@@ -13,22 +13,30 @@ confirmed DL205 quirk lands in a follow-up PR as a named test in that project.
|
||||
|
||||
## Harness
|
||||
|
||||
**Chosen simulator: ModbusPal** (Java, scriptable). Rationale:
|
||||
- Scriptable enough to mimic device-specific behaviors (non-standard register
|
||||
layouts, custom exception codes, intentional response delays).
|
||||
- Runs locally, no CI dependency. Tests skip when `localhost:502` (or the configured
|
||||
simulator endpoint) isn't reachable.
|
||||
- Free + long-maintained — physical PLC bench is unavailable in most dev
|
||||
environments, and renting cloud PLCs isn't worth the per-test cost.
|
||||
**Chosen simulator: pymodbus 3.13.0** (`pip install 'pymodbus[simulator]==3.13.0'`).
|
||||
Replaced ModbusPal in PR 43 — see `tests/.../Pymodbus/README.md` for the
|
||||
trade-off rationale. Headline reasons:
|
||||
|
||||
**Setup pattern** (not yet codified in a script — will land alongside the integration
|
||||
test project):
|
||||
1. Install ModbusPal, load the per-device `.xmpp` profile from
|
||||
`tests/Driver.Modbus.IntegrationTests/ModbusPal/` (TBD directory).
|
||||
2. Start the simulator listening on `localhost:502` (or override via
|
||||
`MODBUS_SIM_ENDPOINT` env var).
|
||||
3. `dotnet test` the integration project — tests auto-skip when the endpoint is
|
||||
unreachable, so forgetting to start the simulator doesn't wedge CI.
|
||||
- **Headless** pure-Python CLI; no Java GUI, runs cleanly on a CI runner.
|
||||
- **Maintained** — current stable 3.13.0; ModbusPal 1.6b is abandoned.
|
||||
- **All four standard tables** (HR, IR, coils, DI) configurable; ModbusPal
|
||||
1.6b only exposed HR + coils.
|
||||
- **Built-in actions** (`increment`, `random`, `timestamp`, `uptime`) +
|
||||
optional custom-Python actions for declarative dynamic behaviors.
|
||||
- **Per-register raw uint16 seeding** — encoding the DL205 string-byte-order
|
||||
/ BCD / CDAB-float quirks stays explicit (the quirk math lives in the
|
||||
`_quirk` JSON-comment fields next to each register).
|
||||
- Pip-installable on Windows; sidesteps the privileged-port admin
|
||||
requirement by defaulting to TCP **5020** instead of 502.
|
||||
|
||||
**Setup pattern**:
|
||||
1. `pip install "pymodbus[simulator]==3.13.0"`.
|
||||
2. Start the simulator with one of the in-repo profiles:
|
||||
`tests\.../Pymodbus\serve.ps1 -Profile standard` (or `-Profile dl205`).
|
||||
3. `dotnet test tests\ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests` —
|
||||
tests auto-skip when the endpoint is unreachable. Default endpoint is
|
||||
`localhost:5020`; override via `MODBUS_SIM_ENDPOINT` for a real PLC on its
|
||||
native port 502.
|
||||
|
||||
## Per-device quirk catalog
|
||||
|
||||
@@ -87,20 +95,27 @@ vendors get promoted into driver defaults or opt-in options:
|
||||
protocol end-to-end. The in-memory `FakeTransport` from the unit test suite is
|
||||
deliberately not used here — its value is speed + determinism, which doesn't
|
||||
help reproduce device-specific issues.
|
||||
- **Don't depend on ModbusPal state between tests.** Each test resets the
|
||||
- **Don't depend on simulator state between tests.** Each test resets the
|
||||
simulator's register bank or uses a unique address range. Avoid relying on
|
||||
"previous test left value at register 10" setups that flake when tests run in
|
||||
parallel or re-order.
|
||||
parallel or re-order. Either the test mutates the scratch ranges and restores
|
||||
on finally, or it uses pymodbus's REST API to reset state between facts.
|
||||
|
||||
## Next concrete PRs
|
||||
|
||||
- **PR 30 — Integration test project + DL205 profile scaffold** — **DONE**.
|
||||
Shipped `tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests` with
|
||||
`ModbusSimulatorFixture` (TCP-probe, skips with a clear `SkipReason` when the
|
||||
endpoint is unreachable), `DL205/DL205Profile.cs` (tag map stub — one
|
||||
writable holding register at address 100), and `DL205/DL205SmokeTests.cs`
|
||||
(write-then-read round-trip). `ModbusPal/` directory holds the README
|
||||
pointing at the to-be-committed `DL205.xmpp` profile.
|
||||
- **PR 31+**: one PR per confirmed DL205 quirk, landing the named test + any
|
||||
driver-side adjustment (e.g., retry on dropped TxId) needed to pass it. Drop
|
||||
the `DL205.xmpp` profile into `ModbusPal/` alongside the first quirk PR.
|
||||
endpoint is unreachable), `DL205/DL205Profile.cs` (tag map stub), and
|
||||
`DL205/DL205SmokeTests.cs` (write-then-read round-trip).
|
||||
- **PR 41 — DL205 quirk catalog doc** — **DONE**. `docs/v2/dl205.md`
|
||||
documents every DL205/DL260 Modbus divergence with primary-source citations.
|
||||
- **PR 42 — ModbusPal `.xmpp` profiles** — **SUPERSEDED by PR 43**. Replaced
|
||||
with pymodbus JSON because ModbusPal 1.6b is abandoned, GUI-only, and only
|
||||
exposes 2 of the 4 standard tables.
|
||||
- **PR 43 — pymodbus JSON profiles** — **DONE**. `Pymodbus/standard.json` +
|
||||
`Pymodbus/dl205.json` + `Pymodbus/serve.ps1` runner. Both bind TCP 5020.
|
||||
- **PR 44+**: one PR per confirmed DL205 quirk, landing the named test + any
|
||||
driver-side adjustment (string byte order, BCD decoder, V-memory address
|
||||
helper, FC16 cap-per-device-family) needed to pass it. Each quirk's value
|
||||
is already pre-encoded in `Pymodbus/dl205.json`.
|
||||
|
||||
165
src/ZB.MOM.WW.OtOpcUa.Driver.Modbus/DirectLogicAddress.cs
Normal file
165
src/ZB.MOM.WW.OtOpcUa.Driver.Modbus/DirectLogicAddress.cs
Normal file
@@ -0,0 +1,165 @@
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus;
|
||||
|
||||
/// <summary>
|
||||
/// AutomationDirect DirectLOGIC address-translation helpers. DL205 / DL260 / DL350 CPUs
|
||||
/// address V-memory in OCTAL while the Modbus wire uses DECIMAL PDU addresses — operators
|
||||
/// see "V2000" in the PLC ladder-logic editor but the Modbus client must write PDU 0x0400.
|
||||
/// The formulas differ between user V-memory (simple octal-to-decimal) and system V-memory
|
||||
/// (fixed bank mappings), so the two cases are separate methods rather than one overloaded
|
||||
/// "ToPdu" call.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// See <c>docs/v2/dl205.md</c> §V-memory for the full CPU-family matrix + rationale.
|
||||
/// References: D2-USER-M appendix (DL205/D2-260), H2-ECOM-M §6.5 (absolute vs relative
|
||||
/// addressing), AutomationDirect forum guidance on V40400 system-base.
|
||||
/// </remarks>
|
||||
public static class DirectLogicAddress
|
||||
{
|
||||
/// <summary>
|
||||
/// Convert a DirectLOGIC user V-memory address (octal) to a 0-based Modbus PDU address.
|
||||
/// Accepts bare octal (<c>"2000"</c>) or <c>V</c>-prefixed (<c>"V2000"</c>). Range
|
||||
/// depends on CPU model — DL205 D2-260 user memory is V1400-V7377 + V10000-V17777
|
||||
/// octal, DL260 extends to V77777 octal.
|
||||
/// </summary>
|
||||
/// <exception cref="ArgumentException">Input is null / empty / contains non-octal digits (8,9).</exception>
|
||||
/// <exception cref="OverflowException">Parsed value exceeds ushort.MaxValue (0xFFFF).</exception>
|
||||
public static ushort UserVMemoryToPdu(string vAddress)
|
||||
{
|
||||
if (string.IsNullOrWhiteSpace(vAddress))
|
||||
throw new ArgumentException("V-memory address must not be empty", nameof(vAddress));
|
||||
var s = vAddress.Trim();
|
||||
if (s[0] == 'V' || s[0] == 'v') s = s.Substring(1);
|
||||
if (s.Length == 0)
|
||||
throw new ArgumentException($"V-memory address '{vAddress}' has no digits", nameof(vAddress));
|
||||
|
||||
// Octal conversion. Reject 8/9 digits up-front — int.Parse in the obvious base would
|
||||
// accept them silently because .NET has no built-in base-8 parser.
|
||||
uint result = 0;
|
||||
foreach (var ch in s)
|
||||
{
|
||||
if (ch < '0' || ch > '7')
|
||||
throw new ArgumentException(
|
||||
$"V-memory address '{vAddress}' contains non-octal digit '{ch}' — DirectLOGIC V-addresses are octal (0-7)",
|
||||
nameof(vAddress));
|
||||
result = result * 8 + (uint)(ch - '0');
|
||||
if (result > ushort.MaxValue)
|
||||
throw new OverflowException(
|
||||
$"V-memory address '{vAddress}' exceeds the 16-bit Modbus PDU address range");
|
||||
}
|
||||
return (ushort)result;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// DirectLOGIC system V-memory starts at octal V40400 on DL260 / H2-ECOM100 in factory
|
||||
/// "absolute" addressing mode. Unlike user V-memory, the mapping is NOT a simple
|
||||
/// octal-to-decimal conversion — the CPU relocates the system bank to Modbus PDU 0x2100
|
||||
/// (decimal 8448). This helper returns the CPU-family base plus a user-supplied offset
|
||||
/// within the system bank.
|
||||
/// </summary>
|
||||
public const ushort SystemVMemoryBasePdu = 0x2100;
|
||||
|
||||
/// <param name="offsetWithinSystemBank">
|
||||
/// 0-based register offset within the system bank. Pass 0 for V40400 itself; pass 1 for
|
||||
/// V40401 (octal), and so on. NOT an octal-decoded value — the system bank lives at
|
||||
/// consecutive PDU addresses, so the offset is plain decimal.
|
||||
/// </param>
|
||||
public static ushort SystemVMemoryToPdu(ushort offsetWithinSystemBank)
|
||||
{
|
||||
var pdu = SystemVMemoryBasePdu + offsetWithinSystemBank;
|
||||
if (pdu > ushort.MaxValue)
|
||||
throw new OverflowException(
|
||||
$"System V-memory offset {offsetWithinSystemBank} maps past 0xFFFF");
|
||||
return (ushort)pdu;
|
||||
}
|
||||
|
||||
// Bit-memory bases per DL260 user manual §I/O-configuration.
|
||||
// Numbers after X / Y / C / SP are OCTAL in DirectLOGIC notation. The Modbus base is
|
||||
// added to the octal-decoded offset; e.g. Y017 = Modbus coil 2048 + octal(17) = 2048 + 15 = 2063.
|
||||
|
||||
/// <summary>
|
||||
/// DL260 Y-output coil base. Y0 octal → Modbus coil address 2048 (0-based).
|
||||
/// </summary>
|
||||
public const ushort YOutputBaseCoil = 2048;
|
||||
|
||||
/// <summary>
|
||||
/// DL260 C-relay coil base. C0 octal → Modbus coil address 3072 (0-based).
|
||||
/// </summary>
|
||||
public const ushort CRelayBaseCoil = 3072;
|
||||
|
||||
/// <summary>
|
||||
/// DL260 X-input discrete-input base. X0 octal → Modbus discrete input 0.
|
||||
/// </summary>
|
||||
public const ushort XInputBaseDiscrete = 0;
|
||||
|
||||
/// <summary>
|
||||
/// DL260 SP special-relay discrete-input base. SP0 octal → Modbus discrete input 1024.
|
||||
/// Read-only; writing SP relays is rejected with Illegal Data Address.
|
||||
/// </summary>
|
||||
public const ushort SpecialBaseDiscrete = 1024;
|
||||
|
||||
/// <summary>
|
||||
/// Translate a DirectLOGIC Y-output address (e.g. <c>"Y0"</c>, <c>"Y17"</c>) to its
|
||||
/// 0-based Modbus coil address on DL260. The trailing number is OCTAL, matching the
|
||||
/// ladder-logic editor's notation.
|
||||
/// </summary>
|
||||
public static ushort YOutputToCoil(string yAddress) =>
|
||||
AddOctalOffset(YOutputBaseCoil, StripPrefix(yAddress, 'Y'));
|
||||
|
||||
/// <summary>
|
||||
/// Translate a DirectLOGIC C-relay address (e.g. <c>"C0"</c>, <c>"C1777"</c>) to its
|
||||
/// 0-based Modbus coil address.
|
||||
/// </summary>
|
||||
public static ushort CRelayToCoil(string cAddress) =>
|
||||
AddOctalOffset(CRelayBaseCoil, StripPrefix(cAddress, 'C'));
|
||||
|
||||
/// <summary>
|
||||
/// Translate a DirectLOGIC X-input address (e.g. <c>"X0"</c>, <c>"X17"</c>) to its
|
||||
/// 0-based Modbus discrete-input address. Reading an unpopulated X returns 0, not an
|
||||
/// exception — the CPU sizes the table to configured I/O, not installed modules.
|
||||
/// </summary>
|
||||
public static ushort XInputToDiscrete(string xAddress) =>
|
||||
AddOctalOffset(XInputBaseDiscrete, StripPrefix(xAddress, 'X'));
|
||||
|
||||
/// <summary>
|
||||
/// Translate a DirectLOGIC SP-special-relay address (e.g. <c>"SP0"</c>) to its 0-based
|
||||
/// Modbus discrete-input address. Accepts <c>"SP"</c> prefix case-insensitively.
|
||||
/// </summary>
|
||||
public static ushort SpecialToDiscrete(string spAddress)
|
||||
{
|
||||
if (string.IsNullOrWhiteSpace(spAddress))
|
||||
throw new ArgumentException("SP address must not be empty", nameof(spAddress));
|
||||
var s = spAddress.Trim();
|
||||
if (s.Length >= 2 && (s[0] == 'S' || s[0] == 's') && (s[1] == 'P' || s[1] == 'p'))
|
||||
s = s.Substring(2);
|
||||
return AddOctalOffset(SpecialBaseDiscrete, s);
|
||||
}
|
||||
|
||||
private static string StripPrefix(string address, char expectedPrefix)
|
||||
{
|
||||
if (string.IsNullOrWhiteSpace(address))
|
||||
throw new ArgumentException("Address must not be empty", nameof(address));
|
||||
var s = address.Trim();
|
||||
if (s.Length > 0 && char.ToUpperInvariant(s[0]) == char.ToUpperInvariant(expectedPrefix))
|
||||
s = s.Substring(1);
|
||||
return s;
|
||||
}
|
||||
|
||||
private static ushort AddOctalOffset(ushort baseAddr, string octalDigits)
|
||||
{
|
||||
if (octalDigits.Length == 0)
|
||||
throw new ArgumentException("Address has no digits", nameof(octalDigits));
|
||||
uint offset = 0;
|
||||
foreach (var ch in octalDigits)
|
||||
{
|
||||
if (ch < '0' || ch > '7')
|
||||
throw new ArgumentException(
|
||||
$"Address contains non-octal digit '{ch}' — DirectLOGIC I/O addresses are octal (0-7)",
|
||||
nameof(octalDigits));
|
||||
offset = offset * 8 + (uint)(ch - '0');
|
||||
}
|
||||
var result = baseAddr + offset;
|
||||
if (result > ushort.MaxValue)
|
||||
throw new OverflowException($"Address {baseAddr}+{offset} exceeds 0xFFFF");
|
||||
return (ushort)result;
|
||||
}
|
||||
}
|
||||
@@ -141,9 +141,16 @@ public sealed class ModbusDriver(ModbusDriverOptions options, string driverInsta
|
||||
results[i] = new DataValueSnapshot(value, 0u, now, now);
|
||||
_health = new DriverHealth(DriverState.Healthy, now, null);
|
||||
}
|
||||
catch (ModbusException mex)
|
||||
{
|
||||
results[i] = new DataValueSnapshot(null, MapModbusExceptionToStatus(mex.ExceptionCode), null, now);
|
||||
_health = new DriverHealth(DriverState.Degraded, _health.LastSuccessfulRead, mex.Message);
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
results[i] = new DataValueSnapshot(null, StatusBadInternalError, null, now);
|
||||
// Non-Modbus-layer failure: socket dropped, timeout, malformed response. Surface
|
||||
// as communication error so callers can distinguish it from tag-level faults.
|
||||
results[i] = new DataValueSnapshot(null, StatusBadCommunicationError, null, now);
|
||||
_health = new DriverHealth(DriverState.Degraded, _health.LastSuccessfulRead, ex.Message);
|
||||
}
|
||||
}
|
||||
@@ -171,11 +178,14 @@ public sealed class ModbusDriver(ModbusDriverOptions options, string driverInsta
|
||||
{
|
||||
var quantity = RegisterCount(tag);
|
||||
var fc = tag.Region == ModbusRegion.HoldingRegisters ? (byte)0x03 : (byte)0x04;
|
||||
var pdu = new byte[] { fc, (byte)(tag.Address >> 8), (byte)(tag.Address & 0xFF),
|
||||
(byte)(quantity >> 8), (byte)(quantity & 0xFF) };
|
||||
var resp = await transport.SendAsync(_options.UnitId, pdu, ct).ConfigureAwait(false);
|
||||
// resp = [fc][byte-count][data...]
|
||||
var data = new ReadOnlySpan<byte>(resp, 2, resp[1]);
|
||||
// Auto-chunk when the tag's register span exceeds the caller-configured cap.
|
||||
// Affects long strings (FC03/04 > 125 regs is spec-forbidden; DL205 caps at 128,
|
||||
// Mitsubishi Q caps at 64). Non-string tags max out at 4 regs so the cap never
|
||||
// triggers for numerics.
|
||||
var cap = _options.MaxRegistersPerRead == 0 ? (ushort)125 : _options.MaxRegistersPerRead;
|
||||
var data = quantity <= cap
|
||||
? await ReadRegisterBlockAsync(transport, fc, tag.Address, quantity, ct).ConfigureAwait(false)
|
||||
: await ReadRegisterBlockChunkedAsync(transport, fc, tag.Address, quantity, cap, ct).ConfigureAwait(false);
|
||||
return DecodeRegister(data, tag);
|
||||
}
|
||||
default:
|
||||
@@ -183,6 +193,33 @@ public sealed class ModbusDriver(ModbusDriverOptions options, string driverInsta
|
||||
}
|
||||
}
|
||||
|
||||
private async Task<byte[]> ReadRegisterBlockAsync(
|
||||
IModbusTransport transport, byte fc, ushort address, ushort quantity, CancellationToken ct)
|
||||
{
|
||||
var pdu = new byte[] { fc, (byte)(address >> 8), (byte)(address & 0xFF),
|
||||
(byte)(quantity >> 8), (byte)(quantity & 0xFF) };
|
||||
var resp = await transport.SendAsync(_options.UnitId, pdu, ct).ConfigureAwait(false);
|
||||
// resp = [fc][byte-count][data...]
|
||||
var data = new byte[resp[1]];
|
||||
Buffer.BlockCopy(resp, 2, data, 0, resp[1]);
|
||||
return data;
|
||||
}
|
||||
|
||||
private async Task<byte[]> ReadRegisterBlockChunkedAsync(
|
||||
IModbusTransport transport, byte fc, ushort address, ushort totalRegs, ushort cap, CancellationToken ct)
|
||||
{
|
||||
var assembled = new byte[totalRegs * 2];
|
||||
ushort done = 0;
|
||||
while (done < totalRegs)
|
||||
{
|
||||
var chunk = (ushort)Math.Min(cap, totalRegs - done);
|
||||
var chunkBytes = await ReadRegisterBlockAsync(transport, fc, (ushort)(address + done), chunk, ct).ConfigureAwait(false);
|
||||
Buffer.BlockCopy(chunkBytes, 0, assembled, done * 2, chunkBytes.Length);
|
||||
done += chunk;
|
||||
}
|
||||
return assembled;
|
||||
}
|
||||
|
||||
// ---- IWritable ----
|
||||
|
||||
public async Task<IReadOnlyList<WriteResult>> WriteAsync(
|
||||
@@ -208,6 +245,10 @@ public sealed class ModbusDriver(ModbusDriverOptions options, string driverInsta
|
||||
await WriteOneAsync(transport, tag, w.Value, cancellationToken).ConfigureAwait(false);
|
||||
results[i] = new WriteResult(0u);
|
||||
}
|
||||
catch (ModbusException mex)
|
||||
{
|
||||
results[i] = new WriteResult(MapModbusExceptionToStatus(mex.ExceptionCode));
|
||||
}
|
||||
catch (Exception)
|
||||
{
|
||||
results[i] = new WriteResult(StatusBadInternalError);
|
||||
@@ -239,8 +280,13 @@ public sealed class ModbusDriver(ModbusDriverOptions options, string driverInsta
|
||||
}
|
||||
else
|
||||
{
|
||||
// FC 16 (Write Multiple Registers) for 32-bit types
|
||||
// FC 16 (Write Multiple Registers) for 32-bit types.
|
||||
var qty = (ushort)(bytes.Length / 2);
|
||||
var writeCap = _options.MaxRegistersPerWrite == 0 ? (ushort)123 : _options.MaxRegistersPerWrite;
|
||||
if (qty > writeCap)
|
||||
throw new InvalidOperationException(
|
||||
$"Write of {qty} registers to {tag.Name} exceeds MaxRegistersPerWrite={writeCap}. " +
|
||||
$"Split the tag (e.g. shorter StringLength) — partial FC16 chunks would lose atomicity.");
|
||||
var pdu = new byte[6 + 1 + bytes.Length];
|
||||
pdu[0] = 0x10;
|
||||
pdu[1] = (byte)(tag.Address >> 8); pdu[2] = (byte)(tag.Address & 0xFF);
|
||||
@@ -404,8 +450,8 @@ public sealed class ModbusDriver(ModbusDriverOptions options, string driverInsta
|
||||
/// </summary>
|
||||
internal static ushort RegisterCount(ModbusTagDefinition tag) => tag.DataType switch
|
||||
{
|
||||
ModbusDataType.Int16 or ModbusDataType.UInt16 or ModbusDataType.BitInRegister => 1,
|
||||
ModbusDataType.Int32 or ModbusDataType.UInt32 or ModbusDataType.Float32 => 2,
|
||||
ModbusDataType.Int16 or ModbusDataType.UInt16 or ModbusDataType.BitInRegister or ModbusDataType.Bcd16 => 1,
|
||||
ModbusDataType.Int32 or ModbusDataType.UInt32 or ModbusDataType.Float32 or ModbusDataType.Bcd32 => 2,
|
||||
ModbusDataType.Int64 or ModbusDataType.UInt64 or ModbusDataType.Float64 => 4,
|
||||
ModbusDataType.String => (ushort)((tag.StringLength + 1) / 2), // 2 chars per register
|
||||
_ => throw new InvalidOperationException($"Non-register data type {tag.DataType}"),
|
||||
@@ -435,6 +481,17 @@ public sealed class ModbusDriver(ModbusDriverOptions options, string driverInsta
|
||||
{
|
||||
case ModbusDataType.Int16: return BinaryPrimitives.ReadInt16BigEndian(data);
|
||||
case ModbusDataType.UInt16: return BinaryPrimitives.ReadUInt16BigEndian(data);
|
||||
case ModbusDataType.Bcd16:
|
||||
{
|
||||
var raw = BinaryPrimitives.ReadUInt16BigEndian(data);
|
||||
return (int)DecodeBcd(raw, nibbles: 4);
|
||||
}
|
||||
case ModbusDataType.Bcd32:
|
||||
{
|
||||
var b = NormalizeWordOrder(data, tag.ByteOrder);
|
||||
var raw = BinaryPrimitives.ReadUInt32BigEndian(b);
|
||||
return (int)DecodeBcd(raw, nibbles: 8);
|
||||
}
|
||||
case ModbusDataType.BitInRegister:
|
||||
{
|
||||
var raw = BinaryPrimitives.ReadUInt16BigEndian(data);
|
||||
@@ -472,13 +529,21 @@ public sealed class ModbusDriver(ModbusDriverOptions options, string driverInsta
|
||||
}
|
||||
case ModbusDataType.String:
|
||||
{
|
||||
// ASCII, 2 chars per register, packed high byte = first char.
|
||||
// Respect the caller's StringLength (truncate nul-padded regions).
|
||||
// ASCII, 2 chars per register. HighByteFirst (standard) packs the first char in
|
||||
// the high byte of each register; LowByteFirst (DL205/DL260) packs the first char
|
||||
// in the low byte. Respect StringLength (truncate nul-padded regions).
|
||||
var chars = new char[tag.StringLength];
|
||||
for (var i = 0; i < tag.StringLength; i++)
|
||||
{
|
||||
var b = data[i];
|
||||
if (b == 0) { return new string(chars, 0, i); }
|
||||
var regIdx = i / 2;
|
||||
var highByte = data[regIdx * 2];
|
||||
var lowByte = data[regIdx * 2 + 1];
|
||||
byte b;
|
||||
if (tag.StringByteOrder == ModbusStringByteOrder.HighByteFirst)
|
||||
b = (i % 2 == 0) ? highByte : lowByte;
|
||||
else
|
||||
b = (i % 2 == 0) ? lowByte : highByte;
|
||||
if (b == 0) return new string(chars, 0, i);
|
||||
chars[i] = (char)b;
|
||||
}
|
||||
return new string(chars);
|
||||
@@ -502,6 +567,21 @@ public sealed class ModbusDriver(ModbusDriverOptions options, string driverInsta
|
||||
var v = Convert.ToUInt16(value);
|
||||
var b = new byte[2]; BinaryPrimitives.WriteUInt16BigEndian(b, v); return b;
|
||||
}
|
||||
case ModbusDataType.Bcd16:
|
||||
{
|
||||
var v = Convert.ToUInt32(value);
|
||||
if (v > 9999) throw new OverflowException($"BCD16 value {v} exceeds 4 decimal digits");
|
||||
var raw = (ushort)EncodeBcd(v, nibbles: 4);
|
||||
var b = new byte[2]; BinaryPrimitives.WriteUInt16BigEndian(b, raw); return b;
|
||||
}
|
||||
case ModbusDataType.Bcd32:
|
||||
{
|
||||
var v = Convert.ToUInt32(value);
|
||||
if (v > 99_999_999u) throw new OverflowException($"BCD32 value {v} exceeds 8 decimal digits");
|
||||
var raw = EncodeBcd(v, nibbles: 8);
|
||||
var b = new byte[4]; BinaryPrimitives.WriteUInt32BigEndian(b, raw);
|
||||
return NormalizeWordOrder(b, tag.ByteOrder);
|
||||
}
|
||||
case ModbusDataType.Int32:
|
||||
{
|
||||
var v = Convert.ToInt32(value);
|
||||
@@ -543,7 +623,14 @@ public sealed class ModbusDriver(ModbusDriverOptions options, string driverInsta
|
||||
var s = Convert.ToString(value) ?? string.Empty;
|
||||
var regs = (tag.StringLength + 1) / 2;
|
||||
var b = new byte[regs * 2];
|
||||
for (var i = 0; i < tag.StringLength && i < s.Length; i++) b[i] = (byte)s[i];
|
||||
for (var i = 0; i < tag.StringLength && i < s.Length; i++)
|
||||
{
|
||||
var regIdx = i / 2;
|
||||
var destIdx = tag.StringByteOrder == ModbusStringByteOrder.HighByteFirst
|
||||
? (i % 2 == 0 ? regIdx * 2 : regIdx * 2 + 1)
|
||||
: (i % 2 == 0 ? regIdx * 2 + 1 : regIdx * 2);
|
||||
b[destIdx] = (byte)s[i];
|
||||
}
|
||||
// remaining bytes stay 0 — nul-padded per PLC convention
|
||||
return b;
|
||||
}
|
||||
@@ -564,15 +651,77 @@ public sealed class ModbusDriver(ModbusDriverOptions options, string driverInsta
|
||||
ModbusDataType.Float32 => DriverDataType.Float32,
|
||||
ModbusDataType.Float64 => DriverDataType.Float64,
|
||||
ModbusDataType.String => DriverDataType.String,
|
||||
ModbusDataType.Bcd16 or ModbusDataType.Bcd32 => DriverDataType.Int32,
|
||||
_ => DriverDataType.Int32,
|
||||
};
|
||||
|
||||
/// <summary>
|
||||
/// Decode an N-nibble binary-coded-decimal value. Each nibble of <paramref name="raw"/>
|
||||
/// encodes one decimal digit (most-significant nibble first). Rejects nibbles > 9 —
|
||||
/// the hardware sometimes produces garbage during transitions and silent non-BCD reads
|
||||
/// would quietly corrupt the caller's data.
|
||||
/// </summary>
|
||||
internal static uint DecodeBcd(uint raw, int nibbles)
|
||||
{
|
||||
uint result = 0;
|
||||
for (var i = nibbles - 1; i >= 0; i--)
|
||||
{
|
||||
var digit = (raw >> (i * 4)) & 0xF;
|
||||
if (digit > 9)
|
||||
throw new InvalidDataException(
|
||||
$"Non-BCD nibble 0x{digit:X} at position {i} of raw=0x{raw:X}");
|
||||
result = result * 10 + digit;
|
||||
}
|
||||
return result;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Encode a decimal value as N-nibble BCD. Caller is responsible for range-checking
|
||||
/// against the nibble capacity (10^nibbles - 1).
|
||||
/// </summary>
|
||||
internal static uint EncodeBcd(uint value, int nibbles)
|
||||
{
|
||||
uint result = 0;
|
||||
for (var i = 0; i < nibbles; i++)
|
||||
{
|
||||
var digit = value % 10;
|
||||
result |= digit << (i * 4);
|
||||
value /= 10;
|
||||
}
|
||||
return result;
|
||||
}
|
||||
|
||||
private IModbusTransport RequireTransport() =>
|
||||
_transport ?? throw new InvalidOperationException("ModbusDriver not initialized");
|
||||
|
||||
private const uint StatusBadInternalError = 0x80020000u;
|
||||
private const uint StatusBadNodeIdUnknown = 0x80340000u;
|
||||
private const uint StatusBadNotWritable = 0x803B0000u;
|
||||
private const uint StatusBadOutOfRange = 0x803C0000u;
|
||||
private const uint StatusBadNotSupported = 0x803D0000u;
|
||||
private const uint StatusBadDeviceFailure = 0x80550000u;
|
||||
private const uint StatusBadCommunicationError = 0x80050000u;
|
||||
|
||||
/// <summary>
|
||||
/// Map a server-returned Modbus exception code to the most informative OPC UA
|
||||
/// StatusCode. Keeps the driver's outward-facing status surface aligned with what a
|
||||
/// Modbus engineer would expect when reading the spec: exception 02 (Illegal Data
|
||||
/// Address) surfaces as BadOutOfRange so clients can distinguish "tag wrong" from
|
||||
/// generic BadInternalError, exception 04 (Server Failure) as BadDeviceFailure so
|
||||
/// operators see a CPU-mode problem rather than a driver bug, etc. Per
|
||||
/// <c>docs/v2/dl205.md</c>, DL205/DL260 returns only codes 01-04 — no proprietary
|
||||
/// extensions.
|
||||
/// </summary>
|
||||
internal static uint MapModbusExceptionToStatus(byte exceptionCode) => exceptionCode switch
|
||||
{
|
||||
0x01 => StatusBadNotSupported, // Illegal Function — FC not in supported list
|
||||
0x02 => StatusBadOutOfRange, // Illegal Data Address — register outside mapped range
|
||||
0x03 => StatusBadOutOfRange, // Illegal Data Value — quantity over per-FC cap
|
||||
0x04 => StatusBadDeviceFailure, // Server Failure — CPU in PROGRAM mode during protected write
|
||||
0x05 or 0x06 => StatusBadDeviceFailure, // Acknowledge / Server Busy — long-running op / busy
|
||||
0x0A or 0x0B => StatusBadCommunicationError, // Gateway path unavailable / target failed to respond
|
||||
_ => StatusBadInternalError,
|
||||
};
|
||||
|
||||
public void Dispose() => DisposeAsync().AsTask().GetAwaiter().GetResult();
|
||||
public async ValueTask DisposeAsync()
|
||||
|
||||
@@ -25,6 +25,26 @@ public sealed class ModbusDriverOptions
|
||||
/// <see cref="IHostConnectivityProbe"/>.
|
||||
/// </summary>
|
||||
public ModbusProbeOptions Probe { get; init; } = new();
|
||||
|
||||
/// <summary>
|
||||
/// Maximum registers per FC03 (Read Holding Registers) / FC04 (Read Input Registers)
|
||||
/// transaction. Modbus-TCP spec allows 125; many device families impose lower caps:
|
||||
/// AutomationDirect DL205/DL260 cap at <c>128</c>, Mitsubishi Q/FX3U cap at <c>64</c>,
|
||||
/// Omron CJ/CS cap at <c>125</c>. Set to the lowest cap across the devices this driver
|
||||
/// instance talks to; the driver auto-chunks larger reads into consecutive requests.
|
||||
/// Default <c>125</c> — the spec maximum, safe against any conforming server. Setting
|
||||
/// to <c>0</c> disables the cap (discouraged — the spec upper bound still applies).
|
||||
/// </summary>
|
||||
public ushort MaxRegistersPerRead { get; init; } = 125;
|
||||
|
||||
/// <summary>
|
||||
/// Maximum registers per FC16 (Write Multiple Registers) transaction. Spec maximum is
|
||||
/// <c>123</c>; DL205/DL260 cap at <c>100</c>. Matching caller-vs-device semantics:
|
||||
/// exceeding the cap currently throws (writes aren't auto-chunked because a partial
|
||||
/// write across two FC16 calls is no longer atomic — caller must explicitly opt in
|
||||
/// by shortening the tag's <c>StringLength</c> or splitting it into multiple tags).
|
||||
/// </summary>
|
||||
public ushort MaxRegistersPerWrite { get; init; } = 123;
|
||||
}
|
||||
|
||||
public sealed class ModbusProbeOptions
|
||||
@@ -55,6 +75,12 @@ public sealed class ModbusProbeOptions
|
||||
/// <param name="ByteOrder">Word ordering for multi-register types. Ignored for Bool / Int16 / UInt16 / BitInRegister / String.</param>
|
||||
/// <param name="BitIndex">For <c>DataType = BitInRegister</c>: which bit of the holding register (0-15, LSB-first).</param>
|
||||
/// <param name="StringLength">For <c>DataType = String</c>: number of ASCII characters (2 per register, rounded up).</param>
|
||||
/// <param name="StringByteOrder">
|
||||
/// Per-register byte order for <c>DataType = String</c>. Standard Modbus packs the first
|
||||
/// character in the high byte (<see cref="ModbusStringByteOrder.HighByteFirst"/>).
|
||||
/// AutomationDirect DirectLOGIC (DL205/DL260) and a few legacy families pack the first
|
||||
/// character in the low byte instead — see <c>docs/v2/dl205.md</c> §strings.
|
||||
/// </param>
|
||||
public sealed record ModbusTagDefinition(
|
||||
string Name,
|
||||
ModbusRegion Region,
|
||||
@@ -63,7 +89,8 @@ public sealed record ModbusTagDefinition(
|
||||
bool Writable = true,
|
||||
ModbusByteOrder ByteOrder = ModbusByteOrder.BigEndian,
|
||||
byte BitIndex = 0,
|
||||
ushort StringLength = 0);
|
||||
ushort StringLength = 0,
|
||||
ModbusStringByteOrder StringByteOrder = ModbusStringByteOrder.HighByteFirst);
|
||||
|
||||
public enum ModbusRegion { Coils, DiscreteInputs, InputRegisters, HoldingRegisters }
|
||||
|
||||
@@ -82,6 +109,18 @@ public enum ModbusDataType
|
||||
BitInRegister,
|
||||
/// <summary>ASCII string packed 2 chars per register, <see cref="ModbusTagDefinition.StringLength"/> characters long.</summary>
|
||||
String,
|
||||
/// <summary>
|
||||
/// 16-bit binary-coded decimal. Each nibble encodes one decimal digit (0-9). Register
|
||||
/// value <c>0x1234</c> decodes as decimal <c>1234</c> — NOT binary <c>0x04D2 = 4660</c>.
|
||||
/// DL205/DL260 and several Mitsubishi / Omron families store timers, counters, and
|
||||
/// operator-facing numerics as BCD by default.
|
||||
/// </summary>
|
||||
Bcd16,
|
||||
/// <summary>
|
||||
/// 32-bit (two-register) BCD. Decodes 8 decimal digits. Word ordering follows
|
||||
/// <see cref="ModbusTagDefinition.ByteOrder"/> the same way <see cref="Int32"/> does.
|
||||
/// </summary>
|
||||
Bcd32,
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
@@ -95,3 +134,17 @@ public enum ModbusByteOrder
|
||||
BigEndian,
|
||||
WordSwap,
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Per-register byte order for ASCII strings packed 2 chars per register. Standard Modbus
|
||||
/// convention is <see cref="HighByteFirst"/> — the first character of each pair occupies
|
||||
/// the high byte of the register. AutomationDirect DirectLOGIC (DL205, DL260, DL350) and a
|
||||
/// handful of legacy controllers pack <see cref="LowByteFirst"/>, which inverts that within
|
||||
/// each register. Word ordering across multiple registers is always ascending address for
|
||||
/// strings — only the byte order inside each register flips.
|
||||
/// </summary>
|
||||
public enum ModbusStringByteOrder
|
||||
{
|
||||
HighByteFirst,
|
||||
LowByteFirst,
|
||||
}
|
||||
|
||||
@@ -28,10 +28,20 @@ public sealed class ModbusTcpTransport : IModbusTransport
|
||||
|
||||
public async Task ConnectAsync(CancellationToken ct)
|
||||
{
|
||||
_client = new TcpClient();
|
||||
// Resolve the host explicitly + prefer IPv4. .NET's TcpClient default-constructor is
|
||||
// dual-stack (IPv6 first, fallback to IPv4) — but most Modbus TCP devices (PLCs and
|
||||
// simulators like pymodbus) bind 0.0.0.0 only, so the IPv6 attempt times out and we
|
||||
// burn the entire ConnectAsync budget before even trying IPv4. Resolving first +
|
||||
// dialing the IPv4 address directly sidesteps that.
|
||||
var addresses = await System.Net.Dns.GetHostAddressesAsync(_host, ct).ConfigureAwait(false);
|
||||
var ipv4 = System.Linq.Enumerable.FirstOrDefault(addresses,
|
||||
a => a.AddressFamily == System.Net.Sockets.AddressFamily.InterNetwork);
|
||||
var target = ipv4 ?? (addresses.Length > 0 ? addresses[0] : System.Net.IPAddress.Loopback);
|
||||
|
||||
_client = new TcpClient(target.AddressFamily);
|
||||
using var cts = CancellationTokenSource.CreateLinkedTokenSource(ct);
|
||||
cts.CancelAfter(_timeout);
|
||||
await _client.ConnectAsync(_host, _port, cts.Token).ConfigureAwait(false);
|
||||
await _client.ConnectAsync(target, _port, cts.Token).ConfigureAwait(false);
|
||||
_stream = _client.GetStream();
|
||||
}
|
||||
|
||||
|
||||
@@ -0,0 +1,56 @@
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests.DL205;
|
||||
|
||||
/// <summary>
|
||||
/// Verifies DL205/DL260 binary-coded-decimal register handling against the
|
||||
/// <c>dl205.json</c> pymodbus profile. HR[1072] = 0x1234 on the profile represents
|
||||
/// decimal 1234 (BCD nibbles). Reading it as <see cref="ModbusDataType.Int16"/> would
|
||||
/// return 0x1234 = 4660; the <see cref="ModbusDataType.Bcd16"/> path decodes 1234.
|
||||
/// </summary>
|
||||
[Collection(ModbusSimulatorCollection.Name)]
|
||||
[Trait("Category", "Integration")]
|
||||
[Trait("Device", "DL205")]
|
||||
public sealed class DL205BcdQuirkTests(ModbusSimulatorFixture sim)
|
||||
{
|
||||
[Fact]
|
||||
public async Task DL205_BCD16_decodes_HR1072_as_decimal_1234()
|
||||
{
|
||||
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
|
||||
if (!string.Equals(Environment.GetEnvironmentVariable("MODBUS_SIM_PROFILE"), "dl205",
|
||||
StringComparison.OrdinalIgnoreCase))
|
||||
{
|
||||
Assert.Skip("MODBUS_SIM_PROFILE != dl205 — skipping (standard profile does not seed HR[1072]).");
|
||||
}
|
||||
|
||||
var options = new ModbusDriverOptions
|
||||
{
|
||||
Host = sim.Host,
|
||||
Port = sim.Port,
|
||||
UnitId = 1,
|
||||
Timeout = TimeSpan.FromSeconds(2),
|
||||
Tags =
|
||||
[
|
||||
new ModbusTagDefinition("DL205_Count_Bcd",
|
||||
ModbusRegion.HoldingRegisters, Address: 1072,
|
||||
DataType: ModbusDataType.Bcd16, Writable: false),
|
||||
new ModbusTagDefinition("DL205_Count_Int16",
|
||||
ModbusRegion.HoldingRegisters, Address: 1072,
|
||||
DataType: ModbusDataType.Int16, Writable: false),
|
||||
],
|
||||
Probe = new ModbusProbeOptions { Enabled = false },
|
||||
};
|
||||
await using var driver = new ModbusDriver(options, driverInstanceId: "dl205-bcd");
|
||||
await driver.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
|
||||
var results = await driver.ReadAsync(["DL205_Count_Bcd", "DL205_Count_Int16"],
|
||||
TestContext.Current.CancellationToken);
|
||||
|
||||
results[0].StatusCode.ShouldBe(0u);
|
||||
results[0].Value.ShouldBe(1234, "DL205 BCD register 0x1234 represents decimal 1234 per the DirectLOGIC convention");
|
||||
|
||||
results[1].StatusCode.ShouldBe(0u);
|
||||
results[1].Value.ShouldBe((short)0x1234, "same register read as Int16 returns the raw 0x1234 = 4660 value — proves BCD path is distinct");
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,109 @@
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests.DL205;
|
||||
|
||||
/// <summary>
|
||||
/// Verifies DL260 I/O-memory coil mappings against the <c>dl205.json</c> pymodbus profile.
|
||||
/// DirectLOGIC Y-outputs and C-relays are exposed to Modbus as FC01/FC05 coils, but at
|
||||
/// non-zero base addresses that confuse operators used to "Y0 is the first coil". The sim
|
||||
/// seeds Y0 → coil 2048 = ON and C0 → coil 3072 = ON as fixed markers.
|
||||
/// </summary>
|
||||
[Collection(ModbusSimulatorCollection.Name)]
|
||||
[Trait("Category", "Integration")]
|
||||
[Trait("Device", "DL205")]
|
||||
public sealed class DL205CoilMappingTests(ModbusSimulatorFixture sim)
|
||||
{
|
||||
[Fact]
|
||||
public async Task DL260_Y0_maps_to_coil_2048()
|
||||
{
|
||||
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
|
||||
if (!string.Equals(Environment.GetEnvironmentVariable("MODBUS_SIM_PROFILE"), "dl205",
|
||||
StringComparison.OrdinalIgnoreCase))
|
||||
{
|
||||
Assert.Skip("MODBUS_SIM_PROFILE != dl205 — skipping.");
|
||||
}
|
||||
|
||||
var coil = DirectLogicAddress.YOutputToCoil("Y0");
|
||||
coil.ShouldBe((ushort)2048);
|
||||
|
||||
var options = BuildOptions(sim, [
|
||||
new ModbusTagDefinition("DL260_Y0",
|
||||
ModbusRegion.Coils, Address: coil,
|
||||
DataType: ModbusDataType.Bool, Writable: false),
|
||||
]);
|
||||
await using var driver = new ModbusDriver(options, driverInstanceId: "dl205-y0");
|
||||
await driver.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
|
||||
var results = await driver.ReadAsync(["DL260_Y0"], TestContext.Current.CancellationToken);
|
||||
results[0].StatusCode.ShouldBe(0u);
|
||||
results[0].Value.ShouldBe(true, "dl205.json seeds coil 2048 (Y0) = ON");
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task DL260_C0_maps_to_coil_3072()
|
||||
{
|
||||
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
|
||||
if (!string.Equals(Environment.GetEnvironmentVariable("MODBUS_SIM_PROFILE"), "dl205",
|
||||
StringComparison.OrdinalIgnoreCase))
|
||||
{
|
||||
Assert.Skip("MODBUS_SIM_PROFILE != dl205 — skipping.");
|
||||
}
|
||||
|
||||
var coil = DirectLogicAddress.CRelayToCoil("C0");
|
||||
coil.ShouldBe((ushort)3072);
|
||||
|
||||
var options = BuildOptions(sim, [
|
||||
new ModbusTagDefinition("DL260_C0",
|
||||
ModbusRegion.Coils, Address: coil,
|
||||
DataType: ModbusDataType.Bool, Writable: false),
|
||||
]);
|
||||
await using var driver = new ModbusDriver(options, driverInstanceId: "dl205-c0");
|
||||
await driver.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
|
||||
var results = await driver.ReadAsync(["DL260_C0"], TestContext.Current.CancellationToken);
|
||||
results[0].StatusCode.ShouldBe(0u);
|
||||
results[0].Value.ShouldBe(true, "dl205.json seeds coil 3072 (C0) = ON");
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task DL260_scratch_Crelay_supports_write_then_read()
|
||||
{
|
||||
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
|
||||
if (!string.Equals(Environment.GetEnvironmentVariable("MODBUS_SIM_PROFILE"), "dl205",
|
||||
StringComparison.OrdinalIgnoreCase))
|
||||
{
|
||||
Assert.Skip("MODBUS_SIM_PROFILE != dl205 — skipping.");
|
||||
}
|
||||
|
||||
// Scratch C-relay at coil 4000 (per dl205.json _quirk note) is writable. Write=true then
|
||||
// read back to confirm FC05 round-trip works against the DL-mapped coil bank.
|
||||
var options = BuildOptions(sim, [
|
||||
new ModbusTagDefinition("DL260_C_Scratch",
|
||||
ModbusRegion.Coils, Address: 4000,
|
||||
DataType: ModbusDataType.Bool, Writable: true),
|
||||
]);
|
||||
await using var driver = new ModbusDriver(options, driverInstanceId: "dl205-cscratch");
|
||||
await driver.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
|
||||
var writeResults = await driver.WriteAsync(
|
||||
[new(FullReference: "DL260_C_Scratch", Value: true)],
|
||||
TestContext.Current.CancellationToken);
|
||||
writeResults[0].StatusCode.ShouldBe(0u);
|
||||
|
||||
var readResults = await driver.ReadAsync(["DL260_C_Scratch"], TestContext.Current.CancellationToken);
|
||||
readResults[0].StatusCode.ShouldBe(0u);
|
||||
readResults[0].Value.ShouldBe(true);
|
||||
}
|
||||
|
||||
private static ModbusDriverOptions BuildOptions(ModbusSimulatorFixture sim, IReadOnlyList<ModbusTagDefinition> tags)
|
||||
=> new()
|
||||
{
|
||||
Host = sim.Host,
|
||||
Port = sim.Port,
|
||||
UnitId = 1,
|
||||
Timeout = TimeSpan.FromSeconds(2),
|
||||
Tags = tags,
|
||||
Probe = new ModbusProbeOptions { Enabled = false },
|
||||
};
|
||||
}
|
||||
@@ -0,0 +1,53 @@
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests.DL205;
|
||||
|
||||
/// <summary>
|
||||
/// Verifies the driver's Modbus-exception → OPC UA StatusCode translation end-to-end
|
||||
/// against the dl205.json pymodbus profile. pymodbus returns exception 02 (Illegal Data
|
||||
/// Address) for reads outside the configured register ranges, matching real DL205/DL260
|
||||
/// firmware behavior per <c>docs/v2/dl205.md</c> §exception-codes. The driver must surface
|
||||
/// that as <c>BadOutOfRange</c> (0x803C0000) — not <c>BadInternalError</c> — so the
|
||||
/// operator sees a tag-config diagnosis instead of a generic driver-fault message.
|
||||
/// </summary>
|
||||
[Collection(ModbusSimulatorCollection.Name)]
|
||||
[Trait("Category", "Integration")]
|
||||
[Trait("Device", "DL205")]
|
||||
public sealed class DL205ExceptionCodeTests(ModbusSimulatorFixture sim)
|
||||
{
|
||||
[Fact]
|
||||
public async Task DL205_FC03_at_unmapped_register_returns_BadOutOfRange()
|
||||
{
|
||||
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
|
||||
if (!string.Equals(Environment.GetEnvironmentVariable("MODBUS_SIM_PROFILE"), "dl205",
|
||||
StringComparison.OrdinalIgnoreCase))
|
||||
{
|
||||
Assert.Skip("MODBUS_SIM_PROFILE != dl205 — skipping.");
|
||||
}
|
||||
|
||||
// Address 16383 is the last cell of hr-size=16384 in dl205.json; address 16384 is
|
||||
// beyond the configured HR range. pymodbus validates and returns exception 02
|
||||
// (Illegal Data Address).
|
||||
var options = new ModbusDriverOptions
|
||||
{
|
||||
Host = sim.Host,
|
||||
Port = sim.Port,
|
||||
UnitId = 1,
|
||||
Timeout = TimeSpan.FromSeconds(2),
|
||||
Tags =
|
||||
[
|
||||
new ModbusTagDefinition("Unmapped",
|
||||
ModbusRegion.HoldingRegisters, Address: 16383,
|
||||
DataType: ModbusDataType.UInt16, Writable: false),
|
||||
],
|
||||
Probe = new ModbusProbeOptions { Enabled = false },
|
||||
};
|
||||
await using var driver = new ModbusDriver(options, driverInstanceId: "dl205-exc");
|
||||
await driver.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
|
||||
var results = await driver.ReadAsync(["Unmapped"], TestContext.Current.CancellationToken);
|
||||
results[0].StatusCode.ShouldBe(0x803C0000u,
|
||||
"DL205 returns exception 02 for an FC03 at an unmapped register; driver must translate to BadOutOfRange (not BadInternalError)");
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,64 @@
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests.DL205;
|
||||
|
||||
/// <summary>
|
||||
/// Verifies DL205/DL260 CDAB word ordering for 32-bit floats against the
|
||||
/// <c>dl205.json</c> pymodbus profile. DirectLOGIC stores IEEE-754 singles with the low
|
||||
/// word at the lower register address (CDAB) rather than the high word (ABCD). Reading
|
||||
/// <c>HR[1056..1057]</c> with <see cref="ModbusByteOrder.BigEndian"/> produces a tiny
|
||||
/// denormal (~5.74e-41) instead of the intended 1.5f — a silent "value is 0" bug in the
|
||||
/// field unless the caller opts into <see cref="ModbusByteOrder.WordSwap"/>.
|
||||
/// </summary>
|
||||
[Collection(ModbusSimulatorCollection.Name)]
|
||||
[Trait("Category", "Integration")]
|
||||
[Trait("Device", "DL205")]
|
||||
public sealed class DL205FloatCdabQuirkTests(ModbusSimulatorFixture sim)
|
||||
{
|
||||
[Fact]
|
||||
public async Task DL205_Float32_CDAB_decodes_1_5f_from_HR1056()
|
||||
{
|
||||
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
|
||||
if (!string.Equals(Environment.GetEnvironmentVariable("MODBUS_SIM_PROFILE"), "dl205",
|
||||
StringComparison.OrdinalIgnoreCase))
|
||||
{
|
||||
Assert.Skip("MODBUS_SIM_PROFILE != dl205 — skipping (standard profile does not seed HR[1056..1057]).");
|
||||
}
|
||||
|
||||
var options = new ModbusDriverOptions
|
||||
{
|
||||
Host = sim.Host,
|
||||
Port = sim.Port,
|
||||
UnitId = 1,
|
||||
Timeout = TimeSpan.FromSeconds(2),
|
||||
Tags =
|
||||
[
|
||||
new ModbusTagDefinition("DL205_Float_CDAB",
|
||||
ModbusRegion.HoldingRegisters, Address: 1056,
|
||||
DataType: ModbusDataType.Float32, Writable: false,
|
||||
ByteOrder: ModbusByteOrder.WordSwap),
|
||||
// Control: same address, BigEndian — proves the default decode produces garbage.
|
||||
new ModbusTagDefinition("DL205_Float_ABCD",
|
||||
ModbusRegion.HoldingRegisters, Address: 1056,
|
||||
DataType: ModbusDataType.Float32, Writable: false,
|
||||
ByteOrder: ModbusByteOrder.BigEndian),
|
||||
],
|
||||
Probe = new ModbusProbeOptions { Enabled = false },
|
||||
};
|
||||
await using var driver = new ModbusDriver(options, driverInstanceId: "dl205-cdab");
|
||||
await driver.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
|
||||
var results = await driver.ReadAsync(["DL205_Float_CDAB", "DL205_Float_ABCD"],
|
||||
TestContext.Current.CancellationToken);
|
||||
|
||||
results[0].StatusCode.ShouldBe(0u);
|
||||
results[0].Value.ShouldBe(1.5f, "DL205 Float32 with WordSwap (CDAB) must decode HR[1056..1057] as 1.5f");
|
||||
|
||||
// The BigEndian read of the same wire bytes should differ — not asserting the exact
|
||||
// denormal value (that couples the test to IEEE-754 bit math) but the two decodes MUST
|
||||
// disagree, otherwise the word-order flag is a no-op.
|
||||
results[1].StatusCode.ShouldBe(0u);
|
||||
results[1].Value.ShouldNotBe(1.5f);
|
||||
}
|
||||
}
|
||||
@@ -1,26 +1,30 @@
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests.DL205;
|
||||
|
||||
/// <summary>
|
||||
/// Tag map for the AutomationDirect DL205 device class. Mirrors what the ModbusPal
|
||||
/// <c>.xmpp</c> profile in <c>ModbusPal/DL205.xmpp</c> exposes (or the real PLC, when
|
||||
/// Tag map for the AutomationDirect DL205 device class. Mirrors what the pymodbus
|
||||
/// <c>dl205.json</c> profile in <c>Pymodbus/dl205.json</c> exposes (or the real PLC, when
|
||||
/// <see cref="ModbusSimulatorFixture"/> is pointed at one).
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// This is the scaffold — each tag is deliberately generic so the smoke test has stable
|
||||
/// addresses to read. Device-specific quirk tests (word order, max-register, register-zero
|
||||
/// access, etc.) will land in their own test classes alongside this profile as the user
|
||||
/// validates each behavior in ModbusPal; see <c>docs/v2/modbus-test-plan.md</c> §per-device
|
||||
/// validates each behavior in pymodbus; see <c>docs/v2/modbus-test-plan.md</c> §per-device
|
||||
/// quirk catalog for the checklist.
|
||||
/// </remarks>
|
||||
public static class DL205Profile
|
||||
{
|
||||
/// <summary>Holding register the smoke test reads. Address 100 sidesteps the DL205
|
||||
/// register-zero quirk (pending confirmation) — see modbus-test-plan.md.</summary>
|
||||
public const ushort SmokeHoldingRegister = 100;
|
||||
/// <summary>
|
||||
/// Holding register the smoke test writes + reads. Address 200 is the first cell of the
|
||||
/// scratch HR range in both <c>Pymodbus/standard.json</c> (HR[200..209] = 0) and
|
||||
/// <c>Pymodbus/dl205.json</c> (HR[4096..4103] added in PR 43 for the same purpose), so
|
||||
/// the smoke test runs identically against either simulator profile. Originally
|
||||
/// targeted HR[100] — moved to HR[200] when the standard profile claimed HR[100] as
|
||||
/// the auto-incrementing register that drives subscribe-and-receive tests.
|
||||
/// </summary>
|
||||
public const ushort SmokeHoldingRegister = 200;
|
||||
|
||||
/// <summary>Expected value the ModbusPal profile seeds into register 100. When running
|
||||
/// against a real DL205 (or a ModbusPal profile where this register is writable), the smoke
|
||||
/// test seeds this value first, then reads it back.</summary>
|
||||
/// <summary>Value the smoke test writes then reads back to assert round-trip integrity.</summary>
|
||||
public const short SmokeHoldingValue = 1234;
|
||||
|
||||
public static ModbusDriverOptions BuildOptions(string host, int port) => new()
|
||||
@@ -32,7 +36,7 @@ public static class DL205Profile
|
||||
Tags =
|
||||
[
|
||||
new ModbusTagDefinition(
|
||||
Name: "DL205_Smoke_HReg100",
|
||||
Name: "Smoke_HReg200",
|
||||
Region: ModbusRegion.HoldingRegisters,
|
||||
Address: SmokeHoldingRegister,
|
||||
DataType: ModbusDataType.Int16,
|
||||
|
||||
@@ -38,13 +38,13 @@ public sealed class DL205SmokeTests(ModbusSimulatorFixture sim)
|
||||
// zeroed at simulator start, and tests must not depend on prior-test state per the
|
||||
// test-plan conventions.
|
||||
var writeResults = await driver.WriteAsync(
|
||||
[new(FullReference: "DL205_Smoke_HReg100", Value: (short)DL205Profile.SmokeHoldingValue)],
|
||||
[new(FullReference: "Smoke_HReg200", Value: (short)DL205Profile.SmokeHoldingValue)],
|
||||
TestContext.Current.CancellationToken);
|
||||
writeResults.Count.ShouldBe(1);
|
||||
writeResults[0].StatusCode.ShouldBe(0u, "write must succeed against the ModbusPal DL205 profile");
|
||||
|
||||
var readResults = await driver.ReadAsync(
|
||||
["DL205_Smoke_HReg100"],
|
||||
["Smoke_HReg200"],
|
||||
TestContext.Current.CancellationToken);
|
||||
readResults.Count.ShouldBe(1);
|
||||
readResults[0].StatusCode.ShouldBe(0u);
|
||||
|
||||
@@ -0,0 +1,81 @@
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests.DL205;
|
||||
|
||||
/// <summary>
|
||||
/// Verifies the DL205/DL260 low-byte-first ASCII string packing quirk against the
|
||||
/// <c>dl205.json</c> pymodbus profile. Standard Modbus packs the first char of each pair
|
||||
/// in the high byte of the register; DirectLOGIC packs it in the low byte instead. Without
|
||||
/// <see cref="ModbusStringByteOrder.LowByteFirst"/> the driver decodes "eHllo" garbage
|
||||
/// even though the bytes on the wire are identical.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// <para>
|
||||
/// Requires the dl205 profile (<c>Pymodbus\serve.ps1 -Profile dl205</c>). The standard
|
||||
/// profile does not seed HR[1040..1042] with string bytes, so running this against the
|
||||
/// standard profile returns <c>"\0\0\0\0\0"</c> and the test fails. Skip when the env
|
||||
/// var <c>MODBUS_SIM_PROFILE</c> is not set to <c>dl205</c>.
|
||||
/// </para>
|
||||
/// </remarks>
|
||||
[Collection(ModbusSimulatorCollection.Name)]
|
||||
[Trait("Category", "Integration")]
|
||||
[Trait("Device", "DL205")]
|
||||
public sealed class DL205StringQuirkTests(ModbusSimulatorFixture sim)
|
||||
{
|
||||
[Fact]
|
||||
public async Task DL205_string_low_byte_first_decodes_Hello_from_HR1040()
|
||||
{
|
||||
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
|
||||
if (!string.Equals(Environment.GetEnvironmentVariable("MODBUS_SIM_PROFILE"), "dl205",
|
||||
StringComparison.OrdinalIgnoreCase))
|
||||
{
|
||||
Assert.Skip("MODBUS_SIM_PROFILE != dl205 — skipping (standard profile does not seed HR[1040..1042]).");
|
||||
}
|
||||
|
||||
var options = new ModbusDriverOptions
|
||||
{
|
||||
Host = sim.Host,
|
||||
Port = sim.Port,
|
||||
UnitId = 1,
|
||||
Timeout = TimeSpan.FromSeconds(2),
|
||||
Tags =
|
||||
[
|
||||
new ModbusTagDefinition(
|
||||
Name: "DL205_Hello_Low",
|
||||
Region: ModbusRegion.HoldingRegisters,
|
||||
Address: 1040,
|
||||
DataType: ModbusDataType.String,
|
||||
Writable: false,
|
||||
StringLength: 5,
|
||||
StringByteOrder: ModbusStringByteOrder.LowByteFirst),
|
||||
// Control: same address, HighByteFirst, to prove the driver would have decoded
|
||||
// garbage without the quirk flag.
|
||||
new ModbusTagDefinition(
|
||||
Name: "DL205_Hello_High",
|
||||
Region: ModbusRegion.HoldingRegisters,
|
||||
Address: 1040,
|
||||
DataType: ModbusDataType.String,
|
||||
Writable: false,
|
||||
StringLength: 5,
|
||||
StringByteOrder: ModbusStringByteOrder.HighByteFirst),
|
||||
],
|
||||
Probe = new ModbusProbeOptions { Enabled = false },
|
||||
};
|
||||
await using var driver = new ModbusDriver(options, driverInstanceId: "dl205-string");
|
||||
await driver.InitializeAsync(driverConfigJson: "{}", TestContext.Current.CancellationToken);
|
||||
|
||||
var results = await driver.ReadAsync(["DL205_Hello_Low", "DL205_Hello_High"],
|
||||
TestContext.Current.CancellationToken);
|
||||
|
||||
results.Count.ShouldBe(2);
|
||||
results[0].StatusCode.ShouldBe(0u);
|
||||
results[0].Value.ShouldBe("Hello", "DL205 low-byte-first ordering must produce 'Hello' from HR[1040..1042]");
|
||||
|
||||
// The high-byte-first read of the same wire bytes should differ — not asserting the
|
||||
// exact garbage string (that would couple the test to the ASCII byte math) but the two
|
||||
// decodes MUST disagree, otherwise the quirk flag is a no-op.
|
||||
results[1].StatusCode.ShouldBe(0u);
|
||||
results[1].Value.ShouldNotBe("Hello");
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,91 @@
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests.DL205;
|
||||
|
||||
/// <summary>
|
||||
/// Verifies the DL205/DL260 V-memory octal addressing quirk end-to-end: use
|
||||
/// <see cref="DirectLogicAddress.UserVMemoryToPdu"/> to translate <c>V2000</c> octal into
|
||||
/// the Modbus PDU address actually dispatched, then read the marker the dl205.json profile
|
||||
/// placed at that address. HR[0x0400] = 0x2000 proves the translation was performed
|
||||
/// correctly — a naïve caller treating "V2000" as decimal 2000 would read HR[2000] (which
|
||||
/// the profile leaves at 0) and miss the marker entirely.
|
||||
/// </summary>
|
||||
[Collection(ModbusSimulatorCollection.Name)]
|
||||
[Trait("Category", "Integration")]
|
||||
[Trait("Device", "DL205")]
|
||||
public sealed class DL205VMemoryQuirkTests(ModbusSimulatorFixture sim)
|
||||
{
|
||||
[Fact]
|
||||
public async Task DL205_V2000_user_memory_resolves_to_PDU_0x0400_marker()
|
||||
{
|
||||
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
|
||||
if (!string.Equals(Environment.GetEnvironmentVariable("MODBUS_SIM_PROFILE"), "dl205",
|
||||
StringComparison.OrdinalIgnoreCase))
|
||||
{
|
||||
Assert.Skip("MODBUS_SIM_PROFILE != dl205 — skipping (standard profile does not seed V-memory markers).");
|
||||
}
|
||||
|
||||
var pdu = DirectLogicAddress.UserVMemoryToPdu("V2000");
|
||||
pdu.ShouldBe((ushort)0x0400);
|
||||
|
||||
var options = new ModbusDriverOptions
|
||||
{
|
||||
Host = sim.Host,
|
||||
Port = sim.Port,
|
||||
UnitId = 1,
|
||||
Timeout = TimeSpan.FromSeconds(2),
|
||||
Tags =
|
||||
[
|
||||
new ModbusTagDefinition("DL205_V2000",
|
||||
ModbusRegion.HoldingRegisters, Address: pdu,
|
||||
DataType: ModbusDataType.UInt16, Writable: false),
|
||||
],
|
||||
Probe = new ModbusProbeOptions { Enabled = false },
|
||||
};
|
||||
await using var driver = new ModbusDriver(options, driverInstanceId: "dl205-vmem");
|
||||
await driver.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
|
||||
var results = await driver.ReadAsync(["DL205_V2000"], TestContext.Current.CancellationToken);
|
||||
results[0].StatusCode.ShouldBe(0u);
|
||||
results[0].Value.ShouldBe((ushort)0x2000, "dl205.json seeds HR[0x0400] with marker 0x2000 (= V2000 value)");
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task DL205_V40400_system_memory_resolves_to_PDU_0x2100_marker()
|
||||
{
|
||||
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
|
||||
if (!string.Equals(Environment.GetEnvironmentVariable("MODBUS_SIM_PROFILE"), "dl205",
|
||||
StringComparison.OrdinalIgnoreCase))
|
||||
{
|
||||
Assert.Skip("MODBUS_SIM_PROFILE != dl205 — skipping.");
|
||||
}
|
||||
|
||||
// V40400 is system memory on DL260 / H2-ECOM100 absolute mode; it does NOT follow the
|
||||
// simple octal-to-decimal formula (40400 octal = 16640 decimal, which would read HR[0x4100]).
|
||||
// The CPU places the system bank at PDU 0x2100 instead. Proving the helper routes there.
|
||||
var pdu = DirectLogicAddress.SystemVMemoryToPdu(0);
|
||||
pdu.ShouldBe((ushort)0x2100);
|
||||
|
||||
var options = new ModbusDriverOptions
|
||||
{
|
||||
Host = sim.Host,
|
||||
Port = sim.Port,
|
||||
UnitId = 1,
|
||||
Timeout = TimeSpan.FromSeconds(2),
|
||||
Tags =
|
||||
[
|
||||
new ModbusTagDefinition("DL205_V40400",
|
||||
ModbusRegion.HoldingRegisters, Address: pdu,
|
||||
DataType: ModbusDataType.UInt16, Writable: false),
|
||||
],
|
||||
Probe = new ModbusProbeOptions { Enabled = false },
|
||||
};
|
||||
await using var driver = new ModbusDriver(options, driverInstanceId: "dl205-sysv");
|
||||
await driver.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
|
||||
var results = await driver.ReadAsync(["DL205_V40400"], TestContext.Current.CancellationToken);
|
||||
results[0].StatusCode.ShouldBe(0u);
|
||||
results[0].Value.ShouldBe((ushort)0x4040, "dl205.json seeds HR[0x2100] with marker 0x4040 (= V40400 value)");
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,71 @@
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests.DL205;
|
||||
|
||||
/// <summary>
|
||||
/// Verifies the DL260 X-input discrete-input mapping against the <c>dl205.json</c>
|
||||
/// pymodbus profile. X-inputs are FC02 discrete-input-only (Modbus doesn't allow writes
|
||||
/// to discrete inputs), and the DirectLOGIC convention is X0 → DI 0 with octal offsets
|
||||
/// for subsequent addresses. The sim seeds X20 octal (= DI 16) = ON so the test can
|
||||
/// prove the helper routes through to the right cell.
|
||||
/// </summary>
|
||||
/// <remarks>
|
||||
/// X0 / X1 / …X17 octal all share cell 0 (DI 0-15 → cell 0 bits 0-15) which conflicts
|
||||
/// with the V0 uint16 marker; we can't seed both types at cell 0 under shared-blocks
|
||||
/// semantics. So the test uses X20 octal (first address beyond the cell-0 boundary) which
|
||||
/// lands cleanly at cell 1 bit 0 and leaves the V0 register-zero quirk intact.
|
||||
/// </remarks>
|
||||
[Collection(ModbusSimulatorCollection.Name)]
|
||||
[Trait("Category", "Integration")]
|
||||
[Trait("Device", "DL205")]
|
||||
public sealed class DL205XInputTests(ModbusSimulatorFixture sim)
|
||||
{
|
||||
[Fact]
|
||||
public async Task DL260_X20_octal_maps_to_DiscreteInput_16_and_reads_ON()
|
||||
{
|
||||
if (sim.SkipReason is not null) Assert.Skip(sim.SkipReason);
|
||||
if (!string.Equals(Environment.GetEnvironmentVariable("MODBUS_SIM_PROFILE"), "dl205",
|
||||
StringComparison.OrdinalIgnoreCase))
|
||||
{
|
||||
Assert.Skip("MODBUS_SIM_PROFILE != dl205 — skipping.");
|
||||
}
|
||||
|
||||
// X20 octal = decimal 16 = DI 16 per the DL260 convention (X-inputs start at DI 0).
|
||||
var di = DirectLogicAddress.XInputToDiscrete("X20");
|
||||
di.ShouldBe((ushort)16);
|
||||
|
||||
var options = BuildOptions(sim, [
|
||||
new ModbusTagDefinition("DL260_X20",
|
||||
ModbusRegion.DiscreteInputs, Address: di,
|
||||
DataType: ModbusDataType.Bool, Writable: false),
|
||||
// Unpopulated-X control: pymodbus returns 0 (not exception) for any bit in the
|
||||
// configured DI range that wasn't explicitly seeded — per docs/v2/dl205.md
|
||||
// "Reading a non-populated X input ... returns zero, not an exception".
|
||||
new ModbusTagDefinition("DL260_X21_off",
|
||||
ModbusRegion.DiscreteInputs, Address: DirectLogicAddress.XInputToDiscrete("X21"),
|
||||
DataType: ModbusDataType.Bool, Writable: false),
|
||||
]);
|
||||
await using var driver = new ModbusDriver(options, driverInstanceId: "dl205-xinput");
|
||||
await driver.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
|
||||
var results = await driver.ReadAsync(["DL260_X20", "DL260_X21_off"], TestContext.Current.CancellationToken);
|
||||
|
||||
results[0].StatusCode.ShouldBe(0u);
|
||||
results[0].Value.ShouldBe(true, "dl205.json seeds cell 1 bit 0 (X20 octal = DI 16) = ON");
|
||||
|
||||
results[1].StatusCode.ShouldBe(0u, "unpopulated X inputs must read cleanly — DL260 does NOT raise an exception");
|
||||
results[1].Value.ShouldBe(false);
|
||||
}
|
||||
|
||||
private static ModbusDriverOptions BuildOptions(ModbusSimulatorFixture sim, IReadOnlyList<ModbusTagDefinition> tags)
|
||||
=> new()
|
||||
{
|
||||
Host = sim.Host,
|
||||
Port = sim.Port,
|
||||
UnitId = 1,
|
||||
Timeout = TimeSpan.FromSeconds(2),
|
||||
Tags = tags,
|
||||
Probe = new ModbusProbeOptions { Enabled = false },
|
||||
};
|
||||
}
|
||||
@@ -1,30 +0,0 @@
|
||||
# ModbusPal simulator profiles
|
||||
|
||||
Drop device-specific `.xmpp` profiles here. The integration tests connect to the
|
||||
endpoint in `MODBUS_SIM_ENDPOINT` (default `localhost:502`) and expect the
|
||||
simulator to already be running — tests do not launch ModbusPal themselves,
|
||||
because its Java GUI + JRE requirement is heavier than the harness is worth.
|
||||
|
||||
## Getting started
|
||||
|
||||
1. Download ModbusPal from SourceForge (`modbuspal.jar`).
|
||||
2. `java -jar modbuspal.jar` to launch the GUI.
|
||||
3. Load a profile from this directory (or configure one manually) and start the
|
||||
simulator on TCP port 502.
|
||||
4. `dotnet test tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests` — tests
|
||||
auto-skip with a clear `SkipReason` if the TCP probe at the configured
|
||||
endpoint fails within 2 seconds.
|
||||
|
||||
## Profile files
|
||||
|
||||
- `DL205.xmpp` — _to be added_ — register map reflecting the AutomationDirect
|
||||
DL205 quirks tracked in `docs/v2/modbus-test-plan.md`. The scaffolded smoke
|
||||
test in `DL205/DL205SmokeTests.cs` needs holding register 100 writable and
|
||||
present; a minimal ModbusPal profile with a single holding-register bank at
|
||||
address 100 is sufficient.
|
||||
|
||||
## Environment variables
|
||||
|
||||
- `MODBUS_SIM_ENDPOINT` — override the simulator endpoint. Accepts `host:port`;
|
||||
defaults to `localhost:502`. Useful when pointing the suite at a real PLC on
|
||||
the bench.
|
||||
@@ -3,8 +3,9 @@ using System.Net.Sockets;
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests;
|
||||
|
||||
/// <summary>
|
||||
/// Reachability probe for a Modbus TCP simulator (ModbusPal or a real PLC). Parses
|
||||
/// <c>MODBUS_SIM_ENDPOINT</c> (default <c>localhost:502</c>) and TCP-connects once at
|
||||
/// Reachability probe for a Modbus TCP simulator (pymodbus-driven, see
|
||||
/// <c>Pymodbus/serve.ps1</c>) or a real PLC. Parses
|
||||
/// <c>MODBUS_SIM_ENDPOINT</c> (default <c>localhost:5020</c> per PR 43) and TCP-connects once at
|
||||
/// fixture construction. Each test checks <see cref="SkipReason"/> and calls
|
||||
/// <c>Assert.Skip</c> when the endpoint was unreachable, so a dev box without a running
|
||||
/// simulator still passes `dotnet test` cleanly — matches the Galaxy live-smoke pattern in
|
||||
@@ -25,7 +26,11 @@ namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests;
|
||||
/// </remarks>
|
||||
public sealed class ModbusSimulatorFixture : IAsyncDisposable
|
||||
{
|
||||
private const string DefaultEndpoint = "localhost:502";
|
||||
// PR 43: default port is 5020 (pymodbus convention) instead of 502 (Modbus standard).
|
||||
// Picking 5020 sidesteps the privileged-port admin requirement on Windows + matches the
|
||||
// port baked into the pymodbus simulator JSON profiles in Pymodbus/. Override with
|
||||
// MODBUS_SIM_ENDPOINT to point at a real PLC on its native port 502.
|
||||
private const string DefaultEndpoint = "localhost:5020";
|
||||
private const string EndpointEnvVar = "MODBUS_SIM_ENDPOINT";
|
||||
|
||||
public string Host { get; }
|
||||
@@ -41,18 +46,30 @@ public sealed class ModbusSimulatorFixture : IAsyncDisposable
|
||||
|
||||
try
|
||||
{
|
||||
using var client = new TcpClient();
|
||||
var task = client.ConnectAsync(Host, Port);
|
||||
// Force IPv4 family on the probe — pymodbus's TCP server binds 0.0.0.0 (IPv4 only)
|
||||
// while .NET's TcpClient default-resolves "localhost" → IPv6 ::1 first, fails to
|
||||
// connect, and only then tries IPv4. Under .NET 10 the IPv6 fail surfaces as a
|
||||
// 2s timeout (no graceful fallback by default), so the C# probe times out even
|
||||
// though a PowerShell probe of the same endpoint succeeds. Resolving + dialing
|
||||
// explicit IPv4 sidesteps the dual-stack ordering.
|
||||
using var client = new TcpClient(System.Net.Sockets.AddressFamily.InterNetwork);
|
||||
var task = client.ConnectAsync(
|
||||
System.Net.Dns.GetHostAddresses(Host)
|
||||
.FirstOrDefault(a => a.AddressFamily == System.Net.Sockets.AddressFamily.InterNetwork)
|
||||
?? System.Net.IPAddress.Loopback,
|
||||
Port);
|
||||
if (!task.Wait(TimeSpan.FromSeconds(2)) || !client.Connected)
|
||||
{
|
||||
SkipReason = $"Modbus simulator at {Host}:{Port} did not accept a TCP connection within 2s. " +
|
||||
$"Start ModbusPal (or override {EndpointEnvVar}) and re-run.";
|
||||
$"Start the pymodbus simulator (Pymodbus\\serve.ps1 -Profile standard) " +
|
||||
$"or override {EndpointEnvVar}, then re-run.";
|
||||
}
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
SkipReason = $"Modbus simulator at {Host}:{Port} unreachable: {ex.GetType().Name}: {ex.Message}. " +
|
||||
$"Start ModbusPal (or override {EndpointEnvVar}) and re-run.";
|
||||
$"Start the pymodbus simulator (Pymodbus\\serve.ps1 -Profile standard) " +
|
||||
$"or override {EndpointEnvVar}, then re-run.";
|
||||
}
|
||||
}
|
||||
|
||||
|
||||
@@ -0,0 +1,163 @@
|
||||
# pymodbus simulator profiles
|
||||
|
||||
Two JSON-config profiles for pymodbus's `ModbusSimulatorServer`. Replaces the
|
||||
ModbusPal `.xmpp` profiles that lived here in PR 42 — pymodbus is headless,
|
||||
maintained, semantic about register layout, and pip-installable on Windows.
|
||||
|
||||
| File | What it simulates | Test category |
|
||||
|---|---|---|
|
||||
| [`standard.json`](standard.json) | Generic Modbus TCP server — HR[0..31] = address-as-value, HR[100] declarative auto-increment via `"action": "increment"`, alternating coils, scratch ranges for write tests. | `Trait=Standard` |
|
||||
| [`dl205.json`](dl205.json) | AutomationDirect DirectLOGIC DL205 / DL260 quirks per [`docs/v2/dl205.md`](../../../docs/v2/dl205.md): low-byte-first string packing, CDAB Float32, BCD numerics, V-memory address markers, Y/C coil mappings. Inline `_quirk` comments per register name the behavior. | `Trait=DL205` |
|
||||
|
||||
Both bind TCP **5020** (pymodbus convention; sidesteps the Windows admin
|
||||
requirement for privileged port 502). The integration-test fixture
|
||||
(`ModbusSimulatorFixture`) defaults to `localhost:5020` to match — override
|
||||
via `MODBUS_SIM_ENDPOINT` to point at a real PLC on its native port 502.
|
||||
|
||||
Run only **one profile at a time** (they share TCP 5020).
|
||||
|
||||
## Install
|
||||
|
||||
```powershell
|
||||
pip install "pymodbus[simulator]==3.13.0"
|
||||
```
|
||||
|
||||
The `[simulator]` extra pulls in `aiohttp` for the optional web UI / REST API.
|
||||
Pinned to 3.13.0 for reproducibility — avoid 4.x dev releases until stabilized.
|
||||
Requires Python ≥ 3.10. Windows Firewall will prompt on first bind; allow
|
||||
Private network.
|
||||
|
||||
## Run
|
||||
|
||||
Foreground (Ctrl+C to stop). Use the `serve.ps1` wrapper:
|
||||
|
||||
```powershell
|
||||
.\serve.ps1 -Profile standard
|
||||
.\serve.ps1 -Profile dl205
|
||||
```
|
||||
|
||||
Or invoke pymodbus directly:
|
||||
|
||||
```powershell
|
||||
pymodbus.simulator `
|
||||
--modbus_server srv `
|
||||
--modbus_device dev `
|
||||
--json_file .\standard.json `
|
||||
--http_port 8080
|
||||
```
|
||||
|
||||
Web UI at `http://localhost:8080` lets you inspect + poke registers manually.
|
||||
Pass `--no_http` (or `-HttpPort 0` to `serve.ps1`) to disable.
|
||||
|
||||
## Run the integration tests
|
||||
|
||||
In a separate shell, with the simulator running:
|
||||
|
||||
```powershell
|
||||
cd C:\Users\dohertj2\Desktop\lmxopcua
|
||||
dotnet test tests\ZB.MOM.WW.OtOpcUa.Driver.Modbus.IntegrationTests
|
||||
```
|
||||
|
||||
Tests auto-skip with a clear `SkipReason` if `localhost:5020` isn't reachable
|
||||
within 2 seconds. Filter by trait when both profiles' tests coexist:
|
||||
|
||||
```powershell
|
||||
dotnet test ... --filter "Trait=Standard"
|
||||
dotnet test ... --filter "Trait=DL205"
|
||||
```
|
||||
|
||||
## What's encoded in each profile
|
||||
|
||||
### standard.json
|
||||
|
||||
- HR[0..31]: each register's value equals its address. Easy mental map.
|
||||
- HR[100]: `"action": "increment"` ticks 0..65535 on every register access — drives subscribe-and-receive tests so they have a register that changes without a write.
|
||||
- HR[200..209]: scratch range for write-roundtrip tests.
|
||||
- Coils[0..31]: alternating on/off (even=on).
|
||||
- Coils[100..109]: scratch.
|
||||
- All addresses 0..1023 are writable (`"write": [[0, 1023]]`).
|
||||
|
||||
### dl205.json (per `docs/v2/dl205.md`)
|
||||
|
||||
| HR address | Quirk demonstrated | Raw value | Decoded |
|
||||
|---|---|---|---|
|
||||
| `0` (V0) | Register 0 is valid (rejects-register-0 rumour disproved) | `51966` (0xCAFE) | marker |
|
||||
| `1024` (V2000 octal) | V-memory octal-to-decimal mapping | `8192` (0x2000) | marker |
|
||||
| `8448` (V40400 octal) | V40400 → PDU 0x2100 (NOT register 0) | `16448` (0x4040) | marker |
|
||||
| `1040..1042` | String "Hello" packed first-char-low-byte | `25928, 27756, 111` | `"Hello"` |
|
||||
| `1056..1057` | Float32 1.5f in CDAB word order | `0, 16320` | `1.5f` |
|
||||
| `1072` | Decimal 1234 in BCD encoding | `4660` (0x1234) | `1234` |
|
||||
| `1280..1407` | 128-register block (FC03 cap = 128 above spec's 125) | first/last/mid markers; rest defaults to 0 | for FC03 cap test |
|
||||
|
||||
| Coil address | Quirk demonstrated |
|
||||
|---|---|
|
||||
| `2048` | Y0 maps to coil 2048 (DL260 layout) |
|
||||
| `3072` | C0 maps to coil 3072 (DL260 layout) |
|
||||
| `4000..4007` | Scratch C-relay range for write-roundtrip tests |
|
||||
|
||||
The DL260 X-input markers (FC02 discrete inputs) **are not encoded separately**
|
||||
because the profile uses `shared blocks: true` (matches DL series memory
|
||||
model) — coils/DI/HR/IR overlay the same word address space. Tests that
|
||||
target FC02 against this profile end up reading the same bit positions as
|
||||
the coils they share with.
|
||||
|
||||
## What's IN pymodbus that wasn't in ModbusPal
|
||||
|
||||
- **All four standard tables** (HR, IR, coils, DI) configurable via `co size` / `di size` / `hr size` / `ir size` setup keys.
|
||||
- **Per-register raw uint16 seeding** — `{"addr": 1040, "value": 25928}` puts exactly that 16-bit value on the wire. No interpretation.
|
||||
- **Built-in actions**: `increment`, `random`, `timestamp`, `reset`, `uptime` for declarative dynamic registers. No Python script alongside the config required.
|
||||
- **Custom actions** — point `--custom_actions_module` at a `.py` file exposing callables to express anything more complex (per-second wall-clock ticks, BCD synthesis, etc.).
|
||||
- **Headless** — pure CLI process, no Java, no Swing. Pip-installable. Plays well with CI runners.
|
||||
- **Web UI / REST API** — `--http_port 8080` adds an aiohttp server for live inspection. Optional.
|
||||
- **Maintained** — current stable 3.13.0 (April 2026), active development on 4.0 dev branch.
|
||||
|
||||
## Trade-offs vs the hand-authored ModbusPal profiles
|
||||
|
||||
- pymodbus's built-in `float32` type stores in pymodbus's word order; for explicit DL205 CDAB control we seed two raw `uint16` entries instead. Documented inline in `dl205.json`.
|
||||
- `increment` action ticks per-access, not wall-clock. A 250ms-poll integration test sees variation either way; for strict 1Hz cadence add `--custom_actions_module my_actions.py` with a `time.time()`-based callable.
|
||||
- `dl205.json` uses `shared blocks: true` because it matches DL series memory model; `standard.json` uses `shared blocks: false` so coils and HR address spaces are independent (more like a textbook PLC).
|
||||
|
||||
## File format reference
|
||||
|
||||
```json
|
||||
{
|
||||
"server_list": {
|
||||
"<server-name>": {
|
||||
"comm": "tcp",
|
||||
"host": "0.0.0.0",
|
||||
"port": 5020,
|
||||
"framer": "socket",
|
||||
"device_id": 1
|
||||
}
|
||||
},
|
||||
"device_list": {
|
||||
"<device-name>": {
|
||||
"setup": {
|
||||
"co size": N, "di size": N, "hr size": N, "ir size": N,
|
||||
"shared blocks": false,
|
||||
"type exception": false,
|
||||
"defaults": { "value": {...}, "action": {...} }
|
||||
},
|
||||
"invalid": [],
|
||||
"write": [[<from>, <to>]],
|
||||
"bits": [{"addr": N, "value": 0|1}],
|
||||
"uint16": [{"addr": N, "value": <0..65535>, "action"?: "increment", "parameters"?: {...}}],
|
||||
"uint32": [{"addr": N, "value": <int>}],
|
||||
"float32": [{"addr": N, "value": <float>}],
|
||||
"string": [{"addr": N, "value": "<text>"}],
|
||||
"repeat": []
|
||||
}
|
||||
}
|
||||
}
|
||||
```
|
||||
|
||||
The CLI args `--modbus_server <server-name> --modbus_device <device-name>`
|
||||
pick which entries the simulator binds.
|
||||
|
||||
## References
|
||||
|
||||
- [pymodbus on PyPI](https://pypi.org/project/pymodbus/) — install, version pin
|
||||
- [Simulator config docs](https://pymodbus.readthedocs.io/en/dev/source/library/simulator/config.html) — full schema reference
|
||||
- [Simulator REST API](https://pymodbus.readthedocs.io/en/latest/source/library/simulator/restapi.html) — for the optional web UI
|
||||
- [`docs/v2/dl205.md`](../../../docs/v2/dl205.md) — what each DL205 profile entry simulates
|
||||
- [`docs/v2/modbus-test-plan.md`](../../../docs/v2/modbus-test-plan.md) — the `DL205_<behavior>` test naming convention
|
||||
@@ -0,0 +1,111 @@
|
||||
{
|
||||
"_comment": "DL205.json — DirectLOGIC DL205/DL260 quirk simulator. Models docs/v2/dl205.md as concrete register values. NOTE: pymodbus rejects unknown keys at device-list / setup level; explanatory comments live at top-level _comment + in README + git. Inline _quirk keys WITHIN individual register entries are accepted by pymodbus 3.13.0 (it only validates addr / value / action / parameters per entry). Each quirky uint16 is a pre-computed raw 16-bit value; pymodbus serves it verbatim. shared blocks=true matches DL series memory model. write list mirrors each seeded block — pymodbus rejects sweeping write ranges that include undefined cells.",
|
||||
|
||||
"server_list": {
|
||||
"srv": {
|
||||
"comm": "tcp",
|
||||
"host": "0.0.0.0",
|
||||
"port": 5020,
|
||||
"framer": "socket",
|
||||
"device_id": 1
|
||||
}
|
||||
},
|
||||
|
||||
"device_list": {
|
||||
"dev": {
|
||||
"setup": {
|
||||
"co size": 16384,
|
||||
"di size": 8192,
|
||||
"hr size": 16384,
|
||||
"ir size": 1024,
|
||||
"shared blocks": true,
|
||||
"type exception": false,
|
||||
"defaults": {
|
||||
"value": {"bits": 0, "uint16": 0, "uint32": 0, "float32": 0.0, "string": " "},
|
||||
"action": {"bits": null, "uint16": null, "uint32": null, "float32": null, "string": null}
|
||||
}
|
||||
},
|
||||
"invalid": [],
|
||||
"write": [
|
||||
[0, 0],
|
||||
[200, 209],
|
||||
[1024, 1024],
|
||||
[1040, 1042],
|
||||
[1056, 1057],
|
||||
[1072, 1072],
|
||||
[1280, 1282],
|
||||
[1343, 1343],
|
||||
[1407, 1407],
|
||||
[1, 1],
|
||||
[128, 128],
|
||||
[192, 192],
|
||||
[250, 250],
|
||||
[8448, 8448]
|
||||
],
|
||||
|
||||
"uint16": [
|
||||
{"_quirk": "V0 marker. HR[0]=0xCAFE proves register 0 is valid on DL205/DL260 (rejects-register-0 was a DL05/DL06 relative-mode artefact). 0xCAFE = 51966.",
|
||||
"addr": 0, "value": 51966},
|
||||
|
||||
{"_quirk": "Scratch HR range 200..209 — mirrors the standard.json scratch range so the smoke test (DL205Profile.SmokeHoldingRegister=200) round-trips identically against either profile.",
|
||||
"addr": 200, "value": 0},
|
||||
{"addr": 201, "value": 0},
|
||||
{"addr": 202, "value": 0},
|
||||
{"addr": 203, "value": 0},
|
||||
{"addr": 204, "value": 0},
|
||||
{"addr": 205, "value": 0},
|
||||
{"addr": 206, "value": 0},
|
||||
{"addr": 207, "value": 0},
|
||||
{"addr": 208, "value": 0},
|
||||
{"addr": 209, "value": 0},
|
||||
|
||||
{"_quirk": "V2000 marker. V2000 octal = decimal 1024 = PDU 0x0400. Marker 0x2000 = 8192.",
|
||||
"addr": 1024, "value": 8192},
|
||||
|
||||
{"_quirk": "V40400 marker. V40400 octal = decimal 8448 = PDU 0x2100 (NOT register 0). Marker 0x4040 = 16448.",
|
||||
"addr": 8448, "value": 16448},
|
||||
|
||||
{"_quirk": "String 'Hello' first char in LOW byte. HR[0x410] = 'H'(0x48) lo + 'e'(0x65) hi = 0x6548 = 25928.",
|
||||
"addr": 1040, "value": 25928},
|
||||
{"_quirk": "String 'Hello' second char-pair: 'l'(0x6C) lo + 'l'(0x6C) hi = 0x6C6C = 27756.",
|
||||
"addr": 1041, "value": 27756},
|
||||
{"_quirk": "String 'Hello' third char-pair: 'o'(0x6F) lo + null(0x00) hi = 0x006F = 111.",
|
||||
"addr": 1042, "value": 111},
|
||||
|
||||
{"_quirk": "Float32 1.5f in CDAB word order. IEEE 754 1.5 = 0x3FC00000. CDAB = low word first: HR[0x420]=0x0000, HR[0x421]=0x3FC0=16320.",
|
||||
"addr": 1056, "value": 0},
|
||||
{"_quirk": "Float32 1.5f CDAB high word.",
|
||||
"addr": 1057, "value": 16320},
|
||||
|
||||
{"_quirk": "BCD register. Decimal 1234 stored as BCD nibbles 0x1234 = 4660. NOT binary 1234 (= 0x04D2).",
|
||||
"addr": 1072, "value": 4660},
|
||||
|
||||
{"_quirk": "FC03 cap test marker — first cell of a 128-register span the FC03 cap test reads. Other cells in the span aren't seeded explicitly, so reads of HR[1283..1342] / 1344..1406 return the default 0; the seeded markers at 1280, 1281, 1282, 1343, 1407 prove the span boundaries.",
|
||||
"addr": 1280, "value": 0},
|
||||
{"addr": 1281, "value": 1},
|
||||
{"addr": 1282, "value": 2},
|
||||
{"addr": 1343, "value": 63},
|
||||
{"addr": 1407, "value": 127}
|
||||
],
|
||||
|
||||
"bits": [
|
||||
{"_quirk": "X-input bank marker cell. X0 -> DI 0 conflicts with uint16 V0 at cell 0, so this marker covers X20 octal (= decimal 16 = DI 16 = cell 1 bit 0). X20=ON, X23 octal (DI 19 = cell 1 bit 3)=ON -> cell 1 value = 0b00001001 = 9.",
|
||||
"addr": 1, "value": 9},
|
||||
|
||||
{"_quirk": "Y-output bank marker cell. pymodbus's simulator maps Modbus FC01/02/05 bit-addresses to cell index = bit_addr / 16; so Modbus coil 2048 lives at cell 128 bit 0. Y0=ON (bit 0), Y1=OFF (bit 1), Y2=ON (bit 2) -> value=0b00000101=5 proves DL260 mapping Y0 -> coil 2048.",
|
||||
"addr": 128, "value": 5},
|
||||
|
||||
{"_quirk": "C-relay bank marker cell. Modbus coil 3072 -> cell 192 bit 0. C0=ON (bit 0), C1=OFF (bit 1), C2=ON (bit 2) -> value=5 proves DL260 mapping C0 -> coil 3072.",
|
||||
"addr": 192, "value": 5},
|
||||
|
||||
{"_quirk": "Scratch cell for coil 4000..4015 write round-trip tests. Cell 250 holds Modbus coils 4000-4015; all bits start at 0 and tests set specific bits via FC05.",
|
||||
"addr": 250, "value": 0}
|
||||
],
|
||||
|
||||
"uint32": [],
|
||||
"float32": [],
|
||||
"string": [],
|
||||
"repeat": []
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -0,0 +1,60 @@
|
||||
<#
|
||||
.SYNOPSIS
|
||||
Launches the pymodbus simulator with one of the integration-test profiles
|
||||
(Standard or DL205). Foreground process — Ctrl+C to stop.
|
||||
|
||||
.PARAMETER Profile
|
||||
Which simulator profile to run: 'standard' or 'dl205'. Both bind TCP 5020 by
|
||||
default so they can't run simultaneously on the same box.
|
||||
|
||||
.PARAMETER HttpPort
|
||||
Port for pymodbus's optional web UI / REST API. Default 8080. Pass 0 to
|
||||
disable (passes --no_http).
|
||||
|
||||
.EXAMPLE
|
||||
.\serve.ps1 -Profile standard
|
||||
Starts the standard server on TCP 5020 with web UI on 8080.
|
||||
|
||||
.EXAMPLE
|
||||
.\serve.ps1 -Profile dl205 -HttpPort 0
|
||||
Starts the DL205 server on TCP 5020, no web UI.
|
||||
#>
|
||||
[CmdletBinding()]
|
||||
param(
|
||||
[Parameter(Mandatory)] [ValidateSet('standard', 'dl205')] [string]$Profile,
|
||||
[int]$HttpPort = 8080
|
||||
)
|
||||
|
||||
$ErrorActionPreference = 'Stop'
|
||||
$here = $PSScriptRoot
|
||||
|
||||
# Confirm pymodbus.simulator is on PATH — clearer message than the
|
||||
# 'CommandNotFoundException' dotnet style.
|
||||
$cmd = Get-Command pymodbus.simulator -ErrorAction SilentlyContinue
|
||||
if (-not $cmd) {
|
||||
Write-Error "pymodbus.simulator not found. Install with: pip install 'pymodbus[simulator]==3.13.0'"
|
||||
exit 1
|
||||
}
|
||||
|
||||
$jsonFile = Join-Path $here "$Profile.json"
|
||||
if (-not (Test-Path $jsonFile)) {
|
||||
Write-Error "Profile config not found: $jsonFile"
|
||||
exit 1
|
||||
}
|
||||
|
||||
$args = @(
|
||||
'--modbus_server', 'srv',
|
||||
'--modbus_device', 'dev',
|
||||
'--json_file', $jsonFile
|
||||
)
|
||||
|
||||
if ($HttpPort -gt 0) {
|
||||
$args += @('--http_port', $HttpPort)
|
||||
Write-Host "Web UI will be at http://localhost:$HttpPort"
|
||||
} else {
|
||||
$args += '--no_http'
|
||||
}
|
||||
|
||||
Write-Host "Starting pymodbus simulator: profile=$Profile TCP=localhost:5020"
|
||||
Write-Host "Ctrl+C to stop."
|
||||
& pymodbus.simulator @args
|
||||
@@ -0,0 +1,97 @@
|
||||
{
|
||||
"_comment": "Standard.json — generic Modbus TCP server for the integration suite. See ../README.md. NOTE: pymodbus rejects unknown keys at device-list / setup level; explanatory comments live in the README + git history. Layout: HR[0..31]=address-as-value, HR[100]=auto-increment, HR[200..209]=scratch, coils 1024..1055=alternating, coils 1100..1109=scratch. Coils live at 1024+ because pymodbus stores all 4 standard tables in ONE underlying cell array — bits and uint16 at the same address conflict (each cell can only be typed once).",
|
||||
|
||||
"server_list": {
|
||||
"srv": {
|
||||
"comm": "tcp",
|
||||
"host": "0.0.0.0",
|
||||
"port": 5020,
|
||||
"framer": "socket",
|
||||
"device_id": 1
|
||||
}
|
||||
},
|
||||
|
||||
"device_list": {
|
||||
"dev": {
|
||||
"setup": {
|
||||
"co size": 2048,
|
||||
"di size": 2048,
|
||||
"hr size": 2048,
|
||||
"ir size": 2048,
|
||||
"shared blocks": true,
|
||||
"type exception": false,
|
||||
"defaults": {
|
||||
"value": {"bits": 0, "uint16": 0, "uint32": 0, "float32": 0.0, "string": " "},
|
||||
"action": {"bits": null, "uint16": null, "uint32": null, "float32": null, "string": null}
|
||||
}
|
||||
},
|
||||
"invalid": [],
|
||||
"write": [
|
||||
[0, 31],
|
||||
[100, 100],
|
||||
[200, 209],
|
||||
[1024, 1055],
|
||||
[1100, 1109]
|
||||
],
|
||||
|
||||
"uint16": [
|
||||
{"addr": 0, "value": 0}, {"addr": 1, "value": 1},
|
||||
{"addr": 2, "value": 2}, {"addr": 3, "value": 3},
|
||||
{"addr": 4, "value": 4}, {"addr": 5, "value": 5},
|
||||
{"addr": 6, "value": 6}, {"addr": 7, "value": 7},
|
||||
{"addr": 8, "value": 8}, {"addr": 9, "value": 9},
|
||||
{"addr": 10, "value": 10}, {"addr": 11, "value": 11},
|
||||
{"addr": 12, "value": 12}, {"addr": 13, "value": 13},
|
||||
{"addr": 14, "value": 14}, {"addr": 15, "value": 15},
|
||||
{"addr": 16, "value": 16}, {"addr": 17, "value": 17},
|
||||
{"addr": 18, "value": 18}, {"addr": 19, "value": 19},
|
||||
{"addr": 20, "value": 20}, {"addr": 21, "value": 21},
|
||||
{"addr": 22, "value": 22}, {"addr": 23, "value": 23},
|
||||
{"addr": 24, "value": 24}, {"addr": 25, "value": 25},
|
||||
{"addr": 26, "value": 26}, {"addr": 27, "value": 27},
|
||||
{"addr": 28, "value": 28}, {"addr": 29, "value": 29},
|
||||
{"addr": 30, "value": 30}, {"addr": 31, "value": 31},
|
||||
|
||||
{"addr": 100, "value": 0,
|
||||
"action": "increment",
|
||||
"parameters": {"minval": 0, "maxval": 65535}},
|
||||
|
||||
{"addr": 200, "value": 0}, {"addr": 201, "value": 0},
|
||||
{"addr": 202, "value": 0}, {"addr": 203, "value": 0},
|
||||
{"addr": 204, "value": 0}, {"addr": 205, "value": 0},
|
||||
{"addr": 206, "value": 0}, {"addr": 207, "value": 0},
|
||||
{"addr": 208, "value": 0}, {"addr": 209, "value": 0}
|
||||
],
|
||||
|
||||
"bits": [
|
||||
{"addr": 1024, "value": 1}, {"addr": 1025, "value": 0},
|
||||
{"addr": 1026, "value": 1}, {"addr": 1027, "value": 0},
|
||||
{"addr": 1028, "value": 1}, {"addr": 1029, "value": 0},
|
||||
{"addr": 1030, "value": 1}, {"addr": 1031, "value": 0},
|
||||
{"addr": 1032, "value": 1}, {"addr": 1033, "value": 0},
|
||||
{"addr": 1034, "value": 1}, {"addr": 1035, "value": 0},
|
||||
{"addr": 1036, "value": 1}, {"addr": 1037, "value": 0},
|
||||
{"addr": 1038, "value": 1}, {"addr": 1039, "value": 0},
|
||||
{"addr": 1040, "value": 1}, {"addr": 1041, "value": 0},
|
||||
{"addr": 1042, "value": 1}, {"addr": 1043, "value": 0},
|
||||
{"addr": 1044, "value": 1}, {"addr": 1045, "value": 0},
|
||||
{"addr": 1046, "value": 1}, {"addr": 1047, "value": 0},
|
||||
{"addr": 1048, "value": 1}, {"addr": 1049, "value": 0},
|
||||
{"addr": 1050, "value": 1}, {"addr": 1051, "value": 0},
|
||||
{"addr": 1052, "value": 1}, {"addr": 1053, "value": 0},
|
||||
{"addr": 1054, "value": 1}, {"addr": 1055, "value": 0},
|
||||
|
||||
{"addr": 1100, "value": 0}, {"addr": 1101, "value": 0},
|
||||
{"addr": 1102, "value": 0}, {"addr": 1103, "value": 0},
|
||||
{"addr": 1104, "value": 0}, {"addr": 1105, "value": 0},
|
||||
{"addr": 1106, "value": 0}, {"addr": 1107, "value": 0},
|
||||
{"addr": 1108, "value": 0}, {"addr": 1109, "value": 0}
|
||||
],
|
||||
|
||||
"uint32": [],
|
||||
"float32": [],
|
||||
"string": [],
|
||||
"repeat": []
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -24,7 +24,7 @@
|
||||
</ItemGroup>
|
||||
|
||||
<ItemGroup>
|
||||
<None Update="ModbusPal\**\*" CopyToOutputDirectory="PreserveNewest"/>
|
||||
<None Update="Pymodbus\**\*" CopyToOutputDirectory="PreserveNewest"/>
|
||||
<None Update="DL205\**\*" CopyToOutputDirectory="PreserveNewest"/>
|
||||
</ItemGroup>
|
||||
|
||||
|
||||
@@ -0,0 +1,139 @@
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests;
|
||||
|
||||
[Trait("Category", "Unit")]
|
||||
public sealed class DirectLogicAddressTests
|
||||
{
|
||||
[Theory]
|
||||
[InlineData("V0", (ushort)0x0000)]
|
||||
[InlineData("V1", (ushort)0x0001)]
|
||||
[InlineData("V7", (ushort)0x0007)]
|
||||
[InlineData("V10", (ushort)0x0008)]
|
||||
[InlineData("V2000", (ushort)0x0400)] // canonical DL205/DL260 user-memory start
|
||||
[InlineData("V7777", (ushort)0x0FFF)]
|
||||
[InlineData("V10000", (ushort)0x1000)]
|
||||
[InlineData("V17777", (ushort)0x1FFF)]
|
||||
public void UserVMemoryToPdu_converts_octal_V_prefix(string v, ushort expected)
|
||||
=> DirectLogicAddress.UserVMemoryToPdu(v).ShouldBe(expected);
|
||||
|
||||
[Theory]
|
||||
[InlineData("0", (ushort)0)]
|
||||
[InlineData("2000", (ushort)0x0400)]
|
||||
[InlineData("v2000", (ushort)0x0400)] // lowercase v
|
||||
[InlineData(" V2000 ", (ushort)0x0400)] // surrounding whitespace
|
||||
public void UserVMemoryToPdu_accepts_bare_or_prefixed_or_padded(string v, ushort expected)
|
||||
=> DirectLogicAddress.UserVMemoryToPdu(v).ShouldBe(expected);
|
||||
|
||||
[Theory]
|
||||
[InlineData("V8")] // 8 is not a valid octal digit
|
||||
[InlineData("V19")]
|
||||
[InlineData("V2009")]
|
||||
public void UserVMemoryToPdu_rejects_non_octal_digits(string v)
|
||||
{
|
||||
Should.Throw<ArgumentException>(() => DirectLogicAddress.UserVMemoryToPdu(v))
|
||||
.Message.ShouldContain("octal");
|
||||
}
|
||||
|
||||
[Theory]
|
||||
[InlineData(null)]
|
||||
[InlineData("")]
|
||||
[InlineData(" ")]
|
||||
[InlineData("V")]
|
||||
public void UserVMemoryToPdu_rejects_empty_input(string? v)
|
||||
=> Should.Throw<ArgumentException>(() => DirectLogicAddress.UserVMemoryToPdu(v!));
|
||||
|
||||
[Fact]
|
||||
public void UserVMemoryToPdu_overflow_rejected()
|
||||
{
|
||||
// 200000 octal = 0x10000 — one past ushort range.
|
||||
Should.Throw<OverflowException>(() => DirectLogicAddress.UserVMemoryToPdu("V200000"));
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void SystemVMemoryBasePdu_is_0x2100_for_V40400()
|
||||
{
|
||||
// V40400 on DL260 / H2-ECOM100 absolute mode → PDU 0x2100 (decimal 8448), NOT 0x4100
|
||||
// which a naive octal-to-decimal of 40400 octal would give (= 16640).
|
||||
DirectLogicAddress.SystemVMemoryBasePdu.ShouldBe((ushort)0x2100);
|
||||
DirectLogicAddress.SystemVMemoryToPdu(0).ShouldBe((ushort)0x2100);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void SystemVMemoryToPdu_offsets_within_bank()
|
||||
{
|
||||
DirectLogicAddress.SystemVMemoryToPdu(1).ShouldBe((ushort)0x2101);
|
||||
DirectLogicAddress.SystemVMemoryToPdu(0x100).ShouldBe((ushort)0x2200);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void SystemVMemoryToPdu_rejects_overflow()
|
||||
{
|
||||
// ushort wrap: 0xFFFF - 0x2100 = 0xDEFF; anything above should throw.
|
||||
Should.NotThrow(() => DirectLogicAddress.SystemVMemoryToPdu(0xDEFF));
|
||||
Should.Throw<OverflowException>(() => DirectLogicAddress.SystemVMemoryToPdu(0xDF00));
|
||||
}
|
||||
|
||||
// --- Bit memory: Y-output, C-relay, X-input, SP-special ---
|
||||
|
||||
[Theory]
|
||||
[InlineData("Y0", (ushort)2048)]
|
||||
[InlineData("Y1", (ushort)2049)]
|
||||
[InlineData("Y7", (ushort)2055)]
|
||||
[InlineData("Y10", (ushort)2056)] // octal 10 = decimal 8
|
||||
[InlineData("Y17", (ushort)2063)] // octal 17 = decimal 15
|
||||
[InlineData("Y777", (ushort)2559)] // top of DL260 Y range per doc table
|
||||
public void YOutputToCoil_adds_octal_offset_to_2048(string y, ushort expected)
|
||||
=> DirectLogicAddress.YOutputToCoil(y).ShouldBe(expected);
|
||||
|
||||
[Theory]
|
||||
[InlineData("C0", (ushort)3072)]
|
||||
[InlineData("C1", (ushort)3073)]
|
||||
[InlineData("C10", (ushort)3080)]
|
||||
[InlineData("C1777", (ushort)4095)] // top of DL260 C range
|
||||
public void CRelayToCoil_adds_octal_offset_to_3072(string c, ushort expected)
|
||||
=> DirectLogicAddress.CRelayToCoil(c).ShouldBe(expected);
|
||||
|
||||
[Theory]
|
||||
[InlineData("X0", (ushort)0)]
|
||||
[InlineData("X17", (ushort)15)]
|
||||
[InlineData("X777", (ushort)511)] // top of DL260 X range
|
||||
public void XInputToDiscrete_adds_octal_offset_to_0(string x, ushort expected)
|
||||
=> DirectLogicAddress.XInputToDiscrete(x).ShouldBe(expected);
|
||||
|
||||
[Theory]
|
||||
[InlineData("SP0", (ushort)1024)]
|
||||
[InlineData("SP7", (ushort)1031)]
|
||||
[InlineData("sp0", (ushort)1024)] // lowercase prefix
|
||||
[InlineData("SP777", (ushort)1535)]
|
||||
public void SpecialToDiscrete_adds_octal_offset_to_1024(string sp, ushort expected)
|
||||
=> DirectLogicAddress.SpecialToDiscrete(sp).ShouldBe(expected);
|
||||
|
||||
[Theory]
|
||||
[InlineData("Y8")]
|
||||
[InlineData("C9")]
|
||||
[InlineData("X18")]
|
||||
public void Bit_address_rejects_non_octal_digits(string bad)
|
||||
=> Should.Throw<ArgumentException>(() =>
|
||||
{
|
||||
if (bad[0] == 'Y') DirectLogicAddress.YOutputToCoil(bad);
|
||||
else if (bad[0] == 'C') DirectLogicAddress.CRelayToCoil(bad);
|
||||
else DirectLogicAddress.XInputToDiscrete(bad);
|
||||
});
|
||||
|
||||
[Theory]
|
||||
[InlineData("Y")]
|
||||
[InlineData("C")]
|
||||
[InlineData("")]
|
||||
public void Bit_address_rejects_empty(string bad)
|
||||
=> Should.Throw<ArgumentException>(() => DirectLogicAddress.YOutputToCoil(bad));
|
||||
|
||||
[Fact]
|
||||
public void YOutputToCoil_accepts_lowercase_prefix()
|
||||
=> DirectLogicAddress.YOutputToCoil("y0").ShouldBe((ushort)2048);
|
||||
|
||||
[Fact]
|
||||
public void CRelayToCoil_accepts_bare_octal_without_C_prefix()
|
||||
=> DirectLogicAddress.CRelayToCoil("0").ShouldBe((ushort)3072);
|
||||
}
|
||||
165
tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests/ModbusCapTests.cs
Normal file
165
tests/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests/ModbusCapTests.cs
Normal file
@@ -0,0 +1,165 @@
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests;
|
||||
|
||||
[Trait("Category", "Unit")]
|
||||
public sealed class ModbusCapTests
|
||||
{
|
||||
/// <summary>
|
||||
/// Records every PDU sent so tests can assert request-count and per-request quantity —
|
||||
/// the only observable behaviour of the auto-chunking path.
|
||||
/// </summary>
|
||||
private sealed class RecordingTransport : IModbusTransport
|
||||
{
|
||||
public readonly ushort[] HoldingRegisters = new ushort[1024];
|
||||
public readonly List<(ushort Address, ushort Quantity)> Fc03Requests = new();
|
||||
public readonly List<(ushort Address, ushort Quantity)> Fc16Requests = new();
|
||||
|
||||
public Task ConnectAsync(CancellationToken ct) => Task.CompletedTask;
|
||||
|
||||
public Task<byte[]> SendAsync(byte unitId, byte[] pdu, CancellationToken ct)
|
||||
{
|
||||
var fc = pdu[0];
|
||||
if (fc == 0x03)
|
||||
{
|
||||
var addr = (ushort)((pdu[1] << 8) | pdu[2]);
|
||||
var qty = (ushort)((pdu[3] << 8) | pdu[4]);
|
||||
Fc03Requests.Add((addr, qty));
|
||||
var byteCount = (byte)(qty * 2);
|
||||
var resp = new byte[2 + byteCount];
|
||||
resp[0] = 0x03;
|
||||
resp[1] = byteCount;
|
||||
for (var i = 0; i < qty; i++)
|
||||
{
|
||||
resp[2 + i * 2] = (byte)(HoldingRegisters[addr + i] >> 8);
|
||||
resp[3 + i * 2] = (byte)(HoldingRegisters[addr + i] & 0xFF);
|
||||
}
|
||||
return Task.FromResult(resp);
|
||||
}
|
||||
if (fc == 0x10)
|
||||
{
|
||||
var addr = (ushort)((pdu[1] << 8) | pdu[2]);
|
||||
var qty = (ushort)((pdu[3] << 8) | pdu[4]);
|
||||
Fc16Requests.Add((addr, qty));
|
||||
for (var i = 0; i < qty; i++)
|
||||
HoldingRegisters[addr + i] = (ushort)((pdu[6 + i * 2] << 8) | pdu[7 + i * 2]);
|
||||
return Task.FromResult(new byte[] { 0x10, pdu[1], pdu[2], pdu[3], pdu[4] });
|
||||
}
|
||||
return Task.FromException<byte[]>(new ModbusException(fc, 0x01, $"fc={fc} unsupported"));
|
||||
}
|
||||
|
||||
public ValueTask DisposeAsync() => ValueTask.CompletedTask;
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task Read_within_cap_issues_single_FC03_request()
|
||||
{
|
||||
var tag = new ModbusTagDefinition("S", ModbusRegion.HoldingRegisters, 0, ModbusDataType.String,
|
||||
StringLength: 40); // 20 regs — fits in default cap (125).
|
||||
var transport = new RecordingTransport();
|
||||
var opts = new ModbusDriverOptions { Host = "fake", Tags = [tag], Probe = new ModbusProbeOptions { Enabled = false } };
|
||||
await using var drv = new ModbusDriver(opts, "modbus-1", _ => transport);
|
||||
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
|
||||
_ = await drv.ReadAsync(["S"], TestContext.Current.CancellationToken);
|
||||
|
||||
transport.Fc03Requests.Count.ShouldBe(1);
|
||||
transport.Fc03Requests[0].Quantity.ShouldBe((ushort)20);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task Read_above_cap_splits_into_two_FC03_requests()
|
||||
{
|
||||
// 240-char string = 120 regs. Cap = 100 (a typical sub-spec device cap). Expect 100 + 20.
|
||||
var tag = new ModbusTagDefinition("LongString", ModbusRegion.HoldingRegisters, 100, ModbusDataType.String,
|
||||
StringLength: 240);
|
||||
var transport = new RecordingTransport();
|
||||
// Seed cells so the re-assembled payload is stable — confirms chunks are stitched in order.
|
||||
for (ushort i = 100; i < 100 + 120; i++)
|
||||
transport.HoldingRegisters[i] = (ushort)((('A' + (i - 100) % 26) << 8) | ('A' + (i - 100) % 26));
|
||||
|
||||
var opts = new ModbusDriverOptions
|
||||
{
|
||||
Host = "fake",
|
||||
Tags = [tag],
|
||||
MaxRegistersPerRead = 100,
|
||||
Probe = new ModbusProbeOptions { Enabled = false },
|
||||
};
|
||||
await using var drv = new ModbusDriver(opts, "modbus-1", _ => transport);
|
||||
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
|
||||
var results = await drv.ReadAsync(["LongString"], TestContext.Current.CancellationToken);
|
||||
results[0].StatusCode.ShouldBe(0u);
|
||||
|
||||
transport.Fc03Requests.Count.ShouldBe(2, "120 regs / cap 100 → 2 requests");
|
||||
transport.Fc03Requests[0].ShouldBe(((ushort)100, (ushort)100));
|
||||
transport.Fc03Requests[1].ShouldBe(((ushort)200, (ushort)20));
|
||||
|
||||
// Payload continuity: re-assembled string starts where register 100 does and keeps going.
|
||||
var s = (string)results[0].Value!;
|
||||
s.Length.ShouldBeGreaterThan(0);
|
||||
s[0].ShouldBe('A'); // register[100] high byte
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task Read_cap_honors_Mitsubishi_lower_cap_of_64()
|
||||
{
|
||||
// 200-char string = 100 regs. Mitsubishi Q cap = 64. Expect: 64, 36.
|
||||
var tag = new ModbusTagDefinition("MitString", ModbusRegion.HoldingRegisters, 0, ModbusDataType.String,
|
||||
StringLength: 200);
|
||||
var transport = new RecordingTransport();
|
||||
var opts = new ModbusDriverOptions { Host = "fake", Tags = [tag], MaxRegistersPerRead = 64, Probe = new ModbusProbeOptions { Enabled = false } };
|
||||
await using var drv = new ModbusDriver(opts, "modbus-1", _ => transport);
|
||||
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
|
||||
_ = await drv.ReadAsync(["MitString"], TestContext.Current.CancellationToken);
|
||||
|
||||
transport.Fc03Requests.Count.ShouldBe(2);
|
||||
transport.Fc03Requests[0].Quantity.ShouldBe((ushort)64);
|
||||
transport.Fc03Requests[1].Quantity.ShouldBe((ushort)36);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task Write_exceeding_cap_throws_instead_of_splitting()
|
||||
{
|
||||
// Partial FC16 across two transactions is not atomic. Forcing an explicit exception so the
|
||||
// caller knows their tag definition is incompatible with the device cap rather than silently
|
||||
// writing half a string and crashing between chunks.
|
||||
var tag = new ModbusTagDefinition("LongStringWrite", ModbusRegion.HoldingRegisters, 0, ModbusDataType.String,
|
||||
StringLength: 220); // 110 regs.
|
||||
var transport = new RecordingTransport();
|
||||
var opts = new ModbusDriverOptions { Host = "fake", Tags = [tag], MaxRegistersPerWrite = 100, Probe = new ModbusProbeOptions { Enabled = false } };
|
||||
await using var drv = new ModbusDriver(opts, "modbus-1", _ => transport);
|
||||
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
|
||||
var results = await drv.WriteAsync(
|
||||
[new WriteRequest("LongStringWrite", new string('A', 220))],
|
||||
TestContext.Current.CancellationToken);
|
||||
|
||||
// Driver catches the internal exception and surfaces BadInternalError — the Fc16Requests
|
||||
// list must still be empty because nothing was sent.
|
||||
results[0].StatusCode.ShouldNotBe(0u);
|
||||
transport.Fc16Requests.Count.ShouldBe(0);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task Write_within_cap_proceeds_normally()
|
||||
{
|
||||
var tag = new ModbusTagDefinition("ShortStringWrite", ModbusRegion.HoldingRegisters, 0, ModbusDataType.String,
|
||||
StringLength: 40); // 20 regs.
|
||||
var transport = new RecordingTransport();
|
||||
var opts = new ModbusDriverOptions { Host = "fake", Tags = [tag], MaxRegistersPerWrite = 100, Probe = new ModbusProbeOptions { Enabled = false } };
|
||||
await using var drv = new ModbusDriver(opts, "modbus-1", _ => transport);
|
||||
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
|
||||
var results = await drv.WriteAsync(
|
||||
[new WriteRequest("ShortStringWrite", "HELLO")],
|
||||
TestContext.Current.CancellationToken);
|
||||
|
||||
results[0].StatusCode.ShouldBe(0u);
|
||||
transport.Fc16Requests.Count.ShouldBe(1);
|
||||
transport.Fc16Requests[0].Quantity.ShouldBe((ushort)20);
|
||||
}
|
||||
}
|
||||
@@ -172,4 +172,144 @@ public sealed class ModbusDataTypeTests
|
||||
wire[1].ShouldBe((byte)'i');
|
||||
for (var i = 2; i < 8; i++) wire[i].ShouldBe((byte)0);
|
||||
}
|
||||
|
||||
// --- DL205 low-byte-first strings (AutomationDirect DirectLOGIC quirk) ---
|
||||
|
||||
[Fact]
|
||||
public void String_LowByteFirst_decodes_DL205_packed_Hello()
|
||||
{
|
||||
// HR[1040] = 0x6548 (wire BE bytes [0x65, 0x48]) decodes first char from low byte = 'H',
|
||||
// second from high byte = 'e'. HR[1041] = 0x6C6C → 'l','l'. HR[1042] = 0x006F → 'o', nul.
|
||||
var tag = new ModbusTagDefinition("T", ModbusRegion.HoldingRegisters, 0, ModbusDataType.String,
|
||||
StringLength: 5, StringByteOrder: ModbusStringByteOrder.LowByteFirst);
|
||||
var wire = new byte[] { 0x65, 0x48, 0x6C, 0x6C, 0x00, 0x6F };
|
||||
ModbusDriver.DecodeRegister(wire, tag).ShouldBe("Hello");
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void String_LowByteFirst_decode_truncates_at_first_nul()
|
||||
{
|
||||
// Low-byte-first with only 2 real chars in register 0 (lo='H', hi='i') and the rest nul.
|
||||
var tag = new ModbusTagDefinition("T", ModbusRegion.HoldingRegisters, 0, ModbusDataType.String,
|
||||
StringLength: 6, StringByteOrder: ModbusStringByteOrder.LowByteFirst);
|
||||
var wire = new byte[] { 0x69, 0x48, 0x00, 0x00, 0x00, 0x00 };
|
||||
ModbusDriver.DecodeRegister(wire, tag).ShouldBe("Hi");
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void String_LowByteFirst_encode_round_trips_with_decode()
|
||||
{
|
||||
var tag = new ModbusTagDefinition("T", ModbusRegion.HoldingRegisters, 0, ModbusDataType.String,
|
||||
StringLength: 5, StringByteOrder: ModbusStringByteOrder.LowByteFirst);
|
||||
var wire = ModbusDriver.EncodeRegister("Hello", tag);
|
||||
// Expect exactly the DL205-documented byte sequence.
|
||||
wire.ShouldBe(new byte[] { 0x65, 0x48, 0x6C, 0x6C, 0x00, 0x6F });
|
||||
ModbusDriver.DecodeRegister(wire, tag).ShouldBe("Hello");
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void String_HighByteFirst_and_LowByteFirst_differ_on_same_wire()
|
||||
{
|
||||
// Same wire buffer, different byte order → first char switches 'H' vs 'e'.
|
||||
var wire = new byte[] { 0x48, 0x65 };
|
||||
var hi = new ModbusTagDefinition("T", ModbusRegion.HoldingRegisters, 0, ModbusDataType.String,
|
||||
StringLength: 2, StringByteOrder: ModbusStringByteOrder.HighByteFirst);
|
||||
var lo = new ModbusTagDefinition("T", ModbusRegion.HoldingRegisters, 0, ModbusDataType.String,
|
||||
StringLength: 2, StringByteOrder: ModbusStringByteOrder.LowByteFirst);
|
||||
ModbusDriver.DecodeRegister(wire, hi).ShouldBe("He");
|
||||
ModbusDriver.DecodeRegister(wire, lo).ShouldBe("eH");
|
||||
}
|
||||
|
||||
// --- BCD (binary-coded decimal, DL205/DL260 default numeric encoding) ---
|
||||
|
||||
[Theory]
|
||||
[InlineData(0x0000u, 0u)]
|
||||
[InlineData(0x0001u, 1u)]
|
||||
[InlineData(0x0009u, 9u)]
|
||||
[InlineData(0x0010u, 10u)]
|
||||
[InlineData(0x1234u, 1234u)]
|
||||
[InlineData(0x9999u, 9999u)]
|
||||
public void DecodeBcd_16_bit_decodes_expected_decimal(uint raw, uint expected)
|
||||
=> ModbusDriver.DecodeBcd(raw, nibbles: 4).ShouldBe(expected);
|
||||
|
||||
[Fact]
|
||||
public void DecodeBcd_rejects_nibbles_above_nine()
|
||||
{
|
||||
Should.Throw<InvalidDataException>(() => ModbusDriver.DecodeBcd(0x00A5u, nibbles: 4))
|
||||
.Message.ShouldContain("Non-BCD nibble");
|
||||
}
|
||||
|
||||
[Theory]
|
||||
[InlineData(0u, 0x0000u)]
|
||||
[InlineData(5u, 0x0005u)]
|
||||
[InlineData(42u, 0x0042u)]
|
||||
[InlineData(1234u, 0x1234u)]
|
||||
[InlineData(9999u, 0x9999u)]
|
||||
public void EncodeBcd_16_bit_encodes_expected_nibbles(uint value, uint expected)
|
||||
=> ModbusDriver.EncodeBcd(value, nibbles: 4).ShouldBe(expected);
|
||||
|
||||
[Fact]
|
||||
public void Bcd16_decodes_DL205_register_1234_as_decimal_1234()
|
||||
{
|
||||
// HR[1072] = 0x1234 on the DL205 profile represents decimal 1234. A plain Int16 decode
|
||||
// would return 0x04D2 = 4660 — proof the BCD path is different.
|
||||
var tag = new ModbusTagDefinition("T", ModbusRegion.HoldingRegisters, 0, ModbusDataType.Bcd16);
|
||||
ModbusDriver.DecodeRegister(new byte[] { 0x12, 0x34 }, tag).ShouldBe(1234);
|
||||
|
||||
var int16Tag = tag with { DataType = ModbusDataType.Int16 };
|
||||
ModbusDriver.DecodeRegister(new byte[] { 0x12, 0x34 }, int16Tag).ShouldBe((short)0x1234);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Bcd16_encode_round_trips_with_decode()
|
||||
{
|
||||
var tag = new ModbusTagDefinition("T", ModbusRegion.HoldingRegisters, 0, ModbusDataType.Bcd16);
|
||||
var wire = ModbusDriver.EncodeRegister(4321, tag);
|
||||
wire.ShouldBe(new byte[] { 0x43, 0x21 });
|
||||
ModbusDriver.DecodeRegister(wire, tag).ShouldBe(4321);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Bcd16_encode_rejects_out_of_range_values()
|
||||
{
|
||||
var tag = new ModbusTagDefinition("T", ModbusRegion.HoldingRegisters, 0, ModbusDataType.Bcd16);
|
||||
Should.Throw<OverflowException>(() => ModbusDriver.EncodeRegister(10000, tag))
|
||||
.Message.ShouldContain("4 decimal digits");
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Bcd32_decodes_8_digits_big_endian()
|
||||
{
|
||||
// 0x12345678 as BCD = decimal 12_345_678.
|
||||
var tag = new ModbusTagDefinition("T", ModbusRegion.HoldingRegisters, 0, ModbusDataType.Bcd32);
|
||||
ModbusDriver.DecodeRegister(new byte[] { 0x12, 0x34, 0x56, 0x78 }, tag).ShouldBe(12_345_678);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Bcd32_word_swap_handles_CDAB_layout()
|
||||
{
|
||||
// PLC stored 12_345_678 with word swap: low-word 0x5678 first, high-word 0x1234 second.
|
||||
// Wire bytes [0x56, 0x78, 0x12, 0x34] + WordSwap → decode to decimal 12_345_678.
|
||||
var tag = new ModbusTagDefinition("T", ModbusRegion.HoldingRegisters, 0, ModbusDataType.Bcd32,
|
||||
ByteOrder: ModbusByteOrder.WordSwap);
|
||||
ModbusDriver.DecodeRegister(new byte[] { 0x56, 0x78, 0x12, 0x34 }, tag).ShouldBe(12_345_678);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Bcd32_encode_round_trips_with_decode()
|
||||
{
|
||||
var tag = new ModbusTagDefinition("T", ModbusRegion.HoldingRegisters, 0, ModbusDataType.Bcd32);
|
||||
var wire = ModbusDriver.EncodeRegister(87_654_321u, tag);
|
||||
wire.ShouldBe(new byte[] { 0x87, 0x65, 0x43, 0x21 });
|
||||
ModbusDriver.DecodeRegister(wire, tag).ShouldBe(87_654_321);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public void Bcd_RegisterCount_matches_underlying_width()
|
||||
{
|
||||
var b16 = new ModbusTagDefinition("A", ModbusRegion.HoldingRegisters, 0, ModbusDataType.Bcd16);
|
||||
var b32 = new ModbusTagDefinition("B", ModbusRegion.HoldingRegisters, 0, ModbusDataType.Bcd32);
|
||||
ModbusDriver.RegisterCount(b16).ShouldBe((ushort)1);
|
||||
ModbusDriver.RegisterCount(b32).ShouldBe((ushort)2);
|
||||
}
|
||||
}
|
||||
|
||||
@@ -0,0 +1,88 @@
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests;
|
||||
|
||||
/// <summary>
|
||||
/// Unit tests for the Modbus-exception-code → OPC UA StatusCode mapping added in PR 52.
|
||||
/// Before PR 52 every server exception + every transport failure collapsed to
|
||||
/// BadInternalError (0x80020000), which made field diagnosis "is this a bad tag or a bad
|
||||
/// driver?" impossible. These tests lock in the translation table documented on
|
||||
/// <see cref="ModbusDriver.MapModbusExceptionToStatus"/>.
|
||||
/// </summary>
|
||||
[Trait("Category", "Unit")]
|
||||
public sealed class ModbusExceptionMapperTests
|
||||
{
|
||||
[Theory]
|
||||
[InlineData((byte)0x01, 0x803D0000u)] // Illegal Function → BadNotSupported
|
||||
[InlineData((byte)0x02, 0x803C0000u)] // Illegal Data Address → BadOutOfRange
|
||||
[InlineData((byte)0x03, 0x803C0000u)] // Illegal Data Value → BadOutOfRange
|
||||
[InlineData((byte)0x04, 0x80550000u)] // Server Failure → BadDeviceFailure
|
||||
[InlineData((byte)0x05, 0x80550000u)] // Acknowledge (long op) → BadDeviceFailure
|
||||
[InlineData((byte)0x06, 0x80550000u)] // Server Busy → BadDeviceFailure
|
||||
[InlineData((byte)0x0A, 0x80050000u)] // Gateway path unavailable → BadCommunicationError
|
||||
[InlineData((byte)0x0B, 0x80050000u)] // Gateway target failed to respond → BadCommunicationError
|
||||
[InlineData((byte)0xFF, 0x80020000u)] // Unknown code → BadInternalError fallback
|
||||
public void MapModbusExceptionToStatus_returns_informative_status(byte code, uint expected)
|
||||
=> ModbusDriver.MapModbusExceptionToStatus(code).ShouldBe(expected);
|
||||
|
||||
private sealed class ExceptionRaisingTransport(byte exceptionCode) : IModbusTransport
|
||||
{
|
||||
public Task ConnectAsync(CancellationToken ct) => Task.CompletedTask;
|
||||
public Task<byte[]> SendAsync(byte unitId, byte[] pdu, CancellationToken ct)
|
||||
=> Task.FromException<byte[]>(new ModbusException(pdu[0], exceptionCode, $"fc={pdu[0]} code={exceptionCode}"));
|
||||
public ValueTask DisposeAsync() => ValueTask.CompletedTask;
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task Read_surface_exception_02_as_BadOutOfRange_not_BadInternalError()
|
||||
{
|
||||
var transport = new ExceptionRaisingTransport(exceptionCode: 0x02);
|
||||
var tag = new ModbusTagDefinition("T", ModbusRegion.HoldingRegisters, 0, ModbusDataType.Int16);
|
||||
var opts = new ModbusDriverOptions { Host = "fake", Tags = [tag], Probe = new ModbusProbeOptions { Enabled = false } };
|
||||
await using var drv = new ModbusDriver(opts, "modbus-1", _ => transport);
|
||||
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
|
||||
var results = await drv.ReadAsync(["T"], TestContext.Current.CancellationToken);
|
||||
results[0].StatusCode.ShouldBe(0x803C0000u, "FC03 at an unmapped register must bubble out as BadOutOfRange so operators can spot a bad tag config");
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task Write_surface_exception_04_as_BadDeviceFailure()
|
||||
{
|
||||
var transport = new ExceptionRaisingTransport(exceptionCode: 0x04);
|
||||
var tag = new ModbusTagDefinition("T", ModbusRegion.HoldingRegisters, 0, ModbusDataType.Int16);
|
||||
var opts = new ModbusDriverOptions { Host = "fake", Tags = [tag], Probe = new ModbusProbeOptions { Enabled = false } };
|
||||
await using var drv = new ModbusDriver(opts, "modbus-1", _ => transport);
|
||||
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
|
||||
var writes = await drv.WriteAsync(
|
||||
[new WriteRequest("T", (short)42)],
|
||||
TestContext.Current.CancellationToken);
|
||||
|
||||
writes[0].StatusCode.ShouldBe(0x80550000u, "FC06 returning exception 04 (CPU in PROGRAM mode) maps to BadDeviceFailure");
|
||||
}
|
||||
|
||||
private sealed class NonModbusFailureTransport : IModbusTransport
|
||||
{
|
||||
public Task ConnectAsync(CancellationToken ct) => Task.CompletedTask;
|
||||
public Task<byte[]> SendAsync(byte unitId, byte[] pdu, CancellationToken ct)
|
||||
=> Task.FromException<byte[]>(new EndOfStreamException("socket closed mid-response"));
|
||||
public ValueTask DisposeAsync() => ValueTask.CompletedTask;
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task Read_non_modbus_failure_maps_to_BadCommunicationError_not_BadInternalError()
|
||||
{
|
||||
// Socket drop / timeout / malformed frame → transport-layer failure. Should surface
|
||||
// distinctly from tag-level faults so operators know to check the network, not the config.
|
||||
var tag = new ModbusTagDefinition("T", ModbusRegion.HoldingRegisters, 0, ModbusDataType.Int16);
|
||||
var opts = new ModbusDriverOptions { Host = "fake", Tags = [tag], Probe = new ModbusProbeOptions { Enabled = false } };
|
||||
await using var drv = new ModbusDriver(opts, "modbus-1", _ => new NonModbusFailureTransport());
|
||||
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
|
||||
var results = await drv.ReadAsync(["T"], TestContext.Current.CancellationToken);
|
||||
results[0].StatusCode.ShouldBe(0x80050000u);
|
||||
}
|
||||
}
|
||||