Joseph Doherty f0c6cf9640
v2-ci / unit-tests (push) Has been cancelled
fix(security): running drivers refuse out-of-namespace credential refs at resolve time (#834)
The #815 warn-only compatibility window is over. A running Galaxy driver
(InitializeAsync, every gateway ReopenAsync, the ack fallback password) and a
running OpcUaClient driver (session open) now refuse an out-of-namespace
credential reference with the same CredentialReferenceException that save,
deploy (CredentialReferenceOutOfScope), Test Connect and browse already raise,
before any store / environment / file read and before any endpoint is dialled.
The one existing scope check (CredentialReferences.Parse/ResolveAsync) is now
the only path; nothing new was added.

Removed:
- LegacyCredentialReferenceTracker (Core.Abstractions), its rate-limited WARN
  and the credential-compat:<field> diagnostics entry.
- The per-driver Legacy* resolve methods and every `legacy` parameter
  (GalaxySecretRef, GalaxyAckCredentialResolver, OpcUaUserIdentityFactory,
  OpcUaUserCertificatePaths, OpcUaClientSecretResolution).
- IDriverDiagnostics on GalaxyDriver / OpcUaClientDriver (it only carried the
  tracker's entries).
- The tracker also kept a pre-#836 absolute UserCertificatePath loading on a
  running OpcUaClient driver; that is refused now too.

Preflight / banner decision: KEPT, as a hard error. The Running source
(driver-health credential-compat entries) and CredentialReferenceBannerModel
are gone with the tracker, but the ConfigDb scan still tells an operator
something no other surface does: a Deployed finding is now a driver that is
not connecting, a Draft finding is a deploy the gate will refuse - named
before anyone deploys, e.g. after restoring an old ConfigDb backup or
importing a pre-#815 config. It also carries the #835 cross-instance and
#836/#850 path checks. CredentialReferencePreflightService now logs one Error
per finding (was Warning) with no warn-only wording, and the /raw banner is
alert-danger.

DEV and QA ConfigDbs hold no Galaxy/OpcUaClient driver (checked 2026-11-13);
no production install exists.

Tests: GalaxyDriverLegacyCredentialTests replaced by
GalaxyDriverCredentialScopeTests; new OpcUaClientDriverCredentialScopeTests;
tracker tests in OpcUaClientSecretResolutionTests /
OpcUaClientUserCertificatePathTests deleted; AdminUI preflight tests drop the
Running/banner-model cases and assert Error level. Against the old code the
new refusal tests fail (Galaxy 5/6, OpcUaClient 4/5; the two positive controls
pass on both).

docs/security.md: the migration table now says running drivers refuse; the
warn-only section is replaced by "The compatibility window is over".

Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
2026-11-13 02:06:43 -05:00
Pin libplctag ab_server to v2.6.16 — real release tag + SHA256 hashes for all three Windows arches. Closes the "pick a current version + pin" deferral left by the #180 PR docs stub. Verified the release lands ab_server.exe inside libplctag_2.6.16_windows_<arch>_tools.zip alongside plctag.dll + list_tags_* helpers by downloading each tools zip + unzip -l'ing to confirm ab_server.exe is present at 331264 bytes. New ci/ab-server.lock.json is the single source of truth — one file the CI YAML reads via ConvertFrom-Json instead of duplicating the hash across the workflow + the docs. Structure: repo (libplctag/libplctag) + tag (v2.6.16) + published date (2026-03-29) + assets keyed by platform (windows-x64 / windows-x86 / windows-arm64) each carrying filename + sha256. docs/v2/test-data-sources.md §2.CI updated — replaces the prior placeholder (ver = '<pinned libplctag release tag>', expected = '<pinned sha256>') with the real v2.6.16 + 9b78a3de... hashes pinned table, and replaces the hardcoded URL with a lockfile-driven pwsh step that picks windows-x64 by default but swaps to x86/arm64 by changing one line for non-x64 CI runners. Hash-mismatch path throws with both the expected + actual values so on the first drift the CI log tells the maintainer exactly what to update in the lockfile. Two verification notes from the release fetch: (1) libplctag v2.6.16 tools zips ship ab_server.exe + plctag.dll together — tests don't need a separate libplctag NuGet download for the integration path, the extracted tools dir covers both the simulator + the driver's native dependency; (2) the three Windows arches all carry ab_server.exe, so ARM64 Windows GitHub runners (when they arrive) can run the integration suite without changes beyond swapping the asset key. No code changes in this PR — purely docs + the new lockfile. Admin tests + Core tests unchanged + passing per the prior commit.
2026-04-20 00:04:35 -04:00

OtOpcUa

OPC UA server (.NET 10 AnyCPU) that exposes a fleet of industrial drivers as a single OPC UA address space. Drivers ship in-process for AVEVA System Platform Galaxy (via the sibling mxaccessgw repo), Modbus TCP, Siemens S7, Allen-Bradley CIP (ControlLogix / CompactLogix), Allen-Bradley Legacy (SLC 500 / MicroLogix), Beckhoff TwinCAT (ADS), FANUC FOCAS, OPC UA Client (gateway), and MQTT (broker subscribe; Sparkplug B in progress).

A cross-platform client stack (.NET 10) — shared library, CLI, and Avalonia desktop app — connects to any OPC UA server.

Architecture

                      OPC UA Clients (CLI, Desktop UI, 3rd-party)
                                       |
                                       v
                    +-------------------------------------+
                    |  OtOpcUa.Server (.NET 10 AnyCPU)    |
                    |   address space + capability fan-out|
                    +-------------------------------------+
                    |    |    |    |    |    |    |    |
          Galaxy Modbus S7 AbCip AbLeg TwinCAT FOCAS OpcUaClient MQTT
                |
                v
       mxaccessgw (sibling repo, gRPC)
                |
                v
     MXAccess COM (x86 worker, on AVEVA box)

Galaxy is the only driver with an external runtime: it speaks gRPC to a separately installed mxaccessgw server (sibling repo at c:\Users\dohertj2\Desktop\mxaccessgw\) which owns the MXAccess COM apartment and the x86/STA bitness constraint server-side. Everything in this repo is platform-agnostic .NET 10.

Prerequisites

  • .NET 10 SDK (server, drivers, clients all target .NET 10)
  • SQL Server reachable for the central config DB
  • For Galaxy specifically: a running mxaccessgw deployment — see docs/v2/Galaxy.ParityRig.md
  • For historian read-back / alarm history / continuous historization: a running ZB.MOM.WW.HistorianGateway deployment (the sole historian backend; consumed as the ZB.MOM.WW.HistorianGateway.Client gRPC package). It must run RuntimeDb:Enabled=true + RuntimeDb:EventReadsEnabled=true, and the API key must carry historian:read + historian:write + historian:tags:write scopes.

Quick Start

dotnet restore ZB.MOM.WW.OtOpcUa.slnx
dotnet build ZB.MOM.WW.OtOpcUa.slnx
dotnet test ZB.MOM.WW.OtOpcUa.slnx

# Run the server in dev (foreground)
dotnet run --project src/Server/ZB.MOM.WW.OtOpcUa.Host

The server starts on opc.tcp://localhost:4840 with the None security profile. Configure Security.Profiles in src/Server/ZB.MOM.WW.OtOpcUa.Host/appsettings.json to enable Basic256Sha256-Sign or Basic256Sha256-SignAndEncrypt. See docs/security.md.

Install as Windows Services

Production deployment is driven by scripts/install/Install-Services.ps1, which registers the OtOpcUa server service under a chosen service account. Historian support requires a separately deployed ZB.MOM.WW.HistorianGateway and Galaxy support a separately installed mxaccessgw — neither this repo nor the install script provisions them.

.\scripts\install\Install-Services.ps1 `
    -InstallRoot 'C:\Program Files\OtOpcUa' `
    -ServiceAccount 'DOMAIN\svc-otopcua'

The historian backend is the external ZB.MOM.WW.HistorianGateway (not installed by this script). See the script header and docs/ServiceHosting.md for full options.

Client CLI

dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- connect -u opc.tcp://localhost:4840
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- browse  -u opc.tcp://localhost:4840 -r -d 3
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- read    -u opc.tcp://localhost:4840 -n "ns=2;s=SomeNode"
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- write   -u opc.tcp://localhost:4840 -n "ns=2;s=SomeNode" -v 42
dotnet run --project src/Client/ZB.MOM.WW.OtOpcUa.Client.CLI -- subscribe -u opc.tcp://localhost:4840 -n "ns=2;s=SomeNode" -i 500

See docs/Client.CLI.md and docs/Client.UI.md.

Documentation

Architecture deep-dives

Topic Doc
OPC UA server composition, namespace fan-out, Polly invoker docs/OpcUaServer.md
Address space layout docs/AddressSpace.md
Read / Write dispatch (driver vs virtual vs scripted-alarm) docs/ReadWriteOperations.md
Incremental sync (driver-backend rediscovery + config publishes) docs/IncrementalSync.md
Service hosting (Server + Admin; external HistorianGateway backend) docs/ServiceHosting.md
Security (transport, LDAP, certificates) docs/security.md
Redundancy docs/Redundancy.md
Status dashboard docs/StatusDashboard.md

Drivers

Topic Doc
Driver specs (per-driver capability surface, config, addressing) docs/v2/driver-specs.md
Galaxy driver docs/drivers/Galaxy.md
Modbus / S7 / AbCip / AbLegacy / TwinCAT / FOCAS / OpcUaClient / MQTT docs/drivers/
Galaxy parity rig (mxaccessgw setup) docs/v2/Galaxy.ParityRig.md
Galaxy performance + tracing docs/v2/Galaxy.Performance.md

Clients

Topic Doc
Client CLI docs/Client.CLI.md
Client UI (Avalonia desktop) docs/Client.UI.md

v1 archive

The original v1 in-process MXAccess docs (Galaxy.Host topology, Configuration env vars, AlarmTracking, DataTypeMapping, HistoricalDataAccess, Subscriptions, etc.) are preserved under docs/v1/ — historical reference only. PR 7.2 retired the v1 architecture on 2026-04-30; current state is documented in the sections above.

License

Internal use only.

S
Description
No description provided
Readme 53 MiB
Languages
C# 71.1%
JavaScript 24.1%
HTML 2.3%
Python 0.9%
PowerShell 0.8%
Other 0.7%