Joseph Doherty 2a8e2981fe feat(scripting): ScriptWorker isolation on Windows: restricted worker identity, pipe ACL, firewall + PeCacheDir installer (lmxopcua#780)
v2-ci / unit-tests (push) Has been cancelled
Owner decisions §14 #5/#6 as built (design §12.5):

- Scripting:Worker:Identity (default unset, Windows only, fail-closed validation): each worker
  starts under a restricted token derived from the host's. Every privilege but SeChangeNotify is
  removed; the restricting SIDs are NT SERVICE\OtOpcUaScriptWorker's SID + Everyone + Users +
  RESTRICTED; the token and default DACLs are host + SYSTEM + identity + RESTRICTED. The worker
  is created suspended, put in its Job Object before it runs, inherits only its stdio pipes, gets
  an ACL'd work dir as TEMP, and runs with DOTNET_EnableDiagnostics=0. The identity is granted on
  the host's window station and desktop, because USER32 init made coreclr.dll fail with
  ERROR_DLL_INIT_FAILED on windev. The logon SID is not used because the host's process DACL
  gives it PROCESS_VM_READ.
- The worker pipe on Windows always has an explicit protected DACL: host account + identity
  only. There is no owner ACE, so an elevated host's Administrators gets no access.
- The worker treats access denied on its parent-pid poll as alive; the Job Object covers that case.
- scripts/install/Install-ScriptWorkerIsolation.ps1 + ScriptWorkerIsolation.psm1 are idempotent
  and support -WhatIf, -Uninstall and -PlanOnly. They create the disabled anchor service, the
  PeCacheDir ACL (protected, no Users, key and markers host-only, pe\ Modify for the identity),
  read+execute on script-worker\, a ReadData deny on the install root, the outbound firewall
  block on the worker exe, and optionally the host-service env.
- Tests: the dry-run harness scripts/install/tests/Test-ScriptWorkerIsolation.ps1 (46
  assertions, mutation-checked); ScriptWorkerIdentityTests; WorkerIsolationTests, which cover
  the pipe ACL, token access and a real restricted worker running a script, all green on windev.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-10 08:46:23 -05:00
Joseph Doherty 0e96dd08a2 fix(scripting): deny System.AppContext and other process-wide mutators in the script sandbox (lmxopcua#792)
v2-ci / unit-tests (push) Waiting to run
ForbiddenTypeAnalyzer now denies System.AppContext, System.Console, GCSettings, ProfileOptimization,
EncodingProvider/CodePagesEncodingProvider, TypeDescriptor and CryptoConfig as types, and the ambient
CultureInfo.{DefaultThreadCurrentCulture,DefaultThreadCurrentUICulture,CurrentCulture,CurrentUICulture}
and TimeZoneInfo.ClearCachedData members (member deny-list now covers properties and member-access reads).
Shadow-mode tests diverge via culture-sensitive string.Compare (worker is InvariantGlobalization) instead of
AppContext.BaseDirectory, with a premise test. Mutation-proved: 21 new cases fail with the analyzer reverted.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-10 07:48:39 -05:00
Joseph Doherty 03686eb5d7 feat(scripting): Scripting:Runner=Shadow — in-process results published, each compiled run mirrored to the ScriptWorker pool and compared (lmxopcua#780 P2)
- ShadowScriptRunner (Core.Scripting): IScriptShadow.Mirror copies the inputs and queues the shadow run on the
  pool; compares value (structural), CLR type, status and failure class (compile / budget / threw+message /
  unsupported_type); runner-fault shadow outcomes (Unavailable, worker busy) are not compared. Bounded:
  Scripting:Shadow:MaxInFlight (256) and one per script; drops counted (behind | key_busy).
- Metrics otopcua.script.shadow.{compared,mismatch{script},dropped,inflight}; one rate-limited Warning per
  script and reason with a diff summary (Scripting:Shadow:MismatchLogsPerMinute, re-armed at the seam's deploy).
- The VirtualTag, Calculation and scripted-alarm seams recognise the shadow and keep their in-process path
  byte-for-byte (no coalescer, one-at-a-time pump, in-process engine), mirroring after each compiled run.
- ScriptRunnerSelection builds the shadow over an OutOfProcessScriptRunner whose lines carry
  ScriptRunnerRole=Shadow; Status() is null under Shadow so readiness never sees the shadow pool; the
  script-runner health entry stays Healthy and reports the shadow counters as data.
- docker-dev/docker-compose.script-runner-shadow.yml; docs/VirtualTags.md "Shadow mode".
- Tests: comparison table, per-script metric + once-per-reason log, rate limit, hung/blocking/throwing shadow
  never reaches the caller, MaxInFlight drop accounting, input copy; real-worker divergent + unsupported-type
  scripts counted against exactly those scripts, a worker-only runaway killed/quarantined there with every
  published value intact, alarm transitions identical to in process across a kill -9 of the shadow worker.
  Mutation-proved (16 mutants, 15 red; the one survivor added an assertion).

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-10 07:23:06 -05:00
Joseph Doherty 0796928504 feat(scripting): batch submit, exact per-item deadlines, scripted-alarm seam on the out-of-process runner (lmxopcua#780)
v2-ci / unit-tests (push) Waiting to run
- IScriptRunner.RunBatch: one EvalBatch frame per worker for every evaluation ready to run; per-item, streamed results.
  The default (InProcessScriptRunner) is RunAsync per item. Used by the Calculation pump (dequeue all, split at a
  repeated tag, publish in dequeue order), the VirtualTag seam (ScriptBatchCoalescer, no timer) and the scripted-alarm
  engine (whole dirty set). In process the pump and the engine stay one at a time, unchanged.
- Exact per-item deadlines: the worker hands work to an idle evaluation thread or defers it (EvalResults
  deferred_eval_ids); the host stops that run's clock and restarts T then G when it starts (started_eval_ids). A run
  queued behind a runaway is neither timed out nor struck and is a victim, not the culprit, at the kill.
- Scripted-alarm seam behind Scripting:Runner:Seams; unset Seams now means VirtualTag + Calculation, so alarms run out of
  process only when listed. Load still compiles each predicate (to PE bytes only) so a broken one fails the load; passes
  batch and apply in the serial order under the gate. Script faults freeze the condition BadInternalError; runner faults
  freeze it BadResourceUnavailable and re-evaluate on recovery; a dead worker never clears an alarm. IScriptRunnerProvider
  carries the runner to DriverHostActor.
- Perf harness: batch throughput (RunBatch vs RunAsync x n) and alarm-pass latency (in process / batched / serial);
  design §12.3 records macOS + windev. On windev the serial out-of-process alarm pass misses 250 ms from ~500 alarms;
  batched p99 <= 53 ms at 1,000.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-10 06:37:36 -05:00
Joseph Doherty 000d7f5591 fix(virtualtags): route VirtualTag outputs through the dependency mux so VT->VT reads work (lmxopcua#791)
v2-ci / unit-tests (push) Waiting to run
Proven broken first: VirtualTagToVirtualTagFlowTests (real mux + host + Roslyn
evaluator) failed on master - VT A evaluated, VT B reading A by its key never did.
VT outputs only reached their OPC UA node; the mux carried driver values only.

- VirtualTagHostActor also sends each real result (not re-asserts) and a disabled
  tag's BadOutOfService to the mux as VirtualTagOutput, keyed by the VT's UNS
  NodeId identifier {EquipmentId}/{Name}. Publish path unchanged (single source).
- DependencyMuxActor pins VT outputs (retained with no subscriber, no grace,
  immune to SourceRemoved) and replays them; VirtualTagOutputsRemoved releases
  keys that leave the deployed set.
- DraftValidator: blocking VirtualTagDependencyCycle (A->B->A, self-read, loops
  through Calculation tags, {{equip}} refs resolved); disabled VTs are not nodes.
  EquipReferenceUnresolved names the key form when {{equip}}/<name> is a VT.
- Runtime backstop: the host re-detects VT cycles per apply and does not route
  outputs of tags on one.
- AdminUI ScriptTagCatalog lists VTs by key (the bare leaf name never resolved).
- docs/VirtualTags.md documents the routing, key, retention and cycle rules.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-10 05:17:00 -05:00
Joseph Doherty f201f16fd4 fix(virtualtags): a disabled VirtualTag keeps its node and reads BadOutOfService (lmxopcua#787, owner decision)
v2-ci / unit-tests (push) Has been cancelled
Revises 963b0d66, which dropped a disabled VirtualTag from the runtime plan so a
bound client got BadNodeIdUnknown. Now the plan carries Enabled (part of value
equality): AddressSpaceComposer.Compose and DeploymentArtifact.BuildEquipmentVirtualTagPlans
keep the row with Enabled=false (byte-parity), the applier materialises the node as
normal, and VirtualTagHostActor spawns no VirtualTagActor for it but publishes
BadOutOfService (new OpcUaStatus constant) with a null value stamped at deploy, on
every apply. Enabled flips are node-irrelevant to the change classifier; enabled->disabled
stops the child, disabled->enabled resumes evaluation. Validator exemption and name
uniqueness unchanged. Scripted alarms keep their not-materialised convention.
Tests updated; new wire test DisabledVirtualTagWireTests. docs/VirtualTags.md updated.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-10 04:48:57 -05:00
Joseph Doherty 8582ce91bc perf(scripting): cut out-of-process runner host CPU; compile timeout from compile start; quiet start-failure logs (lmxopcua#789, #790, #788)
v2-ci / unit-tests (push) Has been cancelled
#789 (partial, further tuning deferred): combining inline frame writer, buffered
frame reader, one timer per evaluation for T and T+G, slot release on the reader
before the caller resumes, a non-spinning per-connection result dispatcher, and
blocking pipe I/O on Unix (both ends) so the socket never enters the socket
engine; TerminateJobObject kill on Windows. macOS host CPU at 10k evals/s K=2:
228-240 % -> 79 % (InProcess 69 %, IPC share +10 vs budget 25); windev 153 % ->
123 % (+115, still a miss). Harness reports the "vs InProcess" share, warm-cache
worker RSS, and times kill latency from the soft-timeout answer.

#790: the worker sends LoadStarted; the compile timeout is armed then, so a load
queued behind other compiles is never killed or struck.

#788: one Error with stack per down period, rate-limited Warnings with attempt
count, one Information on recovery.

Design doc §8.2 notes + §12.2 record.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-10 04:25:08 -05:00
Joseph Doherty 963b0d66fc fix(virtualtags): a disabled VirtualTag is no longer deployed or evaluated (lmxopcua#787)
v2-ci / unit-tests (push) Waiting to run
VirtualTag.Enabled was authorable but ignored by both runtime-plan seams.
AddressSpaceComposer.Compose and DeploymentArtifact.BuildEquipmentVirtualTagPlans
now drop disabled rows (byte-parity), so no node is materialised and no
VirtualTagActor is spawned - the same outcome as a disabled scripted alarm.
DraftValidator exempts a disabled VT from VirtualTagNoEffectiveTrigger.
Calculation tags have no Enabled flag, so no equivalent gap. docs/VirtualTags.md updated.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-10 03:15:22 -05:00
Joseph Doherty 1ead8f458a feat(scripting): self-contained script worker publish, docker-dev drill, §8 perf harness (lmxopcua#780 P1)
v2-ci / unit-tests (push) Waiting to run
- A self-contained Host publish (-r win-x64 --self-contained, the Windows installs) now publishes the
  ScriptWorker self-contained for the same RID into script-worker/. The launcher starts its apphost
  directly when runtimeconfig.json lists includedFrameworks. A framework-dependent worker (docker-dev)
  keeps running through the dotnet muxer.
- docker-dev/docker-compose.script-runner.yml: OutOfProcess for the central pair's VT + Calc seams.
  Live drill recorded in design §12.1 (runaway kill + quarantine, kill -9 recovery, open circuit
  with /health/ready still 200, metrics).
- ScriptRunnerPerfTests (Category=Perf, opt-in via OTOPCUA_SCRIPT_PERF=1): InProcess vs OutOfProcess
  at K=1/2/4. The accepted 5k evals/s/node gate passes on macOS and windev. The host-CPU, RSS and
  Windows latency budget misses are tracked as #789.
- Fix: the single-flight slot is released before the awaiting caller resumes. Before, a caller that
  started its next run right after the previous one returned could be refused with "previous
  evaluation still running", which the seams publish as Bad.
- Fix: the worker compiles on dedicated threads, not the thread pool. A burst of cold loads starved
  the heartbeat, and the host killed the shard (found on windev). Load-timeout queueing is #790.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-10 02:53:53 -05:00
Joseph Doherty f50b29abae feat(scripting): PE cache, quarantine-race fix, recovery, readiness for the out-of-process runner (lmxopcua#780 P1)
v2-ci / unit-tests (push) Failing after 1h12m10s
Second P1 slice of docs/plans/2026-11-09-out-of-process-script-runner-design.md; still opt-in behind
Scripting:Runner=OutOfProcess (InProcess unchanged).

- Compiled-PE cache (design §7, §14 #8): Scripting:Worker:PeCacheDir holds <dir>/pe/<id>.pe entries authenticated
  with HMAC-SHA256 under a per-node random key (<dir>/pe-cache.key, created by the host, 0600/0700 on Unix), handed to
  the worker in Hello. Entry id = SHA-256(compile fingerprint + kind + source); the fingerprint covers the Roslyn
  version, the Core.Scripting build (analyzer, wrapper, stack guard), the sandbox reference set and the runtime. Edited,
  truncated, other-key or renamed entries are rejected, deleted and recompiled; the worker never loads unverified bytes.
  Pruned by recency at startup (30 d / 50 000). ScriptEvaluator splits into CompileToImage + FromImage. Measured on
  40 scripts, restart to every first result: macOS 820 ms no cache / 840 ms empty / 85 ms warm;
  windev (Windows) 9.5 s / 9.4 s / 1.0 s.
- Quarantine race: WorkerConnection runs exit attribution synchronously BEFORE completing the evaluations/loads it held
  (and before Exited), and the shard passes it straight to the runner — a kill strike is in place before the killed
  key's slot is released.
- Supervision: a dead worker restarts by itself after its backoff; Unavailable outcomes carry ScriptRunOutcome.Recovery
  (-> VirtualTagEvalResult.RetryWhen) and the VT actor / Calculation driver re-evaluate once against current inputs when
  it completes. Isolation worker stops after Scripting:Worker:IsolationIdleTimeout (10 min). Keys compiling when a
  worker dies are suspects too (isolation finds a poison compile and quarantines it). Startup orphan sweep by launch
  marker: kills only a process whose marker's host is gone and whose pid + start time + image match.
- Crash-loop circuit (Scripting:Worker:CircuitOpenAfter, 2 min): runner Unavailable, one Error, evaluations answered
  at once while shards keep retrying at the cap.
- Observability (§10): otopcua.script.runner.state, worker.up/inflight/queue_depth/heap_bytes (shard),
  ipc.roundtrip + eval.duration (kind), compile{cache}, isolation.suspects, exits reason=idle. `script-runner` health
  check on the ready tier, at worst Degraded (§14 #12: degraded but still ready).

Left on #780: self-contained worker publish, installer (account, pipe ACL, firewall), docker-dev live drill,
scripted-alarm seam, the §4.5 per-seam batch submit, the §8 perf harness.

Tests: SupervisionTests, PeCacheStoreTests/PeCacheWorkerTests (real workers), ScriptRunnerHealthCheckTests, VT + Calc
recovery seam tests; 14 mutations each turned their test red.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-10 00:20:24 -05:00
Joseph Doherty 69a6e0b4c8 feat(scripting): out-of-process pre-emptible script runner behind Scripting:Runner (lmxopcua#780 P1)
v2-ci / unit-tests (push) Waiting to run
Opt-in (Scripting:Runner=OutOfProcess; InProcess stays the default and its code path is unchanged). Implements
the P1 slice of docs/plans/2026-11-09-out-of-process-script-runner-design.md with the owner's §14 decisions:

- Options: Scripting:Runner (InProcess | Shadow | OutOfProcess), Scripting:Runner:Seams, Scripting:Worker:*
  (Shards 2, HardGrace max(1 s,T), HeapLimitBytes 512 MiB, QuarantineAfterKills 2, UnavailableGrace 5 s,
  IsolationProbationRuns 20, PeCacheDir validated absolute + outside the content root (fail closed),
  ExecutablePath). Shadow is not implemented yet: runs InProcess with a startup Warning.
- Core.Scripting: IScriptRunner seam + InProcessScriptRunner (today's guard, the parity baseline).
- Core.Scripting.Protocol: protobuf envelopes, 4-byte LE framing (zero/oversize/truncated/garbage refused),
  Variant carrying the exact CLR type; unsupported types are explicit failures.
- ScriptWorker app: compiles in the worker, P-thread scheduler, host-driven soft cancel, fail-fast
  watchdog, heartbeats, ctx.Logger forwarding, exits on pipe EOF / parent gone, forbidden-assembly
  self-check; Akka and Grpc.Core.Api excluded from its folder. Shipped in script-worker/ (Build + Publish).
- Core.Scripting.OutOfProcess: K shards + isolation worker, soft T / hard T+G kill, attribution
  (deadline kill = one key; crash = suspects -> isolation; isolation crash = strike), kill-strike
  quarantine, backoff 250 ms -> 30 s, fail closed, cleared allow-listed env, nonce + pid handshake on a
  current-user pipe, Windows Job Object.
- VirtualTag + Calculation seams use the runner when selected; a runner-side failure (worker restarted /
  runner unavailable) publishes BadResourceUnavailable (0x80040000) — ScadaBridge#112. Script faults keep
  BadInternalError. The scripted-alarm seam stays in process (alarms last).

Tests: new ZB.MOM.WW.OtOpcUa.ScriptWorker.Tests (Category=ScriptWorker, real processes; green on macOS and
on windev/Windows), seam tests in Host/Runtime/Calculation suites; mutation-checked.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 23:33:08 -05:00
Joseph Doherty f5c30ed0ef feat(sql): authored write block — Update/Insert/Upsert/Procedure + timestamp stamp; ODBC scope + login docs (lmxopcua#781)
v2-ci / unit-tests (push) Has been cancelled
Item 2: a tag's optional `write` block picks the statement the driver builds from its own
catalog-validated identifiers (no authored SQL; values always bound):
- Update (default, unchanged back-compat UPDATE ... WHERE key; 0 rows = BadNoData)
- Insert (key+value[+stamp]; append for a WideRow topByTimestamp tag)
- Upsert: SQL Server MERGE WITH (HOLDLOCK), PostgreSQL INSERT ... ON CONFLICT, MySQL
  ON DUPLICATE KEY UPDATE (1-or-2 rows), Oracle MERGE from DUAL
- Procedure: named stored procedure resolved against the routine catalog by the catalog gate
  (INFORMATION_SCHEMA.ROUTINES / ALL_PROCEDURES), value/key/timestamp params by name (MySQL positional)
- stampTimestamp sets the tag's timestamp column to the write time (UTC)
Odbc serves Update/Insert only (shared SqlWriteSupport table). Constraint failures map to
BadEntryExists (unique) / BadOutOfRange (other integrity, data exception); everything else,
permission denied included, stays BadCommunicationError. WriteIdempotent stays false.
The parser refuses malformed blocks (strict keys/enums/param charset); DraftValidator emits
blocking SqlWriteBlockInvalid / SqlWriteModeUnsupported from the driver's own parse; the AdminUI
editor surfaces the same message.

Items 1 + 4 (docs/drivers/Sql.md): ODBC stays the ANSI SQL:2008 profile (native providers for
SQL Server/MySQL, DB2 unsupported) with an ops note on driver manager + vendor driver on every
Odbc and AdminUI host; read-only drivers require a SELECT-only login, writable drivers a login
limited to their write targets.

Tests: SqlWriteModeTests (parse, every dialect's SQL, gate, status map, SQLite end-to-end),
DraftValidatorSqlWriteBlockTests, AdminUI round-trip; live SqlWriteModesLiveTests on SQL Server,
PostgreSQL, MySQL, Oracle (seeds gain write_targets + set_target) and an Odbc write leg.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 22:59:09 -05:00
Joseph Doherty 850c5405d0 fix(scripting): name the script on the mirrored quarantine line; keep BadInternalError (lmxopcua#784)
v2-ci / unit-tests (push) Has been cancelled
(a) ScriptRunGuard logs its quarantine Error through the seam's script root
logger, which carries no ScriptName, so ScriptLogCompanionSink mirrored it to
the main log as "[Script] unknown emitted Error ..." and rate-limited every
quarantine on the node under one shared "unknown" key. The guard now binds the
script instance key as ScriptName (ForContext) on the quarantine Error and the
subscriber-threw Warning, so the mirror names the script and limits each one
separately. Test drives two real quarantines through the companion sink with a
1-per-window limiter: both mirrored, each named, none "unknown". Mutation-
checked: dropping the ForContext fails it.

(b) Evaluated a quarantine-specific OPC UA status (BadOutOfService) and kept
BadInternalError: it is the documented code for any script-attributable fault
on virtual tags, Calculation tags and scripted-alarm quality (and the
out-of-process runner design keeps it), BadOutOfService reads as a deliberately
disabled point, a new code is a ScadaBridge-visible contract change, and the
once-per-Good->Bad dedup means a timeout-driven quarantine would rarely show a
different code anyway. Documented in docs/VirtualTags.md ("Quarantine: what a
client sees"), with pointers from Calculation.md, ScriptedAlarms.md and the
OpcUaStatus.BadInternalError doc comment, plus where a quarantine IS visible.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 21:30:17 -05:00
Joseph Doherty d9b95dcf56 fix(virtualtags): consume VirtualTag.TimerIntervalMs; add VirtualTagNoEffectiveTrigger gate (lmxopcua#783)
v2-ci / unit-tests (push) Waiting to run
Choice: implement the timer (option a). The field was designed and promised as a
working trigger: the entity doc says ChangeTriggered and TimerIntervalMs together
realize the trigger model, the DB check constraint requires ChangeTriggered OR a
timer >= 50, the AdminUI virtual-tag modal exposes "TimerIntervalMs (optional)" and
UnsTreeService rejects a tag with neither, and the 2026-06-08 design specified
"ChangeTriggered OR TimerIntervalMs>=50". Only the runtime never honoured it (the
standalone TimerTriggerScheduler was deleted in #603), so a timer-only tag sat at
BadWaitingForInitialData forever.

- EquipmentVirtualTagPlan carries ChangeTriggered/TimerIntervalMs (in equality, so
  an edit respawns the child); both the composer and the artifact decode fill them.
- VirtualTagActor schedules a repeating tick (PreStart, cancelled in PostStop,
  clamped to the 50 ms floor). ChangeTriggered=false makes the timer the only
  trigger. A tick during an in-flight async run (#779) is dropped, not stashed, so
  slow scripts never build a backlog of runs.
- DraftValidator VirtualTagNoEffectiveTrigger (hard error, same severity as
  CalculationNoEffectiveTrigger): no timer and no change trigger with a literal
  ctx.GetTag read.

Tests: VirtualTagActorTimerTests, DraftValidatorVirtualTagTriggerTests, artifact
decode test. Mutation-checked: no scheduling, stashing ticks, no cancel in
PostStop, and removing the validator call each fail a test.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 21:27:59 -05:00
Joseph Doherty 241318e7e5 feat(deploy): reject Sql Query tags naming undeclared queries; warn on Writable/writable disagreement (lmxopcua#781)
v2-ci / unit-tests (push) Has been cancelled
Item 5: DraftValidator now emits SqlQueryNotDeclared (always blocking) for a Query tag whose
query is absent from the merged driver config's queries map, via the driver's own tag parse.
Item 3: StartDeployment appends a non-blocking warning to the accepted message when the Tag
entity's AccessLevel and the Sql blob's writable flag disagree.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 18:08:54 -05:00
Joseph Doherty 9e8b5b0ea7 fix(scripting): stop unbounded script recursion from killing the server (lmxopcua#779)
Reproduced first, out of process (ScriptRecursionContainmentTests re-launches
the xunit v3 test assembly to run one recursive script through
ScriptEvaluator + ScriptRunGuard, so the runner never executes one): before
this change every shape — local function, mutual local functions,
self-referencing Func<>, anonymous self-application, recursion through LINQ,
an expression-bodied void lambda, an anonymous method — ended the child with
exit 134 (SIGABRT, "Stack overflow."). A StackOverflowException cannot be
caught, so in production one script takes the whole node down.

Fix: ScriptEvaluator.Compile now rewrites the validated wrapper
(ScriptStackGuardInjector, after ForbiddenTypeAnalyzer) so the script body and
every lambda, anonymous method and local function starts with
ScriptStackGuard.Check(), which throws ScriptStackExhaustedException when
RuntimeHelpers.TryEnsureSufficientExecutionStack reports the stack nearly
spent. The script then fails like any throwing script (Bad, script log) and
the process lives.

Why a runtime check, not an analyzer rule: recursion is not decidable from
syntax (anonymous self-application never names itself), and bounded recursion
must keep working. Expression-bodied lambdas/local functions become blocks
(`return e;` or `e;`, chosen from the bound symbol, so the same overload
binds); expression-tree and async lambdas are left alone. Limits (documented
on ScriptStackGuard and in docs/VirtualTags.md): depth depends on the thread's
stack size; a recursion that never re-enters script code is not seen; a script
may catch the exception, which only unwinds it.

Tests: ScriptRecursionContainmentTests (7 shapes, child process each; all 7
fail with exit 134 when the rewrite is disabled), ScriptStackGuardInjectionTests
(bounded recursion and every rewritten lambda/local-function shape keep their
value; the expression-tree case fails if those lambdas are rewritten).

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 17:44:35 -05:00
Joseph Doherty a84d38707b fix(virtual-tags): evaluate scripts off the Akka dispatcher thread (lmxopcua#779)
VirtualTagActor called the blocking IVirtualTagEvaluator.Evaluate, and
RoslynVirtualTagEvaluator blocked on the run guard with
.GetAwaiter().GetResult(), so every script run parked a dispatcher thread for
up to its 2 s budget (a first-use Roslyn compile did too). This is the #750 P0
refactor for virtual tags.

- IVirtualTagEvaluator.EvaluateAsync (default: a completed task over the
  snapshot overload, so the null evaluator and fakes are unchanged).
- RoslynVirtualTagEvaluator implements it without blocking: passthrough and
  compile failures complete synchronously, a first-use compile goes to the
  pool, the run is awaited. The blocking overload now delegates to it.
- VirtualTagActor: a completed task is applied in the same turn, as before;
  an incomplete one switches to an "evaluating" behaviour that stashes every
  dependency/reassert message until a private completion message arrives,
  then applies the result and unstashes. Each trigger is still evaluated
  against its own inputs, results are applied/published in trigger order and
  the dedup/Bad-transition state sees the same sequence. The dependency map is
  not touched while a run reads it.

Calculation and scripted-alarm serialisation is NOT relaxed: neither blocks a
thread, and running independent scripts in parallel is not semantics-neutral
(pool consumption bound, cross-tag publish order, timer/pump exclusion for
Calc; state-machine/persist boundary, transition timestamps and the
store-failure path for alarms). Recorded in docs/VirtualTags.md and the #750
design's P0 entry.

Tests: VirtualTagActorAsyncEvaluationTests — on a one-thread dispatcher a slow
script no longer starves a sibling actor and the slow actor answers Identify
(fails when the actor calls the blocking Evaluate); triggers during a run are
evaluated afterwards in order against their own inputs; a reassert during a
run is applied after it; a faulted evaluation takes the evaluator-threw path
(the ordering/reassert tests fail with the stash removed).
RoslynVirtualTagEvaluatorAsyncTests — a slow script and a cold compile return
an incomplete task (fail without the override); cheap outcomes and timeouts
match the blocking overload.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 17:44:35 -05:00
Joseph Doherty d683b83156 fix(scripting): give scripted-alarm predicates the configured run budget, not 250 ms (lmxopcua#779)
DriverHostActor built ScriptedAlarmEngine without a scriptTimeout, so every
production alarm predicate fell back to TimedScriptEvaluator.DefaultTimeout
(250 ms) while virtual tags and Calculation tags ran on 2 s. History shows no
decision behind it: 250 ms is the generic Phase-7 A.4 default, the VT
evaluator moved to 2 s in F8b (219d10a2) and the alarm engine was simply never
given a value.

- New node-wide Scripting:RunTimeout (default 2 s, clamped to (0, 60 s],
  non-positive -> default, each clamp a startup Warning) on ScriptingOptions.
- The VT evaluator and the alarm engine default to it; DriverHostActor now
  builds the engine through CreateScriptedAlarmEngine, which passes it
  explicitly. Calculation keeps its per-driver runTimeoutMs.
- Docs: ScriptEditor (config table), ScriptedAlarms, VirtualTags.

Tests: ScriptedAlarmEngineBudgetTests (a 600 ms predicate now completes and
activates; default and configured budgets), ScriptedAlarmEngineBudgetWiringTests
(the host-built engine), ScriptingOptionsBindingTests (bind + clamps). The
engine and wiring tests fail with the old 250 ms default restored.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 17:44:35 -05:00
Joseph Doherty 97dc715dac fix(runtime): derive every write bound and Ask from one write timeout (lmxopcua#777)
v2-ci / unit-tests (push) Has been cancelled
Three write bounds were configured independently: the inbound-write
gateway's 10 s Ask, DriverHostActor's fixed 8 s Ask of the child, and the
child's own write timeout (5 s + up to 2 s grace) with a fixed 8 s queue
budget. An outer Ask that fires first reports the write failed and the node
reverts while the child is still driving the device, so any write timeout
above ~6 s (or a write dequeued late in its 8 s budget) let the device take
a value the client was told failed.

DriverWriteBounds (Runtime) derives them all from DriverWrites:Timeout:
  token cancel   = Timeout
  abandon        = Timeout + min(Timeout/2, 2 s)            (RunBound)
  queue budget   = RunBound
  child replies  <= queue budget + RunBound                  (ReplyBound)
  host Ask       = ReplyBound + 1 s
  gateway Ask    = host Ask + 1 s
Default Timeout is 10 s (the Tier C Write timeout, so no tier default is
capped below its own policy); host Ask 25 s, gateway Ask 26 s. Tier A/B
writes are still cancelled first by their 2 s / 4 s tier timeouts.

- DriverHostActor takes writeBounds + writeClock, spawns children with them,
  and runs its Ask deadline as a token on the write clock (Infinite Akka
  timeout), so host and child bounds share one clock.
- WriteAttribute gains IssuedAt (write-clock timestamp, stamped by the
  host): the queue budget counts mailbox time too, and a write past it is
  failed BadTimeout and never started - including on arrival. Stale queued
  writes are expired across the whole queue, not only up to a free slot.
- ActorNodeWriteGateway's default Ask = Default.GatewayAsk; the hosted
  service passes the configured one.
- Startup validation (Host DriverWriteBoundsBinding, same warn-and-clamp
  style as ScriptingOptionsBinding): unparsable / non-positive -> default,
  above 5 min -> clamped, and each tier whose default Write timeout exceeds
  the write timeout is named in a Warning (its policy would never take
  effect). The derived bounds are logged at Information. Per-instance
  ResilienceConfig Write overrides arrive with a deployment, so
  DriverCapabilityInvokerFactory warns at spawn (writeTimeoutCeiling).
- appsettings.json documents DriverWrites:Timeout.

Tests (manual clock):
- DriverHostActorWriteAskTests: a held write under a 9 s timeout survives
  an 8.5 s step and succeeds; a token-ignoring write is answered by the
  child's BadTimeout at 9 s + grace, not by the Ask; the Infinite-timeout
  Ask ends exactly at its clock deadline.
- DriverInstanceActorConcurrentWriteTests: a write issued longer ago than
  the queue budget is failed and never reaches the driver; positive control
  at exactly the budget is written.
- DriverWriteBoundsTests: every outer bound covers the inner ones for 0.5 s
  to 300 s timeouts.
- DriverWriteBoundsBindingTests: default fits every tier; 3 s timeout is
  caught at startup with Tier B and C named (not A); bad values fall back
  with a warning; over-max clamps.
- DriverCapabilityInvokerFactoryTests: spawn warns when a Write override
  exceeds the ceiling; no warning within it or without a ceiling.
Mutation checks: a fixed 8 s host Ask on the same clock fails both 9 s host
tests; stamping arrival time instead of IssuedAt fails the issued-at test;
dropping the tier check / factory check fails their tests.

Runtime.Tests 961 passed / 3 skipped at AKKA_TEST_TIMEFACTOR 3 and 1;
Host.Tests 232/232 at 3 and 1; Core.Tests 361 passed / 1 skipped.
Solution Release build: 0 warnings.

ContinuousHistorizationRecorderTypedValueTests (historian) deliberately
left for the historian lane.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 15:46:30 -05:00
Joseph Doherty 29665c1872 feat(opcua): HistoryReadEvents projects EventType, ConditionName, SourceNode; honours the where-clause (lmxopcua#746)
HistoryReadEvents projected only EventId / SourceName / Time / ReceiveTime /
Message / Severity: a select clause asking for EventType, ConditionName or
SourceNode (what most generic alarm viewers ask for) got nulls, and the
event filter's where-clause (an OfType) was ignored.

- HistoricalEvent gains optional EventTypeName, ConditionName and AlarmId.
  SqlServer, QuestDB and Gateway event reads fill them from what their
  alarm writers already store (AlarmTypeName / AlarmName / AlarmId; the
  gateway event Type and its AlarmName / AlarmId properties).
- The node manager maps the type name to its Part 9 event type (unknown or
  non-event => AlarmConditionType), projects ConditionName, and resolves
  SourceNode to the materialised condition the alarm id names (the live
  events' SourceNode), else null.
- The where-clause is evaluated per event with the SDK content filter
  through an IFilterTarget (OfType via the type tree; other operators
  against the projected fields), after the page's cursor is taken, so
  paging is unchanged.

Tested in the node manager, over a real client session (the Client.CLI has
no `historyread --events` mode yet; filed as a follow-up), and by alarm
writer -> event read round trips on SqlServer and QuestDB.

Rebased from the unpushed remed/lane-H2 branch (originally authored 2026-10-22
in session_01Ub9hGmYLQvn9XETzw7CMsT) onto current master.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 15:40:47 -05:00
Joseph Doherty 919009c5ef fix(ablegacy): stamp health from the injectable Clock; drop the redundant per-project TreatWarningsAsErrors (lmxopcua#768)
AbLegacyDriver stamped LastSuccessfulRead (init, read, write), the read's sample
timestamps and host-state change times from raw DateTime.UtcNow; only the backoff
path read the injectable Clock. All of them now read Clock(), so
NativePcccBridgeStatusHealthTests drives a manual clock (init at T0, read at T1)
and asserts LastSuccessfulRead == T1 exactly instead of spin-waiting for the wall
clock to pass the init stamp (#767). Without the driver change the 6 tests fail
(init stamp is wall-clock, not T0).

Directory.Build.props sets TreatWarningsAsErrors for every project since #766, so
the 75 per-csproj copies (64 src + 11 tests) are removed and the props comment
says it is now the only place. tools/mem-probe keeps its explicit opt-out.
Release build: 0 warnings, 0 errors; a planted CS0168 still fails the build in a
src project and in a test project that used to carry its own copy.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 13:40:07 -05:00
Joseph Doherty 8e8d4cdf13 fix(alarms): surface a refused native alarm ack synchronously, revert one that fails later (lmxopcua#760)
The native-ack path is fire-and-forget after the Part 9 Acknowledge returns, so
a Galaxy ack refused for lack of a credential (#749), or rejected by MXAccess,
left the client with Good and the condition showing Acknowledged while Galaxy
was never acked. Both options from the issue, layered:

1. Synchronous refusal for what the driver can decide without I/O. New optional
   IAlarmAcknowledgePreflight (Core.Abstractions); GalaxyDriver refuses an
   anonymous session when the driver has no AlarmAck fallback account.
   DriverHostActor publishes a condition NodeId -> owning-driver snapshot into
   NativeAlarmAckPreflightView (lock-free, volatile); the node manager's new
   NativeAlarmAckPreflight seam, consulted after the authz and Primary gates,
   returns BadUserAccessDenied with the reason - nothing routed, applied or
   reported. A keyed session is not pre-checked (its identity lives in the
   Secrets store, which must not be read under the SDK lock).

2. Revert for everything else. RouteAlarmAck carries the condition NodeId;
   DriverInstanceActor replies AlarmAckFailed on a refusal, a backend failure,
   a driver without an alarm source, or an ack dropped while connecting /
   reconnecting. DriverHostActor re-projects the condition unacknowledged via
   NativeAlarmProjector.TryRevertAcknowledge, but only while the local ack is
   still pending - any driver transition projected since then wins. A disabled
   or unspawned driver is not reverted (unchanged).

GatewayGalaxyAlarmAcknowledger now throws DriverOperationRefusedException on a
non-zero native hresult (wrong password, no ack permission) instead of only
warning, so that case reverts too; as a refusal it neither retries nor trips
the breaker.

Tests (each fails with its fix mutated out): projector revert/supersede,
DriverHostActor refused + failed ack -> unacked AlarmStateUpdate (successful
ack control), preflight view snapshot, node-manager preflight unit test,
over-the-wire ConditionMethodEventTests (BadUserAccessDenied, no route, no
event; positive control), Galaxy preflight + hresult refusal.
Docs: Galaxy.md, AlarmTracking.md, ScriptedAlarms.md, .claude/rules/alarms.md.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 13:12:17 -05:00
Joseph Doherty acfb4fbaca fix(redundancy): a failed OPC UA endpoint drops ServiceLevel to 0 and steps the Primary down (lmxopcua#762)
v2-ci / unit-tests (push) Has been cancelled
IOpcUaEndpointState (review-remediation lane C3) recorded whether the SDK started, but only the
health check read it: a fused node whose endpoint failed (port 4840 taken, ...) still advertised
250/240 and stayed driver Primary, so the Primary-gated data plane ran on a node no client could
reach while the reachable peer refused writes as Secondary.

- Move IOpcUaEndpointState/OpcUaEndpointState/OpcUaEndpointStatus from Host to Commons.OpcUa so
  the Runtime can consume it.
- ServiceLevelCalculator: new NodeHealthInputs.EndpointListening (default true). false -> 0,
  ahead of every other input including the +10 Primary bonus.
- OpcUaPublishActor: takes the endpoint state, feeds EndpointListening (Failed only; NotStarted /
  Stopped are boot/shutdown windows) on the DB-backed and DB-less paths, and the legacy role-only
  seam returns 0 for a failed endpoint too.
- New OpcUaEndpointStepDownActor (one per driver node): a Primary (ClusterActiveNode.SelfIsActive,
  the election's own primitive) with a Failed endpoint gracefully Leaves its mesh - the manual
  failover mechanism - so the peer becomes the oldest Up driver member, hosts the singletons and is
  Primary. The election itself is not bent. Guarded on a peer having recently reported its own
  endpoint listening (EndpointReport on the new opcua-endpoint-state DPS topic), so a pair with
  both endpoints failed does not bounce the role and restart nodes forever, and a lone node never
  shuts itself down.
- Runtime now references ZB.MOM.WW.Health.Akka (ClusterActiveNode).
- Docs: Redundancy.md tier table + new "Endpoint start failure: Primary step-down" section;
  cluster-topology rule; HealthEndpoints / OpcUaEndpointHealthCheck comments (F-C1 landed).

Tests: ServiceLevelCalculatorTests (+5), OpcUaPublishActorEndpointStateTests (7: DB-less,
DB-backed, legacy seam, NotStarted/Stopped do not demote, a later failure demotes on the next
tick), OpcUaEndpointStepDownActorTests (3, real two-node mesh: holds while the peer is not
listening then leaves and the peer becomes Primary; failed Secondary and healthy Primary never
leave). Each was mutation-checked: removing the calculator/legacy guard, the Leave, the
peer-listening guard or the Primary guard fails the corresponding tests.
2026-11-09 12:16:37 -05:00
Joseph Doherty dc0a24f224 feat(galaxy): operator-authenticated alarm ack — send Galaxy credential to mxaccessgw (#749)
v2-ci / unit-tests (push) Failing after 1h8m43s
mxaccessgw 488649c+ acknowledges by AuthenticateUser as the operator and
writing <alarm>.AckMsg, so AcknowledgeAlarmRequest now needs a real Galaxy
operator_user + operator_domain + operator_password. The OPC UA data plane is
API-key/anonymous and carries no Galaxy password, so the driver resolves the
account per ack:

1. the session's API key's Galaxy ack identity, set on AdminUI /apikeys and
   held ONLY in the encrypted Secrets store
   (otopcua/apikeys/<keyId>/galaxy-ack-{user,password}); a key with a user but
   no password secret is refused, never silently downgraded;
2. else the driver instance's AlarmAck fallback account (DriverConfig
   FallbackUser/FallbackDomain/FallbackPasswordSecretRef; secret:/${secret:}/
   env:/file:/dev: only — a literal is refused);
3. else DriverOperationRefusedException: nothing is sent, never an empty
   operator_user. Refusals are excluded from the resilience retry/breaker.

- Pins ZB.MOM.WW.MxGateway.Client/Contracts 0.2.1 -> 0.3.0 (vendored into
  nuget-packages/ from the Gitea feed, per the local-mxgw source mapping).
- The session ApiKeyId (not a secret) rides NativeAlarmAck ->
  RouteNativeAlarmAck -> RouteAlarmAck -> AlarmAcknowledgeRequest; the password
  is resolved in the driver and never travels through actor messages.
- The OPC UA principal + key id are appended to the AckMsg comment
  ("[OPC UA: <principal>, key <id>]") and logged, so a shared fallback
  account does not lose who acknowledged.
- Password never logged: GalaxyAckCredential.ToString omits it, the
  acknowledger scrubs it from every gateway message it echoes and withholds
  any exception that echoes it; audit rows carry only the key id.
- AdminUI: /apikeys "Ack identity" editor (set/remove; delete-key clears it),
  Galaxy driver form gains the fallback section.
- Synchronous OPC UA status for a refusal is follow-up #760 (the native ack
  path is fire-and-forget after the Part 9 method returns).

Tests: request mapping (password populated), password absent from logs and
exception text (mutation-checked), key-mapped / fallback / refused paths at
resolver and driver level, breaker non-trip, key-id propagation through node
manager and DriverHostActor, AdminUI service + form round-trip.

Closes #749
2026-11-06 16:23:00 -05:00
Joseph Doherty cf62007678 fix(arrays): Modbus row honours the FC16/FC03 protocol ceilings, the RMW read cap and the address-space end
Review r0 of Integration-W3:
- I1: the effective FC16 cap is min(configured maxRegistersPerWrite, 123). The
  driver trusts a larger configured cap and sends an over-ceiling FC16 (past 127
  registers its byte-count byte wraps), which every conformant device refuses, so
  such an array is never advertised writable.
- I2: a BitInRegister[] write reads its span first in one unchunked FC03, so it is
  also bounded by min(configured maxRegistersPerRead, 125) (absent/0 = 125).
- m2: every span (registers and coils) must end at or before address 65535.
- m1: the String-node wording says it converts only when the text parses, which
  the server cannot promise (DateTime never converts).
- m4: the parity device now enforces FC01/02 2000, FC03/04 125 (or a smaller
  device read limit), FC15 1968, FC16 123, FC23 121/125, the FC15/FC16 byte-count
  field (exception 03) and the address-space end (exception 02).

Tests: parity rows for each ceiling/cap/span boundary against the real write
path, and Core.Abstractions row tests. The configured-cap test that asserted a
cap of 200 lifts the ceiling now asserts the opposite.

Refs #741

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 17:32:57 -04:00
Joseph Doherty 8699614d2f Merge commit '82380d2b' into remed/integration-w3 2026-10-22 17:21:38 -04:00
Joseph Doherty 5533de6281 feat(arrays): Modbus String[]/BitInRegister[] array writes reachable; table follows the resolver
The Modbus lane (#741 U3) gave the driver String[] and BitInRegister[] holding-register array encoders, and
moved address resolution to ModbusTagAddressResolution (keys first, a bit region coerced to Bool, strict key
reads), but DriverArrayWriteSupport still listed both array shapes read-only (follow-up F1), so a client
write was BadNotWritable before it reached the driver.

Modbus row now mirrors the driver end to end:
- Keys shape only (region + address both present). A string-only addressString tag is resolved by the
  driver with its own family through a parser Core.Abstractions cannot reference, so it stays read-only
  (pinned: the conservative direction).
- Strict reads as the resolver: address an integer 0-65535; a present region / dataType / byteOrder /
  stringByteOrder string must name a member.
- Coils: any dataType (coerced to Bool), <= 1968 coils (FC15).
- HoldingRegisters (FC16, never Bool): numeric, String ((stringLength+1)/2 registers, stringLength >= 1),
  BitInRegister (1 register, bitIndex 0-15, span ending <= 65535), all within maxRegistersPerWrite.
  FC23 is opt-in and never changes the answer.
- Elements convert (ScadaBridge int[] -> Int16 stays writable); only a String / DateTime node over a
  numeric or bit element is left out, since such an element never converts.

Tests: the parity test's PendingF1 exemption and its guard are gone; the parity matrix is now region x
element type x node type against the real WriteAsync with a spec-conformant device (FC15 > 1968 refused),
plus shape edges at every cap boundary (numeric, String, BitInRegister, coil), strict key reads, FC23
on/off, string-only, the ScadaBridge int[] shape and U3 wire bytes. Core.Abstractions row tests and a
composer test (String[] and BitInRegister[] writable; over-cap, no-stringLength and string-only read-only).
Docs: table XML doc, Uns.md, modbus-addressing.md, drivers/Modbus.md, data-plane rules.

Refs #741

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 17:10:00 -04:00
Joseph Doherty dad28d37a2 fix(alarms): never drop a comment-trail entry on pair divergence (E5 review r1)
I-1: a node whose in-memory trail is one short of the stored trail (it missed
a command the peer applied, whose entry then replicated in) silently dropped
its own next entry — in failover, the survivor's newest ack — because the
positional "past MAX(seq)" rule treated it as already stored.

SaveAsync now reconciles the last 16 in-memory entries against the stored
rows from that position on, by content (Kind/User/Text, timestamps within a
5-minute skew window; matched rows are consumed so repeats count). The peer's
copy of the same command is recognised and not re-appended; an unmatched
entry is inserted at its own ordinal when free, otherwise appended at
MAX(seq)+1 with a Warning — kept, never silent. Bounded read, constant write.

m1: MigrateInlineComments copies only — it no longer UPDATEs the condition
row (a fresh-HLC re-stamp could beat a newer peer ack under LWW); the next
save clears comments_json. m2: it returns unparseable alarm ids and OnReady
logs a Warning per id (+ an Information tally). m3/m4: documented in the
store remarks (Remove vs lagging peer; in-memory index == durable ordinal).

Tests: store-level failover sequence (missed command -> survivor's ack and
next entry persisted once, re-save writes 0 rows, one Warning) with the
dual-write positive control (peer copy present -> 0 rows, no Warning) and a
repeated-identical-comment case; a loopback pair failover test (link down,
survivor acks, rejoin -> both entries on both peers, held); migration
no-row-rewrite, partial fill and unparseable reporting; OnReady Warning.
Both failover tests fail against the round-0 store.

Refs #748
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 16:58:46 -04:00
Joseph Doherty 13f1357ad2 Merge master d520f77b into remed/lane-E5
Refs #748
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 16:46:30 -04:00
Joseph Doherty 846c8d6335 fix(alarms): move scripted-alarm comment trail to its own append-only table (R05:4)
Every Part 9 transition used to re-serialize the alarm's whole comment trail
into alarm_condition_state.comments_json and replicate it to the pair peer:
O(n) per transition, O(n^2) over an alarm's life (measured: one ack at 10k
comments shipped 1,080,553 oplog bytes; now ~1.6 KB, the same as at 10).

- New replicated table alarm_condition_comment, PK (scripted_alarm_id, seq),
  seq = the entry's ordinal in the trail. Ordinal (not content) keying makes
  the two pair nodes' copies of one logical entry (each stamped by its own
  clock, since both nodes apply every command) collapse to one row under LWW.
- LocalDbAlarmConditionStateStore.SaveAsync appends only entries past the
  stored MAX(seq) (INSERT OR IGNORE, append-only) and upserts a fixed-size
  condition row with comments_json = "[]", in one transaction. Remove drops
  the trail with the row. Load merges the table with any inline trail.
- comments_json column kept (always "[]") so the condition table's shape and
  replication digest are unchanged and old-shape rows still load exactly.
- AlarmConditionStateSchema.MigrateInlineComments: idempotent per-row move of
  inline trails, run by LocalDbSetup.OnReady after RegisterReplicated so the
  moved entries replicate. Comment table joins ReplicatedTables (now five).

Tests: constant transition payload at 10 vs 10k comments (+ instrument
positive control), old-shape back-compat load, migration idempotency /
partial re-run / lazy move, OnReady boot migration captured in the oplog,
and two loopback pair tests (A->B and B->A trail convergence; the shared
entry converges to one copy, with a distinct-alarm positive control).

Refs #748
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 16:36:33 -04:00
Joseph Doherty 44ea6595e5 feat(arrays): advertise AbCip/AbLegacy/TwinCAT array writes in DriverArrayWriteSupport
The Wave-2 lanes gave AbCip, AbLegacy and TwinCAT real whole-array write
encoders (review 07 U10/U9), but the capability table still listed all three
as scalar-only, so every array node materialised read-only and a client write
was BadNotWritable before it reached the driver.

Rows added, each listing only what WriteAsync encodes end to end:
- AbCip: SInt/USInt/Int/UInt/DInt/UDInt/Real/Dt/LInt/ULInt/LReal, declared
  length, not a safetyTag. BOOL/STRING/Structure arrays stay read-only.
- AbLegacy: Int/AnalogInt on N/B/A, Long on L, Float on F (file-width match),
  plain <file><n>:<word> address, <= 256 elements; not /bit, .sub, indirect,
  S:/I:/O:, nor native PLC-5.
- TwinCAT: every codec element type, declared length; not a BOOL bit-in-word
  path.
Elements convert in all three encoders, so the rows never key on an exact
node DataType (ScadaBridge int[] -> Int16 stays writable); they leave out
only node types whose elements never convert (DateTime/String over numeric,
Boolean on AbLegacy, STRING under DateTime on TwinCAT: culture-dependent).

Tests: driver-level parity for each driver (every element type x node type
plus shape cases, against the real write path), the AbLegacy parity tests
un-skipped, Core.Abstractions row tests, a composer test (three drivers
writable, refused shapes read-only), and the existing AbCip negative cases
moved to a BOOL array. Docs: Uns.md table, per-driver docs, data-plane rules.

Refs #737 #738 #739

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 16:17:48 -04:00
Joseph Doherty d7c0135d0b docs(scripting): ctx.CancellationToken also fires on caller cancellation
Review m-6. The XML doc said the token is cancelled on timeout only.
ScriptRunGuard links it to the caller's token
(CreateLinkedTokenSource(ct)), so it is also cancelled on shutdown or
when the evaluating actor stops mid-run. The doc now says so.

Refs #731 #734
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 15:15:49 -04:00
Joseph Doherty 6636de1199 refactor(runtime): delete the per-value AttributeValuePublished message
It had no production sender: every driver data change is already a
batch, and the comms-loss fan was converted earlier. DependencyMuxActor
drops its per-value receive, DriverInstanceActor drops the record, and
DependencyMuxActorTests' 13 sends move to the ValuePublishes.Single
one-item batch (same semantics through the batch path). XML docs and
the living docs (DriverLifecycle, VirtualTags, ScriptEditor) are
reworded; historical plan docs are left as written.

Refs #731 #734
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 14:42:08 -04:00
Joseph Doherty d2cc071517 feat(scripting): expose the run token to scripts as ctx.CancellationToken
ScriptContext.CancellationToken is backed by an AsyncLocal that
ScriptEvaluator.RunAsync scopes around the compiled delegate, so it is
exactly the token ScriptRunGuard cancels on timeout. A polling script
can now end its own abandoned run and free the slot. AsyncLocal rather
than a field because the scripted-alarm engine reuses one context per
alarm: an orphan keeps seeing its own cancelled token. The scoping
entry point is internal (IVT to Core.Scripting) so a script cannot
replace its own token.

Editor parity: ScriptAnalysisService dot-completion now walks the
receiver's base chain (instance members only, stopping before
System.Object). Before this, a member declared only on ScriptContext
compiled and published but never completed. DiagnoseTests pins the
member as allow-listed; CompletionTests pins the completion.

Refs #731 #734
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 14:31:03 -04:00
Joseph Doherty 4615495f01 feat(scripting): bind the Scripting section node-wide and clamp its knobs
Program.cs binds ScriptingOptions from Scripting:* once, clamps every
numeric knob through ScriptingOptions.Sanitized (logging a Warning per
adjustment) and registers the one instance. It now reaches all three
script seams: RoslynVirtualTagEvaluator, the scripted-alarm engine
built in DriverHostActor (new trailing Props parameter, wired in
WithOtOpcUaRuntimeActors) and every Calculation driver (node options
as the base, per-driver config keys override one knob on a copy).

ScriptRunGuard sanitizes again in its ctor and computes the stuck
threshold with a saturating multiply, so an absurd
StuckOrphanQuarantineFactor can no longer throw OverflowException on
a refused run.

Refs #731 #734
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 14:24:53 -04:00
Joseph Doherty 7bcb6331ed Merge lane C: control plane, host, security (#733)
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 14:09:08 -04:00
Joseph Doherty a85d1c069a fix(scripting): quarantine a refusal behind a stuck orphan (fix round 2)
Ruling refinement on I1. Only timeouts are strikes, so a never-returning
while(true), which times out once and is then only refused, was never
quarantined, and that defeated E1. A refusal now quarantines immediately
when the orphan it was refused behind has been executing for longer than
ScriptingOptions.StuckOrphanQuarantineFactor x the script's timeout
(default 10, so 20 s at the 2 s default; 0 or less disables it). It uses
the same quarantine path: one Error, otopcua.script.quarantined with
reason=stuck, Bad, lifted on source change or redeploy. A young orphan
(a short overrun) is still a plain refusal.

The guard stamps the run's start (Stopwatch timestamp) when the pool
picks it up and clears it when the run really finishes.

Tests: the 30-trigger while(true) regression (paced) now ends
quarantined with reason "stuck", still with exactly one orphan and a
healthy sibling. Positive control: a 2x overrun is refused, not
quarantined, and evaluates again once the orphan completes. A factor of
0 disables the rule. Docs (ScriptEditor "Runtime safety", VirtualTags)
and the seam remarks are updated.

Refs #734

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 13:59:10 -04:00
Joseph Doherty 2adeacc655 fix(controlplane): keep the revision hash byte-identical to the pre-refactor composer
The one-snapshot refactor re-sorted every collection in memory with an ordinal comparer, while the old
composer's SQL ORDER BY used the database's case-insensitive collation; mixed-case keys therefore re-hashed
an unchanged configuration (spurious drift fleet-wide, a "new" revision on a no-op redeploy). The snapshot
factory now reads every composed table ORDER BY its natural key server-side and Compose serialises in the
order given. Pinned byte-for-byte against a verbatim replica of the old composer on the real SQL Server.

Refs #733
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 13:48:40 -04:00
Joseph Doherty ef2eebe6b6 fix(scripting): review minors: configured limit in summaries, dispose gate/CTS, validator, docs (fix round 1)
- ScriptLogRateLimiter.LimitPerWindow. The ScriptLogTopicSink and
  VirtualTagActor summaries now print the configured limit, not
  DefaultLimitPerWindow. Tests assert "limit N/window" for a non-default
  N.
- CalculationDriver.Dispose cancels, then takes _evalGate (bounded 2 s)
  and disposes the gate and _evalCts. The pump and timer ticks enter the
  gate through TryEnterEvalGateAsync, which stops cleanly once the
  driver is disposed. Test: Dispose with a 6 s runaway run in flight
  returns promptly, disposes both, and a late trigger is harmless.
- ScriptedAlarmEngine captures _shutdownToken once and disposes
  _shutdownCts in Dispose when every drained task has completed. A task
  stuck past the grace leaves the CTS to the GC. Lifecycle tests assert
  the disposal.
- DraftValidator: CalculationNoEffectiveTrigger is skipped for a
  change-triggered tag whose scriptId does not resolve. That case is
  already CalculationScriptMissing or CalculationScriptNotFound, and
  there are no reads to count. Both existing tests now assert the
  absence (red before the change).
- docs/VirtualTags.md: System.Threading is denied as a whole namespace,
  with an allow-list; the type list is now accurate (Unsafe,
  RuntimeHelpers, and the ForbiddenMembers on System.Type); the resource
  limits section covers the run guard and the allocation budget.
  docs/ScriptEditor.md: accurate deny-list and a new "Runtime safety"
  section covering timeout, refusal, quarantine after 3 timeouts,
  allocation budget, lifting, and rate-limit summaries that appear only
  on the source's next entry after a burst then quiet.

Refs #734

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 13:41:15 -04:00
Joseph Doherty 4d17b346c6 Merge branch 'master' into remed/lane-C 2026-10-22 13:31:03 -04:00
Joseph Doherty 6aa5edaf30 fix(scripting): only timeouts are quarantine strikes; alarm Bad annotation once per bucket change (fix round 1 I1, I3)
- I1 ScriptRunGuard: a run refused because the previous one is still
  executing is a Bad publish plus otopcua.script.run_refused, and no longer
  a quarantine strike. Only a timeout (and an allocation breach) counts;
  a refusal neither adds to nor resets the timeout streak; a completed run
  (value or throw) resets it. On a 1 Hz trigger with a 2 s budget a single
  4 s overrun is one timeout plus two refusals and must not quarantine.
  Tests updated across the guard, the alarm engine, the Calculation
  evaluator and the VT evaluator, plus
  Refusals_neither_count_toward_nor_reset_the_timeout_streak.
- I3 ScriptedAlarmEngine: the quality bucket is tracked only after the
  predicate completes (or in the inputs-not-ready path), so the tracked
  bucket is the last one annotated. A refused or quarantined predicate
  used to re-track the input bucket Good before the attempt and then flip
  it Bad, emitting QualityChanged on every push. The run-guard tests now
  count emissions (exactly 1 across N pushes, refused and quarantined
  cases), with a healthy sibling's dispatch count as the positive control
  that every push was processed. Both were red before the fix.

Refs #734

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 13:26:12 -04:00
Joseph Doherty 909b061d3a Merge branch 'master' into remed/lane-E 2026-10-22 10:48:41 -04:00
Joseph Doherty d8c39933ed Merge lane A: runtime driver lifecycle (#731)
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 10:44:22 -04:00
Joseph Doherty a01f5e6705 build: pin patched System.Security.Cryptography.* / SignalR to clear fresh-restore NuGet audit
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 10:38:07 -04:00
Joseph Doherty 1bf5ef916c feat(controlplane): deployment artifact retention on the admin singleton
Every deploy stored the whole gzip'd fleet snapshot in Deployment.ArtifactBlob forever (R03:1.2).
DeploymentRetentionActor (admin singleton, proxy-less) sweeps every Deployments:Retention:
IntervalMinutes (60): terminal rows (Sealed / PartiallyFailed / TimedOut) older than the newest
KeepSealed (50) and not referenced by a NodeDeploymentState started/applied within ReferencedDays
(30) get their blob EMPTIED — never deleted, never NULLed: the column stays NOT NULL and every
reader already treats zero bytes as "no artifact" (#485), so no schema migration and no reader
change. In-flight rows are never touched; MaxRowsPerSweep (200) bounds one sweep.

Refs #733

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 10:27:59 -04:00
Joseph Doherty 4d3fc9c816 fix(runtime): restart-safe alarm host, mux last-value replay, VT log rate limit, Calculation remediation (E4)
- R02:H1 ScriptedAlarmHostActor gains a factory Props
  (Func<(upstream, engine)>) so every incarnation builds and owns its own
  engine; a supervision restart no longer re-creates the actor around a
  disposed engine. The legacy instance-taking Props stays source-compatible
  and is now restart-safe in the weaker sense (PreRestart marks the stop as
  a restart, PostStop then detaches instead of disposing). DriverHostActor
  still spawns through the legacy overload (not owned by this lane — F3).
- R02:H3 OnAlarmCommand runs every engine op under a 10 s token linked to
  the actor's lifetime (DefaultCommandTimeout / Props commandTimeout) and
  logs a Warning on timeout instead of suspending the mailbox on a stalled
  store.
- R02:L3 DependencyMuxTagUpstreamSource.RetainOnly(loaded dep-ref union),
  called after every successful load.
- R02:P6 VirtualTagActor's per-failure ScriptLogEntry is rate-limited per
  tag (ScriptLogRateLimiter, 20/min + one summary); the Bad publish and the
  metric are untouched.
- R07:H6 DependencyMuxActor retains the last (value, status, ts) per
  ever-registered ref (through unregisters) and replays them in one batch to
  a RegisterInterest(ReplayRetained: true) — VirtualTagActor, the Calculation
  mux adapter and the alarm host opt in; the historization recorder does not
  (a replay there would record a stale sample per deploy). CalculationDriver
  records inputs regardless of _running so a replay landing before
  InitializeAsync still satisfies the change-gate.
- R07:P4 CalculationEvaluator negative-caches compile failures by source
  hash (one Roslyn attempt + one Warning per source until redeploy); the
  driver's script-log entry fires on the Good→Bad transition or a change of
  reason, matching the once-per-transition Bad publish.
- R07:H8 array results dedup structurally.
- R07:L2 ShutdownAsync drops the compiled scripts (collectible ALCs).
- R07:U5 DraftValidator rule CalculationNoEffectiveTrigger: a tag with no
  timer whose change trigger is off or whose script has no literal
  ctx.GetTag read can never evaluate.

Refs #734

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 10:27:49 -04:00
Joseph Doherty 6cbf763719 fix(alarms): engine cache prune + bounded dispose, source Warning, cached dead-letter depth, script-log rate limit (E3)
- R05:1/12 ScriptedAlarmEngine: _valueCache is cleared in LoadAsync (it is
  re-seeded for the referenced paths) so retired tags no longer accrete across
  deploys; OnUpstreamChange no longer writes the cache after Dispose.
- R05:3 ScriptedAlarmEngine.Dispose drains in-flight work for at most 5 s
  (DisposeDrainTimeout), then cancels it through a shutdown token every
  DrainDirtyAsync/ShelvingCheckAsync now runs on, logs a Warning and gives
  one second of grace — a stalled IAlarmStateStore.SaveAsync can no longer
  hang host shutdown. A save that completes inside the bound is still drained
  (positive control test).
- R05:6 ScriptedAlarmSource logs a throwing OnAlarmEvent subscriber at
  Warning (naming the alarm) instead of swallowing it.
- R05:7 LocalDbStoreAndForwardSink keeps a cached dead-letter counter in step
  with every dead-letter/revive/purge path and resyncs it with the queued
  counter on the same cadence; GetStatus no longer runs a COUNT(*) scan.
- R05:9 ScriptLogRateLimiter (20 per source per minute, fixed window, one
  summary entry naming the dropped count when the window rolls) behind
  ScriptLogTopicSink (key = script|vtag|alarm) and ScriptLogCompanionSink
  (key = script name).

Refs #734

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 10:17:30 -04:00
Joseph Doherty 2e9160317f feat(scripting): deny System.Threading, Type reflection entry points and RuntimeHelpers in the sandbox (E2)
R05:10 — the namespace deny-list covered System.Threading.Tasks but not
System.Threading, so SemaphoreSlim / Monitor / SpinWait / Mutex /
EventWaitHandle could park a script's pool thread past its budget (or touch a
system-global kernel object); System.Type.GetType(string) / GetMethod* /
InvokeMember and System.Runtime.CompilerServices.RuntimeHelpers resolved and
reach a forbidden type without naming it syntactically.

ForbiddenTypeAnalyzer now denies the whole System.Threading namespace with a
type-granular allow-list (CancellationToken, Interlocked, Volatile — the
sync-free primitives), adds a member deny-list for System.Type's reflection
entry points (GetType/GetMethod(s)/InvokeMember/GetProperty(ies)/GetField(s)/
GetMember(s)/GetConstructor(s)/GetEvent(s)/GetDefaultMembers; instance
object.GetType() stays allowed) and puts RuntimeHelpers on the type deny-list.
Thread/ThreadPool/Timer leave the type list — the prefix rule reaches them.

R05:11 — the allocation budget landed with E1's ScriptRunGuard
(Scripting:MaxAllocBytesPerRun, default 64 MB): sampled around each run,
breach quarantines. It is observation after the fact; a pre-emptive OOM guard
still needs an out-of-process runner (follow-up issue in the lane report).

The Monaco editor shares the analyzer, so DiagnoseTests pins every new form
as an OTSCRIPT_FORBIDDEN marker and every allow-listed form as clean.

Refs #734

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 06:45:03 -04:00
Joseph Doherty eb9269c337 feat(scripting): ScriptRunGuard quarantines runaway scripts across every seam (E1)
A timed-out script is abandoned, not stopped, and every seam re-ran it on the
next trigger, leaking one pool thread per trigger (R03:1.1, R05:2, R07:L1).
A shared ScriptRunGuard, keyed per script instance, now:

- refuses a run while that script's previous orphan is still executing
  (Bad "previous evaluation still running" + otopcua.script.run_refused);
- quarantines after 3 consecutive non-completions or an allocation-budget
  breach (sampled with GC.GetAllocatedBytesForCurrentThread; default 64 MB):
  no further dispatch, Bad quality, one Error, otopcua.script.quarantined,
  cleared on source change / redeploy / reset;
- starts the budget clock when the pool picks the run up, so starvation is
  no longer charged to the script (R07:P5), and cancels the evaluator token
  on timeout.

Wired into RoslynVirtualTagEvaluator, CalculationEvaluator (new async
EvaluateAsync; the driver's pump and timer ticks now await the run behind a
SemaphoreSlim gate) and ScriptedAlarmEngine (a non-completing predicate
holds state and annotates the condition BadInternalError). ScriptingOptions
(Scripting:MaxAllocBytesPerRun, Scripting:QuarantineAfterConsecutiveTimeouts)
carries the knobs; the Calculation driver config accepts the same two keys.

Tests: guard unit suite (incl. the 30-trigger runaway leaving one orphan with
a healthy sibling as positive control), per-seam refusal/quarantine/reset
tests. The S12 race test now uses one vtag id per loop: twelve concurrent
evaluations of ONE id is a shape production never produces and the guard
refuses by design.

Refs #734

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 06:39:43 -04:00
Joseph Doherty c6d4b14c93 feat(telemetry): wire TelemetryDial:CallTimeoutSeconds as the dial-establishment deadline (A5)
CallTimeoutSeconds was bound, defaulted and documented but consumed
nowhere. TelemetryDialSupervisor now arms a per-generation deadline on
every dial: a dial that has delivered no event by the deadline is
cancelled and treated as a transport failure (reconnect with a failure
streak). A live node replays its snapshots on subscribe, so this bites
only a dial that never connects (a black-holed host, where the socket
connect has no timeout). An established stream is deliberately not
bounded — the wire has no heartbeat, keepalive pings own its liveness.

Review ref: 02/U2.

Refs #731

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT