fix(opcuaclient): scope the #670 F2 late-replay drop to the post-recovery window
The global 'never older than the last Good source time' rule froze a node whenever an upstream clock stepped backwards (NTP correction, PLC clock reset) until the clock caught up. The check is now a replay guard armed only by a same-session recovery (keep-alive bad->good): per ref it holds the last Good upstream source time (raised by the recovery read), a ref disarms on its first in-order notification, and the whole guard expires after max(30 s, 2x the longest subscription keep-alive window). Outside it every notification is accepted. The steady-state tracker records the LAST accepted time, not a high-water mark.
This commit is contained in:
@@ -73,10 +73,12 @@ The session keep-alive (`KeepAliveInterval`, default 5 s) is the liveness signal
|
||||
the refs still Bad are re-read once and published Good (a server whose subscription survived does not resend an
|
||||
unchanged value, and a `(value, status)` dedup downstream lets the identical value through), alarm quality goes
|
||||
back Good and a `ConditionRefresh` re-reports anything missed. A notification that lands first wins over the read.
|
||||
A notification whose source time is OLDER than the newest Good upstream source time already published for its ref
|
||||
(notification or recovery read) is dropped — the SDK can deliver a missed one seconds late after a same-session
|
||||
recovery, which used to regress the node (live-gate F2). Equal timestamps pass (status-only changes); the outage
|
||||
Bad never moves the comparison; a re-initialise resets it.
|
||||
For a bounded **replay window** after such a recovery — max(30 s, 2 x the longest subscription keep-alive window) —
|
||||
a notification whose source time is OLDER than the ref's last Good upstream source time (raised by the recovery
|
||||
read) is dropped: the SDK was seen delivering a missed one 4–5 s late, which regressed the node (live-gate F2).
|
||||
A ref disarms on its first in-order (equal or newer) notification. Outside that window every notification is
|
||||
accepted whatever its timestamp, so an upstream clock that steps backwards (NTP, a PLC clock reset) never
|
||||
freezes a node. The outage Bad never moves the comparison; a re-initialise resets it.
|
||||
- **The session does not come back** (an upstream restart: the server forgot the session) ⇒ the driver stays
|
||||
`Degraded` with its read stamp frozen, which is exactly the #527 comms-loss watchdog's trip condition. After 90 s
|
||||
`DriverInstanceActor` runs `ShutdownAsync` + `InitializeAsync` (retried every 10 s while the server is down) and
|
||||
@@ -234,7 +236,7 @@ Session/publish events are published on the shared OTel meter as the counter
|
||||
`otopcua.driver.opcuaclient.events`, tagged `driver_instance` (the driver instance id) and `event` =
|
||||
`publish_response`, `notification` (items), `data_change`, `bad_status_value`, `publish_error`,
|
||||
`keepalive_miss`, `keepalive_recovered` (a bad keep-alive followed by a good one on the same session),
|
||||
`stale_notification_dropped` (an out-of-order late notification, see above). A climbing
|
||||
`stale_notification_dropped` (a late replay dropped inside the post-recovery window, see above). A climbing
|
||||
`keepalive_miss` / `keepalive_recovered` rate is the signature of a flapping upstream (`reconnect_*` were removed with
|
||||
the reconnect handler, #670). They are not part of `DriverHealth` or the
|
||||
`/hosts` panel.
|
||||
|
||||
@@ -24,7 +24,7 @@ internal sealed class OpcUaClientDiagnostics
|
||||
public const string KeepAliveMiss = "keepalive_miss";
|
||||
/// <summary>A keep-alive came back Good after a bad one on the same session (an in-place recovery, #670).</summary>
|
||||
public const string KeepAliveRecovered = "keepalive_recovered";
|
||||
/// <summary>A notification older than the newest Good source time already published for its ref was dropped (#670 F2).</summary>
|
||||
/// <summary>A late replayed notification (older than the ref's last Good source time) was dropped inside the post-recovery replay window (#670 F2).</summary>
|
||||
public const string StaleNotificationDropped = "stale_notification_dropped";
|
||||
|
||||
private readonly string _driverInstanceId;
|
||||
|
||||
@@ -295,14 +295,32 @@ public sealed class OpcUaClientDriver : IDriver, ITagDiscovery, IReadable, IWrit
|
||||
/// <summary>#670 — the last value delivered per subscribed RawPath, so an outage can publish
|
||||
/// <c>BadNoCommunication</c> with the value retained (the same shape the host's own comms-loss fan uses).</summary>
|
||||
/// <summary>
|
||||
/// #670 follow-up F2 — per RawPath, the newest SOURCE timestamp (ticks) of a Good value that came from the
|
||||
/// upstream (a notification or the recovery read). A notification older than it is a late replay — the SDK can
|
||||
/// deliver a missed notification seconds after a same-session recovery — and is dropped rather than regressing
|
||||
/// the node. The driver's own outage Bad never writes it (its stamp is the detection time, not upstream data).
|
||||
/// #670 follow-up F2 — per RawPath, the source time (ticks) of the last Good value ACCEPTED from upstream (a
|
||||
/// notification, or the recovery read). Last, not max: in steady state it simply follows the upstream clock,
|
||||
/// so a clock that steps backwards is tracked rather than remembered as a high-water mark. It only seeds the
|
||||
/// replay guard below; nothing is ever dropped against it outside that guard's window.
|
||||
/// </summary>
|
||||
private readonly System.Collections.Concurrent.ConcurrentDictionary<string, long> _lastGoodSourceTicks =
|
||||
new(StringComparer.Ordinal);
|
||||
|
||||
/// <summary>
|
||||
/// #670 follow-up F2 — the REPLAY guard. Armed only by a same-session recovery (keep-alive bad→good), when the
|
||||
/// SDK was observed delivering a missed notification seconds late with an older source time. Per ref it holds
|
||||
/// the newest Good upstream source time at arming (raised by the recovery read); a notification older than it
|
||||
/// is dropped. A ref disarms on its first in-order notification, and the whole guard expires at
|
||||
/// <see cref="_replayGuardUntilTicks"/>. Outside it every notification is accepted whatever its timestamp — a
|
||||
/// global "never go backwards" rule would freeze a node for as long as an upstream clock that stepped back
|
||||
/// (NTP correction, a PLC with a reset clock) takes to catch up.
|
||||
/// </summary>
|
||||
private readonly System.Collections.Concurrent.ConcurrentDictionary<string, long> _replayGuard =
|
||||
new(StringComparer.Ordinal);
|
||||
|
||||
/// <summary>Clock ticks at which the replay guard expires (0 = never armed).</summary>
|
||||
private long _replayGuardUntilTicks;
|
||||
|
||||
/// <summary>Floor of the replay-guard window; the live gate saw the late replay 4–5 s after recovery.</summary>
|
||||
private static readonly TimeSpan ReplayGuardMinimum = TimeSpan.FromSeconds(30);
|
||||
|
||||
private readonly System.Collections.Concurrent.ConcurrentDictionary<string, DataValueSnapshot> _lastValues =
|
||||
new(StringComparer.Ordinal);
|
||||
|
||||
@@ -995,6 +1013,8 @@ public sealed class OpcUaClientDriver : IDriver, ITagDiscovery, IReadable, IWrit
|
||||
// previous connection's value bookkeeping applies to them.
|
||||
_lastValues.Clear();
|
||||
_lastGoodSourceTicks.Clear();
|
||||
_replayGuard.Clear();
|
||||
Interlocked.Exchange(ref _replayGuardUntilTicks, 0);
|
||||
_awaitingRecovery.Clear();
|
||||
// #619 re-review: the last-told alarm states (and ack targets) deliberately SURVIVE a shutdown. A
|
||||
// ReinitializeAsync (comms-loss watchdog / Force Reconnect) is followed by the host re-subscribing the
|
||||
@@ -1734,14 +1754,13 @@ public sealed class OpcUaClientDriver : IDriver, ITagDiscovery, IReadable, IWrit
|
||||
StatusCode: dv.StatusCode.Code,
|
||||
SourceTimestampUtc: dv.SourceTimestamp == DateTime.MinValue ? null : dv.SourceTimestamp,
|
||||
ServerTimestampUtc: dv.ServerTimestamp == DateTime.MinValue ? DateTime.UtcNow : dv.ServerTimestamp);
|
||||
// F2: never let a late, older notification regress the node. Equal timestamps pass (a status-only change).
|
||||
if (snapshot.SourceTimestampUtc is { } src
|
||||
&& _lastGoodSourceTicks.TryGetValue(fullRef, out var newest) && src.Ticks < newest)
|
||||
// F2: inside the post-recovery replay window only, a late OLDER notification must not regress the node.
|
||||
if (IsLateReplay(fullRef, snapshot.SourceTimestampUtc, out var newest))
|
||||
{
|
||||
_diag.Record(OpcUaClientDiagnostics.StaleNotificationDropped);
|
||||
_logger.LogDebug(
|
||||
"OpcUaClientDriver '{DriverInstanceId}': dropped a late notification for {Ref} (source {Source:O} is " +
|
||||
"older than the newest Good source {Newest:O}).", _driverInstanceId, fullRef, src,
|
||||
"OpcUaClientDriver '{DriverInstanceId}': dropped a late replayed notification for {Ref} after a recovery " +
|
||||
"(source {Source:O} is older than {Newest:O}).", _driverInstanceId, fullRef, snapshot.SourceTimestampUtc,
|
||||
new DateTime(newest, DateTimeKind.Utc));
|
||||
return;
|
||||
}
|
||||
@@ -1751,11 +1770,48 @@ public sealed class OpcUaClientDriver : IDriver, ITagDiscovery, IReadable, IWrit
|
||||
OnDataChange?.Invoke(this, new DataChangeEventArgs(handle, fullRef, snapshot));
|
||||
}
|
||||
|
||||
/// <summary>#670 F2 — remember the newest Good upstream source time for <paramref name="fullRef"/>.</summary>
|
||||
/// <summary>#670 F2 — remember the last accepted Good upstream source time for <paramref name="fullRef"/>.</summary>
|
||||
private void RecordUpstreamGood(string fullRef, DataValueSnapshot snapshot)
|
||||
{
|
||||
if (snapshot.SourceTimestampUtc is not { } src || !StatusCode.IsGood(snapshot.StatusCode)) return;
|
||||
_lastGoodSourceTicks.AddOrUpdate(fullRef, src.Ticks, (_, prior) => Math.Max(prior, src.Ticks));
|
||||
_lastGoodSourceTicks[fullRef] = src.Ticks;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// #670 F2 — true when the replay guard is live for <paramref name="fullRef"/> and <paramref name="source"/> is
|
||||
/// older than its armed time. An in-order (equal or newer) notification disarms the ref; an expired window
|
||||
/// disarms everything.
|
||||
/// </summary>
|
||||
private bool IsLateReplay(string fullRef, DateTime? source, out long newest)
|
||||
{
|
||||
newest = 0;
|
||||
if (source is not { } src || _replayGuard.IsEmpty) return false;
|
||||
if (Clock.GetUtcNow().UtcDateTime.Ticks >= Interlocked.Read(ref _replayGuardUntilTicks))
|
||||
{
|
||||
_replayGuard.Clear();
|
||||
return false;
|
||||
}
|
||||
if (!_replayGuard.TryGetValue(fullRef, out newest)) return false;
|
||||
if (src.Ticks < newest) return true;
|
||||
_replayGuard.TryRemove(fullRef, out _);
|
||||
return false;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// #670 F2 — arm the replay guard on a same-session recovery: every ref with a known Good upstream source time,
|
||||
/// for max(30 s, 2 × the longest tracked subscription keep-alive window).
|
||||
/// </summary>
|
||||
private void ArmReplayGuard(DateTime now)
|
||||
{
|
||||
_replayGuard.Clear();
|
||||
foreach (var kv in _lastGoodSourceTicks) _replayGuard[kv.Key] = kv.Value;
|
||||
var window = ReplayGuardMinimum;
|
||||
foreach (var sub in _subscriptions.Values.Select(r => r.Subscription))
|
||||
{
|
||||
var keepAliveWindow = TimeSpan.FromMilliseconds(sub.CurrentPublishingInterval * (double)sub.CurrentKeepAliveCount);
|
||||
if (keepAliveWindow * 2 > window) window = keepAliveWindow * 2;
|
||||
}
|
||||
Interlocked.Exchange(ref _replayGuardUntilTicks, (now + window).Ticks);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
@@ -2623,6 +2679,7 @@ public sealed class OpcUaClientDriver : IDriver, ITagDiscovery, IReadable, IWrit
|
||||
UpdateHealth(_ => new DriverHealth(DriverState.Healthy, now, null));
|
||||
// A fresh grace: every subscription reports stopped right after an outage until its next message.
|
||||
Interlocked.Exchange(ref _publishingStoppedSinceTicks, 0);
|
||||
ArmReplayGuard(now);
|
||||
_diag.Record(OpcUaClientDiagnostics.KeepAliveRecovered);
|
||||
_logger.LogInformation(
|
||||
"OpcUaClientDriver '{DriverInstanceId}': upstream keep-alive recovered on the same session; " +
|
||||
@@ -2775,6 +2832,9 @@ public sealed class OpcUaClientDriver : IDriver, ITagDiscovery, IReadable, IWrit
|
||||
if (!_awaitingRecovery.TryRemove(refs[i], out _)) continue; // a notification got there first
|
||||
_lastValues[refs[i]] = results[i];
|
||||
RecordUpstreamGood(refs[i], results[i]);
|
||||
// The read is upstream data published inside the replay window: a replay older than it is late too.
|
||||
if (results[i].SourceTimestampUtc is { } readAt && StatusCode.IsGood(results[i].StatusCode))
|
||||
_replayGuard.AddOrUpdate(refs[i], readAt.Ticks, (_, prior) => Math.Max(prior, readAt.Ticks));
|
||||
foreach (var rs in _subscriptions.Values)
|
||||
if (rs.ItemHandlers.Any(p => RefOf(p.Item) == refs[i]))
|
||||
RaiseDataChange(new DataChangeEventArgs(rs.Handle, refs[i], results[i]));
|
||||
|
||||
+78
-10
@@ -496,13 +496,60 @@ public sealed class OpcUaClientSessionLossTests
|
||||
bad.ServerTimestampUtc.ShouldBe(clock.Now.UtcDateTime);
|
||||
}
|
||||
|
||||
private static void SetupReadAt(Mock<ISession> session, object value, DateTime sourceTime) =>
|
||||
session.Setup(s => s.ReadAsync(
|
||||
It.IsAny<RequestHeader>(), It.IsAny<double>(), It.IsAny<TimestampsToReturn>(),
|
||||
It.IsAny<ReadValueIdCollection>(), It.IsAny<CancellationToken>()))
|
||||
.ReturnsAsync(new ReadResponse
|
||||
{
|
||||
ResponseHeader = new ResponseHeader(),
|
||||
Results = [new DataValue(new Variant(value), StatusCodes.Good, sourceTime, sourceTime)],
|
||||
DiagnosticInfos = [],
|
||||
});
|
||||
|
||||
/// <summary>Drives a same-session outage + recovery (bad → good keep-alive) and waits for the recovery read.</summary>
|
||||
private static async Task RecoverInPlaceAsync(OpcUaClientDriver drv)
|
||||
{
|
||||
drv.RaiseKeepAliveForTest(StatusCodes.BadNoCommunication);
|
||||
drv.RaiseKeepAliveForTest(StatusCodes.Good);
|
||||
await drv.RecoveryTaskForTest;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// #670 follow-up F2 (live gate): after a same-session recovery the SDK delivered one notification late with
|
||||
/// an OLDER source time, and the node regressed to it. A notification older than the last Good source time
|
||||
/// published for its ref is dropped; an equal one (a status-only change) and a newer one pass.
|
||||
/// an OLDER source time, and the node regressed to it. Inside the post-recovery replay window an older
|
||||
/// notification is dropped; an equal one (a status-only change) passes and disarms the ref, after which the
|
||||
/// ref is back to accepting anything.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public void A_notification_older_than_the_last_good_source_time_is_dropped()
|
||||
public async Task After_a_recovery_a_late_older_notification_is_dropped_until_the_ref_is_back_in_order()
|
||||
{
|
||||
var (drv, session, clock) = NewConnectedDriver();
|
||||
using var _ = drv;
|
||||
var handle = drv.AddSubscriptionForTest([SpeedRef]);
|
||||
var t0 = clock.Now.UtcDateTime;
|
||||
drv.DeliverNotificationForTest(handle, SpeedRef, Good(668, t0.AddSeconds(2)));
|
||||
SetupReadAt(session, 668, t0.AddSeconds(2));
|
||||
await RecoverInPlaceAsync(drv);
|
||||
var seen = new List<DataChangeEventArgs>();
|
||||
drv.OnDataChange += (_, e) => seen.Add(e);
|
||||
|
||||
drv.DeliverNotificationForTest(handle, SpeedRef, Good(667, t0.AddSeconds(1))); // late replay
|
||||
drv.DeliverNotificationForTest(handle, SpeedRef,
|
||||
new DataValue(new Variant(668), StatusCodes.UncertainLastUsableValue, t0.AddSeconds(2), t0.AddSeconds(2))); // same ts, status-only
|
||||
drv.DeliverNotificationForTest(handle, SpeedRef, Good(669, t0.AddSeconds(3)));
|
||||
drv.DeliverNotificationForTest(handle, SpeedRef, Good(665, t0)); // disarmed: accepted
|
||||
|
||||
seen.Select(e => e.Snapshot.Value).ShouldBe(new object[] { 668, 669, 665 });
|
||||
seen[0].Snapshot.StatusCode.ShouldBe((uint)StatusCodes.UncertainLastUsableValue);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Coordinator review of F2: with no recovery in play, an upstream clock that steps BACKWARDS (NTP correction,
|
||||
/// a PLC with a reset clock) must not freeze the node — every notification is published, whatever its time.
|
||||
/// </summary>
|
||||
[Fact]
|
||||
public void In_steady_state_a_clock_step_backwards_still_publishes()
|
||||
{
|
||||
var (drv, _, clock) = NewConnectedDriver();
|
||||
using var _ = drv;
|
||||
@@ -511,14 +558,35 @@ public sealed class OpcUaClientSessionLossTests
|
||||
var seen = new List<DataChangeEventArgs>();
|
||||
drv.OnDataChange += (_, e) => seen.Add(e);
|
||||
|
||||
drv.DeliverNotificationForTest(handle, SpeedRef, Good(668, t0.AddSeconds(2)));
|
||||
drv.DeliverNotificationForTest(handle, SpeedRef, Good(667, t0.AddSeconds(1))); // late replay
|
||||
drv.DeliverNotificationForTest(handle, SpeedRef,
|
||||
new DataValue(new Variant(668), StatusCodes.UncertainLastUsableValue, t0.AddSeconds(2), t0.AddSeconds(2))); // same ts, status-only
|
||||
drv.DeliverNotificationForTest(handle, SpeedRef, Good(669, t0.AddSeconds(3)));
|
||||
drv.DeliverNotificationForTest(handle, SpeedRef, Good(1, t0.AddHours(1)));
|
||||
drv.DeliverNotificationForTest(handle, SpeedRef, Good(2, t0)); // clock stepped back an hour
|
||||
drv.DeliverNotificationForTest(handle, SpeedRef, Good(3, t0.AddSeconds(1)));
|
||||
|
||||
seen.Select(e => e.Snapshot.Value).ShouldBe(new object[] { 668, 668, 669 });
|
||||
seen[1].Snapshot.StatusCode.ShouldBe((uint)StatusCodes.UncertainLastUsableValue);
|
||||
seen.Select(e => e.Snapshot.Value).ShouldBe(new object[] { 1, 2, 3 });
|
||||
}
|
||||
|
||||
/// <summary>The replay guard is bounded in time: once its window has passed, an older notification is accepted
|
||||
/// even for a ref that never saw an in-order one.</summary>
|
||||
[Fact]
|
||||
public async Task The_replay_guard_expires()
|
||||
{
|
||||
var (drv, session, clock) = NewConnectedDriver();
|
||||
using var _ = drv;
|
||||
var handle = drv.AddSubscriptionForTest([SpeedRef]);
|
||||
var t0 = clock.Now.UtcDateTime;
|
||||
drv.DeliverNotificationForTest(handle, SpeedRef, Good(10, t0.AddSeconds(5)));
|
||||
SetupReadAt(session, 10, t0.AddSeconds(5));
|
||||
await RecoverInPlaceAsync(drv);
|
||||
var seen = new List<DataChangeEventArgs>();
|
||||
drv.OnDataChange += (_, e) => seen.Add(e);
|
||||
|
||||
clock.Advance(TimeSpan.FromSeconds(29));
|
||||
drv.DeliverNotificationForTest(handle, SpeedRef, Good(9, t0));
|
||||
seen.ShouldBeEmpty("still inside the 30 s window");
|
||||
|
||||
clock.Advance(TimeSpan.FromSeconds(2));
|
||||
drv.DeliverNotificationForTest(handle, SpeedRef, Good(8, t0));
|
||||
seen.ShouldHaveSingleItem().Snapshot.Value.ShouldBe(8);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
|
||||