- IMPORTANT: a successful probe records the PLC's ADS state; a PLC not in Run
keeps the driver Degraded with 'PLC in {state}' while LastSuccessfulRead
still advances (the device answered). RecordDeviceAnswered never restores
Healthy while any device is out of Run.
- Health is per device, rolled up worst-of: a comms fault is remembered on the
device it was seen on and only that device answering clears it (device A
answering no longer clears device B's fault).
- Refused (non-comms) dead registrations back off 30 s doubling to 10 min and
are re-armed by a symbol-version change or retried by the reconnect replay;
comms-class failures keep the every-tick retry. A retry whose failure class
changes republishes the tag's status, once.
- Bit-RMW gates are kept across generations and teardowns (never cleared).
- ShutdownAsync honours its CancellationToken: it stops waiting, finishes the
bookkeeping and throws OperationCanceledException.
- Remarks on why a superseded InitializeAsync throws OperationCanceledException.
- REAL / LREAL values (scalar or array element) outside the target range are
OverflowException -> BadOutOfRange instead of being written as Infinity.
- String / array write encoding factored into AdsTwinCATClient.PlanStringWrite
/ PlanArrayWrite; the fake runs them so a driver-level test covers the real
encode path against a fake resolved symbol.
- Timing-fragile tests use condition waits / measured probe-tick windows; the
dispose-during-shutdown test asserts ordering with a 1 s bound.
Refs #739
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Native-subscribe isolation of an unknown symbol, LastSuccessfulRead advance
from pushes alone, a WORD bit write flipping exactly one bit (bit 16
refused), a whole-array REAL write round-trip (length mismatch refused) and a
STRING(80) write round-trip (overflow refused). Every writing case restores
the seed it touched. Skipped without the TwinCAT XAR fixture.
Refs #739
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The poll engine already builds a per-cycle batch; TwinCAT now forwards it as
OnDataChangeBatch, so DriverInstanceActor gets one message per poll cycle
instead of one per changed tag. Because the actor subscribes ONLY the batch
event of a batch-capable driver, every native-path data change (pushes, the
BadNodeIdUnknown / refusal / unavailable snapshots) is raised through a single
RaiseDataChange that fires both the per-tag event and a fresh one-item batch.
Refs #739
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
- Device and tag tables are build-and-swap: InitializeAsync builds a fresh
generation and publishes it by one swap under a lifecycle lock, then
releases the replaced generation; teardown swaps in empty tables. A
retained poll loop never sees a table mid-Clear (it used to read
_tagsByRawPath while a re-init only ever added to it), and each device
set is released by exactly one caller.
- A lifecycle generation makes an InitializeAsync overtaken by a shutdown
(or a newer init) release what it built instead of installing it - the
Lane A abandoned-init-overlaps-shutdown case.
- ShutdownAsync joins all probe loops together within 2 s (it awaited each
unbounded - a probe wedged in the blocking ADS Connect hung the actor's
teardown) in parallel with the poll-engine dispose, the whole bounded at
4.5 s; DisposeAsync may run concurrently and returns at once. A connect
that completes on a released device disposes its client.
- Releasing a generation disposes its native registrations, so a direct
re-init no longer leaves live notifications bound to dead DeviceStates.
- Connect gates and RMW semaphores are no longer disposed under in-flight
users (no kernel handle is ever allocated); a fault on a released device
is not recorded as driver health.
- The notification channel counts DropWrite overflows
(ITwinCATClient.DroppedNotificationCount); the probe tick warns with the
delta. A queued value whose registration was disposed is purged in the
client dispatch loop and dropped driver-side for any client.
Refs #739
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Array tags were advertised writable but every write threw InvalidCastException
in ConvertForWrite (reported BadTypeMismatch); STRING writes went through the
Beckhoff marshaller with no length check against STRING(n) and the host's
ANSI code page, which the read side deliberately avoids.
- Array write: TwinCATArrayCodec.ToWriteElements converts exactly ArrayLength
elements to the declared type (CLR lists convert - ScadaBridge writes int[]
to Int16 nodes; a length mismatch or out-of-range element is BadOutOfRange, a
scalar value BadTypeMismatch) before any wire traffic; the ADS client plans
the layout from the resolved PLC array (TwinCATTypeGuard.CheckArray, as the
read does), encodes with TwinCATArrayCodec.Encode - the exact inverse of
Decode - and writes the raw bytes (new ITwinCATClient.WriteArrayAsync).
- STRING / WSTRING write: encoded at the PLC's declared width by
TwinCATStringCodec.EncodeString/EncodeWString (Windows-1252 or UTF-8 per
target, NUL-padded, strict: an over-long value or unrepresentable character
is OverflowException -> BadOutOfRange) and written as raw bytes.
- TwinCAT CLI read/write gain --array-length (+ --separator) for the hardware
gate.
Refs #739
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The bit write read and wrote the parent word as a 32-bit UDInt with no parent
check: a bit beyond a 16-bit parent was written into neighbouring bytes, and a
signed parent with its sign bit set read back >= 2^31, so the checked
conversion turned any bit write into BadOutOfRange.
The write now goes through ITwinCATClient.WriteBitAsync: the ADS client
resolves the parent symbol, checks the bit against it (TwinCATBitAccess.
CheckParent, as the notification path already did), reads exactly
parent.ByteSize raw bytes, flips one bit (TwinCATBitAccess.ApplyBitWrite) and
writes the bytes back by index group/offset or variable handle. A bit beyond
the parent is BadOutOfRange, a non-integer parent BadTypeMismatch, a short
parent read BadCommunicationError (never written back), all without a health
write. The per-parent RMW lock stays in the driver.
Refs #739
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
CompleteRead logged a Warning for every non-Good status on every poll and
latched Degraded for all of them. Now a bad tag warns once per bad episode
(re-armed when it reads Good, and on re-initialise), a comms-class status
(BadCommunicationError / BadTimeout) degrades with LastSuccessfulRead
preserved, and any other status - the device answered and refused this tag -
advances LastSuccessfulRead with no state change. Read-path exception
handlers now go through MarkCommsFault, so they never downgrade Faulted.
Refs #739
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
In native-notification mode LastSuccessfulRead never moved past the init
stamp, so one Degraded write on a connection older than 90 s latched the
comms-loss watchdog into a full reconnect (every notification on every device
deleted and re-registered). Conversely an unreachable AMS router was swallowed
by the probe and never left Healthy.
- a native push and a successful probe now stamp LastSuccessfulRead (throttled
to one health record per 250 ms) and restore Healthy unless a device is still
probe-unreachable;
- 3 consecutive failed probe ticks write Degraded with the stamp preserved;
- a NotSupportedException write is BadNotSupported with no health write (#611);
- a reconnect replay the PLC refuses republishes the refusal's status without
degrading (it used to report BadCommunicationError + Degraded on every
reconnect for a correctly-isolated type-mismatch tag).
Refs #739
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Native subscribe was all-or-nothing: any registration failure other than a
type refusal disposed every registration and rethrew, so one typo'd symbol or
one unreachable PLC in a multi-device driver served zero data, churned
register/delete every reconcile tick, and left health Healthy.
Now each registration fails on its own: a refusal (the device answered: symbol
not found, PLC not ready, type mismatch) publishes its status with no health
write; any other per-tag failure publishes BadCommunicationError and degrades;
a connect failure marks the device unreachable for the rest of the call and
stores its tags as dead intents. Every failed tag is kept as a dead intent that
the probe-tick retry and the reconnect replay re-register. The ADS client now
classifies a failed symbol resolve / AddDeviceNotification by status instead of
throwing InvalidOperationException for all of them. Cancellation still tears
the partial subscription down.
Refs #739
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The native subscribe path silently skipped a reference it could not resolve
(unknown RawPath, or a tag routed to an unconfigured device), leaving the node
on whatever status the server seeded. It now publishes one BadNodeIdUnknown
snapshot, matching the poll path.
Refs #739
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
GalaxyTelemetryTests (ActivityListener) and GatewayGalaxyDataWriterFailClosedTests
(MeterListener, filtered only by meter and instrument name) observe every Galaxy span or
measurement in the process. They now run in a collection with parallelization disabled
(F-FU6), because a parallel driver test, or its background probe seed, polluted their counts.
The stream-cancel assertion in GalaxyDriverShutdownTests goes back to a bounded wait: the
instantaneous IsCompleted check introduced in round 1 was racy.
Refs #735
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Review fix round 2 for lane F:
- N1: the init platform seed no longer runs inline under the init token. Galaxy's Tier-A
Initialize budget is 5 s, and a cold gateway DiscoverHierarchy can spend all of it, so the
OperationCanceledException rethrow failed init, opened the Initialize breaker and cost a full
rebuild per retry. InitializeAsync now only resolves the platform source (no network) and
queues a background seed tied to a per-runtime CTS that the teardown cancels. A result that
lands after its runtime was torn down is discarded.
- N2: the seed worker serves the runtime that is live when each pass STARTS, so a request made
under a new runtime while a stale pass is in flight always gets a pass of its own.
- N3: SubscribeAsync and the subscribe-once read capture the runtime generation before
SubscribeBulk and register only if it is unchanged, atomically with the teardown's registry
Clear (_registryGate). On a mismatch they release the handles and fail the call. Re-subscribe
Rebind uses the same gate, and the production rebuild clears the registry unconditionally.
- PerPlatformProbeWatcher re-checks its stop after the SubscribeBulk await, atomically with
the record and publish. A pass that straddles StopAsync releases the handles it acquired
instead of writing the probe entry back into a cleared registry.
Refs #735
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The fixture wedged EVERY write on one shared token-ignoring release gate, so
the later same-tag write was also hung, and the 300 ms pessimistic bound
abandoned it while the test was still polling before ReleaseWrites(). Its
reason was "write did not complete within" (the bound), not "queued for" (the
queue budget), and it had already entered the driver, so the tag had been
released. The release path is correct. Only the first write now hangs, and
later writes complete at once.
The abandon reason formatted the bound with TotalSeconds:F0, which printed a
300 ms bound as "0s". It now uses milliseconds, and the test asserts it.
Refs #731
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The writer concurrency fake parks on its release signal (the 300 ms delay could release the
gate early on a starved pool), the supervisor test's cross-thread hold flag is Volatile, and
the EffectiveTimeout doc now states the 1 s floor the code and tests implement.
Refs #735
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Review fix round 1 for lane F:
- The ScanState probe watcher is seeded at InitializeAsync from a platform-only
DiscoverHierarchy query (IGalaxyPlatformSource / GatewayGalaxyPlatformSource over the owned
repository client) and re-seeded on every deploy-watcher rediscovery. The runtime never
calls DiscoverAsync on a live driver, so per-platform host status was unreachable in
production. A failed fetch logs a Warning and never fails init; re-seeds coalesce so a
deploy during an in-flight pass still gets a pass that starts after it.
- EnsureEventPumpStarted refuses while the runtime is stopping, BEFORE reusing the live pump
(that pump belongs to the dying subscriber), and the production rebuild disposes any stale
pump before wiring the new subscriber.
- TeardownRuntimeAsync closes the MX session under the caller's token linked with a 5 s
SessionCloseDeadline, so a blackholed gateway cannot hold DriverInstanceActor.PostStop for 30 s.
- A runtime generation counter, bumped by every teardown, is re-checked before each Rebind
in ResubscribeAllAsync, so a replay-gap re-snapshot that straddles a teardown cannot
resurrect handles into the cleared registry.
Refs #735
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The SDK's DisposeAsync closes with no token, i.e. under the 30 s DefaultCallTimeout, so a
blackholed gateway parked the driver's teardown for the whole of it. CloseAsync(ct) runs the
close under the caller's token, drops the channel on a cancelled/failed close (the gateway
reaps the session on its idle lease) and leaves the session re-openable. A close followed by
the final dispose closes the gateway session once.
Refs #735
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
- RunWriteAsync wraps the invoker call in WaitAsync(writeTimeout) (Props,
default 10 s = 2x the 5 s write cap): a token-ignoring hung write now
answers BadTimeout, releases its slot and tag, and its orphan outcome
is observed and discarded - later writes to that tag reach the device.
- WriteCompleted carries the launching incarnation (from the process-wide
generation source); a late completion from a previous incarnation after
a supervision restart is ignored instead of freeing the new
incarnation's slot/tag.
- Test: a hung token-ignoring tag-a write is abandoned and a later tag-a
write reaches the device while the abandoned one is still inside it.
Refs #731
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
- GatewayHistorianDataSource.ReadRawWindowAsync keeps the cap + 1 probe budget
(budgetCap) separate from the client's cap: a strict-ceiling or crowding
refusal now reports Limit = the server cap that applied and advises setting
NumValuesPerNode at or below it (it said "lower NumValuesPerNode" with
Limit = cap + 1 to a client that sent 0).
- Fuzz: the oracle-source over-cap assertion was vacuous (cap 0 never counts);
it now checks no reverse window reached the forward-only shape. Class docs
name the post-floor cap set (3 ... 1000) and distinguish NumValuesPerNode
1 / 2 from the smallest server cap.
- HistoryPaging.IsFullPage doc says it judges the REQUEST cap (page + ties +
lookahead), which is finite under any limit; AdvertiseMaxReturnDataValues
swallows any exception (returns false for the caller to log), as its doc
promised.
Refs #736
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
- Writes: a second write to a tag already inside the driver waits in the
queue behind it (_tagsInFlight) while other tags still run under the
cap of 4; queued writes are stamped and failed BadTimeout at dequeue
once older than the 8 s host Ask budget (Props queuedWriteBudget)
instead of being written late.
- Initialise attempts are bounded pessimistically (initializeTimeout,
default 30 s = 2x Tier C) on top of the invoker's token-only timeout:
an overrun is logged as abandoned, reported InitializeFailed so the
retry loop continues, and its late result is dropped by generation.
Generations come from a process-wide Interlocked counter so a prior
incarnation's late result cannot collide (F6).
- PostStop shares one shutdownTimeout budget across shutdown + dispose.
- TelemetryDialSupervisor cancels the establishment deadline on
StreamStopped; FleetDiagnosticsClient builds the ActorSelection inside
the try (a malformed node degrades to "unavailable"); the diagnostics
page labels the column "Last health publish".
- Tests: same-tag serialisation with a distinct-tag positive control;
stale queued write BadTimeout; token-ignoring hung init -> later
attempt connects; stopwatch assertion demoted to a ceiling.
Refs #731
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
- NodeManagerHistoryReadRawCapFuzzTests: 10k seeds (env OTOPCUA_PAGING_FUZZ_ITERATIONS)
through a real SDK node manager against wire-faithful fakes of SqlServer / QuestDB /
Gateway that enforce the backend half of the cap; random series with ties, random
windows (empty, on/past a tie, between samples, forward/reverse/end-only, bounds),
N in {0,1,2,small,huge}, cap in {off,3..1000}, tie budget {3,8,65536}. Pages must
concatenate to the cap-off one-shot answer (checked against the series), terminate
within values + 2 (+ one empty step per oversized boundary cluster), never exceed
the cap, never ask the backend for 0 / over-cap; refusals only past the budget.
- HistoryPaging.AdvertiseMaxReturnDataValues writes HistoryServerCapabilities/
MaxReturnDataValues (i=11273), read back through the SDK master node manager.
- MinMaxRawValuesPerRead raised to 3: at 2 a resumed page has no room (value + its
boundary tie + lookahead) and every value cost an empty page + CP (seed 15).
- RawPageLimit rows pin the default-cap arithmetic (9 999 first page, 9 998 resumed).
Fuzz findings recorded as follow-ups: a bounded read whose data fits one page
returns cap + 1 (end bound fitted against N, not the cap; node manager, F2);
the Gateway walk-back's cost on a sparse series under a tiny tie budget is
pre-existing (seed 320: 82 reads uncapped, 93 capped).
Refs #736
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
DriverInstanceDiagnostics.Name carries the string driver-instance id
(what /hosts, telemetry and the artifact key on) and DriverInstanceId
the DB row Guid; the wire record has no slot for the authored display
name. The write-cap test asserts entry order per slot pair instead of
completion order of two concurrent writes.
Refs #731
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
DriverHostActor wraps the health publisher it hands its children in a
ChildHealthLedger (last snapshot per driver id, forwarded to the real
publisher), so GetDiagnostics now answers with each child's row id,
authored name, last-published state, device counts (host statuses when
the driver probes hosts, else one device) and last-change time — instead
of Guid.Empty / "Spawned" / 0 / now. Entries are forgotten on StopChild
and operator Restart.
IFleetDiagnosticsClient gains its first consumer: the new
/fleet/diagnostics page (node selector + ?node= query, revision,
running-from-cache notice, per-driver table). FleetDiagnosticsClient
logs the degrade-to-empty path at Warning.
Review ref: 02/U1.
Refs #731
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Review 2026-10-21 G-5, G-6, G-8 ("wire them all").
- G-5: GatewayGalaxyHierarchySource now pages the DiscoverHierarchy RPC
itself (DiscoverHierarchyRawAsync) at Repository.DiscoverPageSize. The
mxaccessgw client's typed DiscoverHierarchyAsync overloads hard-code a
5000-row page and DiscoverHierarchyOptions carries no page size, so the
authored knob reached nothing; the raw request takes page_size on the
wire, so it is honoured here (non-positive → 5000). The loop keeps the
client's repeated-page-token guard.
- G-6: GalaxyDriverProbe reads ProbeTimeoutSeconds from the config and
runs under min(caller budget, configured cap) — the knob can shorten a
probe, never extend it past the host's budget. The TCP preflight now
shares that deadline instead of hanging on the caller's token alone.
- G-8: GatewayGalaxyDataWriter runs a batch as one lane per distinct tag,
concurrently and bounded at 8 (MaxConcurrentWriteLanes); same-tag
writes keep their authored order inside one lane and results land at
their request's index. Acks stay serial by design.
- GalaxyDriverForm: help text now says what the two knobs actually do.
Refs #735
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
CallTimeoutSeconds was bound, defaulted and documented but consumed
nowhere. TelemetryDialSupervisor now arms a per-generation deadline on
every dial: a dial that has delivered no event by the deadline is
cancelled and treated as a transport failure (reconnect with a failure
streak). A live node replays its snapshots on subscribe, so this bites
only a dial that never connects (a black-holed host, where the socket
connect has no timeout). An established stream is deliberately not
bounded — the wire has no heartbeat, keepalive pings own its liveness.
Review ref: 02/U2.
Refs #731
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
- DriverHostActor.StopChild removes the driver's _lastReprovisionUtc stamp
(and its deferred-reprovision timer): the map grew per removed id and a
re-added driver inherited a backoff it never earned (02/L2).
- Stale now registers explicit drops for AttributeValueBatchPublished,
AttributeAlarmPublished, ArtifactForApply and ApplyWedged instead of
letting them hit Unhandled (02/H5).
- DbHealthProbeActor runs its SELECT on the thread pool and pipes the
outcome back (single-flight), with a 2 s command timeout on relational
providers, so a hung SQL Server no longer pins the actor thread and the
cached GetStatus answer stays reachable (02/P7).
- TelemetryLocalHub eviction tombstones are timestamped and swept past a
10 min TTL on the next Evict; a TimeProvider ctor is the test seam (02/L4).
- Tests: ValuePublishes.Single helper replaces the per-value
AttributeValuePublished in CalculationDependencyFlowTests (02/U4, test
half; the production receive is owned by Lane E).
- R05/8 audit: PollGroupEngine.Unsubscribe has no production caller; every
driver already uses UnsubscribeAsync (no change).
Refs #731
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Review 2026-10-21 G-4, G-7, G-11, G-10.
- G-4: PerPlatformProbeWatcher publishes its probe handles into the
driver's SubscriptionRegistry under the reserved ProbeSubscriptionId
(-1), so the EventPump's fan-out finally reaches the watcher — every
ScanState event used to be dropped as "stale after unsubscribe" and
per-platform host status never updated. ResubscribeAllAsync delegates
the reserved entry to the watcher's new ResubscribeAsync, so the probe
survives a reconnect; StopAsync removes the entry. Probe traffic is
routed by the reserved handle and never reaches the public OnDataChange.
The watcher is also built on the seam path (subscriber only), which is
what makes the wiring testable without a gateway.
- G-7: GalaxyDiscoverer.DiscoverAsync returns the hierarchy it fetched and
the driver selects its $WinPlatform/$AppEngine probe targets from that
same sweep instead of asking the gateway for the whole galaxy twice.
- G-11: OnPumpDataChange stamps LastSuccessfulRead from inbound stream
data, throttled (1 s default), so the comms-loss watchdog has honest
liveness evidence under a Degraded supervisor.
- G-10: an EventPump dispatch-loop exit that is not a cancellation now
reports a stream fault so the supervisor recreates the pump, instead of
leaving a deaf pump reporting Healthy.
Refs #735
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
WriteAttribute was a ReceiveAsync, suspending the child's mailbox for the
whole device round-trip (up to 5 s): writes serialised, the second of two
operator writes to a slow device missed the host's 8 s Ask and was
reverted although the device took it, and every data change queued behind
the write. Writes are now a synchronous Receive that launches the device
call on the thread pool (sender captured, reply from the task, slot freed
by a self-sent WriteCompleted) under a per-driver cap (default 4; excess
writes queue in order). Queued writes fail fast on every exit from
Connected. Subscribe/unsubscribe stay ReceiveAsync.
Review ref: 02/P2.
Refs #731
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
GalaxyDriver.ShutdownAsync was a no-op: the MX session, both owned gRPC
channels, the EventPump, the alarm feed, the DeployWatcher, the probe
watcher and the reconnect supervisor were released only by DisposeAsync,
which the host never calls — one leaked gateway session per respawn,
removal and /raw browse, and a watchdog Shutdown→Initialize that neither
tore down nor rebuilt anything (review 2026-10-21 G-1, G-2, G-9, G-3).
- ShutdownAsync and DisposeAsync share one ordered TeardownRuntimeAsync
(supervisor first, then deploy/probe watchers, pump, alarm feed,
session, channels); owned seams are nulled so the next InitializeAsync
rebuilds; injected seams survive a shutdown and drop only on the final
dispose. Lifecycle calls are serialised behind a gate.
- A failed production connect releases its partial runtime (no orphaned
client per watchdog retry) and lands Faulted before and after.
- StartDeployWatcherAsync stops the previous watcher before starting a
replacement, and now starts on a production instance's FIRST
InitializeAsync (the old guard returned whenever discovery had not run
here, which on a runtime instance is always).
- ReconnectSupervisor releases each cycle's CancellationTokenSource when
its loop exits and gains an awaitable StopAsync; PerPlatformProbeWatcher
gains an awaitable StopAsync.
- EventPump treats any exception under cancellation as a clean stop, so a
teardown never wakes the supervisor.
- Internal seams for tests: an IGalaxyDeployWatchSource ctor parameter and
a session-open override forwarded to the owned GalaxyMxSession.
Refs #735
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Review R08:1.1: an uncapped HistoryRead-Raw (NumValuesPerNode = 0) read a
tag's whole window into memory on every backend (SQL TOP(int.MaxValue),
QuestDB LIMIT, Gateway max_values = int.MaxValue + a second snapshot copy).
New ServerHistorian:MaxRawValuesPerRead (default 10 000; <= 0 unbounded with
a Validate() warning; 1 raised to 2). Each backend data source takes it,
reports it as IHistorianDataSource.MaxRawValuesPerRead (the Gateway: min
with a strict gateway's learned ceiling), so the node manager's existing
RawPageLimit paging serves N = 0 and N > cap as pages of at most the cap
with a continuation point. Independently, a backend raw read asking for 0
or more than the cap reads cap + 1 rows and is REFUSED
(HistoryReadLimitExceededException => BadTooManyOperations) when the window
holds more - never answered truncated, since the server's paging reads a
short answer as the last page. Bound through the Host registry, the
SqlServer/QuestDb providers and GatewayHistorian.CreateDataSource.
Tests: options (default/binding/warnings), provider binding, Gateway unit +
through a real SDK node manager (uncapped -> 999/998/998/605 + CPs), and a
conformance case for the SQL backends.
Refs #736
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The Reconnecting retry timer started a new ShutdownAsync + InitializeAsync
pair on every tick whether or not the previous attempt had finished; the
generation token only discarded the older RESULT, so with an Initialize
bound longer than the cadence the teardown ran underneath an attempt still
inside the driver (the dispose-before-overwrite race). An _initInFlight
gate, cleared by the piped InitializeSucceeded/Failed, skips a tick while
an attempt is running; the pre-reconnect teardown is bounded by the
shutdown timeout; PostStop cancels an in-flight attempt before shutting
the driver down.
Review ref: 02/H2.
Refs #731
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
DriverInstanceActor.PostStop now bounds IDriver.ShutdownAsync by a
shutdownTimeout (default 5 s, logged on overrun) and then disposes the
driver (IAsyncDisposable preferred, else IDisposable) — but only on a
real stop. PreRestart flags the restart so the PostStop it triggers
skips the dispose, because a supervision restart re-uses the same
driver object (Props closure) and the host re-initialises it.
DiscoveryDriverBrowser disposes its throwaway capture/probe driver
after the bounded shutdown, including after a failed or timed-out one.
Review refs: 02/L1, 02/P4, 06/G-1 (host context), 07/L2.
Refs #731
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Keeps the root CLAUDE.md lean by lazy-loading per-area detail (drivers, topology,
data-plane auth, alarms, historian) only when matching files are touched.
Clears CommentChecker findings in src/ (3,280 -> 209, the remainder being false
positives like PLC-5/IEEE-754/M0.0) by adding missing summaries/params/returns,
normalising inheritdoc usage, and removing Gitea/review tracking IDs while keeping
the rationale they annotated. Comment-only: comment-stripped sources are identical
to the parent commit.