Since #516 a DriverConfig change is stop + respawn, so DriverSpawnPlan.ToApplyDelta
was always empty and the in-place path had no producer. #663 and #664 were both
latent bugs in it. This deletes it:
- host: ApplyChildDelta, _pendingDelta, HandleApplyResult and HandleDeltaApplied
- plan: DriverSpawnPlan.ToApplyDelta
- actor: the ApplyDelta, ApplyResult and DeltaApplied messages, the Connected
reinit handler and the mid-connect AdoptConfigDuringInit
- tests: the actor tests that drove the seam
IDriver.ReinitializeAsync and each driver's implementation and unit tests stay.
Comments and docs that cited AdoptConfigDuringInit as the reason a driver must
release prior state at init now cite the IDriver contract and overlapping
retries, which still apply.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
- ReadBucketAsync: the once-per-device "sum-read chunk failed" Warning fires only after a successful
connect; a connect/backoff failure is the connect path's to report. TwinCATSumChunkWarningTests pins
it (no warning across connect failures, exactly one across two later failing sum polls; red without
the guard) plus a source guard that ReadGroupAsync builds its SumRead only via CreateSumRead.
- Docs: diagnostics live-gated via the driver harness (/hosts not exercised); TC2 costs 8 reads on the
first tick and after each reconnect, then <= 4; read counts attributed to the unit tests.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
Read-only live gate on Elma presses Z35474 (TC3 3.1.4024) and Z34834 (TC2 2.11):
- Sum-read: every chunk came back BadCommunicationError. Beckhoff's
SumRead(IList<IgIoSumReadEntity>) ctor casts to IList<SumDataEntity>, which
throws InvalidCastException for a List<> (only an array survives via
covariance). The fake-client tests never built a real SumRead. New
AdsTwinCATClient.CreateSumRead passes an array; TwinCATSumReadConstructionTests
pins it (red on the List form) plus a falsifiability control on the library.
After the fix: 59 tags, status identical everywhere, values identical on every
non-moving tag, ~0.35-0.66 s vs ~2.7 s per poll; TC2 CE 2.11 answers sum reads.
- An unexpected sum chunk failure now logs one Warning per device (it was
invisible: the health message was overwritten by the next good read).
- Diagnostics: TC2 has no TwinCAT_SystemInfoVarList; fall back to .SYSTEMINFO /
.SYSTEMTASKINFOARR[1] once the TC3 name answers not-found (live: all six keys).
- #612 browse: Flat verified on TC3 (10,770 leaves; VirtualTree 1,459 strict
subset) — comment and docs updated, no load-mode option needed.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
Strict width+kind eligibility for sum-batched scalars (others read singly); latch only on ADS
1793/1794, split 1792/1797/1798 without latching; 32 KiB per-command budget and 500-item ceiling;
short sum response handled per item. Diagnostics: opt-in diagnosticsEnabled (default off), reuse the
probe's ReadState, sample after the host-state transition, JitterMs renamed HeadroomMs, compact
per-device line so many devices fit the 16-entry cap, unavailable-symbol latch cleared on reconnect.
AdminUI: min/max on sum-read max, diagnostics checkbox. Pure planner extracted and unit-tested.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
Sum-read (#310): batches a poll's reads per device into sum commands capped at sumReadMaxItems,
per-item ADS errors mapped per tag, falls back to individual reads when the target refuses the
command. Diagnostics (#314): ADS state, app name, online-change count, task cycle/exec/jitter via
IDriverDiagnostics. Re-implemented against the current raw-byte read path (stranded auto/driver-gaps
commits predate it). Sum-write not ported. Unit tests only; live gate pending a route.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
FOCAS, AbLegacy, AbCip, TwinCAT, S7 and OpcUaClient orphaned the previous
probe/recycle/fixed-tree loops and clients when re-initialised on a live driver.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
Removes the 'use UseNativeNotifications=false for arrays' workaround and
documents the raw-bytes array model shared by poll and notification: element
checks, STRING arrays, multi-dim flattening, 0-based publication, leading
sub-range for a shorter arrayLength, refusals (struct/UDT arrays, too long,
scalar over array), the 128 KiB native cap (BadOutOfRange), the bit-path fix,
and the 2026-10-07 read-only live gate on Z33856 / Z33733.
Live on Z33856 a UInt tag over .ARRFAULTCODE (ARRAY [0..12] OF UINT) made the
Beckhoff read throw - BadCommunicationError and a Degraded driver - while the
native path reported BadTypeMismatch. CheckRead now refuses a scalar declared
over an array (by category, so an alias of an array type is caught), pointing
at the array-tag / element-path alternatives.
A native notification for MAIN.Flags.3 / .ADSSTATE_RUN.0 was registered on the
literal WORD.N path, which ADS has no symbol for: live on the TC 2.11 Elma
cleaner Z33856 it failed with DeviceSymbolNotFound, and that registration
error tore down the whole subscribe call. The read path already reads the
parent word; the notification now does the same - it registers the parent as
raw bytes at its resolved width and reads the bit (TwinCATBitAccess), refusing
a bit outside the parent or a non-integer parent with BadTypeMismatch.
An array tag subscribed natively used to register only its declared scalar
(publishing element 0 at Good) and was then refused wholesale with
BadTypeMismatch. The driver now hands the authored ArrayLength to the client,
which registers the whole array as raw bytes and decodes every notification.
- TwinCATTypeGuard.CheckArray plans the layout from the RESOLVED array type:
element checked like a scalar notification (width / float kind / string
kind); STRING(n)/WSTRING(n) elements stride n+1 / 2(n+1); multi-dim arrays
flattened in PLC memory order; an authored ArrayLength shorter than the PLC
array reads the leading sub-range, a longer one is refused; struct / pointer
/ nested-array elements, non-array symbols and VAR_IN_OUT refs are refused.
- CheckNotificationSize caps a native array at 128 KiB (largest registration
proven on a live TC 2.11 target); above it the tag is refused BadOutOfRange.
- TwinCATArrayCodec decodes the bytes into the element-typed CLR array.
- The poll read uses the same plan + codec instead of the Beckhoff typed array
read, which failed live for most real arrays (exact CLR element type, rank-N
for multi-dim, member arrays sliced by the under-reported TC2 symbol size).
- TwinCATNotificationRefusedException carries the refusal's status; the type
mismatch derives from it and the driver isolates either per tag.
Found by the read-only live gate against the TwinCAT 2.11 Elma cleaners
Z33856 / Z33733:
- The Beckhoff library reports a TC2 dotted MEMBER symbol's ByteSize as if the
PLC's byte count were a bit count (STRING(80) -> 11, INT -> 1, UDINT -> 1)
while DataType.ByteSize is right (81/2/4, raw SYM_INFOBYNAMEEX says 81). The
previous commit's typeof(byte[]) read sliced by the symbol size, so
.OPC_MACHINEDATA.PROCESSSTATUS read "ready for o" at Good; the notification
width check would also have refused every numeric member. The shape now takes
the resolved type's size, and string reads go by index group/offset (or a
fresh handle for 0xF005) at that width.
- P_INITINPUT_ACTION.SLOTID is "STRING(20) (VAR_IN_OUT)" - a 4-byte reference -
but resolves to a plain STRING(20); a String tag read 21 bytes at the pointer
as text at Good. The symbol's own VAR_IN_OUT marker now classifies it
NonScalar -> BadTypeMismatch.
Port of the ignitionoee TwinCAT string + type-reconciliation fixes onto the
Beckhoff-library client:
- STRING/WSTRING subscriptions never worked: AddDeviceNotificationExAsync was
called with typeof(string) and no length, and the Beckhoff any-type
marshaller throws ArgumentNullException for a string without one, so one
string tag tore down its whole subscribe call. A string now registers the
PLC's own byte width as raw bytes (0.19.2: STRING(n) of any n).
- Strings are read as raw bytes and decoded by TwinCATStringCodec. The
Beckhoff marshaller already cut a read at the first NUL (0.19.3 / TwinCAT-007
were not defects on the read path); the codec keeps that rule for both STRING
and WSTRING and extends it to the new notification path. A STRING now decodes
as Windows-1252 (TwinCAT-010) - or UTF-8 when the target reports UTF-8
strings - instead of the host culture's ANSI code page the Beckhoff
marshaller falls back to (1250 on a Polish host, 1251 Cyrillic, ...).
- TwinCATTypeGuard (TwinCAT-002/-008): a read refuses a numeric tag over a PLC
string (and vice versa / STRING vs WSTRING / string over a container) with
BadTypeMismatch instead of handing back a string object at Good; a
notification - raw bytes decoded as the DECLARED type - additionally refuses
width and float/integer mismatches (DINT over REAL reinterpreted the bits).
- A refused notification is isolated: that tag publishes BadTypeMismatch with
one WARN, keeps a dead intent for the probe-tick retry, and the rest of the
subscription registers.
A TC2 PLC reports top-level integer globals as INT16/UINT16 (354 symbols on
the Elma cleaner Z33856) and the Beckhoff type system keeps that spelling as
a built-in primitive, so MapSymbolTypeName returned null and discovery dropped
them silently. INT16/UINT16/INT32/UINT32/UINT8/FLOAT/DOUBLE now map like their
IEC twins; padded member names ("REAL ") are trimmed; a parenthesised
non-string form ("INT (VAR_IN_OUT)", a reference) stays unsupported.
A TC2 global is named with ONE leading dot (.OPC_HEARTBEAT) and the PLC
requires it (SYM_HNDBYNAME answers 0x710 without it). TryParse rejected the
dot, so the driver fell back to the raw string and lost bit-index parsing:
.X.WORD.3 went to ADS verbatim instead of reading .X.WORD and extracting bit 3.
The dot now stays on the root segment and round-trips through ToAdsSymbolName;
.., ., .[1] and .9x stay invalid.
Found on the docker-dev live gate, not in tests. Two drivers that faulted
during initialise (rtu-gate, opcua1) each rendered "0 tags" on /hosts against
two authored tags apiece, because a ledger that had never committed returned
SkippedTagReport.Empty.
A zero report is a positive claim -- "this driver skipped nothing" -- and
making it on behalf of a driver that never got as far as looking is exactly
the quiet inaccuracy #541 exists to remove. GetSkippedTags() and
SkippedTagLedger.Snapshot() now return null until the first committed build,
so the column renders the same em-dash it already used for a driver that
cannot report at all. Both are 'no answer'; neither is 'nothing skipped'.
Knock-on: a FOCAS driver whose only init threw now reports null rather than a
zero report, which is strictly more honest than the assertion the test
originally made.
A driver builds its RawPath -> definition table at init and tolerates a
per-tag miss: an unmappable TagConfig, an unparseable address, a
capability-matrix rejection. That tolerance is right -- one bad tag must not
take down the other few thousand. What was missing is any statement of the
fact afterwards. A skip is not an error and happens before any read, so the
driver stays Healthy, errors/5 min stays 0, Last error stays empty, and Last
read advances live off the tags that did map. On the wonder Makino in #540
that reading held while focas-z-34184 ignored 20 of its 22 tags.
New optional capability ISkippedTagReporter, backed by a shared
SkippedTagLedger so the reset/commit/cap rules are one implementation rather
than one per driver. The report -- authored count, exact skipped count, and a
capped sample of RawPath + reason -- rides DriverHealthChanged to a new Tags
column on /hosts, over the Phase 5 telemetry stream. No table: a driver-only
node has no ConfigDb to write to, the lesson from #521.
The issue named eight drivers. It is twelve -- every driver in
DriverTypeNames.All has an authored-tag skip path. Calculation (no scriptId),
MTConnect (no readable DataItem id), Galaxy (no attributeRef) and OpcUaClient
(no nodeId) were unlisted, and OpcUaClient's was the quietest of the twelve:
NamespaceMap drops such an entry with a bare `continue` and not even a log
line. SkippedTagReporterFleetTests pins the invariant reflectively over every
IDriver in src/Drivers/, so a thirteenth cannot re-introduce the silence.
Sql drops a tag at TWO points and its report is the union of both: a blob
that does not map, AND an identifier the 8.1 catalog gate rejects against the
live catalog. The second is what schema drift produces -- a renamed column, a
dropped view -- months after a deployment sealed green, and reporting only
the first would have that driver claim "0 skipped" while polling half its
tags, which is worse than reporting nothing because the column would then be
actively reassuring.
Deliberately additive to driver state, never a change of it. Latching
non-Healthy for a config problem would satisfy both halves of the #527
comms-loss conjunction -- 90 s without a successful read AND non-Healthy --
and a driver whose tags were ALL skipped has no successful reads by
construction, so it would reconnect-loop forever against a healthy device.
Three details that are load-bearing rather than incidental:
- The skip digest is part of the publish fingerprint. A skipped tag leaves
every other fingerprint component identical to a clean driver's, so without
it PublishHealthSnapshot's dedup swallows exactly the publish carrying the
signal -- the trap that already bit the rediscovery and host-status
channels. The digest covers the sample, not just the counts: a redeploy
that fixes one tag and breaks another leaves both counts unchanged.
- The count is exact; only the sample is capped, and the tooltip says so when
it is showing fewer than it counted. A truncated list that looked complete
would have an operator fix twenty tags and believe the job done.
- The ledger stages and commits, so an init that throws part-way leaves the
previous report standing. A partial snapshot would read as "we now skip
fewer tags", the opposite of the truth.
The proto field needs no companion presence flag, unlike host_statuses: a
singular message field carries real presence in proto3, and a has_ flag would
collide with protoc's generated HasSkippedTags.
Verified red-first three ways: dropping SkippedTagDigest from the fingerprint
fails the two dedup tests, removing the seam from one driver fails the fleet
guard, and dropping the catalog-gate leg fails the Sql union test. Full
solution builds with zero new warnings against 4e22f024.
A browse-committed AB CIP / TwinCAT / FOCAS tag bound with its model's DEFAULT
data type, not the one the device reported. A browsed REAL committed as
`{"tagPath":"Pump_1_Speed","dataType":"DInt"}` — and those three drivers decode
the wire bytes by that field, not by the raw row's OPC UA DataType — so the tag
read four bytes of a float through an integer decoder and published a plausible
wrong number with no error raised anywhere. FOCAS was missed when #536 was filed.
The type is CARRIED, not derived. Reverse-mapping the leaf's driver-agnostic
DriverDataType looks like the smaller fix and is wrong: SInt/Int/DInt/USInt/UInt
all collapse into Int32 on the way out of the driver, so that version would bind
a 16-bit INT as a 32-bit DINT while appearing to fix the REAL. Drivers now state
their own type name on DriverAttributeInfo.NativeDataType, which reaches the
picker as AttributeInfo.AddressFields["dataType"] and the commit mapper from
there. A leaf that states nothing keeps the model default — the pre-#536
behaviour, kept deliberately as the fallback rather than a guess.
Numeric strings are refused before parsing: Enum.TryParse accepts "9" for any
enum and Enum.IsDefined then confirms it, so an unguarded parse would bind a tag
to a type nobody named. A test caught this in the first version of the guard.
--- and the other half, which the fixture was hiding ---
Test Connect on a device with NO authored tags — every AB CIP device at the
moment an operator first presses the button — reported "CIP handshake failed"
against a healthy controller. That was written down as a fixture limitation
("ab_server doesn't implement @raw_cpu_type"). Both halves of that were wrong:
* @raw_cpu_type is not a libplctag special tag at all (only @raw, @tags and
@udt/ are), so it goes out as an ordinary symbolic name that no controller
defines, and the controller's "tag does not exist" IS the successful answer.
* ab_server answered an unresolvable tag path with CIP 0x03 where a Logix
controller answers 0x04 — ErrorBadParam vs ErrorNotFound, which the probe
classifies oppositely. Fixed in vendored patch 0002.
* With the fixture then telling the truth, the real defect surfaced:
AbCipDriverProbe.IsReachableException matched the native C status spellings
("STATUS_NOT_FOUND"), but libplctag.NET throws with the MANAGED enum name
("ErrorNotFound"). Those substrings can never match, so the reachable
classification could not fire on the exception path — which is the path every
no-authored-tags probe takes. This was failing on real hardware too, not just
against the sim. It now recovers the Status and defers to IsReachableStatus,
so there is one classification rather than two that can drift.
Rejected: switching the fallback to @tags. libplctag builds a tag-listing tag
with NO network I/O, so it reports OK against any TCP listener — measured green
against a Mosquitto broker.
Verification: full solution suite green. Falsification runs confirm exactly the
intended tests go red — 9 for the type carry, 3 (the reachable statuses only) for
the probe classification. Live on docker-dev: browse-committed TestString/
Motor_Run/TestSINT now store String/Bool/SInt, alongside last session's
Pump_1_Speed still holding the wrong DInt. TestSINT is the falsifier — its row
DataType is Int32, identical to TestDINT's, so no reverse map could have produced
"SInt".
Known consequence: pre-existing browse-committed tags keep their wrong dataType;
the fix applies to new commits only.
Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
Both `IDriver` members had no production call site. Their only consumer was
`MemoryTracking`, deleted with the driver-tier recycle machinery in #522, and
`GetMemoryFootprint`'s doc-comment claimed "polled every 30s by Core" — which
had not been true since v3, even before #522 removed the poller.
Owner decision on #525 was (a) delete rather than (b) build the process-wide
watchdog that would consume them. The driver-side implementations are in git
history and were mostly reusable; what was always missing is the trigger, and a
member nobody calls is how the misleading doc-comment survived this long.
Removed from `IDriver`, all 12 driver implementations, and every test stub —
plus the support code that existed only to feed them, which is the part a
member-only deletion would have left behind as dead weight:
- MTConnect's three per-entry byte-weight constants, its cached
`ProbeModelDataItemCount`, and `CountDataItems` — a full device-tree walk run
on every cache fill to populate a number with no remaining reader.
- OpcUaClient's `_discoveredNodeCount` field and the discovery-pass write to it.
- MQTT's `ApproxBytesPerAuthoredTag`.
Two behavioural notes, neither a change in what the software does:
- `AbCipTemplateCache` now has no production reset path. Its only caller was
AB CIP's flush, which itself had no caller — so nothing changes except how
visible the fact is. Recorded on the type, along with the correction that its
comment's claim about a device `ReinitializeAsync` also flushing it was never
true. A UDT redefined on a live controller keeps its stale shape until the
driver instance is rebuilt.
- MTConnect's `/probe` cache is still dropped, by `InvalidateProbeModel()` on an
Agent restart. That is now `internal` rather than `private` so the tests which
used the flush purely to empty the cache drive the real path instead — they
now cover a case that actually occurs in production. Several unrelated doc
comments cited `FlushOptionalCachesAsync` as the canonical CAS example and are
repointed to it.
Tests: the ones that existed only to assert on the removed members are deleted
(3 OpcUaClient, 3 Galaxy, 2 MQTT, 1 MTConnect, 1 AbCip). Worth noting one was
vacuous — `FlushOptionalCachesAsync_resets_footprint_counter` asserted a
footprint of 0 before the flush and 0 after with no discovery in between, so it
would have passed against a flush that did nothing at all.
Full suite green except 7 failures verified identical on master before and
after (4 AbLegacy integration with the compose profile down, 3
Host.IntegrationTests), checked by name rather than assumed.
Docs corrected where they described this as live: `DriverLifecycle.md` (which
carried the #525 placeholder), `drivers/AbCip.md`, `drivers/AbLegacy.md`, and
`v2/driver-stability.md` — whose "polls this every 30 s" + per-driver
`DriverConfig` memory budget were never built as written and are now banner-ed
as design intent rather than description.
Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
Removes the tag-set drift detector shipped in e77c8a35. The design was sound
-- the tautology drivers were correctly gated out, and the structurally
undetectable "vanished" direction was declared rather than faked -- but none of
that is the objection. The feature browsed real plant equipment on a recurring
timer, at a frequency no operator could configure (the interval was a
constructor parameter with no appsettings key), and that outbound traffic was
never once observed against a real PLC, CNC or MTConnect Agent.
Removed: TagSetDrift/TagSetDriftDetector; DriverInstanceActor's drift timer,
tick message, Props/ctor parameter, gate, handler and leaf-collector;
ITagDiscovery.AuthoredDiscoveryRefs + .DiscoveryStreamIncludesAuthoredTags and
their four implementations; 14 tests.
Kept: ITagDiscovery.SupportsOnlineDiscovery (it predates this and drives the
universal browse picker), and the whole IRediscoverable consumption from
09a401b8 -- the driver tells us, we do not poll.
CONSEQUENCE, deliberately accepted: AbCip and FOCAS browse a live backend but
implement no IRediscoverable, so they now have NO tag-change signal at all -- a
PLC re-download is invisible until someone re-browses by hand. Recorded in
CLAUDE.md so the next reader does not have to rediscover it, along with the
shape to reach for if that coverage is wanted back (event-driven, or triggered
by a reconnect/deploy, not a wall-clock timer).
Runtime.Tests 476 pass / 13 skipped (skip set unchanged); FOCAS 275, TwinCAT
192, MTConnect 491, AbCip 342, Core.Abstractions 266 all green.
Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
The second thing #516/§8.2 deliberately did not build. The original objection
stands — Modbus, S7, MQTT, AbLegacy and Sql echo authored config from
DiscoverAsync, so diffing discovered against authored is a tautology for them
— but it is now ENCODED rather than used as a reason not to build.
The discriminator already existed: ITagDiscovery.SupportsOnlineDiscovery is
documented as "enumerates the tag set from the live backend rather than
replaying pre-declared/authored tags", and it separates the fleet cleanly —
FOCAS, TwinCAT, MTConnect and AbCip true; the five config-echo drivers
explicitly false. The check runs only for a driver that is
SupportsOnlineDiscovery AND reports the new AuthoredDiscoveryRefs. That is
nullable rather than empty-by-default on purpose: an empty collection
legitimately means "nothing authored, everything discovered is new", so
conflating the two would report total drift for a driver that never opted in.
Where the value is: AbCip and FOCAS browse a live backend but implement no
IRediscoverable, so before this they had no change signal at all. A periodic
compare is the only way to notice a PLC re-download.
A finding that changed the design: FOCAS, TwinCAT and AbCip all re-emit their
authored tags into the same DiscoverAsync stream as device-derived ones, so
the browse picker can show an operator their existing tags. Discovered is
therefore always a superset of authored, and a VANISHED tag can never appear
missing — one whole direction is structurally undetectable for three of the
four. Shipping a Vanished list that is permanently empty for them would have
been the half-inert seam this whole exercise removes. So the driver declares
DiscoveryStreamIncludesAuthoredTags, the detector does not compute the
undetectable half, and the operator message says "missing-tag detection
unavailable for this driver" rather than letting the absence of a missing-tag
clause read as reassurance. MTConnect is the only driver where both directions
work — its stream is purely probe-model-derived.
Behaviour: a failed browse is not drift (an unreachable device would otherwise
report every authored tag as vanished); a truncated capture is skipped for the
same reason; an unchanged drift is reported once rather than re-stamping its
timestamp; drift that resolves clears the prompt. Interval defaults to 5
minutes — it browses a real device, and a tag set changing is an engineering
event, not a runtime one. It reuses the Stage-2 surfacing, raising the same
/hosts re-browse prompt, and never rebuilds the served address space.
Comparison logic is a pure, separately-tested type rather than actor-inline.
14 new tests. The gate was verified load-bearing by deleting the
SupportsOnlineDiscovery half: the tautology-driver test goes red, and it
asserts discovery was never invoked rather than merely "no prompt raised",
which would have passed for the wrong reason if the timer never fired.
Full suite green except the same three pre-existing fixture-gated integration
suites, identical counts.
Every value verified against Opc.Ua.StatusCodes in the pinned SDK (1.5.378.106) by
reflection, not by copying siblings. All are client-visible: OPC UA clients branch on
status.
The three named in #497:
- Historian.Gateway SampleMapper "BadNoData" 0x800E0000 -> 0x809B0000
(0x800E0000 is BadServerHalted)
- Galaxy "BadTimeout" 0x800B0000 -> 0x800A0000
(0x800B0000 is BadServiceUnsupported)
- TwinCAT BadTypeMismatch 0x80730000 -> 0x80740000
(0x80730000 is BadWriteNotSupported)
BadTypeMismatch was wrong in three MORE drivers the issue did not name — FOCAS,
AbLegacy and AbCip carried the same 0x80730000. Every call site is a
FormatException/InvalidCastException conversion failure, so the name was right and
the value was wrong in all four.
Adding the reflection guard then surfaced nine further defects offline tests had
never checked:
- Galaxy GoodLocalOverride 0x00D80000 -> 0x00960000 (not a UA code at all)
- Galaxy UncertainLastUsableValue 0x40A40000 -> 0x40900000
- Galaxy UncertainSensorNotAccurate 0x408D0000 -> 0x40930000
- Galaxy UncertainEngineeringUnitsExceeded 0x408E0000 -> 0x40940000
- Galaxy UncertainSubNormal 0x408F0000 -> 0x40950000
- TwinCAT BadOutOfService 0x80BE0000 -> 0x808D0000 (was BadProtocolVersionUnsupported)
- TwinCAT BadInvalidState 0x80350000 -> 0x80AF0000 (was BadAttributeIdInvalid)
- AbCip/AbLegacy GoodMoreData 0x00A70000 -> 0x00A60000 (was GoodCommunicationEvent)
- Historian.Gateway GatewayQualityMapper Good_LocalOverride 0x00D80000 -> 0x00960000
Galaxy's whole Uncertain block read as though the OPC DA quality byte could be
shifted into the UA substatus position; it cannot — the substatuses are an unrelated
enumeration. GatewayQualityMapper already held the correct table, which is what the
Galaxy values are now reconciled against.
Guard: StatusCodeParityTests (Core.Abstractions.Tests, which already project-
references every driver) reflects over every `const uint` in the deployed
ZB.MOM.WW.OtOpcUa.Driver.*.dll whose name reads as a status code, and asserts it
equals Opc.Ua.StatusCodes.<name>. Discovery is by convention, so a new driver
assembly referenced by that project is covered with no edit here. It went red on all
nine defects above before the fixes and now checks 109 constants green.
Because reflection can only see a NAMED constant, two inline literals were hoisted so
the guard can reach them: Galaxy's BadTimeout/Bad into StatusCodeMap, and
GatewayQualityMapper's 15-entry table into a new HistorianStatusCodes. An inline
`0x800B0000u, // BadTimeout` at a call site is exactly how the Galaxy defect survived.
The drivers stay SDK-free by design; only the test project references Opc.Ua.Core,
as the oracle.
Also corrected: tests that pinned the wrong values (Galaxy StatusCodeMapTests,
SampleMapperTests, GatewayQualityMapperTests — all written from the same bad source),
a mislabelled comment in DriverInstanceActorTests, and stale constants in two design
docs, one of them the unexecuted MTConnect driver design that would have propagated
BadNoData's wrong value into a new driver.
The CLI's SnapshotFormatter value->name table was checked against the SDK and is
correct; no change needed.
Task 3/4/5: SupportsOnlineDiscovery => true on AbCipDriver, TwinCATDriver, FocasDriver
(their device enumeration is real, config-gated on EnableControllerBrowse / FixedTree.Enabled
which PatchForBrowse guarantees at open). One gate fact per driver test project.
- CapabilityInvoker: 3 methods that implement IDriverCapabilityInvoker now use
<inheritdoc /> instead of duplicating the interface docs (MissingInheritDoc).
- TwinCAT NativeRegistration ctor: added the 8 missing <param> tags (MissingParam).
- Stripped the arch-review bookkeeping IDs STAB-1 (IS7Plc, S7Driver) + STAB-2
(TwinCATDriver x4) from comments, keeping the descriptive text.
Left the other 86 flagged items untouched — they are checker false positives on
legitimate technical content: interface-implemented events / IEqualityComparer /
IDisposable members whose <inheritdoc/> IS correct (10 InheritDocMisused), and domain
terms the heuristic misreads as tracking IDs (IEEE-754, S7-1200/300/400/1500, PLC-5,
D2-260, S7/Melsec memory addresses, OPC UA Part 9, phase-N design-doc filename refs,
UNS level-N descriptions, and prose like 'the #1 bug source' / failover 'pick #3').
Native ADS notifications (the default subscribe mode) were stored as opaque handles
with no record of the symbol/type/interval/handler needed to replay. On a client swap
(EnsureConnectedAsync building a fresh client after a drop) the notifications were
silently orphaned — no Bad status, no error, pushes just stopped until redeploy.
Compounding: the IsConnected fast-path keys on AMS-port state, not wire liveness, and
a probe failure only transitioned state without recycling the dead client.
Fix:
- Store REPLAYABLE INTENT: NativeRegistration (symbol/type/bit/interval/onChange +
swappable live handle) hung off DeviceState.NativeRegistrations, populated by
SubscribeAsync via RegisterNotificationAsync (under ConnectGate).
- Split EnsureConnectedAsync into a gate wrapper + EnsureConnectedUnderGateAsync core;
when the core installs a NEW client it replays every stored intent onto it and swaps
the live handle (disposing the dead one). Register + replay both run under ConnectGate
so they can't race.
- Probe loop: on a wire-probe failure (false or throw) RecycleClientAsync disposes+nulls
the client so the next tick rebuilds + replays — closes the fast-path-keys-on-port-state
compounding bug.
No TwinCAT docker fixture exists (integration needs a real TC3 XAR), so the fake-client
unit tests are the authoritative coverage:
- 4 new guards in TwinCATReconnectReplayTests (replay-onto-fresh-client + push reaches
OnDataChange + old handle disposed; replay-all-tags; unsubscribe-after-reconnect stops
replaying; probe-failure recycles+rebuilds).
- Full TwinCAT unit suite 174/174 green; full solution builds 0 errors.
Adds <summary>/<param>/<returns>/<inheritdoc> where missing and removes
project bookkeeping IDs (task/tracking refs) from shipped code comments,
so the docs read cleanly and CommentChecker is quiet except for known
false positives (PLC/protocol terms, event/IEqualityComparer inheritdoc).
Doc/comment-only; no logic changed; solution builds clean.
Re-review at 7286d320. -017 (Medium): TwinCATTagDto lacked ArrayLength, so JSON-authored
pre-declared array tags were silently scalar (Phase-4c array path dead for them). Fix:
add ArrayLength to the DTO + thread through BuildTag with positive-value guard + TDD.
AdminUI driver-instance pages serialized enum config fields (S7 CpuType,
Modbus DataType/Region, AbCip PlcFamily, ...) as JSON *numbers* because each
page's _jsonOpts lacked a JsonStringEnumConverter. The driver factories,
however, deserialize into string-typed DTOs (+ lenient ParseEnum) and throw
when binding a JSON number to a string? — so an AdminUI-authored config
containing any enum field produced a blob the driver could not parse,
faulting the driver on deploy. Proven end-to-end for S7 and Modbus; latent
for AbCip/AbLegacy/TwinCAT/FOCAS/Galaxy/Historian. Only OpcUaClient was safe
(its factory + probe already carried the converter).
Add JsonStringEnumConverter to all 9 driver-instance pages' _jsonOpts and the
8 missing driver probes' _opts (factories unchanged — already string-via-
ParseEnum; strictly more permissive, also lets pages load hand-seeded
string-enum configs back into the form).
Also fix DriverProbeHandshakeE2eTests.AbCip_Green_AgainstSim to probe a real
sim tag (TestDINT) — the no-tags @raw_cpu_type fallback is rejected by the
ab_server sim with ErrorBadParam (a real ControlLogix returns ErrorNotFound,
which the probe treats as reachable; hardware-gated follow-up).
Tests: reflection guard over all driver pages' _jsonOpts (AdminUI.Tests);
factory round-trip + numeric-form-throws guards for S7 and Modbus.
Found by running the never-before-run FB-9/FB-10 live verifies.
- ITwinCATClient.BrowseSymbolsAsync XML doc updated: states the implementation now
expands struct/UDT/FB symbols into atomic member leaves via TwinCATSymbolExpander;
callers receive only atomic/array leaves with full InstancePaths, never struct containers.
- AdsSymbolNode: cache IsStruct, Mapped, Children, ReadOnly as readonly fields computed
once in the ctor so repeated property access during recursive expansion doesn't
re-materialize or re-invoke MapSymbolType/IsSymbolWritable.
- BrowseSymbolsAsync: add operator-gated live risk note next to SymbolsLoadMode.Flat
warning that a real TC3 target may not populate SubSymbols in Flat mode, with
guidance to switch to VirtualTree if members don't surface — do not change mode now.
- TwinCATSymbolExpanderTests: simplify confusing `new string('.', 0)` no-op to `""`.