Commit Graph

313 Commits

Author SHA1 Message Date
Joseph Doherty
4d3ee47235 Auto: focas-f2d — PMC range coalescing
Closes #266
2026-04-25 20:02:10 -04:00
Joseph Doherty
63099115bf Auto: focas-f2c — PMC F/G for 16i
Capability-matrix correctness fix: real 16i ladders use F (CNC->PMC) and
G (PMC->CNC) signal groups for handshakes, but PmcLetters(Sixteen_i) was
returning {X,Y,R,D} only. Widen to {X,Y,F,G,R,D}; M/C/E/A/K/T remain
0i-F / 30i-only. Updated the matching test row.

Closes #265
2026-04-25 19:49:25 -04:00
Joseph Doherty
2f3eeecd17 Auto: focas-f2b — multi-path/multi-channel CNC
Adds optional `@N` path suffix to FocasAddress (PARAM:1815@2, R100@3.0,
MACRO:500@2, DIAG:280@2/1) with PathId defaulting to 1 for back-compat.
Per-device PathCount is discovered via cnc_rdpathnum at first connect and
cached on DeviceState; reads with PathId>PathCount return BadOutOfRange.
The driver issues cnc_setpath before each non-default-path read and
tracks LastSetPath so repeat reads on the same path skip the wire call.

Closes #264
2026-04-25 19:42:58 -04:00
Joseph Doherty
451b37a632 Auto: focas-f2a — DIAG: address scheme
New FocasAreaKind.Diagnostic parsed from DIAG:nnn (whole-CNC) and
DIAG:nnn/axis (per-axis), validated against a per-series
FocasCapabilityMatrix.DiagnosticRange table (16i: 0-499; 0i-F family:
0-999; 30i/31i/32i: 0-1023; Power Motion i: 0-255; Unknown: permissive
per existing matrix convention).

IFocasClient gains ReadDiagnosticAsync(diagNumber, axisOrZero, type,
ct) with a default returning BadNotSupported so older transport
variants degrade gracefully. FwlibFocasClient implements it via a new
cnc_rddiag P/Invoke that reuses the IODBPSD struct (same shape as
cnc_rdparam). FocasDriver.ReadAsync dispatches Diagnostic addresses
through the new path; non-Diagnostic kinds keep the existing
ReadAsync route unchanged.

Tests: parser positives (DIAG:1031, DIAG:280/2, case-insensitive,
zero, axis-8) + negatives (malformed, axis>31), capability matrix
boundaries per series, driver-level dispatch verifying axis index
threads through, init-time rejection on out-of-range, and
BadNotSupported fallback when the wire client doesn't override the
default. 266/266 pass in Driver.FOCAS.Tests.

Closes #263

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-25 19:31:49 -04:00
Joseph Doherty
0044603902 Auto: ablegacy-6 — ST string verification + length guard
Verifies libplctag's GetString/SetString round-trips ST file strings (1-word
length prefix + 82 ASCII bytes) end-to-end through the driver, and adds a
client-side length guard so over-82-char writes return BadOutOfRange instead
of being silently truncated by libplctag.

- LibplctagLegacyTagRuntime.EncodeValue: throws ArgumentOutOfRangeException
  for >82-char String writes (StFileMaxStringLength constant).
- AbLegacyDriver.WriteAsync: catches ArgumentOutOfRangeException and maps to
  BadOutOfRange.
- AbLegacyStringEncodingTests: 16 unit tests covering empty / 41-char /
  82-char / embedded-NUL / non-ASCII reads + writes; over-length writes
  return BadOutOfRange and never call WriteAsync; both Slc500 and Plc5
  family paths exercised.

Closes #249

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-25 19:18:55 -04:00
Joseph Doherty
286ab3ba41 Auto: ablegacy-5 — PD/MG/PLS/BT structure files
Adds PD (PID), MG (Message), PLS (Programmable Limit Switch) and BT
(Block Transfer) file types to the PCCC parser. New AbLegacyDataType
enum members (PidElement / MessageElement / PlsElement /
BlockTransferElement) plus per-type sub-element catalogue:

  - PD: SP/PV/CV/KP/KI/KD/MAXS/MINS/DB/OUT as Float32; EN/DN/MO/PE/
        AUTO/MAN/SP_VAL/SP_LL/SP_HL as Boolean (word-0 status bits).
  - MG: RBE/MS/SIZE/LEN as Int32; EN/EW/ER/DN/ST/CO/NR/TO as Boolean.
  - PLS: LEN as Int32 (bit table varies per PLC).
  - BT: RLEN/DLEN as Int32; EN/ST/DN/ER/CO/EW/TO/NR as Boolean.

Per-family flags on AbLegacyPlcFamilyProfile gate availability:

  - PD/MG: SLC500 + PLC-5 (operator + status bits both present).
  - PLS/BT: PLC-5 only (chassis-IO block transfer is PLC-5-specific).
  - MicroLogix + LogixPccc: rejected — no legacy file-letter form.

Status-bit indices match Rockwell DTAM / 1747-RM001 / 1785-6.5.12:
PD word 0 bits 0-8, MG/BT word 0 bits 8-15. PLC-set status bits
(PE/DN/SP_*; ST/DN/ER/CO/EW/NR/TO) are surfaced as ViewOnly via
IsPlcSetStatusBit, matching the Timer/Counter/Control pattern from
ablegacy-3.

LibplctagLegacyTagRuntime decodes PD non-bit members as Float32 and
MG/BT/PLS non-bit members as Int32; status bits route through GetBit
with the bit-position encoded by the driver via StatusBitIndex.

Tests: parser positive cases per family + negative cases per family,
catalogue + bit-index + read-only-bit assertions.

Closes #248
2026-04-25 19:08:51 -04:00
Joseph Doherty
e3c0750f7d Auto: abcip-2.6 — AOI input/output handling
AOI-aware browse paths: AOI instances now fan out under directional
sub-folders (Inputs/, Outputs/, InOut/) instead of a flat layout. The
sub-folders only appear when at least one member carries a non-Local
AoiQualifier, so plain UDT tags keep the pre-2.6 flat structure.

- Add AoiQualifier enum (Local / Input / Output / InOut) + new property
  on AbCipStructureMember (defaults to Local).
- L5K parser learns ADD_ON_INSTRUCTION_DEFINITION blocks; PARAMETER
  entries' Usage attribute flows through L5kMember.Usage.
- L5X parser captures the Usage attribute on <Parameter> elements.
- L5kIngest maps Usage strings (Input/Output/InOut) to AoiQualifier;
  null + unknown values map to Local.
- AbCipDriver.DiscoverAsync groups directional members under
  Inputs / Outputs / InOut sub-folders when any member is non-Local.
- Tests for L5K AOI block parsing, L5X Usage capture, ingest mapping
  (both formats), and AOI-vs-plain UDT discovery fan-out.

Closes #234
2026-04-25 18:58:49 -04:00
Joseph Doherty
6e244e0c01 Auto: abcip-2.5 — online tag-DB refresh trigger
Add IDriverControl capability interface in Core.Abstractions with a
RebrowseAsync(IAddressSpaceBuilder, CancellationToken) hook so operators
can force a controller-side @tags re-walk without restarting the driver.

AbCipDriver now implements IDriverControl. RebrowseAsync clears the UDT
template cache (so stale shapes from a pre-download program don't
survive) then runs the same enumerator + builder fan-out as
DiscoverAsync, serialised against concurrent discovery / rebrowse via
a new SemaphoreSlim.

Driver.AbCip.Cli ships a `rebrowse` subcommand mirroring the existing
probe / read shape: connects to a single gateway, runs RebrowseAsync
against an in-memory builder, and prints discovered tag names so
operators can sanity-check the controller's symbol table from a shell.

Tests cover: two consecutive RebrowseAsync calls bump the enumerator's
Create / Enumerate counters once each, discovered tags reach the
supplied builder, the template cache is dropped on rebrowse, and the
driver exposes IDriverControl. 313 AbCip unit tests + 17 CLI tests +
37 Core.Abstractions tests pass.

Closes #233
2026-04-25 18:45:48 -04:00
Joseph Doherty
08d8a104bb Auto: abcip-2.4 — CSV tag import/export
CsvTagImporter / CsvTagExporter parse and emit Kepware-format AB CIP tag
CSVs (Tag Name, Address, Data Type, Respect Data Type, Client Access,
Scan Rate, Description, Scaling). Import maps Tag Name → AbCipTagDefinition.Name,
Address → TagPath, Data Type → DataType, Description → Description,
Client Access → Writable. Skips blank rows + ;/# section markers; honours
column reordering via header lookup; RFC-4180-ish quoting.

CsvImports collection on AbCipDriverOptions mirrors L5kImports/L5xImports
and is consumed by InitializeAsync (declared > L5K > L5X > CSV precedence).

CLI tag-export command dumps the merged tag table from a driver-options JSON
to a Kepware CSV — runs the same import-merge precedence the driver uses but
without contacting any PLC.

Tests cover R/W mapping, blank-row skip, quoted comma, escaped quote, name
prefix, unknown-type fall-through, header reordering, and a load → export →
reparse round-trip.

Closes #232
2026-04-25 18:33:55 -04:00
Joseph Doherty
e5299cda5a Auto: abcip-2.3 — descriptions to OPC UA Description
Threads tag/UDT-member descriptions captured by the L5K (#346) and L5X
(#347) parsers through AbCipTagDefinition + AbCipStructureMember into
DriverAttributeInfo, so the address-space builder sets the OPC UA
Description attribute on each Variable node. L5kMember and L5xParser
also now capture per-member descriptions (via the (Description := "...")
attribute block on L5K and the <Description> child on L5X), and
L5kIngest forwards them. DriverNodeManager surfaces
DriverAttributeInfo.Description as the Variable's Description property.

Description is added as a trailing optional parameter on
DriverAttributeInfo (default null) so every other driver continues
to construct the record unchanged.

Closes #231
2026-04-25 18:23:31 -04:00
Joseph Doherty
cfcaf5c1d3 Auto: abcip-2.2 — L5X (XML) parser + ingest
Adds Import/L5xParser.cs that consumes Studio 5000 L5X (XML) controller
exports via System.Xml.XPath and produces the same L5kDocument bundle as
L5kParser, so L5kIngest handles both formats interchangeably.

- Controller-scope and program-scope <Tag> elements with Name, DataType,
  TagType, ExternalAccess, AliasFor, and <Description> child.
- <DataType>/<Members>/<Member> with Hidden BOOL-host (ZZZZZZZZZZ*) skip.
- AddOnInstructionDefinitions surfaced as L5kDataType entries so AOI-typed
  tags pick up a member layout the same way UDT-typed tags do; hidden
  EnableIn/EnableOut parameters skipped. Full directional Input/Output/InOut
  modelling stays deferred to PR 2.6.

AbCipDriverOptions gains parallel L5xImports collection (mirrors
L5kImports field-for-field). InitializeAsync funnels both through one
shared MergeImport helper that differs only in the parser delegate.

Tests: 8 L5X fixtures cover controller- and program-scope tags, alias skip,
UDT layout fan-out, AOI-typed tag, ZZZZZZZZZZ host skip, hidden AOI param
skip, missing-ExternalAccess default, and an empty-controller no-throw.

Closes #230
2026-04-25 18:10:53 -04:00
Joseph Doherty
86407e6ca2 Auto: abcip-2.1 — L5K parser + ingest
Pure-text parser for Studio 5000 L5K controller exports. Recognises
TAG/END_TAG, DATATYPE/END_DATATYPE, and PROGRAM/END_PROGRAM blocks,
strips (* ... *) comments, and tolerates multi-line entries + unknown
sections (CONFIG, MOTION_GROUP, etc.). Output records — L5kTag,
L5kDataType, L5kMember — feed L5kIngest which converts to
AbCipTagDefinition + AbCipStructureMember. Alias tags and
ExternalAccess=None tags are skipped per Kepware precedent.

AbCipDriverOptions gains an L5kImports collection
(AbCipL5kImportOptions records — file path or inline text + per-import
device + name prefix). InitializeAsync merges the imports into the
declared Tags map, with declared tags winning on Name conflicts so
operators can override import results without editing the L5K source.

Tests cover controller-scope TAG, program-scope TAG, alias-tag flag,
DATATYPE with member array dims, comment stripping, unknown-section
skipping, multi-line entries, and the full ingest path including
ExternalAccess=None / ReadOnly / UDT-typed tag fanout.

Closes #229

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-25 18:01:08 -04:00
Joseph Doherty
0df14ab94a Auto: twincat-1.5 — ENUM/ALIAS discovery
Resolve TwinCAT symbol data types via the IDataType chain instead of a
flat name match. ALIAS chains walk BaseType recursively (depth-capped at
16 against pathological cycles); ENUM surfaces its underlying integer
base type. POINTER / REFERENCE / INTERFACE / UNION / STRUCT / ARRAY / FB
remain explicitly out of scope and surface as null.

Closes #309
2026-04-25 17:48:45 -04:00
Joseph Doherty
b699052324 Auto: twincat-1.4 — whole-array reads
Surface int[]? ArrayDimensions on TwinCATTagDefinition + thread it through
ITwinCATClient.ReadValueAsync / WriteValueAsync. When non-null + non-empty,
AdsTwinCATClient issues a single ADS read against the symbol with
clrType.MakeArrayType() and returns the flat 1-D CLR Array; for IEC TIME /
DATE / DT / TOD element types we project per-element to the native
TimeSpan / DateTime so consumers see consistent types regardless of rank.

DiscoverAsync surfaces IsArray=true + ArrayDim=product(dims) onto
DriverAttributeInfo via a new ResolveArrayShape helper. Multi-dim shapes
flatten to the product on the wire — DriverAttributeInfo.ArrayDim is
single-uint today and the OPC UA layer reflects rank via its own metadata.

Native ADS notification subscriptions skip whole-array tags so the OPC UA
layer falls through to a polled snapshot — the per-element AdsNotificationEx
callback shape doesn't fit a flat array. Whole-array WRITES are out of
scope for this PR — AdsTwinCATClient.WriteValueAsync returns
BadNotSupported when ArrayDimensions is set.

Tests: TwinCATArrayReadTests covers ResolveArrayShape (null / empty /
single-dim / multi-dim flatten / non-positive defensive), DiscoverAsync
emitting IsArray + ArrayDim for declared array tags, single-dim + multi-dim
fake-client read fan-out, and the BadNotSupported gate on whole-array
writes. Existing 137 unit tests still pass — total now 143.

Closes #308
2026-04-25 17:36:15 -04:00
Joseph Doherty
fcf89618cd Auto: twincat-1.3 — bit-indexed BOOL writes (RMW)
Replace the NotSupportedException at AdsTwinCATClient.WriteValueAsync
for bit-indexed BOOL writes with a read-modify-write path:

  1. Strip the trailing .N selector from the symbol path.
  2. Read the parent as UDINT.
  3. Set or clear bit N via the standard mask.
  4. Write the parent back.

Concurrent bit writers against the same parent serialise through a
per-parent SemaphoreSlim cached in a ConcurrentDictionary (never
removed — bounded by writable-bit-tag cardinality). Mirrors the AbCip /
Modbus / FOCAS bit-RMW pattern shipped in #181 pass 1.

The path-stripping (TryGetParentSymbolPath) and mask helper (ApplyBit)
are exposed as internal statics so tests can pin the pure logic without
needing a real ADS target. The FakeTwinCATClient mirrors the same RMW
semantics so driver-level round-trip tests assert the parent-word state.

Closes #307
2026-04-25 17:22:59 -04:00
Joseph Doherty
80b2d7f8c3 Auto: twincat-1.2 — native UA TIME/DATE/DT/TOD
IEC 61131-3 TIME/TOD now surface as TimeSpan (UA Duration); DATE/DT
surface as DateTime (UTC). The wire form stays UDINT — AdsTwinCATClient
post-processes raw values in ReadValueAsync and OnAdsNotificationEx,
and accepts native CLR types in ConvertForWrite. Added Duration to
DriverDataType (back-compat: existing switches default to BaseDataType
for unknown enum values) and mapped it to DataTypeIds.Duration in
DriverNodeManager.

Closes #306
2026-04-25 17:14:12 -04:00
Joseph Doherty
615ab25680 Auto: twincat-1.1 — Int64 fidelity for LINT/ULINT
Map LInt/ULInt to DriverDataType.Int64/UInt64 instead of truncating
to Int32. AdsTwinCATClient.MapToClrType already returns long/ulong
so the wire-level read returns the correct boxed types.

Closes #305
2026-04-25 17:04:43 -04:00
Joseph Doherty
e5122c546b Auto: s7-a5 — LOGO!/S7-200 V-memory parser
Add CPU-aware overload S7AddressParser.Parse(string, CpuType?) that
accepts the V area letter for S7-200 / S7-200 Smart / LOGO! 0BA8 and
maps it to DataBlock DB1. V is rejected on S7-300/400/1200/1500 and on
the legacy CPU-agnostic Parse(string) overload. Width suffixes mirror
M/I/Q (VB/VW/VD/V0.0). S7Driver passes _options.CpuType so live tag
config picks up family-aware parsing.

Tests cover S7200/S7200Smart/Logo0BA8 positive cases, modern-family
rejection, and CPU-agnostic rejection.

Closes #291
2026-04-25 16:58:34 -04:00
Joseph Doherty
ce98c2ada3 Auto: s7-a4 — array tags (ValueRank=1)
- S7TagDefinition gets optional ElementCount; >1 marks the tag as a 1-D array.
- ReadOneAsync / WriteOneAsync: one byte-range Read/WriteBytesAsync covering
  N × elementBytes, sliced/packed client-side via the existing big-endian scalar
  codecs and S7DateTimeCodec.
- DiscoverAsync surfaces IsArray=true and ArrayDim=ElementCount → ValueRank=1.
- Init-time validation (now ahead of TCP open) caps ElementCount at 8000 and
  rejects unsupported element types: STRING/WSTRING/CHAR/WCHAR (variable-width)
  and BOOL (packed-bit layout) — both follow-ups.
- Supported element types: Byte, Int16/UInt16, Int32/UInt32, Int64/UInt64,
  Float32, Float64, Date, Time, TimeOfDay.

Closes #290
2026-04-25 16:49:02 -04:00
Joseph Doherty
2b66cec582 Auto: s7-a3 — DTL/DT/S5TIME/TIME/TOD/DATE codecs
Adds S7DateTimeCodec static class implementing the six Siemens S7 date/time
wire formats:

  - DTL (12 bytes): UInt16 BE year + month/day/dow/h/m/s + UInt32 BE nanos
  - DATE_AND_TIME (8 bytes BCD): yy/mm/dd/hh/mm/ss + 3-digit BCD ms + dow
  - S5TIME (16 bits): 2-bit timebase + 3-digit BCD count → TimeSpan
  - TIME (Int32 ms BE, signed) → TimeSpan, allows negative durations
  - TOD (UInt32 ms BE, 0..86399999) → TimeSpan since midnight
  - DATE (UInt16 BE days since 1990-01-01) → DateTime

Mirrors the S7StringCodec pattern from PR-S7-A2 — codecs operate on raw byte
spans so each format can be locked with golden-byte unit tests without a
live PLC. New S7DataType members (Dtl, DateAndTime, S5Time, Time, TimeOfDay,
Date) are wired into S7Driver.ReadOneAsync/WriteOneAsync via byte-level
ReadBytesAsync/WriteBytesAsync calls — S7.Net's string-keyed Read/Write
overloads have no syntax for these widths.

Uninitialized PLC buffers (all-zero year+month for DTL/DT) reject as
InvalidDataException → BadOutOfRange to operators, rather than decoding as
year-0001 garbage.

S5TIME / TIME / TOD surface as Int32 ms (DriverDataType has no Duration);
DTL / DT / DATE surface as DriverDataType.DateTime.

Test coverage: 30 new golden-vector + round-trip + rejection tests,
including the all-zero buffer rejection paths and BCD-nibble validation.
Build clean, 115/115 S7 tests pass.

Closes #289

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-25 16:37:39 -04:00
Joseph Doherty
316f820eff Auto: s7-a2 — STRING/WSTRING/CHAR/WCHAR
Closes the NotSupportedException cliff for S7 string-shaped types.

- S7DataType gains WString, Char, WChar members alongside the existing
  String entry.
- New S7StringCodec encodes/decodes the four wire formats:
    STRING  : 2-byte header (max-len + actual-len bytes) + N ASCII bytes
              -> total 2 + max_len.
    WSTRING : 4-byte header (max-len + actual-len UInt16 BE) + N×2
              UTF-16BE bytes -> total 4 + 2 × max_len.
    CHAR    : 1 ASCII byte (rejects non-ASCII on encode).
    WCHAR   : 2 UTF-16BE bytes.
  Header-bug clamp: actualLen > maxLen is silently clamped on read so
  firmware quirks don't walk past the wire buffer; rejected on write
  to avoid silent truncation.
- S7Driver.ReadOneAsync / WriteOneAsync issue ReadBytesAsync /
  WriteBytesAsync against the parsed Area / DbNumber / ByteOffset and
  honour S7TagDefinition.StringLength (default 254 = S7 STRING max).
- MapDataType returns DriverDataType.String for the three new enum
  members so OPC UA discovery surfaces them as scalar strings.

Tests: 21 new cases on S7StringCodec covering golden-byte vectors,
encode/decode round-trips, the firmware-bug header-clamp, ASCII-only
guard on CHAR, and the StringLength default. 85/85 passing.

Closes #288
2026-04-25 16:26:05 -04:00
Joseph Doherty
d1699af609 Auto: s7-a1 — 64-bit scalar types
Closes the NotSupportedException cliff for S7 Float64/Int64/UInt64.

- S7Size enum gains LWord (8 bytes); parser accepts DBLD/DBL on data
  blocks and LD on M/I/Q (e.g. DB1.DBLD0, DB1.DBL8, MLD0, ILD8, QLD16).
- S7Driver.ReadOneAsync / WriteOneAsync issue ReadBytesAsync /
  WriteBytesAsync for 64-bit types and convert big-endian via
  System.Buffers.Binary.BinaryPrimitives. S7's wire format is BE.
- Internal MapArea(S7Area) helper translates to S7.Net DataType.
- MapDataType now surfaces native DriverDataType for Int16/UInt16/
  UInt32/Int64/UInt64 instead of collapsing them all to Int32.

Tests: parser theories cover DBLD/DBL/MLD/ILD/QLD; discovery test
asserts the 64-bit DriverDataType mapping. 64/64 passing.

Closes #287
2026-04-25 16:16:23 -04:00
Joseph Doherty
4a3860ae92 Auto: opcuaclient-5 — CRL/revocation handling
Adds explicit revoked-vs-untrusted distinction to the OpcUaClient driver's
server-cert validation hook, plus three new knobs on a new
OpcUaCertificateValidationOptions sub-record:

  RejectSHA1SignedCertificates  (default true — SHA-1 is OPC UA spec-deprecated;
                                 this is a deliberately tighter default)
  RejectUnknownRevocationStatus (default false — keeps brownfield deployments
                                 without CRL infrastructure working)
  MinimumCertificateKeySize     (default 2048)

The validator hook now runs whether or not AutoAcceptCertificates is set:
revoked / issuer-revoked certs are always rejected with a distinct
"REVOKED" log line; SHA-1 + small-key certs are rejected per policy;
unknown-revocation gates on the new flag; untrusted still honours
AutoAccept.

Decision pipeline factored into a static EvaluateCertificateValidation
helper with a CertificateValidationDecision record so unit tests cover
all branches without needing to spin up an SDK CertificateValidator.

CRL files themselves: the OPC UA SDK reads them automatically from the
crl/ subdir of each cert store — no driver-side wiring needed.
Documented on the new options record.

Tests (12 new) cover defaults, every branch of the decision pipeline,
SHA-1 detection (custom X509SignatureGenerator since .NET 10's
CreateSelfSigned refuses SHA-1), and key-size detection. All 127
OpcUaClient unit tests still pass.

Closes #277

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-25 16:05:50 -04:00
Joseph Doherty
bb1ab47b68 Auto: opcuaclient-4 — diagnostics counters
Per-driver counters surfaced via DriverHealth.Diagnostics for the
driver-diagnostics RPC. New OpcUaClientDiagnostics tracks
PublishRequestCount, NotificationCount, NotificationsPerSecond (5s-half-life
EWMA), MissingPublishRequestCount, DroppedNotificationCount,
SessionResetCount and LastReconnectUtcTicks via Interlocked on the hot path.

DriverHealth gains an optional IReadOnlyDictionary<string,double>?
Diagnostics parameter (defaulted null for back-compat with the seven other
drivers' constructors). OpcUaClientDriver wires Session.Notification +
Session.PublishError on connect and on reconnect-complete (recording a
session-reset there); GetHealth snapshots the counters on every poll so the
RPC sees fresh values without a tick source.

Tests: 11 new OpcUaClientDiagnosticsTests cover counter increments, EWMA
convergence, snapshot shape, GetHealth integration, and DriverHealth
back-compat. Full OpcUaClient.Tests 115/115 green.

Closes #276

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-25 15:53:57 -04:00
Joseph Doherty
494fdf2358 Auto: opcuaclient-3 — honor server OperationLimits
Closes #275
2026-04-25 15:38:55 -04:00
Joseph Doherty
fae00749ca Auto: opcuaclient-2 — per-tag advanced subscription tuning
Closes #274
2026-04-25 15:25:20 -04:00
Joseph Doherty
7209364c35 Auto: opcuaclient-1 — per-subscription tuning
Closes #273
2026-04-25 15:09:08 -04:00
Joseph Doherty
1abf743a9f Auto: focas-f1f — figure scaling + diagnostics
Closes #262
2026-04-25 15:01:37 -04:00
Joseph Doherty
cc757855e6 Auto: focas-f1e — operator messages + block text
Closes #261
2026-04-25 14:49:11 -04:00
Joseph Doherty
9ec92a9082 Auto: focas-f1d — Tool number + work coordinate offsets
Closes #260
2026-04-25 14:37:51 -04:00
Joseph Doherty
3c2c4f29ea Auto: focas-f1c — Modal codes + overrides
Closes #259

Adds Modal/ + Override/ fixed-tree subfolders per FOCAS device, mirroring the
pattern established by Status/ (#257) and Production/ (#258): cached snapshots
refreshed on the probe tick, served from cache on read, no extra wire traffic
on top of user-driven tag reads.

Modal/ surfaces the four universally-present aux modal codes M/S/T/B from
cnc_modal(type=100..103) as Int16. **G-group decoding (groups 1..21) is deferred
to a follow-up** — the FWLIB ODBMDL union differs per series + group and the
issue body explicitly permits this scoping. Adds the cnc_modal P/Invoke +
ODBMDL struct + a generic int16 cnc_rdparam helper so the follow-up can add
G-groups without further wire-level scaffolding.

Override/ surfaces Feed/Rapid/Spindle/Jog from cnc_rdparam at MTB-specific
parameter numbers (FocasDeviceOptions.OverrideParameters; defaults to 30i:
6010/6011/6014/6015). Per-field nullable params let a deployment hide overrides
their MTB doesn't wire up; passing OverrideParameters=null suppresses the entire
Override/ subfolder for that device.

6 unit tests cover discovery shape, omitted Override folder when unconfigured,
partial Override field selection, cached-snapshot reads (Modal + Override),
BadCommunicationError before first refresh, and the FwlibFocasClient
disconnected short-circuit.
2026-04-25 14:26:48 -04:00
Joseph Doherty
3d9697b918 Auto: focas-f1b — parts count + cycle time
Closes #258
2026-04-25 14:14:54 -04:00
Joseph Doherty
551494d223 Auto: focas-f1a — ODBST status flags as fixed-tree nodes
Closes #257
2026-04-25 14:05:12 -04:00
Joseph Doherty
4ff4cc5899 Auto: ablegacy-4 — indirect/indexed addressing parser
Closes #247
2026-04-25 13:51:03 -04:00
Joseph Doherty
c89f5bb3b9 Auto: ablegacy-3 — sub-element bit semantics
Closes #246
2026-04-25 13:41:52 -04:00
Joseph Doherty
f2bc36349e Auto: ablegacy-2 — MicroLogix function-file letters
Closes #245
2026-04-25 13:32:23 -04:00
Joseph Doherty
8f7265186d Auto: ablegacy-1 — PLC-5 octal I/O addressing
Closes #244
2026-04-25 13:25:22 -04:00
Joseph Doherty
36b2929780 Auto: abcip-1.4 — CIP multi-tag write packing
Group writes by device through new AbCipMultiWritePlanner; for families that
support CIP request packing (ControlLogix / CompactLogix / GuardLogix) the
packable writes for one device are dispatched concurrently so libplctag's
native scheduler can coalesce them onto one Multi-Service Packet (0x0A).
Micro800 keeps SupportsRequestPacking=false and falls back to per-tag
sequential writes. BOOL-within-DINT writes are excluded from packing and
continue to go through the per-parent RMW semaphore so two concurrent bit
writes against the same DINT cannot lose one another's update.

The libplctag .NET wrapper does not expose a Multi-Service Packet construction
API at the per-Tag surface (each Tag is one CIP service), so this PR uses
client-side coalescing — concurrent Task.WhenAll dispatch per device — rather
than building raw CIP frames. The native libplctag scheduler does pack
concurrent same-connection writes when the family allows it, which gives the
round-trip reduction #228 calls for without ballooning the diff.

Per-tag StatusCodes preserve caller order across success, transport failure,
non-writable tags, unknown references, and unknown devices, including in
mixed concurrent batches.

Closes #228
2026-04-25 13:14:28 -04:00
Joseph Doherty
767ac4aec5 Auto: abcip-1.3 — array-slice read addressing
Closes #227
2026-04-25 13:03:45 -04:00
Joseph Doherty
d78a471e90 Auto: abcip-1.2 — STRINGnn variant decoding
Closes #226

Adds nullable StringLength to AbCipTagDefinition + AbCipStructureMember
so STRING_20 / STRING_40 / STRING_80 UDT variants decode against the
right DATA-array capacity. The configured length threads through a new
StringMaxCapacity field on AbCipTagCreateParams and lands on the
libplctag Tag.StringMaxCapacity attribute (verified property on
libplctag 1.5.2). Null leaves libplctag's default 82-byte STRING in
place for back-compat. Driver gates on DataType == String so a stray
StringLength on a DINT tag doesn't reshape that buffer. UDT member
fan-out copies StringLength from the AbCipStructureMember onto the
synthesised member tag definition.

Tests: 4 new in AbCipDriverReadTests covering threaded StringMaxCapacity,
the null back-compat path, the non-String gate, and the UDT-member fan-out.
2026-04-25 12:53:20 -04:00
Joseph Doherty
2e6228a243 Auto: abcip-1.1 — LINT/ULINT 64-bit fidelity
Closes #225
2026-04-25 12:44:43 -04:00
Joseph Doherty
2ec6aa480e Task #219 — OpcUaServerOptions.AnonymousRoles (5/5 e2e stages pass)
Anonymous OPC UA sessions had no roles (`UserIdentity()`), so
`WriteAuthzPolicy.IsAllowed(SecurityClassification.Operate, [])`
rejected every write with `BadUserAccessDenied`. The reverse-write
stage of the Modbus e2e script surfaced this: stages 1-3 + 5 pass
forward-direction, stage 4 (OPC UA client → server → driver → PLC)
blew up with `0x801F0000` even with the factory + seed perfectly
wired.

Adds a single config knob:

    "OpcUaServer": {
      "AnonymousRoles": ["WriteOperate"]
    }

Default empty preserves the pre-existing production-safe behaviour
(anonymous reads FreeAccess tags, rejected on everything else). When
non-empty, `OtOpcUaServer.OnImpersonateUser` wraps the anonymous token
in a `RoleBasedIdentity("(anonymous)", "Anonymous", AnonymousRoles)`
so the server-layer write guard sees the configured roles.

Wire-through:
 - OpcUaServerOptions.AnonymousRoles (new)
 - OpcUaApplicationHost passes it to OtOpcUaServer ctor
 - OtOpcUaServer new anonymousRoles ctor param + OnImpersonateUser
   branch
 - Program.cs reads `OpcUaServer:AnonymousRoles` section from config

Env override syntax: `OpcUaServer__AnonymousRoles__0=WriteOperate`.

## Verified live

Booted server against `seed-modbus-smoke.sql` with
`OpcUaServer__AnonymousRoles__0=WriteOperate` + pymodbus fixture →
`test-modbus.ps1 -BridgeNodeId "ns=2;s=HR200"`:

    === Modbus e2e summary: 5/5 passed ===
    [PASS] Probe
    [PASS] Driver loopback
    [PASS] Server bridge            (driver → server → client)
    [PASS] OPC UA write bridge      (client → server → driver)
    [PASS] Subscribe sees change

All five stages green end-to-end. Issue #219 closed by this PR; the
Modbus-seed update to set AnonymousRoles lives in the follow-up #220
live-boot PR (same AnonymousRoles value applies to every driver since
the classification is a driver-constant, not per-tag).

Full-solution build: 0 errors, only pre-existing xUnit1051 warnings.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 11:49:41 -04:00
Joseph Doherty
7ba783de77 Tasks #211 #212 #213 — AbCip / S7 / AbLegacy server-side factories + seed SQL
Parent: #209. Follow-up to #210 (Modbus). Registers the remaining three
non-Galaxy driver factories so a Config DB `DriverType` in
{`AbCip`, `S7`, `AbLegacy`} actually boots a live driver instead of
being silently skipped by DriverInstanceBootstrapper.

Each factory follows the same shape as ModbusDriverFactoryExtensions +
the existing Galaxy + FOCAS patterns:
 - Static `Register(DriverFactoryRegistry)` entry point.
 - Internal `CreateInstance(driverInstanceId, driverConfigJson)` —
   deserialises a DTO, strict-parses enum fields (fail-fast with an
   explicit "expected one of" list), composes the driver's options object,
   returns a new driver.
 - DriverType keys: `"AbCip"`, `"S7"`, `"AbLegacy"` (case-insensitive at
   the registry layer).

DTO surfaces cover every option the respective driver's Options class
exposes — devices, tags, probe, timeouts, per-driver quirks
(AbCip `EnableControllerBrowse` / `EnableAlarmProjection`, S7 Rack/Slot/
CpuType, AbLegacy PlcFamily).

Seed SQL (mirrors `seed-modbus-smoke.sql` shape):
 - `seed-abcip-smoke.sql` — `abcip-smoke` cluster + ControlLogix device +
   `TestDINT:DInt` tag, pointing at the ab_server compose fixture
   (`ab://127.0.0.1:44818/1,0`).
 - `seed-s7-smoke.sql` — `s7-smoke` cluster + S71500 CPU + `DB1.DBW0:Int16`
   tag at the python-snap7 fixture (`127.0.0.1:1102`, non-priv port).
 - `seed-ablegacy-smoke.sql` — `ablegacy-smoke` cluster + SLC 500 + `N7:5`
   tag. Hardware-gated per #222; placeholder gateway to be replaced with
   real SLC/MicroLogix/PLC-5/RSEmulate before running.

Build plumbing:
 - Each driver project now ProjectReferences `Core` (was
   `Core.Abstractions`-only). `DriverFactoryRegistry` lives in `Core.Hosting`
   so the factory extensions can't compile without it. Matches the FOCAS +
   Galaxy.Proxy reference shape.
 - `Server.csproj` adds the three new driver ProjectReferences so Program.cs
   resolves the symbols at compile-time + ships the assemblies at runtime.

Full-solution build: 0 errors, 334 pre-existing xUnit1051 warnings only.

Live boot verification of all four (Modbus + these three) happens in the
exit-gate PR — factories + seeds are pre-conditions and are being
shipped first so the exit-gate PR can scope to "does the server publish
the expected NodeIds + does the e2e script pass."

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 11:15:38 -04:00
Joseph Doherty
55245a962e Task #210 — Modbus server-side factory + seed SQL (closes first of #209 umbrella)
Parent: #209. Adds the server-side wiring so a Config DB `DriverType='Modbus'`
row actually boots a Modbus driver instance + publishes its tags under OPC UA
NodeIds, instead of being silently skipped by DriverInstanceBootstrapper.

Changes:
 - `ModbusDriverFactoryExtensions` (new) — mirrors
   `GalaxyProxyDriverFactoryExtensions` + `FocasDriverFactoryExtensions`.
   `DriverTypeName="Modbus"`, `CreateInstance` deserialises
   `ModbusDriverConfigDto` (Host/Port/UnitId/TimeoutMs/Probe/Tags) to a full
   `ModbusDriverOptions` and hands back a `ModbusDriver`. Strict enum parsing
   (Region / DataType / ByteOrder / StringByteOrder) — unknown values fail
   fast with an explicit "expected one of" error rather than at first read.
 - `Program.cs` — register the factory after Galaxy + FOCAS.
 - `Driver.Modbus.csproj` — add `Core` project reference (the DI-free factory
   needs `DriverFactoryRegistry` from `Core.Hosting`). Matches the FOCAS
   driver's reference shape.
 - `Server.csproj` — add the `Driver.Modbus` ProjectReference so the
   Program.cs registration compiles against the same assembly the server
   loads at runtime.
 - `scripts/smoke/seed-modbus-smoke.sql` (new) — one-cluster smoke seed
   modelled on `seed-phase-7-smoke.sql`. Creates a `modbus-smoke` cluster +
   `modbus-smoke-node` + Draft generation + Namespace + UnsArea/UnsLine/
   Equipment + one Modbus `DriverInstance` pointing at the pymodbus standard
   fixture (`127.0.0.1:5020`) + one Tag at `HR[200]:UInt16`, ending in
   `EXEC sp_PublishGeneration`. HR[100] is deliberately *not* used because
   pymodbus `standard.json` runs an auto-increment action on that register.

Full-solution build: 0 errors, only the pre-existing xUnit1051 warnings.

AB CIP / S7 / AB Legacy factories follow in their own PRs per #211 / #212 /
#213. Live boot verification happens in the exit-gate PR once all four
factories are in place.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 11:06:08 -04:00
Joseph Doherty
8d92e00e38 Task #253 — E2E CLI test scripts + FOCAS test-client CLI
The driver-layer integration tests confirm the driver sees the PLC, and
the Client.CLI tests confirm the client sees the server. Nothing glued
them end-to-end until this PR.

- scripts/e2e/_common.ps1: shared helpers — CLI invocation (published-
  binary OR `dotnet run` fallback), Test-Probe / Test-DriverLoopback /
  Test-ServerBridge (all return @{Passed;Reason} hashtables).
- scripts/e2e/test-<modbus|abcip|ablegacy|s7|focas|twincat>.ps1: per-
  driver three-stage script (probe → driver-loopback → server-bridge).
  AB Legacy / FOCAS / TwinCAT are gated behind *_TRUST_WIRE env vars
  since they need real hardware (#222) or a licensed runtime (#221).
- scripts/e2e/test-phase7-virtualtags.ps1: writes a Modbus HR, reads
  the server-side VirtualTag (VT = input * 2) back via OPC UA, triggers
  + clears a scripted alarm. Exercises the Phase 7 CachedTagUpstreamSource
  + ScriptedAlarmEngine path.
- scripts/e2e/test-all.ps1: reads e2e-config.json sidecar, runs each
  present driver, prints a FINAL MATRIX (PASS/FAIL/SKIP). Missing
  sections SKIP rather than fail hard.
- scripts/e2e/e2e-config.sample.json: commented sample — each dev's
  NodeIds are local-seed-specific so e2e-config.json is .gitignore-d.
- scripts/e2e/README.md: full walkthrough — prereqs, three-stage design,
  env-var gates, expected matrix, why this is separate from `dotnet test`.

Tasks #249-#251 shipped Modbus/AbCip/AbLegacy/S7/TwinCAT CLIs but left
FOCAS out. Since test-focas.ps1 needs it, the 6th CLI ships here:

- src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Cli: probe/read/write/subscribe
  commands, AssemblyName `otopcua-focas-cli`. WriteCommand.ParseValue
  handles the full FocasDataType enum (Bit/Byte/Int16/Int32/Float32/
  Float64/String — no UInt variants; the FOCAS protocol exposes signed
  PMC + Fanuc-Float only). Default DataType is Int16 to match the PMC
  register convention.

Full-solution build clean (0 errors). FOCAS CLI wired into
ZB.MOM.WW.OtOpcUa.slnx. No .Tests project for the FOCAS CLI yet —
symmetric with how ProbeCommand has no unit-testable pure logic in the
other 5 CLIs either; WriteCommand.ParseValue parity will land in a
follow-up to keep this PR scoped.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 09:51:13 -04:00
Joseph Doherty
4dc685a365 Task #251 — S7 + TwinCAT test-client CLIs (driver CLI suite complete)
Final two of the five driver test clients. Pattern carried forward from
#249 (Modbus) + #250 (AB CIP, AB Legacy) — each CLI inherits Driver.Cli.Common
for DriverCommandBase + SnapshotFormatter and adds a protocol-specific
CommandBase + 4 commands (probe / read / write / subscribe).

New projects:
  - src/ZB.MOM.WW.OtOpcUa.Driver.S7.Cli/ — otopcua-s7-cli.
    S7CommandBase carries host/port/cpu/rack/slot/timeout. Handles all S7
    atomic types (Bool, Byte, Int16..UInt64, Float32/64, String, DateTime).
    DateTime parses via RoundtripKind so "2026-04-21T12:34:56Z" works.
  - src/ZB.MOM.WW.OtOpcUa.Driver.TwinCAT.Cli/ — otopcua-twincat-cli.
    TwinCATCommandBase carries ams-net-id + ams-port + --poll-only toggle
    (flips UseNativeNotifications=false). Covers the full IEC 61131-3
    atomic set: Bool, SInt/USInt, Int/UInt, DInt/UDInt, LInt/ULInt, Real,
    LReal, String, WString, Time/Date/DateTime/TimeOfDay. Structure writes
    refused as out-of-scope (same as AB CIP). IEC time/date variants marshal
    as UDINT on the wire per IEC spec. Subscribe banner announces "ADS
    notification" vs "polling" so the mechanism is obvious in bug reports.

Tests (49 new, 122 cumulative driver-CLI):
  - S7: 22 tests. Every S7DataType has a happy-path + bounds case. DateTime
    round-trips an ISO-8601 string. Tag-name synthesis round-trips every
    S7 address form (DB / M / I / Q, bit/word/dword, strings).
  - TwinCAT: 27 tests. Full IEC type matrix including WString UTF-8 pass-
    through + the four IEC time/date variants landing on UDINT. Structure
    rejection case. Tag-name synthesis for Program scope, GVL scope, nested
    UDT members, and array elements.

Docs:
  - docs/Driver.S7.Cli.md — address grammar cheat sheet + the PUT/GET-must-
    be-enabled gotcha every S7-1200/1500 operator hits.
  - docs/Driver.TwinCAT.Cli.md — AMS router prerequisite (XAR / standalone
    Router NuGet / remote AMS route) + per-command examples.

Wiring:
  - ZB.MOM.WW.OtOpcUa.slnx grew 4 entries (2 src + 2 tests).

Full-solution build clean. Both --help outputs verified end-to-end.

Driver CLI suite complete: 5 CLIs (otopcua-{modbus,abcip,ablegacy,s7,twincat}-cli)
sharing a common base + formatter. 122 CLI tests cumulative. Every driver family
shipped in v2 now has a shell-level ad-hoc validation tool.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 08:44:53 -04:00
Joseph Doherty
b2065f8730 Task #250 — AB CIP + AB Legacy test-client CLIs
Second + third of the four driver test clients. Both follow the same shape as
otopcua-modbus-cli (#249) and consume Driver.Cli.Common for DriverCommandBase +
SnapshotFormatter.

New projects:
  - src/ZB.MOM.WW.OtOpcUa.Driver.AbCip.Cli/ — otopcua-abcip-cli.
    AbCipCommandBase carries gateway (ab://host[:port]/cip-path) + family
    (ControlLogix/CompactLogix/Micro800/GuardLogix) + timeout.
    Commands: probe, read, write, subscribe.
    Value parser covers every AbCipDataType atomic type (Bool, SInt..LInt,
    USInt..ULInt, Real, LReal, String, Dt); Structure writes refused as
    out-of-scope for the CLI.
  - src/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Cli/ — otopcua-ablegacy-cli.
    AbLegacyCommandBase carries gateway + plc-type (Slc500/MicroLogix/Plc5/
    LogixPccc) + timeout.
    Commands: probe (default address N7:0), read, write, subscribe.
    Value parser covers Bit, Int, Long, Float, AnalogInt, String, and the
    three sub-element types (TimerElement / CounterElement / ControlElement
    all land on int32 at the wire).

Tests (35 new, 73 cumulative across the driver CLI family):
  - AB CIP: 17 tests — ParseValue happy-paths for every Logix atomic type,
    failure cases (non-numeric / bool garbage), tag-name synthesis.
  - AB Legacy: 18 tests — ParseValue coverage (Bit / Int / AnalogInt / Long /
    Float / String / sub-elements), PCCC address round-trip in tag names
    including bit-within-word + sub-element syntax.

Docs:
  - docs/Driver.AbCip.Cli.md — family ↔ CIP-path cheat sheet + examples per
    command + typical workflows.
  - docs/Driver.AbLegacy.Cli.md — PCCC address primer (file letters → CLI
    --type) + known ab_server upstream gap cross-ref to #224 close-out.

Wiring:
  - ZB.MOM.WW.OtOpcUa.slnx grew 4 entries (2 src + 2 tests).

Full-solution build clean. `otopcua-abcip-cli --help` + `otopcua-ablegacy-cli
--help` verified end-to-end.

Next up (#251): S7 + TwinCAT CLIs, same pattern.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 08:32:43 -04:00
Joseph Doherty
5dac2e9375 Task #249 — Driver test-client CLIs: shared lib + Modbus CLI first
Mirrors the v1 otopcua-cli value prop (ad-hoc shell-level PLC validation) for
the Modbus-TCP driver, and lays down the shared scaffolding that AB CIP, AB
Legacy, S7, and TwinCAT CLIs will build on.

New projects:
  - src/ZB.MOM.WW.OtOpcUa.Driver.Cli.Common/ — DriverCommandBase (verbose
    flag + Serilog config) + SnapshotFormatter (single-tag + table +
    write-result renders with invariant-culture value formatting + OPC UA
    status-code shortnames + UTC-normalised timestamps).
  - src/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Cli/ — otopcua-modbus-cli executable.
    Commands: probe, read, write, subscribe. ModbusCommandBase carries the
    host/port/unit-id flags + builds ModbusDriverOptions with Probe.Enabled
    =false (CLI runs are one-shot; driver-internal keep-alive would race).

Commands + coverage:
  - probe              single FC03 + GetHealth() + pretty-print
  - read               region × address × type synth into one driver tag
  - write              same shape + --value parsed per --type
  - subscribe          polled-subscription stream until Ctrl+C

Tests (38 total):
  - 16 SnapshotFormatterTests covering: status-code shortnames, unknown
    codes fall back to hex, null value + timestamp placeholders, bool
    lowercase, float invariant culture, string quoting, write-result shape,
    aligned table columns, mismatched-length rejection, UTC normalisation.
  - 22 Modbus CLI tests:
      · ReadCommandTests.SynthesiseTagName (5 theory cases)
      · WriteCommandParseValueTests (17 cases: bool aliases, unknown rejected,
        Int16 bounds, UInt16/Bcd16 type, Float32/64 invariant culture,
        String passthrough, BitInRegister, Int32 MinValue, non-numeric reject)

Wiring:
  - ZB.MOM.WW.OtOpcUa.slnx grew 4 entries (2 src + 2 tests).
  - docs/Driver.Modbus.Cli.md — operator-facing runbook with examples per
    command + output format + typical workflows.

Regression: full-solution build clean; shared-lib tests 16/0, Modbus CLI tests
22/0.

Next up: repeat the pattern for AB CIP (shares ~40% more with Modbus via
libplctag), then AB Legacy, S7, TwinCAT. The shared base stays as-is unless
one of those exposes a gap the Modbus-first pass missed.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 08:15:14 -04:00
Joseph Doherty
dfe3731c73 Task #220 — Wire FOCAS into DriverFactoryRegistry bootstrap pipeline
Closes the non-hardware gap surfaced in the #220 audit: FOCAS had full Tier-C
architecture (Driver.FOCAS + Driver.FOCAS.Host + Driver.FOCAS.Shared, supervisor,
post-mortem MMF, NSSM scripts, 239 tests) but no factory registration, so config-DB
DriverInstance rows of type "FOCAS" would fail at bootstrap with "unknown driver
type". Hardware-gated FwlibHostedBackend (real Fwlib32 P/Invoke inside the Host
process) stays deferred under #222 lab-rig.

Ships:
  - FocasDriverFactoryExtensions.Register(registry) mirroring the Galaxy pattern.
    JSON schema selects backend via "Backend" field:
      "ipc" (default) — IpcFocasClientFactory → named-pipe FocasIpcClient →
                        Driver.FOCAS.Host process (Tier-C isolation)
      "fwlib"         — direct in-process FwlibFocasClientFactory (P/Invoke)
      "unimplemented" — UnimplementedFocasClientFactory (fail-fast on use —
                        useful for staging DriverInstance rows pre-Host-deploy)
  - Devices / Tags / Probe / Timeout / Series feed into FocasDriverOptions.
    Series validated eagerly at top-level so typos fail at bootstrap, not first
    read. Tag DataType + Series enum values surface clear errors listing valid
    options.
  - Program.cs adds FocasDriverFactoryExtensions.Register alongside Galaxy.
  - Driver.FOCAS.csproj references Core (for DriverFactoryRegistry).
  - Server.csproj adds Driver.FOCAS ProjectReference so the factory type is
    reachable from Program.cs.

Tests: 13 new FocasDriverFactoryExtensionsTests covering: registry entry,
case-insensitive lookup, ipc backend with full config, ipc defaults, missing
PipeName/SharedSecret errors, fwlib backend short-path, unimplemented backend,
unknown-backend error, unknown-Series error, tag missing DataType, null/ws args,
duplicate-register throws.

Regression: 202 FOCAS + 13 FOCAS.Host + 24 FOCAS.Shared + 239 Server all pass.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 01:08:25 -04:00
Joseph Doherty
8221fac8c1 Task #219 follow-up — close AlarmConditionState child-NodeId + event-propagation gaps
PR #197 surfaced two integration-level wiring gaps in DriverNodeManager's
MarkAsAlarmCondition path; this commit fixes both and upgrades the integration
test to assert them end-to-end.

Fix 1 — addressable child nodes: AlarmConditionState inherits ~50 typed children
(Severity / Message / ActiveState / AckedState / EnabledState / …). The stack
was leaving them with Foundation-namespace NodeIds (type-declaration defaults) or
shared ns=0 counter allocations, so client Read on a child returned
BadNodeIdUnknown. Pass assignNodeIds=true to alarm.Create, then walk the condition
subtree and rewrite each descendant's NodeId symbolically as
  {condition-full-ref}.{symbolic-path}
in the node manager's namespace. Stable, unique, and collision-free across
multiple alarm instances in the same driver.

Fix 2 — event propagation to Server.EventNotifier: OPC UA Part 9 event
propagation relies on the alarm condition being reachable from Objects/Server
via HasNotifier. Call CustomNodeManager2.AddRootNotifier(alarm) after registering
the condition so subscriptions placed on Server-object EventNotifier receive the
ReportEvent calls ConditionSink emits per-transition.

Test upgrades in AlarmSubscribeIntegrationTests:
  - Driver_alarm_transition_updates_server_side_AlarmConditionState_node — now
    asserts Severity == 700, Message text, and ActiveState.Id == true through
    the OPC UA client (previously scoped out as BadNodeIdUnknown).
  - New: Driver_alarm_event_flows_to_client_subscription_on_Server_EventNotifier
    subscribes an OPC UA event monitor on ObjectIds.Server, fires a driver
    transition, and waits for the AlarmConditionType event to be delivered,
    asserting Message + Severity fields. Previously scoped out as "Part 9 event
    propagation out of reach."

Regression checks: 239 server tests pass (+1 new event-subscription test),
195 Core tests pass.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 00:22:02 -04:00