Joseph Doherty 97fcf624ae fix(drivers): mid-connect ApplyDelta adopts config in Calculation, refuses it in Galaxy (#664)
AdoptConfigDuringInit re-runs InitializeAsync(newConfig) and acks success, but
Calculation and Galaxy ignored the JSON there: Calculation kept its old tag
set, and Galaxy connected on its old endpoint. Calculation now rebuilds its tag
table from a config with a body (sharing AdoptConfig with ReinitializeAsync and
stopping any running timer scheduler first). Galaxy, which cannot hot-swap its
options, refuses a non-equivalent one the way ReinitializeAsync does. The actor
now sends DeltaApplied once the adopted init succeeds, so a dependency
consumer's mux interest is re-registered. Unreachable from deploys since #516.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-09 11:05:58 -04:00
..