Joseph Doherty 01a2013ea3 fix(adminui): CSV import grid shows the raw name/group of an invalid row (#847) 2026-11-11 03:41:54 -05:00
Joseph Doherty 61b9adeb9c Merge branch 'master' into fix/832-docker-dev-batch 2026-11-11 02:32:42 -05:00
Joseph Doherty e9064dbdf4 Merge fix/815-credential-ref-scoping
# Conflicts:
#	.claude/rules/drivers.md
#	docs/drivers/Heidenhain.md
2026-11-11 02:08:24 -05:00
Joseph Doherty 4563940792 fix(security): warn-only compatibility for deployed drivers + upgrade preflight (#815)
User decision: save, Test Connect, live browse and the deploy gate keep
refusing out-of-namespace credential references, but an ALREADY-DEPLOYED
driver must not fault at the upgrade restart or (Galaxy) at the next
gateway reconnect, since ReopenAsync re-resolves Gateway.ApiKeySecretRef.

- LegacyCredentialReferenceTracker (Core.Abstractions): the one, deprecated,
  call-site-chosen compatibility path. Running Galaxy (InitializeAsync,
  ReopenAsync, ack fallback) and OpcUaClient (session open) pass it and keep
  the pre-#815 semantics (case-insensitive prefixes, Galaxy file:, OpcUaClient
  literal pass-through) with a rate-limited Warning (driver/field/allowed
  form, never the value) and a credential-compat:<field> diagnostics entry
  (both drivers now implement IDriverDiagnostics). Browsers and probes pass
  none and stay hard-fail; Heidenhain has none.
- Deploy-gate message names the migration.
- Upgrade preflight: CredentialReferencePreflightService (admin nodes, once
  after ApplicationStarted, ConfigDb only, resolves nothing) logs a Warning
  per Draft row / Deployed-artifact finding; the /raw banner shows them plus
  Running drivers reporting warn-only use (driver-health diagnostics).
- docs/security.md: exact replacement table (incl. the old form default
  env:MX_API_KEY, file:, un-namespaced secret:, casing changes), the
  ReopenAsync reconnect behaviour, the warn-only window and its removal.

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-11 02:07:33 -05:00
Joseph Doherty d3285af6b3 Merge feat/830-heidenhain-followups 2026-11-11 01:55:10 -05:00
Joseph Doherty 9aff90f884 fix(opcuaclient): never pass checkDomain for a None endpoint; document both SDK check sites (#816 review)
SDK 2.0.1 checks the server host name in TWO places: Session.OpenAsync (after
the chain is trusted) and DefaultSessionFactory.CreateChannelAsync, against the
certificate in the GetEndpoints reply and before any security-mode test. opc-plc
sends a certificate on its None endpoint, so `connect -u
opc.tcp://10.100.0.35:50000 --validate-host-name` was refused on an
unauthenticated channel, where a host check proves nothing.

All three call sites now pass checkDomain only when the selected endpoint's
SecurityMode != None: OpcUaEndpointSelection.CheckDomainFor for the driver
(OpenSessionOnEndpointAsync, so the failover sweep too) and the AdminUI browser;
the same expression in Client.Shared ConnectToEndpointAsync (shared by
failover). New live tests: driver None + flag on vs :50000 reads; browser None +
flag on vs the NAT fixture browses; the secure + flag refusals still hold.

Docs: name both check sites; a zone-qualified IPv6 host never matches (FindDomain
compares the zone too), so link-local needs validateServerHostName=false; the
match is loose (first label alone, subject DC= parts count, no wildcards), which
caveats the CA recommendation.
2026-11-11 01:53:01 -05:00
Joseph Doherty 8a6f0e3c84 fix(mtconnect): the Agent refuses count ABOVE bufferSize, not at it (#825)
Live gate against the cppagent 2.7 fixture: count=16384 with bufferSize
16384 streams; 16385 is OUT_OF_RANGE ('count' must be less than 16385).
Warn only when SampleCount > bufferSize, pin both sides of the edge
against the live Agent, and correct the #804 wording that said 'at or
above'.
2026-11-11 01:38:48 -05:00
Joseph Doherty e6cba4bc18 fix(adminui): Heidenhain authoring UX — CSV preview runs the save-path row rule, dictated data type is locked, credential error shown once (#830)
- RawTagRowRules: the ONE driver-dispatched authority on Tag-ROW rules (access level /
  Tag.DataType). RawTreeService's save path, the CSV import's staged review grid
  (RawTagCsvMapper) and the manual-entry grid all call it; no call site names a driver.
  A ReadWrite or mistyped Heidenhain row is now invalid IN THE PREVIEW instead of only at Commit.
- Manual-entry grid + tag modal: when the driver dictates the data type for the row's
  address (RawTagRowDefaults.DictatedDataType), the field is a locked read-only value instead
  of a select that commit silently replaced; the grid runs the row rule client-side and no
  longer rewrites the row at commit.
- Driver/device modals: the credential refusal is shown once (the modal's save-gate notice);
  HeidenhainDriverFormModel / HeidenhainDeviceModel.Validate report only ranges / endpoint.
- docs/drivers/Heidenhain.md: #831 alarm conditions + rediscovery, #830 authoring behaviour.

Tests: HeidenhainAuthoringUxTests (CSV preview == ImportTagsAsync row-for-row, dictated type
is what the save path accepts, single credential surface, ALARM: seeding, CSV alarm rows,
AlarmMs round-trip); HeidenhainAuthoringTests updated for the single-notice rule.
2026-11-11 01:37:51 -05:00
Joseph Doherty 2b0eed1a8f feat(heidenhain): controller alarms as native Part 9 conditions; rediscovery on identity change (#831)
- ALARM: selectors (HeidenhainAlarmSelector, Contracts): ALARM:*, ALARM:OTHER,
  ALARM:CLASS=<r>[/GROUP=<r>][/NUMBER=<r>] (<r> = n | lo..hi; negative numbers allowed).
  An ALARM: address and the cross-driver alarm object only work together — the factory
  refuses either alone, so editor, save path, CSV and deploy inspector agree. Data type
  fixed Boolean; never a value (ReadAsync BadNotSupported), never in a data subscription.
- HeidenhainDriver implements IAlarmSource: one condition per ALARM: tag at its RawPath,
  driven by the SAME allowlisted R_RI 27/28 walk on the control's single loop, on the new
  Polling.AlarmMs cadence (default 2000 ms, only for controls carrying an ALARM: tag).
  FOCAS #647 transition rules (Raise / Retrigger / Clear), identity = class+group+number+text,
  deterministic display order, told-record on the driver instance, recorded only while a
  handler listens. A failed walk (refusal, overflow, comms loss) is quality-only, never a clear.
- Acknowledge is LOCAL-ONLY: AcknowledgeAsync is a no-op success (FOCAS/MTConnect posture);
  Lsv2ReadOnlyPolicy is unchanged — no ack or write request exists.
- Opt-in per tag, no driver flag (FOCAS #647 / MTConnect #626 precedent); Alarms/* arrays unchanged.
- IRediscoverable: a reconnect whose R_VR identity (model / NC / PLC / options) differs from
  the previous session raises OnRediscoveryNeeded once (advisory re-browse chip). No extra traffic.
- AdminUI: Heidenhain joins NativeAlarmModel's alarm drivers; the typed editor fixes ALARM:
  tags at Boolean and seeds/drops the alarm object with the selector; driver form gains
  "Alarm conditions (ms)". (HeidenhainDriverFormModel also carries the #830 credential-notice change.)

Tests: HeidenhainAlarmTests (grammar, pairing, rules, simulator e2e with the captured iTNC 530
alarm record, local-only ack = zero bytes sent, quality-only outage/refusal, rediscovery),
Runtime.Tests HeidenhainNativeAlarmEndToEndTests (real DriverHostActor condition), a
DraftValidator case, and the NativeAlarmDriverSetGuard now scans the Heidenhain driver.
2026-11-11 01:37:41 -05:00
Joseph Doherty ae91e6b7f7 feat(opcuaclient): opt-in server-certificate host-name check; NAT fixture keeps its PKI (#816, #818)
#816 finding: the SDK checks that the server certificate names the host only
when a session is created with checkDomain:true. The driver, the AdminUI
browser and Client.Shared all called the 8-argument
DefaultSessionFactory.CreateAsync, which forwards checkDomain:false — so no
host-name check ever ran (why a trusted NAT cert for *.invalid browsed fine
over an IP in #813). When enabled the SDK (Session.OpenAsync ->
ValidateDomains -> FindDomain) compares ConfiguredEndpoint.EndpointUrl.IdnHost
— the CONFIGURED host, because OpcUaEndpointSelection/EndpointSelector
rewrote the advertised one — against the cert's DNS/IP SANs; secured
sessions only, and the auto-accept handler accepts a mismatch.

Policy: certificateValidation.validateServerHostName, tri-state. Unset =
OpcUaCertificateValidationOptions.DefaultValidateServerHostName = false, the
pre-#816 behaviour, so nothing changes on upgrade; true = validate the
configured host; false = explicit NAT/port-publish opt-out. Threaded into the
driver, the AdminUI browser (same JSON) and the AdminUI form (a select that
keeps "unset" unset), Client.Shared ConnectionSettings.ValidateServerHostName
and the CLI --validate-host-name. A driver refusal names the opt-out.

#818: the NAT fixture's /app/pki is on the opc-plc-nat-pki volume (verified:
same thumbprint across --force-recreate), its PUBLIC cert is committed as
Docker/nat/opc-plc-nat-server.der, and NatPublishedEndpointBrowseTests run
every secure browse on a throwaway PKI (internal browser seam): refusal with
nothing trusted, positive with the cert trusted (unset/false host check), and
a BadCertificateHostNameInvalid refusal with the check on. The trusted cert is
OPCUA_NAT_SERVER_CERT or the committed one (skip on thumbprint mismatch);
OPCUA_NAT_SERVER_CERT_TRUSTED is retired. CI exports its throwaway NAT
container's public cert. ServerHostNameValidationTests pin the driver against
the plain opc-plc. MIN_EXECUTED not raised (needs a hosted run): +6 in
v2-integration (440 -> 446), documented in scripts/ci/README.md.
2026-11-11 01:33:00 -05:00
Joseph Doherty a224fd6391 fix(security): scope operator-authored credential references per driver (#815)
A Designer could point a Galaxy / OpcUaClient endpoint at a host they control,
set a credential field to any reference the node can resolve
(env:ConnectionStrings__ConfigDb, env:ServerHistorian__ApiKey, secret:<any>,
Galaxy file:<any path>) and click Test Connect / live browse; the node resolved
the value and sent it to that host.

One shared rule in Core.Abstractions (CredentialReferences +
DriverCredentialPolicy) generalises the #803 Heidenhain namespace:
- Galaxy: secret:galaxy/... | secret:otopcua/galaxy/... | env:OTOPCUA_GALAXY_... |
  legacy env:GALAXY_MXGW_...; file: refused; dev:/literal API key unchanged.
- OpcUaClient: secret:opcuaclient/... | env:OTOPCUA_OPCUACLIENT_...; literals unchanged.
- Heidenhain adopts the shared parser/resolver (namespace unchanged).
Enforced at the AdminUI save path (DriverConfigSaveGate), the deploy gate
(CredentialReferenceDeployChecks, code CredentialReferenceOutOfScope), Test
Connect (AdminOperationsActor, before any probe), live browse
(BrowserSessionService, before any browser) and again at resolve time in every
driver/browser (fail closed, before any store/env read).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-11 01:28:58 -05:00
Joseph Doherty f8f6781a24 feat(mtconnect): warn at Test Connect and deploy when SampleCount >= the Agent bufferSize (#825)
Parse the /probe Header bufferSize; MTConnectDriverProbe reads sampleCount
(default 1000) and answers Ok with a WARNING message (amber chip in the
Test Connect button); InitializeAsync logs the same Warning and exposes
agentBufferSize on the diagnostics bag. Live-checked against the shared
cppagent fixture (bufferSize 16384).
2026-11-11 01:23:33 -05:00
Joseph Doherty 5bbe1e3c7a fix(heidenhain): resolve the probe's secret resolver lazily — eager resolution crash-looped central nodes at boot (#803)
v2-ci / unit-tests (push) Successful in 1h9m7s
The Test-Connect probe set is resolved inside the AdminOperations Akka starter; resolving
ISecretResolver there walks AddZbSecrets -> IAuditWriter -> ActorAuditWriter, whose ctor needs
AuditWriterActorKey (registered later in the same builder). Found by the docker-dev live gate.
Regression test: resolving the probe set never resolves ISecretResolver (fails before the fix).
Also: TagRowProblem doc comment re-attached; Heidenhain credential help text names the
secret:heidenhain/ and env:OTOPCUA_HEIDENHAIN_ namespaces.
2026-11-11 00:27:37 -05:00
Joseph Doherty 54f58c583c fix(heidenhain): refuse literal credentials and writable/mistyped tags at the save path (#803 review)
- Review 1: RawTreeService Create/UpdateDriver and Create/UpdateDevice refuse a Heidenhain
  config whose password fields are not blank / secret:heidenhain/... / env:OTOPCUA_HEIDENHAIN_...
  (DriverConfigSaveGate over HeidenhainOptionsParser.DescribeCredentialProblems: top level,
  Access, Devices[], case-insensitive keys; the value is never echoed), so a literal password
  never reaches the draft DB. The driver and device modals show the reason and disable Save.
- Review 8: CreateTag/UpdateTag/ImportTags (tag modal, manual entry, CSV import, browse commit)
  refuse a ReadWrite Heidenhain tag or a Tag.DataType that disagrees with what the driver
  publishes (HeidenhainTagRules: catalog type, Float64 => Double, or the binding's dataType).
  The tag modal and manual-entry grid fix the access level at Read and derive the data type from
  the address (RawTagRowDefaults). New deploy gate HeidenhainTagDataTypeMismatch.
- docs/drivers/Heidenhain.md: credential namespace convention + why, the save-path and deploy
  enforcement, optional-role credential behaviour, BadConfigurationError, backoff/ordering notes.

Tests: HeidenhainSavePathTests (service save path; red with the gates disabled) and new
DraftValidatorHeidenhainTests cases.
2026-11-10 23:54:32 -05:00
Joseph Doherty 3641d56154 feat(heidenhain): AdminUI driver/device forms, typed tag editor, CSV + browse-commit (#803)
- HeidenhainDriverForm over HeidenhainDriverFormModel (JsonObject bag preserves Devices and
  unknown keys; no enum fields; Validate asks HeidenhainOptionsParser) + DriverConfigFormMap.
- HeidenhainDeviceForm/Model (Host, Port 19000, optional per-device password references)
  + DeviceFormMap. Literal passwords are refused in both forms.
- RawDriverTypeDialog entry; HeidenhainTagConfigEditor over HeidenhainTagConfigModel, whose
  Validate is the driver's own TryFromTagConfig; catalog leaves derive dataType + isArray;
  registered in TagConfigEditorMap + TagConfigValidator.
- CsvColumnMap (HhAddress/HhDataType/HhIsArray) and RawBrowseCommitMapper branch.
- Guards: DriverPageJsonConverterTests external-serializer entry, TagConfigNonEnumParityTests
  runtime map + corpus + freshly-authored rows, TagConfigRoundTrip, HeidenhainAuthoringTests.
2026-11-10 23:17:26 -05:00
Joseph Doherty 2331f7ed14 feat(sql): opt-in writes — allowWrites + per-tag writable, single-row parameterised UPDATE (lmxopcua#753)
v2-ci / unit-tests (push) Waiting to run
allowWrites is no longer inert: SqlDriver implements IWritable, default off.

- Gates (outermost first): node Writable + WriteOperate (server), driver
  allowWrites, the tag's own TagConfig "writable": true (strict JSON boolean;
  anything else refuses the tag, and the deploy gate says why), and a model that
  names exactly one row — KeyValue, or WideRow by where-pair. topByTimestamp and
  Query are BadNotWritable.
- SqlWritePlanner: the only statement a write can become is
  UPDATE <table> SET <value col> = @v WHERE <key col> = @k, built from the
  catalog-gate-canonical identifiers (dialect-quoted) with value and key bound;
  value-before-key marker order so positional ODBC binds correctly. No authored
  write SQL, INSERT, UPSERT or procedure.
- Executed in a transaction that commits only when exactly one row was touched:
  0 rows -> BadNoData (never inserts), >1 -> rolled back, BadConfigurationError,
  unknown count -> rolled back, BadNotSupported. Bounded by operationTimeout;
  provider errors -> BadCommunicationError; health untouched.
- Discovery advertises Operate only where a write could succeed.
- AdminUI: driver form's Allow writes switch is live; tag editor gains a
  per-tag write switch; model validates writable strictly (parity corpus).
- Factory no longer warns "allowWrites ignored"; it logs whether writes are on.
- Tests: SqlWriteTests (planner SQL/bind order/injection/coercion, every gate,
  readback, absent key, two-row rollback, gate-rejected tag, discovery);
  MySqlReadTests write legs against InnoDB (keyed row only, two-row rollback,
  server-side grant refusal, default-off). Seed adds a setpoints table and the
  one UPDATE grant.

(lmxopcua#753)

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 17:30:31 -05:00
Joseph Doherty 3c9ab4b668 feat(sql): Odbc provider — ANSI SQL:2008 profile over System.Data.Odbc (lmxopcua#753)
SqlProvider.Odbc is now constructed; every enum member is a working backend.

- OdbcDialect: System.Data.Odbc 10.0.14 (no vulnerable packages), ANSI double-
  quote quoting, positional `?` markers, INFORMATION_SCHEMA catalog (system
  schemas of the common backends excluded by name — the live gate caught
  psqlODBC listing pg_catalog), FETCH FIRST n ROWS ONLY limits, a conservative
  1000-parameter chunk. Positional binding is safe because every caller adds
  parameters in marker order (planner IN list, catalog schema-then-table).
- Named queries on a positional provider are checked by `?` count against the
  declared params (literals/comments ignored), since there is no name to match.
- Supported backends are those whose SQL accepts that profile (PostgreSQL via
  psqlODBC proven, Snowflake-like); SQL Server/MySQL/DB2 should use their native
  provider. The host needs the ODBC driver manager + vendor driver.
- Reserved-provider controls in factory/probe/browser tests now use an
  undeclared ordinal (99); the AdminUI form offers Odbc and a test pins the
  dropdown theory to SqlDialects.Supported.
- Tests: OdbcDialectTests (unit, any host). OdbcReadTests + Docker/odbc/
  run-odbc-gate.sh run the built suite in a throwaway Linux SDK container with
  unixODBC + psqlODBC against a throwaway seeded PostgreSQL: KV IN-list
  positional binding, where-pair, topByTimestamp via FETCH FIRST, a two-
  parameter named query, and the browse walk. macOS has no vendor ODBC driver,
  so there the suite skips.

(lmxopcua#753)

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 17:30:31 -05:00
Joseph Doherty 63372e757a feat(sql): MySql provider over MySqlConnector, one shared provider map (lmxopcua#753)
SqlProvider.MySql is now a constructed backend instead of a reserved name.

- MySqlDialect (Driver.Sql.Dialect): MySqlConnector 2.6.2 (MIT, fully managed,
  no vulnerable packages), backtick quoting with MySQL's 64-char / no-trailing-
  space rules, information_schema catalog SQL with the database as the schema
  (system databases excluded, aliases pinned), trailing LIMIT, a type map that
  also reads the reader-side spellings (INT UNSIGNED -> UInt32, BOOL -> Boolean).
- SqlDialects: the one provider -> dialect map. The factory, the Test Connect
  probe and the browse picker each carried their own switch (and drifted once);
  they now all read this, and their refusals list the supported/reserved sets
  from it.
- AdminUI driver form offers MySql.
- Tests: MySqlDialectTests (golden quoting/catalog/type map/planner SQL); the
  provider-gate tests in factory, probe, browser and form now treat MySql as
  supported and Odbc as the reserved control. MySqlReadTests + Docker/mysql
  (throwaway mysql:8.4, SELECT-only login): liveness, KV/wide-row/topByTimestamp,
  INT keys vs authored text, case folding against case-sensitive table names,
  catalog rejection, browse walk, factory+probe, named query with a bound
  parameter, and a writing stored function whose effect the rolled-back
  transaction discards.

(lmxopcua#753)

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 17:30:31 -05:00
Joseph Doherty a68593e714 feat(sql): named-query tag model — read-only SELECTs declared on the driver (lmxopcua#753)
SqlTagModel.Query (design §5.4) is now served end to end instead of refused.
The driver config declares `queries` (name -> sql, params, maxRows); a tag names
the query, the result `column` it reads and optionally a `rowKey` picking its row.

- Parser/deploy gate: query + column required, rowKey all-or-nothing; Inspect
  explains each refusal. Table is not read for this model.
- SqlReadOnlyStatement: single SELECT/WITH only, no data/schema-changing keyword
  outside literals/comments (refuses SELECT INTO, FOR UPDATE, DML CTEs). Shared by
  the factory and the AdminUI driver form (SqlNamedQueryRules.Describe), so the
  form refuses what the driver refuses. One bad entry fails the driver.
- Parameters are always bound; the factory refuses a declared parameter whose
  dialect marker the statement never uses.
- Reader: one execution per query per poll, inside a transaction that is always
  rolled back; result columns matched exact-then-unique-CI; no row -> BadNoData,
  ambiguous row / missing column / over maxRows -> BadConfigurationError.
- Catalog gate passes Query tags through (nothing is quoted into SQL); a
  Query-only driver skips the catalog load. A tag naming an undeclared query is
  skipped with the reason on /hosts.
- AdminUI: typed editor offers Query (query/column/rowKey); driver form edits
  `queries` as JSON and keeps the last valid set on a typo.

(lmxopcua#753)

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 17:30:31 -05:00
Joseph Doherty dc0a24f224 feat(galaxy): operator-authenticated alarm ack — send Galaxy credential to mxaccessgw (#749)
v2-ci / unit-tests (push) Failing after 1h8m43s
mxaccessgw 488649c+ acknowledges by AuthenticateUser as the operator and
writing <alarm>.AckMsg, so AcknowledgeAlarmRequest now needs a real Galaxy
operator_user + operator_domain + operator_password. The OPC UA data plane is
API-key/anonymous and carries no Galaxy password, so the driver resolves the
account per ack:

1. the session's API key's Galaxy ack identity, set on AdminUI /apikeys and
   held ONLY in the encrypted Secrets store
   (otopcua/apikeys/<keyId>/galaxy-ack-{user,password}); a key with a user but
   no password secret is refused, never silently downgraded;
2. else the driver instance's AlarmAck fallback account (DriverConfig
   FallbackUser/FallbackDomain/FallbackPasswordSecretRef; secret:/${secret:}/
   env:/file:/dev: only — a literal is refused);
3. else DriverOperationRefusedException: nothing is sent, never an empty
   operator_user. Refusals are excluded from the resilience retry/breaker.

- Pins ZB.MOM.WW.MxGateway.Client/Contracts 0.2.1 -> 0.3.0 (vendored into
  nuget-packages/ from the Gitea feed, per the local-mxgw source mapping).
- The session ApiKeyId (not a secret) rides NativeAlarmAck ->
  RouteNativeAlarmAck -> RouteAlarmAck -> AlarmAcknowledgeRequest; the password
  is resolved in the driver and never travels through actor messages.
- The OPC UA principal + key id are appended to the AckMsg comment
  ("[OPC UA: <principal>, key <id>]") and logged, so a shared fallback
  account does not lose who acknowledged.
- Password never logged: GalaxyAckCredential.ToString omits it, the
  acknowledger scrubs it from every gateway message it echoes and withholds
  any exception that echoes it; audit rows carry only the key id.
- AdminUI: /apikeys "Ack identity" editor (set/remove; delete-key clears it),
  Galaxy driver form gains the fallback section.
- Synchronous OPC UA status for a refusal is follow-up #760 (the native ack
  path is fire-and-forget after the Part 9 method returns).

Tests: request mapping (password populated), password absent from logs and
exception text (mutation-checked), key-mapped / fallback / refused paths at
resolver and driver level, breaker non-trip, key-id propagation through node
manager and DriverHostActor, AdminUI service + form round-trip.

Closes #749
2026-11-06 16:23:00 -05:00
Joseph Doherty 0f1f8ad8fa fix(adminui): lane D-b review r0 fixes (I1, M1, M2, M5-M9, N1-N3, N5, H3)
I1: /hosts eviction keyed off the AUTHORED DriverInstances, so a driver
deleted in /raw but not yet deployed - still running, still publishing -
vanished every tick. The stores' sweep is now EvictUnconfiguredStale(set,
olderThanUtc): an entry goes only when unconfigured AND its PublishedUtc is
older than 60 s. Tests cover unconfigured+fresh kept (positive control),
unconfigured+stale evicted, configured+stale kept, and the deploy hand-off.

M1: Test Connect falls back to the driver's documented ProbeTimeoutSeconds
default (Galaxy 30, OpcUaClient 15, ...) when the key is absent.
M2: the budget never undercuts the config's root timeoutMs (+1 s).
M5: RawBrowseModal compares the open generation captured before the await,
so a close-then-reopen mid-open closes the stale session.
M6: /alarms-historian keeps a 30 s re-poll on 'not registered' (a driver
node may still be starting) instead of stopping for good.
M7: /scripts source fetch failure shows in the dialog, not the error boundary.
M8: the export modal maps only its preview rows; the endpoint writes via
Results.Text (no second byte[] copy).
M9: /hosts config queries are ordered, so SequenceEqual change detection holds.
N1 tooltip, N2 CRLF-safe regex, N3 throttled Warning for subscriber faults,
N5 equipment-import help text now describes RFC 4180 quoting.
H3: MonacoEditor documents that themes are page-global.

Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 18:21:46 -04:00
Joseph Doherty 01f7e3d62e Merge master 4fb04a9f (lane D-a) into remed/lane-D-b
ScriptEdit.razor conflict resolved keeping both D-a's on-demand Monaco sync +
Problems list and D-b's delete confirm.

Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 18:14:58 -04:00
Joseph Doherty 21cb50c51a feat(adminui): refresh the browse tree after a rebirth request (G2-F3)
RequestRebirthAsync now returns only once the requested births have arrived
and gone quiet, but the modal still told the operator to re-expand the tree in
a few seconds. ConfirmRebirthAsync re-keys the tree against the same session
(as the Refresh button does) when the session and modal are still current,
drops the now-stale armed scope, and keeps the outcome line.

Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 18:02:57 -04:00
Joseph Doherty 15bd409cdd fix(adminui): say why a Sparkplug array/unsupported metric cannot be committed (G2-F2)
Since R06:M-5 the Sparkplug browser states no address for a metric the
ingestor will not read and labels its descriptor 'not bindable', but the commit
refusal still said the attribute lookup returned nothing. RawBrowseModal keeps
the attribute's descriptor on the selection, and DescribeUncommittableLeaf
reports a 'cannot be bound in this version' message echoing it. A lookup that
really returned nothing keeps the old text. A test pins the marker to the
browser's own string.

Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 18:01:44 -04:00
Joseph Doherty 746267c2a2 fix(adminui): equipment CSV import reads RFC 4180 via CsvParser (R04 S6)
ImportEquipmentModal split each line on commas, so a quoted Manufacturer with
a comma silently shifted every later column. EquipmentCsvParser reads through
the shared Commons CsvParser (the raw-tag importer's authority): quoted
fields, doubled quotes, CRLF and blank lines parse; malformed quoting is an
error, not a guess. Header/shape messages are unchanged.

Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 17:56:26 -04:00
Joseph Doherty a9e8f5abfe fix(adminui): bound the diagnostics marker payload on both the endpoint and the circuit (D-a review r1)
I-1 - a non-C# paste produced thousands of Roslyn markers. The Problems-list report sent
them all as one JS->.NET message, which could exceed the 1 MB hub limit and kill the
circuit. The JS now sends at most MaxReportedMarkers (200) markers, errors first, each
message cut to 300 chars, plus the total. ScriptProblemReport.FromEditor clamps again
on arrival, and the Problems list shows "showing N of Total" / "+N more". The diagnostics
endpoint also bounds its response: Distinct, errors first, MaxDiagnosticMarkers (1000),
messages cut to 1000 chars. An error is always kept, so editor-accepts == publish-accepts.

M-1 - drop the per-instance compilation lineage; analyses derive from BaseCompilation.
M-2 - the VirtualTag modal clears its problems (and editor ref) on close and on a script
reload.
M-5 - an over-limit text is announced at blur (OnSyncRefused), not only at Save.

Refs #745

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 17:51:35 -04:00
Joseph Doherty e16146fa0c fix(adminui): close a browse session that opens after its picker is gone (R04 L4)
Every picker and RawBrowseModal stored the OpenAsync token after the await; if
the host was disposed (or the modal closed) meanwhile, its teardown had already
run with no token, so the plant-side session lived until the reaper's idle TTL.
BrowseOpenGuard.CloseIfOrphaned closes it at once; each host sets _disposed
first thing in DisposeAsync (RawBrowseModal also treats !Visible as gone).

Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 17:51:34 -04:00
Joseph Doherty 4b594ec525 fix(adminui): Test Connect honours the configured probe timeout; drain its clear timer (R04 L2, G1-F5, F-FU2)
DriverTestConnectButton always sent a fixed 10 s, and the Galaxy/OpcUaClient
probes run under min(caller, configured), so ProbeTimeoutSeconds - documented
on every driver as the Test Connect timeout - could shorten a probe but never
lengthen it (Galaxy's 30 s default was silently 10 s). TestConnectBudget reads
the root ProbeTimeoutSeconds from the merged config at click time, clamped to
the actor's [1, 60] s, falling back to TimeoutSeconds. DeviceModal (the only
host) needs no change. The Galaxy/OpcUaClient form hints are reworded.

The 30 s result-clear timer moves from System.Timers.Timer + an async void
Elapsed lambda to System.Threading.Timer, drained in DisposeAsync, with a
generation so a superseded fire cannot clear a newer result.

Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 17:45:39 -04:00
Joseph Doherty b0959f697b perf(adminui): cache the modals' DynamicComponent parameter dictionaries (R04 H2)
DriverConfigModal, DeviceModal and RawTagModal built a new parameter dictionary
and new EventCallbacks every render. ParameterDictionaryCache reuses the
dictionary while the values it carries are unchanged and rebuilds it with the
current value when one changes (a build-once cache would strand edits); the
callbacks are created once. Blazor still re-sets an EventCallback-bearing
child's parameters per parent render, so the forms' _lastParsed guards stay.

Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 17:43:01 -04:00
Joseph Doherty 36e6ab590b perf(adminui): virtualize the CSV import grid; download exports from an endpoint (R04 P6)
The import review grid rendered every parsed row and re-scanned all rows three
times per render for its counts; RawCsvReviewView recomputes rows + counts once
per change and the grid renders through Virtualize. The export modal embedded the
whole CSV twice (textarea + base64 data: URI); it now shows a 50-line preview
and links to GET /api/raw/tags.csv (ConfigEditor, like /raw), which runs the same
RawTagCsvExport builder and sends it as an attachment.

Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 17:40:40 -04:00
Joseph Doherty da2578833d fix(adminui): Monaco text syncs on demand, diagnostics are sequenced, Problems list (D1)
R04:P1 - the editor no longer ships its full text JS->.NET on every keystroke. It reports
at blur, and ScriptEdit / the VirtualTag modal read the authoritative value with
MonacoEditor.GetValueAsync at Save (validation runs after the pull). The Blazor hub's
MaximumReceiveMessageSize is raised from 32 KB to 1 MB. The JS refuses a value that
would not fit instead of sending an oversize frame, and Save surfaces that refusal
rather than persisting stale source.

R04:P9 - diagnostics carry a generation counter and an AbortController. Every edit aborts
the in-flight request, and only the response for the current text is applied.

R04:S2 - the always-empty inlay-hints provider, endpoint, service method and contracts
are removed.

R04:S3 - MarkersChanged is typed (DiagnosticMarker) and feeds a new ScriptProblemsList.
Clicking a problem calls RevealLineAsync. Markers cross to .NET only when a list
subscribes.

Refs #745

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 17:38:56 -04:00
Joseph Doherty 2a788ed8ac perf(adminui): RawTree renders a flat Virtualize list, pages 500 per level, caches menus (R04 P5)
The recursive RenderNode rendered every row of an expanded device, and built a
fresh context-menu list + closures per node per render. RawTreeRows flattens the
expanded tree (explicit stack) into rows rendered by one Virtualize; each level
shows 500 children, then a 'Show more' row. RawNodeMenuCache keys menus weakly
on the node instance and rebuilds on a picker-mode or Enabled change.

Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 17:33:45 -04:00
Joseph Doherty 82380d2bee Merge lane G1: OpcUaClient + MTConnect driver remediation (#743)
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 17:16:20 -04:00
Joseph Doherty 92749402b5 fix(modbus): review r3 - one address authority (ModbusTagAddressResolution)
N3: a keyless blob carrying the addressResolved marker was served from its
string by the driver but saved as HR[0] by the editor model / CSV path. The
precedence rule now lives in ONE pure resolver in Driver.Modbus.Contracts
(ModbusTagAddressResolution.Classify/Resolve): keys when region+address are
both present, else a string-only addressString resolved with the driver's
family (refused when it cannot parse), else refused. The marker never decides.

Consumers that now ask it instead of restating it: the driver's tag reader
(ModbusTagDefinitionFactory.FromTagConfig), the deploy gate (Inspect /
DescribeRejection), the editor model (AddressShape / IsStringOnly /
HasKeyAddress / ResolveWith, ToJson stamping, Validate), the CSV export cells
and the editor hint. The model writes keys only when it loaded them or a field
was authored - never defaults it did not resolve (also closes two divergences
the new matrix found: malformed-string+marker and non-string addressString were
saved as HR[0]).

One table-driven test (ModbusAddressAuthorityAgreementTests) runs 15 persisted
shapes through driver, deploy gate, model load/save/Validate and the real CSV
export->import under all four families; breaking the CSV export or reverting
the model to the marker rule fails it.

Minors: m1 CSV address cells keep the string+marker while it still describes
them (lossless unchanged round trip), drop it when contradicted, and the review
grid reports the drop; m2 the pre-lane test uses the real export residual; m3
unmarked string-only + typed-cell case added; m4 stale docs/summary and the
unused factory parameter removed.

Refs #741

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 16:46:21 -04:00
Joseph Doherty f0d807e7b7 fix(opcuaclient): review r0 minors m1-m10
- m1: the form hint now says ProbeTimeoutSeconds can only shorten Test Connect's
  10 s budget (passing the configured value as the button's budget is shared code -
  follow-up).
- m2: a superseded init no longer overwrites _options (generation-checked under
  _probeLock) or the cert-validation handler (handed back and published with the
  session; detached when not installed; a previous one detached on replace).
- m3: an ack none of whose condition ids resolves throws BadNodeIdUnknown + Warning.
- m4: an ack with no reply (transport failure / non-caller timeout) degrades.
- m5: no session before the gate is the same ServiceResultException(BadNotConnected).
- m6: the caller-cancelled-write deviation is documented.
- m7: a reply during a published outage advances the stamp but does not write
  Healthy; the keep-alive recovery ends the outage.
- m8: test for a non-caller OperationCanceledException write -> Degraded.
- m9: the browse session owns and disposes the user certificate it loaded
  (OpcUaUserIdentityFactory.LoadCertificate; a key-less cert is disposed before the
  throw); AdminUI-host certificate path documented.
- m10: a subscribe overtaken by a shutdown / re-init removes its half-built
  subscription instead of registering it (data and alarm).
- Sync Dispose drains each gate for 500 ms (was 2 s).

Refs #743

Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 16:42:29 -04:00
Joseph Doherty 0200619322 fix(modbus): review r2 - region+address keys always win; string-only means no keys
N2: pre-#741 rows carry region/address beside an addressString with no marker
(the old driver never read the string, the old model preserved it as an
unknown key). The r1 rule resolved those from the string - a silent remap or
BadNodeIdUnknown on upgrade. The driver now loads from region+address whenever
both are present (classic, editor-pinned, pre-lane); only a blob with NO keys
is string-only and resolved through the parser. This is safe because the model
no longer stamps keys onto a string-only tag. The model distinguishes
string-only / legacy-string-beside-keys / pinned, and the editor hint says so.
Test matrix over every persisted shape (keys only, pre-lane keys+string,
pre-lane stamped HR/0+string, string only, marker+keys, marker no keys) under
every family; the pre-lane row also through a model save and a CSV
export->import.
n5: a typed CSV address cell is an authored address - it drops addressString
and the marker (new CsvTypedColumn.ClearsKeys) instead of being discarded.
n6: Validate skips the region/dataType/byteOrder enum checks on a string-only
tag (the driver ignores them). n7: docs/v2/modbus-addressing.md restates the
key-presence rule.

Refs #741
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 16:23:37 -04:00
Joseph Doherty 1f82ecfc0d Merge commit '7feffc96' into remed/lane-Modbus 2026-10-22 16:19:17 -04:00
Joseph Doherty 3531834cce fix(modbus): review r1 - resolved address keys win only when the editor pinned them
N1: the m2 precedence trusted region/address whenever the keys were present,
but the AdminUI model stamps defaulted HoldingRegisters/0 on every save, so a
string-only tag (CSV import, or any editor toggle) silently became HR[0] -
reads AND writes. The resolved keys are now authoritative only when the editor
marked them ("addressResolved": true, written by Resolve); an unmarked
addressString is always resolved through the parser with the driver's family.
The model no longer stamps address fields for a string-only tag, CSV export
leaves its address cells blank, and the editor hint distinguishes string-only
from pinned tags. Tests: CSV import and editor save of a string-only tag, a
stamped-default blob, and the pinned positive control across families.
n1: docs/v2/modbus-addressing.md updated (FC23 opt-in, maxReadGap semantics,
coalescing scope, addressString/family rules, coil coercion, refusals).
n2: form round-trip tests for UseFC23ForMultiRegisterWrites /
DisableReadCoalescing. n4: the editor keeps unresolved address text when the
parent echoes back its own emit. n3: noted, no change.

Refs #741
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 16:06:02 -04:00
Joseph Doherty fd6ecf8293 fix(modbus): review r0 - FC23 opt-in, explicit maxReadGap 0 = off, legacy coil types load, one health writer
Coordinator rulings and Important findings from review r0:
1. FC23 is opt-in (new UseFC23ForMultiRegisterWrites, default false); a config
   without it - including the persisted "disableFC23": false every form-saved
   config carries - keeps the FC16 wire. DisableFC23 stays the hard kill-switch.
2. An explicit maxReadGap 0 means coalescing off again (its pre-lane meaning);
   the gap-8 default applies only to an absent key.
3. Coils/DiscreteInputs tags persisted with a register dataType (the old
   editor saved Int16) are coerced to Bool, never refused, with no deploy
   warning (a warning can be promoted to a blocking error). The editor loads
   them as Bool. Register region + Bool is still refused.
4. One comms-fault slot for reads and writes: a good read clears a write's
   transport fault and vice versa.
Minors: Dispose writes its own Unknown health (m1); persisted region/address
are authoritative over addressString so a Family change cannot remap a live
tag (m2); a malformed-but-delivered reply no longer fails the unit fast (m3);
a fresh socket published after a concurrent dispose is torn down (m4); the
editor resets address text per tag (m5); master merged (m6); the FC23 latch
log says re-init restores it (m7). Back-compat tests use the old persisted
JSON shapes and fail without the fixes.

Refs #741
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 15:55:32 -04:00
Joseph Doherty c12269c221 Merge commit '5135a036' into remed/lane-Modbus 2026-10-22 15:47:50 -04:00
Joseph Doherty 8a5b4434a4 Merge local master 5135a036 into remed/lane-AbLegacy
Refs #738
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 15:36:12 -04:00
Joseph Doherty 4a3d7a9361 feat(modbus): wire Family / MelsecSubFamily / DisableFC23, and the form's timing keys
U1: a tag's addressString (Modicon / mnemonic / DL205 V-memory / MELSEC
D-X-Y grammar) now resolves through ModbusAddressParser with the DRIVER's
Family and MelsecSubFamily at every initialize and is authoritative; the
family-unaware gates (deploy Inspect, AdminUI parse consult) accept what
some family resolves. The tag editor gets an address-text field that
resolves with the owning driver's family and persists both the string and
the resolved region/offset/type fields; a hand edit drops the string.
DisableFC23 now gates FC23: by default a 2..121-register holding write is
one FC23 write + read-back (a unit answering exception 01, or failing FC23 at
the transport, moves to FC16 for the rest of the generation); RTU framing
deframes the FC23 reply. Live-checked: the pymodbus fixture implements FC23.
Also: the AdminUI driver form serialises ModbusDriverOptions (TimeSpan
strings), which the factory DTO never read - every timing field on the form
was dead. The DTO now accepts both shapes (*Ms keys win).

Refs #741
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 15:35:58 -04:00
Joseph Doherty 2ef3cd0df2 feat(modbus): block-read coalescing on by default; coils/DI/BitInRegister/String fold
U2: MaxReadGap defaults to 8 and 0 now means adjacent-only rather than
off; a new DisableReadCoalescing switch (factory DTO + AdminUI form) turns it
off entirely. The planner also merges Coils/DiscreteInputs (FC01/FC02, gap in
bits), String scalars and BitInRegister tags - sixteen bit tags on one status
word are one FC03 instead of sixteen. Auto-prohibition and its re-probe /
bisection use the region's own function code (a coil range was re-probed
with FC04).

Refs #741
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 15:24:38 -04:00
Joseph Doherty efa040813a fix(ablegacy): coalesceReads absent means default; the form never pins it
Review r0 M9. The AdminUI form wrote coalesceReads:true on every save, pinning
today's default into every edited driver. AbLegacyDriverOptions.CoalesceReads
is now bool? (null = default ON, never serialised, same encoding as
Transport); the form omits the key when the switch is on and writes only an
explicit false. Persisted coalesceReads:true keeps loading as on.

Refs #738
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 15:24:30 -04:00
Joseph Doherty f827b3a134 fix(modbus): enforce region/type compatibility at the tag factory
P6: Coils/DiscreteInputs carry only Bool and register regions never Bool;
the factory (and so the deploy-gate Inspect and the AdminUI parse consult)
refuses a mismatch, and an absent dataType defaults per region (Bool for a
bit region). A HoldingRegisters+Bool tag used to throw out of the coalescing
planner and stall every tag of the subscription; the planner also skips any
incompatible pair defensively. The tag editor keeps the type compatible when
the region changes; the CLI refuses the pair up front. The array-write parity
test records the Coils divergence from DriverArrayWriteSupport (owned outside
this lane) as follow-up F1.

Refs #741
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 15:19:28 -04:00
Joseph Doherty 9c0f59a3ab Merge lane AbCip: AbCip driver remediation (#737)
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 15:09:58 -04:00
Joseph Doherty 20875ea939 Merge local master 0d49eaf7 into remed/lane-AbLegacy
Refs #738
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 15:06:32 -04:00
Joseph Doherty 530f4bdcd4 perf(ablegacy): coalesce adjacent N/B/F/L scalar reads into one PCCC request
Review 07 P7 (rest): adjacent words on one data file were never coalesced
(one round trip per tag) although the array path proves the transport can read
a span. Within a device pass, scalar tags on one N/B/F/L file within 8
elements of each other (block <= 200 data bytes, under the 236-byte typed-read
limit) now ride one multi-element read and are decoded from their offsets with
exactly the CLR types the single-tag path returns (int / float / bool).

Only shapes the single path decodes identically are coalesced: indirect,
sub-element, array, file-number-less (S:/I:/O:) and width-mismatched tags keep
the single path. A block the device refuses (an authored element past the end
of the file, a native PLC-5 non-N file) falls back to per-tag reads for its
members and its shape is remembered; a comms fault fails the members together.

New driver-config key coalesceReads (default true) with an AdminUI switch
(Razor change: AbLegacyDriverForm, for the Wave 4 live check). Adds an
env-gated ab_server parity case (coalesced == per-tag values).

Refs #738
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 14:41:20 -04:00
Joseph Doherty 4e9bd9d966 perf(abcip): native read window >= 64; cold waiters hold no window slot
P8: on the native transport the bounded-parallel read window is also the cap
on services per Multiple Service Packet (the device's shared scheduler packs
whatever is queued, within the connection's request/reply byte budget), so the
default 8 cost a 1000-tag controller ~125 round trips per poll instead of ~10.
The effective window (AbCipDriver.ReadWindow) is now max(64, option) when the
native tag factory serves reads; libplctag and injected factories keep the
option exactly. Option doc + AdminUI help text updated (Razor: Wave 4 live
check).

P7 addendum: a work item now takes its window slot only after its runtime
exists. A cold create queues on its device's single-flight connect gate, and
holding a slot there let one dead device's backoff-expiry attempt occupy the
whole window for a full Timeout, stalling every other device's reads.

Refs #737
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 14:19:38 -04:00
Joseph Doherty cc140593a0 fix(focas): refuse String on PMC/PARAM/MACRO in the factory, editor and CLI (R07:U8)
FocasDataType.String was authorable on any address, but no area read returns text: PMC
fell through to a byte read, PARAM to Int32, MACRO to a double, and the String node
received a boxed number at Good.

One rule, FocasTagDefinitionFactory.DescribeDataTypeMismatch, now backs every path:
- FromTagConfig rejects the pair, so the driver skips + reports it (BadNodeIdUnknown,
  never a Good number) and Inspect names the reason at deploy;
- FocasTagConfigModel.Validate refuses it on the typed fields;
- the AdminUI editor only offers String where it is readable and shows the rule's text
  inline (kept visible for a loaded blob that already carries it);
- the CLI read/subscribe/probe/write commands refuse it at the boundary.
String stays valid on FIXED: paths (Identity/Program name/mode text) and is ignored on
ALARM: tags; an unparseable address keeps its own diagnosis.

Razor change (FocasTagConfigEditor.razor) needs the Wave 4 live check.

Refs #740
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
2026-10-22 14:15:35 -04:00