw leaf's feature, so no extra wire read; raw Int32 leaves unchanged.
- Refusals: 52/72 -> BadOutOfRange, 58 -> BadTimeout, 56 -> BadInvalidState, 57 (outside the
alarm walk) -> BadNoData. IsStable and the 57-only alarm-walk end are unchanged.
Lsv2RefusalCodes names every code (pyLSV2 LSV2StatusCode) in exception/log/probe text.
- Timers 30-34 documented as uint32be seconds (lifetime counters) per pyLSV2, hardware-unproven;
TimersEnabled stays false. Axis/tool units: none on the wire, none assumed.
- Lsv2ReadOnlyPolicy untouched (pinned by a test); R_RI 20/21 left out.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
- PLC bit areas (MARKER/INPUT/OUTPUT/COUNTER/TIMER) accept 00/01/FF: real iTNC 530s
return FF for the same operands over R_DP, and pyLSV2 decodes them as non-zero = true.
02..FE stay BadDecodingError.
- New PLC:INPUT_DWORD / PLC:OUTPUT_DWORD areas (pyLSV2 MemoryType 13/12): signed
int32le, element index x 4 over the input/output-word byte pools.
- R_PR offsets agree with pyLSV2. Its count units (BYTE x2, WORD/IW as word counts)
conflict with the captured controls, so we keep the captures and pin them in a test.
- Docs: pyLSV2 correspondence table, native-operand mapping (no aliases), and why
raw R_MB is refused (pyLSV2 logs in as the write-capable PLCDEBUG role). That stays
an owner decision; Lsv2ReadOnlyPolicy is unchanged.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
- HeidenhainControlFamily + HeidenhainControlFamilies.Classify (Contracts): one authority, ported from
pyLSV2 (MIT) dat_cls.py VersionInfo.control (strip spaces, case-insensitive prefix, ITNC530 first).
Families: ITnc530, Tnc (640/620/320/128), Tnc7, Lathe (CNC PILOT 640 / MANUALplus 620), MillPlus,
LegacyTnc (426/430, not a pyLSV2 class), Unknown.
- New additive read-only leaf Controller/Family (String, Identity feature, derived from the same R_VR
reply: no extra request). Lsv2Versions.Family is computed, so record equality and the #831
identity-change rediscovery signal are unchanged. Probe message + /hosts diagnostics (<host>.family).
- DATA gate now goes through SupportsDataPath(family) (pyLSV2 client.py read_data_path is iTNC-only):
non-iTNC and Unknown => Capabilities/DataLogin Unsupported, DATA login never sent. Replaces the
"model contains itnc" substring check (same result on the real iTNC530 controls).
- No per-family selector pre-gates: pyLSV2's TNC 640 observations (27/28/51/30-34 unknown telegram,
25/26 need DNC) are already handled by the reply-driven refusal/suppression path; tests pin it.
- Lsv2ReadOnlyPolicy, HeidenhainTagWritable and the no-IWritable rule are untouched.
- Simulator: per-family ControlProfiles (strings from the pyLSV2 README tables / protocol.rst), both
R_VR field counts, 124-byte R_PR; HeidenhainControlFamilyTests (classification, gates, decoding,
wire log inside the read-only set, refused selectors asked once).
- docs/drivers/Heidenhain.md: Control families matrix (iTNC 530 hardware-proven; the rest per pyLSV2,
hardware-unproven) + open questions (C_CC buffer size, encrypted passwords, R_RI 20/21).
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
The run covered browse (raw + UNS), read, subscribe, write and readback, and a native alarm
through Part 9 to an ack confirmed in Galaxy and a clear. The run found #895 (fixed in
c971b171) and #896 (open). DeployWatcher was not exercised: there is no headless Galaxy
redeploy.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
One owner-approved ack of CVDAisle_1.TableAlarms_008.RuntimeAlert at
2026-11-13T04:17:22Z through docker-dev site-b-1 -> vd03 mxaccessgw 76a71bc8.
.Acked True, .AckMsg = comment, gateway feed ACTIVE_ACKED, v_AlarmEventHistory2
ACK_ALM with the NAM operator and OperatorNode MxGateway. The 11-11 failure
was the vd03 gateway build (4f931e4, pre-AckMsg wnwrap AlarmAckByName no-op),
not #226/#228.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Read-only ADS gate from WW_DEV_VM: port 10000 Config, port 851 absent (error 6).
Boot project is the committed OtOpcUaTwinCatFixture without GVL_Perf/FB_PerfChurn.
Member writes, coalescing and #761 array writes remain blocked; no multi-hop hardware.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Re-ran every gate docker-dev and the fixtures can run, on master 412da27c plus the
deploy-API fix: A (now with dotnet-counters), B, C, D check 4 (after #785), E, H1
live end-to-end over OPC UA (N=0 year window: 6 pages <= 10k, continuation points,
all 52,560 values), the gate-F removal drop on the VD03 gateway (4 -> 2 within 15 s),
and all fixture lanes incl. the first G1 MTConnect run. All pass.
Recorded: the AbCip "writes" combination ran no writes (AB_DIFF_ENDPOINT gates them
off), a C-style pause past 15 s leaves a split SITE-B pair, and simulator evidence for
four of the five hardware userGates (TwinCAT has no simulator). The hardware
userGates stay open.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
- #890: installer at f75ee7d0 re-applied on both nodes with -DenyPaths root, pki, data and
C:\ProgramData\ZB\kek (the Secrets KEK sits outside the install root); second apply 12/12 unchanged.
- Script-runner canary authored in the AdminUI and deployed (Calculation tag + VirtualTag, 1 s timers):
Good and advancing on both endpoints; kept on QA as a runner monitor.
- #794 step 5: the live worker token is restricted (SeChangeNotify only; identity/Everyone/Users/RESTRICTED)
and is denied read and write on pki, data, app, logs and the KEKs; network sockets none. Finding #891.
- #780: QA runaway drill passed (killed at the 4000 ms hard deadline twice, quarantined, siblings Good,
ServiceLevel 250/240 unchanged); drill removed, redeploy back to the canary revision 82dd0598.
- #780 P4 recorded: InProcess stays the default and the rollback; StuckOrphanQuarantineFactor documented
as in-process only.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
The installer denied NT SERVICE\OtOpcUaScriptWorker only on -InstallRoot. On the wonder layout the node's keys and
secrets sit beside it (E:\ApiInstall\OtOpcUa\pki with the application certificate's private key, data\ with
secrets.db and LocalDb), inheriting BUILTIN\Users:RX. Users is a restricting SID of the worker token, so a worker
could read them.
- Install-ScriptWorkerIsolation.ps1 -DenyPaths <dir>,...: each folder gets the same inherited deny as InstallRoot
(new SensitiveDirDeny steps). Refuses drive/share roots, script-worker\ and the PE cache; folders must exist;
a comma/semicolon string works for powershell -File.
- The deny is read AND write (0xD0157: ReadData, WriteData, AppendData, WriteEA, DeleteChild, WriteAttributes,
Delete, WRITE_DAC, WRITE_OWNER). Traverse/Execute, ReadAttributes, ReadControl and Synchronize stay so the
loader still reaches script-worker\. The write half stops a worker planting a cert in pki\trusted\certs where
a data drive lets Users create files in subfolders.
- The list is recorded under the anchor service's key (Parameters\DenyPaths, step DenyPathRecord): a re-run
removes the deny from folders dropped from the list, -Uninstall removes every recorded one without repeating
-DenyPaths. -WhatIf/-PlanOnly print every step.
- After an apply, WARN for each protected-DACL item under a denied folder that the inherited deny cannot reach;
without -DenyPaths, WARN for pki/data/logs/backup/config/secrets siblings of InstallRoot.
Tests:
- Dry-run harness 46 -> 86 assertions (QA layout plan, mask bits, refusals, stale removal, record-driven
rollback, host account never denied). Mutations (no sibling deny, deny->allow, mask back to ReadData, no
stale removal, rollback ignoring the record, script-worker not refused) each turn it red.
- Test-ScriptWorkerIsolation.Windows.ps1 (Windows PowerShell 5.1, windev): 34/34, incl. -DenyPaths apply,
11/11 unchanged re-apply, shorter-list re-apply, uninstall from the record, second uninstall unchanged.
- New InstallerLayoutIsolationTests (OTOPCUA_ISOLATION_INSTALLER_E2E=1, elevated Windows): a scratch wonder
layout under the real restricted worker token. Before install and after uninstall the token reads pki/data/
logs/backup/appsettings and plants a trust-list file; installed it can do neither, still reads script-worker\,
a real worker launched from the layout runs a script, and the host still reads everything. Mutating the
-DenyPaths denies to a no-op mask turns it red on pki\own\private\otopcua.pfx (reproduces #890).
QA vq03/vq04 are NOT re-applied; the command is in docs/deploy/qa-upgrade-b8b4c18f-to-fea7de0a.md.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Owner scope 2026-11-12 (Windows x64 + Linux, unchanged cycle-3 caps, >=7200 s, SDK 1.5 comparator).
- Linux ARM64 (late-slope, 7200.12 s, 1964 cycles / 491 restarts, shutdown verified, analyzer-validated):
first rejection RSS at cycle 247 / 900.73 s, 358,682,624 > 358,678,528 (+4 KiB); peak 382.98 MiB vs
limit 342.06 MiB; late plateau medians 344.4/341.1/341.9 MiB, OLS -1.90 MiB/h. FAIL.
- Windows x64 on windev (same workload, working set as RSS, handle table as descriptors): first rejection RSS
at cycle 285 / 1130.76 s, 303,505,408 > 302,174,208; peak 319.49 vs limit 288.18 MiB; plateau ~314-315 MiB,
+0.93 MiB/h. FAIL. Also incomplete: the launcher's wall-clock outer deadline fired early after a +552 s
w32time step and ended the run at test-phase 7014 s (rejection had already latched); launchers now use a
Stopwatch.
- SDK 1.5.378.182 comparator (efb9197a publication, Windows, 7201 s): RSS peak +65.8 MiB (never over its cap),
plateau ~+48 MiB, but the +32 handle cap tripped at cycle 17 (max 674 vs 642).
- Managed flat on both SDK2 runs; growth is the generated-factory JIT burst (+40k/+44k methods) - Linux JIT
doublemapper ~180 MiB; Windows private bytes grew ~25 MiB of a ~132 MiB working-set rise.
- Retained: b61f3e05 cycle-1 fixture failure (#808 unplaced UNS folder), Windows/SDK1 smoke diagnostics.
No cap raised, no warm baseline, no failed run counted as passing.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Pins ZB.MOM.WW.LocalDb and .Replication at 0.3.7 (published 2026-11-12).
Wire-compatible; no code change needed.
- 0.3.6 (scadaproj#36): the library sync service enforces
LocalDb:Replication:ApiKey itself. LocalDbSyncAuthInterceptor is kept for
its refuse-every-stream-when-blank rule; doc comment updated. docker-dev
site-a pair: both nodes now read one variable,
OTOPCUA_SITE_A_LOCALDB_SYNC_KEY (same dev default as before), so an
override can never split the pair.
- 0.3.7 (scadaproj#16): a tombstone is held until the peer has it, so a
node offline past TombstoneRetention no longer brings a pruned
deployment back. The ledger grows while a peer is down; optional
TombstoneHardCap (documented in Configuration.md) bounds it.
Runbook, Configuration.md and the cluster-topology rule updated.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi