bad2aef137eea211661f034239a43a147167ce6c
938 Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
1be0fb5a29 |
Phase 6.2 Stream C.12 — lock in ScopePathIndexBuilder semantics with tests
Closes task #123 (partial — builder semantics unit-tested; production wiring is the new task #133). ScopePathIndexBuilder + NodeScopeResolver indexed mode already exist — they produce a full Cluster → Namespace → UnsArea → UnsLine → Equipment → Tag scope from the published generation's config rows. What was missing: unit coverage of the Build semantics (the only consumers were compile-time references) + explicit acknowledgement in the readiness doc that the gate/resolver aren't yet wired into Program.cs. Tests — 6 cases in ScopePathIndexBuilderTests.cs: - Well-formed content emits full hierarchy. - Tags with null EquipmentId skipped (SystemPlatform-namespace fallback). - Tags with broken Equipment FK skipped (publish-time validation should have caught; builder is defensive). - Equipment with broken Line FK skipped. - Duplicate TagConfig throws InvalidOperationException. - Resolver with index returns full-path scope; un-indexed ref falls through to cluster-only scope (pre-ADR-001 behaviour preserved). Server.Tests 277 → 283. Critical follow-up (task #133): Program.cs still constructs OpcUaApplicationHost WITHOUT authzGate or scopeResolver, so all six dispatch-layer gates (Read, Write, HistoryRead, Browse, CreateMonitoredItems, Call) are currently inert in production. Wiring them up — load NodeAcl + EquipmentNamespaceContent at bootstrap, construct gate + resolver, pass into OpcUaApplicationHost, rebind on generation refresh — is the last Phase 6.2 GA blocker. Docs: v2-release-readiness.md Phase 6.2 Stream C hardening list marks the scope-resolution bullet struck-through with a close-out note that calls out the gate-inert-in-production gap + task #133. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
ded292ecd7 |
Phase 6.2 Stream C — Call + Alarm Acknowledge/Confirm gating
Closes task #122 (Acknowledge + Confirm + generic Call — Shelve stays as a follow-up pending per-instance method-NodeId resolution). Before this commit any session with a connected channel could invoke method nodes on driver-materialized equipment — including alarm Acknowledge / Confirm. Combined with the Browse + CreateMonitoredItems gates that landed earlier in Stream C, this was the last service-layer entry point where a session could still affect state without passing the authz trie. Implementation on DriverNodeManager: - `Call` override — pre-iterates methodsToCall, gates each through AuthorizationGate with the operation kind returned by MapCallOperation. Denied calls get errors[i] = BadUserAccessDenied before delegating to base.Call. - `MapCallOperation(NodeId methodId)` — maps well-known Part 9 method NodeIds to dedicated operation kinds: MethodIds.AcknowledgeableConditionType_Acknowledge → OpcUaOperation.AlarmAcknowledge MethodIds.AcknowledgeableConditionType_Confirm → OpcUaOperation.AlarmConfirm everything else → OpcUaOperation.Call Lets the ACL distinguish "can acknowledge alarms" from "can invoke arbitrary methods" without conflating the two roles. - Shelve dispatch paths through per-instance ShelvedStateMachine methods with dynamic NodeIds that can't be constant-matched — falls through to generic Call. Fine-grained OpcUaOperation.AlarmShelve is a follow- up when the method-invocation path grows a "method-role" annotation. Extracted GateCallMethodRequests + MapCallOperation as static internal for unit-testability. 8 new tests (MapCallOperation Acknowledge / Confirm / generic; gate-null no-op, denied-Acknowledge, allowed- Acknowledge, mixed-batch, pre-populated-error-preserved). Server.Tests 269 → 277. Known follow-ups: - Shelve per-operation gating (see above). - TranslateBrowsePathsToNodeIds gating (Browse follow-up from #120). Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
6a6b0f56f2 |
Phase 6.2 Stream C — CreateMonitoredItems per-item gating
Closes task #121 (partial — creation-time gate; decision #153 per-item revocation stamp is a follow-up). Before this commit a session could subscribe to any node via CreateMonitoredItems, even nodes where Read was denied — the subscription would surface BadUserAccessDenied on each data-change read, but the client saw a successful CreateMonitoredItems response and held the subscription open, wasting resources and leaking the address-space shape through the item metadata. New override on DriverNodeManager.CreateMonitoredItems: - Pre-iterates itemsToCreate, gates each through AuthorizationGate with OpcUaOperation.CreateMonitoredItems at the target node's scope. - For denied slots: sets errors[i] = new ServiceResult( StatusCodes.BadUserAccessDenied). The OPC Foundation base stack honours pre-populated non-success errors and skips item creation for those slots — the subscription never holds a handle to a denied node. - Preserves prior errors (e.g. BadNodeIdUnknown) — first diagnosis wins. - Non-string-identifier references (stack-synthesized numeric ids) bypass the gate. Extracted the pure filter logic into GateMonitoredItemCreateRequests(items, errors, identity, gate, scopeResolver) — static internal, unit-testable without the OPC UA server stack. Tests — 6 new in MonitoredItemGatingTests.cs (gate-null no-op, denied-gets-BadUserAccessDenied, allowed-passes, mixed-batch-denies- per-item, pre-populated-error-preserved, numeric-id-bypass). Server.Tests 263 → 269. Known follow-ups: - Per-item (AuthGenerationId, MembershipVersion) stamp (decision #153) for detecting revocation mid-subscription — needs subscription-layer plumbing. - TransferSubscriptions not yet wired (same pattern, smaller scope). Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
e8b8541554 |
Phase 6.2 Stream C — Browse gating on DriverNodeManager
Closes task #120 (partial — strict point-check; ancestor-visibility implication is a follow-up). Before this commit DriverNodeManager exposed every materialized node to every browsing session regardless of the user's ACL. Read + Write + HistoryRead were already gated through AuthorizationGate in Phase 6.2 Stream C core; Browse was the one surface where the session could still enumerate nodes it had no permission to touch, discovering structure even when reads failed with BadUserAccessDenied. Implementation - New `Browse` override on DriverNodeManager that calls base.Browse first (lets the stack populate the reference list normally), then post-filters the IList<ReferenceDescription> so denied nodes are removed silently. OPC UA convention: Browse filtering is invisible to the client; no BadUserAccessDenied surfaces. - Extracted the filter loop into the static internal `FilterBrowseReferences(references, userIdentity, gate, scopeResolver)` so the policy is unit-testable without standing up the full OPC UA server stack. - Non-string NodeId identifiers (stack-synthesized standard-type references with numeric identifiers) bypass the gate — only driver- materialized nodes key into the authz trie. - When AuthorizationGate or NodeScopeResolver is null, the filter is a no-op — preserves the pre-Phase-6.2 dispatch path for integration tests that construct DriverNodeManager without authz. Tests — 6 new in BrowseGatingTests.cs (gate-null no-op, empty-list no-op, denied-removed, allowed-passes-through, numeric-id bypass, lax-mode null-identity keeps references). Server.Tests 257 → 263. Known follow-up (tracked implicitly under #120 re-scope): - Ancestor-visibility implication (acl-design.md §Browse line 111): a user with Read at `Line/Tag` should be able to Browse `Line` even without an explicit Browse grant. Current filter does a strict point-check. Proper fix needs TriePermissionEvaluator to expose a "subtree-has-any-grant" query. - TranslateBrowsePathsToNodeIds not yet filtered (same extension pattern; small follow-up). Docs: v2-release-readiness.md Phase 6.2 Stream C hardening list marks the Browse bullet struck-through with "Partial" close-out note. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
a23de2a7e4 |
Phase 6.3 A.2 + D.1 — GenerationRefreshHostedService: poll + lease-wrap apply
Closes tasks #132 + #118 (GA hardening backlog). Before this commit, the Server only observed the generation in force at process start (SealedBootstrap). Peer-published generations accumulated in the shared config DB while the running node kept serving the generation it had sealed on boot. Two consequences: 1. Operator role-swaps required a process restart — Admin publishes a new generation, but the Server's RedundancyCoordinator never re-read the topology. 2. ApplyLeaseRegistry had no apply to wrap. ServiceLevelBand sat at PrimaryHealthy (255) during every publish because nothing opened a lease; PrimaryMidApply (200) was effectively dead code. New GenerationRefreshHostedService (src/.../Server/Hosting/): - Polls sp_GetCurrentGenerationForCluster every 5s (tunable). - On change: opens leases.BeginApplyLease(newGenerationId, Guid.NewGuid()), calls coordinator.RefreshAsync inside the `await using`, releases on scope exit (success / exception / cancellation via IAsyncDisposable). - Diagnostic properties: LastAppliedGenerationId, TickCount, RefreshCount. - Delegate-injected currentGenerationQuery for test drive-through; real path is the private static DefaultQueryCurrentGenerationAsync. - Registered as HostedService in Program.cs alongside the Phase 6.3 redundancy / peer-probe stack. Scope intentionally narrow: only the coordinator refreshes today. Driver re-init, virtual-tag re-bind, script-engine reload remain as follow-up wiring. The lease wrap is the right seam for those subscribers to hook once they grow hot-reload support — the doc comments say so. Tests - 5 new unit tests in GenerationRefreshHostedServiceTests (first-apply, identity no-op, change-triggers-refresh, null-generation-is-no-op, lease-is-released-on-exit). Stub generation-query delegate; real coordinator backed by EF InMemory DB. - Server.Tests total 252 → 257. Docs - v2-release-readiness.md Phase 6.3 follow-ups list marks the sp_PublishGeneration lease wrap bullet struck-through with close-out note. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
de77d42eab |
Phase 6.3 Stream B — peer-probe HostedServices populating PeerReachabilityTracker
Closes task #116 (GA hardening backlog). Before this commit the RedundancyStatePublisher saw PeerReachability.Unknown for every peer because the tracker had no writers — every healthy peer got degraded to the Isolated-Primary band (230) even when fully reachable. Not release-blocking (safe default), but not the full non-transparent- redundancy UX either. Two-layer probe model per docs/v2/implementation/phase-6-3-redundancy-runtime.md §Stream B: - PeerHttpProbeLoop (Stream B.1) — fast-fail layer at 2 s / 1 s timeout. Hits each peer's http://{Host}:{DashboardPort}/healthz via an injected IHttpClientFactory. Writes the HTTP bit of PeerReachability while preserving the UA bit from the last UA probe so a transient HTTP blip doesn't clobber the authoritative UA reading. - PeerUaProbeLoop (Stream B.2) — authoritative layer at 10 s / 5 s timeout. Calls DiscoveryClient.GetEndpoints against opc.tcp://{Host}: {OpcUaPort} — cheap compared to a full Session.Create, no cert trust required. Short-circuits when the HTTP probe last reported the peer unhealthy (no wasted handshakes on a known-dead endpoint), clearing the stale UaHealthy bit in that case. Both inherit from BackgroundService, follow the tick/delay/catch pattern RedundancyPublisherHostedService + ResilienceStatusPublisherHostedService established, and expose TickAsync() as internal for test drive-through. New PeerProbeOptions class carries the four intervals/timeouts so operators can tune cadence per site. Registered as singleton in Program.cs; HTTP client registered by name so the OtOpcUa handler chain (Serilog enrichers, potential future OpenTelemetry instrumentation) isn't bypassed. Tests — 9 new unit tests across PeerHttpProbeLoopTests (5) and PeerUaProbeLoopTests (4). All pass. Server.Tests total 243 → 252. Full solution build clean. Docs: v2-release-readiness.md Phase 6.3 follow-ups list marks the peer-probe bullet struck-through with a close-out note. Still deferred in Phase 6.3: - OPC UA variable-node binding (task #117 — ServiceLevel + ServerUriArray) - sp_PublishGeneration lease wrap (task #118) - Client interop matrix (task #119) Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
96918b148c |
Unblock phase-6 compliance meta-runner on task-galaxy-e2e
Two small fixes so `scripts/compliance/phase-6-all.ps1` exits 0 — this is GA exit-criterion #1 from docs/v2/v2-release-readiness.md. 1. Admin csproj: bump OpenTelemetry.Extensions.Hosting 1.15.2 → 1.15.3 + OpenTelemetry.Exporter.Prometheus.AspNetCore 1.15.2-beta.1 → 1.15.3-beta.1. Fixes NU1902 moderate-severity advisory (GHSA-g94r-2vxg-569j) on the transitive OpenTelemetry.Api 1.15.2 pull. TreatWarningsAsErrors on the Admin project promoted the advisory to an error and failed the whole `dotnet test` run at restore. 2. SchemaComplianceTests.All_expected_tables_exist: the expected-tables list drifted behind four Phase 7 migration additions — Script, ScriptedAlarm, ScriptedAlarmState, VirtualTag. The EF model + live migrations have carried these tables for a while; the compliance test just needed the four names added. Applied migrations against a scratch DB to confirm the list is exhaustive. Verification: full solution test pass 2301 / 2301 (one tolerated pre-existing CLI flake). Phase 6 aggregate compliance: all four phases PASS with no test-count regression. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
69e0d02c72 |
task-galaxy-e2e branch — non-FOCAS work-in-progress snapshot
Catch-all commit for pending work on the task-galaxy-e2e branch that
wasn't part of the FOCAS migration. Grouping by topic so future per-topic
commits can be cherry-picked if needed.
TwinCAT
- src/.../Driver.TwinCAT/AdsTwinCATClient.cs + TwinCATDriverFactoryExtensions.cs:
factory-registration extensions + ADS client refinements.
- src/.../Driver.TwinCAT.Cli/Commands/BrowseCommand.cs: new browse command
for the TwinCAT test-client CLI.
- tests/.../Driver.TwinCAT.IntegrationTests/TwinCAT3SmokeTests.cs + TwinCatProject/:
fixture scaffold with a minimal POU + README pointing at the TCBSD/ESXi
VM for e2e.
- docs/Driver.TwinCAT.Cli.md + docs/drivers/TwinCAT-Test-Fixture.md:
documentation for the above.
- docs/v3/twincat-backlog.md: forward-looking backlog seed.
Admin UI + fleet status
- src/.../Admin/Components/Pages/Clusters/DriversTab.razor + Hosts.razor:
UI refresh for fleet-status rendering.
- src/.../Admin/Hubs/FleetStatusHub.cs + FleetStatusPoller.cs +
Admin/Program.cs: SignalR hub + poller plumbing for live fleet data.
- tests/.../Admin.Tests/FleetStatusPollerTests.cs: poller coverage.
Server + redundancy runtime (Phase 6.3 follow-ups)
- src/.../Server/Hosting/RedundancyPublisherHostedService.cs: HostedService
that owns the RedundancyStatePublisher lifecycle + wires peer reachability.
- src/.../Server/Redundancy/ServerRedundancyNodeWriter.cs: OPC UA
variable-node writer binding ServiceLevel + ServerUriArray to the
publisher's events.
- src/.../Server/Program.cs + Server.csproj: hosted-service registration.
- tests/.../Server.Tests/ServerRedundancyNodeWriterTests.cs +
Server.Tests.csproj: coverage for the above.
Configuration
- src/.../Configuration/Validation/DraftValidator.cs +
tests/.../Configuration.Tests/DraftValidatorTests.cs: draft-validation
refinements.
E2E scripts (shared infrastructure)
- scripts/e2e/README.md + _common.ps1 + test-all.ps1: shared helpers + the
all-drivers test-all runner.
- scripts/e2e/test-opcuaclient.ps1: OPC UA Client e2e runner.
Docs
- docs/v2/implementation/phase-6-{1,2,3,4}*.md + exit-gate-phase-{3,7}.md:
phase-gate + implementation doc updates.
- docs/v2/plan.md: top-level plan refresh.
- docs/v2/redundancy-interop-playbook.md: client interop playbook for the
Phase 6.3 redundancy-runtime work.
Two orphan FOCAS docs remain on disk but deliberately unstaged —
docs/v2/focas-deployment.md and docs/v2/implementation/focas-simulator-plan.md
describe the now-retired Tier-C topology and should either be rewritten
or deleted in a follow-up.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|
||
|
|
4b0664bd55 |
FOCAS — retire Tier-C split, inline managed wire client, make read-only
Migration closes the FOCAS Tier-C architecture. OtOpcUa previously had
`Driver.FOCAS.Host` (NSSM-wrapped Windows service loading Fwlib64.dll via
P/Invoke) + `Driver.FOCAS.Shared` (MessagePack IPC contracts) + a C shim
DLL stand-in for unit tests. All of it is deleted; the driver is now a
single in-process managed assembly talking the FOCAS/2 Ethernet binary
protocol directly on TCP:8193.
Architecture
- Pure-managed `FocasWireClient` inlined at `src/.../Driver.FOCAS/Wire/`
(owner-imported — see Wire/FocasWireClient.cs for the full surface).
Opens two TCP sockets, runs the initiate handshake, serialises requests
on socket 2 through a semaphore, closes cleanly with PDU + socket
teardown. Both sync `IDisposable` and async `IAsyncDisposable`.
- `WireFocasClient` (same folder) adapts the wire client to OtOpcUa's
`IFocasClient` surface — fixed-tree reads, PARAM/MACRO/PMC addresses,
alarms. Writes return `BadNotWritable` by design — OtOpcUa is read-only
against FOCAS.
- `FocasDriverFactoryExtensions` now accepts `"Backend": "wire"` (default)
and `"Backend": "unimplemented"`. Legacy `ipc` and `fwlib` backends are
rejected at startup with a diagnostic pointing at the migration doc.
Deletions
- `src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Host/` — whole project + Ipc/,
Backend/, Stability/, Program.cs.
- `src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Shared/` — Contracts/, FrameReader,
FrameWriter, whole project.
- `tests/...Driver.FOCAS.Host.Tests/` + `.Shared.Tests/` — whole projects.
- `src/.../Driver.FOCAS/FwlibNative.cs` + `FwlibFocasClient.cs` — 21
P/Invokes + 7 `Pack=1` marshalling structs + the Fwlib-backed
`IFocasClient` implementation.
- `src/.../Driver.FOCAS/Ipc/` + `Supervisor/` — IPC client wrapper +
Host-process supervisor (backoff, circuit breaker, heartbeat, post-
mortem reader, process launcher).
- `scripts/install/Install-FocasHost.ps1` — NSSM service installer.
- `tests/.../Driver.FOCAS.Tests/{IpcFocasClientTests, IpcLoopback,
FwlibNativeHelperTests, PostMortemReaderCompatibilityTests,
SupervisorTests, FocasDriverFactoryExtensionsTests}.cs` — tests that
exercised the retired surfaces.
- `tests/.../Driver.FOCAS.IntegrationTests/Shim/` — the zig-built C shim
DLL that masqueraded as Fwlib64.dll.
Solution changes
- `ZB.MOM.WW.OtOpcUa.slnx` drops the 4 retired project refs.
- `src/.../Driver.FOCAS.csproj` drops the Shared ProjectReference, adds
`Microsoft.Extensions.Logging.Abstractions` for the optional `ILogger`
hook in `FocasWireClient`.
- `src/.../Driver.FOCAS.Cli.csproj` drops the six `<Content Include>`
entries that copied `vendor/fanuc/*.dll` into the CLI bin. CLI now uses
`WireFocasClient` directly.
- `FocasDriver` default factory flips to `Wire.WireFocasClientFactory`.
Integration tests
- New `tests/.../Driver.FOCAS.IntegrationTests/` project covering fixed-
tree reads (identity, axes, dynamic, program, operation mode, timers,
spindle load + max RPM, servo meters), user-authored PARAM / MACRO /
PMC reads, `DiscoverAsync` emission, `SubscribeAsync` + `OnDataChange`,
`IAlarmSource` raise/clear transitions, and `ProbeAsync` /
`OnHostStatusChanged`. 9 e2e tests against the focas-mock fixture
(Docker container with the vendored Python mock's native FOCAS/2
Ethernet responder).
- `scripts/integration/run-focas.ps1` orchestrates compose up → tests →
compose down. Dropped the shim-build stage + DLL-copy step + the split
testhost workaround (the latter only existed because of native-DLL
lifecycle bugs the shim tripped).
- Docker compose collapses from 11 per-series services to one `focas-sim`
service. Tests seed per-series state via `mock_load_profile` at test
start.
- Vendored focas-mock snapshot refreshed to pick up upstream's native
FOCAS/2 Ethernet responder (was 660 lines, now 1018) — the
pre-refresh snapshot only spoke the JSON admin protocol.
Tests
- 145/145 unit tests in `Driver.FOCAS.Tests` pass (was 208 pre-deletion;
63 removed tests exercised the retired IPC/shim/supervisor/Fwlib
surfaces).
- 9/9 integration tests pass against the refreshed mock.
- `FocasScaffoldingTests.Unimplemented_factory_throws_on_Create…` updated
to assert the new diagnostic message pointing at
`docs/drivers/FOCAS.md` rather than the now-gone `Fwlib64.dll`.
Docs
- `docs/drivers/FOCAS.md` rewritten for the managed wire topology —
deployment collapses to one `"Backend": "wire"` config block, no
separate service, no DLL deployment, no pipe ACL.
- `docs/drivers/FOCAS-Test-Fixture.md` updated — single TCP probe skip
gate instead of TCP + shim probe; fewer moving parts.
- `docs/drivers/README.md` row for FOCAS reflects the Tier-A managed
topology (previously listed Tier-C + `Fwlib64.dll` P/Invoke).
- `docs/Driver.FOCAS.Cli.md` drops the Tier-C architecture-note section.
- `docs/v2/implementation/focas-isolation-plan.md` marked historical —
the plan it documents was executed then superseded by the wire client.
- `docs/v2/v2-release-readiness.md` re-audited 2026-04-24. Phase 5
driver complement closed. FOCAS change-log entry added.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|
||
|
|
404b54add0 |
FOCAS — commit previously-orphaned support files
Brings seven FOCAS-related files into git that shipped as part of earlier FOCAS work but were never staged. Adding them now so the tree reflects the compilable state + pre-empts dead references from the migration commit that follows: - src/.../Driver.FOCAS/FocasAlarmProjection.cs — raise/clear diffing + severity mapping surfaced via IAlarmSource on FocasDriver. Referenced by committed FocasDriver.cs; tests in FocasAlarmProjectionTests.cs. - src/.../Admin/Services/FocasDriverDetailService.cs — Admin UI per-instance detail page data source. - src/.../Admin/Components/Pages/Drivers/FocasDetail.razor — Blazor page rendering the above (from task #69). - tests/.../Admin.Tests/FocasDriverDetailServiceTests.cs — exercises the detail service. - tests/.../Driver.FOCAS.Tests/FocasAlarmProjectionTests.cs — raise/clear diff semantics against FakeFocasClient. - tests/.../Driver.FOCAS.Tests/FocasHandleRecycleTests.cs — proactive recycle cadence test. - docs/v2/implementation/focas-wire-protocol.md — captured FOCAS/2 Ethernet wire protocol reference. Useful going forward even though the Tier-C / simulator plan docs are historical. No runtime behaviour change — these files compile today and the solution build/test pass already depends on them. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
21e0fdd4cd |
Docs audit — fill gaps so the top-level docs/ reference matches shipped code
Audit of docs/ against src/ surfaced shipped features without current-reference coverage (FOCAS CLI, Core.Scripting+VirtualTags, Core.ScriptedAlarms, Core.AlarmHistorian), an out-of-date driver count + capability matrix, ADR-002's virtual-tag dispatch not reflected in data-path docs, broken cross-references, and OpcUaServerReqs declaring OPC-020..022 that were never scoped. This commit closes all of those so operators + integrators can stay inside docs/ without falling back to v2/implementation/. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
5fc596a9a1 |
E2E test script — Galaxy (MXAccess) driver: read / write / subscribe / alarms / history
Seven-stage e2e script covering every Galaxy-specific capability surface:
IReadable + IWritable + ISubscribable + IAlarmSource + IHistoryProvider.
Unlike the other drivers there is no per-protocol CLI — Galaxy's proxy
lives in-process with the server + talks to OtOpcUaGalaxyHost over a
named pipe (MXAccess COM is 32-bit-only), so every stage runs through
`otopcua-cli` against the published OPC UA address space.
## Stages
1. Probe — otopcua-cli read on the source NodeId
2. Source read — capture value for downstream comparison
3. Virtual-tag bridge — Phase 7 VirtualTag (source × 2) through
CachedTagUpstreamSource
4. Subscribe-sees-change — data-change events propagate
5. Reverse bridge — opc-ua write → Galaxy; soft-passes if the
attribute's Galaxy-side ACL forbids writes
(`BadUserAccessDenied` / `BadNotWritable`)
6. Alarm fires — scripted-alarm Condition fires with Active
state when source crosses threshold
7. History read — historyread returns samples from the Aveva
Historian → IHistoryProvider path
## Two new helpers in _common.ps1
- `Test-AlarmFiresOnThreshold` — start `otopcua-cli alarms --refresh`
in the background on a Condition NodeId, drive the source change,
assert captured stdout contains `ALARM` + `Active`. Uses the same
Start-Process + temp-file pattern as `Test-SubscribeSeesChange` since
the alarms command runs until Ctrl+C (no built-in --duration).
- `Test-HistoryHasSamples` — call `otopcua-cli historyread` over a
configurable lookback window, parse `N values returned.` marker, fail
if below MinSamples. Works for driver-sourced, virtual, or scripted-
alarm historized nodes.
## Wiring
- `test-all.ps1` picks up the optional `galaxy` sidecar section and
runs the script with the configured NodeIds + wait windows.
- `e2e-config.sample.json` adds a `galaxy` section seeded with the
Phase 7 defaults (`p7-smoke-tag-source` / `-vt-derived` /
`-al-overtemp`) — matches `scripts/smoke/seed-phase-7-smoke.sql`.
- `scripts/e2e/README.md` expected-matrix gains a Galaxy row.
## Prereqs
- OtOpcUaGalaxyHost running (NSSM-wrapped) with the Galaxy + MXAccess
runtime available
- `seed-phase-7-smoke.sql` applied with a live Galaxy attribute
substituted into `dbo.Tag.TagConfig`
- OtOpcUa server running against the `p7-smoke` cluster
- Non-elevated shell (Galaxy.Host pipe ACL denies Admins)
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|
||
|
|
05d2a7fd00 | Merge pull request 'Task #222 partial — unblock AB Legacy PCCC via cip-path workaround (5/5 stages)' (#223) from task-222-ablegacy-pccc-unblock into v2 | ||
|
|
95c7e0b490 |
Task #222 partial — unblock AB Legacy PCCC via cip-path workaround (5/5 stages)
Replaced the "ab_server PCCC upstream-broken" skip gate with the actual
root cause: libplctag's ab_server rejects empty CIP routing paths at the
unconnected-send layer before the PCCC dispatcher runs. Real SLC/
MicroLogix/PLC-5 hardware accepts empty paths (no backplane); ab_server
does not. With `/1,0` in place, N (Int16), F (Float32), and L (Int32)
file reads + writes round-trip cleanly across all three compose profiles.
## Fixture changes
- `AbLegacyServerFixture.cs`:
- Drop `AB_LEGACY_TRUST_WIRE` env var + the reachable-but-untrusted
skip branch. Fixture now only skips on TCP unreachability.
- Add `AB_LEGACY_CIP_PATH` env var (default `1,0`) + expose `CipPath`
property. Set `AB_LEGACY_CIP_PATH=` (empty) against real hardware.
- Shorter skip messages on the `[AbLegacyFact]` / `[AbLegacyTheory]`
attributes — one reason: endpoint not reachable.
- `AbLegacyReadSmokeTests.cs`:
- Device URI built from `sim.CipPath` instead of hardcoded empty path.
- New `AB_LEGACY_COMPOSE_PROFILE` env var filters the parametric
theory to the running container's family. Only one container binds
`:44818` at a time, so cross-family params would otherwise fail.
- `Slc500_write_then_read_round_trip` skips cleanly when the running
profile isn't `slc500`.
## E2E + seed + docs
- `scripts/e2e/test-ablegacy.ps1` — drop the `AB_LEGACY_TRUST_WIRE`
skip gate; synopsis calls out the `/1,0` vs empty cip-path split
between the Docker fixture and real hardware.
- `scripts/e2e/e2e-config.sample.json` — sample gateway flipped from
the hardware placeholder (`192.168.1.10`) to the Docker fixture
(`127.0.0.1/1,0`); comment rewritten.
- `scripts/e2e/README.md` — AB Legacy expected-matrix row goes from
SKIP to PASS.
- `scripts/smoke/seed-ablegacy-smoke.sql` — default HostAddress points
at the Docker fixture + header / footer text reflect the new state.
- `tests/.../Docker/README.md` — "Known limitations" section rewritten
to describe the cip-path gate (not a dispatcher gap); env-var table
picks up `AB_LEGACY_CIP_PATH` + `AB_LEGACY_COMPOSE_PROFILE`.
- `docs/drivers/AbLegacy-Test-Fixture.md` + `docs/drivers/README.md`
+ `docs/DriverClis.md` — flip status from blocked to functional;
residual bit-file-write gap (B3:0/5 → 0x803D0000) documented.
## Residual gap
Bit-file writes (`B3:0/5` style) surface `0x803D0000` against
`ab_server --plc=SLC500`; bit reads work. Non-blocking for smoke
coverage — N/F/L round-trip is enough. Real hardware / RSEmulate 500
for bit-write fidelity. Documented in `Docker/README.md` §"Known
limitations" + the `AbLegacy-Test-Fixture.md` follow-ups list.
## Verified
- Full-solution build: 0 errors, 334 pre-existing warnings.
- Integration suite passes per-profile with
`AB_LEGACY_COMPOSE_PROFILE=<slc500|micrologix|plc5>` + matching
compose container up.
- All four non-hardware e2e scripts (Modbus / AB CIP / AB Legacy / S7)
now 5/5 against the respective docker-compose fixtures.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|
||
|
|
e1f172c053 | Merge pull request 'Task #220 — AB CIP + S7 live-boot verification (5/5 stages each)' (#222) from task-220-exitgate-abcip-s7 into v2 | ||
|
|
6d290adb37 |
Task #220 — AB CIP + S7 live-boot verification (5/5 stages each)
Replicated the Modbus #218 bring-up against the AB CIP + S7 seeds to confirm the factories + seeds shipped in #217 actually work end-to-end. Both pass 5/5 e2e stages with `OpcUaServer:AnonymousRoles=[WriteOperate]` (the #221 knob). ## AB CIP (against ab_server controllogix fixture, port 44818) ``` === AB CIP e2e summary: 5/5 passed === [PASS] Probe [PASS] Driver loopback [PASS] Server bridge (driver → server → client) [PASS] OPC UA write bridge (client → server → driver) [PASS] Subscribe sees change ``` Server log: `DriverInstance abcip-smoke-drv (AbCip) registered + initialized` ✓. ## S7 (against python-snap7 s7_1500 fixture, port 1102) ``` === S7 e2e summary: 5/5 passed === [PASS] Probe [PASS] Driver loopback [PASS] Server bridge [PASS] OPC UA write bridge [PASS] Subscribe sees change ``` Server log: `DriverInstance s7-smoke-drv (S7) registered + initialized` ✓. ## Seed fixes so bring-up is idempotent Live-boot exposed two seed-level papercuts when applying multiple smoke seeds in sequence: 1. **SA credential collision.** `UX_ClusterNodeCredential_Value` is a unique index on `(Kind, Value) WHERE Enabled=1`, so `sa` can only bind to one node at a time. Each seed's DELETE block only dropped the credential tied to ITS node — seeding AbCip after Modbus blew up with `Cannot insert duplicate key` on the sa binding. Added a global `DELETE FROM dbo.ClusterNodeCredential WHERE Kind='SqlLogin' AND Value='sa'` before the per-cluster INSERTs. Production deployments using non-SA logins aren't affected. 2. **DashboardPort 5000 → 15050.** `HealthEndpointsHost` uses `HttpListener`, which rejects port 5000 on Windows without a `netsh http add urlacl` grant or admin rights. 15050 is unreserved + loopback-safe per the HealthEndpointsHost remarks. Applied to all four smoke seeds (Modbus was patched at runtime in #218; now baked into the seed). ## AB Legacy status Not live-boot verified — ab_server PCCC dispatcher is upstream-broken (#222). The factory + seed ship ready for hardware; the seed's DELETE + DashboardPort fixes land in this PR so when real SLC/MicroLogix/PLC-5 arrives the sql just applies. ## Closes #220 Umbrella #209 was already closed; #220 was the final child. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
cc8a6c9ec1 | Merge pull request 'Task #219 — OpcUaServerOptions.AnonymousRoles (5/5 e2e stages pass)' (#221) from task-219-anonymous-roles into v2 | ||
|
|
2ec6aa480e |
Task #219 — OpcUaServerOptions.AnonymousRoles (5/5 e2e stages pass)
Anonymous OPC UA sessions had no roles (`UserIdentity()`), so
`WriteAuthzPolicy.IsAllowed(SecurityClassification.Operate, [])`
rejected every write with `BadUserAccessDenied`. The reverse-write
stage of the Modbus e2e script surfaced this: stages 1-3 + 5 pass
forward-direction, stage 4 (OPC UA client → server → driver → PLC)
blew up with `0x801F0000` even with the factory + seed perfectly
wired.
Adds a single config knob:
"OpcUaServer": {
"AnonymousRoles": ["WriteOperate"]
}
Default empty preserves the pre-existing production-safe behaviour
(anonymous reads FreeAccess tags, rejected on everything else). When
non-empty, `OtOpcUaServer.OnImpersonateUser` wraps the anonymous token
in a `RoleBasedIdentity("(anonymous)", "Anonymous", AnonymousRoles)`
so the server-layer write guard sees the configured roles.
Wire-through:
- OpcUaServerOptions.AnonymousRoles (new)
- OpcUaApplicationHost passes it to OtOpcUaServer ctor
- OtOpcUaServer new anonymousRoles ctor param + OnImpersonateUser
branch
- Program.cs reads `OpcUaServer:AnonymousRoles` section from config
Env override syntax: `OpcUaServer__AnonymousRoles__0=WriteOperate`.
## Verified live
Booted server against `seed-modbus-smoke.sql` with
`OpcUaServer__AnonymousRoles__0=WriteOperate` + pymodbus fixture →
`test-modbus.ps1 -BridgeNodeId "ns=2;s=HR200"`:
=== Modbus e2e summary: 5/5 passed ===
[PASS] Probe
[PASS] Driver loopback
[PASS] Server bridge (driver → server → client)
[PASS] OPC UA write bridge (client → server → driver)
[PASS] Subscribe sees change
All five stages green end-to-end. Issue #219 closed by this PR; the
Modbus-seed update to set AnonymousRoles lives in the follow-up #220
live-boot PR (same AnonymousRoles value applies to every driver since
the classification is a driver-constant, not per-tag).
Full-solution build: 0 errors, only pre-existing xUnit1051 warnings.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|
||
|
|
682c1c5e75 | Merge pull request 'Task #209 exit gate — seed-creds fix + live Modbus verification (4/5 stages)' (#218) from task-209-exitgate-seed-creds into v2 | ||
|
|
e8172f9452 |
Task #209 exit gate — seed-creds fix + live Modbus verification (4/5 stages)
Booted the server against the Modbus seed end-to-end to exercise the factory wiring shipped in #216 + #217. Surfaced two real issues with the seeds themselves; fixed both: 1. **Missing ClusterNodeCredential.** `sp_GetCurrentGenerationForCluster` enforces `ClusterNodeCredential.Value = SUSER_SNAME()` and aborts with `RAISERROR('Unauthorized: caller sa is not bound to NodeId')`. All four seed scripts now insert the binding row alongside the ClusterNode row. Without this, the server fails bootstrap with `BootstrapException: Central DB unreachable and no local cache available` (the Unauthorized error gets swallowed on top of the HTTP fallback path). 2. **Config cache gitignore.** Running the server from the repo root writes `config_cache.db` + `config_cache-log.db` next to the cwd, outside the existing `src/.../Server/config_cache.db` pattern. Add a `config_cache*.db` pattern so any future run location is covered. ## Verified live against Modbus Booted server against `seed-modbus-smoke.sql` → pymodbus standard fixture → ran `scripts/e2e/test-modbus.ps1 -BridgeNodeId "ns=2;s=HR200"`: === Modbus e2e summary: 4/5 passed === [PASS] Probe [PASS] Driver loopback [PASS] Server bridge (driver → server → client) [FAIL] OPC UA write bridge (0x801F0000) [PASS] Subscribe sees change The forward direction + subscription delivery are proven working through the server. The reverse-write failure is a seed-or-ACL issue — server log shows no exception on the write path, so the client-side status is coming from the stack's type/ACL guards. Tracking as a follow-up issue so the remaining three factory wirings can be smoke-booted against the same pattern. Note for future runs: two stale v1 `ZB.MOM.WW.LmxOpcUa.Host.exe` processes from `C:\publish\lmxopcua\instance{1,2}\` squat on ports 4840 + 4841 on this dev box; kill them first or bump the seed's DashboardPort. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
3af746c4b6 | Merge pull request 'Tasks #211 #212 #213 — AbCip / S7 / AbLegacy server-side factories + seed SQL' (#217) from task-211-212-213-factories into v2 | ||
|
|
7ba783de77 |
Tasks #211 #212 #213 — AbCip / S7 / AbLegacy server-side factories + seed SQL
Parent: #209. Follow-up to #210 (Modbus). Registers the remaining three non-Galaxy driver factories so a Config DB `DriverType` in {`AbCip`, `S7`, `AbLegacy`} actually boots a live driver instead of being silently skipped by DriverInstanceBootstrapper. Each factory follows the same shape as ModbusDriverFactoryExtensions + the existing Galaxy + FOCAS patterns: - Static `Register(DriverFactoryRegistry)` entry point. - Internal `CreateInstance(driverInstanceId, driverConfigJson)` — deserialises a DTO, strict-parses enum fields (fail-fast with an explicit "expected one of" list), composes the driver's options object, returns a new driver. - DriverType keys: `"AbCip"`, `"S7"`, `"AbLegacy"` (case-insensitive at the registry layer). DTO surfaces cover every option the respective driver's Options class exposes — devices, tags, probe, timeouts, per-driver quirks (AbCip `EnableControllerBrowse` / `EnableAlarmProjection`, S7 Rack/Slot/ CpuType, AbLegacy PlcFamily). Seed SQL (mirrors `seed-modbus-smoke.sql` shape): - `seed-abcip-smoke.sql` — `abcip-smoke` cluster + ControlLogix device + `TestDINT:DInt` tag, pointing at the ab_server compose fixture (`ab://127.0.0.1:44818/1,0`). - `seed-s7-smoke.sql` — `s7-smoke` cluster + S71500 CPU + `DB1.DBW0:Int16` tag at the python-snap7 fixture (`127.0.0.1:1102`, non-priv port). - `seed-ablegacy-smoke.sql` — `ablegacy-smoke` cluster + SLC 500 + `N7:5` tag. Hardware-gated per #222; placeholder gateway to be replaced with real SLC/MicroLogix/PLC-5/RSEmulate before running. Build plumbing: - Each driver project now ProjectReferences `Core` (was `Core.Abstractions`-only). `DriverFactoryRegistry` lives in `Core.Hosting` so the factory extensions can't compile without it. Matches the FOCAS + Galaxy.Proxy reference shape. - `Server.csproj` adds the three new driver ProjectReferences so Program.cs resolves the symbols at compile-time + ships the assemblies at runtime. Full-solution build: 0 errors, 334 pre-existing xUnit1051 warnings only. Live boot verification of all four (Modbus + these three) happens in the exit-gate PR — factories + seeds are pre-conditions and are being shipped first so the exit-gate PR can scope to "does the server publish the expected NodeIds + does the e2e script pass." Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
35d24c2f80 | Merge pull request 'Task #210 — Modbus server-side factory + seed SQL' (#216) from task-210-modbus-factory-seed into v2 | ||
|
|
55245a962e |
Task #210 — Modbus server-side factory + seed SQL (closes first of #209 umbrella)
Parent: #209. Adds the server-side wiring so a Config DB `DriverType='Modbus'` row actually boots a Modbus driver instance + publishes its tags under OPC UA NodeIds, instead of being silently skipped by DriverInstanceBootstrapper. Changes: - `ModbusDriverFactoryExtensions` (new) — mirrors `GalaxyProxyDriverFactoryExtensions` + `FocasDriverFactoryExtensions`. `DriverTypeName="Modbus"`, `CreateInstance` deserialises `ModbusDriverConfigDto` (Host/Port/UnitId/TimeoutMs/Probe/Tags) to a full `ModbusDriverOptions` and hands back a `ModbusDriver`. Strict enum parsing (Region / DataType / ByteOrder / StringByteOrder) — unknown values fail fast with an explicit "expected one of" error rather than at first read. - `Program.cs` — register the factory after Galaxy + FOCAS. - `Driver.Modbus.csproj` — add `Core` project reference (the DI-free factory needs `DriverFactoryRegistry` from `Core.Hosting`). Matches the FOCAS driver's reference shape. - `Server.csproj` — add the `Driver.Modbus` ProjectReference so the Program.cs registration compiles against the same assembly the server loads at runtime. - `scripts/smoke/seed-modbus-smoke.sql` (new) — one-cluster smoke seed modelled on `seed-phase-7-smoke.sql`. Creates a `modbus-smoke` cluster + `modbus-smoke-node` + Draft generation + Namespace + UnsArea/UnsLine/ Equipment + one Modbus `DriverInstance` pointing at the pymodbus standard fixture (`127.0.0.1:5020`) + one Tag at `HR[200]:UInt16`, ending in `EXEC sp_PublishGeneration`. HR[100] is deliberately *not* used because pymodbus `standard.json` runs an auto-increment action on that register. Full-solution build: 0 errors, only the pre-existing xUnit1051 warnings. AB CIP / S7 / AB Legacy factories follow in their own PRs per #211 / #212 / #213. Live boot verification happens in the exit-gate PR once all four factories are in place. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
16d9592a8a | Merge pull request 'Task #253 follow-up — fix test-all.ps1 StrictMode crash on missing JSON keys' (#215) from task-253d-e2e-debug-harness into v2 | ||
|
|
2666a598ae |
Task #253 follow-up — fix test-all.ps1 StrictMode crash on missing JSON keys
Running `test-all.ps1` end-to-end with a partial sidecar (only modbus/
abcip/s7 populated, no focas/twincat/phase7) crashed:
[FAIL] modbus runner crashed: The property 'opcUaUrl' cannot be
found on this object. Verify that the property exists.
Root cause: `_common.ps1` sets `Set-StrictMode -Version 3.0`, which
turns missing-property access on PSCustomObject into a throw. Every
`$config.<driver>.<optional-field> ?? $default` and `if
($config.<missing-section>)` check is therefore unsafe against a
normal JSON where optional fields are omitted.
Fix: switch to `ConvertFrom-Json -AsHashtable` and add a `Get-Or`
helper. Hashtables tolerate `.ContainsKey()` / indexer access even
under StrictMode, so the per-driver sections now read:
$modbus = Get-Or $config "modbus"
if ($modbus) {
... -OpcUaUrl (Get-Or $modbus "opcUaUrl" $OpcUaUrl) ...
}
Verified end-to-end with live docker-compose fixtures:
- Modbus / AB CIP / S7 each run to completion, report 2/5 PASS (the
driver-only stages) and FAIL the 3 server-bridge stages (expected —
server-side factory wiring is blocked on #209).
- The FINAL MATRIX header renders cleanly with SKIP rows for the
drivers not present in the sidecar + FAIL rows for the present ones.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|
||
|
|
5834d62906 | Merge pull request 'Task #253 follow-up — driver-side e2e debug: port fixes + HR[200] scratch register' (#214) from task-253c-e2e-debug-driver-side into v2 | ||
|
|
fe981b0b7f |
Task #253 follow-up — driver-side e2e debug: port fixes + HR[200] scratch register
Ran the driver CLIs against the live docker-compose fixtures to debug
what actually works. Two real bugs surfaced:
1. `e2e-config.sample.json` pointed at the wrong simulator ports:
- Modbus: 5502 → **5020** (pymodbus compose binding)
- S7: 102 → **1102** (python-snap7, non-priv port)
- AbCip: no port → now explicit **:44818**
`test-modbus.ps1` default `-ModbusHost` also shipped with 5502;
fixed to 5020.
2. Modbus loopback was off-by-2 because pymodbus `standard.json` makes
HR[100] an auto-increment register (value ticks on every poll).
Switched `test-modbus.ps1` to **HR[200]** (scratch range in the
profile) + updated sample config `bridgeNodeId` to match.
Also fixed the AbCip probe: `-t @raw_cpu_type` was rejected by the
driver's TagPath parser ("malformed TagPath"). Probe now uses the
user-supplied `-TagPath` for every family. Works against both
ab_server and real controllers.
Verified driver-side against live containers:
- Modbus 5020: probe ✓, HR[200] write+read round-trip ✓
- AB CIP 44818: probe ✓, TestDINT write+read round-trip ✓
- S7 1102: probe ✓, DB1.DBW0 write+read round-trip ✓
## Known blocker (stages 3-5)
README now flags — and the 4 child issues under umbrella #209 track —
that `src/ZB.MOM.WW.OtOpcUa.Server/Program.cs:98-104` only registers
Galaxy + FOCAS driver factories. `DriverInstanceBootstrapper` silently
skips any `DriverType` without a registered factory, so stages 3-5
(anything crossing the OPC UA server) can't work today even with a
perfect Config DB seed. Issues #210-213 scope the factory + seed SQL
work per driver.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|
||
|
|
7b1c910806 | Merge pull request 'Task #253 follow-up — bidirectional + subscribe-sees-change e2e stages' (#208) from task-253b-e2e-bidirectional into v2 | ||
|
|
a9b585ac5b |
Task #253 follow-up — bidirectional + subscribe-sees-change e2e stages
The original three-stage design (probe / driver-loopback / forward- bridge) only proved driver-write → server-read. It missed: - OPC UA write → server → driver → PLC (the reverse direction) - server-side data-change notifications actually firing (a stale subscription can still let a read-after-the-fact return the new value and look fine) Extend _common.ps1 with two helpers: - Test-OpcUaWriteBridge: otopcua-cli write the NodeId -> wait 3s -> driver CLI read the PLC side, assert equality. - Test-SubscribeSeesChange: Start-Process otopcua-cli subscribe in the background with --duration N, settle 2s, driver-side write, wait for the subscription window to close, assert captured stdout contains the new value. Wire both into test-modbus / test-abcip / test-ablegacy / test-s7 / test-focas / test-twincat after the existing forward-bridge stage. Update README to describe the five-stage design + note that the published NodeId must be writable for stages 4 + 5. Also prepend UTF-8 BOM to every script in scripts/e2e so Windows PowerShell 5.1 parsers agree on em-dash byte sequences the way PowerShell 7 already does. The scripts still #Requires -Version 7.0 — the BOM is purely defensive for IDE / CI step parsers. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
097f92fdb8 | Merge pull request 'Task #253 — E2E CLI test scripts + FOCAS test-client CLI' (#207) from task-253-e2e-cli-test-scripts into v2 | ||
|
|
8d92e00e38 |
Task #253 — E2E CLI test scripts + FOCAS test-client CLI
The driver-layer integration tests confirm the driver sees the PLC, and
the Client.CLI tests confirm the client sees the server. Nothing glued
them end-to-end until this PR.
- scripts/e2e/_common.ps1: shared helpers — CLI invocation (published-
binary OR `dotnet run` fallback), Test-Probe / Test-DriverLoopback /
Test-ServerBridge (all return @{Passed;Reason} hashtables).
- scripts/e2e/test-<modbus|abcip|ablegacy|s7|focas|twincat>.ps1: per-
driver three-stage script (probe → driver-loopback → server-bridge).
AB Legacy / FOCAS / TwinCAT are gated behind *_TRUST_WIRE env vars
since they need real hardware (#222) or a licensed runtime (#221).
- scripts/e2e/test-phase7-virtualtags.ps1: writes a Modbus HR, reads
the server-side VirtualTag (VT = input * 2) back via OPC UA, triggers
+ clears a scripted alarm. Exercises the Phase 7 CachedTagUpstreamSource
+ ScriptedAlarmEngine path.
- scripts/e2e/test-all.ps1: reads e2e-config.json sidecar, runs each
present driver, prints a FINAL MATRIX (PASS/FAIL/SKIP). Missing
sections SKIP rather than fail hard.
- scripts/e2e/e2e-config.sample.json: commented sample — each dev's
NodeIds are local-seed-specific so e2e-config.json is .gitignore-d.
- scripts/e2e/README.md: full walkthrough — prereqs, three-stage design,
env-var gates, expected matrix, why this is separate from `dotnet test`.
Tasks #249-#251 shipped Modbus/AbCip/AbLegacy/S7/TwinCAT CLIs but left
FOCAS out. Since test-focas.ps1 needs it, the 6th CLI ships here:
- src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Cli: probe/read/write/subscribe
commands, AssemblyName `otopcua-focas-cli`. WriteCommand.ParseValue
handles the full FocasDataType enum (Bit/Byte/Int16/Int32/Float32/
Float64/String — no UInt variants; the FOCAS protocol exposes signed
PMC + Fanuc-Float only). Default DataType is Int16 to match the PMC
register convention.
Full-solution build clean (0 errors). FOCAS CLI wired into
ZB.MOM.WW.OtOpcUa.slnx. No .Tests project for the FOCAS CLI yet —
symmetric with how ProbeCommand has no unit-testable pure logic in the
other 5 CLIs either; WriteCommand.ParseValue parity will land in a
follow-up to keep this PR scoped.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|
||
|
|
1507486b45 | Merge pull request 'Task #252 — docs/ index + parent doc for the driver CLI suite' (#206) from task-252-driver-cli-index into v2 | ||
|
|
adce4e7727 |
Task #252 — docs/ index + parent doc for the driver CLI suite
Per-CLI runbooks (Driver.{Modbus,AbCip,AbLegacy,S7,TwinCAT}.Cli.md) shipped
with #249-#251 but docs/README.md's Client tooling table never grew entries
for them and there was no parent doc pulling the suite together.
Adds:
- docs/DriverClis.md — short parent. Index table, shared-commands callout
(probe / read / write / subscribe), Driver.Cli.Common infrastructure
note (what's shared, marginal cost of adding a sixth CLI), typical
cross-CLI workflows (commissioning, bug reproduction, recipe-write
validation, byte-order debugging), known gaps that cross-ref the
per-CLI docs (AB Legacy ab_server upstream gap, S7 PUT/GET enable,
TwinCAT AMS router, UDT-write refusal), tracking pointer to #249-251.
- docs/README.md — Client tooling table grows 6 rows (DriverClis parent
+ 5 per-CLI). Also corrects the Client.CLI.md row: it's otopcua-cli,
not lmxopcua-cli (renamed in #208).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|
||
|
|
4446a3ce5b | Merge pull request 'Task #251 — S7 + TwinCAT test-client CLIs (driver CLI suite complete)' (#205) from task-251-s7-twincat-cli into v2 | ||
|
|
4dc685a365 |
Task #251 — S7 + TwinCAT test-client CLIs (driver CLI suite complete)
Final two of the five driver test clients. Pattern carried forward from #249 (Modbus) + #250 (AB CIP, AB Legacy) — each CLI inherits Driver.Cli.Common for DriverCommandBase + SnapshotFormatter and adds a protocol-specific CommandBase + 4 commands (probe / read / write / subscribe). New projects: - src/ZB.MOM.WW.OtOpcUa.Driver.S7.Cli/ — otopcua-s7-cli. S7CommandBase carries host/port/cpu/rack/slot/timeout. Handles all S7 atomic types (Bool, Byte, Int16..UInt64, Float32/64, String, DateTime). DateTime parses via RoundtripKind so "2026-04-21T12:34:56Z" works. - src/ZB.MOM.WW.OtOpcUa.Driver.TwinCAT.Cli/ — otopcua-twincat-cli. TwinCATCommandBase carries ams-net-id + ams-port + --poll-only toggle (flips UseNativeNotifications=false). Covers the full IEC 61131-3 atomic set: Bool, SInt/USInt, Int/UInt, DInt/UDInt, LInt/ULInt, Real, LReal, String, WString, Time/Date/DateTime/TimeOfDay. Structure writes refused as out-of-scope (same as AB CIP). IEC time/date variants marshal as UDINT on the wire per IEC spec. Subscribe banner announces "ADS notification" vs "polling" so the mechanism is obvious in bug reports. Tests (49 new, 122 cumulative driver-CLI): - S7: 22 tests. Every S7DataType has a happy-path + bounds case. DateTime round-trips an ISO-8601 string. Tag-name synthesis round-trips every S7 address form (DB / M / I / Q, bit/word/dword, strings). - TwinCAT: 27 tests. Full IEC type matrix including WString UTF-8 pass- through + the four IEC time/date variants landing on UDINT. Structure rejection case. Tag-name synthesis for Program scope, GVL scope, nested UDT members, and array elements. Docs: - docs/Driver.S7.Cli.md — address grammar cheat sheet + the PUT/GET-must- be-enabled gotcha every S7-1200/1500 operator hits. - docs/Driver.TwinCAT.Cli.md — AMS router prerequisite (XAR / standalone Router NuGet / remote AMS route) + per-command examples. Wiring: - ZB.MOM.WW.OtOpcUa.slnx grew 4 entries (2 src + 2 tests). Full-solution build clean. Both --help outputs verified end-to-end. Driver CLI suite complete: 5 CLIs (otopcua-{modbus,abcip,ablegacy,s7,twincat}-cli) sharing a common base + formatter. 122 CLI tests cumulative. Every driver family shipped in v2 now has a shell-level ad-hoc validation tool. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
ff50aac59f | Merge pull request 'Task #250 — AB CIP + AB Legacy test-client CLIs' (#204) from task-250-abcip-ablegacy-cli into v2 | ||
|
|
b2065f8730 |
Task #250 — AB CIP + AB Legacy test-client CLIs
Second + third of the four driver test clients. Both follow the same shape as otopcua-modbus-cli (#249) and consume Driver.Cli.Common for DriverCommandBase + SnapshotFormatter. New projects: - src/ZB.MOM.WW.OtOpcUa.Driver.AbCip.Cli/ — otopcua-abcip-cli. AbCipCommandBase carries gateway (ab://host[:port]/cip-path) + family (ControlLogix/CompactLogix/Micro800/GuardLogix) + timeout. Commands: probe, read, write, subscribe. Value parser covers every AbCipDataType atomic type (Bool, SInt..LInt, USInt..ULInt, Real, LReal, String, Dt); Structure writes refused as out-of-scope for the CLI. - src/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Cli/ — otopcua-ablegacy-cli. AbLegacyCommandBase carries gateway + plc-type (Slc500/MicroLogix/Plc5/ LogixPccc) + timeout. Commands: probe (default address N7:0), read, write, subscribe. Value parser covers Bit, Int, Long, Float, AnalogInt, String, and the three sub-element types (TimerElement / CounterElement / ControlElement all land on int32 at the wire). Tests (35 new, 73 cumulative across the driver CLI family): - AB CIP: 17 tests — ParseValue happy-paths for every Logix atomic type, failure cases (non-numeric / bool garbage), tag-name synthesis. - AB Legacy: 18 tests — ParseValue coverage (Bit / Int / AnalogInt / Long / Float / String / sub-elements), PCCC address round-trip in tag names including bit-within-word + sub-element syntax. Docs: - docs/Driver.AbCip.Cli.md — family ↔ CIP-path cheat sheet + examples per command + typical workflows. - docs/Driver.AbLegacy.Cli.md — PCCC address primer (file letters → CLI --type) + known ab_server upstream gap cross-ref to #224 close-out. Wiring: - ZB.MOM.WW.OtOpcUa.slnx grew 4 entries (2 src + 2 tests). Full-solution build clean. `otopcua-abcip-cli --help` + `otopcua-ablegacy-cli --help` verified end-to-end. Next up (#251): S7 + TwinCAT CLIs, same pattern. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
9020b5854c | Merge pull request 'Task #249 — Driver test-client CLIs: shared lib + Modbus CLI first' (#203) from task-249-driver-cli-common-modbus into v2 | ||
|
|
5dac2e9375 |
Task #249 — Driver test-client CLIs: shared lib + Modbus CLI first
Mirrors the v1 otopcua-cli value prop (ad-hoc shell-level PLC validation) for
the Modbus-TCP driver, and lays down the shared scaffolding that AB CIP, AB
Legacy, S7, and TwinCAT CLIs will build on.
New projects:
- src/ZB.MOM.WW.OtOpcUa.Driver.Cli.Common/ — DriverCommandBase (verbose
flag + Serilog config) + SnapshotFormatter (single-tag + table +
write-result renders with invariant-culture value formatting + OPC UA
status-code shortnames + UTC-normalised timestamps).
- src/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Cli/ — otopcua-modbus-cli executable.
Commands: probe, read, write, subscribe. ModbusCommandBase carries the
host/port/unit-id flags + builds ModbusDriverOptions with Probe.Enabled
=false (CLI runs are one-shot; driver-internal keep-alive would race).
Commands + coverage:
- probe single FC03 + GetHealth() + pretty-print
- read region × address × type synth into one driver tag
- write same shape + --value parsed per --type
- subscribe polled-subscription stream until Ctrl+C
Tests (38 total):
- 16 SnapshotFormatterTests covering: status-code shortnames, unknown
codes fall back to hex, null value + timestamp placeholders, bool
lowercase, float invariant culture, string quoting, write-result shape,
aligned table columns, mismatched-length rejection, UTC normalisation.
- 22 Modbus CLI tests:
· ReadCommandTests.SynthesiseTagName (5 theory cases)
· WriteCommandParseValueTests (17 cases: bool aliases, unknown rejected,
Int16 bounds, UInt16/Bcd16 type, Float32/64 invariant culture,
String passthrough, BitInRegister, Int32 MinValue, non-numeric reject)
Wiring:
- ZB.MOM.WW.OtOpcUa.slnx grew 4 entries (2 src + 2 tests).
- docs/Driver.Modbus.Cli.md — operator-facing runbook with examples per
command + output format + typical workflows.
Regression: full-solution build clean; shared-lib tests 16/0, Modbus CLI tests
22/0.
Next up: repeat the pattern for AB CIP (shares ~40% more with Modbus via
libplctag), then AB Legacy, S7, TwinCAT. The shared base stays as-is unless
one of those exposes a gap the Modbus-first pass missed.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|
||
|
|
b644b26310 | Merge pull request 'Task #224 close — AB Legacy PCCC fixture: AB_LEGACY_TRUST_WIRE opt-in' (#202) from task-224-close-ablegacy-fixture into v2 | ||
|
|
012c6a4e7a |
Task #224 close — AB Legacy PCCC fixture: add AB_LEGACY_TRUST_WIRE opt-in for wire-level runs
The ab_server Docker simulator accepts TCP at :44818 when started with
--plc=SLC500 but its PCCC dispatcher is a confirmed upstream gap
(verified 2026-04-21 with --debug=5: zero request logs when libplctag
issues a read, every read surfaces BadCommunicationError 0x80050000).
Previous behavior — when Docker was up, the three smoke tests ran and
all failed on every integration-host run. Noise, not signal.
New behavior — AbLegacyServerFixture gates on a new env var
AB_LEGACY_TRUST_WIRE:
Endpoint reachable? | TRUST_WIRE set? | Result
--------------------+-----------------+------------------------------
No | — | Skip ("not reachable")
Yes | No | Skip ("ab_server PCCC gap")
Yes | 1 / true | Run
The fixture's new skip reason explicitly names the upstream gap + the
resolution paths (upstream bug / RSEmulate golden-box / real hardware
via task #222 lab rig). Operators with a real SLC 5/05 / MicroLogix
1100/1400 / PLC-5 or an Emulate box set AB_LEGACY_ENDPOINT + TRUST_WIRE
and the smoke tests round-trip cleanly.
Updated docs:
- tests/.../Docker/README.md — new env-var table + three-case gate matrix
- Known limitations section refreshed to "confirmed upstream gap"
Verified locally:
- Docker down: 2 skipped.
- Docker up + TRUST_WIRE unset: 2 skipped (upstream-gap message).
- Docker up + TRUST_WIRE=1: 4 run, 4 fail BadCommunicationError (ab_server gap as expected).
- Unit suite: 96 passed / 0 failed (regression-clean).
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|
||
|
|
ae07fea630 | Merge pull request 'Task #242 finish — UnsTab drag-drop interactive E2E tests un-skip + pass' (#201) from task-242-finish-interactive-tests into v2 | ||
|
|
c41831794a |
Task #242 finish — UnsTab drag-drop interactive Playwright E2E tests un-skip + pass
Closes the scope-out left by the #242 partial. Root cause of the blazor.web.js zero-byte response turned out to be two co-operating harness bugs: 1) The static-asset manifest was discoverable but the runtime needs UseStaticWebAssets to be called so the StaticWebAssetsLoader composes a PhysicalFileProvider per ContentRoot declared in staticwebassets.development.json (Admin source wwwroot + obj/compressed + the framework NuGet cache). Without that call MapStaticAssets resolves the route but has no ContentRoot map — so every asset serves zero bytes. 2) The EF InMemory DB name was being re-generated on every DbContext construction (the lambda body called Guid.NewGuid() inline), so the seed scope, Blazor circuit scope, and test-assertion scopes all got separate stores. Capturing the name as a stable string per fixture instance fixes the "cluster not found → page stays at Loading…" symptom. Fixes: - AdminWebAppFactory: * ApplicationName set on WebApplicationOptions so UseStaticWebAssets discovers the manifest. * builder.WebHost.UseStaticWebAssets() wired explicitly (matches what `dotnet run` does via MSBuild targets). * dbName captured once per fixture; the options lambda reads the captured string instead of re-rolling a Guid. - UnsTabDragDropE2ETests: the two [Fact(Skip=...)] tests un-skip. Suite state: 3 passed, 0 skipped, 0 failed. Task #242 closed. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
3e3c7206dd | Merge pull request 'Task #242 partial — UnsTab interactive E2E test bodies + harness upgrades (Skip-guarded)' (#200) from task-242-unstab-interactive-partial into v2 | ||
|
|
4e96f228b2 |
Task #242 partial — UnsTab interactive E2E test bodies + harness upgrades (tests Skip-guarded pending blazor.web.js asset plumbing)
Carries the interactive drag-drop + 409 concurrent-edit test bodies (full Playwright
flows against the real @ondragstart/@ondragover/@ondrop handlers + modal + EF state
round-trip), plus several harness upgrades that push the in-process
WebApplication-based fixture closer to a working Blazor Server circuit. The
interactive tests are marked [Fact(Skip=...)] pending resolution of one remaining
blocker documented in the class docstring.
Harness upgrades (AdminWebAppFactory):
- Environment set to Development so 500s surface exception stacks (rather than
the generic error page) during future diagnosis.
- ContentRootPath pointed at the Admin assembly dir so wwwroot + manifest files
resolve.
- Wired SignalR hubs (/hubs/fleet, /hubs/alerts) so ClusterDetail's HubConnection
negotiation no longer 500s at first render.
- Services property exposed so tests can open scoped DI contexts against the
running host (scheduled peer-edit simulation, post-commit state assertion).
Remaining blocker (reason for Skip):
/_framework/blazor.web.js returns HTTP 200 with a zero-byte body. The asset's
route is declared in OtOpcUa.Admin.staticwebassets.endpoints.json, but the
underlying file is shipped by the framework NuGet package
(Microsoft.AspNetCore.App.Internal.Assets/_framework/blazor.web.js) rather than
copied into the Admin wwwroot. MapStaticAssets can't resolve it without wiring
a composite FileProvider or the WebRootPath machinery. Three viable next-session
approaches listed in the class docstring:
(a) Composite FileProvider mapping /_framework/* → NuGet cache.
(b) Subprocess harness spawning real dotnet run of Admin project with an
InMemory-DB override (closest to production composition).
(c) MSBuild ItemGroup in the test csproj that copies framework files into the
test output + ContentRoot=test assembly dir with UseStaticFiles.
Scaffolding smoke test (Admin_host_serves_HTTP_via_Playwright_scaffolding) stays
green unchanged.
Suite state: 1 passed, 2 skipped, 0 failed.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|
||
|
|
443474f58f | Merge pull request 'Task #220 — Wire FOCAS into DriverFactoryRegistry bootstrap pipeline' (#199) from task-220-focas-factory-registration into v2 | ||
|
|
dfe3731c73 |
Task #220 — Wire FOCAS into DriverFactoryRegistry bootstrap pipeline
Closes the non-hardware gap surfaced in the #220 audit: FOCAS had full Tier-C architecture (Driver.FOCAS + Driver.FOCAS.Host + Driver.FOCAS.Shared, supervisor, post-mortem MMF, NSSM scripts, 239 tests) but no factory registration, so config-DB DriverInstance rows of type "FOCAS" would fail at bootstrap with "unknown driver type". Hardware-gated FwlibHostedBackend (real Fwlib32 P/Invoke inside the Host process) stays deferred under #222 lab-rig. Ships: - FocasDriverFactoryExtensions.Register(registry) mirroring the Galaxy pattern. JSON schema selects backend via "Backend" field: "ipc" (default) — IpcFocasClientFactory → named-pipe FocasIpcClient → Driver.FOCAS.Host process (Tier-C isolation) "fwlib" — direct in-process FwlibFocasClientFactory (P/Invoke) "unimplemented" — UnimplementedFocasClientFactory (fail-fast on use — useful for staging DriverInstance rows pre-Host-deploy) - Devices / Tags / Probe / Timeout / Series feed into FocasDriverOptions. Series validated eagerly at top-level so typos fail at bootstrap, not first read. Tag DataType + Series enum values surface clear errors listing valid options. - Program.cs adds FocasDriverFactoryExtensions.Register alongside Galaxy. - Driver.FOCAS.csproj references Core (for DriverFactoryRegistry). - Server.csproj adds Driver.FOCAS ProjectReference so the factory type is reachable from Program.cs. Tests: 13 new FocasDriverFactoryExtensionsTests covering: registry entry, case-insensitive lookup, ipc backend with full config, ipc defaults, missing PipeName/SharedSecret errors, fwlib backend short-path, unimplemented backend, unknown-backend error, unknown-Series error, tag missing DataType, null/ws args, duplicate-register throws. Regression: 202 FOCAS + 13 FOCAS.Host + 24 FOCAS.Shared + 239 Server all pass. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
6863cc4652 | Merge pull request 'Task #219 follow-up — close AlarmConditionState child-NodeId + Part 9 event-propagation gaps' (#198) from task-219-followup-alarm-wiring into v2 | ||
|
|
8221fac8c1 |
Task #219 follow-up — close AlarmConditionState child-NodeId + event-propagation gaps
PR #197 surfaced two integration-level wiring gaps in DriverNodeManager's MarkAsAlarmCondition path; this commit fixes both and upgrades the integration test to assert them end-to-end. Fix 1 — addressable child nodes: AlarmConditionState inherits ~50 typed children (Severity / Message / ActiveState / AckedState / EnabledState / …). The stack was leaving them with Foundation-namespace NodeIds (type-declaration defaults) or shared ns=0 counter allocations, so client Read on a child returned BadNodeIdUnknown. Pass assignNodeIds=true to alarm.Create, then walk the condition subtree and rewrite each descendant's NodeId symbolically as {condition-full-ref}.{symbolic-path} in the node manager's namespace. Stable, unique, and collision-free across multiple alarm instances in the same driver. Fix 2 — event propagation to Server.EventNotifier: OPC UA Part 9 event propagation relies on the alarm condition being reachable from Objects/Server via HasNotifier. Call CustomNodeManager2.AddRootNotifier(alarm) after registering the condition so subscriptions placed on Server-object EventNotifier receive the ReportEvent calls ConditionSink emits per-transition. Test upgrades in AlarmSubscribeIntegrationTests: - Driver_alarm_transition_updates_server_side_AlarmConditionState_node — now asserts Severity == 700, Message text, and ActiveState.Id == true through the OPC UA client (previously scoped out as BadNodeIdUnknown). - New: Driver_alarm_event_flows_to_client_subscription_on_Server_EventNotifier subscribes an OPC UA event monitor on ObjectIds.Server, fires a driver transition, and waits for the AlarmConditionType event to be delivered, asserting Message + Severity fields. Previously scoped out as "Part 9 event propagation out of reach." Regression checks: 239 server tests pass (+1 new event-subscription test), 195 Core tests pass. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |