Joseph Doherty 9aff90f884 fix(opcuaclient): never pass checkDomain for a None endpoint; document both SDK check sites (#816 review)
SDK 2.0.1 checks the server host name in TWO places: Session.OpenAsync (after
the chain is trusted) and DefaultSessionFactory.CreateChannelAsync, against the
certificate in the GetEndpoints reply and before any security-mode test. opc-plc
sends a certificate on its None endpoint, so `connect -u
opc.tcp://10.100.0.35:50000 --validate-host-name` was refused on an
unauthenticated channel, where a host check proves nothing.

All three call sites now pass checkDomain only when the selected endpoint's
SecurityMode != None: OpcUaEndpointSelection.CheckDomainFor for the driver
(OpenSessionOnEndpointAsync, so the failover sweep too) and the AdminUI browser;
the same expression in Client.Shared ConnectToEndpointAsync (shared by
failover). New live tests: driver None + flag on vs :50000 reads; browser None +
flag on vs the NAT fixture browses; the secure + flag refusals still hold.

Docs: name both check sites; a zone-qualified IPv6 host never matches (FindDomain
compares the zone too), so link-local needs validateServerHostName=false; the
match is loose (first label alone, subject DC= parts count, no wildcards), which
caveats the CA recommendation.
2026-11-11 01:53:01 -05:00
Joseph Doherty ae91e6b7f7 feat(opcuaclient): opt-in server-certificate host-name check; NAT fixture keeps its PKI (#816, #818)
#816 finding: the SDK checks that the server certificate names the host only
when a session is created with checkDomain:true. The driver, the AdminUI
browser and Client.Shared all called the 8-argument
DefaultSessionFactory.CreateAsync, which forwards checkDomain:false — so no
host-name check ever ran (why a trusted NAT cert for *.invalid browsed fine
over an IP in #813). When enabled the SDK (Session.OpenAsync ->
ValidateDomains -> FindDomain) compares ConfiguredEndpoint.EndpointUrl.IdnHost
— the CONFIGURED host, because OpcUaEndpointSelection/EndpointSelector
rewrote the advertised one — against the cert's DNS/IP SANs; secured
sessions only, and the auto-accept handler accepts a mismatch.

Policy: certificateValidation.validateServerHostName, tri-state. Unset =
OpcUaCertificateValidationOptions.DefaultValidateServerHostName = false, the
pre-#816 behaviour, so nothing changes on upgrade; true = validate the
configured host; false = explicit NAT/port-publish opt-out. Threaded into the
driver, the AdminUI browser (same JSON) and the AdminUI form (a select that
keeps "unset" unset), Client.Shared ConnectionSettings.ValidateServerHostName
and the CLI --validate-host-name. A driver refusal names the opt-out.

#818: the NAT fixture's /app/pki is on the opc-plc-nat-pki volume (verified:
same thumbprint across --force-recreate), its PUBLIC cert is committed as
Docker/nat/opc-plc-nat-server.der, and NatPublishedEndpointBrowseTests run
every secure browse on a throwaway PKI (internal browser seam): refusal with
nothing trusted, positive with the cert trusted (unset/false host check), and
a BadCertificateHostNameInvalid refusal with the check on. The trusted cert is
OPCUA_NAT_SERVER_CERT or the committed one (skip on thumbprint mismatch);
OPCUA_NAT_SERVER_CERT_TRUSTED is retired. CI exports its throwaway NAT
container's public cert. ServerHostNameValidationTests pin the driver against
the plain opc-plc. MIN_EXECUTED not raised (needs a hosted run): +6 in
v2-integration (440 -> 446), documented in scripts/ci/README.md.
2026-11-11 01:33:00 -05:00
Joseph Doherty 8e8408a9ca fix(opcuaclient): keep the configured IPv6 zone index through the endpoint rewrite (#819)
.NET's Uri parses a zone ([fe80::1%eth0]) but drops it from Host, Authority,
AbsoluteUri and ToString(); only DnsSafeHost/IdnHost carry it. The shared
OpcUaEndpointUrlRewriter rebuilt the URL through UriBuilder, so the zone was
lost and link-local endpoints were unroutable. The SDK dials
new Uri(EndpointUrl).IdnHost (TcpByteTransport -> DnsEndPoint), which keeps
it, so splicing the zone back into the string is enough. Kept verbatim
(%eth0, %4, or RFC 6874 %25eth0) so the session dials exactly what
GetEndpoints reached. Applies to the driver, the AdminUI browser and the
Client CLI/UI (all share the rewriter).
2026-11-11 01:32:38 -05:00
Joseph Doherty d52a3b1c64 fix(client): Client.Shared EndpointSelector uses the shared OpcUaEndpointUrlRewriter (#812)
Client.Shared now project-references Driver.OpcUaClient.Contracts (Core.Abstractions
only, no NuGet/SDK; pinned by ContractsIsDependencyLightTests) and delegates the
host/port rewrite to OpcUaEndpointUrlRewriter, deleting its own copy.

The two copies differed; reconciled toward the client so its pinned behaviour is
unchanged (EndpointSelectorRewriteParityTests, written green against the old copy):
- no-op rewrite (same host case-insensitively + same port) now returns the advertised
  string verbatim in the shared rewriter too (it re-serialised: added a trailing slash
  and case-folded a case-only host difference);
- a real rewrite serialises via AbsoluteUri, not Uri.ToString(), which un-escaped the
  advertised path (/x%20y became /x y) in the driver + browser;
- unusable URLs: the rewriter still falls back to the configured URL (driver/browser);
  the client keeps its loud failure as call-site validation (null -> InvalidOperation,
  unparseable -> UriFormatException).
2026-11-10 22:46:51 -05:00
Joseph Doherty 378962eeb1 fix(opcuaclient-browser): keep configured host/port behind NAT (#806)
The AdminUI OPC UA browse picker connected to the EndpointUrl the server
advertised in GetEndpoints verbatim, so behind NAT / a container port
publish it dialled the server's private hostname + internal port and
failed DNS where the runtime driver (which rewrites per #676) connected.

- Move the rewrite to the shared OpcUaEndpointUrlRewriter (.Contracts,
  pure Uri logic, no SDK dependency) and the policy+mode selection to
  OpcUaEndpointSelection (.Session leaf). Driver and browser both select
  through it, so the browse connects exactly where the driver does.
- Policy/mode filter, server certificate and strict browse PKI
  (no auto-accept) are unchanged.
- Unit tests: rewrite (host/port differ, same, IPv6 both sides, path
  kept, port-less, scheme mismatch untouched), browser selection seam.
- Live NAT tests (Fixture=opc-plc-nat, OPCUA_NAT_ENDPOINT): browse via a
  published port with a premise check that the advertised host:port
  differs and does not resolve, nsu= round-trip, unreachable endpoint
  fails cleanly, SignAndEncrypt reaches the server and is refused
  BadCertificateUntrusted. Verified red without the rewrite.

Refs #806
2026-11-10 21:00:04 -05:00
Joseph Doherty 919009c5ef fix(ablegacy): stamp health from the injectable Clock; drop the redundant per-project TreatWarningsAsErrors (lmxopcua#768)
AbLegacyDriver stamped LastSuccessfulRead (init, read, write), the read's sample
timestamps and host-state change times from raw DateTime.UtcNow; only the backoff
path read the injectable Clock. All of them now read Clock(), so
NativePcccBridgeStatusHealthTests drives a manual clock (init at T0, read at T1)
and asserts LastSuccessfulRead == T1 exactly instead of spin-waiting for the wall
clock to pass the init stamp (#767). Without the driver change the 6 tests fail
(init stamp is wall-clock, not T0).

Directory.Build.props sets TreatWarningsAsErrors for every project since #766, so
the 75 per-csproj copies (64 src + 11 tests) are removed and the props comment
says it is now the only place. tools/mem-probe keeps its explicit opt-out.
Release build: 0 warnings, 0 errors; a planted CS0168 still fails the build in a
src project and in a test project that used to carry its own copy.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 13:40:07 -05:00
Joseph Doherty 826312befe docs: fill missing XML docs and strip tracking IDs from src comments
Clears CommentChecker findings in src/ (3,280 -> 209, the remainder being false
positives like PLC-5/IEEE-754/M0.0) by adding missing summaries/params/returns,
normalising inheritdoc usage, and removing Gitea/review tracking IDs while keeping
the rationale they annotated. Comment-only: comment-stripped sources are identical
to the parent commit.
2026-10-15 06:14:58 -04:00
Joseph Doherty fccffd0a0f feat(opcuaclient): #676 follow-ups — endpoint rewrite, stall wire test, fast definitive-loss recovery
- Endpoint rewrite: the driver now connects to the configured host AND port (scheme
  match, advertised path kept) instead of the server-advertised URL — fixes NAT/port-map
  upstreams and lets an in-test proxy carry the session (SDK SelectEndpoint rule).
- TcpStallProxy + OpcUaClientDriverStallWireTests: the in-place blip (#670) is now
  wire-tested on loopback — one Bad, frozen read stamp, same session, identical value
  republished Good, a post-recovery change arrives, no source-time regression after
  the SDK's late backlog flush.
- Defect found by that test, fixed: a change published right after a stall rode a
  Publish response the SDK timed out and never republished, leaving the node Good on
  the pre-change value indefinitely. New trailing reconcile read (Timeout +
  KeepAliveInterval after recovery) publishes any Good value newer than the last
  accepted one, through the replay guard's mark.
- IDriverConnectionLossSource (Core.Abstractions): opt-in definitive-loss signal.
  DriverInstanceActor attaches in PreStart / detaches in PostStop and turns a raise
  into a disconnect only while Connected. OpcUaClient raises once per session on
  keep-alive BadSessionIdInvalid/BadSessionClosed/BadSessionNotActivated/
  BadServerHalted (measured: the SDK never re-opens a halted channel) or a dropped
  subscription; ambiguous codes stay with the #527 watchdog.
- Replay guard: one Information summary per recovery when the window closes
  ("dropped N late notifications across M refs"), with a timer so quiet
  subscriptions log it too.
- ReconnectPeriod deleted (options, AdminUI form, docs, tests); stored configs that
  carry reconnectPeriod still parse in the factory, probe and browser.
- Docs: OpcUaClient.md, DriverLifecycle.md, driver-specs.md, CLAUDE.md.
2026-10-11 11:35:52 -04:00
Joseph Doherty 2a8f9af5e4 fix(opcuaclient): upstream session loss goes Bad and recovers (#670)
A bad keep-alive now degrades health (LastSuccessfulRead preserved) and,
once per outage, publishes BadNoCommunication (value retained) for every
subscribed ref plus a quality-only annotation on subscribed alarm
conditions. Good keep-alives and data/event notifications advance
LastSuccessfulRead, so an idle-but-alive subscription never looks dead
to the #527 watchdog. A keep-alive that recovers on the same session
re-reads the Bad refs and republishes them Good; a session that does not
come back is recovered by the watchdog's ShutdownAsync + InitializeAsync
+ re-subscribe.

Deletes the SessionReconnectHandler wiring (it retried forever in SDK
1.5.378, cloned subscriptions the driver never re-tracked and kept health
Healthy), OnReconnectComplete, TryRearmReconnect and the reconnect_*
counters (new keepalive_recovered). Teardown of a lost session skips
wire deletes and bounds CloseSession. SDK warnings reach the driver log.
Wire test reworked: restart => Bad, then watchdog-style reinit => Good.
2026-10-11 08:27:04 -04:00
Joseph Doherty dd05baedd6 refactor(opcuaclient): remove vestigial TargetNamespaceKind + UnsMappingTable (#648)
Nothing read the mapping table beyond the startup validator; v3 UNS projection is
explicit via UnsTagReference. Legacy keys in stored DriverConfig are ignored (pinned).
Reverts the docker-dev opc-plc seed workaround from fdee129f.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:14:37 -04:00
Joseph Doherty 1219b7b13e fix(opcuaclient): review fixes - drop driver-side OperationLimits chunking (SDK batches), diagnostics as OTel counter, safe discovery selection, options validation at load (#273 #275 #276 #277 #278)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 14:55:53 -04:00
Joseph Doherty ba62022e88 feat(opcuaclient): subscription tuning, OperationLimits chunking, diagnostics counters, revocation options, DiscoveryUrl (#273 #275 #276 #277 #278)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 14:40:20 -04:00
Joseph Doherty be5899bc7d fix(adminui): OpcUaClient editor reads the legacy PascalCase NodeId at the reader's precedence (#557 item 1)
`OpcUaClientTagDefinitionFactory.TryReadNodeId` still honours a legacy PascalCase
`NodeId` when the v3 camelCase `nodeId` is wholly absent, but
`OpcUaClientTagConfigModel` read only `nodeId` — so a legacy blob was SERVED by
the driver yet opened with an empty reference field and could not be saved
untouched. Authoring stricter than the reader, which #554 names as never
legitimate: the editor was blocking config the runtime honours.

Fixed with the #550 pattern (read both spellings, normalise on save), NOT by
retiring the spelling from the reader — that would break every legacy blob the
driver currently serves at the next deploy, a data-plane regression traded for
an editor asymmetry.

The precedence is PRESENCE-shadows, not first-non-blank. The reader's
`TryGetProperty("nodeId", out n) || TryGetProperty("NodeId", out n)`
short-circuits on the mere PRESENCE of the camelCase key and then checks
string-and-non-blank ONCE, so a blank / non-string / JSON-null `nodeId` beside a
valid legacy `NodeId` is a REJECTED blob, not a fallback. Copying MTConnect's
`FirstNonBlank` walk here would have made authoring WEAKER than the reader —
the same defect in mirror image.

- `NodeIdKeys` drives both halves, so the read and the drop cannot drift.
- `ToJson` writes `nodeId` and drops `NodeId`; the TagModal history-merge keys
  (`isHistorized` / `historianTagname`) are disjoint and untouched.
- `Validate`'s required-reference fast path is now precedence-aware by
  construction, so it agrees with the #554 parse consult across the whole
  rejection surface.
- The `TagConfigNonEnumParityTests` exemption for OpcUaClient is REMOVED — its
  anti-vacuity guard `Every_deliberately_stricter_entry_is_still_exactly_that`
  went red on the fix, which is this change's falsification control. The legacy
  shapes moved into the corpus, where both fleet theories now cover them.

Tests: a nine-row precedence theory driving the authoring verdict against the
READER's verdict per shape, on the original blob AND on the `ToJson()` output;
no-retype (legacy loads showing its reference, saves canonical, same node id
before and after); no-drift (output never carries `NodeId`). Each half was
reverted in isolation to confirm it reddens tests of its own: read-only-revert
=> 6 red incl. the fleet parity theory; drop-only-revert => 4 red.

Suites: AdminUI.Tests 1459/1459, ControlPlane.Tests 261/261,
Driver.OpcUaClient.Tests 143/143, Driver.OpcUaClient.Browser.Tests 10/10.
2026-08-10 03:01:41 -04:00
Joseph Doherty b4f8cb8de7 refactor(opcuaclient): move NamespaceMap to a .Session leaf so Contracts is dependency-light
G-7 wired OpcUaClientTagDefinitionFactory.Inspect into the deploy-time TagConfig
gate, which gave ControlPlane a ProjectReference to
Driver.OpcUaClient.Contracts — and with it, transitively, the whole OPC UA client
stack (5 OPCFoundation packages) into every host that loads the control plane.

NamespaceMap was the only reason Contracts carried
OPCFoundation.NetStandard.Opc.Ua.Client: its entire public surface is
ISession/NamespaceTable/NodeId-typed. It moves to a new leaf project,
ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient.Session, referenced by the runtime .Driver
and by .Browser. Contracts is left with Core.Abstractions and NOTHING else —
the same shape as Calculation.Contracts.

The namespace stays ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient, so no consumer's
`using` changed. The .Session -> .Contracts direction is deliberate: the blob
read NamespaceMap needs is OpcUaClientTagDefinitionFactory.TryReadNodeId, the
one authority it shares with the deploy gate, and that must stay in the
dependency-light half.

Why a new project rather than folding NamespaceMap into the runtime .Driver and
having .Browser reference it (the Driver.Mqtt.Browser #512-style deliberate
exception): the AdminUI project-references .Browser and NOT .Driver, so that
shape would pull the OpcUaClient driver runtime — plus Core,
Opc.Ua.Configuration and Secrets.Abstractions — into the AdminUI's build/deploy
graph. That is exactly the violation #512 spent two extractions removing from
Mqtt.Browser; re-introducing it to save one csproj is a bad trade.

Guard: ContractsIsDependencyLightTests (Driver.OpcUaClient.Tests) asserts the
Contracts manifest names no Opc.Ua* assembly, plus a counterpart asserting
.Session does. An ABSENCE assertion is sound on the manifest where a presence
one is not — the compiler elides an unused reference, but it MUST emit one the
moment Opc.Ua-typed code is added. Falsified by temporarily re-adding the
package plus an Opc.Ua.NodeId-typed member: red on Opc.Ua.Types, green again on
removal.

Evidence — `dotnet list ControlPlane package --include-transitive | grep -i opc`:
  before: OPCFoundation.NetStandard.Opc.Ua.{Client,Configuration,Core,
          Security.Certificates,Types} 1.5.378.106
  after:  none (and 0 Opc.Ua*.dll in ControlPlane's output directory)
2026-08-09 21:56:29 -04:00
Joseph Doherty 2947a2b9e2 feat(drivers): Contracts-side TagConfig Inspect for Sql, MTConnect, Calculation and OpcUaClient
Deferment-register G-7: these four were validated by the AdminUI's TagConfigValidator at
authoring but by nothing at deploy, so config arriving by CSV import or API met no gate at
all. The deploy gate dispatches to a driver's *TagDefinitionFactory.Inspect in its Contracts
assembly, and none of the four had one.

Rather than mirror the AdminUI models (a mirror of an accept/reject boundary drifts silently,
with the gate describing a shape the driver no longer reads), each Inspect is built on the
driver's own runtime parse:

- Sql wraps the existing SqlEquipmentTagParser, which already lived in Sql.Contracts. The
  P3-deferred Query model stays refused; Inspect surfaces the refusal rather than weakening it.
- MTConnect's blob reader MOVED out of MTConnectDriver (it was private, with a private DTO)
  into MTConnectTagDefinitionFactory; the driver now calls it. Behaviour unchanged.
- OpcUaClient's nodeId read MOVED off NamespaceMap into OpcUaClientTagDefinitionFactory;
  NamespaceMap now calls it. Behaviour unchanged.
- Calculation gains a Contracts assembly it never had. Only the JSON reading moved there
  (CalculationTagDefinitionFactory.TryReadTagConfig); building a CalculationTagDefinition
  still needs EquipmentScriptPaths from Commons and stays in the driver, so the split is at
  the blob boundary. The new project is deliberately reference-free — a calc blob is strings,
  a bool and an int, with no Core.Abstractions type in it.

Each Inspect runs the parse FIRST and returns empty on success, so "never stricter than the
runtime" is structural rather than a promise: a warning is only reachable for a blob the
driver would have refused and then skipped silently. Calculation additionally reports two
present-but-silently-discarded fields (a non-boolean changeTriggered reads as true; a
non-positive-integer timerIntervalMs is dropped), and deliberately does NOT warn about a
trigger-less tag or a sub-50ms timer — the editor refuses both, the runtime honours both, and
the deploy gate follows the runtime.
2026-08-09 21:14:32 -04:00
Joseph Doherty 9bb237b794 feat(secrets): G-2b resolve OpcUaClient secret: Password/UserCertificatePassword (Task 8)
Resolve secret:-prefixed Password + UserCertificatePassword through the shared
ISecretResolver, fail-closed on absent, retiring the cleartext-in-DB path. The
driver-registry factory is synchronous (Func<string,string,IDriver>), so resolution
is done lazily in the async session-open (InitializeAsync, before BuildUserIdentity)
rather than at deserialize — mirroring Task 7's Galaxy pattern and matching its
re-resolve-on-reconnect behavior. Both consumers (username Password and the
certificate-password LoadPkcs12 path via BuildCertificateIdentity) see the resolved
connect-scoped options; _options stays raw (secret: refs intact), no long-lived
plaintext field.

Scope corrections vs the plan (verified against v3): the probe is unauthenticated
GetEndpoints-only and never reads either credential, so it is NOT a resolution site
(comment added, no dead code); OpcUaClientDriverOptions was a sealed class, converted
to sealed record for the with-expression (no positional params → identical JSON; no
reference-equality/dict-key/ToString-log usages → no behavior/leak change).

ISecretResolver threaded via factory Register/CreateInstance + DriverFactoryBootstrap
(real resolver from DI); NullSecretResolver null-object backs test/parse paths only,
fail-closed on secret: refs. TDD: 4 helper tests RED→GREEN; 142 OpcUaClient tests pass.
2026-07-16 18:14:12 -04:00
Joseph Doherty ec01649905 v3(b1-opcuaclient): re-key OpcUaClient resolution to RawPath via RawTags
NamespaceMap now carries a RawPath -> upstream node id table built from the
deployed RawTagEntry list (reads each tag's TagConfig.nodeId, threads
WriteIdempotent). Under v3 the read/write/subscribe/history reference handed to
the driver is the tag's RawPath identity; the driver resolves it in two stages:
RawPath -> nodeId string (instance TryResolve) -> live NodeId re-bound against
the session (static TryResolve). Alarm ConditionId + event-history sourceName
stay on the direct session parse (they are upstream node ids, not RawPaths).

- Options: add IReadOnlyList<RawTagEntry> RawTags (Contracts now refs Core.Abstractions).
- Factory: RawTags binds straight into options (no separate DTO); EndpointUrl kept.
- Browser: unchanged (emits neutral BrowseNode DTOs, no TagConfig FullName key).
- Tests: 138 green; new RawPath resolution + factory-binding coverage; migrated
  the stale-session ReadRaw test to author a resolving RawTag.

Contracts + Driver + Browser build clean (0 warn). Wave C wires endpoint->DeviceConfig
and the deploy artifact that populates RawTags.
2026-07-15 20:11:44 -04:00
Joseph Doherty 9cad9ed0fc docs(xmldoc): fill missing XML docs + strip tracking-ID comments across src
v2-ci / build (push) Failing after 41s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped
Adds <summary>/<param>/<returns>/<inheritdoc> where missing and removes
project bookkeeping IDs (task/tracking refs) from shipped code comments,
so the docs read cleanly and CommentChecker is quiet except for known
false positives (PLC/protocol terms, event/IEqualityComparer inheritdoc).
Doc/comment-only; no logic changed; solution builds clean.
2026-07-07 12:38:39 -04:00
Joseph Doherty 9244e506c9 review(Driver.OpcUaClient.Contracts): first review; fix TryResolve nullability + [Range] guards
First review at 7286d320. -001 (Medium): TryResolve session param -> ISession? matching the
null guard + out-contract doc. -003: [Range] on MaxDiscoveredNodes/MaxBrowseDepth, drop dead
[Display]. -002 (NamespaceMap pulls full SDK into a DTO project) Open. Surfaced cross-module:
the OpcUaClient.Browser serializer lacks JsonStringEnumConverter (enum-as-int bug).
2026-06-19 12:22:53 -04:00
Joseph Doherty 7cd5cde315 refactor(opcuaclient): move NamespaceMap to Contracts, make public
Browser project (Phase 3) needs to share namespace-stable address encoding
with the runtime driver. Move keeps the same namespace, so existing usages
in OpcUaClientDriver compile unchanged.
2026-05-28 15:35:21 -04:00
Joseph Doherty f2f6eeb74e feat(drivers): expose ProbeTimeoutSeconds on every driver Options class
Adds a uniform [Range(1, 60)] ProbeTimeoutSeconds property to all 9
driver Options classes (Modbus 5s, AbCip 5s, AbLegacy 5s, S7 5s,
TwinCAT 10s, FOCAS 10s, OpcUaClient 15s, Galaxy 30s, Historian 15s).
Powers the AdminUI Test Connect button (Phase 7 of the plan).
2026-05-28 09:21:50 -04:00
Joseph Doherty 5f0e0482ed refactor(driver-opcuaclient): extract OpcUaClientDriverOptions to .Contracts
Move OpcUaClientDriverOptions and all companion enums (OpcUaTargetNamespaceKind,
OpcUaSecurityMode, OpcUaSecurityPolicy, OpcUaAuthType) to a new
Driver.OpcUaClient.Contracts sibling project. The options file had no
using directives — all types were defined in the same file — so no
NuGet mirror enum pattern was required.

Convert two doc-comment references:
  <see cref="OpcUaClientDriver.InitializeAsync"/> → <c>OpcUaClientDriver.InitializeAsync</c>
  <see cref="OpcUaClientDriver.ValidateNamespaceKind"/> → <c>OpcUaClientDriver.ValidateNamespaceKind</c>
per the approved decision — no compilable usings were present.

The runtime Driver.OpcUaClient project gains a ProjectReference to .Contracts;
the .slnx is updated accordingly.
2026-05-28 09:14:57 -04:00