Commit Graph

667 Commits

Author SHA1 Message Date
Joseph Doherty f692f6afe4 feat(security): enforce node ACLs on write, alarms and HistoryRead (#520 stage 5)
`Security:Acl:Enabled` (default false) makes scoped `NodeAcl` grants decide
data-plane authorization at the three seams that have one, and gives HistoryRead
a check it never had. Read, Browse and Subscribe stay ungated — stage 6.

The ACL decision REPLACES the server-wide role check rather than chaining with
it. Chained, a grant would have to confer the role as well as pass the scope
check, and only Cluster-scoped grants confer a role — so every narrow grant
would have stayed inert and the flag would have looked inert too. The
load-bearing test is an ALLOW: a session carrying no roles at all writing
successfully on the strength of its grant. A deny-only test passes against a
build where the ACL is never consulted, because the role gate denies too.

Found en route: the principal never reached the session. The authenticator
passed it as OpcUaUserAuthResult.DisplayName, but RoleCarryingUserIdentity
derives DisplayName from the presented token — for a key-bearing client that is
the static username `apikey`, identical fleet-wide. So the trie's matching key
was dropped at the identity boundary, and the audit ClientUserId on a rejected
write recorded `apikey` for every consuming system. Principal and ApiKeyId are
now carried explicitly.

Beyond the stage as sketched:

- Revocation reaches an OPEN session. Every decision re-checks the
  authenticating key against the current snapshot; without it a key revoked by a
  deployment kept its authority until the client chose to reconnect, which for a
  machine-to-machine consumer can be indefinitely.
- UserAuthorizationState is built per CALL, not per session. The per-session
  shape exists so an LDAP session can re-resolve membership that changed out of
  band; nothing can change out of band under API keys, so the generation stamp is
  the whole invalidation signal and a per-call record picks it up for free.
  IsStale/NeedsRefresh therefore cannot fire here and are documented as vestigial.
- The trie is built inside DataPlaneAuthorityState.Apply, under the same
  generation as the snapshot, rather than by a second wiring at the publish
  actor. An uninstalled trie denies everything — indistinguishable from working
  enforcement. Deleting the install turns 13 of the 22 new tests red.
- The deploy log reports what the BUILD dropped instead of re-deriving it. The
  old count agreed with the builder on one of its four drop reasons; a rule with
  a blank ScopeId, a retired scope kind, or a path not starting at a realm
  vanished with the log reading zero.

Both IApiKeyStore implementations widened to the full grant set. The narrowing
was redundant — ApiKeyInterimRoleMapper applies the same filter itself — and
became a trap once scope was enforced. Pinned by asserting the roles are
unchanged, with the two grants carrying different flags so it cannot pass by
accident.

Falsified by mutation: enforcement never engaging, the write seam ignoring the
ACL, the realm dropped from the scope, the revocation check removed, and the
trie never installed each turn the intended tests red and no others.

Full solution suite green.

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-08-01 05:00:28 -04:00
Joseph Doherty 06c56d7719 fix(cluster,acl): OTOPCUA_ROLES fallback + one string-identity rule (#532, #533)
Two independent defects surfaced in review of #520 stage 3.

#532 — Cluster:Roles had no OTOPCUA_ROLES fallback, despite two doc sites
promising one. A node configured only through the env var — which drives ALL of
Program.cs's conditional wiring, so it reads as the authoritative knob — bound an
empty Roles array and joined the cluster carrying no Akka roles at all. It ran,
served, and logged nothing wrong, while central reported "no driver-role nodes
are Up" and every deployment to it timed out. Not hypothetical: the field fix on
wonder-app-vd03 was to hand-add Cluster__Roles__0/1 to a Windows service's
registry environment. Anyone reading the code to diagnose that box would have
concluded from the XML doc that the fallback was already applied.

AddOtOpcUaCluster now post-configures AkkaClusterOptions through the shared
RoleParser.ResolveEffectiveRoles, so BuildClusterOptions (Akka's own member
roles), ClusterRoleInfo, the ControlPlane singleton scope and
ConfigDbApiKeyStore's ClusterId all see one answer. Two sibling validators
(ConfigSource, Telemetry) read Cluster:Roles directly and were exempting the
exact node they exist for — an env-only driver-only node has no ConfigDb and
could sit on ConfigSource:Mode=Direct unchallenged. They resolve the same way now.

Also collapsed the four open-coded `Roles.FirstOrDefault(IsClusterRole)` +
ClusterIdFromRole copies into RoleParser.ClusterIdFromRoles. They had drifted:
three classified the cluster role ordinally, so a verbatim-bound `Cluster-SITE-A`
yielded a null ClusterId — and a null ClusterId applies NO cluster filter, which
made #528's cross-cluster over-grant guard fail OPEN. IsClusterRole is now
case-insensitive; the ClusterId suffix keeps its authored spelling, because
normalizing it would silently rename the Akka role of a running deployment.

#533 — three string-identity rules in one authorization path. AclScopeRef used
default (ordinal) equality while the trie builder filtered ClusterId and hashed
principals OrdinalIgnoreCase; the deploy gate's cross-cluster check was ordinal
too, which was the worse half — it could reject a whole deploy over a ClusterId
case difference the runtime would have accepted. It only worked because resolver
and builder were handed the same NodeAcl instances.

The rule is now stated once, on AclScopeRef, and applied throughout:
identifiers (ScopeId, ClusterId, Principal) compare OrdinalIgnoreCase; path
segments compare Ordinal. AclScopePathResolver re-keys its own maps rather than
documenting a comparer contract for callers, so the two independent producers —
EF at the gate, artifact JSON on the node — cannot diverge from the outside.
PermissionTrieNode.Children stays Ordinal: those are browse names, and Speed /
speed are two nodes that can coexist under one device.

Split PermissionTrieBuildDiagnosticReason.RetiredScopeKind out of
UnresolvedScope. A legacy FolderSegment row and a typo'd id had the same message
and different remedies.

Falsified: five mutations, each reddening only its own guard — remove the
PostConfigure (3 tests), revert IsClusterRole to ordinal (3), revert AclScopeRef
equality (1), revert the resolver's map comparer (6), revert the gate's
comparisons (2), remove the FolderSegment short-circuit (1).

Test isolation: OTOPCUA_ROLES is process-global and xUnit runs classes in
parallel, so the three validator suites that now resolve effective roles share a
non-parallel collection. Without it, cases passing no roles would intermittently
observe another class's env var.

Full solution build clean; full suite green apart from two pre-existing failures
confirmed identical on 3a6b2a1d (PrimaryGateFailoverTests, and
DriverProbeRegistrationTests expecting 10 probe types where 12 now register)
plus the AbLegacy integration suite, which needs a docker fixture.

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-08-01 01:51:22 -04:00
Joseph Doherty 3a6b2a1daf feat(acl): variable-depth scope model + the scopePaths producer (#520 stage 3)
Makes the /raw device tree addressable by an ACL rule, and builds the
scope-path producer PermissionTrieBuilder has accepted since it was written
but which had no caller anywhere.

The plan for this stage said "add NodeHierarchyKind.Raw, whose path is the
RawPath segments Folder/Driver/Device/TagGroup/Tag". That shape is wrong.
RawFolder.ParentRawFolderId and TagGroup.ParentTagGroupId are both
self-referencing, so folders and tag groups each nest without bound and a real
RawPath is folder…/Driver/Device/group…/Tag. NodeScope was fixed-arity and
PermissionTrie.CollectMatches was five hardcoded steps, so the scope model
could not address a real raw tree at all. NodeScope is now {ClusterId, Kind,
Segments} and the walk is a segment loop. The trie STRUCTURE was already
variable-depth (NodeAclPath.Segments is a list, Children is a recursive
dictionary), so only the walker and the scope record had to change.

Four decisions worth keeping:

- The namespace level became the realm. Level 1 gated on NodeScope.NamespaceId,
  but v3 has no Namespace entity — the snapshot was retired when the address
  space went dual-namespace, and the identifier appears nowhere in production
  outside NodeScope. So the level could only ever fail to match, which silently
  made every sub-cluster grant unreachable while cluster grants kept working.
  It is now a realm token derived from the scope's Kind, not carried on it, so
  the walk and the producer cannot disagree about its spelling.
- Provenance comes from the granting row's own ScopeKind, recorded on TrieGrant
  at build time. Depth-derived provenance could not name a raw level at all,
  since the depth of "Device" varies with folder nesting.
- The trie comparer moved from OrdinalIgnoreCase to Ordinal. Raw sibling-name
  uniqueness is ordinal, so Speed and speed can both exist under one device and
  a grant on either would have matched both.
- The null-scopePaths "deterministic test mode" is deleted. It planted
  unresolvable rows at a direct child of the trie root, a position the walker
  cannot reach, so the grant looked placed and could never match — and every
  test using that mode proved nothing about production placement. scopePaths is
  now required, and a row that does not resolve is dropped with a diagnostic.

A scope resolves to a LIST of paths: a raw tag projected into N equipments is
reachable at N+1 NodeIds and a write through any of them lands on the same
driver reference, so a Tag-scoped grant covering only the raw node would be
bypassable through a UNS one. The lookup is keyed on (ScopeKind, ScopeId), not
ScopeId alone — ScopeId has no FK and no type discriminator, so an id collision
across entity types would hand a grant the wrong node's paths.

Also closed here, all found by review rather than asked for:

- NodeAcl rows had no deploy-time validation of any kind and were not reachable
  from DraftValidator at all (DraftSnapshot carried no NodeAcls). They are now
  gated for dangling ids, cross-cluster scopes, blank/contradictory ScopeId, the
  retired FolderSegment kind, and undefined ordinals.
- ConfigDbApiKeyStore conferred roles from Cluster-scoped grants authored in ANY
  cluster, because it filtered on scope kind with no ClusterId predicate while
  ArtifactApiKeyStore read an already-cluster-filtered snapshot. On a fused
  admin+driver node that was a cross-cluster over-grant. Its doc comment claimed
  the two stores matched.
- The two AdminUI ACL banners still said enforcement was LDAP-group -> role
  mapping, which stages 1/2 made false in both directions.
- The /apikeys page was never classified in PageAuthorizationGuardTests, so that
  test has been red since the key-minting commit merged — I did not run
  AdminUI.Tests before merging stage 4.

Falsified rather than assumed: 8 mutations against the trie tests, 5 against the
deploy gate (including one proving a cross-cluster row is not silently
mis-diagnosed as unresolved), a staged red->green for the over-grant regression,
and the realm gate, the comparer and the malformed-path guard each broken
individually to confirm only their own tests go red.

Node ACLs are still not ENFORCED — nothing constructs a NodeScope or calls the
evaluator yet. That is stages 5 and 6; this stage makes the model able to
express what those will enforce.

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-08-01 01:07:59 -04:00
Joseph Doherty a438ac1640 feat(acl): keys + ACLs reach driver-only nodes via the artifact (#520 stage 4)
A driver-only node has had no ConfigDb since per-cluster mesh Phase 4, so it
registered NullOpcUaUserAuthenticator and denied every UserName token. Its keys
now ride the deployment artifact instead.

- ConfigComposer snapshots ApiKeys alongside the NodeAcls it already carried.
  Only the peppered HMAC ships, never a secret, and the pepper is node config
  that is deliberately not in the artifact.
- DeploymentArtifact.ParseDataPlaneAuthority decodes both node-side. Grants are
  scoped to the node's own cluster; keys are not, because ApiKey carries no
  ClusterId — a key is a fleet-wide credential and the ACL rows are what bind it.
- OpcUaPublishActor installs them on DataPlaneAuthorityState on every apply,
  BEFORE its plan.IsEmpty early-return: an artifact that only revokes a key
  produces an empty address-space plan, so feeding after that return would leave
  the revoked key working until an unrelated structural change redeployed.
- ArtifactApiKeyStore serves them to session activation; a node with a ConfigDb
  keeps ConfigDbApiKeyStore, whose per-request read is what makes revocation
  immediate there.
- OtOpcUaNodeManager gains DataPlaneAuthority — the cluster identity blocker #4
  named. NodeScope.ClusterId is required and the evaluator fails closed on a
  mismatch, so until now no scope it built could have evaluated. Nothing reads it
  until stages 5/6.

The generation is a node-local COUNTER driven by the RevisionHash, not derived
from its bits. PermissionTrieCache treats the highest GenerationId as current, so
a generation taken from hash bytes would install a lower number about half the
time and the cache would go on serving the previous deployment's ACLs, silently.

Sessions are not stamped with it yet — that belongs with the first seam that
reads a UserAuthorizationState, in stage 5, rather than being built now and
consulted by nothing.

Live-gated on docker-dev against site-a-1 (driver-only, no ConfigDb): key
authenticates, wrong secret denied, both halves of the revocation asymmetry
observed, and a SITE-A grant confirmed not to reach site-b-1. Key minted with an
independent Python HMAC so the verifier was checked against something other than
itself. Rig left clean.

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-07-31 14:37:18 -04:00
Joseph Doherty dd939d3c97 feat(acl): anonymous becomes a normal grantable principal (#520 D3)
Anonymous sessions used to short-circuit in HandleImpersonation — "let the SDK's
default validation stand" — so they always connected and always carried no roles.
Now admission and authority are separated:

  admission  -> OpcUa:AllowAnonymous, the HOST's decision (it owns token policies)
  authority  -> the authenticator, resolving the reserved principal "anonymous"
                through the SAME grant path a key's principal goes through

So anonymous can be granted WRITE, not merely tolerated as read-only, and it
arrives at the downstream gates as the same RoleCarryingUserIdentity a key
produces — which is the real payoff: no gate carries an anonymous-shaped branch,
so there is no bypass path to get wrong.

AllowAnonymous defaults to TRUE on purpose. Defaulting it false would silently
deny every client without a key the moment this deploys, including ScadaBridge's
Data Connection Layer in another repo. Making keys mandatory is a rollout
decision, not an upgrade side effect. When false, the Anonymous token policy is
withheld so a client is refused at DISCOVERY rather than only at activation, and
activation is rejected independently in case a client attempts a token type the
endpoint never advertised.

Two fail-closed choices, both falsified:
- A failure to read anonymous's grants DENIES rather than admitting with no
  roles. Admitting is the pre-#520 behaviour, and defaulting to it exactly when
  the server cannot determine what anonymous may do stops being harmless once
  reads are gated. Making it admit reds Anonymous_denies_when_grants_cannot_be_read.
- A key may not authenticate as the reserved "anonymous" principal, or a
  credentialled client silently inherits whatever anonymous was granted.

AuthenticateAnonymousAsync is a DEFAULT interface implementation returning
admit-with-no-roles, i.e. exactly the pre-#520 behaviour, so
NullOpcUaUserAuthenticator and every test double keep working rather than being
forced to reimplement it — important because driver-only nodes run the Null one
and would otherwise black out. Note a default interface method is only reachable
through the interface-typed reference, which is how OpcUaApplicationHost holds it.

An existing test asserted the old fall-through and correctly went red; it is
rewritten to pin the new contract rather than deleted, with the reason recorded.

OpcUaServer 366, Host 42 green.

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-07-31 13:20:14 -04:00
Joseph Doherty 65fda7237f refactor(acl): delete the LDAP data-plane authenticator and its tests (#520)
Stage 2b. LdapOpcUaUserAuthenticator was left registered nowhere by stage 2a;
this removes it, its three test files, and the config surface that existed only
to serve it.

Deleted: LdapOpcUaUserAuthenticator, LdapOpcUaUserAuthenticatorTests,
LdapAuthResilienceTests, LdapGlauthOutageLiveTests (19 tests).

Also removed four Security:Ldap keys — AuthTimeoutMs,
MaxConcurrentAuthentications, OutageFailureThreshold, OutageCooldownSeconds —
plus their validator rules and binding/validator test coverage. Verified first
that the ONLY consumers were the deleted class and the validator rules asserting
them; none appear in any checked-in appsettings. Leaving them would have created
exactly the dead-config surface #521/#524/#525 were filed to clear up.

Worth stating why that resilience machinery does not need relocating rather than
just deleting. It existed because the OPC UA SDK raises impersonation
SYNCHRONOUSLY under a SessionManager-wide event lock, so a hung LDAP bind there
serialized every session activation server-wide — Anonymous and X509 included.
Key verification is one indexed lookup plus one HMAC with no network I/O, so the
hazard the wall-clock bound, concurrency cap and outage circuit guarded against
no longer exists on that path. LDAP now runs only on AdminUI login, an ordinary
async request path where a slow directory affects the one request making it.

ConnectionTimeoutMs is RETAINED: it is projected into the shared library and is
not authenticator-specific.

Docs corrected rather than left to rot:
- CLAUDE.md's "LDAP Authentication" section described the deleted file as the
  data-plane authenticator. Rewritten, including a warning not to "restore" it on
  seeing the LDAP wiring that AdminUI legitimately still needs.
- infra/README §5b (the GLAuth outage live gate) marked RETIRED with the reason,
  rather than silently dropped — the harness GLAuth is still used by
  OTOPCUA_HARNESS_USE_LDAP=1 and is unaffected.
- docs/security.md's five-key resilience table cut to the one surviving key, and
  a new API-key identity section added.
Historical archreview/ records are left as-is; they are dated accounts.

Host.IntegrationTests 211 tests (was 230, i.e. exactly the 19 removed) with the
same 3 pre-existing failures verified against clean master. Host 37, Security 89.

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-07-31 13:08:50 -04:00
Joseph Doherty f88eb49bd1 feat(acl): ApiKey entity + key format, and put Core on the server's graph (#520)
Stage 1b. Still no enforcement wired — this adds the credential model the
identity cutover (stage 2) will read.

ApiKey holds one principal per key, deliberately. The reason to separate keys
from principals is so many keys share a grant set and rotating a key never
touches an ACL row, and that holds with one principal per key since nothing stops
two keys naming the same principal. A key belonging to several principals at once
buys little and costs a join table. UserAuthorizationState.Principals stays a
list, so adding it later needs no ACL-side change.

ApiKeySecret is the security-critical half and is pure, so it is tested on its
own: otua_<keyId>_<secret>, peppered HMAC-SHA256, FixedTimeEquals. Notes why a
plain HMAC rather than an iterated KDF (the secret is 32 bytes of CSPRNG, and the
call runs inline on session activation, which the SDK serializes server-wide
behind its SessionManager event lock), and fails closed on an unset pepper rather
than hashing under an empty key.

Found and fixed a bug in my own first draft: the key id was url-safe base64,
whose alphabet maps '/' to '_' — the very character TryParse splits on. Roughly
one key in five would have had its id truncated at a random position, an
intermittent auth failure reproducing only for SOME keys. The id is hex now, and
the guard is falsified: reverting the alphabet reds both
The_generated_key_id_never_contains_the_separator and, as a bonus signal,
Two_generated_keys_never_collide, because truncated ids collide.

ApiKeyId is NOT NULL, unlike the nullable NodeAclId precedent whose filtered
unique index would admit two NULL ids. Fine for a config row, not for a
credentials lookup key.

OpcUaServer.csproj now references Core. Until now it did not, so
IPermissionEvaluator was literally uncallable from the node manager — the place
enforcement has to happen. No new transitive package surface.

Schema doc updated for both, and its NodeAcl block flagged for pre-existing drift
(it still documents the GenerationId column v3 dropped) without fixing it here.

Core 247, OpcUaServer 364, Configuration 128 — all green.

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-07-31 12:27:28 -04:00
Joseph Doherty 804c32e5c0 docs(acl): design for API-key identity + node ACL enforcement (#520)
Owner decisions 2026-07-31: the OPC UA data plane is machine-to-machine, so
identity is an API key with a static username rather than an LDAP user; LDAP is
replaced entirely on the data plane (AdminUI login keeps its own); and Anonymous
becomes a normal grantable principal behind an enable setting rather than a
special case in the evaluator.

Re-verified all six of #520's claims on master first — they still hold.

The identity decision dissolves blocker #2 (session carries roles, not groups)
rather than solving it. Blocker #1 (raw-realm nodes have no representable
NodeScope) turns out to be tractable: NodeAclScopeKind already carries Namespace
and FolderSegment, so adding NodeHierarchyKind.Raw over the RawPath segments
makes FolderSegment matchable for the first time.

Seam survey corrects #520 in both directions: HistoryRead already has four
overrides to hang a check on, but Read/Browse/Subscribe genuinely have none and
sit on the hot publish path, so decisions must be cached per session+node.

Records two things the issue did not: enforcement ships behind a default-off
Security:Acl:Enabled dark switch (otherwise the first deploy silently denies
ScadaBridge, which consumes this address space from another repo), and because
Phase 4 leaves driver-only nodes with no ConfigDb, keys ride the deployment
artifact — so key revocation requires a deploy.

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-07-31 12:12:35 -04:00
Joseph Doherty be3152e184 docs(raw): record that a raw rename rebinds live — #489 closed as fixed-by-#516
Re-ran #489's own repro recipe on docker-dev. It does not reproduce: renaming
pymodbus/plc/HR200X -> HR200Z and deploying (no node restart, container at 0
restarts) yields the new raw NodeId serving live ~1 Hz data, the old NodeId gone
with BadNodeIdUnknown, and the UNS projection still Good.

The mechanism is NOT the ApplyDelta/ReinitializeAsync chain the issue's
2026-07-26 code-trace predicted. The node log shows a stop-and-respawn:

    DriverHost: stopped driver child MAIN-modbus
    DriverHost: spawned Modbus driver MAIN-modbus (stub=False)
    DriverInstance MAIN-modbus: subscribed to 2 refs (poll-sub-1)

#516 moved a DriverConfig change out of toDelta and into toStop+toSpawn so the
factory is the single parse authority. A rename changes the merged DriverConfig,
so the child is rebuilt against the new RawPaths and re-subscribes on the same
deploy. #489 was fixed as a side effect and needs no code change.

Also gated the sibling case the issue did not cover: renaming the *device*
(the middle RawPath segment, plc -> plcz) rebinds identically.

Records the operator-facing fact in docs/Raw.md, including the flip side #516
accepts — a rename reconnects the driver, briefly dropping every tag on it.

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-07-31 12:00:17 -04:00
Joseph Doherty 5a7a08deca fix(drivers): detect mid-run comms loss and recover from it (#527)
DriverInstanceActor.DisconnectObserved had no production sender. The only paths
into Reconnecting were a failed *initial* connect and an operator's Force
Reconnect, so a driver that connected and then lost its device stayed Connected
indefinitely: publishing Bad for every tag, never re-initialising, and NOT
recovering when the device returned. PublishHealthSnapshot read GetHealth() for
reporting only and never acted on a driver reporting itself unhealthy.

Both comms-loss quality paths -- #477's native-condition annotation and #481's
scripted-alarm input fan-out -- hang off ConnectivityChanged, so both were
correctly wired to a signal that never fired.

The Connected health tick now evaluates a watchdog and self-sends
DisconnectObserved when the driver reports a non-Healthy state AND its
LastSuccessfulRead has been frozen for DefaultCommsLossTimeout (90s).

The conjunction is the design, and the issue's own proposal -- "non-Healthy for
N consecutive polls" -- is wrong. Degraded means *connected but some data is
bad*; several drivers write health per tag inside the read loop
(ModbusDriver.ReadAsync), so one unreadable address latches Degraded forever
against a perfectly reachable device, and a state-only watchdog would reconnect
that driver every 90s indefinitely -- worse than the bug. LastSuccessfulRead is
the honest evidence: preserved across Degraded/Faulted writes, advanced by any
success. The state check remains the second conjunct so an idle Healthy driver
with nothing subscribed is not declared dead for not reading.

Verified across all 12 drivers that a sustained failure does reach a non-Healthy
state -- nine poll drivers via Degraded, MQTT via live connection state, Galaxy
via its reconnect supervisor. CalculationDriver reports Healthy while running
and so can never trip, which is correct: it has no transport.

Also: the Reconnecting retry now calls ShutdownAsync before InitializeAsync.
ModbusDriver (_transport) and MqttDriver (_connection) overwrite an
IAsyncDisposable field inside InitializeAsync without disposing the previous
one, so re-initialising without a teardown leaks a socket per attempt -- latent
while only a manual Force Reconnect reached this path, but the watchdog makes it
automatic and unbounded (~360 leaks for an hour-long outage at the 10s retry).

Tests: 8 new in DriverInstanceActorCommsLossWatchdogTests, each absence
assertion carrying a positive control (a proven count of processed health-poll
ticks). Falsified five ways -- dropping either conjunct reds exactly the test
written for it, and removing the teardown, the null baseline, or the watchdog
call each reds its own guard.

Live gate PASSED on docker-dev (Modbus + otopcua-pymodbus-standard), run twice:
  - fixture stopped -> watchdog fires at ~108s, "declaring comms lost"
  - fan-out observed at Debug: "pushed BadNoCommunication for 2 mux ref(s)"
    (#481 Layer 4) and the #477 native-condition annotation on a driver
    owning conditions
  - fixture restarted -> reconnected in ~8s with NO node restart; both the raw
    (ns=2) and UNS (ns=3) NodeIds read Good with fresh timestamps

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-07-31 10:58:38 -04:00
Joseph Doherty 6cd91cc30a docs(alarms): record the #481 live-gate finding — the comms-loss signal never fires (#527)
The docker-dev gate for #481 could not close on its headline scenario, and the
reason is worth recording next to the feature rather than only on the tracker:
DriverInstanceActor.DisconnectObserved has no production sender, so a driver
whose device dies mid-run is never detected. Filed as #527 with the live
evidence (Modbus stayed Connected >10 min publishing Bad, and did not recover
when its fixture returned until the node was restarted).

What the gate DID establish: the change deploys and runs (scripted alarm
materialised on central-1 against the seeded Modbus tag), and the #478 Layer 3
path does carry Bad into scripted input quality for Modbus, because that driver
publishes Bad per tag rather than going silent.

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-07-31 09:54:47 -04:00
Joseph Doherty c81cef39f5 feat(alarms): bridge driver comms-loss into scripted-alarm input quality (#481)
Layer 4 of the condition-Quality chain (#477 -> #478). #478 gave a scripted
condition the worst quality of its input tags, but only for inputs whose driver
PUBLISHES a Bad data change. A poll driver whose device goes unreachable
publishes nothing — it raises ConnectivityChanged(false) and goes silent — so
the engine held its last Good value, WorstInputStatus stayed Good, and worse,
AreInputsReady stayed true, so the predicate went on evaluating a stale value
after the source had died.

`DriverHostActor.FanCommsLossToDependencyMux` pushes a synthetic
BadNoCommunication with a null value into the dependency mux for every value ref
the disconnected driver owns.

The issue asked for a driver -> all-tag-refs map to be built for this. It
already exists: `_nodeIdByDriverRef`, keyed (DriverInstanceId, RawPath) and
rebuilt from the composition on every apply. Alarm-bearing tags live in the
separate `_alarmNodeIdByDriverRef` and are deliberately excluded — a native
condition is not a mux value and takes the Part 9 quality path instead.

Nothing is pushed on reconnect, deliberately: publishing Good would assert a
value quality this actor has not observed. Recovery rides the driver's own
republish, and the mechanism was verified rather than assumed — the
Connected -> Reconnecting edge calls DetachSubscription, which nulls the
subscription handle, so the reconnect's ResubscribeDesired builds a FRESH
subscription whose PollGroupEngine initial push runs with forceRaise: true.
Without that detach the poll engine would compare against its retained
LastValues, see an unchanged value, raise nothing, and strand these refs Bad
forever — the value-dedup trap that bit the v3 Batch 4 virtual-tag reassert.

Closes #478 Finding 3, which the above depends on. WorstInputStatus skipped
every input whose VALUE was null as "no data yet" — and Bad-with-no-value is
exactly the shape a comms-lost driver produces, so the skip was hiding the case
that matters most; without this half the fan-out above would be silently inert.
The upstream source now stamps a never-pushed path BadWaitingForInitialData —
the honest Part 4 code for that state — and the engine skips that specific code
rather than every null value.

Deleting the null-skip outright is the obvious fix and is wrong in the other
direction: it makes every not-yet-published input drag its condition Bad at
deploy, flooding the quality path with load-time annotations, which is what the
skip existed to prevent. Both mistakes are pinned by a test pair that goes red
under the opposite error, and both were falsified by reverting the production
code:

  old null-skip restored     -> A_pushed_Bad_carrying_no_value      RED
  null-skip deleted outright -> An_input_that_was_never_pushed      RED
  fan-out call removed       -> the three DriverHostActor tests     RED (1 of 7)

The never-pushed test was vacuous on first writing and is worth recording: the
quality bucket only emits on CHANGE, so the load-time evaluation is the one that
flashes Bad, and subscribing to OnEvent after LoadAsync made the assertion
unfalsifiable — it passed against the broken behaviour. It now subscribes first.

`FakeUpstream.ReadTag` returned 0x80340000 (BadNotConnected) for an unset path,
a different Bad code from production's placeholder. Harmless while any Bad
behaved alike; load-bearing now, so it is aligned and pinned by a reflection
guard asserting the engine's private constant agrees with what the production
source stamps.

Behaviour change to weigh, flagged in the issue and confirmed: virtual tags
computed from a comms-lost input now go Bad too. That follows from using the
shared mux and reads as correct, but it is broader than scripted alarms.

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-07-31 09:21:11 -04:00
Joseph Doherty b815446940 refactor(drivers): delete GetMemoryFootprint / FlushOptionalCachesAsync (#525)
Both `IDriver` members had no production call site. Their only consumer was
`MemoryTracking`, deleted with the driver-tier recycle machinery in #522, and
`GetMemoryFootprint`'s doc-comment claimed "polled every 30s by Core" — which
had not been true since v3, even before #522 removed the poller.

Owner decision on #525 was (a) delete rather than (b) build the process-wide
watchdog that would consume them. The driver-side implementations are in git
history and were mostly reusable; what was always missing is the trigger, and a
member nobody calls is how the misleading doc-comment survived this long.

Removed from `IDriver`, all 12 driver implementations, and every test stub —
plus the support code that existed only to feed them, which is the part a
member-only deletion would have left behind as dead weight:

- MTConnect's three per-entry byte-weight constants, its cached
  `ProbeModelDataItemCount`, and `CountDataItems` — a full device-tree walk run
  on every cache fill to populate a number with no remaining reader.
- OpcUaClient's `_discoveredNodeCount` field and the discovery-pass write to it.
- MQTT's `ApproxBytesPerAuthoredTag`.

Two behavioural notes, neither a change in what the software does:

- `AbCipTemplateCache` now has no production reset path. Its only caller was
  AB CIP's flush, which itself had no caller — so nothing changes except how
  visible the fact is. Recorded on the type, along with the correction that its
  comment's claim about a device `ReinitializeAsync` also flushing it was never
  true. A UDT redefined on a live controller keeps its stale shape until the
  driver instance is rebuilt.
- MTConnect's `/probe` cache is still dropped, by `InvalidateProbeModel()` on an
  Agent restart. That is now `internal` rather than `private` so the tests which
  used the flush purely to empty the cache drive the real path instead — they
  now cover a case that actually occurs in production. Several unrelated doc
  comments cited `FlushOptionalCachesAsync` as the canonical CAS example and are
  repointed to it.

Tests: the ones that existed only to assert on the removed members are deleted
(3 OpcUaClient, 3 Galaxy, 2 MQTT, 1 MTConnect, 1 AbCip). Worth noting one was
vacuous — `FlushOptionalCachesAsync_resets_footprint_counter` asserted a
footprint of 0 before the flush and 0 after with no discovery in between, so it
would have passed against a flush that did nothing at all.

Full suite green except 7 failures verified identical on master before and
after (4 AbLegacy integration with the compose profile down, 3
Host.IntegrationTests), checked by name rather than assumed.

Docs corrected where they described this as live: `DriverLifecycle.md` (which
carried the #525 placeholder), `drivers/AbCip.md`, `drivers/AbLegacy.md`, and
`v2/driver-stability.md` — whose "polls this every 30 s" + per-driver
`DriverConfig` memory budget were never built as written and are now banner-ed
as design intent rather than description.

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-07-31 09:07:11 -04:00
Joseph Doherty 803f4e6efe refactor(sql): split ISqlDialect/SqlServerDialect into a .Dialect leaf (#526)
`Driver.Sql.Browser` referenced the runtime `Driver.Sql` project. The AdminUI
references that browser, so the whole SQL driver runtime — and
`ZB.MOM.WW.OtOpcUa.Core` through it — sat in the AdminUI's build/deploy graph.
This is the same layering violation #512 removed from the MQTT browser, in a
second driver, and it is why #512's expected removal of `Core.dll` from the
AdminUI's output did not happen.

MEASURED, both directions, on a clean AdminUI build:

  before: ZB.MOM.WW.OtOpcUa.Core.dll + ZB.MOM.WW.OtOpcUa.Driver.Sql.dll present
  after:  both absent

The old csproj comment's premise was sound and survives — the dialect's catalog
SQL *is* the browse engine, so it must be shared rather than duplicated. What
was wrong was the conclusion that sharing it required referencing the runtime
driver. `ISqlDialect`/`SqlServerDialect` depend on nothing in `Driver.Sql`, so
they move to a `.Dialect` leaf that both consume.

This is the `.Transport` shape, not the cheap one: `ISqlDialect` exposes
`DbProviderFactory` and `SqlServerDialect` returns `SqlClientFactory.Instance`,
so `.Contracts` (deliberately provider-free) cannot hold them. Assembly name is
`.Dialect`; the NAMESPACE stays `ZB.MOM.WW.OtOpcUa.Driver.Sql`, matching the
`Driver.Mqtt.Transport` precedent — the extraction cost zero `using` changes.

Two dependencies the cut edge surfaced as the implicit ones they were:

- The AdminUI itself read `SqlDriver.DriverTypeName` in three places — the tag
  editor map, the tag config validator, and the Sql address picker. All three
  now read `DriverTypeNames.Sql`, which is exactly what that constant resolves
  to and exactly the repoint `SqlDriverBrowser`'s own comment had deferred
  until a factory was registered against the shared constant. One exists now.
- `SqlDriverFormContractTests` asserts the AdminUI form's emitted JSON against
  the runtime factory that reads it, so it genuinely needs the runtime driver.
  `AdminUI.Tests` now references it explicitly. A test project referencing a
  runtime driver is fine — tests are not in the AdminUI's deploy graph.

New guard: `DriverBrowserLayeringTests` (Commons.Tests) scans the csproj graph
of every `*.Browser` project in the tree, transitively. It reads csproj files
rather than loaded assemblies because the cost is a build-graph cost — the
compiler emits no assembly reference for an unused `ProjectReference`, so
`MqttBrowserLayeringTests`' assembly-reference approach cannot see that case.
The two are complementary and each now points at the other.

Falsified three ways, each red then green again: the direct reference re-added
to the browser; the same reference one hop out via `.Dialect` (proving the walk
is really transitive); and both controls — browsers-discovered and
references-parsed — which exist so an empty discovery cannot pass the absence
assertion vacuously.

#526's claim that the reference "carries no comment at all" was wrong; it
carried a detailed one from the scaffold commit. Corrected on the issue and in
the design doc's project table, which had recorded the deviation as deliberate.

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-07-31 08:38:57 -04:00
Joseph Doherty c74ccc55b5 feat(mqtt): flatten Sparkplug Template/DataSet metrics to sibling tags (#515)
`SparkplugCodec` handled scalars; `DataSet`, `Template` and `PropertySet` were skipped
with a warning. They now flatten to addressable tags (owner decision, recorded on the
issue):

  Template  → sibling metrics, `/`-joined, recursively: Motor → Motor/Speed, Motor/Stator/Temp
  DataSet   → one metric per cell, {column}/{rowIndex}: Recipe → Recipe/Step/0, Recipe/Target/1
  PropertySet → node metadata, never tags — it describes a metric rather than being one

Flattening was chosen over OPC UA Structures because flattened scalars are consumable by
any client with no type dictionary, and the result mirrors how the `/raw` tree works.

**The row index is always present, including on row 0.** Emitting a bare column name for
a single-row table and an indexed one otherwise would make a tag's name depend on how many
rows the plant published — a table growing from one row to two would rename every tag
already authored against it.

**A DATA metric carries the parent's alias and no name**, so member names cannot be
composed until the alias table has resolved the parent. Expansion therefore happens in
`SparkplugIngestor.PublishStructuredMembers` — after resolution, at the single funnel both
the DATA and birth-value paths already pass through — not at decode time. The alias table
installs a binding per member so browse enumerates them and a DDATA member that omits its
datatype falls back to the birth's (guessing from the CLR type would read a signed Int32 of
-42 out of its unsigned field as 4294967254).

**Skip-and-warn survives, and refusal is whole** — the explicit requirement on the issue.
A template definition, an unnamed member, an extension value, a column/type mismatch, a
short row, or a payload past MaxDepth(5)/MaxMembers(512) refuses the ENTIRE metric. A
silently half-flattened UDT looks exactly like a complete one in the picker.

The browse picker offers the members and deliberately NOT the structured parent, which has
no value and no servable datatype. The rediscovery signature likewise tracks members rather
than the parent, or a UDT gaining a member would leave the signature unmoved.

Member paths contain `/`, which #509 already solved: the slashed name travels intact as
`metricName` while the derived tag Name is coerced to a legal RawPath segment.

Live-gated 3/3 against the Mosquitto fixture with the project-owned simulator extended to
publish a nested Template and a 2x2 DataSet. Falsified at three points: dropping the member
bindings, not expanding the parent, and refusing to flatten templates each turn exactly the
expected tests red.

Also fixes a regression from the #511 commit in the same branch: `AddOtOpcUaDriverFactories`
resolved `IDriverPrimaryRoleSource` with `GetRequiredService` but only `AddOtOpcUaRuntime`
registered it, so a graph wiring driver factories without the full runtime failed at
resolution. Two Host integration suites do exactly that and caught it; both extensions now
TryAdd the same concrete `RedundancyRoleView`, so the registration is order-independent and
the fail-loud resolve is kept.

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-07-31 08:14:04 -04:00
Joseph Doherty 7f2108dcf2 feat(mqtt): Sparkplug primary-host STATE publishing, Primary-gated (#511)
`ActAsPrimaryHost` was accepted by config and by the AdminUI form and did nothing but
log a warning. It now delivers the whole three-part contract or none of it: a retained
`ONLINE` on `spBv1.0/STATE/{hostId}`, a matching retained `OFFLINE` armed as the MQTT
Last Will, and an explicit `OFFLINE` on a clean stand-down.

**The claim is a dedicated connection, not a message.** A Will can only be registered in
the CONNECT packet — it cannot be added to a live session, changed, or withdrawn. So a
claim that is acquired and released at runtime cannot ride the long-lived ingest session.
`SparkplugPrimaryHost` opens its own connection (client id `{clientId}-spbhost`, forced
clean-session) when the node gains Primary and closes it when the node loses Primary; the
connection's lifetime *is* the claim, so every leg follows from its lifecycle. Ingest is
untouched by a role change — no dropped subscriptions, no lost birth cache, no data gap at
the Secondary->Primary transition.

**Primary-gated** (owner decision, recorded on the issue). Both pair nodes subscribe
independently, so an ungated claim means both claim the same host id — and the sharp
failure is not the two fighting over the retained STATE, it is that the SECONDARY's death
fires its Will and publishes OFFLINE while the Primary is healthy, stopping every edge node
in the group. Registering the Will only on whichever node is Primary at connect time fails
the other way: a node that later gains Primary would publish ONLINE with no Will behind it.

New seam: `IDriverPrimaryRoleSource` (`Core.Abstractions`) carrying the *data-plane* verdict
(`PrimaryGatePolicy.ShouldServiceAsPrimary`), not the alarm-drain verdict — an unknown role
with a driver peer present must deny. Registered unconditionally by `AddOtOpcUaRuntime`,
deliberately NOT alongside `IRedundancyRoleView`, which `AddAlarmHistorian` registers only
when that section is enabled: piggybacking would leave a pair with no alarm historian
falling back to "claim unconditionally". Polled on a 1s timer rather than evented — a
process singleton raising events at per-instance drivers outlives every driver it holds.

Accepted trade: a brief edge-visible OFFLINE window during failover. That is a genuine
state transition, not a glitch to hide.

Live-gated 5/5 against the Mosquitto fixture, including the Will leg — `AbandonForTests`
drops the socket with no DISCONNECT, because a clean disconnect makes the broker discard
the Will by protocol rule, so a test driven through `StopAsync` would observe the
stand-down OFFLINE and pass against an implementation that never armed a Will. Falsified:
removing the Will turns that leg and only that leg red.

Also corrects two stale claims found en route: the AdminUI form still said MQTT tags are
read-only (#508 shipped), and the driver doc still said nothing consumes `IRediscoverable`.

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-07-31 07:17:17 -04:00
Joseph Doherty 72be19225d feat(mqtt): write-through (IWritable) — Plain publish + Sparkplug NCMD/DCMD (#508)
MqttDriver implemented no IWritable, so every MQTT node materialized read-only
regardless of what the operator authored. It now publishes.

  Plain      -> the tag's writeTopic; UTF-8 text (Raw/Scalar) or a bare JSON
                literal (Json)
  Sparkplug  -> DCMD for a device metric, NCMD for an edge-node metric, carrying
                the metric BY NAME with an explicit Datatype and no seq

Both at QoS 0, retain:false. Retain is deliberately not configurable — a retained
command is replayed by the broker on every future subscribe, including the
device's own reconnect, so one stale write would be re-applied forever.

writeTopic is a new, separate TagConfig key, and its ABSENCE is meaningful: the
write is refused BadNotWritable and the node is discovered ViewOnly. The issue's
"do not skip" warning drove the design — the one outcome worse than read-only
nodes is a node that looks writable, returns Good and publishes nothing. Reusing
the read topic would be worse still: it would echo back and read as a confirmed
device value. Browse-time writability is computed by the SAME encoder the write
path uses, so a node cannot advertise writability it would then refuse.

Good means published, not applied — MQTT has no application-level write ack, so
this is Galaxy's optimistic-Good posture and inherits its property: a failed
DEVICE write can never be surfaced. A failed PUBLISH is reported Bad; the
optimism covers what the device did with the command, never whether it was sent.
WriteIdempotent stays default-off.

The encoder is pure and lives in .Contracts, so both wire shapes are testable
without a broker. Unrepresentable values and types with no Sparkplug encoding are
refused rather than coerced — a Reference must not silently become a String on
the wire, and "not-a-number" must not become 0 on a live plant.

LIVE GATE PASSED against the real Mosquitto fixture on 10.100.0.35: 21/21
integration tests, including 6 new ones that observe the published message with
an INDEPENDENT broker subscriber — a fake asserting "publish was called" could
not tell the feature working from the feature publishing to the wrong topic.

The gate earned its keep: the NCMD test initially failed because NCMD is a SHARED
channel — the driver publishes its own rebirth request (Node Control/Rebirth) on
the very topic an edge-node metric write uses, and it arrived first. Correct
driver behaviour, wrong test; the watcher now matches on metric name. Documented,
because anything consuming that topic needs to know. DCMD has no contention.

Offline: 24 encoder + 9 driver tests. The four new status constants are NAMED so
StatusCodeParityTests can see them (#497/#519) — it went 258 -> 262 and validated
each against the pinned SDK.

Also corrects the Mqtt.md "Known gaps" table: prunes the six rows closed in this
round, and fixes the #507 row, which still described rediscovery as inert after
that issue was closed as superseded and its injection path deleted.

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-07-31 06:33:23 -04:00
Joseph Doherty 2d20aeb779 fix(opcua,drivers): carry driver status sub-codes to clients (#519) + health-write ordering (#517)
#519 — a driver's OPC UA status code now reaches a client with its sub-code intact.
DriverInstanceActor projected the driver's uint onto a 3-state Good/Uncertain/Bad enum
and OtOpcUaNodeManager re-expanded Bad to a bare 0x80000000, so BadNoCommunication,
BadTypeMismatch and BadNotSupported were indistinguishable on the wire and every
driver's status constants (incl. the 16 #497 had just corrected) were diagnostic in
logs only. Resolved by option (b): the raw uint rides AttributeValuePublished ->
AttributeValueUpdate -> IOpcUaAddressSpaceSink.WriteValue, OpcUaQuality is deleted, and
severity classification is a helper (OpcUaStatus.IsGood/IsUncertain/IsBad).

The surface was wider than the issue costed (41 files, not "the sink and 3
implementations"): OpcUaQuality had non-driver producers with no uint to carry.
Each got its natural code — BadInternalError for a failed virtual-tag script,
BadNoCommunication for driver comms loss — and ScriptedAlarmHostActor's pair of
mutually-inverse uint<->enum mappers is deleted, having round-tripped a code the
engine already held. AddressSpaceApplier's removal writes deliberately keep the
generic Bad: not losing a code the driver had is this issue; inventing one for the
deploy path is a separate call.

Behaviour change: WriteAlarmQuality fires its Part 9 event on a status-code change
rather than a severity-bucket change. While the annotation was 3-state those were the
same predicate; now a move between two Bad reasons changes what a subscriber reads.

New SDK-free named constants live on Commons.OpcUa.OpcUaStatus, and
StatusCodeParityTests is widened to cover them — that guard is reflection-driven, so
it can only see a named constant, never an inline literal.

#517 — the symptom is real but the issue named the wrong path and its fix was unsafe.
ShutdownAsync cannot race: DriverInstanceActor calls it from PostStop, after the
mailbox drains. (Core/Hosting/DriverHost, the one class with a concurrent GetHealth,
has no production call site.) InitializeAsync can: it runs on a fire-and-forget
Task.Run, and MTConnectDriver writes Healthy then starts loops that can throw into a
catch which disposes the client before writing Faulted.

Moving the write earlier, as suggested, inverts the terminal state — teardown drains
in-flight loops that write health as they unwind, so a late loop could leave Healthy at
rest with every connection closed. The fix is a bracket (conservative before, terminal
after), applied to MTConnect's init-failure path only; shutdown keeps its single
trailing write, and the rule plus the reachability table are documented on
IDriver.ShutdownAsync.

CalculationDriver.GetHealth returned a hard-coded Healthy that consulted nothing —
Healthy before initialize, after shutdown and after dispose. Now derived from _running.
Its test, named Health_is_always_Connected, asserted the defect and is replaced.

Every new guard was falsified by breaking the production code and watching it go red.
The two sub-code tests each assert two different Bad codes, since a single-code
assertion could pass against a hard-coded constant under the old projection.

Pre-existing failures, verified unchanged on a stashed tree and not chased: 4 in
Driver.AbLegacy.IntegrationTests (slc500/micrologix/plc5 fixtures not up) and 3 in
Host.IntegrationTests.

Closes #517
Closes #519

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-07-31 05:25:27 -04:00
Joseph Doherty cbb882293b refactor(drivers): delete the inert driver-tier recycle machinery (#522)
The tier system was documented, operator-authorable, and inert. Deleted rather than activated,
because its premise is gone rather than merely unused.

"Tier C" meant a driver running out-of-process behind an IDriverSupervisor that could restart its
Host without tearing down the OPC UA session. No such process exists anywhere: Galaxy reaches
MXAccess over gRPC to the external mxaccessgw sidecar (PR 7.2 retired the in-process
Galaxy.Host/Proxy/Shared projects) and FOCAS has run in-process since its managed wire client
landed 2026-04-24. Consistently, IDriverSupervisor had ZERO implementations and there was nothing
for one to implement against.

The issue understated the inertness. It says the Tier-C-only protections never engaged, implying
the Tier A/B parts did. They did not: nothing constructs MemoryTracking, MemoryRecycle or
ScheduledRecycleScheduler outside their own unit tests, so the whole Core/Stability recycle layer
was dead — meaning option (a), "pass real tiers", was never a flag flip. It would have meant
writing the wiring that never existed AND arming it.

Deleted: MemoryTracking, MemoryRecycle, ScheduledRecycleScheduler, IDriverSupervisor, the
vestigial DriverTypeRegistry (referenced only by its own tests), and the RecycleIntervalSeconds
knob — which the AdminUI let an operator author and the parser validated while it configured
nothing.

DriverTier itself SURVIVES and is load-bearing: DriverResilienceOptions.GetTierDefaults supplies
the real per-capability timeout/retry/breaker policies via DriverFactoryRegistry.GetTier and
DriverCapabilityInvokerFactory. Only the isolation-and-recycle layer above it is gone.

Deliberately NOT deleted:

- WedgeDetector came along in the same directory and is equally dead in production, but it is
  tier-agnostic and is not recycle machinery — it only shares the folder. Restored rather than
  swept up in a decision that was not about it.
- IDriver.GetMemoryFootprint() and FlushOptionalCachesAsync() lose their only consumer here.
  Removing them touches all 12 drivers and every test stub, so they are documented as
  consumerless and filed as #525 instead of buried in this diff.

Compatibility: a deployed ResilienceConfig blob still carrying "recycleIntervalSeconds" parses
cleanly (unknown keys are ignored — guarded by a new test, because a blob that suddenly failed to
parse would fall back to tier defaults and silently discard the operator's real overrides), and
the AdminUI's preserve-unknown-keys bag keeps the key rather than rewriting stored config on an
unrelated edit.

The 01/U-6 knob-inertness guard carried an explicit carve-out admitting RecycleIntervalSeconds was
dormant and out of scope; that carve-out is now gone, so the expected set is literally what the
test's name claims.

Note: Host.IntegrationTests has 2 failures (DriverProbeRegistrationTests.is_idempotent,
PrimaryGateFailoverTests) — verified pre-existing by reproducing both on clean master dc9d947b.

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-07-30 04:44:04 -04:00
Joseph Doherty 30d0697c28 feat(hosts): surface per-host connectivity on /hosts; drop the unwritable table (#521)
`IHostConnectivityProbe` was a dead surface: eleven drivers implement it, `GetHostStatuses()`
had ZERO production call sites, and `OnHostStatusChanged` had no subscriber outside the Galaxy
driver's own aggregator. Per-host connectivity was computed by every driver and read by nobody.

The issue offered "build the publisher or delete it". The publisher as its entity doc described
it — driver nodes upserting `DriverHostStatus` rows — is not buildable: per-cluster mesh Phase 4
gates `AddOtOpcUaConfigDb` on the `admin` role, so a driver-only node has no ConfigDb connection
to write rows with. So the capability is kept and the transport changed.

`DriverHealthChanged.HostStatuses` now carries the probe result to `/hosts` as a Hosts column.
That channel already reached the page, already survives the mesh split via the Phase 5 gRPC
telemetry stream, and already replays a last-value snapshot on re-subscribe — so per-host state
re-primes after a reconnect without a durable store. Both halves of the interface finally do
what they are for: the event triggers a prompt publish, the pull is the source of truth.

The point of the column is the case the driver-level state chip structurally cannot express: a
multi-device driver stays aggregate-Healthy while ONE of its devices is unreachable.

Two traps, both pinned by tests that were falsified against the prod code:

- The host digest MUST be in the publish fingerprint. On a single-host-down transition every
  other fingerprint component is unchanged, so the dedup would swallow exactly the publish
  carrying the news — the trap that already bit the rediscovery signal. Removing it turns the
  guard test red, verified.
- null (no probe) must stay distinct from empty (probe with no hosts). proto3 cannot tell an
  absent repeated field from an empty one, hence the explicit `has_host_statuses` flag;
  collapsing them would render every probe-less driver as one whose devices are all fine.

Dropped: the DriverHostStatus entity, enum, DbSet, model config and table (migration
DropDriverHostStatusTable — empty on every deployment, so the scaffolder's data-loss warning is
moot, and Down() recreates it exactly).

Found en route, NOT fixed here: `DriverInstanceResilienceStatus` is the identical defect — no
writer, no reader, only a DbSet declaration, while the live data rides the
`driver-resilience-status` telemetry channel. Its doc-comment now states that rather than
describing the sampler and AdminUI join that were never built. Filed as #524 rather than widening
this schema change beyond what was asked.

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-07-30 04:21:08 -04:00
Joseph Doherty f3cd685da5 docs(drivers): write the two missing driver guides (Sql, Calculation)
Closes the §7.2 priority-3 item. Sql was a shipped, merged driver with NO
user-facing documentation at all -- only design and plan files, which describe
what was intended rather than what an operator needs to author one.

Sql.md covers: SQL Server as the only constructed provider (the other four
SqlProvider names are reserved, and authoring one fails rather than falling
back), the KeyValue / WideRow tag models with worked TagConfig, Query being
rejected end-to-end, the config table with real defaults read from
SqlDriverOptions, connectionStringRef never carrying credentials into an
artifact, per-source query grouping and its case-sensitive group keys, and the
value-bound-vs-identifier-validated split that makes it injection-safe.

Calculation.md covers: what a pseudo-driver is and why it occupies a driver slot,
a Calculation-vs-VirtualTags decision table (the two are easy to confuse), the
literal-only ctx.GetTag dependency extraction and the runtime-built-path trap,
the two deploy gates, the all-deps-arrived publish gate, and the Good->Bad-once
error semantics.

Two stale claims found by checking against source rather than inheriting them:

  - The driver README's Calculation row still carried G-1 ("no typed config form,
    RunTimeout unauthorable"), fixed on 2026-07-27 by CalculationDriverForm.
  - docs/Raw.md's "one auto-created default Engine device" NEVER SHIPPED. I had
    copied it into the new doc before checking; "Engine" has zero occurrences in
    src/ and nothing special-cases Calculation at device creation. Corrected in
    both files. The config key was also wrong in my first draft: runTimeoutMs, an
    int in milliseconds, not a TimeSpan string -- and it is ignored on reinit
    because the evaluator's timeout is constructor-fixed.

Full solution: 49 suites pass; the 2 failures are the known pre-existing
environment ones (AbLegacy.IntegrationTests docker fixture, Host.IntegrationTests).
OpcUaClient.IntegrationTests, which was silently failing, is now green.

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-07-28 14:40:51 -04:00
Joseph Doherty 4624141a5d test+docs: retire the stale EquipmentTagsDarkBatch4 skips, guard the deploy-time
tag gate, and fix three silently-broken OpcUaClient integration tests

Continues working through deferment.md's remaining items.

SKIPPED TESTS (13 -> 0 for this reason). The skip said "dark until Batch 4";
Batch 4 shipped as v3.0 and RETIRED the equipment-tag path rather than lighting
it, so every one of them was waiting on something that had already happened and
gone the other way. Resolved individually rather than in bulk:
  - REVIVED onto the raw/UNS shape (6): four DriverHostActor primary-gate cases,
    the cluster-scoping rebuild, and the real-SDK dual-namespace materialisation
    E2E. The behaviour never went dark, only the v2 seeding did.
  - FOLDED into a live parity test (3): DeploymentArtifactRawUnsParityTests
    already compared RawTagPlan record-equal and RawTagPlan carries array /
    historize / alarm intent, so widening its corpus by two tags covers what
    three empty placeholder suites had been promising. Those suites are deleted.
  - DELETED (4): subjects genuinely retired -- equipment-namespace EquipmentTags,
    and both dot-joint {{equip}}.X token suites (that resolver was deleted in
    Batch 3; the slash-joint form is covered by DeploymentArtifactEquipRefParityTests).
Falsified, not assumed: removing the seeded UnsTagReference turns two revived
primary-gate tests red; re-homing the SITE-A node to MAIN turns the scoping test
red. Widening a parity corpus also needed direct value assertions -- parity alone
cannot distinguish "both seams right" from "both seams blind".
Runtime.Tests skips 13->3, OpcUaServer.Tests 4->1; all remaining are deliberate
EquipmentDeviceBindingRetired tombstones.

G-7 (deploy-time TagConfig gate). MQTT shipped an Inspect() nobody ever called;
now wired. Replaced the hand-maintained list with a reflection guard, because the
existing test enumerates driver types by hand and so guards renames but can never
notice a gap. NOTE: the first version of that guard was hollow -- it discovered
candidates via GetReferencedAssemblies(), which is circular, since the compiler
elides a reference nothing in the IL uses. Removing MQTT from the map also removed
its Contracts assembly from the manifest, and the guard passed green with the bug
reintroduced. Rewritten to scan the output directory; re-falsified and it now
fails naming MqttTagDefinitionFactory. Residual recorded at the code: Sql,
MTConnect, Calculation and OpcUaClient have no Contracts-side Inspect at all, so
the deploy gate stays weaker than the AdminUI's authoring gate for them.

OPCUACLIENT INTEGRATION TESTS (3 of 4 failing, on master too). Not fixture rot:
the simulator was healthy and Client.CLI read the very same node Good. v3 made the
driver resolve every reference through its authored RawTags table, so a bare
"ns=3;s=StepUp" fails LOCALLY at the resolver with BadNodeIdInvalid and never
reaches the wire -- the tests were exercising the unresolved-reference guard.
Fixed by seeding OpcPlcProfile.RawTags in the deploy artifact's TagConfig shape
and addressing by RawPath. 4/4 pass.

DOCS. Applied the Phase7* -> AddressSpace* rename across the four live docs
(historical bannered files deliberately untouched), resolving the three that are
not renames to their real members. Found en route that the earlier banner pass
missed three files: VirtualTags.md, OpcUaServer.md and ScriptedAlarms.md all
still presented the test-scaffolding GenericDriverNodeManager as the production
dispatch path. All three now carry the correction.

Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
2026-07-28 14:32:13 -04:00
Joseph Doherty 88ce8df099 docs: close the plan-bookkeeping drift and state the tier truth (§8.5, §8.6, #522)
Bookkeeping: 13 .tasks.json files closed — the 8 the audit named, plus
mesh-phase4 (Task 9 landed 3a590a0c), the 4th stillpending phase file, and
historian-tcp-transport closed as OBSOLETE (it targets the retired Wonderware
sidecar; there is no Wonderware backend in the tree). Each carries a
closureNote naming the evidence rather than just a status flip.

11 archreview live gates written back from STATUS.md, which had recorded them
passed since 2026-07-13/15 without ever updating the task files: R2-01 #11,
R2-02 #15/#18, R2-05 T15, R2-06 T12, R2-07 T5/T6/T12/T14, R2-11 T22/T24.

R2-03 and R2-10 were deliberately NOT closed. STATUS.md's headline says "every
Round-2 live gate is now GREEN", but its own per-item detail says R2-03 is
"live-blocked on this data-less rig" and R2-10 verified the pipeline with
"breaker-OPEN state not forced". Both now carry an openNote recording the
actual blocker.

The point of the sweep: ~140 phantom pending tasks are gone, so the genuinely
unexecuted 19-task AdminUI follow-ups plan is now the largest open item in
docs/plans/ instead of being buried under work that shipped months ago.

Tier truth: docs/v2/driver-stability.md now states that its tier table is
aspirational — every driver runs Tier A because no factory passes a tier, so
MemoryRecycle and ScheduledRecycleScheduler have never engaged, and the config
parser validates a RecycleIntervalSeconds that does nothing. It also corrects a
staleness the audit missed: the separate-Windows-service hosting it describes
for Tier C no longer exists (Galaxy moved to the mxaccessgw sidecar in PR 7.2,
FOCAS went in-process with its managed wire client). docs/drivers/README.md
already said Tier A for both, so the two no longer contradict.

No runtime change — enabling recycle on two live drivers wants its own live
gate, not a docs-pass side effect. Keep-or-delete tracked as Gitea #522.
2026-07-27 19:54:41 -04:00
Joseph Doherty adce27e7fa refactor(drivers): delete the dead discovered-node injection path (§8.2, #507)
#507 was filed as "injection inert in v3, re-migrate onto the raw subtree".
Reading it, the retained code is not revivable: it resolves equipment from
EquipmentNode.DriverInstanceId UNION EquipmentTags, and BOTH are structurally
empty in v3 (AddressSpaceComposer always constructs EquipmentNode with a null
DriverInstanceId; DeploymentArtifact hard-codes an empty EquipmentTags set).
Removing the guard would have changed a log line and injected nothing. So it
is deleted rather than fixed, and #507 closes as superseded by /raw
browse-commit.

Removed: HandleDiscoveredNodes, PartitionDiscoveredByDeviceHost,
ShouldWarnPartition, PlansRoutingEqual, ApplyDiscoveredPlansForDriver,
_discoveredByDriver, the redeploy re-inject tail, DiscoveredNodeMapper,
DiscoveredInjection, AddressSpaceApplier.MaterialiseDiscoveredNodes,
OpcUaPublishActor.MaterialiseDiscoveredNodes, and the Runtime-local copies of
CapturingAddressSpaceBuilder/DiscoveredNode.

The connect-time discovery loop goes too (StartDiscovery, RediscoverTick,
HandleRediscoverAsync, DiscoveredNodesReady, TriggerRediscovery). With
injection gone it had no consumer, and leaving it would either dead-letter or
keep browsing real devices up to ~15x per connect to drop the result.
ITagDiscovery itself stays — the /raw browse picker drives it through
Commons/Browsing/DiscoveryDriverBrowser, which never went through the actor,
so the picker is unaffected.

deferment.md §4.4 called the 18 DiscoveryInjectionDormantV3 tests "Real —
blocked on #507". They are not: they assert an equipment-rooted graft
(EquipmentRootNodeId == "EQ-1") that v3 cannot produce, so they could never
have unskipped as written. Deleted along with DiscoveredNodeMapperTests, the
CapturingAddressSpaceBuilder tests, and the MaterialiseDiscoveredNodes tests
in AddressSpaceApplierTests/OpcUaPublishActorTests. Runtime.Tests skipped:
31 -> 13.

IHostConnectivityProbe is deliberately NOT resolved here. GetHostStatuses()
has no production call site and nothing writes a DriverHostStatus row, but the
table was re-created in the v3 initial migration, so deleting on inference
would be wrong. Split to Gitea #521 with both options costed.

CLAUDE.md, docs/drivers/{Galaxy,TwinCAT,MTConnect}.md updated — they described
the seam as dead.

Build clean; Runtime.Tests 476 passed / 13 skipped; OpcUaServer.Tests 362
passed / 4 skipped.
2026-07-27 18:57:09 -04:00
Joseph Doherty 53ede679c3 docs+ui(security): state plainly that node ACLs are not enforced (§8.1, #520)
deferment.md §8.1 asked for a decision: wire IPermissionEvaluator into the node
manager, or say plainly that ACLs are not enforced. Decision: the latter. The
evaluator stays in the tree; #520 tracks the wire-up.

Verifying the claim turned up four things worse than the audit recorded:

- docs/security.md, not ReadWriteOperations.md, was the highest-risk doc. It
  claimed an anonymous session is "default-denie[d] any node a session has no
  ACL grant for". The opposite holds: anonymous can Browse/Read/Subscribe/
  HistoryRead the entire address space, and is refused writes and alarm acks
  only because it carries no roles.
- Three of five documented data-plane role strings do nothing.
  OpcUaDataPlaneRoles declares exactly WriteOperate and AlarmAck; ReadOnly,
  WriteTune and WriteConfigure are compared against nowhere in src/. The doc
  called all five "exact, case-insensitive, and code-true".
- ReadWriteOperations.md was fiction beyond the ACL claims. OnReadValue has
  zero occurrences in src/ — the documented read path did not exist. Reads
  never reach a driver: the node manager is push-model and the SDK serves a
  Read from the cached pushed value. WriteAuthzPolicy, _sourceByFullRef,
  _writeIdempotentByFullRef and IRoleBearer are likewise zero-hit, and
  CapabilityInvoker is not referenced by the OpcUaServer project at all. This
  file is rewritten rather than bannered.
- v2-release-readiness.md claimed a whole enforcement layer shipped —
  FilterBrowseReferences, GateCallMethodRequests, MapCallOperation,
  AuthorizationBootstrap, Node:Authorization:* keys. None exist. Whatever
  landed on the v2 branch did not survive into the shipped tree.

The UI change is the operative one: ClusterAcls.razor and AclEdit.razor now
warn that a grant is saved and shipped in every deployment artifact but never
evaluated, so an operator cannot author a deny rule believing it works.

deferment.md gains a §9 execution log tracking §8 remediation.
2026-07-27 18:36:48 -04:00
Joseph Doherty e08855fb9d docs: source-verified deferment register + correct 17 drifted docs
v2-ci / build (push) Successful in 4m52s
v2-ci / unit-tests (push) Failing after 15m58s
Adds deferment.md — a source-verified inventory of new-driver status, all 17
open issues, in-code deferrals, open live gates and plan bookkeeping. Every
claim was checked against src/ and git, not against documentation.

Headline finding: three subsystems are authored, persisted and shipped but
never executed —
  * Node ACLs: IPermissionEvaluator/TriePermissionEvaluator have zero
    production consumers and OtOpcUaNodeManager never references them, yet
    ClusterAcls.razor authors NodeAcl rows and ConfigComposer.cs:51 ships them
    in every artifact. An authored deny rule has no effect.
  * IRediscoverable / IHostConnectivityProbe raise into the void (#518/#507);
    nothing ever writes a DriverHostStatus row.
  * DriverTypeRegistry is vestigial, so no factory passes a tier and every
    driver runs Tier A with the Tier-C protections dormant.

Also records the Calculation driver as picker-visible but unauthorable
(DriverConfigModal has no case) — the "registered but unauthorable" class
recurring after the Sql picker defect — and notes that no parity test guards
DriverConfigModal/DeviceModal, which is why it survived review.

Documentation corrections (source-verified):
  * ReadWriteOperations.md claimed "a denied read never hits the driver" via
    four types that do not exist in src/. Bannered + struck through; a security
    review reading that page would have concluded a per-node ACL gate exists.
  * CLAUDE.md: the Change Detection sentence was false (DriverHost consumes
    nothing); the mesh Phase 4 and Phase 5 live gates and the auto-down 1-vs-1
    gate had all PASSED; the ScriptedAlarmState table was already dropped.
  * driver-expansion tracking: Modbus RTU and SQL poll are merged, not
    pending — its command table would have made someone rebuild two shipped
    drivers in a fresh worktree.
  * drivers/README.md: dead DriverTypeRegistry paragraph, retired
    SystemPlatform namespace kind, missing Sql + Calculation rows, missing
    Modbus RTU-over-TCP transport.
  * TwinCAT.md/Galaxy.md promised an address-space rebuild that never happens.
  * Historian.md gained the #491 unproven-value-capture pointer.
  * IncrementalSync.md and AddressSpace.md bannered as wholesale v2-era (the
    rewrite is recorded as still owed, not done here); four v2 status docs
    bannered as historical; three wrong-name-for-a-live-type fixes.

Left deliberately untouched: the secrets NoOpSecretReplicator line, which
makes a security claim and needs the real behaviour identified rather than a
rename.
2026-07-27 17:26:20 -04:00
Joseph Doherty 813e445936 test(mtconnect): close live-gate leg 5 — deploy -> OPC UA read/subscribe PASSED
v2-ci / build (pull_request) Successful in 6m48s
v2-ci / unit-tests (pull_request) Failing after 18m6s
Re-ran the gate on the rebased branch against a freshly rebuilt
otopcua-host:mtconnect image, so it exercises the merged code.

The 2026-07-24 blocker (antiforgery cookie collision between the running
otopcua-dev rig on :9200 and the isolated stack on :9220) is sidestepped
rather than worked around: the headless deploy API
(POST /api/deployments + X-Api-Key) is AllowAnonymous().DisableAntiforgery()
by design, so cookie scoping is structurally irrelevant to it. No browser
needed — the recommended recipe for any future isolated-stack gate.

Both deploys sealed (DeploymentStatus.Sealed, FailureReason NULL) with both
MAIN nodes acking. Read + subscribe verified over opc.tcp://localhost:4860
across all three type paths: Float64 SAMPLE (sinusoid), Int64 EVENT
(monotonic), String EVENT (READY -> INTERRUPTED). This closes the last
unproven link — driver seam was already covered by the live integration
suite; leg 5 adds DeploymentArtifact -> address space -> OPC UA publish.

Two findings recorded in the plan:

- A bad authored dataType degrades to exactly ONE skipped tag, loudly
  (per-tag warning naming the expected keys, BadNodeIdUnknown, "every other
  tag is unaffected") while the rest keep streaming — the intended
  fail-isolated behaviour, demonstrated rather than argued. Correcting it
  took effect with no restart, showing MTConnect is not subject to the
  separately-tracked config-edits-discarded defect.

- fixture_asset_changed reading 0x80000000 is NOT an MTConnect defect. The
  driver maps the agent's UNAVAILABLE to BadNoCommunication correctly; the
  shared publish path collapses every status to a 3-state OpcUaQuality enum
  (DriverInstanceActor.QualityFromStatus, statusCode >> 30) and re-expands
  Bad to StatusCodes.Bad (OtOpcUaNodeManager.StatusFromQuality). Deliberate
  per the enum's own doc comment, but the client-visible consequence appears
  undocumented: no driver's Bad/Uncertain sub-code ever reaches a client.
  Tracked separately; out of scope here.

Also records the rebase onto master 123ddc3f and confirms StatusCodeParityTests
now covers 9 MTConnect constants, all passing.
2026-07-27 13:59:26 -04:00
Joseph Doherty 9d430bee62 docs(mtconnect): correct the MaintenanceMode note; record status-code parity pre-verification 2026-07-27 13:59:26 -04:00
Joseph Doherty 1d0989d3b4 test(mtconnect): live gate on an isolated rig — 4/5 legs pass, deploy leg blocked on a cookie collision (Task 21) 2026-07-27 13:59:26 -04:00
Joseph Doherty 71ccccef7c docs(mtconnect): P1 driver guide + tracking-doc update, defer write-back (Task 22)
- docs/drivers/MTConnect.md: getting-started guide for the P1 Agent MVP —
  config keys read off MTConnectDriverOptions/ConfigDto, capability surface,
  RawPath->dataItemId coercion precedence, UNAVAILABLE->BadNoCommunication +
  the rest of the quality-code table, CONDITION-as-String, browse-via-the-
  universal-browser, the fixture recipe (links the existing IntegrationTests
  Docker README instead of duplicating it), and a Known limitations section
  covering the two pre-existing fleet-wide gaps this build surfaced
  (IRediscoverable/IHostConnectivityProbe have no server consumer; no driver
  form blocks Save on validation). Records write-back (MTConnect Interfaces),
  P1.5 (native alarms, TIME_SERIES arrays, EVENT->enum), and P2 (SHDR ingest)
  as deferred per design doc SS3.6/SS9. Documents where the build diverged
  from the design: TrakHound MTConnect.NET was dropped entirely (no XML
  formatter in the pinned packages, no injectable HTTP handler) in favor of
  a hand-rolled System.Xml.Linq client, namespace-agnostic on LocalName.
- docs/drivers/README.md: adds MTConnect to the ground-truth driver table,
  the per-driver doc list, and the fixture coverage-map list.
- docs/plans/2026-07-24-driver-expansion-tracking.md: marks the MTConnect
  Wave-2 row Done (22/23 tasks; Task 21 live gate tracked separately in the
  plan file, not touched here), corrects mtconnect/cppagent -> mtconnect/agent
  in the fixture note, and links the new driver guide.

Deferred-cleanup decision (Task 1 review follow-up): removed
GenerateDocumentationFile/NoWarn CS1591 from Driver.MTConnect.Contracts's
csproj to match all eight sibling .Contracts projects, none of which carry
it. Verified both the Contracts project alone and the full solution still
build clean (0 warnings, 0 errors) with the flags gone — the existing XML
doc comments don't depend on GenerateDocumentationFile to compile.
2026-07-27 13:59:26 -04:00
Joseph Doherty 5ba9f1be6f fix(mtconnect): make a /sample stream end loud, and correct the gap contract (Task 7 review)
Code review of c46540ae approved the framing algorithm but moved the risk
onto the contract around it.

C1 (critical). SampleAsync returned normally on three different events:
EOF, the closing --boundary--, and a response that was not multipart at
all (where it yielded one parsed snapshot and finished). The seam
documents the stream as yielding until ct is cancelled, so a Task 11 pump
written to that contract would silently drop its subscription or hot-loop
reconnecting; the non-multipart leg reported a configuration error as a
healthy finished stream, which is the #485 quiet-successful-termination
shape aimed at the very next task. Every non-cancellation end now throws:
MTConnectStreamEndedException (ConnectionClosed / ClosingBoundary -
transient) or MTConnectStreamNotSupportedException (configuration -
reconnecting reproduces it forever), sharing one catchable base. The
non-multipart body is still parsed first so an Agent's own MTConnectError
text wins, but the document is NOT yielded.

I1. IsSequenceGap moved to IMTConnectAgentClient (static) and its first
parameter is now expectedFrom. The old name and doc were wrong for every
chunk after the first - the correct comparand is the PREVIOUS chunk's
NextSequence, and comparing against the opening "from" argument reports a
gap on every chunk once the ring buffer rolls, i.e. an endless /current
re-baseline storm. Both doc blocks also now record that cppagent answers
from < firstSequence with an OUT_OF_RANGE MTConnectError under HTTP 200,
which surfaces as InvalidDataException and NOT as a gap - so Task 11 must
treat that parse failure as a re-baseline trigger too.

I2. Every multipart test served the whole body from one buffer, so every
framing test completed in a single ReadAsync - the split-boundary path,
the split-header path and the multi-fill loop were correct by inspection
only. A ChunkedStream double (N bytes per read, N = 1/3/7) now drives the
fixtures through a split transport, plus a >16 KB document that forces a
buffer resize. Falsifiability: removing either scan overlap, or
collapsing the fill loop, fails ONLY the new chunked tests.

I3. Disposal mid-enumeration surfaces as OperationCanceledException via
an internal dispose-linked token, not a raw ObjectDisposedException that
Task 9's re-init would inflict on an enumerating pump.

I5. HeartbeatMs, SampleIntervalMs and SampleCount join RequestTimeoutMs
in construction-time positive-value validation. All three reach the query
string and an Agent answers heartbeat=0 with an HTTP-200 MTConnectError
that names no config key.

I4/M2. The no-Content-length framing fallback logs a one-shot warning
(the client takes an optional ILogger); a multipart response with no
boundary parameter fails fast instead of degrading into a watchdog
timeout.

M5/M6. Shared element/attribute reading rules extracted to MTConnectXml;
the probe parser documents why it alone does not trim BOM/whitespace. The
literal U+FEFF in source became a '' escape.

Also, from Task 8: MTConnectObservation gained IsStructured (default
false), set from element.HasElements. A DATA_SET/TABLE observation's
<Entry> children concatenate through element.Value to nonsense ("12" for
two entries) that the index would publish as Good, and only the parser
can tell that apart from a legitimate space-bearing Message. False for
CONDITION observations - their value comes from the element name, so
child content cannot corrupt it.

275/275 green in this suite's own files.
2026-07-27 13:57:46 -04:00
Joseph Doherty cf43f8d0ab feat(mtconnect): current/sample parse + sequence-gap detection (Task 7)
Adds the /current and /sample legs to MTConnectAgentClient:

- MTConnectStreamsParser: hand-rolled System.Xml.Linq parse of an
  MTConnectStreams document into MTConnectStreamsResult. Observations are
  every element child of <Samples>/<Events>/<Condition>, keyed by
  dataItemId (the element NAME is the data item's type in PascalCase, so
  a fixed name set would drop observations). A CONDITION's value is its
  element name, not its text - <Normal/> is empty - and <Unavailable/>
  normalizes onto the same UNAVAILABLE sentinel a Sample/Event carries as
  text, so Task 8's no-comms mapping sees one token. Timestamps are
  normalized to DateTimeKind.Utc explicitly.
- IsSequenceGap(requestedFrom, chunk) => chunk.FirstSequence >
  requestedFrom, so Task 11's pump can re-baseline after a ring-buffer
  overflow. Equality is NOT a gap.
- SampleAsync: ResponseHeadersRead + a hand-rolled
  multipart/x-mixed-replace frame reader (Content-length fast path,
  boundary-scan fallback), bounded by a heartbeat watchdog derived from
  HeartbeatMs so a silent Agent faults instead of wedging the pump - the
  S7 frozen-peer shape (arch-review R2-01). The long poll gets its own
  HttpClient with an infinite Timeout so the unary /probe + /current
  deadline stays bounded.

Task 0 package decision, option (c): both TrakHound PackageReferences and
their PackageVersions are dropped. MTConnectHttpClientStream takes a URL
and dials its own socket (no handler/stream seam, so it cannot serve a
socket-free unit suite), and it emits already-parsed documents through the
formatter lookup Task 6 proved is missing - framing-only reuse was never
actually on offer. The driver now depends on nothing but the BCL. Recorded
in the plan's Task 0 CORRECTION block.

Also folds in two Task 6 review carry-overs: the stale
IMTConnectAgentClient doc comment claiming a TrakHound-backed
implementation, and a probe test constructing a mixed-namespace vendor
extension (<x:Pump> with default-namespace <DataItems> children) that
backs the parser's ignore-the-namespace claim with a test.

187/187 green.
2026-07-27 13:57:46 -04:00
Joseph Doherty d3aaa4a411 docs(mtconnect): correct the Task 0 decision — TrakHound cannot parse XML as pinned 2026-07-27 13:57:28 -04:00
Joseph Doherty 3b92b7cc83 docs(mtconnect): record TrakHound-vs-hand-rolled client decision (Task 0) 2026-07-27 13:57:11 -04:00
Joseph Doherty a0b5095b3b docs(drivers): un-stale the MQTT README rows + track every known gap as an issue
v2-ci / build (push) Successful in 4m41s
v2-ci / unit-tests (push) Failing after 16m11s
The cross-driver README still described MQTT as pre-P2 — "Sparkplug B is P2
(`mode: SparkplugB` is a placeholder)" and "Sparkplug B has no fixture yet (P2)".
Both were false as of the P2 merge (c3a2b0f7): SparkplugB is a fully implemented
mode and the live suite is 15 tests (7 plain + 8 Sparkplug) against a
project-owned C# edge-node simulator. Mqtt.md and the scadaproj index were both
already correct; only this file missed the P2 sweep.

Filed the nine Known-gaps rows as tracking issues and linked them, so the table
stops being the only record of them:

  #507  IRediscoverable is inert in v3 (platform gap — also Galaxy/TwinCAT/AbCip)
  #508  write-through (IWritable) — NCMD/DCMD + plain publish
  #509  a metric name containing '/' cannot be browse-committed
  #510  _canRebirth captured at browse-open — reaped session still draws button
  #511  Sparkplug primary-host STATE publishing (ActAsPrimaryHost)
  #512  .Browser references .Driver — extract the client-options builder
  #513  editor writes a meaningless payloadFormat into a Sparkplug blob
  #514  Request-rebirth unarmable on a plant that birthed before the window
  #515  DataSet / Template / PropertySet metric support

#507 is the one worth reading: it is a v3 platform gap, not an MQTT bug —
DriverHostActor.HandleDiscoveredNodes hard-returns, so every IRediscoverable
driver fires into a void and the edge gaining a point needs a redeploy to show up.

No code change; docs + issue links only.
2026-07-27 13:52:08 -04:00
Joseph Doherty c3a2b0f773 Merge branch 'feat/mqtt-sparkplug-driver'
v2-ci / build (push) Successful in 5m36s
v2-ci / unit-tests (push) Failing after 22m40s
# Conflicts:
#	src/Core/ZB.MOM.WW.OtOpcUa.Core.Abstractions/DriverTypeNames.cs
#	src/Server/ZB.MOM.WW.OtOpcUa.AdminUI/Components/Shared/Drivers/DriverConfigModal.razor
#	src/Server/ZB.MOM.WW.OtOpcUa.AdminUI/EndpointRouteBuilderExtensions.cs
#	src/Server/ZB.MOM.WW.OtOpcUa.AdminUI/Uns/TagEditors/TagConfigEditorMap.cs
#	src/Server/ZB.MOM.WW.OtOpcUa.AdminUI/Uns/TagEditors/TagConfigValidator.cs
#	src/Server/ZB.MOM.WW.OtOpcUa.AdminUI/ZB.MOM.WW.OtOpcUa.AdminUI.csproj
#	src/Server/ZB.MOM.WW.OtOpcUa.Host/Drivers/DriverFactoryBootstrap.cs
2026-07-27 13:31:39 -04:00
Joseph Doherty 0f38f48679 merge: Modbus RTU-over-TCP transport (#495)
Wave 1 of the driver-expansion program. The branch was complete and live-gated but
had never been merged; it sat 15 commits ahead and 50 behind master.

Purely additive behind the existing IModbusTransport seam — the application protocol
(function codes, codecs, planner, coalescing, write path, probe, materialisation,
HistoryRead) is identical across TCP and RTU; only the wire framing differs
([addr][PDU][CRC-16], no MBAP, no TxId). Zero changes to codecs/planner/health.

Selected by a new Transport config field (ModbusTransportMode: Tcp | RtuOverTcp),
routed through ModbusTransportFactory (throws on unknown mode), with the string-enum
guard on options/DTO/factory and a Transport selector on the AdminUI Modbus form.
ModbusSocketLifecycle was extracted from ModbusTcpTransport (behaviour-preserving)
and is composed by both transports.

Descoped by design: direct-serial (System.IO.Ports) and Modbus ASCII — RTU buses are
reached exclusively via a serial->Ethernet gateway. No per-tag config changes; the
existing per-tag UnitId already makes a multi-drop bus work.

Re-validated against current master at merge time (the branch's own gate predates 50
commits of master): no overlapping files, clean merge, solution builds 0 errors, and
Modbus 344/344, Modbus.Addressing 161/161, AdminUI 740/740, Runtime 507/507,
Configuration 131/131 all pass. Confirmed the Transport selector is still reachable
through master's current authoring path (DriverConfigModal -> ModbusDriverForm), so
the branch's live /run gate result still applies.
2026-07-26 10:58:51 -04:00
Joseph Doherty 8b7ea3213d fix(rig,docs): backfill ClusterNode.GrpcPort and document the upgrade step (#493)
`GrpcPort` is a nullable column added by Phase 5. Every insert in the docker-dev
seed is INSERT-if-not-exists — the right shape for a re-runnable seed, but it means
a new nullable column never reaches rows an earlier version of the file created. On
a persisted volume all six rows kept NULL, central found no dial targets, and
`TelemetryDial:Mode=Grpc` connected to nothing. (`AkkaPort` escaped this only
because it is NOT NULL with a default of 4053.)

Seed now backfills `GrpcPort IS NULL AND CreatedBy = 'docker-dev-seed'` to 4056.
NULL only — it must not overwrite a port an operator set deliberately on a
long-lived dev volume, and NULL is the unambiguous "predates the column" marker.

Deliberately NOT doing the suggested EF data migration for real deployments. The
correct value is each node's own `Telemetry:GrpcListenPort`, which is
per-deployment configuration the database cannot derive; a migration could only
invent one, and a WRONG dial target is worse than the NULL the dialer already skips
explicitly with a throttled warning. The rig can be backfilled because there the
port is fixed by docker-compose.yml and therefore actually knowable.

`docs/Telemetry.md` gains an upgrade section stating the prerequisite, the symptoms
(the throttled skip log, LISTEN with no ESTABLISHED, the pill never going live) and
the UPDATE to run before flipping any node to Grpc — plus why there is no migration.
2026-07-26 10:29:51 -04:00
Joseph Doherty 549c656489 fix(alarms): re-assert non-normal scripted-alarm conditions after a (re)load (#487)
A deploy that triggers a FULL address-space rebuild clears `_alarmConditions`
and re-materialises every condition node fresh — inactive, acked, confirmed,
unshelved. The engine reloads its persisted state and re-derives Active from the
predicate, so it ends up correct; but there is no transition to report, so
`LoadAsync` yields `EmissionKind.None` and `OnEngineEmission` drops it. Nothing
writes the node.

Live-reproduced on the docker-dev rig against the pre-fix image: an alarm that
had fired and cleared but was still UNACKNOWLEDGED came back from a rebuild
reporting Acknowledged with Retain=false — so it disappeared from
ConditionRefresh entirely, while the engine still held Unacknowledged. An
operator's outstanding alarm silently vanishes from the alarm list on deploy.

`ScriptedAlarmHostActor.ReassertConditionNodes` closes it. After each load it
reads the new `ScriptedAlarmEngine.GetProjections()` and sends one
`AlarmStateUpdate` per alarm NOT in the Part 9 no-event position.

Load-bearing properties:

- Node-only. It sends `AlarmStateUpdate` and nothing else — never the `alerts`
  topic, never the telemetry hub. `alerts` is the historization path, so a row
  per alarm per deploy would append a duplicate historian/AVEVA record every
  time anyone deploys. This is why it reads a projection rather than re-emitting:
  `ScriptedAlarmProjection` carries no `EmissionKind`, so there is nothing for
  the emission machinery — or a future refactor — to mistake for a transition.
  The issue's sketch said `GetState(alarmId)` + `LoadedAlarmIds`; that alone
  would have clobbered the node's severity and message, so the projection also
  carries the definition's severity, the resolved message template, and the
  last-observed worst-input quality.
- Only non-normal alarms. One in the no-event position already matches what the
  materialise built, so a never-fired alarm stays byte-identical to a deploy
  without this pass (including its Message, which the materialise seeds with the
  display name), and an all-normal deploy writes nothing at all.
- Timestamp is the condition's own `LastTransitionUtc`, not the deploy instant.
- No duplicate Part 9 events: `WriteAlarmCondition`'s delta-gate compares against
  the node's CURRENT state, so a re-assert onto a freshly materialised node is a
  genuine delta (fires once — correct, the rebuild reset what clients see) while
  one onto a surgically-preserved node is suppressed.

Tests: 6 new host tests + 6 new engine tests. Falsifiability checked by
disabling the call — 4 of the 6 host tests go red; the other 2 are absence
guards against an over-broad fix and pass either way by design.

Live gate (docker-dev, central-2, pre-fix image vs. rebuilt image):
- pre-fix: condition absent from ConditionRefresh after a rebuild;
- post-fix: present, Unacknowledged, Retain=True, stamped with its own
  LastTransitionUtc rather than the restart instant;
- /alerts stayed empty across two re-asserts, with the panel proven live by a
  real ACTIVATED transition immediately afterwards — no duplicate history.
2026-07-26 09:06:39 -04:00
Joseph Doherty 4dc2ad8084 feat(sql): implement the design §8.1 catalog identifier-validation gate (#496)
Until now ISqlDialect.QuoteIdentifier was the SOLE defence for authored
table/column names: an identifier went from the TagConfig blob straight into a
command text, bracket-quoted. The residual risk was bounded — a hostile name is
quoted into one nonexistent object, the query fails after the connection opens,
and the tag Bad-codes — but "bounded" is not "filtered", and the design promised
a filter. Both ISqlDialect and SqlServerDialect carried a doc paragraph saying so.

SqlCatalogGate + SqlCatalogLoader now resolve every authored identifier against
the live catalog at Initialize, and REPLACE it with the catalog's own spelling.
The identifier text in an emitted poll query is therefore a string this driver
read back out of ListSchemas/ListTables/ListColumns — not operator input. Quoting
becomes the backstop it was documented to be.

Decisions worth knowing before touching this:

- Substitution, not just validation. Matching is exact-ordinal first, then a
  UNIQUE case-insensitive hit: SQL Server's default collation is CI so case
  variants have always worked, and rejecting them would break valid deployments.
  An ambiguous CI match under a case-sensitive collation is refused rather than
  guessed — picking one would publish another column's data under the operator's
  node, which is worse than rejecting the tag.

- Charset check BEFORE catalog lookup. Each identifier goes through
  QuoteIdentifier for its rejection rules first, so a name carrying a control or
  Unicode format character is rejected WITHOUT its value being echoed into a log
  line (Trojan-Source). A name that passes is safe to render, which is why
  catalog-miss messages do name it — an operator hunting a typo has to see what
  they wrote. Both halves are pinned by tests.

- A rejected tag keeps its node. It is dropped from the POLLED table but stays in
  the AUTHORED table, so it still materializes and reads BadNodeIdUnknown —
  §8.1's specified outcome. My first wiring dropped it from both, which deleted
  the node instead; an existing test (ReinitializeAsync_recoversFromFaulted)
  caught it. A status code can only be published by a node that exists, and a
  missing address-space entry is far harder to diagnose than a Bad quality.

- An unreadable catalog FAULTS Initialize; it does not reject every tag. That is
  the absence of evidence about the tags, not evidence against them — rejecting
  all of them would serve a confidently-empty address space and send the operator
  hunting typos that do not exist. Zero visible schemas is treated the same way,
  because that is exactly what a missing GRANT looks like. Faulting lands
  DriverInstanceActor in Reconnecting with its retry timer running.

- Bounded load: one schema list, one default-schema scalar, then one ListTables
  per distinct authored schema and one ListColumns per distinct authored relation
  — never a full catalog enumeration, and nothing after Initialize. Every
  authored name reaches the catalog queries as a bound @schema/@table parameter,
  so building the allow-list cannot itself be an injection vector.

- ISqlDialect gains DefaultSchemaSql ("SELECT SCHEMA_NAME()"). An unqualified
  `TagValues` must resolve in whatever schema the SERVER reports; hardcoding dbo
  would be a silent lie on any estate that maps service accounts to their own
  default schema. It is a query, not a constant, because the answer is
  per-connection.

- Accepted v1 limitation: a 3-part db.schema.table (or linked-server name)
  addresses a catalog this connection cannot enumerate, so it cannot be
  allow-listed and is rejected with a message pointing at the fix — expose the
  data through a view in the connected database.

VerifyLivenessAsync's wall-clock pattern is extracted to RunBoundedAsync and
reused, so the new I/O gets the same R2-01 / STAB-14 protection rather than a
second hand-rolled copy. (It also fixes a latent bug in the extracted code: the
OperationCanceledException arm detached the wrong task.)

Tests: 24 pure gate tests + 9 end-to-end driver tests against the real SQLite
catalog + 3 new live tests against the real SQL Server on 10.100.0.35 (21 in that
suite now pass, exercising the real SELECT SCHEMA_NAME() + INFORMATION_SCHEMA
path). Verified falsifiable: bypassing the gate turns exactly the three rejection
assertions red and leaves the rest green.

SqlInjectionRegressionTests is deliberately NOT rewritten to expect
BadNodeIdUnknown. It drives SqlPollReader directly, below the gate, and pins the
quoting backstop on its own — defence in depth is only worth the name if each
layer holds independently. Rewriting those assertions would delete the backstop's
only coverage and leave the gate a single point of failure. Its scope note, which
said the gate does not exist, is updated to say why it stays where it is.
2026-07-25 16:07:53 -04:00
Joseph Doherty 1919a8e538 feat(config): reject a persisted Sql connectionString at the deploy gate (#498)
The Sql driver's "a pasted literal connection string is never persisted" guarantee was
enforced only on the READ path: SqlDriverConfigDto has no connectionString property and
UnmappedMemberHandling.Skip drops the key on deserialization. Nothing stopped it being
WRITTEN. Config blobs are schemaless JSON columns and the fallback authoring pattern for
a driver without a typed form is a raw-JSON textarea, so an operator pasting
{"connectionString":"Server=...;Password=..."} would put a live credential in the
ConfigDb — persisted, replicated to every node's artifact cache, readable by anyone with
config access — while the runtime silently ignored it and the driver failed to connect.
Discarding a secret on read is not the same as refusing to store it.

DraftValidator.ValidateSqlConnectionStringNotPersisted fails the deploy
(SqlConnectionStringPersisted) when a Sql-typed driver instance's DriverConfig, or the
DeviceConfig of any device beneath it, carries a top-level connectionString key.

- Both surfaces are checked because DeviceConfig is merged onto DriverConfig before the
  DTO sees it — a credential pasted into the device blob is the identical leak.
- The key is matched case-insensitively: System.Text.Json binds ConnectionString to a
  connectionString property by default, so an ordinal match would leave the obvious
  bypass open.
- Only the top level is scanned; the DTO is flat, so a nested occurrence cannot bind and
  is not the mistake this rule exists to catch.
- The message never echoes the value — validation errors reach the AdminUI, the deploy
  log and the audit trail, and repeating the string there would leak the credential the
  rule is refusing to store. Pinned by a test.
- Malformed/blank/non-object JSON never throws: a parse failure would take down every
  other rule in the same pass.

16 tests. Verified falsifiable — with the rule disabled the 6 positive assertions fail
and the 10 negatives stay green, so none of them passes vacuously.

Design §8.2's "if an inline connectionString is ever permitted (dev convenience only),
the AdminUI redacts it" carve-out is withdrawn in the same change: redaction only hides a
credential that has already been written.

Not covered, and filed as a follow-up: ClusterNode.DriverConfigOverridesJson is a third
persistence surface for a driver config blob, but it is not part of DraftSnapshot, so
this validator cannot see it.
2026-07-25 15:37:48 -04:00
Joseph Doherty b95b99ba8e fix(drivers): correct 16 wrong OPC UA status-code constants + guard them by reflection (#497)
Every value verified against Opc.Ua.StatusCodes in the pinned SDK (1.5.378.106) by
reflection, not by copying siblings. All are client-visible: OPC UA clients branch on
status.

The three named in #497:
  - Historian.Gateway SampleMapper "BadNoData"  0x800E0000 -> 0x809B0000
    (0x800E0000 is BadServerHalted)
  - Galaxy "BadTimeout"                         0x800B0000 -> 0x800A0000
    (0x800B0000 is BadServiceUnsupported)
  - TwinCAT BadTypeMismatch                     0x80730000 -> 0x80740000
    (0x80730000 is BadWriteNotSupported)

BadTypeMismatch was wrong in three MORE drivers the issue did not name — FOCAS,
AbLegacy and AbCip carried the same 0x80730000. Every call site is a
FormatException/InvalidCastException conversion failure, so the name was right and
the value was wrong in all four.

Adding the reflection guard then surfaced nine further defects offline tests had
never checked:
  - Galaxy GoodLocalOverride  0x00D80000 -> 0x00960000  (not a UA code at all)
  - Galaxy UncertainLastUsableValue        0x40A40000 -> 0x40900000
  - Galaxy UncertainSensorNotAccurate      0x408D0000 -> 0x40930000
  - Galaxy UncertainEngineeringUnitsExceeded 0x408E0000 -> 0x40940000
  - Galaxy UncertainSubNormal              0x408F0000 -> 0x40950000
  - TwinCAT BadOutOfService   0x80BE0000 -> 0x808D0000 (was BadProtocolVersionUnsupported)
  - TwinCAT BadInvalidState   0x80350000 -> 0x80AF0000 (was BadAttributeIdInvalid)
  - AbCip/AbLegacy GoodMoreData 0x00A70000 -> 0x00A60000 (was GoodCommunicationEvent)
  - Historian.Gateway GatewayQualityMapper Good_LocalOverride 0x00D80000 -> 0x00960000

Galaxy's whole Uncertain block read as though the OPC DA quality byte could be
shifted into the UA substatus position; it cannot — the substatuses are an unrelated
enumeration. GatewayQualityMapper already held the correct table, which is what the
Galaxy values are now reconciled against.

Guard: StatusCodeParityTests (Core.Abstractions.Tests, which already project-
references every driver) reflects over every `const uint` in the deployed
ZB.MOM.WW.OtOpcUa.Driver.*.dll whose name reads as a status code, and asserts it
equals Opc.Ua.StatusCodes.<name>. Discovery is by convention, so a new driver
assembly referenced by that project is covered with no edit here. It went red on all
nine defects above before the fixes and now checks 109 constants green.

Because reflection can only see a NAMED constant, two inline literals were hoisted so
the guard can reach them: Galaxy's BadTimeout/Bad into StatusCodeMap, and
GatewayQualityMapper's 15-entry table into a new HistorianStatusCodes. An inline
`0x800B0000u, // BadTimeout` at a call site is exactly how the Galaxy defect survived.

The drivers stay SDK-free by design; only the test project references Opc.Ua.Core,
as the oracle.

Also corrected: tests that pinned the wrong values (Galaxy StatusCodeMapTests,
SampleMapperTests, GatewayQualityMapperTests — all written from the same bad source),
a mislabelled comment in DriverInstanceActorTests, and stale constants in two design
docs, one of them the unexecuted MTConnect driver design that would have propagated
BadNoData's wrong value into a new driver.

The CLI's SnapshotFormatter value->name table was checked against the SDK and is
correct; no change needed.
2026-07-25 15:34:31 -04:00
Joseph Doherty d5bd4226ee docs(mqtt): Sparkplug P2 live-verified; MQTT driver complete
Task 26 — the P2 milestone gate. Ran the live /run verification on an isolated
docker-dev rig (project otopcua-mqtt, ports 9210/4850-4851/14350, image built
from this branch) against the real Mosquitto TLS+auth broker and the C#
Sparkplug edge-node simulator on 10.100.0.35, and recorded the result.

The gate found three defects. Two are the same defect class the P1 gate found
twice — a hand-maintained AdminUI surface left behind by a driver-side feature —
and the third is a pre-existing cross-driver bug that only a Sparkplug flow
could surface.

  1. CRITICAL, FIXED — MqttDriverForm still shipped its P1 Sparkplug PLACEHOLDER.
     Switching Mode to SparkplugB rendered a "not available yet" notice and NO
     Group ID field, so with Sparkplug ingest fully shipped there was still no
     way to author a Sparkplug driver from the AdminUI at all. Sparkplug.GroupId
     is the driver's entire subscription filter (spBv1.0/{GroupId}/#): blank ⇒
     connected, Healthy, ingesting nothing. Now authors all five Sparkplug keys,
     MERGES over the existing sub-object rather than replacing it (so a key a
     newer driver adds inside it survives an older AdminUI), leaves it untouched
     in Plain mode, and validates the group id as the topic segment it is.
     Pinned by 8 MqttDriverFormModelTests cases, verified falsifiable — 8 RED
     with the fix stubbed out.

  2. PRE-EXISTING + CROSS-DRIVER, FIXED — every node label in the shared
     DriverBrowseTree was an <a href="#">. In a Blazor Web App, blazor.web.js's
     enhanced-navigation click interceptor resolves a bare "#" against
     <base href="/">, so clicking ANY browse-tree node label navigated the whole
     AdminUI to "/", tore down the circuit, and destroyed the hosting modal —
     losing the browse session AND the tag selection. @onclick:preventDefault
     does not help: it suppresses the browser's default action, not Blazor's own
     interceptor. Labels are now <button type="button">. Dates to the component's
     introduction (2026-05-28) and affects EVERY driver's picker; it surfaced
     only now because choosing a rebirth scope is the first flow that requires
     clicking a label rather than the ▶ toggle (always a button, always fine).

  3. FIXED (mitigation) — the browse tree rendered exactly once, at open, and
     never again, while OpenAsync returns as soon as the SUBSCRIBE is granted.
     On Sparkplug that means it is almost always empty forever, because births
     are never retained. Added a Refresh button that re-reads the root against
     the SAME session (nothing reconnects, nothing observed is lost, the tag
     selection is kept, only the armed rebirth scope is cleared).

Live gate result (all against the real broker + simulator, group OtOpcUaSim):

  - driver authored end-to-end through the fixed MqttDriverForm; blob is
    Mode:SparkplugB + Sparkplug.GroupId:OtOpcUaSim with enums as names
  - browse: BROWSER OPEN chip, Sparkplug-only rebirth panel, tree renders
    Group → EdgeNode → [Device] → Metric with the device folder Filler1 and
    node-level metric leaves SIDE BY SIDE, and "Node Control/Rebirth" as ONE
    leaf (the metric-name-is-not-a-topic-segment rule holding)
  - rebirth: group scope names the group + the 32-node cap, Cancel published
    NOTHING (simulator log unchanged); edge-node scope → "1 command published"
    and the simulator logged "rebirth NCMD #1 received; republishing metadata";
    group scope → "2 commands published", both edge nodes re-birthed; a device
    and a metric both resolve UP to "edge node EdgeA"; the panel does NOT render
    for a Plain MQTT device
  - browse-commit wrote bindable tuples with no topic/address key —
    {"groupId","edgeNodeId","metricName","deviceId"} for the device metric and
    deviceId ABSENT (not blank) for the node-level one, datatypes inherited from
    the birth (Int64 / Float)
  - deployed (Sealed), and both nodes served live changing values through OPC UA
    at the 2 s cadence — Good 0x00000000, no BadNodeIdUnknown
  - death→STALE: stopping the simulator drove both nodes to 0x80000000 with an
    empty value ~2 s later, and restarting it recovered them to Good on the new
    birth (FillCount back to its birth-declared 1000, then counting)
  - rediscovery fired exactly TWICE (once per authored scope: OtOpcUaSim/EdgeA
    7 metrics, OtOpcUaSim/EdgeA/Filler1 3 metrics) and was then gated across
    many subsequent births/rebirths — the anti-storm change gate working, and
    EdgeB correctly filtered out as an unauthored scope
  - tag editor: opens in SparkplugB (mode inference on reopen) with all four
    descriptor fields populated; blank group → "A Sparkplug group ID is
    required."; "Plant/1" rejected; "Node Control/Rebirth" ACCEPTED and saved
    with the slash whole; dataType override persists and its key is ABSENT again
    after selecting "(from birth certificate)"

Two things are NOT verified, and are recorded rather than claimed:

  - Rediscovery is INERT in v3 and this is a platform gap, not an MQTT one:
    nothing subscribes to IRediscoverable.OnRediscoveryNeeded and
    DriverHostActor.HandleDiscoveredNodes hard-returns. A DBIRTH introducing a
    metric does NOT change the OPC UA tree; redeploy. Verified from the driver's
    log line only, exactly as far as it can be verified.
  - A metric name containing "/" cannot be BROWSE-COMMITTED: the derived raw tag
    Name is a RawPath segment and may not contain "/", so the spec-mandatory
    "Node Control/Rebirth" is refused ("Row 3: Name must not contain '/'"). The
    refusal is loud and all-or-nothing, never a silently mis-bound tag, and
    Manual entry is the working path. Fixing it needs a name-sanitisation policy
    with a collision answer, so it was recorded rather than guessed at.

Also left open + documented: an empty browse tree cannot arm a rebirth (the
scope comes from a tree click, and the session side already accepts a bare
{group}/{edgeNode} — only a UI path is missing); _canRebirth is captured at
browse-open; the tag editor injects the Plain-only payloadFormat key into a
Sparkplug blob (cosmetic — the factory routes on the tuple).

Suites: offline 1528 passed / 0 failed (581 Driver.Mqtt + 809 AdminUI + 138
Core.Abstractions); live 15/15 against the broker + simulator.

Docs: docs/drivers/Mqtt.md brought fully up to date for P2 (Sparkplug config
sub-object, both tag shapes, the ingest state machine, rediscovery, browse +
rebirth + Refresh, a Known-gaps table); Mqtt-Test-Fixture.md gains the simulator
and drops its "Sparkplug has no fixture" claims; infra/README.md §3 gains the
simulator row; CLAUDE.md gains the simulator endpoint facts; the tracking doc
marks MQTT/Sparkplug COMPLETE. docker-dev/docker-compose.mqtt.yml is the
isolated-rig overlay the gate ran on.

Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-25 01:11:56 -04:00
Joseph Doherty 8d9155682d fix(mqtt): browse-commit writes a bindable address + a Request-rebirth affordance
Two gaps the Task 23/24 review found, both blocking Task 26's live gate.

Gap 1 — browse-commit produced a silently dead MQTT tag. RawBrowseCommitMapper
had no `Mqtt` case, so a committed leaf fell through to the generic
`{"address": …}` key. Neither MqttTagDefinitionFactory entry point reads
`address`: the tag deployed clean and reported BadNodeIdUnknown forever, with
no signal at commit time. Predates Task 23 (Plain was affected too), but Task 23
built the Sparkplug metric tree precisely so an operator could browse and commit
a binding.

The address is a DESCRIPTOR, not a reference string, and it cannot be recovered
from the browse node id: `{group}/{node}[/{device}]::{metric}` where a metric
name legitimately contains `/` (`Node Control/Rebirth`) — the ambiguity
MetricSeparator's remarks already name. So the session STATES it, via a new
`AttributeInfo.AddressFields` seam, and the mapper reads it. Which keys are
emitted is also how the mapper learns Plain vs Sparkplug — the driver type
reaching it is just `Mqtt`, and the mode lives on the driver config. Key names
are single-sourced in the new `MqttTagConfigKeys` (producer, mapper, factory),
with the literals pinned by a test so a symmetric rename cannot silently unbind
already-persisted blobs. A leaf with no stated address is refused at commit in
words rather than committed dead.

Gap 2 — RequestRebirthAsync had no UI. Task 23 shipped it backend-only; Task 26
step 1 assumes the button, and Task 25's runbook notes the picker tree stays
empty until a birth lands, so it is the only way to fill it on demand. Added to
the /raw browse modal: scope = the clicked tree node (device/metric resolve up to
their edge node, group fans out and is refused whole past 32), an explicit
two-click confirm naming the resolved scope and its consequence, the outcome or
the refusal shown rather than swallowed. Offered only for a Sparkplug session
(new `IRebirthCapableBrowseSession.RebirthAvailable` — one session class serves
both modes, so a type test alone would draw a button that can only throw) and
only to a DriverOperator; the server-side gate remains the boundary.

Tests: MQTT 545 → 581, AdminUI 781 → 800. The round-trip tests feed the emitted
blob to the REAL factory and were falsified by mutating the emitted key name.

Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 23:43:07 -04:00
Joseph Doherty 92ba120964 feat(mqtt): MqttDriverForm + MqttDeviceForm — the driver/device config forms P1 omitted
The P1 live gate had to insert MQTT driver config directly via SQL: DriverConfigModal and
DeviceModal both fell through to "No typed config form for driver type Mqtt" with no raw-JSON
fallback, so broker host/port/TLS/credentials were unauthorable from the AdminUI. Task 12 built
the *tag* editor; these are the driver + device surfaces.

MqttDriverForm authors the whole MqttDriverOptions connection surface (host/port/clientId,
TLS + CA pin, credentials, protocol version/clean-session/keep-alive, connect timeout, reconnect
backoffs, mode, maxPayloadBytes, and the Plain sub-object). The Sparkplug sub-object stays P2 —
a marked placeholder mirroring MqttTagConfigEditor's stub, with any existing sparkplug keys
preserved untouched.

The connection is authored on the DRIVER, not the device — unlike Modbus/S7/OpcUaClient and
contrary to what docs/drivers/Mqtt.md said. DriverDeviceConfigMerger merges a device's keys up
only when the driver has exactly ONE device, so a device-authored broker connection vanishes
silently the moment a second device is added. MqttDeviceForm is therefore informational (the
GalaxyDeviceForm shape) and round-trips DeviceConfig verbatim; it flags legacy connection keys
left on a device by a pre-form deployment, because those still win via merge-up.

Serialization goes through the ONE shared MqttJson.Options instance (Task 9's decision), never a
fifth per-form copy — pinned by an assertion that an ordinal-only reader CANNOT bind the emitted
blob, and by extending the fleet-wide DriverPageJsonConverterTests guard to resolve a form's
serializer from an explicit external-instance registry when it has no _jsonOpts field. Dropping
the converter from MqttJson.Options reddens 3 tests and leaves the symmetric round-trip green —
the Task 9 lesson, reproduced.

RawTags is stripped from the emitted blob (the deploy artifact owns it) and unknown top-level
keys survive a load->save. Validation mirrors the driver's own [Range] bounds inline, and
ToOptions() additionally clamps, so an ignored error still cannot persist a
connectTimeoutSeconds:0 driver-brick. A non-blank clientId raises the P1 live-gate warning
inline (fixed ids make redundant pair nodes evict each other while both report Healthy).

AdminUI 761/761 green (was 730), TWAE-clean; Driver.Mqtt 266/266 green.

Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 20:41:48 -04:00
Joseph Doherty 07a4a5ff5e docs(mqtt): P1 plain-MQTT milestone live-verified; endpoint recorded
Task 14 — the P1 milestone gate. Ran the live /run verification on a docker-dev
rig against the real Mosquitto TLS+auth fixture, and recorded the result.

The gate did its job: it found MQTT was unauthorable in production.

  RawDriverTypeDialog's driver-type list is a hand-maintained array that nobody
  added MQTT to, so the /raw "New driver" picker never offered it — with every
  other layer (contracts, driver, browser, factory, host registration, typed tag
  editor) complete and 266 green unit tests. Nothing tied that array to
  DriverTypeNames and AdminUI has no bUnit, so no offline test could see it.
  Fixed, plus RawDriverTypeDialogParityTests: a reflection parity guard that
  fails for ANY DriverTypeNames entry missing from the picker. Verified
  falsifiable — RED with "…cannot be authored from the /raw New-driver picker,
  so they are unreachable in production: Mqtt" before the one-line fix.

A second gap is left OPEN and documented, not fixed (no task ever covered it):
MqttDriverForm / MqttDeviceForm do not exist, and DriverConfigModal/DeviceModal
have no raw-JSON fallback — so an operator can create an MQTT driver but cannot
author its broker endpoint or credentials. P1 is not operator-complete until
those two razor forms land. The gate authored config via SQL to get past it.

Live gate result (isolated 2-node MAIN stack, image built from this branch,
fixture at 10.100.0.35:8883, AllowUntrustedServerCertificate rather than
pinning the CA into the rig):

  - typed MQTT tag editor renders and round-trips; Json shows the JSON-path
    field, Raw/Scalar hide it; wildcard topic a/+/c blocked at save; data-type
    list offers Float64 and no Double; qos/retainSeed absent on "(driver
    default)" and qos:2 written as a number; isHistorized/historianTagname
    survive a topic-only edit; SparkplugB renders the P2 placeholder and
    switching back keeps Plain values; jsonPath is guidance not a gate in all
    three shapes ($ seeded only for a brand-new blank tag, blank stays absent,
    clearing saves fine)
  - deployed, and both editor-written blobs resolved and served changing live
    values through OPC UA (22.8 / 1629, StatusCode Good) — no BadNodeIdUnknown
  - the bespoke #-observation browser drove a real broker session and rendered
    the fixture's actual topic tree (line1/{counter,state,temperature},
    noise/chatter, retained/seed); a Modbus device's picker still correctly
    reports "Browsing unavailable"

Also found live and documented (not a code change): both nodes of a redundant
pair run the driver, so a FIXED clientId makes them evict each other forever —
the broker logs "already connected, closing old connection" and both nodes
reconnect every ~2s while still reporting Healthy. Unset (the default) is
correct; confirmed 0 reconnects/60s on both nodes after removing it.

Suites: offline 1134 passed / 0 failed (266 Driver.Mqtt + 730 AdminUI incl. the
3 new guards + 138 Core.Abstractions); live 7/7 against the fixture.

Docs: new docs/drivers/Mqtt.md + Mqtt-Test-Fixture.md (the per-driver + fixture
convention every other driver follows), MQTT rows in docs/drivers/README.md,
TestConnectProbes.md, root README.md, and infra/README.md §3.

CLAUDE.md drift corrected while adding the MQTT endpoints:
  - the "every fixture carries project: lmxopcua" claim was false — only the
    MQTT fixture does; the filter returns one stack, not the fleet
  - lmxopcua-fix.ps1 is Windows-VM-only; on macOS drive the host over ssh/rsync
    (and the docker-dev rig itself runs locally under OrbStack)

Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 18:44:43 -04:00
Joseph Doherty e27eb77187 docs(modbus-rtu): record Wave-1 RTU-over-TCP live /run gate result (PASSED)
v2-ci / build (pull_request) Successful in 3m45s
v2-ci / unit-tests (pull_request) Failing after 13m54s
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 15:50:10 -04:00
Joseph Doherty 7a9caf141c docs(drivers): add worktree + subagent execution commands to the tracking doc
v2-ci / build (push) Successful in 3m46s
v2-ci / unit-tests (push) Failing after 14m11s
Per-plan copy-paste command (subagent-driven-development in a git worktree),
plus the slash-command and executing-plans/resume alternatives, and a note that
the four independent plans can run in concurrent worktrees.

Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 13:24:36 -04:00
Joseph Doherty 76e55fc112 docs(drivers): Wave 0-2 tracking doc + Wave 1/2 implementation plans
Add a living progress tracker (docs/plans/2026-07-24-driver-expansion-tracking.md)
for the driver-expansion program's Waves 0-2, linked from the program design doc's
document map. One row per deliverable pointing at design + implementation plan + status.

Add executable implementation plans (plan .md + co-located .tasks.json) for the four
Wave 1/2 drivers, each authored by writing-plans methodology off its design doc and
mirroring the relevant existing driver:

- Modbus RTU        11 tasks  (extends Driver.Modbus; RTU-over-TCP, direct-serial descoped)
- SQL poll          22 tasks  (ISqlDialect seam, SQL Server only in v1; SQLite + central-SQL fixtures)
- MTConnect Agent   23 tasks  (browse free via Wave-0 seam; TrakHound-vs-hand-rolled = Task 0)
- MQTT/Sparkplug B  27 tasks  (P1 plain MQTT 0-14 then P2 Sparkplug 15-26; MQTTnet-5 pinning spike = Task 0)

Wave 0 (universal browser) remains merged (056887d6) with its live gate open (#468).
All four new plans are design-only -> plan-ready; nothing built yet.

Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 13:17:44 -04:00
Joseph Doherty d1dac87f6f docs: record the bootstrap guard (CLAUDE.md + Phase 7 note)
v2-ci / build (push) Successful in 4m38s
v2-ci / unit-tests (push) Failing after 16m7s
The simultaneous-cold-start split-brain, carried as a Phase 7 "candidate follow-up,
not shipped", is now closed by the opt-in Cluster:BootstrapGuard (279d1d0f). Documents
the guard in CLAUDE.md's bootstrap section and marks the Phase 7 finding closed.

Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 08:35:16 -04:00