The parameter was retained only for signature stability after the
EfAlarmConditionStateStore fallback that consumed it was retired. It is
removed from Props, the constructor and the positional Props.Create
forwarding list together, and from its one caller in
WithOtOpcUaRuntimeActors. No test passed it.
Refs #731#734
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
DriverHostActor now tells the mux SourceRemoved(driverInstanceId)
wherever a driver object ends: StopChild (deploy removal and the stop
half of a config-change respawn) and an operator Restart. It is not
sent on a supervision restart, which re-uses the same driver. Before
this nothing sent it, so a removed driver's last Good stayed in the
mux and replayed to the next replay-opting subscriber as current.
DriverHostActorSourceRemovedTests drives a real mux with two real
driver children: after a deploy drops DI-1 only DI-2's value replays
(positive control: both replay before the removal), and a supervision
restart of DI-1 leaves its value replayable.
Residual (documented on EvictRetainedValues): a burst the old child
enqueued just before it stopped can still be forwarded after the
eviction; the next publish, a comms-loss fan or the grace sweep
bounds it.
Refs #731#734
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
F10 follow-through: removing IDisposable outright broke a synchronous
drv.Dispose() call site outside this lane (Runtime.Tests
AbCipAlmaNativeAlarmEndToEndTests). The sync Dispose() is back, but it starts
the same teardown as DisposeAsync and returns instead of parking the caller on
DisposeAsync().AsTask().GetAwaiter().GetResult(); a background fault is
logged. The runtime still takes the IAsyncDisposable path (preferred, never
both).
Refs #737
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Review 07 P7 (High): reads walked every reference of every device serially
with no backoff, so a dead device cost Timeout per tag per poll (50 tags x 2 s
= 100 s) and starved every healthy device long enough to trip the comms-loss
watchdog against a reachable one.
- ReadAsync buckets references by device and reads up to 8 devices
concurrently; each device's tags are still read in order.
- Each device has a ConnectionBackoff (1 s doubling to 30 s). Two consecutive
comms faults mark it down: the rest of that pass and every later pass fail
fast with BadCommunicationError and touch no wire until the window expires or
any answer (data path or probe) resets it. One timing-out tag does not
blacken its answering siblings.
- Cold connects are single-flight per device (ConnectGate), replacing the
per-key creation locks; a cached handle never touches the gate.
- A status/exception proving the device ANSWERED with a deterministic refusal
(not found, not allowed, out of bounds, type/size mismatch) is per-tag Bad,
keeps its handle, warns once per tag and advances LastSuccessfulRead instead
of evicting and degrading. Writes classify the same way.
- Health is written once per read: Degraded if any device faulted, Healthy if
anything read Good, LastSuccessfulRead advanced when any device answered.
Adds an env-gated ab_server case with a blackholed sibling device.
Refs #738
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
DriverHostActor now hands ScriptedAlarmHostActor an engine factory
instead of a pre-built engine, so every incarnation (a supervision
restart included) builds, owns and disposes its own upstream + engine.
The legacy overload was already restart-safe in the detach sense, so
this is hygiene rather than a live hole; the factory path is the one
ScriptedAlarmHostActorRestartTests covers end to end. The closure
captures locals only and carries the node-wide ScriptingOptions.
Refs #731#734
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
P11: AbCipUdtReadPlanner called AbCipUdtMemberLayout.TryBuild(parent.Members)
for every member reference on every poll - O(members^2) per parent per tick,
a dictionary allocation each time. GetOrBuild caches the layout (including a
"not groupable" verdict) in a ConditionalWeakTable keyed by the member list's
identity, which is immutable for the life of the tag table; a re-init's new
lists replace the entries and the old ones are collected with them.
Refs #737
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
ScriptContext.CancellationToken is backed by an AsyncLocal that
ScriptEvaluator.RunAsync scopes around the compiled delegate, so it is
exactly the token ScriptRunGuard cancels on timeout. A polling script
can now end its own abandoned run and free the slot. AsyncLocal rather
than a field because the scripted-alarm engine reuses one context per
alarm: an orphan keeps seeing its own cancelled token. The scoping
entry point is internal (IVT to Core.Scripting) so a script cannot
replace its own token.
Editor parity: ScriptAnalysisService dot-completion now walks the
receiver's base chain (instance members only, stopping before
System.Object). Before this, a member declared only on ScriptContext
compiled and published but never completed. DiagnoseTests pins the
member as allow-listed; CompletionTests pins the completion.
Refs #731#734
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
C1 (critical): B6 computes the plan off the pinned thread while B1 made writes
non-creating, so a value/status/alarm write for a node the in-flight plan adds
was skipped, and change-driven drivers never republish it (BadWaitingForInitialData
indefinitely; on a full rebuild every re-subscribe value landed on discarded
nodes). OpcUaPublishActor now applies writes immediately AND remembers the
latest per (realm, id) while a plan is in flight or queued (value+status
compose; alarm state/quality coalesce to the latest, which the node's delta
gate makes inert on an existing condition), replays it after each apply before
answering, and drops it once the pipeline is idle. Bounded (250k keys by
default; beyond it new keys are not held, logged once).
I2: the data-plane-authority parse runs in its own try inside the plan task; a
throw is logged and never degrades the address-space apply.
I3: the SDK's DeleteMonitoredItems releases an item's component-cache
reference on a Good delete; a tombstoned item's reference was already
released, so the delete took one from the re-created node's entry. Released
items are remembered and the orphan delete takes one back first. Event items
never held a reference (EventManager + SubscribeToEvents), so the three
event-item releases are gone.
I4: direct tests for the HistoryUpdate override's per-request updater check
and the HistoryReadEvents override's source guard (both reached by restoring
the bit after a reset - the B7 race window); fixed the false remark.
Minors: the MaterialiseAlarmCondition kind-swap tombstones the dropped
instance; a bytes-less rebuild arriving mid-plan queues behind it (replies in
order); a PlanReady/PlanFailed from a previous actor incarnation is ignored and
its requester answered degraded; the tie-cluster end bound of an uncapped read
fits against the backend ceiling (defence in depth - guarded by a sweep test);
the lock-time benchmark stays in the default run, headroom noted.
Refs #732
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
U10 (user decision: implement array encode now): config, the AdminUI and
discovery all advertised array tags Operate-writable, but both runtimes encoded
a scalar - an int[] threw InvalidCastException (BadTypeMismatch AND Degraded),
a scalar wrote element 0 natively, and libplctag re-sent its whole last-read
buffer with element 0 patched (stale elements 1..n-1).
- AbCipArrayCodec encodes count elements little-endian at the element width,
CONVERTING each element (ScadaBridge writes int[] to INT arrays; overflow is
BadOutOfRange, unconvertible BadTypeMismatch, both before anything is sent).
- The driver checks the shape before any runtime exists: not a list ->
BadTypeMismatch, length != elementCount -> BadOutOfRange, BOOL/STRING/
structure element types -> BadNotSupported; and, before sending, a controller
buffer that is not width x count -> BadTypeMismatch. Refusals warn once and
write no health.
- Native: ONE Write Tag of count elements with the controller's type code (the
client fragments a large one); libplctag: the codec's bytes copied into the
elem_count-sized buffer, refused TooSmall if it does not fit.
- IAbCipTagRuntime.EncodeArray (default: NotSupportedException).
Real-controller proof is a hardware userGate (see the lane report recipe).
Refs #737
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
U11: a scalar BOOL authored over Bits[n] requested element n and decoded
"any of bits 0-7 of the reply set", so Bits[n] read Good with the subscript
ignored. A Logix BOOL array is stored as DWORDs (0xD3) and its element segment
addresses them, so the native runtime now requests DWORD n / 32 and decodes bit
n % 32 when the controller answers 0xD3 (a plain BOOL reply still decodes its
byte). libplctag exposes no type code and so cannot say which DWORD it read: a
4-byte reply for such a tag is refused BadNotSupported (warned once) instead of
publishing a wrong value as Good. Real-controller proof is a hardware gate.
Refs #737
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Applies the driver-lane health contract to the value path. Every non-Good read status used
to write Degraded on every poll, so one vacant macro (BadNoData), one EW_NUMBER address
(BadOutOfRange) or one fractional macro on an integer tag made a reachable CNC look sick
forever. Now:
- a comms-class status (BadCommunicationError / BadInternalError (EW_HANDLE) / BadTimeout)
still degrades, with LastSuccessfulRead preserved;
- any other non-Good status is a refusal: the tag reads Bad, one Warning is logged per tag
(re-armed when it next reads Good, cleared at init), driver state is untouched, and
LastSuccessfulRead advances because the CNC answered (CAS, since devices now read
concurrently);
- a write refused with NotSupportedException no longer degrades the driver.
Refs #740
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The poll engine already builds a per-cycle batch; TwinCAT now forwards it as
OnDataChangeBatch, so DriverInstanceActor gets one message per poll cycle
instead of one per changed tag. Because the actor subscribes ONLY the batch
event of a batch-capable driver, every native-path data change (pushes, the
BadNodeIdUnknown / refusal / unavailable snapshots) is raised through a single
RaiseDataChange that fires both the per-tag event and a fresh one-item batch.
Refs #739
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Review 07 U10 (user decision: implement array encode now). Both runtimes
encoded a scalar for an array tag: an int[] threw InvalidCastException into
BadTypeMismatch + Degraded, a scalar wrote element 0 natively, and libplctag's
SetInt32(0, ..) re-sent the stale last-read buffer for elements 1..n-1.
IAbLegacyTagRuntime gains EncodeArray; both runtimes write every element at
the element width (Int/AnalogInt 2 bytes, Long/Float 4). The driver converts
the written value before any runtime exists: each element is converted, not
exact-matched (ScadaBridge writes int[] to Int16 nodes), a length other than
the tag's element count is BadOutOfRange, an overflowing element is
BadOutOfRange, a non-array or non-numeric payload is BadTypeMismatch, and a Bit
array (bit-packed words; an encode would clobber neighbour bits) is
BadNotSupported. None of these touch health or the wire. Adds an env-gated
ab_server round trip for an N-file array write.
Refs #738
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Program.cs binds ScriptingOptions from Scripting:* once, clamps every
numeric knob through ScriptingOptions.Sanitized (logging a Warning per
adjustment) and registers the one instance. It now reaches all three
script seams: RoslynVirtualTagEvaluator, the scripted-alarm engine
built in DriverHostActor (new trailing Props parameter, wired in
WithOtOpcUaRuntimeActors) and every Calculation driver (node options
as the base, per-driver config keys override one knob on a copy).
ScriptRunGuard sanitizes again in its ctor and computes the stuck
threshold with a saturating multiply, so an absurd
StuckOrphanQuarantineFactor can no longer throw OverflowException on
a refused run.
Refs #731#734
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
- Device and tag tables are build-and-swap: InitializeAsync builds a fresh
generation and publishes it by one swap under a lifecycle lock, then
releases the replaced generation; teardown swaps in empty tables. A
retained poll loop never sees a table mid-Clear (it used to read
_tagsByRawPath while a re-init only ever added to it), and each device
set is released by exactly one caller.
- A lifecycle generation makes an InitializeAsync overtaken by a shutdown
(or a newer init) release what it built instead of installing it - the
Lane A abandoned-init-overlaps-shutdown case.
- ShutdownAsync joins all probe loops together within 2 s (it awaited each
unbounded - a probe wedged in the blocking ADS Connect hung the actor's
teardown) in parallel with the poll-engine dispose, the whole bounded at
4.5 s; DisposeAsync may run concurrently and returns at once. A connect
that completes on a released device disposes its client.
- Releasing a generation disposes its native registrations, so a direct
re-init no longer leaves live notifications bound to dead DeviceStates.
- Connect gates and RMW semaphores are no longer disposed under in-flight
users (no kernel handle is ever allocated); a fault on a released device
is not recorded as driver health.
- The notification channel counts DropWrite overflows
(ITwinCATClient.DroppedNotificationCount); the probe tick warns with the
delta. A queued value whose registration was disposed is purged in the
client dispatch loop and dropped driver-side for any client.
Refs #739
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
H19: Format/InvalidCast/Overflow on a client value never touched the wire but
latched Degraded; a good write set Healthy and so undid a Degraded the poll
loop had just recorded for other tags (the batch read path is worst-wins for
exactly this reason).
- The three conversion failures map to BadTypeMismatch/BadOutOfRange with a
once-per-tag Warning and no health write (AbLegacy's rule).
- A good write (scalar or bit RMW) advances LastSuccessfulRead only - the
device answered - and leaves the state alone.
- A write comms fault (thrown, or a non-refusal status word, which used to
write no health at all) is Degraded with LastSuccessfulRead preserved and
never downgrades Faulted.
Refs #737
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
ParseAlarms took the 76-byte vendor layout whenever Length % 76 == 0, so a legacy 80-byte
reply of exactly 19 records (1,520 B = 20 x 76) decoded as 20 garbage vendor records.
The response block carries no record count (its 16-byte header is length/class/path/
command/rc/payload length), so the layout is chosen from what is known: the record count
the request asked for (a reply never holds more), then each layout's field invariants on
every record. For legacy records, the int32 type/axis/length must fit a short and the
length must be at most 64. For vendor records, the i16 length must be at most 64. If both
still fit, the layout whose declared lengths match the decoded text wins. Vendor stays the
default when both readings are equally plausible, and unambiguous lengths are unchanged.
Refs #740
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
H17: the .n read-modify-write hard-coded a DINT parent. On an INT or SINT host
(both legal in Logix, and reads of Flags.3 there already worked) the DINT
decode of a 2-byte buffer threw OutOfBounds, the generic catch evicted the BIT
tag's (non-existent) runtime and reported BadCommunicationError + Degraded.
The parent width now comes from the parent read's size (1 SINT / 2 INT /
4 DINT / 8 LINT; unknown keeps the DINT assumption). Narrow hosts use unsigned
arithmetic so a set top bit encodes without overflow; a bit past the host's
width is BadOutOfRange and a non-integer width BadTypeMismatch, both refused
before anything is written, warned once, no health write. A transport failure
in the RMW now evicts the parent runtime it actually used. Native end-to-end:
an INT host is written as ONE INT (type 0xC3, 2 bytes).
Refs #737
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The handle-recycle loop disposed the device client with no gate. It could null a client a
concurrent EnsureConnectedAsync had just installed (orphaning a live two-socket session),
or dispose one a poll was mid-read on (ObjectDisposedException -> BadCommunicationError +
Degraded on every recycle interval).
The recycle now takes the device's ConnectGate, detaches the client, and disposes it via
SynchronizedFocasClient.DisposeWhenIdleAsync, which waits (bounded by the call timeout plus
slack) for ops that already hold the client. The gate stays held through the drain, so no
fresh session opens beside the old one.
SynchronizedFocasClient no longer disposes its call gate. Releasing a disposed semaphore
threw out of reads that had otherwise completed. Ops that reach a disposed client now get
ObjectDisposedException and are never run on the dead socket.
Refs #740
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Review 07 H16: an array of String/Timer/Counter/Control passed the mapper, so
every poll created a handle (one init read), the decode threw
NotSupportedException, the generic catch evicted the handle and latched
Degraded. FromTagConfig now rejects that combination (the skip carries the
reason, Inspect/deploy gate and the AdminUI model state it), and a runtime
NotSupportedException on read or write is BadNotSupported: handle kept, no
health write, one Warning per tag and operation. Write refusals (native PLC-5
and status-bit writes, libplctag translated addresses) now warn once per tag too.
Refs #738
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
P8: on the native transport the bounded-parallel read window is also the cap
on services per Multiple Service Packet (the device's shared scheduler packs
whatever is queued, within the connection's request/reply byte budget), so the
default 8 cost a 1000-tag controller ~125 round trips per poll instead of ~10.
The effective window (AbCipDriver.ReadWindow) is now max(64, option) when the
native tag factory serves reads; libplctag and injected factories keep the
option exactly. Option doc + AdminUI help text updated (Razor: Wave 4 live
check).
P7 addendum: a work item now takes its window slot only after its runtime
exists. A cold create queues on its device's single-flight connect gate, and
holding a slot there let one dead device's backoff-expiry attempt occupy the
whole window for a full Timeout, stalling every other device's reads.
Refs #737
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
ReadAsync walked the whole batch sequentially, so one SLOW CNC (TCP-accept-then-stall,
the live 31i-B case) cost Timeout per tag per poll while no other device was read.
ReadAsync now resolves every reference against one table snapshot, buckets the rest by
device and reads the devices with Task.WhenAll; each device's tags still go in order on
its own serialised socket (the PMC coalescing pre-pass runs per device, first). Results
land at their own indices.
Also precomputes each device's fixed-tree key prefix (it was built per reference, twice
per poll).
Refs #740
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Review 07 L7: each index value an indirect tag (N7:[N7:0]) swept through left a
per-runtime and a creation SemaphoreSlim in the device's gate tables until
shutdown. A moved index now drops the stale resolution's gates along with its
handle, and sweeps any other stale resolution of the same tag a concurrent
reader cached, so the tables stay bounded by the authored set.
Refs #738
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Found by the H13 stress test (200 re-inits under a concurrent reader): a read
that resolved the device just before the table swap could cold-create a
runtime into the retired state after its teardown had disposed it (leaked
native handle / lease), and could hit a per-tag SemaphoreSlim the teardown had
disposed, which the generic catch reported as a comms fault (Degraded).
- DeviceState.Retire marks the state retired before disposing handles; each
handle is removed-then-disposed exactly once. A creator re-checks the flag
after its TryAdd (fenced, Dekker-paired with Retire) and disposes the orphan.
- A failure on a retired device is the teardown's doing: BadCommunicationError
for that one call, no evict, no health signal.
- Per-tag/RMW gates are no longer disposed (async-only waits hold no handle),
matching the ConnectGate rationale.
Refs #737
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
H10: the probe loop recorded EVERY exception - including the controller
answering NotFound for a typo'd or download-deleted Probe.ProbeTagPath - as a
Forward-Open failure. At a 5 s tick against a 30 s backoff cap ShouldAttempt
was never true again, so every cold or evicted data tag on a reachable device
read BadCommunicationError indefinitely and the host showed Stopped.
The probe now decides the backoff verdict and the host state separately:
- a device refusal (thrown or as a status word) is backoff success + host
Running + one Warning per device naming the probe tag; an initialised probe
runtime is kept so its lease is not re-opened every tick;
- a malformed probe tag name (AbCipTagConfigurationException) never reached
the device: no backoff signal, no host transition, one Warning;
- a genuine transport failure is unchanged (backoff failure, host Stopped).
Refs #737
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
FocasDataType.String was authorable on any address, but no area read returns text: PMC
fell through to a byte read, PARAM to Int32, MACRO to a double, and the String node
received a boxed number at Good.
One rule, FocasTagDefinitionFactory.DescribeDataTypeMismatch, now backs every path:
- FromTagConfig rejects the pair, so the driver skips + reports it (BadNodeIdUnknown,
never a Good number) and Inspect names the reason at deploy;
- FocasTagConfigModel.Validate refuses it on the typed fields;
- the AdminUI editor only offers String where it is readable and shows the rule's text
inline (kept visible for a loaded blob that already carries it);
- the CLI read/subscribe/probe/write commands refuse it at the boundary.
String stays valid on FIXED: paths (Identity/Program name/mode text) and is ignored on
ALARM: tags; an unparseable address keeps its own diagnosis.
Razor change (FocasTagConfigEditor.razor) needs the Wave 4 live check.
Refs #740
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Array tags were advertised writable but every write threw InvalidCastException
in ConvertForWrite (reported BadTypeMismatch); STRING writes went through the
Beckhoff marshaller with no length check against STRING(n) and the host's
ANSI code page, which the read side deliberately avoids.
- Array write: TwinCATArrayCodec.ToWriteElements converts exactly ArrayLength
elements to the declared type (CLR lists convert - ScadaBridge writes int[]
to Int16 nodes; a length mismatch or out-of-range element is BadOutOfRange, a
scalar value BadTypeMismatch) before any wire traffic; the ADS client plans
the layout from the resolved PLC array (TwinCATTypeGuard.CheckArray, as the
read does), encodes with TwinCATArrayCodec.Encode - the exact inverse of
Decode - and writes the raw bytes (new ITwinCATClient.WriteArrayAsync).
- STRING / WSTRING write: encoded at the PLC's declared width by
TwinCATStringCodec.EncodeString/EncodeWString (Windows-1252 or UTF-8 per
target, NUL-padded, strict: an over-long value or unrepresentable character
is OverflowException -> BadOutOfRange) and written as raw bytes.
- TwinCAT CLI read/write gain --array-length (+ --separator) for the hardware
gate.
Refs #739
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The fixed-tree loop swallowed every failure at Debug and never touched health, so a
driver serving only FIXED: tags (Identity/Axes/Program/Status, the typical FOCAS shape)
read Healthy on /hosts with every node Bad and the #527 watchdog could never fire.
The fixed tree is now a third health path beside the value and alarm paths, combined in
GetHealth (worst state, latest LastSuccessfulRead):
- an answered bootstrap / axis pass clears the device's failure and advances
LastSuccessfulRead;
- a transport failure degrades the driver once the device has been silent past the
same staleness budget that turns its values Bad (from its last answer, or from loop
start when it never answered), with LastSuccessfulRead frozen;
- a CNC refusal (non-OK rc) is not a comms loss: it clears the failure and credits nothing.
Refs #740
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The bit write read and wrote the parent word as a 32-bit UDInt with no parent
check: a bit beyond a 16-bit parent was written into neighbouring bytes, and a
signed parent with its sign bit set read back >= 2^31, so the checked
conversion turned any bit write into BadOutOfRange.
The write now goes through ITwinCATClient.WriteBitAsync: the ADS client
resolves the parent symbol, checks the bit against it (TwinCATBitAccess.
CheckParent, as the notification path already did), reads exactly
parent.ByteSize raw bytes, flips one bit (TwinCATBitAccess.ApplyBitWrite) and
writes the bytes back by index group/offset or variable handle. A bit beyond
the parent is BadOutOfRange, a non-integer parent BadTypeMismatch, a short
parent read BadCommunicationError (never written back), all without a health
write. The per-parent RMW lock stays in the driver.
Refs #739
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Re-review 1: HandleDispatch's terminal guard and its AwaitingApplyAcks flip read the row separately, so a
lost-dispatch closure committed between them was silently reopened. The flip now carries the RowVersion the
guard read; a change in between is a concurrency conflict (nothing seeded, nothing published, coordinator
reset). Pinned on real SQL Server with a closure injected between the two reads (fails without the fix).
AdminOps' apply deadline and the coordinator's now both read DeployTimings.ApplyDeadline, passed explicitly
to both singletons. Microsoft.IdentityModel.Protocols(.OpenIdConnect) pinned to 8.11.0 and referenced
directly by the Security project, so the whole IdentityModel family resolves 8.11.0 (fresh restore clean
of NU190x/NU1605).
Refs #733
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
H1/L4: one classification (AbCipRefusals.IsDeviceRefusal) of the statuses
that prove the controller answered - NotFound, OutOfBounds, NotAllowed,
TooLarge, TooSmall, TypeMismatch, Unsupported - shared by the data path, the
Test-Connect probe (IsReachableStatus widened) and the native runtime.
- A refused read/write (thrown or as a status word) is per-tag Bad with a
once-per-tag Warning, keeps the runtime (no evict, so no lease/Forward-Open
churn for a sole lease holder), writes no Degraded and, since the device
answered, advances LastSuccessfulRead without touching the state.
- A refused cold create records the backoff as reachable, so siblings are no
longer throttled for up to 30 s by one Arr[999].
- The native runtime completes InitializeAsync on any refusal (it used to on
TypeMismatch/Unsupported only) and reports it on every later read.
- A refused READ of NotAllowed reads BadNotReadable, not BadNotWritable.
- Test Connect names the refusal ("probe tag refused: OutOfBounds").
0x1C/0x20/0xFF-0x2104 still fold into BadReply inside Driver.Ab.Transport
(Lane K follow-up); they remain comms faults until mapped there.
Refs #737
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The capability matrix admits #0..99999 on 30i/31i/32i (and anything on Unknown), and
the FOCAS/2 request block has always carried 32-bit arguments, but WireFocasClient cast
every number to short: MACRO:99999 asked the CNC for #-31073 and published that variable
at Good under the authored tag. FocasWireClient's macro/parameter reads, WireMacro.Number
and WireParameter.DataNumber are now int; the request blocks come from MacroRequest /
ParameterRequest builders (byte-identical to the live 31i-B capture for #500).
Same class on PMC: a range whose last byte passes 65535 (Unknown series admits it) is now
refused BadOutOfRange instead of wrapping onto a different 16-bit address.
The wire client is in-process (the other end is the CNC itself), so this is not a
cross-repo contract change. Whether a real 30i honours cnc_rdmacro Arg1 > 32767 is the
hardware userGate.
Refs #740
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
CompleteRead logged a Warning for every non-Good status on every poll and
latched Degraded for all of them. Now a bad tag warns once per bad episode
(re-armed when it reads Good, and on re-initialise), a comms-class status
(BadCommunicationError / BadTimeout) degrades with LastSuccessfulRead
preserved, and any other status - the device answered and refused this tag -
advances LastSuccessfulRead with no state change. Read-path exception
handlers now go through MarkCommsFault, so they never downgrade Faulted.
Refs #739
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Review 07 H13: _devices and _tagsByRawPath were plain dictionaries cleared and
refilled in place while the retained poll loop, the actor's GetHostStatuses and
server reads enumerated them. Both are now built locally and published by
reference under a lifecycle lock; teardown swaps in empty tables.
Lane A contract: ShutdownAsync and Dispose each retire a disjoint set of device
states, so Dispose running concurrently with a still-joining ShutdownAsync is
safe. A lifecycle epoch makes an InitializeAsync that the runtime abandoned
(overlapping the next ShutdownAsync) refuse to publish its tables, start probe
loops or write health. A runtime cached on an already-retired device state by an
in-flight read is disposed instead of leaked, and late reads/writes no longer
overwrite shutdown's health. Per-key semaphores are no longer disposed under
callers that may still hold them.
Refs #738
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
In native-notification mode LastSuccessfulRead never moved past the init
stamp, so one Degraded write on a connection older than 90 s latched the
comms-loss watchdog into a full reconnect (every notification on every device
deleted and re-registered). Conversely an unreachable AMS router was swallowed
by the probe and never left Healthy.
- a native push and a successful probe now stamp LastSuccessfulRead (throttled
to one health record per 250 ms) and restore Healthy unless a device is still
probe-unreachable;
- 3 consecutive failed probe ticks write Degraded with the stamp preserved;
- a NotSupportedException write is BadNotSupported with no health write (#611);
- a reconnect replay the PLC refuses republishes the refusal's status without
degrading (it used to report BadCommunicationError + Degraded on every
reconnect for a correctly-isolated type-mismatch tag).
Refs #739
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
_devices was a plain Dictionary cleared and refilled in place by InitializeAsync /
ShutdownAsync while the retained poll engine, the fixed-tree and alarm loops and the
actor's health tick enumerated it ("Collection was modified"). It is now built whole and
published by reference swap, and a release swaps it out to empty before tearing it down.
Lane A's runtime overlaps lifecycle calls, so the driver now tolerates both shapes:
- a lifecycle generation is bumped by every Initialize/Shutdown; an initialise that finds
itself superseded (abandoned by the runtime, then a shutdown ran) publishes nothing,
starts no loops, writes no health and throws OperationCanceledException;
- a shutdown overlapping another (dispose beside a still-running shutdown) waits for the
first's teardown via a release tail instead of returning on an empty table;
- released devices are Retired: EnsureConnectedAsync refuses to reconnect them, and a
connect that completes after retirement disposes what it opened. Clients are disposed
under the device ConnectGate (bounded).
Refs #740
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
H13: _devices/_devicesByRoutingKey are published by reference swap under a
lifecycle lock and never mutated after publish, so the retained poll engine,
discovery and the actor's GetHostStatuses pull never read a table mid-Clear.
Every retire (init's own release, shutdown, dispose) takes the table it
replaces, so ShutdownAsync racing DisposeAsync tears each state down once, and
a generation check makes an InitializeAsync overtaken by a shutdown publish
nothing (it throws OperationCanceledException) instead of resurrecting probe
loops behind the shutdown. Probe join is one bounded 5 s wait independent of
the caller token.
H21: _health is volatile and read-modify-write updates go through a CAS.
F10: the sync Dispose() (sync-over-async) is removed; DisposeAsync is the
complete, idempotent teardown the runtime calls after ShutdownAsync.
Refs #737
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Native subscribe was all-or-nothing: any registration failure other than a
type refusal disposed every registration and rethrew, so one typo'd symbol or
one unreachable PLC in a multi-device driver served zero data, churned
register/delete every reconcile tick, and left health Healthy.
Now each registration fails on its own: a refusal (the device answered: symbol
not found, PLC not ready, type mismatch) publishes its status with no health
write; any other per-tag failure publishes BadCommunicationError and degrades;
a connect failure marks the device unreachable for the rest of the call and
stores its tags as dead intents. Every failed tag is kept as a dead intent that
the probe-tick retry and the reconnect replay re-register. The ADS client now
classifies a failed symbol resolve / AddDeviceNotification by status instead of
throwing InvalidOperationException for all of them. Cancellation still tears
the partial subscription down.
Refs #739
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Ruling refinement on I1. Only timeouts are strikes, so a never-returning
while(true), which times out once and is then only refused, was never
quarantined, and that defeated E1. A refusal now quarantines immediately
when the orphan it was refused behind has been executing for longer than
ScriptingOptions.StuckOrphanQuarantineFactor x the script's timeout
(default 10, so 20 s at the 2 s default; 0 or less disables it). It uses
the same quarantine path: one Error, otopcua.script.quarantined with
reason=stuck, Bad, lifted on source change or redeploy. A young orphan
(a short overrun) is still a plain refusal.
The guard stamps the run's start (Stopwatch timestamp) when the pool
picks it up and clears it when the run really finishes.
Tests: the 30-trigger while(true) regression (paced) now ends
quarantined with reason "stuck", still with exactly one orphan and a
healthy sibling. Positive control: a 2x overrun is refused, not
quarantined, and evaluates again once the orphan completes. A factor of
0 disables the rule. Docs (ScriptEditor "Runtime safety", VirtualTags)
and the seam remarks are updated.
Refs #734
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The native subscribe path silently skipped a reference it could not resolve
(unknown RawPath, or a tag routed to an unconfigured device), leaving the node
on whatever status the server seeded. It now publishes one BadNodeIdUnknown
snapshot, matching the poll path.
Refs #739
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
BoundedApiKeyStore kept the set (volatile) and its DateTimeOffset stamp (non-volatile, 16 bytes) in separate
fields, so a reader could pair a new set with an old stamp or read a torn stamp; they are now one immutable
snapshot behind a volatile reference. An inner store that cannot list ids now switches the set off with a
per-instance flag instead of writing KnownIdSet = false into the shared ApiKeyStoreGuardOptions.
Refs #733
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
RefreshAsync now tells "the store answered: no such secret" (revocation - drop the refreshed key AND the
lazily cached one) apart from "the read failed" (keep the previous key). Store reads fan out through
Parallel.ForEachAsync capped at MaxConcurrentRefreshReads = 8 instead of one read per cluster at once.
Refs #733
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The one-snapshot refactor re-sorted every collection in memory with an ordinal comparer, while the old
composer's SQL ORDER BY used the database's case-insensitive collation; mixed-case keys therefore re-hashed
an unchanged configuration (spurious drift fleet-wide, a "new" revision on a no-op redeploy). The snapshot
factory now reads every composed table ORDER BY its natural key server-side and Compose serialises in the
order given. Pinned byte-for-byte against a verbatim replica of the old composer on the real SQL Server.
Refs #733
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Review fix round 2 for lane F:
- N1: the init platform seed no longer runs inline under the init token. Galaxy's Tier-A
Initialize budget is 5 s, and a cold gateway DiscoverHierarchy can spend all of it, so the
OperationCanceledException rethrow failed init, opened the Initialize breaker and cost a full
rebuild per retry. InitializeAsync now only resolves the platform source (no network) and
queues a background seed tied to a per-runtime CTS that the teardown cancels. A result that
lands after its runtime was torn down is discarded.
- N2: the seed worker serves the runtime that is live when each pass STARTS, so a request made
under a new runtime while a stale pass is in flight always gets a pass of its own.
- N3: SubscribeAsync and the subscribe-once read capture the runtime generation before
SubscribeBulk and register only if it is unchanged, atomically with the teardown's registry
Clear (_registryGate). On a mismatch they release the handles and fail the call. Re-subscribe
Rebind uses the same gate, and the production rebuild clears the registry unconditionally.
- PerPlatformProbeWatcher re-checks its stop after the SubscribeBulk await, atomically with
the record and publish. A pass that straddles StopAsync releases the handles it acquired
instead of writing the probe entry back into a cleared registry.
Refs #735
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
I7: a Dispatching row committed after the coordinator's PreStart whose Tell never arrived had no owner and
refused every later deploy. The in-flight check (now fully off the admin singleton's thread, serialised by the
actor-local compose flag alone) closes a Dispatching row with zero NodeDeploymentState rows that is past the
apply deadline as TimedOut (optimistic on RowVersion) and proceeds.
HandleDispatch ignores a dispatch for a Sealed/PartiallyFailed/TimedOut row, so a late or duplicated dispatch
cannot flip it back. Coordinator status/reason writes attach a key+RowVersion stub instead of loading the
multi-MB ArtifactBlob; proven on the real SQL Server (blob untouched, seal lands).
Refs #733
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
SQL Server's DbUpdateException for one duplicate names every entry in the statement batch, so detaching
ex.Entries dropped the whole flush. On a row-level rejection the writer now asks the database which of the
batch's EventIds it already holds, drops exactly those, re-saves the rest, and falls back to row-by-row only
if a non-duplicate row is still refused. Fresh context + entities per attempt. Pinned against the real
central SQL Server (new SqlServerTestDatabase harness) and a faithful whole-batch interceptor.
Refs #733
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT