feat(drivers): expose ProbeTimeoutSeconds on every driver Options class

Adds a uniform [Range(1, 60)] ProbeTimeoutSeconds property to all 9
driver Options classes (Modbus 5s, AbCip 5s, AbLegacy 5s, S7 5s,
TwinCAT 10s, FOCAS 10s, OpcUaClient 15s, Galaxy 30s, Historian 15s).
Powers the AdminUI Test Connect button (Phase 7 of the plan).
This commit is contained in:
Joseph Doherty
2026-05-28 09:21:50 -04:00
parent 8c0a32025d
commit f2f6eeb74e
9 changed files with 91 additions and 1 deletions
@@ -1,3 +1,5 @@
using System.ComponentModel.DataAnnotations;
namespace ZB.MOM.WW.OtOpcUa.Driver.AbCip;
/// <summary>
@@ -74,6 +76,14 @@ public sealed class AbCipDriverOptions
/// reads into one. The richer CIP Template Object path remains the long-term fix.
/// </summary>
public bool EnableDeclarationOnlyUdtGrouping { get; init; }
/// <summary>
/// Timeout for the AdminUI Test Connect probe, in seconds. The AdminUI clamps to a
/// 60s server-side maximum; this default is what the form pre-fills for new instances.
/// </summary>
[Display(Name = "Probe timeout (seconds)", Description = "Connection test timeout. Default 5s.", GroupName = "Diagnostics")]
[Range(1, 60)]
public int ProbeTimeoutSeconds { get; init; } = 5;
}
/// <summary>
@@ -1,3 +1,4 @@
using System.ComponentModel.DataAnnotations;
using ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.PlcFamilies;
namespace ZB.MOM.WW.OtOpcUa.Driver.AbLegacy;
@@ -21,6 +22,14 @@ public sealed class AbLegacyDriverOptions
/// <summary>Gets or sets the default timeout for read/write operations.</summary>
public TimeSpan Timeout { get; init; } = TimeSpan.FromSeconds(2);
/// <summary>
/// Timeout for the AdminUI Test Connect probe, in seconds. The AdminUI clamps to a
/// 60s server-side maximum; this default is what the form pre-fills for new instances.
/// </summary>
[Display(Name = "Probe timeout (seconds)", Description = "Connection test timeout. Default 5s.", GroupName = "Diagnostics")]
[Range(1, 60)]
public int ProbeTimeoutSeconds { get; init; } = 5;
}
public sealed record AbLegacyDeviceOptions(
@@ -1,3 +1,5 @@
using System.ComponentModel.DataAnnotations;
namespace ZB.MOM.WW.OtOpcUa.Driver.FOCAS;
/// <summary>
@@ -21,6 +23,14 @@ public sealed class FocasDriverOptions
public FocasHandleRecycleOptions HandleRecycle { get; init; } = new();
/// <summary>Gets the fixed tree options.</summary>
public FocasFixedTreeOptions FixedTree { get; init; } = new();
/// <summary>
/// Timeout for the AdminUI Test Connect probe, in seconds. The AdminUI clamps to a
/// 60s server-side maximum; this default is what the form pre-fills for new instances.
/// </summary>
[Display(Name = "Probe timeout (seconds)", Description = "Connection test timeout. Default 10s.", GroupName = "Diagnostics")]
[Range(1, 60)]
public int ProbeTimeoutSeconds { get; init; } = 10;
}
/// <summary>
@@ -1,3 +1,5 @@
using System.ComponentModel.DataAnnotations;
namespace ZB.MOM.WW.OtOpcUa.Driver.Galaxy.Config;
/// <summary>
@@ -15,7 +17,16 @@ public sealed record GalaxyDriverOptions(
GalaxyGatewayOptions Gateway,
GalaxyMxAccessOptions MxAccess,
GalaxyRepositoryOptions Repository,
GalaxyReconnectOptions Reconnect);
GalaxyReconnectOptions Reconnect)
{
/// <summary>
/// Timeout for the AdminUI Test Connect probe, in seconds. The AdminUI clamps to a
/// 60s server-side maximum; this default is what the form pre-fills for new instances.
/// </summary>
[Display(Name = "Probe timeout (seconds)", Description = "Connection test timeout. Default 30s.", GroupName = "Diagnostics")]
[Range(1, 60)]
public int ProbeTimeoutSeconds { get; init; } = 30;
}
/// <summary>
/// Connection details for the MxAccess gateway. <see cref="ApiKeySecretRef"/> is
@@ -1,3 +1,5 @@
using System.ComponentModel.DataAnnotations;
namespace ZB.MOM.WW.OtOpcUa.Driver.Historian.Wonderware.Client;
/// <summary>
@@ -30,4 +32,12 @@ public sealed record WonderwareHistorianClientOptions(
/// <summary>Gets the effective call timeout, using the default if not explicitly set.</summary>
public TimeSpan EffectiveCallTimeout => CallTimeout ?? TimeSpan.FromSeconds(30);
/// <summary>
/// Timeout for the AdminUI Test Connect probe, in seconds. The AdminUI clamps to a
/// 60s server-side maximum; this default is what the form pre-fills for new instances.
/// </summary>
[Display(Name = "Probe timeout (seconds)", Description = "Connection test timeout. Default 15s.", GroupName = "Diagnostics")]
[Range(1, 60)]
public int ProbeTimeoutSeconds { get; init; } = 15;
}
@@ -1,3 +1,5 @@
using System.ComponentModel.DataAnnotations;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus;
/// <summary>
@@ -174,6 +176,14 @@ public sealed class ModbusDriverOptions
/// attempt; <see cref="ModbusReconnectOptions.MaxDelay"/> caps the geometric growth.
/// </summary>
public ModbusReconnectOptions Reconnect { get; init; } = new();
/// <summary>
/// Timeout for the AdminUI Test Connect probe, in seconds. The AdminUI clamps to a
/// 60s server-side maximum; this default is what the form pre-fills for new instances.
/// </summary>
[Display(Name = "Probe timeout (seconds)", Description = "Connection test timeout. Default 5s.", GroupName = "Diagnostics")]
[Range(1, 60)]
public int ProbeTimeoutSeconds { get; init; } = 5;
}
/// <summary>OS-level TCP keep-alive knobs. Set <see cref="Enabled"/>=false to skip entirely.</summary>
@@ -1,3 +1,5 @@
using System.ComponentModel.DataAnnotations;
namespace ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient;
/// <summary>
@@ -164,6 +166,14 @@ public sealed class OpcUaClientDriverOptions
/// </summary>
public IReadOnlyDictionary<string, string> UnsMappingTable { get; init; }
= new Dictionary<string, string>();
/// <summary>
/// Timeout for the AdminUI Test Connect probe, in seconds. The AdminUI clamps to a
/// 60s server-side maximum; this default is what the form pre-fills for new instances.
/// </summary>
[Display(Name = "Probe timeout (seconds)", Description = "Connection test timeout. Default 15s.", GroupName = "Diagnostics")]
[Range(1, 60)]
public int ProbeTimeoutSeconds { get; init; } = 15;
}
/// <summary>
@@ -1,3 +1,5 @@
using System.ComponentModel.DataAnnotations;
namespace ZB.MOM.WW.OtOpcUa.Driver.S7;
/// <summary>
@@ -61,6 +63,14 @@ public sealed class S7DriverOptions
/// Running ↔ Stopped transitions.
/// </summary>
public S7ProbeOptions Probe { get; init; } = new();
/// <summary>
/// Timeout for the AdminUI Test Connect probe, in seconds. The AdminUI clamps to a
/// 60s server-side maximum; this default is what the form pre-fills for new instances.
/// </summary>
[Display(Name = "Probe timeout (seconds)", Description = "Connection test timeout. Default 5s.", GroupName = "Diagnostics")]
[Range(1, 60)]
public int ProbeTimeoutSeconds { get; init; } = 5;
}
public sealed class S7ProbeOptions
@@ -1,3 +1,5 @@
using System.ComponentModel.DataAnnotations;
namespace ZB.MOM.WW.OtOpcUa.Driver.TwinCAT;
/// <summary>
@@ -46,6 +48,14 @@ public sealed class TwinCATDriverOptions
/// section 6 — was previously hard-coded to 0 (Driver.TwinCAT-014).
/// </summary>
public int NotificationMaxDelayMs { get; init; }
/// <summary>
/// Timeout for the AdminUI Test Connect probe, in seconds. The AdminUI clamps to a
/// 60s server-side maximum; this default is what the form pre-fills for new instances.
/// </summary>
[Display(Name = "Probe timeout (seconds)", Description = "Connection test timeout. Default 10s.", GroupName = "Diagnostics")]
[Range(1, 60)]
public int ProbeTimeoutSeconds { get; init; } = 10;
}