Live gate A1 (docker-dev, opc-plc restart / SIGINT / kill): the fast path never fired —
a real process stop delivers no session status; the keep-alives report
BadSecureChannelClosed (0x80860000) once, then BadConnectionClosed (0x80AE0000)
interleaved with BadNoCommunication for the whole outage.
Reproduced in-process with TcpStallProxy.HardClose (reset every connection, refuse new
ones; server and session alive behind it): the identical sequence, and the SDK 1.5.378
session never opens a new connection on its own (48 s with the proxy accepting again,
zero attempts) — a closed channel cannot recover in place.
The driver now treats BadSecureChannelClosed/BadConnectionClosed as definitive on the
SECOND closed-channel keep-alive failure in one outage (a good keep-alive resets the
count), raising ConnectionLost ~1 keep-alive after the drop. BadNoCommunication /
BadRequestTimeout / BadNotConnected (stall/pause) stay with the watchdog; the stall test
still sees no ConnectionLost. New wire test (hard close + reopen ⇒ raised once, SDK never
reconnects, reinit brings the identical value back Good) and unit tests (sustained raises
once; a single blip that recovers does not) — all red on the previous code. Docs updated.
1. A per-ref delivery counter (bumped under the delivery lock by every publish path) is
captured before the trailing read is issued; a ref delivered to since is skipped.
Without source timestamps the read's sample could not be ordered against a notification
that landed mid-read, and publishing it regressed the node. Test injects the
notification inside the mocked read, with and without a read source time (red before).
2. Delivery-lock comment corrected (it serialises across subscriptions, which the SDK
dispatches on separate workers); PublishCommsLoss now publishes under the lock too.
3. CancelSessionWork cancels without disposing, so a keep-alive thread reading the old
token cannot hit ObjectDisposedException.
1. RewriteEndpointUrl keeps the advertised port when the configured URL names none
(Uri.Port -1 would have sent the session to 4840); port-less + IPv6 tests.
2. The trailing re-read repairs any (value, status) difference that is not older than
the last delivered value — Good->Bad/Uncertain included; a read without a source
timestamp counts as newer; an equal source time with different content is published
(repairs the replay guard's by-design equal-timestamp drop).
3. One driver-wide delivery lock makes decide+publish atomic across live notifications,
the recovery read and the trailing read, so an older value can never land after a
newer one (deterministic race test via a seam).
4. Known gap documented: a ConnectionLost raised while the host is not Connected is
swallowed and that session falls back to the watchdog.
5. Only a SERVER-reported subscription loss raises ConnectionLost; the publishing-stall
heuristic stays with the #527 watchdog.
6. Post-recovery timers run on Task.Delay(…, Clock, ct) with a session-work CTS
cancelled on session release and dispose.
7. Replay summary at Information only when something was dropped (Debug otherwise);
a re-arm reports the superseded window's drops and counts afresh.
8. DriverInstanceActor: AttachHostStatusSource doc comment restored; Reconnecting
swallows a stray DisconnectObserved (test).
9. Stall wire test: 120 s session timeout, 3000-cycle subscription lifetime, one further
bad keep-alive tick, 60 s headroom on the post-recovery waits (5/5 green).
- Endpoint rewrite: the driver now connects to the configured host AND port (scheme
match, advertised path kept) instead of the server-advertised URL — fixes NAT/port-map
upstreams and lets an in-test proxy carry the session (SDK SelectEndpoint rule).
- TcpStallProxy + OpcUaClientDriverStallWireTests: the in-place blip (#670) is now
wire-tested on loopback — one Bad, frozen read stamp, same session, identical value
republished Good, a post-recovery change arrives, no source-time regression after
the SDK's late backlog flush.
- Defect found by that test, fixed: a change published right after a stall rode a
Publish response the SDK timed out and never republished, leaving the node Good on
the pre-change value indefinitely. New trailing reconcile read (Timeout +
KeepAliveInterval after recovery) publishes any Good value newer than the last
accepted one, through the replay guard's mark.
- IDriverConnectionLossSource (Core.Abstractions): opt-in definitive-loss signal.
DriverInstanceActor attaches in PreStart / detaches in PostStop and turns a raise
into a disconnect only while Connected. OpcUaClient raises once per session on
keep-alive BadSessionIdInvalid/BadSessionClosed/BadSessionNotActivated/
BadServerHalted (measured: the SDK never re-opens a halted channel) or a dropped
subscription; ambiguous codes stay with the #527 watchdog.
- Replay guard: one Information summary per recovery when the window closes
("dropped N late notifications across M refs"), with a timer so quiet
subscriptions log it too.
- ReconnectPeriod deleted (options, AdminUI form, docs, tests); stored configs that
carry reconnectPeriod still parse in the factory, probe and browser.
- Docs: OpcUaClient.md, DriverLifecycle.md, driver-specs.md, CLAUDE.md.
The F2 live gate failed (10 value regressions over 4 blips): IsLateReplay
disarmed a ref on its first in-order notification, which arrives ~1 s after
recovery, while the SDK's late replay lands 4-6 s later. Equal source times
also passed, so a replay equal to the recovery read got through.
While the window is open each ref now carries a high-water mark (seeded at
arming, raised by the recovery read, advanced by every accepted notification);
a notification at or below it is dropped (equal included — OPC UA moves the
source timestamp on every value/status change). Null source time passes
without moving the mark. Window expiry still disarms entirely, so an upstream
clock step-back is never frozen outside the window. Arm/expiry serialised by a
lock so an expiry racing a re-arm cannot wipe fresh seeds.
The global 'never older than the last Good source time' rule froze a node
whenever an upstream clock stepped backwards (NTP correction, PLC clock
reset) until the clock caught up. The check is now a replay guard armed
only by a same-session recovery (keep-alive bad->good): per ref it holds
the last Good upstream source time (raised by the recovery read), a ref
disarms on its first in-order notification, and the whole guard expires
after max(30 s, 2x the longest subscription keep-alive window). Outside
it every notification is accepted. The steady-state tracker records the
LAST accepted time, not a high-water mark.
F1: the driver's outage BadNoCommunication carried the last Good sample's
source timestamp. The recorder historizes SourceTimestampUtc ??
ServerTimestampUtc, so the Bad landed on the Good row's (TagId,
SourceTimeUtc) key and the insert-if-absent historian dropped it - no
outage marker until the host's watchdog marker ~95 s in, none at all for
a short blip. Now stamped with the detection time (source + server), as
the host's comms-loss fan does.
F2: after a same-session recovery the SDK delivered a missed notification
seconds late with an older source time and the node regressed. A
notification older than the newest Good upstream source time for its ref
(notification or recovery read) is dropped and counted
(stale_notification_dropped); equal timestamps pass; the outage Bad never
moves the comparison; a re-initialise resets it.
M1: a subscription that dies while the session lives (outage longer than
the subscription lifetime but shorter than the session timeout) used to
end Healthy with fresh keep-alive stamps and frozen values. PublishError
BadNoSubscription / BadSubscriptionIdInvalid naming a tracked
subscription, or a tracked subscription whose SDK PublishingStopped
persists one more keep-alive window + 5 s across good keep-alives, now
declares it lost: Degraded, outage published once, and nothing advances
LastSuccessfulRead until the session is released, so the #527 watchdog
re-initialises and re-subscribes. Both detectors wire-tested.
M2: in-place recovery is bound to the session whose keep-alive recovered;
one overtaken by a re-initialise no longer re-arms the new session's
outage latch or degrades its health (ReadCoreAsync expectedSession).
L1 CAS health updates; L2 re-check before each recovery publish; L3 skip
CloseSession on a lost session; L4 SDK log forwarding rate-limited
(20/min); L5 per-driver SDK LoggerFactory disposed with the driver.
Wire test asserts the read stamp stays frozen while the server is down.
A bad keep-alive now degrades health (LastSuccessfulRead preserved) and,
once per outage, publishes BadNoCommunication (value retained) for every
subscribed ref plus a quality-only annotation on subscribed alarm
conditions. Good keep-alives and data/event notifications advance
LastSuccessfulRead, so an idle-but-alive subscription never looks dead
to the #527 watchdog. A keep-alive that recovers on the same session
re-reads the Bad refs and republishes them Good; a session that does not
come back is recovered by the watchdog's ShutdownAsync + InitializeAsync
+ re-subscribe.
Deletes the SessionReconnectHandler wiring (it retried forever in SDK
1.5.378, cloned subscriptions the driver never re-tracked and kept health
Healthy), OnReconnectComplete, TryRearmReconnect and the reconnect_*
counters (new keepalive_recovered). Teardown of a lost session skips
wire deletes and bounds CloseSession. SDK warnings reach the driver log.
Wire test reworked: restart => Bad, then watchdog-style reinit => Good.
After an OpcUaClient respawn an upstream inactive+unacked condition went out as
Retrigger+Clear (duplicate Activated+Cleared rows, Active flicker), and a
first-sight inactive+acked one as Unspecified (an Activated row for an inactive
alarm; a retained-Active host condition never cleared).
- New AlarmTransitionKind.InactiveUnacknowledged: one projection, rows only for
what changed (Activated+Cleared from acked, Cleared from active+unacked, none
when already inactive+unacked).
- OpcUaClient uses it for moves into inactive+unacked; first sight of an
inactive condition is InactiveUnacknowledged or Clear+Acknowledge, flagged.
- Projector: a flagged Acknowledge on an already-acked condition writes no row.
- E2E tests through DriverHostActor.ForwardNativeAlarm (red-proven).
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
- AlarmTransitionKind.ActiveAcknowledged (appended): active AND acked applied as ONE projection.
Galaxy ActiveAcked snapshot entries and OpcUaClient inactive->(active,acked) use it; the
projector writes 'Activated' only if not already active, 'Acknowledged' only if not acked.
- AlarmEventArgs.IsRestatement (optional, default false): set only by Galaxy snapshot entries
and OpcUaClient first sight. A flagged Retrigger on an Active+unacked condition with the same
message and severity, or a flagged Clear on an inactive condition, writes no /alerts row.
- NativeAlarmProjector reports the history rows per transition; ForwardNativeAlarm writes one
row per entry. Unflagged sources (FOCAS/MTConnect/AbCip, live Galaxy) are unchanged.
- Tests: projector rules each with a must-write control; OpcUaClient transition table;
Galaxy feed/driver mapping; Galaxy + OpcUaClient end-to-end through DriverHostActor.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
HistoryRead is served server-side by IHistorianDataSource; nothing ever dispatched
to a driver's IHistoryProvider. Removes IHistoryProvider, the OpcUaClient history
passthrough, DriverCapability.HistoryRead (+ resilience tier rows and AdminUI row),
HistoryReadStatusException and its node-manager catches, and the tests that only
covered them. Shared result types and HistoryAggregateNotSupportedException stay
(moved to Historian/HistoryReadContracts.cs). A stored ResilienceConfig still
carrying a HistoryRead key parses (diagnostic only; new test).
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
MAJOR-1: a deploy that changes a driver's config respawns it, and the fresh instance's empty told
record re-sent Raise for every still-active alarm, un-acking acknowledged conditions and writing a
duplicate "Activated" alerts row. NativeAlarmProjector now treats Raise on an already-active
condition as a re-statement (keeps Acked; ForwardNativeAlarm skips the alerts row); only Retrigger
(or inactive->active) un-acks. Sources whose upstream ack state is authoritative send Retrigger for
an unacked re-statement: OpcUaClient on first sight (no prior told), Galaxy for an unacked active
snapshot entry. Runtime E2E drives a FRESH FOCAS driver after a redeploy and asserts the ack survives.
MAJOR-2: a failed FOCAS alarm read annotates each subscribed condition BadNoCommunication once per
outage (#626 quality-only path) with one Warning (MINOR-6), lifted to Good on recovery; failed alarm
reads degrade driver health with LastSuccessfulRead frozen (successful ones advance it), so an
alarm-only driver trips the #527 comms-loss watchdog.
MINOR-3 CLAUDE.md #630 bullet; MINOR-4 split line; MINOR-5 a non-empty cnc_rdalmmsg2 payload that
fits neither stride throws; MINOR-7 value-tag + parsed-address tables are built and swapped, never
cleared in place under the retained poll engine. Docs corrected (FOCAS.md, AlarmTracking.md, CLAUDE.md).
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
Nothing read the mapping table beyond the startup validator; v3 UNS projection is
explicit via UnsTagReference. Legacy keys in stored DriverConfig are ignored (pinned).
Reverts the docker-dev opc-plc seed workaround from fdee129f.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
Re-review of 3de2cc3b/454775c6:
- AlarmTransitions could not reach (inactive, unacked): (active,acked)->(inactive,unacked) emitted Clear
(host stayed acked) and a first-seen cleared-unacked condition emitted nothing. The table is now total;
an exhaustive test replays every (prior, target) pair through the projector's semantics.
- The per-RawPath read-compute-emit was a lock-free TryGetValue/set across SDK publish threads; it now runs
under one lock with the projection and emission.
- Condition BRANCH events (non-null BranchId) were projected (flipping the trunk) and remembered as the ack
target (acking the branch); they are dropped. BranchId is select clause 9.
- EventId is copied, not aliased from the decoded notification.
- An unchanged state re-emitted Unspecified; it now emits nothing unless message/severity changed (an
Unspecified projects from the host projector's default after a redeploy reset it).
- Exact upstream severity rides OpcUaSeverity (#626) instead of being re-bucketed.
- ShutdownAsync no longer forgets the last-told state: a reinit re-subscribes the same set and the refresh
would otherwise re-raise every acked alarm. A CHANGED set (host rebuilt) forgets it.
ConditionRefresh: called after the alarm event item is created, after an in-place reconnect (subscriptions
found on the new session by display name, since a recreate clones them) and on RefreshRequired. Refresh
markers are never projected. BadNotSupported/BadMethodInvalid/... logs once. Wire test: a condition already
active before subscribe is reported Raise; a release+resubscribe refresh re-raises nothing (falsified by
disabling the refresh call).
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
NativeAlarmProjector derives Active/Acked ONLY from AlarmEventArgs.Kind, and this driver
never set it - every routed event projected Unspecified, leaving the condition inactive+acked
(only Message/Severity moved). The live-gate expectation 'toggling Active as opc-plc cycles'
could not have passed. Select ActiveState/Id + AckedState/Id (two-element browse paths) and
emit the Kind sequence that moves the projector from the state last told to the host to the
event's (Raise+Acknowledge when a notification carries both).
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
The alarm index was keyed on ns=N strings resolved once at subscribe time, while an
in-place SDK reconnect transfers the subscription without re-running it - a remote
namespace reorder silently orphaned every alarm tag. Keys are now nsu= on both sides.
Events match the authored nodeId against the event's ConditionId first, then its
SourceNode, so several conditions on one source can be authored 1:1. Acknowledge
passes the EventId of the event that named the remembered condition (paired, so node
and EventId can never come from different conditions) instead of an empty one.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
The host subscribes alarms with RawPaths and routes transitions on
(driver, RawPath), but the driver filtered upstream SourceNode ids against
the RawPaths and reported the upstream condition NodeId as ConditionId, so
no opc-plc (or any upstream) alarm could ever reach a condition node.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
FOCAS, AbLegacy, AbCip, TwinCAT, S7 and OpcUaClient orphaned the previous
probe/recycle/fixed-tree loops and clients when re-initialised on a live driver.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
G-7 wired OpcUaClientTagDefinitionFactory.Inspect into the deploy-time TagConfig
gate, which gave ControlPlane a ProjectReference to
Driver.OpcUaClient.Contracts — and with it, transitively, the whole OPC UA client
stack (5 OPCFoundation packages) into every host that loads the control plane.
NamespaceMap was the only reason Contracts carried
OPCFoundation.NetStandard.Opc.Ua.Client: its entire public surface is
ISession/NamespaceTable/NodeId-typed. It moves to a new leaf project,
ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient.Session, referenced by the runtime .Driver
and by .Browser. Contracts is left with Core.Abstractions and NOTHING else —
the same shape as Calculation.Contracts.
The namespace stays ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient, so no consumer's
`using` changed. The .Session -> .Contracts direction is deliberate: the blob
read NamespaceMap needs is OpcUaClientTagDefinitionFactory.TryReadNodeId, the
one authority it shares with the deploy gate, and that must stay in the
dependency-light half.
Why a new project rather than folding NamespaceMap into the runtime .Driver and
having .Browser reference it (the Driver.Mqtt.Browser #512-style deliberate
exception): the AdminUI project-references .Browser and NOT .Driver, so that
shape would pull the OpcUaClient driver runtime — plus Core,
Opc.Ua.Configuration and Secrets.Abstractions — into the AdminUI's build/deploy
graph. That is exactly the violation #512 spent two extractions removing from
Mqtt.Browser; re-introducing it to save one csproj is a bad trade.
Guard: ContractsIsDependencyLightTests (Driver.OpcUaClient.Tests) asserts the
Contracts manifest names no Opc.Ua* assembly, plus a counterpart asserting
.Session does. An ABSENCE assertion is sound on the manifest where a presence
one is not — the compiler elides an unused reference, but it MUST emit one the
moment Opc.Ua-typed code is added. Falsified by temporarily re-adding the
package plus an Opc.Ua.NodeId-typed member: red on Opc.Ua.Types, green again on
removal.
Evidence — `dotnet list ControlPlane package --include-transitive | grep -i opc`:
before: OPCFoundation.NetStandard.Opc.Ua.{Client,Configuration,Core,
Security.Certificates,Types} 1.5.378.106
after: none (and 0 Opc.Ua*.dll in ControlPlane's output directory)
Both `IDriver` members had no production call site. Their only consumer was
`MemoryTracking`, deleted with the driver-tier recycle machinery in #522, and
`GetMemoryFootprint`'s doc-comment claimed "polled every 30s by Core" — which
had not been true since v3, even before #522 removed the poller.
Owner decision on #525 was (a) delete rather than (b) build the process-wide
watchdog that would consume them. The driver-side implementations are in git
history and were mostly reusable; what was always missing is the trigger, and a
member nobody calls is how the misleading doc-comment survived this long.
Removed from `IDriver`, all 12 driver implementations, and every test stub —
plus the support code that existed only to feed them, which is the part a
member-only deletion would have left behind as dead weight:
- MTConnect's three per-entry byte-weight constants, its cached
`ProbeModelDataItemCount`, and `CountDataItems` — a full device-tree walk run
on every cache fill to populate a number with no remaining reader.
- OpcUaClient's `_discoveredNodeCount` field and the discovery-pass write to it.
- MQTT's `ApproxBytesPerAuthoredTag`.
Two behavioural notes, neither a change in what the software does:
- `AbCipTemplateCache` now has no production reset path. Its only caller was
AB CIP's flush, which itself had no caller — so nothing changes except how
visible the fact is. Recorded on the type, along with the correction that its
comment's claim about a device `ReinitializeAsync` also flushing it was never
true. A UDT redefined on a live controller keeps its stale shape until the
driver instance is rebuilt.
- MTConnect's `/probe` cache is still dropped, by `InvalidateProbeModel()` on an
Agent restart. That is now `internal` rather than `private` so the tests which
used the flush purely to empty the cache drive the real path instead — they
now cover a case that actually occurs in production. Several unrelated doc
comments cited `FlushOptionalCachesAsync` as the canonical CAS example and are
repointed to it.
Tests: the ones that existed only to assert on the removed members are deleted
(3 OpcUaClient, 3 Galaxy, 2 MQTT, 1 MTConnect, 1 AbCip). Worth noting one was
vacuous — `FlushOptionalCachesAsync_resets_footprint_counter` asserted a
footprint of 0 before the flush and 0 after with no discovery in between, so it
would have passed against a flush that did nothing at all.
Full suite green except 7 failures verified identical on master before and
after (4 AbLegacy integration with the compose profile down, 3
Host.IntegrationTests), checked by name rather than assumed.
Docs corrected where they described this as live: `DriverLifecycle.md` (which
carried the #525 placeholder), `drivers/AbCip.md`, `drivers/AbLegacy.md`, and
`v2/driver-stability.md` — whose "polls this every 30 s" + per-driver
`DriverConfig` memory budget were never built as written and are now banner-ed
as design intent rather than description.
Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
Five drivers ignored the config handed to them on reinitialize, serving the
options their constructor captured — and the deployment sealed green anyway.
Fixed on both halves, as chosen.
Seam (load-bearing): DriverSpawnPlanner routes a changed DriverConfig to
ToStop + ToSpawn instead of an in-place delta, making the factory the single
parse authority. This REVERSES the deliberate decision documented at
DriverSpawnPlan.cs:49-50 ("a pure DriverConfig change stays an in-place delta
— no reconnect"). That reasoning was correct about the resilience pipeline and
wrong about the driver. The accepted price is a reconnect per config edit.
Per-driver, and this split was not anticipated:
- Re-parse in place — Modbus, AbLegacy, OpcUaClient. ParseOptions extracted
from each factory, called from InitializeAsync behind a HasConfigBody guard
so "{}" still keeps the constructor options.
- Respawn-only, deliberately NOT re-parsed — Sql and FOCAS. Each builds more
than options from config (Sql's dialect + resolved connection string,
FOCAS's client-factory backend, both injected at construction), so adopting
new options alone would run a NEW tag set against an OLD connection. Half a
re-parse is worse than none. SqlDriver's doc-comment asserted the opposite
premise — "config parsing belongs to the factory, which builds a fresh
instance" — which was false when written and is true only now.
Two green seals removed from ApplyChildDelta: it overwrote the cached Spec
synchronously BEFORE the child dequeued the message, so the host believed the
new config was live and the next reconcile computed no delta, sealing the
drift permanently; and it Tell'd with no Receive<ApplyResult> registered, so a
failed reinit — including Galaxy's deliberate NotSupportedException —
dead-lettered.
Exposed (not created) by the change: a factory throw is a CONFIG error, and
SpawnChild catches it and silently substitutes a stub. Only a brand-new driver
could reach that before; an ordinary config edit can now. Raised Warning ->
Error with an actionable message. It still does not fail the deployment —
doing so would let one malformed driver block a fleet deploy, so that is a
follow-up rather than a drive-by.
Tests: every pre-existing reinit test in these suites passes "{}", the exact
input a guarded re-parser treats as "keep constructor options" — blind to this
defect by construction. New tests pass CHANGED json; the Modbus one was
verified falsifiable by deleting the re-parse (goes red). Two tests asserted
the old behaviour and were rewritten, including the positive control in
DriverHostActorUnreadableArtifactTests, whose observable moved from
UnsubscribeAsync to ShutdownAsync now that teardown happens by stopping the
child rather than emptying its desired set.
Remaining full-suite failures are pre-existing and environmental, verified
identical on the pre-change tree: Host.IntegrationTests (3) and
Driver.AbLegacy.IntegrationTests (4, docker fixture-gated).
Resolve secret:-prefixed Password + UserCertificatePassword through the shared
ISecretResolver, fail-closed on absent, retiring the cleartext-in-DB path. The
driver-registry factory is synchronous (Func<string,string,IDriver>), so resolution
is done lazily in the async session-open (InitializeAsync, before BuildUserIdentity)
rather than at deserialize — mirroring Task 7's Galaxy pattern and matching its
re-resolve-on-reconnect behavior. Both consumers (username Password and the
certificate-password LoadPkcs12 path via BuildCertificateIdentity) see the resolved
connect-scoped options; _options stays raw (secret: refs intact), no long-lived
plaintext field.
Scope corrections vs the plan (verified against v3): the probe is unauthenticated
GetEndpoints-only and never reads either credential, so it is NOT a resolution site
(comment added, no dead code); OpcUaClientDriverOptions was a sealed class, converted
to sealed record for the with-expression (no positional params → identical JSON; no
reference-equality/dict-key/ToString-log usages → no behavior/leak change).
ISecretResolver threaded via factory Register/CreateInstance + DriverFactoryBootstrap
(real resolver from DI); NullSecretResolver null-object backs test/parse paths only,
fail-closed on secret: refs. TDD: 4 helper tests RED→GREEN; 142 OpcUaClient tests pass.
NamespaceMap now carries a RawPath -> upstream node id table built from the
deployed RawTagEntry list (reads each tag's TagConfig.nodeId, threads
WriteIdempotent). Under v3 the read/write/subscribe/history reference handed to
the driver is the tag's RawPath identity; the driver resolves it in two stages:
RawPath -> nodeId string (instance TryResolve) -> live NodeId re-bound against
the session (static TryResolve). Alarm ConditionId + event-history sourceName
stay on the direct session parse (they are upstream node ids, not RawPaths).
- Options: add IReadOnlyList<RawTagEntry> RawTags (Contracts now refs Core.Abstractions).
- Factory: RawTags binds straight into options (no separate DTO); EndpointUrl kept.
- Browser: unchanged (emits neutral BrowseNode DTOs, no TagConfig FullName key).
- Tests: 138 green; new RawPath resolution + factory-binding coverage; migrated
the stale-session ReadRaw test to author a resolving RawTag.
Contracts + Driver + Browser build clean (0 warn). Wave C wires endpoint->DeviceConfig
and the deploy artifact that populates RawTags.
Re-review at 7286d320. -016: BrowseRecursiveAsync now releases the server-side continuation
point on OperationCanceledException (BrowseNext releaseContinuationPoints:true) before
rethrowing (resolves the Browser-002 cross-cutting leak) + TDD.
Closes the code-review coverage gap: AcknowledgeAsync now has its own
swap-across-the-gate regression test (CallAsync lands on the post-gate
session), the subscribe-path coverage gap is documented, and the bounded
fallback drops from 2s to 250ms (the buggy-path signal is a synchronous
pre-await read, so it always wins well inside the bound).
Code-review I2: CoerceDateTime's missing-field sentinel was DateTime.MinValue
(Kind=Unspecified) — a downstream .ToUniversalTime() could shift it; now UTC-kinded.
M4: assert BrowsePath namespace==0 + the sentinel's UTC Kind.
Replace the bare TCP-connect return in OpcUaClientDriverProbe with a real
OPC UA GetEndpoints discovery handshake (mirroring SelectMatchingEndpointAsync
in the driver). TCP preflight still fast-fails closed ports; the handshake
confirms the remote is actually an OPC UA server, so a live-but-rejecting
non-OPC-UA process now reads RED instead of a false-healthy green.
All five suppressed advisories are now resolved at baseline/resolved versions,
so every NuGetAuditSuppress is removed repo-wide:
- System.Security.Cryptography.Xml (GHSA-37gx-xxp4-5rgx / GHSA-w3x6-4m5h-cxqf)
-> fixed by the .NET 10 baseline (10.0.6)
- OPCFoundation Opc.Ua.Core (GHSA-h958-fxgg-g7w3) -> fixed at resolved 1.5.378.106
Two were still live and are now patched via direct security pins:
- OpenTelemetry.Api 1.9.0 -> 1.15.3 (GHSA-g94r-2vxg-569j) pinned in Cluster;
Runtime/ControlPlane/AdminUI + tests inherit via project reference
- Tmds.DBus.Protocol 0.20.0 -> 0.21.3 (GHSA-xrw6-gwf8-vvr9) pinned in Client.UI
Also correct the Historian sidecar runtime comments (x86 -> x64, matching the
csproj PlatformTarget). Solution audit: 0 vulnerable packages; full build clean.
Adds <summary>, <param>, <typeparam>, and <inheritdoc/> tags to public
members surfaced by commentchecker — resolves 5,847 of 5,869 issues
(99.6%) across three /fixdocs passes.
Adds Directory.Packages.props (ManagePackageVersionsCentrally) and
Directory.Build.props (net10.0/nullable/implicit usings/LangVersion latest).
Strips Version attributes from every csproj PackageReference and consolidates
versions into the central file.
Side fixes (necessary to keep the build green on .NET SDK 10.0.105 on macOS):
- Microsoft.CodeAnalysis.CSharp{,.Workspaces}: 5.3.0 -> 5.0.0. The 5.3.0
analyzer DLL references compiler 5.3.0.0 and the local SDK ships compiler
5.0.0.0, producing CS9057 on every project that loaded the Analyzers
output. Master itself was broken on this machine pre-change.
- Server + Server.Tests pin OPCFoundation.NetStandard.Opc.Ua.{Configuration,
Client} to 1.5.374.126 via VersionOverride, matching Opc.Ua.Server's
pin. Mixing 1.5.378.106 Opc.Ua.Core transitively with 1.5.374.126
Opc.Ua.Server breaks CustomNodeManager2 override signatures
(CS0115 on LoadPredefinedNodes/Browse/HistoryRead*) and CS7069 in
the tests. The pin disappears when the legacy Server project is
deleted in Task 56.
- Client.UI + Client.UI.Tests: NuGetAuditSuppress for
GHSA-xrw6-gwf8-vvr9 (Tmds.DBus.Protocol 0.20.0 reaches both projects
transitively from Avalonia.Desktop on Linux/macOS only).
Deviation from the plan: TreatWarningsAsErrors=true is NOT set in
Directory.Build.props because the pre-v2 Admin/Server test projects carry
~240 xUnit1051 analyzer warnings that would fail the build. New v2 projects
opt in via their own csproj; the global flag can return once the legacy
projects are deleted in Task 56.
- Driver.OpcUaClient-011: rewrote the ValueRank comment with the OPC UA
Part 3 constants and an explicit scalar/array boundary at
valueRank >= 0.
- Driver.OpcUaClient-014: track every MonitoredItem.Notification handler
in a MonitoredItemNotificationHandle record; UnsubscribeAsync /
UnsubscribeAlarmsAsync / ShutdownAsync detach the handler before
Subscription.DeleteAsync so the SDK's invocation list no longer keeps
the driver alive.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Map DataTypeIds.Byte to DriverDataType.UInt16 (unsigned family) rather than Int16
(signed family). Update attribute mapping test to assert the correct unsigned mapping
and add Byte/UInt16 to the standard-types theory.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Driver.OpcUaClient-001 — ReadAsync/WriteAsync/DiscoverAsync captured the
session before acquiring _gate, so a reconnect that completed while the
operation was blocked on the gate left the wire call bound to a stale,
closed session. All three now re-read Session (and parse NodeIds) inside
the _gate critical section after WaitAsync returns.
Driver.OpcUaClient-002 — OnReconnectComplete ignored the give-up (null
session) case, permanently wedging the driver with no Faulted signal and
no reconnect loop. The give-up branch now transitions HostState to
Faulted, sets a Faulted DriverHealth with an explanatory message, and
re-arms a fresh SessionReconnectHandler (TryRearmReconnect) against the
last-known session so an always-on gateway self-heals.
Driver.OpcUaClient-003 — BrowseRecursiveAsync discarded browse
continuation points, silently truncating large remote folders.
It now loops on BrowseResult.ContinuationPoint calling BrowseNextAsync
and appending each page until the continuation point is empty.
Driver.OpcUaClient-004 — driver-specs.md §8 namespace handling was
absent. Added NamespaceMap (built from session.NamespaceUris at connect,
rebuilt on reconnect) which persists discovered NodeIds in the
server-stable nsu=<uri>;... form; reads/writes re-resolve that form
against the current session so a remote namespace-table reorder no
longer misaddresses nodes. Added the TargetNamespaceKind option +
UnsMappingTable and ValidateNamespaceKind startup enforcement.
Driver.OpcUaClient-005 — OnKeepAlive read/wrote _reconnectHandler
without a lock, racing the SDK keep-alive timer thread and leaking
handlers. The check-and-set in OnKeepAlive, the take-and-clear in
ShutdownAsync, and the dispose/re-arm in OnReconnectComplete now all
run inside the _probeLock critical section.
Adds OpcUaClientNamespaceTests (11 xUnit + Shouldly regression tests)
covering ValidateNamespaceKind and the NamespaceMap stable encoding.
Reconnect/browse wire paths remain fixture-gated per finding -015.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
Group all 69 projects into category subfolders under src/ and tests/ so the
Rider Solution Explorer mirrors the module structure. Folders: Core, Server,
Drivers (with a nested Driver CLIs subfolder), Client, Tooling.
- Move every project folder on disk with git mv (history preserved as renames).
- Recompute relative paths in 57 .csproj files: cross-category ProjectReferences,
the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external
mxaccessgw refs in Driver.Galaxy and its test project.
- Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders.
- Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL,
integration, install).
Build green (0 errors); unit tests pass. Docs left for a separate pass.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>