Standard.xmpp — generic Modbus TCP server on port 502, slave id 1. HR[0..31] seeded with address-as-value (HR[5]=5 — easy mental map for diagnostics), HR[100] auto-incrementing via a 1Hz LinearGenerator binding (drives subscribe-and-receive integration tests so they have a register that actually changes without a write), HR[200..209] scratch range for write-roundtrip tests, coils 0..31 alternating on/off, coils 100..109 scratch. The Tick automation runs 0..65535 over 60s looping; bound to HR[100] via Binding_SINT16 — slow enough that a 250ms-poll integration test sees discrete jumps, fast enough that a 5s subscribe test sees several change notifications. DL205.xmpp — AutomationDirect DirectLOGIC DL205/DL260 quirk simulator on port 502, slave id 1, modeling the behaviors documented in docs/v2/dl205.md as concrete register values so DL205 integration tests can assert each quirk WITHOUT a live PLC. Per-quirk encoding: V0 marker at HR[0]=0xCAFE proves register 0 is valid (rejects-register-0 rumour disproved); V2000 marker at HR[1024]=0x2000 proves V-memory octal-to-decimal mapping; V40400 marker at HR[8448]=0x4040 proves V40400→PDU 0x2100 (NOT register 0, contrary to the widespread shorthand); 'Hello' string at HR[1040..1042] packed first-char-low-byte (HR[1040]=0x6548 = 'H' lo + 'e' hi, HR[1041]=0x6C6C, HR[1042]=0x006F) — the headline string-byte-order quirk the user flagged; Float32 1.5f at HR[1056..1057] in CDAB word order (low word first: 0, then 0x3FC0); BCD register at HR[1072]=0x1234 representing decimal 1234 in BCD nibbles (NOT binary 0x04D2); 128-register block at HR[1280..1407] for FC03-128-cap testing; Y0 marker at coil 2048, C0 marker at coil 3072, scratch C-coils at 4000..4007 for write tests. Critical limitation flagged inline + in README: ModbusPal 1.6b CANNOT represent the DL205 quirks semantically — it has no string binding, no BCD binding, no arbitrary-byte-layout binding (only SINT16/SINT32/FLOAT32 with word-order). So every DL205 quirk is encoded as a pre-computed raw 16-bit integer with the math worked out in inline comments above each register. Becomes unreadable past ~50 quirky registers; the README's 'alternatives' section recommends switching to pymodbus when that threshold approaches (pymodbus's ModbusSimulatorServer has first-class headless + scriptable callbacks for byte-level layouts). Other ModbusPal 1.6b limitations called out in README: only holding_registers + coils sections in the official build (no input_registers / discrete_inputs — DL260 X-input markers can't be encoded faithfully here, FC02/FC04 tests wait for a fork or pymodbus); abandoned project (last release 1.6b, active forks at SCADA-LTS/ModbusPal, ControlThings-io/modbuspal, mrhenrike/ModbusPalEnhanced); no headless mode in the official JAR (-loadFile / -hide flags only in source-built forks); CVE-2018-10832 XXE on .xmpp import (don't import untrusted profiles — the in-repo ones are author-controlled). README.md updated with: per-profile description tables, getting-started (download jar + java -jar + GUI File>Load>Run), MODBUS_SIM_ENDPOINT env-var override doc, two reference tables documenting which HR / coil address encodes which DL205 quirk + which test name asserts it (the same DL205_<behavior> naming convention from docs/v2/modbus-test-plan.md), 4-row alternatives comparison (pymodbus / diagslave / ModbusMechanic / ModRSsim2) for when ModbusPal can no longer carry the load, and a quick-reference XML format table at the bottom for future-me hand-authoring more profiles. Pure documentation + test-asset PR — no code changes. The integration tests that consume these profiles (the actual DL205_<behavior> facts) land one at a time in PR 43+ as user validates each quirk via ModbusPal on the bench. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
LmxOpcUa
OPC UA server and cross-platform client tools for AVEVA System Platform (Wonderware) Galaxy. The server exposes Galaxy tags via MXAccess as an OPC UA address space. The client stack provides a shared library, CLI tool, and Avalonia desktop application for browsing, reading/writing, subscriptions, alarms, and historical data.
Architecture
OPC UA Clients
(CLI, Desktop UI, 3rd-party)
|
v
+-----------------+ +------------------+ +-----------------+
| Galaxy Repo DB |---->| OPC UA Server |<--->| MXAccess Client |
| (SQL Server) | | (address space) | | (STA + COM) |
+-----------------+ +------------------+ +-----------------+
| |
+-------+--------+ +---------+---------+
| Status Dashboard| | Historian Runtime |
| (HTTP/JSON) | | (SQL Server) |
+----------------+ +-------------------+
Contained Name vs Tag Name
| Browse Path (contained names) | Runtime Reference (tag name) |
|---|---|
TestMachine_001/DelmiaReceiver/DownloadPath |
DelmiaReceiver_001.DownloadPath |
TestMachine_001/MESReceiver/MoveInBatchID |
MESReceiver_001.MoveInBatchID |
Server
The OPC UA server runs on .NET Framework 4.8 (x86) and bridges the Galaxy runtime to OPC UA clients.
Server Prerequisites
- .NET Framework 4.8 SDK
- AVEVA System Platform with ArchestrA Framework installed
- Galaxy repository database (SQL Server, Windows Auth)
- MXAccess COM registered (
LMXProxy.LMXProxyServer) - Wonderware Historian (optional, for historical data access)
- Windows (required for COM interop and MXAccess)
Build and Run Server
dotnet restore ZB.MOM.WW.LmxOpcUa.slnx
dotnet build src/ZB.MOM.WW.LmxOpcUa.Host
dotnet run --project src/ZB.MOM.WW.LmxOpcUa.Host
The server starts on opc.tcp://localhost:4840/LmxOpcUa with the None security profile by default. Configure Security.Profiles in appsettings.json to enable Basic256Sha256-Sign or Basic256Sha256-SignAndEncrypt for transport security. See Security Guide.
Install as Windows Service
cd src/ZB.MOM.WW.LmxOpcUa.Host/bin/Debug/net48
ZB.MOM.WW.LmxOpcUa.Host.exe install
ZB.MOM.WW.LmxOpcUa.Host.exe start
Service logon requirement: The service must run under a Windows account that has access to the AVEVA Galaxy and Historian. The default LocalSystem account can connect to MXAccess and SQL Server but cannot authenticate with the Historian SDK (HCAP). Configure the service to "Log on as" a domain or local user that is a recognized ArchestrA platform user. This can be set in services.msc or during install with ZB.MOM.WW.LmxOpcUa.Host.exe install -username DOMAIN\user -password ***.
Run Server Tests
dotnet test tests/ZB.MOM.WW.LmxOpcUa.Tests
dotnet test tests/ZB.MOM.WW.LmxOpcUa.IntegrationTests
Client Stack
The client stack is cross-platform (.NET 10) and consists of three projects sharing a common IOpcUaClientService abstraction. No AVEVA software or COM is required — the clients connect to any OPC UA server.
Client Prerequisites
- .NET 10 SDK
- No platform-specific dependencies (runs on Windows, macOS, Linux)
Build All Clients
dotnet build src/ZB.MOM.WW.LmxOpcUa.Client.Shared
dotnet build src/ZB.MOM.WW.LmxOpcUa.Client.CLI
dotnet build src/ZB.MOM.WW.LmxOpcUa.Client.UI
Run Client Tests
dotnet test tests/ZB.MOM.WW.LmxOpcUa.Client.Shared.Tests
dotnet test tests/ZB.MOM.WW.LmxOpcUa.Client.CLI.Tests
dotnet test tests/ZB.MOM.WW.LmxOpcUa.Client.UI.Tests
Client CLI
# Connect
dotnet run --project src/ZB.MOM.WW.LmxOpcUa.Client.CLI -- connect -u opc.tcp://localhost:4840/LmxOpcUa
# Browse Galaxy hierarchy
dotnet run --project src/ZB.MOM.WW.LmxOpcUa.Client.CLI -- browse -u opc.tcp://localhost:4840/LmxOpcUa -n "ns=3;s=ZB" -r -d 5
# Read a tag
dotnet run --project src/ZB.MOM.WW.LmxOpcUa.Client.CLI -- read -u opc.tcp://localhost:4840/LmxOpcUa -n "ns=3;s=TestMachine_001.MachineID"
# Write a tag
dotnet run --project src/ZB.MOM.WW.LmxOpcUa.Client.CLI -- write -u opc.tcp://localhost:4840/LmxOpcUa -n "ns=3;s=TestChildObject.TestString" -v "Hello"
# Subscribe to changes
dotnet run --project src/ZB.MOM.WW.LmxOpcUa.Client.CLI -- subscribe -u opc.tcp://localhost:4840/LmxOpcUa -n "ns=3;s=TestChildObject.TestInt" -i 500
# Read historical data
dotnet run --project src/ZB.MOM.WW.LmxOpcUa.Client.CLI -- historyread -u opc.tcp://localhost:4840/LmxOpcUa -n "ns=3;s=TestMachine_001.TestHistoryValue" --start "2026-03-25" --end "2026-03-30"
# Subscribe to alarm events
dotnet run --project src/ZB.MOM.WW.LmxOpcUa.Client.CLI -- alarms -u opc.tcp://localhost:4840/LmxOpcUa -n "ns=3;s=TestMachine_001" --refresh
# Query redundancy state
dotnet run --project src/ZB.MOM.WW.LmxOpcUa.Client.CLI -- redundancy -u opc.tcp://localhost:4840/LmxOpcUa
Client UI
dotnet run --project src/ZB.MOM.WW.LmxOpcUa.Client.UI
The desktop application provides browse tree, subscriptions, alarm monitoring, history reads, and write dialogs. See Client UI Documentation for details.
Project Structure
src/
ZB.MOM.WW.LmxOpcUa.Host/ OPC UA server (.NET Framework 4.8, x86)
Configuration/ Config binding and validation
Domain/ Interfaces, DTOs, enums, mappers
Historian/ Wonderware Historian data source
Metrics/ Performance tracking (rolling P95)
MxAccess/ STA thread, COM interop, subscriptions
GalaxyRepository/ SQL queries, change detection
OpcUa/ Server, node manager, address space, alarms, diff
Status/ HTTP dashboard, health checks
ZB.MOM.WW.LmxOpcUa.Client.Shared/ Shared OPC UA client library (.NET 10)
ZB.MOM.WW.LmxOpcUa.Client.CLI/ Command-line client (.NET 10)
ZB.MOM.WW.LmxOpcUa.Client.UI/ Avalonia desktop client (.NET 10)
tests/
ZB.MOM.WW.LmxOpcUa.Tests/ Server unit + integration tests
ZB.MOM.WW.LmxOpcUa.IntegrationTests/ Server integration tests (live DB)
ZB.MOM.WW.LmxOpcUa.Client.Shared.Tests/ Shared library tests
ZB.MOM.WW.LmxOpcUa.Client.CLI.Tests/ CLI command tests
ZB.MOM.WW.LmxOpcUa.Client.UI.Tests/ UI ViewModel + headless tests
gr/ Galaxy repository docs, SQL queries, schema
Documentation
Server
| Component | Description |
|---|---|
| OPC UA Server | Endpoint, sessions, security policy, server lifecycle |
| Address Space | Hierarchy nodes, variable nodes, primitive grouping, NodeId scheme |
| Galaxy Repository | SQL queries, deployed package chain, change detection |
| MXAccess Bridge | STA thread, COM interop, subscriptions, reconnection |
| Data Type Mapping | Galaxy to OPC UA types, arrays, security classification |
| Read/Write Operations | Value reads, writes, access level enforcement, array element writes |
| Subscriptions | Ref-counted MXAccess subscriptions, data change dispatch |
| Alarm Tracking | AlarmConditionState nodes, InAlarm monitoring, event reporting |
| Historical Data Access | Historian data source, HistoryReadRaw, HistoryReadProcessed |
| Incremental Sync | Diff computation, subtree teardown/rebuild, subscription preservation |
| Configuration | appsettings.json binding, feature flags, validation |
| Status Dashboard | HTTP server, health checks, metrics reporting |
| Service Hosting | TopShelf, startup/shutdown sequence, error handling |
| Security | Transport security profiles, certificate trust, production hardening |
| Redundancy | Non-transparent warm/hot redundancy, ServiceLevel, paired deployment |
Client
| Component | Description |
|---|---|
| Client CLI | Connect, browse, read, write, subscribe, historyread, alarms, redundancy commands |
| Client UI | Avalonia desktop client: browse, subscribe, alarms, history, write values |
Reference
- Galaxy Repository Queries — SQL queries for hierarchy, attributes, and change detection
- Data Type Mapping — Galaxy to OPC UA type mapping with security classification
License