docs(review): #761 Wave-4 gates re-run on current master (2026-11-12)
v2-ci / unit-tests (push) Has been cancelled
v2-ci / unit-tests (push) Has been cancelled
Re-ran every gate docker-dev and the fixtures can run, on master 412da27c plus the
deploy-API fix: A (now with dotnet-counters), B, C, D check 4 (after #785), E, H1
live end-to-end over OPC UA (N=0 year window: 6 pages <= 10k, continuation points,
all 52,560 values), the gate-F removal drop on the VD03 gateway (4 -> 2 within 15 s),
and all fixture lanes incl. the first G1 MTConnect run. All pass.
Recorded: the AbCip "writes" combination ran no writes (AB_DIFF_ENDPOINT gates them
off), a C-style pause past 15 s leaves a split SITE-B pair, and simulator evidence for
four of the five hardware userGates (TwinCAT has no simulator). The hardware
userGates stay open.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
This commit is contained in:
@@ -397,3 +397,190 @@ therefore not observed.** Re-check `mxgateway_sessions_open` once the VPN is bac
|
||||
`Deployment` rows carry only the `env:` reference, no secret.
|
||||
- All host nodes were recreated without the exported key, so `GALAXY_MXGW_API_KEY` is back to the committed
|
||||
docker-dev default. The rig runs `otopcua-host:dev` `sha256:47ca0da6eaf7` (`5ac55205`).
|
||||
|
||||
## Re-run on current master — all runnable gates (2026-11-12)
|
||||
|
||||
| | |
|
||||
|---|---|
|
||||
| Commit tested | `54c4357f` = `master` `412da27c` + the deploy-API fix below (landed on master as `fa8c3d1a` after a rebase over two unrelated commits; same diff). Image `otopcua-host:g761` `sha256:24432d7fbc2d`, built from that commit, on all six nodes. |
|
||||
| Rig | docker-dev as its **own compose project** `otopcua-g761` (an overlay remapping every host port and image tag), so the shared `otopcua-dev` rig that someone else was running was not touched. The ConfigDb was restored from a `COPY_ONLY` backup of the `otopcua-dev` ConfigDb (the same MAIN-modbus / MAIN-opcua / equipment `EQ-32296cc68964` + `okvt` config the 11-09 run used), then migrated (no pending migrations). Host ports: OPC UA 24840–24845, AdminUI 29200, per-node HTTP 29100–29105. |
|
||||
| Clock | Rig UTC 2026-11-13 03:05–03:44 (= 2026-11-12 evening US Eastern). |
|
||||
| Load | The 48 `int3b-mb-*` and the `int3b-blackhole` drivers were **disabled** after gate A. With them on, two rigs' worth of Modbus drivers saturated the shared pymodbus sim on 10.100.0.35 (about 117–136 % CPU) and `HR100` read `BadCommunicationError`. Gate D's 50-driver checks were not re-run (see D). |
|
||||
|
||||
**Summary: A, B, C, D (check 4), E, H1 (live), the F removal check and every fixture lane PASS. One product defect
|
||||
found and fixed (deploy API). Hardware userGates still open.**
|
||||
|
||||
### Defect found and fixed: a bodyless `POST /api/deployments` answered 404 — FIXED (`fa8c3d1a`)
|
||||
|
||||
The documented headless deploy (`docker-dev/deploy.sh`, README "Headless deploy") returned **404** on both centrals,
|
||||
while the same POST with a JSON body was accepted. The optional body was an inferred `DeployRequest?` parameter,
|
||||
which stamps `Accepts(application/json)` metadata on the endpoint. For a request with no `Content-Type` the routing
|
||||
`AcceptsMatcherPolicy` prefers endpoints that declare no consumes metadata. On a fused admin+driver host
|
||||
`MapOtOpcUaMeshGrpcServices` has mapped grpc-dotnet's `{unimplementedService}/{unimplementedMethod}` catch-all, so
|
||||
the request was routed away from the deploy handler and got a 404. The deploy API on its own does not reproduce
|
||||
it. The handler now reads the optional body itself: no body is the headless form, a non-JSON body answers 415 and
|
||||
malformed JSON 400. `DeployApiBodylessPostTests` (Host.IntegrationTests) composes the deploy API with the mesh gRPC
|
||||
services and drives real HTTP; with the fix reverted both bodyless cases fail with 404. Live on the rebuilt rig, a
|
||||
bodyless POST through Traefik answered **202** (every deploy below used it).
|
||||
|
||||
### Gate A (#731) — PASS, now with `dotnet-counters`
|
||||
|
||||
Method as on 11-09 (each iteration edits `MAIN-modbus` `TimeoutMs` and `MAIN-opcua` `SessionName`, deploys, waits for
|
||||
the seal + 8 s), 2 warm-ups + 20 iterations, every deploy sealed in 1–2 s. This time `dotnet-counters collect -p 1
|
||||
--counters System.Runtime --refresh-interval 5` (the linux-arm64 single-file tool copied into each central) ran for
|
||||
the whole loop, alongside `/proc/1` threads / fds / RSS.
|
||||
|
||||
| | central-1 | central-2 |
|
||||
|---|---|---|
|
||||
| `disposed Modbus driver on stop` / `disposed OpcUaClient driver on stop` | 20 / 20 | 20 / 20 |
|
||||
| `spawned … MAIN-modbus` / `MAIN-opcua` | 20 / 20 | 20 / 20 |
|
||||
| dispose/shutdown timeout or throw | 0 | 0 |
|
||||
| threads (baseline → range over 20 → settled 75 s later) | 54 → 49–57 → 48 | 53 → 48–56 → 46 |
|
||||
| open fds | 739 → 691–739 → 715 | 739 → 704–740 → 719 |
|
||||
| `dotnet.assembly.count` (57 / 54 samples) | 312, constant | 314, constant |
|
||||
| `dotnet.timer.count` first-quarter vs last-quarter mean | 139 → 137 | 144 → 145 |
|
||||
| `dotnet.thread_pool.thread.count` (UpDownCounter deltas) | net ≈ 0 | net ≈ 0 |
|
||||
| working set first-quarter vs last-quarter mean | 520 → 505 MB | 522 → 502 MB |
|
||||
|
||||
No upward trend in any series; nothing (assemblies, timers, threads, fds) accumulates per respawn. Raw CSVs:
|
||||
`counters-central-{1,2}.csv` in the run's evidence (not committed).
|
||||
|
||||
### Gate B (#732) — PASS
|
||||
|
||||
Same procedure as 11-09 on `opc.tcp://localhost:24840`, session 1 held 120 s on `ns=2;s=pymodbus/plc/HR100` and
|
||||
`ns=3;s=EQ-32296cc68964/okvt`.
|
||||
|
||||
- **Surgical add** (`HR101`, 03:14:27): both centrals logged `kind=PureAdd, added=1, … rebuild=False`. Each
|
||||
subscription took one `BadNoCommunication` sample at 03:14:27 and was Good again in the same second (the accepted
|
||||
driver respawn), then 21 / 22 Good updates until the rebuild. `HR101` itself reads `BadOutOfRange` (the fixture
|
||||
refuses address 101, as on 11-09).
|
||||
- **Rebuild** (rename `e1` → `e1r`, 03:14:49): `kind=Rebuild, … rebuild=True`; session 1's items got
|
||||
`BadNodeIdUnknown` and nothing after.
|
||||
- **Re-created after the rebuild** (session 2, 20 s): HR100 17 updates, okvt 16, **all Good**, none Bad.
|
||||
|
||||
### Gate C (#733) — PASS
|
||||
|
||||
- **C-a, kill `central-1` mid-dispatch.** `site-b-1` paused, deployment `56e5ede1` at `AwaitingApplyAcks` 5/6, `docker
|
||||
kill central-1` at 03:16:37. A second POST while in flight: **409**. After unpausing `site-b-1` the held
|
||||
deployment **sealed 6/6** (on 11-09 it timed out). After `central-1` restarted, the next deploy `6df32531`
|
||||
**sealed 6/6**.
|
||||
- **C-b, kill the singleton host.** `central-2` (the only `/health/active` 200 on MAIN) killed at 03:17:30 with
|
||||
`548ccbb9` in flight (5/6). `central-1` auto-downed it at 03:17:58, the singletons moved
|
||||
(`Younger -> BecomingOldest`), the AdminUI was back through Traefik at 03:18:02, and at 03:18:14 `central-1`
|
||||
logged `Coordinator recovered in-flight deployment 548ccbb9… (5/6 acks landed)`. It closed `TimedOut` with
|
||||
`failureReason` = `Timed out waiting for acks (5/6 landed). No ack from: site-b-1:4053. …` (the #784 fix,
|
||||
verified live). After `central-2` restarted, the next deploy `246594e0` **sealed 6/6**.
|
||||
- **C-port.** As on 11-09, a replacement container from the compose service with a `perl` listener holding
|
||||
`0.0.0.0:4840` before `dotnet OtOpcUa.Host.dll` starts (the 4840 socket inode belongs to perl, none to dotnet):
|
||||
- fused admin+driver (`central-2`): `GET /health/ready` **503**, `opcua-endpoint: Unhealthy — OPC UA SDK failed to
|
||||
start: Failed to establish tcp listener sockets on port 4840 for Ipv4 and IPv6.`; `configdb`/`akka` Healthy.
|
||||
- driver-only (`site-a-2`): `FTL OtOpcUaServerHostedService: SDK start failed on a driver-only node …`, **exit 1**.
|
||||
- So the C3 behaviour holds on OPC UA SDK 2.0.1. (A first attempt was invalid: the Perl one-liner did not keep the
|
||||
socket in a variable, so Perl closed it at once and the SDK bound 4840 normally. Re-run with the socket held.)
|
||||
- **Side effect worth knowing:** the 39 s `docker pause` of `site-b-1` in C-b outlived the 15 s auto-down, so
|
||||
`site-b-2` downed it and the SITE-B pair came back as **two 1-member clusters, both Active**, until `site-b-2`
|
||||
was restarted. That is the documented auto-down trade (`docs/Redundancy.md`, restart one side after the link
|
||||
heals), not a defect, but every C-style drill that pauses a node past 15 s leaves this behind.
|
||||
|
||||
### Gate D (#745) — check 4 re-run after #785: PASS
|
||||
|
||||
Checks 1, 2, 3 and 5 passed on 11-09 and their code is unchanged. Check 4, the one that failed, was re-run with
|
||||
Playwright against `http://localhost:29200` (login disabled), with a native-`confirm` listener armed (it never
|
||||
fired):
|
||||
|
||||
| page | Delete click | Cancel | Confirm |
|
||||
|---|---|---|---|
|
||||
| `/role-grants` (throwaway grant `cn=g761-gateD,…`) | modal "Delete role grant" naming the group; row still in DB | row kept | row deleted (0) |
|
||||
| `/clusters/SITE-B/acls/g761-acl` (throwaway ACL) | modal "Delete ACL"; row still in DB | row kept | row deleted (0) |
|
||||
| `/clusters/SITE-B/edit` | modal "Delete cluster 'SITE-B'? This cannot be undone." | modal closed, cluster kept | not confirmed (real row) |
|
||||
| `/clusters/SITE-B/nodes/site-b-2:4053` | modal "Delete node 'site-b-2:4053' from cluster 'SITE-B'? …" | modal closed, node kept | not confirmed (real row) |
|
||||
|
||||
### Gate E (#734) — PASS
|
||||
|
||||
`gateE-spin` (`var v = ctx.GetTag("pymodbus/plc/HR100").Value; while (true) { }`) as change-triggered virtual tag
|
||||
`spinvt` on `EQ-32296cc68964`, deployed 03:27:21, sampled every ~4 s for 1 min 50 s:
|
||||
|
||||
- **Quarantined** on both centrals at 03:27:42 (21.4 s / 22.3 s, over 10 × the 2 s budget); `/metrics`
|
||||
`otopcua_script_quarantined_total{reason="stuck",script="gateE-vt-spin"} 1`, `run_refused_total` 8 / 11. The
|
||||
main-log mirror now names the script (`[Script] gateE-vt-spin emitted Error …`, the #784 fix).
|
||||
- **Responsive:** `/health/ready` 200 in 2–6 ms throughout (2.9–3.5 ms before); `okvt` kept reading Good, connect +
|
||||
read 0.40–0.48 s (0.41–0.52 s before); `spinvt` `BadInternalError`.
|
||||
- **Threads flat:** central-1 42–44, central-2 41–45 (41–42 before).
|
||||
- CPU: both centrals went to ~1 core (≈100 ticks/s) until restarted after the gate — the known in-process limit
|
||||
(#750; the out-of-process runner is the fix).
|
||||
|
||||
### H1 (#736) — live end-to-end over OPC UA: PASS
|
||||
|
||||
This closes the 11-09 scope caveat (that run drove the backend directly). `ServerHistorian:Backend=SqlServer` on
|
||||
the centrals (DB `OtOpcUaHistorian` on the rig SQL), 52,560 samples (every 10 min, 2025-11-01 → 2026-10-31) seeded
|
||||
for `HR300` (`lg9.long`). A probe client (OPC UA SDK 2.0.1) sent `HistoryRead` raw with **`NumValuesPerNode = 0`**
|
||||
for the whole year on `opc.tcp://localhost:24840` and followed every continuation point:
|
||||
|
||||
| page | values | continuation point |
|
||||
|---|---|---|
|
||||
| 1 | 9,999 | 16 bytes |
|
||||
| 2–5 | 9,998 each | 16 bytes |
|
||||
| 6 | 2,569 | none |
|
||||
|
||||
52,560 values in total (= the seeded set: first 0, last 52559), timestamps strictly ascending, no duplicates,
|
||||
0.2 s. central-1 GC heap after the read: gen2 48 MB + LOH 56 MB + gen1 7 MB (≈ 112 MB), committed 170 MB — under the
|
||||
500 MB bound. QuestDb was not re-run live: the paging is the backend-agnostic node-manager `RawPageLimit` plan, and
|
||||
the QuestDb backend half passed on 11-09.
|
||||
|
||||
### Gate F (#735) — the removal drop, now observed: PASS
|
||||
|
||||
The 11-11 run could not see `mxgateway_sessions_open` return to baseline after removing the driver (the VPN
|
||||
dropped). The VD03 gateway has since restarted (its counters reset), so this was re-checked directly: a read-only
|
||||
`GalaxyMxGateway` driver `g761-gal` (one `Read` tag, `DevWinPlatform.ScanState`; key only as
|
||||
`env:GALAXY_MXGW_API_KEY`, sourced into the compose shell from the owner's env file and never written anywhere) was
|
||||
added to MAIN and then removed. Gateway `/metrics` (anonymous, scraped from the Mac):
|
||||
|
||||
| when (UTC) | open | opened_total | closed_total | workers |
|
||||
|---|---|---|---|---|
|
||||
| baseline 03:40:49–03:41:19 | 2 | 2 | – | 2 |
|
||||
| driver deployed 03:41:47 (both centrals `connected`, ScanState read Good) | **4** | 4 | – | 4 |
|
||||
| driver removed 03:42:58 → 03:43:13 … 03:43:59 | **2** | 4 | 2 | 2 |
|
||||
|
||||
Both centrals logged `stopped driver child g761-gal` + `disposed GalaxyMxGateway driver on stop`; the gateway
|
||||
closed both sessions within 15 s. No Galaxy writes, no alarm subscriptions.
|
||||
|
||||
### Driver fixture lanes (10.100.0.35) at `412da27c` — PASS
|
||||
|
||||
| Suite | Result | Notes |
|
||||
|---|---|---|
|
||||
| Modbus standard (:5020) | 12 / 0 / 32 | Two earlier attempts failed 8 then 1 tests on connect timeouts: the shared sim was saturated by this gate's own rig plus `otopcua-dev` (196 connections from this Mac). Clean once the load dropped. Skips are the other profiles. |
|
||||
| S7 s7_1500 (`S7_SIM_ALLOW_WRITES=1`) | 23 / 0 / 3 | Same 3 skips as 11-09 (TM/CT span limit, the two destructive CMD tests). |
|
||||
| AbCip controllogix, `AB_SERVER_ALLOW_WRITES=1 AB_DIFF_ENDPOINT=…` | 34 / 0 / 22 | **No write test runs in this combination**: `IntegrationWriteGate` refuses writes while `AB_DIFF_ENDPOINT` is set (read-only differential run). That was also true of the 11-09 "with writes" run. |
|
||||
| AbCip controllogix, `AB_SERVER_ALLOW_WRITES=1` only | 38 / 0 / 18 | The real write pass: all 10 write tests pass, incl. `AbCipRefusalLiveTests.A_whole_array_write_round_trips` (DINT[16]) and `AbCipUdtMemberWriteTests.A_member_array_element_write_leaves_the_other_elements_alone`, Native + libplctag. |
|
||||
| OpcUaClient (opc-plc :50000) | 9 / 0 / 0 | One flake on the first try (`ServerHostNameValidationTests…(validate: False)`, `BadRequestInterrupted`); clean rerun. |
|
||||
| OpcUaClient.Browser (+ `OPCUA_NAT_ENDPOINT=…:50010`) | 12 / 0 / 0 | The NAT fixture is up, so the #806 NAT tests ran too. |
|
||||
| MQTT + Sparkplug | 30 / 0 / 0 | |
|
||||
| Sql (SQL Server, PG, Oracle, blackhole) | 58 / 0 / 25 | 21 MySQL + 4 ODBC skips (no fixture). |
|
||||
| **MTConnect (G1, :5000)** | 21 / 0 / 0 | First run of the G1 MTConnect lane against the shared agent. |
|
||||
|
||||
### Hardware userGates — simulator evidence only; real hardware still required
|
||||
|
||||
| userGate | Simulator evidence (2026-11-12, `412da27c`) | Real hardware |
|
||||
|---|---|---|
|
||||
| AbCip array write | ab_server ControlLogix: whole-array DINT[16] round-trip + UDT member-array element write pass (above) | not run |
|
||||
| AbLegacy array write | ab_server SLC500 / MicroLogix / PLC-5: `N_file_array_write_round_trips_every_element` passes on all 3 families × 2 transports; AbLegacy suite 51 / 0 / 0 | not run (#752) |
|
||||
| TwinCAT array + STRING write | **none** — no ADS simulator exists (`elma-ads-tcp/udp` on 10.100.0.35 are socat relays to an absent ADS box); suite 0 / 0 / 18 skipped | not run (#755) |
|
||||
| FOCAS `MACRO:` > 32767 | `otopcua-focas-fixture` mock (byte-identical to the repo's `focas_mock/server.py`): `WireBackendCoverageTests.Macro_and_parameter_numbers_above_short_range_read_the_authored_variable` (`MACRO:99999`, `PARAM:40000`, with a decoy at the 16-bit-wrapped address) passes; FOCAS suite 18 / 0 / 0 | not run |
|
||||
| AbCip probe-typo recovery | `AbCipRefusalLiveTests.A_typod_probe_tag_does_not_black_out_a_reachable_device` passes on ab_server, Native + libplctag | not run |
|
||||
|
||||
Plan INT-4 marks these "USER-ORDERED — NON-SKIPPABLE … real ControlLogix / SLC / TwinCAT hardware", so the simulator
|
||||
passes do not close them. They need bench endpoints from the owner, or an explicit owner decision to accept the
|
||||
simulator evidence for the four that have it (TwinCAT has none).
|
||||
|
||||
### Observations
|
||||
|
||||
1. The bodyless-deploy 404 (fixed above) had been masked because every earlier gate run sent a JSON body.
|
||||
2. Two docker-dev rigs on one Mac saturate the shared pymodbus sim; disable the 48 `int3b-mb-*` drivers (they exist
|
||||
only for gate D's 50-driver checks) when not running those.
|
||||
|
||||
### Rig state left behind
|
||||
|
||||
The `otopcua-g761` project (containers, its volumes, the `otopcua-host:g761` / `otopcua-migrator:g761` images),
|
||||
the `g761-probe` network and the temporary `OtOpcUaHistorian` database (inside the project's SQL volume) were all
|
||||
removed. The shared `otopcua-dev` rig was only read (one `COPY_ONLY` backup to its container's `/tmp`, deleted
|
||||
straight after). Nothing was started or stopped on 10.100.0.35.
|
||||
|
||||