docs(heidenhain): class 3 / group 3 record from pyLSV2 #52; TNCcmd as the verification route (#853)
v2-ci / unit-tests (push) Has been cancelled
v2-ci / unit-tests (push) Has been cancelled
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
This commit is contained in:
@@ -324,7 +324,12 @@ public sources do establish:
|
||||
into the LSV2 class code, which is unconfirmed.
|
||||
- **Observed records (real iTNC 530, read-only).** class 7 / group 4 "Run test of cutout channels" (power-up self-test);
|
||||
class 7 / group 3 "701550 Cabin unlocked! B301" (Hermle70, Hermle29); class 1 / group 3 "700520 Tool life exceeded"
|
||||
(Hermle49). Both 7xxxxx records are machine-builder PET messages and both report group 3 — consistent with 3 = PLC.
|
||||
(Hermle49). Independently, pyLSV2 issue #52 (another user's iTNC 530) logged class 3 / group 3
|
||||
"010 Machine guard is open !" — a guard-open PLC message holding the program, which fits 3 = PGM HOLD **by meaning**,
|
||||
not just by numbering. All three machine-builder PET messages report group 3 — consistent with 3 = PLC.
|
||||
- **Verification route (read-only):** HEIDENHAIN's own TNCcmd `RUNINFO F` / `RUNINFO N` reads the same list and
|
||||
displays the class and group (pyLSV2 issue #13). Running it against a control and comparing its labels with our raw
|
||||
codes would check the table against vendor software instead of memory.
|
||||
- ⚠️ **"LSV2 shares the DNC numbering" is not a safe general assumption.** The DNC COM interface's `ExecutionMode`
|
||||
(0 MANUAL, 1 MDI, 2 RPF, 3 SINGLESTEP, 4 AUTOMATIC) matches LSV2 `R_RI 23`, but its `ProgramStatus` (0 IDLE,
|
||||
1 RUNNING, …) does **not** match LSV2 `R_RI 26` (0 Started … 7 Idle, which real controls confirm). So the class/group
|
||||
|
||||