docs(heidenhain): honest provenance for alarm class/group codes (#853)
v2-ci / unit-tests (push) Has been cancelled
v2-ci / unit-tests (push) Has been cancelled
No public source exists for DNC_ERROR_CLASS / DNC_ERROR_GROUP or their numbers (the table was written from memory). The iTNC 530 Technical Manual's PLC error table documents the same class and group NAMES without codes; three real iTNC 530 records corroborate 7/4, 7/3 and 1/3. DNC and LSV2 numberings are known to differ (ProgramStatus vs R_RI 26), so the numbers stay unproven. Docs/comments only; no behaviour change. Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
This commit is contained in:
@@ -370,7 +370,7 @@ panel with the NAT/IPv6-zone/loose-match caveats) / CLI `--validate-host-name`.
|
||||
allowlist is unchanged. FOCAS transition rules; identity = class+group+number+TEXT (numbers repeat, `-1`). A failed walk
|
||||
(refusal/overflow/comms) is quality-only, never a clear. ⚠️ Ack is LOCAL-ONLY (`AcknowledgeAsync` no-op success) —
|
||||
never add an LSV2 ack/write to the allowlist for it. Class/group codes have no invented SEVERITIES; since #839 they
|
||||
carry HEIDENHAIN DNC-interface names (labels + browse leaves only — corroborated by one iTNC 530 record, else
|
||||
carry class/group names (labels + browse leaves only; names per the iTNC 530 PET table, numbers from memory — corroborated by three iTNC 530 records, else
|
||||
hardware-unproven) and set the Part 9 `ConditionClass` (class 5 ⇒ Safety; group 1/2 ⇒ Process; 4/5 ⇒ System; else Base)
|
||||
via the new optional `AlarmEventArgs.ConditionClass` (projector keeps it across class-less events; node manager writes
|
||||
it; rebuild carries it). The browse picker offers `AlarmConditions/` selector leaves; alarms no selector claims are
|
||||
|
||||
@@ -311,12 +311,25 @@ are 0–65535 (wire uint16), NUMBER is int32. Selectors always filter on the **r
|
||||
`Alarms/Groups` or a condition message, then filter. One parser (`HeidenhainAlarmSelector`) backs the editor, the deploy
|
||||
inspector and the driver.
|
||||
|
||||
**Class / group names and the Part 9 condition class (Gitea #839).** LSV2 documents neither field (pyLSV2 and the Java
|
||||
port keep them raw). `HeidenhainAlarmClasses` carries HEIDENHAIN's own names from the **DNC interface** (RemoTools SDK
|
||||
`DNC_ERROR_CLASS` / `DNC_ERROR_GROUP`), which describe the same control error list. That the LSV2 codes share that
|
||||
numbering is corroborated by the one real record we hold — the captured iTNC 530 "Run test of cutout channels" is class 7
|
||||
`INFO`, group 4 `GENERAL`, a power-up self-test notice — and is otherwise **hardware-unproven** (the commissioning gate
|
||||
should confirm it on a live control).
|
||||
**Class / group names and the Part 9 condition class (Gitea #839, #853).** LSV2 documents neither field (pyLSV2 and the
|
||||
Java port keep them raw — pyLSV2's `decode_error_message` is class/group/number/text only). The names in
|
||||
`HeidenhainAlarmClasses` were originally written as the DNC interface's `DNC_ERROR_CLASS` / `DNC_ERROR_GROUP` enums
|
||||
**from memory**; a 2026-11-13 search found **no public source for those enums or their numeric values**. What the
|
||||
public sources do establish:
|
||||
|
||||
- **Names (vendor-documented, numbers not).** The iTNC 530 HSCI Technical Manual's PLC error table (`.PET`) has a
|
||||
**Class** column — ERROR (collective), FEED HOLD, PGM HOLD, PGM ABORT, EMERG. STOP, RESET — and a **Group** column —
|
||||
GENERAL, OPERATING, PROGRAMMING, PLC — plus a separate E/W/I message-type column. That is the same class set as our
|
||||
2–6 (and in the same order) and the same group set as our 1–4; WARNING/INFO/NOTE look like the message type folded
|
||||
into the LSV2 class code, which is unconfirmed.
|
||||
- **Observed records (real iTNC 530, read-only).** class 7 / group 4 "Run test of cutout channels" (power-up self-test);
|
||||
class 7 / group 3 "701550 Cabin unlocked! B301" (Hermle70, Hermle29); class 1 / group 3 "700520 Tool life exceeded"
|
||||
(Hermle49). Both 7xxxxx records are machine-builder PET messages and both report group 3 — consistent with 3 = PLC.
|
||||
- ⚠️ **"LSV2 shares the DNC numbering" is not a safe general assumption.** The DNC COM interface's `ExecutionMode`
|
||||
(0 MANUAL, 1 MDI, 2 RPF, 3 SINGLESTEP, 4 AUTOMATIC) matches LSV2 `R_RI 23`, but its `ProgramStatus` (0 IDLE,
|
||||
1 RUNNING, …) does **not** match LSV2 `R_RI 26` (0 Started … 7 Idle, which real controls confirm). So the class/group
|
||||
numbers stay **hardware-unproven** except where a record above shows them; the Safety branch (class 5) has never
|
||||
been observed.
|
||||
|
||||
| Class | 1 Warning · 2 FeedHold · 3 ProgramHold · 4 ProgramAbort · **5 EmergencyStop** · 6 Reset · 7 Info · 8 Error · 9 Note |
|
||||
|---|---|
|
||||
|
||||
@@ -8,11 +8,14 @@ namespace ZB.MOM.WW.OtOpcUa.Driver.Heidenhain;
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// <para><b>Provenance.</b> LSV2 itself documents neither field (pyLSV2 and the ignitionoee Java port keep them
|
||||
/// raw). The names are HEIDENHAIN's own error enums from the DNC interface (RemoTools SDK / HeidenhainDNC
|
||||
/// <c>DNC_ERROR_CLASS</c>, <c>DNC_ERROR_GROUP</c>), which describe the same control error list. That the LSV2
|
||||
/// <c>R_RI 27/28</c> codes use the same numbering is corroborated by the one real record we hold — the captured
|
||||
/// iTNC 530 alarm "Run test of cutout channels" is class 7 (<c>INFO</c>), group 4 (<c>GENERAL</c>), a power-up
|
||||
/// self-test notice — but is not otherwise proven on hardware. Treat the names as labels, never as behaviour:
|
||||
/// raw). The names were first written as the DNC interface's <c>DNC_ERROR_CLASS</c> /
|
||||
/// <c>DNC_ERROR_GROUP</c> enums from memory; no public source for those enums or their numbers was found
|
||||
/// (lmxopcua#853). The iTNC 530 Technical Manual's PLC error table documents the same NAMES (class: ERROR,
|
||||
/// FEED HOLD, PGM HOLD, PGM ABORT, EMERG. STOP, RESET; group: GENERAL, OPERATING, PROGRAMMING, PLC) but no
|
||||
/// numeric codes. Real iTNC 530 records corroborate class 7 / group 4, class 7 / group 3 and class 1 / group 3
|
||||
/// (both group-3 records are machine-builder PLC messages). The DNC and LSV2 numberings are known to differ
|
||||
/// elsewhere (program status), so the numbers stay hardware-unproven. Treat the names as labels, never as
|
||||
/// behaviour:
|
||||
/// they drive no selection and no severity (an authored <c>alarm.severity</c>, else High, still decides that).</para>
|
||||
/// <para><b>Part 9 mapping — only where the code says where the alarm comes from.</b>
|
||||
/// <c>EMERGENCY_STOP</c> (class 5) is a safety reaction ⇒ <see cref="AlarmConditionClass.Safety"/>, whatever its
|
||||
|
||||