Second P1 slice of docs/plans/2026-11-09-out-of-process-script-runner-design.md; still opt-in behind Scripting:Runner=OutOfProcess (InProcess unchanged). - Compiled-PE cache (design §7, §14 #8): Scripting:Worker:PeCacheDir holds <dir>/pe/<id>.pe entries authenticated with HMAC-SHA256 under a per-node random key (<dir>/pe-cache.key, created by the host, 0600/0700 on Unix), handed to the worker in Hello. Entry id = SHA-256(compile fingerprint + kind + source); the fingerprint covers the Roslyn version, the Core.Scripting build (analyzer, wrapper, stack guard), the sandbox reference set and the runtime. Edited, truncated, other-key or renamed entries are rejected, deleted and recompiled; the worker never loads unverified bytes. Pruned by recency at startup (30 d / 50 000). ScriptEvaluator splits into CompileToImage + FromImage. Measured on 40 scripts, restart to every first result: macOS 820 ms no cache / 840 ms empty / 85 ms warm; windev (Windows) 9.5 s / 9.4 s / 1.0 s. - Quarantine race: WorkerConnection runs exit attribution synchronously BEFORE completing the evaluations/loads it held (and before Exited), and the shard passes it straight to the runner — a kill strike is in place before the killed key's slot is released. - Supervision: a dead worker restarts by itself after its backoff; Unavailable outcomes carry ScriptRunOutcome.Recovery (-> VirtualTagEvalResult.RetryWhen) and the VT actor / Calculation driver re-evaluate once against current inputs when it completes. Isolation worker stops after Scripting:Worker:IsolationIdleTimeout (10 min). Keys compiling when a worker dies are suspects too (isolation finds a poison compile and quarantines it). Startup orphan sweep by launch marker: kills only a process whose marker's host is gone and whose pid + start time + image match. - Crash-loop circuit (Scripting:Worker:CircuitOpenAfter, 2 min): runner Unavailable, one Error, evaluations answered at once while shards keep retrying at the cap. - Observability (§10): otopcua.script.runner.state, worker.up/inflight/queue_depth/heap_bytes (shard), ipc.roundtrip + eval.duration (kind), compile{cache}, isolation.suspects, exits reason=idle. `script-runner` health check on the ready tier, at worst Degraded (§14 #12: degraded but still ready). Left on #780: self-contained worker publish, installer (account, pipe ACL, firewall), docker-dev live drill, scripted-alarm seam, the §4.5 per-seam batch submit, the §8 perf harness. Tests: SupervisionTests, PeCacheStoreTests/PeCacheWorkerTests (real workers), ScriptRunnerHealthCheckTests, VT + Calc recovery seam tests; 14 mutations each turned their test red. Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
OtOpcUa
OPC UA server (.NET 10 AnyCPU) that exposes a fleet of industrial drivers as a single OPC UA address space. Drivers ship in-process for AVEVA System Platform Galaxy (via the sibling mxaccessgw repo), Modbus TCP, Siemens S7, Allen-Bradley CIP (ControlLogix / CompactLogix), Allen-Bradley Legacy (SLC 500 / MicroLogix), Beckhoff TwinCAT (ADS), FANUC FOCAS, OPC UA Client (gateway), and MQTT (broker subscribe; Sparkplug B in progress).
A cross-platform client stack (.NET 10) — shared library, CLI, and Avalonia desktop app — connects to any OPC UA server.
Architecture
OPC UA Clients (CLI, Desktop UI, 3rd-party)
|
v
+-------------------------------------+
| OtOpcUa.Server (.NET 10 AnyCPU) |
| address space + capability fan-out|
+-------------------------------------+
| | | | | | | |
Galaxy Modbus S7 AbCip AbLeg TwinCAT FOCAS OpcUaClient MQTT
|
v
mxaccessgw (sibling repo, gRPC)
|
v
MXAccess COM (x86 worker, on AVEVA box)
Galaxy is the only driver with an external runtime: it speaks gRPC to a separately installed mxaccessgw server (sibling repo at c:\Users\dohertj2\Desktop\mxaccessgw\) which owns the MXAccess COM apartment and the x86/STA bitness constraint server-side. Everything in this repo is platform-agnostic .NET 10.
Prerequisites
- .NET 10 SDK (server, drivers, clients all target .NET 10)
- SQL Server reachable for the central config DB
- For Galaxy specifically: a running
mxaccessgwdeployment — see docs/v2/Galaxy.ParityRig.md - For historian read-back / alarm history / continuous historization: a running
ZB.MOM.WW.HistorianGatewaydeployment (the sole historian backend; consumed as theZB.MOM.WW.HistorianGateway.ClientgRPC package). It must runRuntimeDb:Enabled=true+RuntimeDb:EventReadsEnabled=true, and the API key must carryhistorian:read+historian:write+historian:tags:writescopes.
Quick Start
dotnet restore ZB.MOM.WW.OtOpcUa.slnx
dotnet build ZB.MOM.WW.OtOpcUa.slnx
dotnet test ZB.MOM.WW.OtOpcUa.slnx
# Run the server in dev (foreground)
dotnet run --project src/Server/ZB.MOM.WW.OtOpcUa.Host
The server starts on opc.tcp://localhost:4840 with the None security profile. Configure Security.Profiles in src/Server/ZB.MOM.WW.OtOpcUa.Host/appsettings.json to enable Basic256Sha256-Sign or Basic256Sha256-SignAndEncrypt. See docs/security.md.
Install as Windows Services
Production deployment is driven by scripts/install/Install-Services.ps1, which registers the OtOpcUa server service under a chosen service account. Historian support requires a separately deployed ZB.MOM.WW.HistorianGateway and Galaxy support a separately installed mxaccessgw — neither this repo nor the install script provisions them.
.\scripts\install\Install-Services.ps1 `
-InstallRoot 'C:\Program Files\OtOpcUa' `
-ServiceAccount 'DOMAIN\svc-otopcua'
The historian backend is the external ZB.MOM.WW.HistorianGateway (not installed by this script). See the script header and docs/ServiceHosting.md for full options.
Client CLI
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- connect -u opc.tcp://localhost:4840
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- browse -u opc.tcp://localhost:4840 -r -d 3
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- read -u opc.tcp://localhost:4840 -n "ns=2;s=SomeNode"
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- write -u opc.tcp://localhost:4840 -n "ns=2;s=SomeNode" -v 42
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- subscribe -u opc.tcp://localhost:4840 -n "ns=2;s=SomeNode" -i 500
See docs/Client.CLI.md and docs/Client.UI.md.
Documentation
Architecture deep-dives
| Topic | Doc |
|---|---|
| OPC UA server composition, namespace fan-out, Polly invoker | docs/OpcUaServer.md |
| Address space layout | docs/AddressSpace.md |
| Read / Write dispatch (driver vs virtual vs scripted-alarm) | docs/ReadWriteOperations.md |
| Incremental sync (driver-backend rediscovery + config publishes) | docs/IncrementalSync.md |
| Service hosting (Server + Admin; external HistorianGateway backend) | docs/ServiceHosting.md |
| Security (transport, LDAP, certificates) | docs/security.md |
| Redundancy | docs/Redundancy.md |
| Status dashboard | docs/StatusDashboard.md |
Drivers
| Topic | Doc |
|---|---|
| Driver specs (per-driver capability surface, config, addressing) | docs/v2/driver-specs.md |
| Galaxy driver | docs/drivers/Galaxy.md |
| Modbus / S7 / AbCip / AbLegacy / TwinCAT / FOCAS / OpcUaClient / MQTT | docs/drivers/ |
| Galaxy parity rig (mxaccessgw setup) | docs/v2/Galaxy.ParityRig.md |
| Galaxy performance + tracing | docs/v2/Galaxy.Performance.md |
Clients
| Topic | Doc |
|---|---|
| Client CLI | docs/Client.CLI.md |
| Client UI (Avalonia desktop) | docs/Client.UI.md |
v1 archive
The original v1 in-process MXAccess docs (Galaxy.Host topology, Configuration env vars, AlarmTracking, DataTypeMapping, HistoricalDataAccess, Subscriptions, etc.) are preserved under docs/v1/ — historical reference only. PR 7.2 retired the v1 architecture on 2026-04-30; current state is documented in the sections above.
License
Internal use only.