Commit Graph

24 Commits

Author SHA1 Message Date
Joseph Doherty beb1c583b1 fix(opcuaclient): #676 live gate A1 — a sustained closed connection is a definitive loss
Live gate A1 (docker-dev, opc-plc restart / SIGINT / kill): the fast path never fired —
a real process stop delivers no session status; the keep-alives report
BadSecureChannelClosed (0x80860000) once, then BadConnectionClosed (0x80AE0000)
interleaved with BadNoCommunication for the whole outage.

Reproduced in-process with TcpStallProxy.HardClose (reset every connection, refuse new
ones; server and session alive behind it): the identical sequence, and the SDK 1.5.378
session never opens a new connection on its own (48 s with the proxy accepting again,
zero attempts) — a closed channel cannot recover in place.

The driver now treats BadSecureChannelClosed/BadConnectionClosed as definitive on the
SECOND closed-channel keep-alive failure in one outage (a good keep-alive resets the
count), raising ConnectionLost ~1 keep-alive after the drop. BadNoCommunication /
BadRequestTimeout / BadNotConnected (stall/pause) stay with the watchdog; the stall test
still sees no ConnectionLost. New wire test (hard close + reopen ⇒ raised once, SDK never
reconnects, reinit brings the identical value back Good) and unit tests (sustained raises
once; a single blip that recovers does not) — all red on the previous code. Docs updated.
2026-10-11 12:34:52 -04:00
Joseph Doherty 27bf4826d6 fix(opcuaclient): #676 re-review — trailing read skips refs delivered to while in flight
1. A per-ref delivery counter (bumped under the delivery lock by every publish path) is
   captured before the trailing read is issued; a ref delivered to since is skipped.
   Without source timestamps the read's sample could not be ordered against a notification
   that landed mid-read, and publishing it regressed the node. Test injects the
   notification inside the mocked read, with and without a read source time (red before).
2. Delivery-lock comment corrected (it serialises across subscriptions, which the SDK
   dispatches on separate workers); PublishCommsLoss now publishes under the lock too.
3. CancelSessionWork cancels without disposing, so a keep-alive thread reading the old
   token cannot hit ObjectDisposedException.
2026-10-11 11:44:12 -04:00
Joseph Doherty 30a9d5f094 fix(opcuaclient): #676 review fix-ups (port-less rewrite, full reconcile, delivery lock, timers)
1. RewriteEndpointUrl keeps the advertised port when the configured URL names none
   (Uri.Port -1 would have sent the session to 4840); port-less + IPv6 tests.
2. The trailing re-read repairs any (value, status) difference that is not older than
   the last delivered value — Good->Bad/Uncertain included; a read without a source
   timestamp counts as newer; an equal source time with different content is published
   (repairs the replay guard's by-design equal-timestamp drop).
3. One driver-wide delivery lock makes decide+publish atomic across live notifications,
   the recovery read and the trailing read, so an older value can never land after a
   newer one (deterministic race test via a seam).
4. Known gap documented: a ConnectionLost raised while the host is not Connected is
   swallowed and that session falls back to the watchdog.
5. Only a SERVER-reported subscription loss raises ConnectionLost; the publishing-stall
   heuristic stays with the #527 watchdog.
6. Post-recovery timers run on Task.Delay(…, Clock, ct) with a session-work CTS
   cancelled on session release and dispose.
7. Replay summary at Information only when something was dropped (Debug otherwise);
   a re-arm reports the superseded window's drops and counts afresh.
8. DriverInstanceActor: AttachHostStatusSource doc comment restored; Reconnecting
   swallows a stray DisconnectObserved (test).
9. Stall wire test: 120 s session timeout, 3000-cycle subscription lifetime, one further
   bad keep-alive tick, 60 s headroom on the post-recovery waits (5/5 green).
2026-10-11 11:35:53 -04:00
Joseph Doherty fccffd0a0f feat(opcuaclient): #676 follow-ups — endpoint rewrite, stall wire test, fast definitive-loss recovery
- Endpoint rewrite: the driver now connects to the configured host AND port (scheme
  match, advertised path kept) instead of the server-advertised URL — fixes NAT/port-map
  upstreams and lets an in-test proxy carry the session (SDK SelectEndpoint rule).
- TcpStallProxy + OpcUaClientDriverStallWireTests: the in-place blip (#670) is now
  wire-tested on loopback — one Bad, frozen read stamp, same session, identical value
  republished Good, a post-recovery change arrives, no source-time regression after
  the SDK's late backlog flush.
- Defect found by that test, fixed: a change published right after a stall rode a
  Publish response the SDK timed out and never republished, leaving the node Good on
  the pre-change value indefinitely. New trailing reconcile read (Timeout +
  KeepAliveInterval after recovery) publishes any Good value newer than the last
  accepted one, through the replay guard's mark.
- IDriverConnectionLossSource (Core.Abstractions): opt-in definitive-loss signal.
  DriverInstanceActor attaches in PreStart / detaches in PostStop and turns a raise
  into a disconnect only while Connected. OpcUaClient raises once per session on
  keep-alive BadSessionIdInvalid/BadSessionClosed/BadSessionNotActivated/
  BadServerHalted (measured: the SDK never re-opens a halted channel) or a dropped
  subscription; ambiguous codes stay with the #527 watchdog.
- Replay guard: one Information summary per recovery when the window closes
  ("dropped N late notifications across M refs"), with a timer so quiet
  subscriptions log it too.
- ReconnectPeriod deleted (options, AdminUI form, docs, tests); stored configs that
  carry reconnectPeriod still parse in the factory, probe and browser.
- Docs: OpcUaClient.md, DriverLifecycle.md, driver-specs.md, CLAUDE.md.
2026-10-11 11:35:52 -04:00
Joseph Doherty 099bc1b6e0 fix(opcuaclient): #670 F2 re-gate — hold the replay guard for the whole window
The F2 live gate failed (10 value regressions over 4 blips): IsLateReplay
disarmed a ref on its first in-order notification, which arrives ~1 s after
recovery, while the SDK's late replay lands 4-6 s later. Equal source times
also passed, so a replay equal to the recovery read got through.

While the window is open each ref now carries a high-water mark (seeded at
arming, raised by the recovery read, advanced by every accepted notification);
a notification at or below it is dropped (equal included — OPC UA moves the
source timestamp on every value/status change). Null source time passes
without moving the mark. Window expiry still disarms entirely, so an upstream
clock step-back is never frozen outside the window. Arm/expiry serialised by a
lock so an expiry racing a re-arm cannot wipe fresh seeds.
2026-10-11 09:42:39 -04:00
Joseph Doherty 87e8aff786 fix(opcuaclient): scope the #670 F2 late-replay drop to the post-recovery window
The global 'never older than the last Good source time' rule froze a node
whenever an upstream clock stepped backwards (NTP correction, PLC clock
reset) until the clock caught up. The check is now a replay guard armed
only by a same-session recovery (keep-alive bad->good): per ref it holds
the last Good upstream source time (raised by the recovery read), a ref
disarms on its first in-order notification, and the whole guard expires
after max(30 s, 2x the longest subscription keep-alive window). Outside
it every notification is accepted. The steady-state tracker records the
LAST accepted time, not a high-water mark.
2026-10-11 09:15:51 -04:00
Joseph Doherty 99c13e4459 fix(opcuaclient): #670 live-gate follow-ups — historize the outage Bad, drop late replays
F1: the driver's outage BadNoCommunication carried the last Good sample's
source timestamp. The recorder historizes SourceTimestampUtc ??
ServerTimestampUtc, so the Bad landed on the Good row's (TagId,
SourceTimeUtc) key and the insert-if-absent historian dropped it - no
outage marker until the host's watchdog marker ~95 s in, none at all for
a short blip. Now stamped with the detection time (source + server), as
the host's comms-loss fan does.

F2: after a same-session recovery the SDK delivered a missed notification
seconds late with an older source time and the node regressed. A
notification older than the newest Good upstream source time for its ref
(notification or recovery read) is dropped and counted
(stale_notification_dropped); equal timestamps pass; the outage Bad never
moves the comparison; a re-initialise resets it.
2026-10-11 09:11:34 -04:00
Joseph Doherty b028322568 fix(opcuaclient): #670 review — subscription loss with a live session, stale recovery latch
M1: a subscription that dies while the session lives (outage longer than
the subscription lifetime but shorter than the session timeout) used to
end Healthy with fresh keep-alive stamps and frozen values. PublishError
BadNoSubscription / BadSubscriptionIdInvalid naming a tracked
subscription, or a tracked subscription whose SDK PublishingStopped
persists one more keep-alive window + 5 s across good keep-alives, now
declares it lost: Degraded, outage published once, and nothing advances
LastSuccessfulRead until the session is released, so the #527 watchdog
re-initialises and re-subscribes. Both detectors wire-tested.

M2: in-place recovery is bound to the session whose keep-alive recovered;
one overtaken by a re-initialise no longer re-arms the new session's
outage latch or degrades its health (ReadCoreAsync expectedSession).

L1 CAS health updates; L2 re-check before each recovery publish; L3 skip
CloseSession on a lost session; L4 SDK log forwarding rate-limited
(20/min); L5 per-driver SDK LoggerFactory disposed with the driver.
Wire test asserts the read stamp stays frozen while the server is down.
2026-10-11 08:41:27 -04:00
Joseph Doherty 2a8f9af5e4 fix(opcuaclient): upstream session loss goes Bad and recovers (#670)
A bad keep-alive now degrades health (LastSuccessfulRead preserved) and,
once per outage, publishes BadNoCommunication (value retained) for every
subscribed ref plus a quality-only annotation on subscribed alarm
conditions. Good keep-alives and data/event notifications advance
LastSuccessfulRead, so an idle-but-alive subscription never looks dead
to the #527 watchdog. A keep-alive that recovers on the same session
re-reads the Bad refs and republishes them Good; a session that does not
come back is recovered by the watchdog's ShutdownAsync + InitializeAsync
+ re-subscribe.

Deletes the SessionReconnectHandler wiring (it retried forever in SDK
1.5.378, cloned subscriptions the driver never re-tracked and kept health
Healthy), OnReconnectComplete, TryRearmReconnect and the reconnect_*
counters (new keepalive_recovered). Teardown of a lost session skips
wire deletes and bounds CloseSession. SDK warnings reach the driver log.
Wire test reworked: restart => Bad, then watchdog-style reinit => Good.
2026-10-11 08:27:04 -04:00
Joseph Doherty 48a80b5962 fix(alarms): atomic InactiveUnacknowledged + flagged Clear/Acknowledge first sight for OpcUaClient (#657)
After an OpcUaClient respawn an upstream inactive+unacked condition went out as
Retrigger+Clear (duplicate Activated+Cleared rows, Active flicker), and a
first-sight inactive+acked one as Unspecified (an Activated row for an inactive
alarm; a retained-Active host condition never cleared).

- New AlarmTransitionKind.InactiveUnacknowledged: one projection, rows only for
  what changed (Activated+Cleared from acked, Cleared from active+unacked, none
  when already inactive+unacked).
- OpcUaClient uses it for moves into inactive+unacked; first sight of an
  inactive condition is InactiveUnacknowledged or Clear+Acknowledge, flagged.
- Projector: a flagged Acknowledge on an already-acked condition writes no row.
- E2E tests through DriverHostActor.ForwardNativeAlarm (red-proven).

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-09 06:08:39 -04:00
Joseph Doherty 82750cccb9 Merge hw3-alarms (#656 atomic ActiveAcknowledged + re-statement flag for native alarms)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-09 00:14:47 -04:00
Joseph Doherty e138e39778 docs(alarms): #656 re-statement flag + ActiveAcknowledged kind (AlarmTracking, OpcUaClient, Galaxy, ScriptedAlarms, CLAUDE.md)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 23:43:09 -04:00
Joseph Doherty 67059e479f docs(#655): history is server-side only; rewrite OPC-009 and stale driver-history references
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 23:36:25 -04:00
Joseph Doherty 83ab123466 Merge b647-opcua-histstatus: OpcUaClient HistoryRead honours per-node StatusCode (#649)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:30:06 -04:00
Joseph Doherty b8c2136732 fix(opcuaclient): #649 review minors - CodeBits match, Bad-only exception ctor, BadNoData + Raw-resume tests, latent-impact docs
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:29:47 -04:00
Joseph Doherty 22e79112b6 fix(opcuaclient): HistoryRead honours the per-node StatusCode (BadAggregateNotSupported + other Bad) instead of returning empty data (#649)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:16:55 -04:00
Joseph Doherty dd05baedd6 refactor(opcuaclient): remove vestigial TargetNamespaceKind + UnsMappingTable (#648)
Nothing read the mapping table beyond the startup validator; v3 UNS projection is
explicit via UnsTagReference. Legacy keys in stored DriverConfig are ignored (pinned).
Reverts the docker-dev opc-plc seed workaround from fdee129f.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:14:37 -04:00
Joseph Doherty 8f5b265db8 fix(opcuaclient): native-alarm ConditionRefresh + transition table, branch, dedup and thread-safety fixes (#619 re-review)
Re-review of 3de2cc3b/454775c6:
- AlarmTransitions could not reach (inactive, unacked): (active,acked)->(inactive,unacked) emitted Clear
  (host stayed acked) and a first-seen cleared-unacked condition emitted nothing. The table is now total;
  an exhaustive test replays every (prior, target) pair through the projector's semantics.
- The per-RawPath read-compute-emit was a lock-free TryGetValue/set across SDK publish threads; it now runs
  under one lock with the projection and emission.
- Condition BRANCH events (non-null BranchId) were projected (flipping the trunk) and remembered as the ack
  target (acking the branch); they are dropped. BranchId is select clause 9.
- EventId is copied, not aliased from the decoded notification.
- An unchanged state re-emitted Unspecified; it now emits nothing unless message/severity changed (an
  Unspecified projects from the host projector's default after a redeploy reset it).
- Exact upstream severity rides OpcUaSeverity (#626) instead of being re-bucketed.
- ShutdownAsync no longer forgets the last-told state: a reinit re-subscribes the same set and the refresh
  would otherwise re-raise every acked alarm. A CHANGED set (host rebuilt) forgets it.

ConditionRefresh: called after the alarm event item is created, after an in-place reconnect (subscriptions
found on the new session by display name, since a recreate clones them) and on RefreshRequired. Refresh
markers are never projected. BadNotSupported/BadMethodInvalid/... logs once. Wire test: a condition already
active before subscribe is reported Raise; a release+resubscribe refresh re-raises nothing (falsified by
disabling the refresh call).

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:13:54 -04:00
Joseph Doherty 454775c67c fix(opcuaclient): derive AlarmTransitionKind from upstream ActiveState/AckedState (#619 review)
NativeAlarmProjector derives Active/Acked ONLY from AlarmEventArgs.Kind, and this driver
never set it - every routed event projected Unspecified, leaving the condition inactive+acked
(only Message/Severity moved). The live-gate expectation 'toggling Active as opc-plc cycles'
could not have passed. Select ActiveState/Id + AckedState/Id (two-element browse paths) and
emit the Kind sequence that moves the projector from the state last told to the host to the
event's (Raise+Acknowledge when a notification carries both).

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:04:48 -04:00
Joseph Doherty 3de2cc3ba8 fix(opcuaclient): alarm index survives namespace reorder; match condition node first; ack with real EventId (#619 review)
The alarm index was keyed on ns=N strings resolved once at subscribe time, while an
in-place SDK reconnect transfers the subscription without re-running it - a remote
namespace reorder silently orphaned every alarm tag. Keys are now nsu= on both sides.
Events match the authored nodeId against the event's ConditionId first, then its
SourceNode, so several conditions on one source can be authored 1:1. Acknowledge
passes the EventId of the event that named the remembered condition (paired, so node
and EventId can never come from different conditions) instead of an empty one.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 17:02:21 -04:00
Joseph Doherty d93491499d chore(docker-dev): seed OpcUaClient driver for opc-plc + doc native-alarm source semantics (#619)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 16:55:13 -04:00
Joseph Doherty 1219b7b13e fix(opcuaclient): review fixes - drop driver-side OperationLimits chunking (SDK batches), diagnostics as OTel counter, safe discovery selection, options validation at load (#273 #275 #276 #277 #278)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 14:55:53 -04:00
Joseph Doherty ba62022e88 feat(opcuaclient): subscription tuning, OperationLimits chunking, diagnostics counters, revocation options, DiscoveryUrl (#273 #275 #276 #277 #278)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 14:40:20 -04:00
Joseph Doherty f21883d607 docs(audit): G2 completeness — S7/TwinCAT/OpcUaClient/Historian overview pages 2026-06-03 16:14:40 -04:00