GalaxyAlarmPriority, the one table live Galaxy alarms (MxAccessSeverityMapper)
and AVEVA A&E history (EventMapper, #886) map the AVEVA priority through, ranked
a higher number as more severe. AVEVA ranks priority 1 as the most urgent, so a
priority-1 alarm read 250 and a priority-999 system event 1000.
It now uses AVEVA's default priority ranges, most urgent first:
AVEVA priority AVEVA severity bucket OPC UA Severity
1-250 1 Critical Critical 1000
251-500 2 High High 750
501-750 3 Medium Medium 500
751-999 4 Low Low 250
(history only) 0 not an alarm - 1
Out-of-range priorities clamp (<= 0 Critical, > 999 Low). Evidence, vd03
Runtime.dbo.Events read-only: priority 1/100 alarms carry AVEVA severity 1,
400/500 severity 2, 600/700 severity 3, and every priority-999 System.* /
User.* row severity 0 with IsAlarm 0.
- Live and history now use the same number. GalaxyDriver passes the table's
exact value as AlarmEventArgs.OpcUaSeverity. Before, it passed only the bucket,
which NativeAlarmProjector re-mapped through its generic 200/500/700/900
ladder, so live and history disagreed even before the direction fix.
- History: a row whose AVEVA severity is 0 (System.Start/Stop/Deploy,
User.Write...) is not an alarm and reads Severity 1, below every alarm band.
For alarms AVEVA's 1-4 severity is still never the value: the live feed
carries only the priority, so it cannot use it, and history must agree.
- Docs: docs/Historian.md gains "Galaxy alarm priority -> Severity
(lmxopcua#887)"; docs/AlarmTracking.md updated.
- Live re-run of the #801/#886 harness against vd03 HistorianGateway
ea9f21c (read-only, network-only): 224 of 233 cases identical to the #886
run, the 9 others differ only in Severity (priority-700 alarm rows 750 ->
500, 19 system/user events 1000 -> 1). Record: aveva-history-801.md
"#887 re-run", report aveva-gate-sdk2-887.json.gz.
Client-visible: every OPC UA client that ranks or filters Galaxy alarms by
Severity sees the order reversed (live and HistoryReadEvents). ScadaBridge has
no code that depends on the old values; its own mixed severity directions are
ScadaBridge#129.
Tests updated because they pinned the inverted table:
- Driver.Galaxy.Tests MxAccessSeverityMapperTests (rewritten: edges 1/250/251/
500/501/750/751/999, 0/-100/int.MinValue/1000/int.MaxValue clamps,
monotonic-decreasing sweep, equals GalaxyAlarmPriority for -2..1001)
- Driver.Galaxy.Tests GatewayGalaxyAlarmFeedTests (750 and 600 -> Medium)
- Driver.Historian.Gateway.Tests EventMapperTests (band table, priority 999
-> 250, 1 -> 1000; system events -> 1)
- OpcUaServer.IntegrationTests GalaxyEquipmentEventHistoryWireTests (700 ->
500, 100 -> 1000, System.Stop -> 1; the fake now stores AVEVA's real 0-4
severity)
New tests:
- Runtime.Tests NativeAlarmRestatementEndToEndTests
.Galaxy_live_condition_severity_is_the_AVEVA_priority_band (8 rows: the real
feed -> real GalaxyDriver -> host -> projector; the same rows EventMapperTests
pins on the history path)
- EventMapperTests.Aveva_severity_zero_marks_an_event_that_is_not_an_alarm
(5 rows, incl. the priority-999 alarm positive control)
- GalaxyDriverAlarmSourceTests: OpcUaSeverity passes through
Mutation check, 8 mutants, all killed: the pre-#887 inverted table; the
driver dropping OpcUaSeverity; no not-an-alarm rule; each of the three band
edges off by one; history ignoring priority; a missing AVEVA severity read
as 0.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
Adds GatewayGalaxyStreamAttachedAckLiveTests (skip-gated on MXGW_ENDPOINT +
GALAXY_MXGW_API_KEY, like the other gateway live tests). Proves what the unit
suite cannot: the request flag reaches a real gateway and the sentinel comes back.
- live session advertises stream-events-attached-ack; GatewayGalaxySubscriber reports it
- raw stream: sentinel is the first message when requested (family Unspecified,
worker_sequence 0, live_after 0) and never sent when not requested (control,
with a data event as the positive control)
- real GalaxyDriver + EventPump + GatewayGalaxySubscriber behind a pass-through
recorder: exactly one sentinel, ack observed before the first SubscribeBulk,
pump StreamAttached completed, sentinel never dispatched nor counted as
received (galaxy.events.stream_attached=1, received == non-sentinel events),
no missing-ack warning within the production 1 s budget, and the static
attribute TestMachine_002.Tagname delivers its initial value
- control: a subscriber that opts out gets no sentinel and the pump never
reports one, while the #865 fallback still delivers
Run 2026-11-12 against windev 10.100.0.48:5120 (mxaccessgw 447070a5): 4/4.
Mutation checks, each caught: subscriber not requesting the ack (sentinel
count 0); driver skipping the ack wait (wire order became stream | subscribe |
ack, 2/2 runs, so the race is real on a live gateway); pump not intercepting
the sentinel (received=2 vs 1 non-sentinel).
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
mxaccessgw#227 (Contracts/Client 0.4.0) adds an opt-in attach acknowledgement on
StreamEvents: a StreamAttached sentinel MxEvent sent first, only after the
stream's subscriber is registered on the session. This closes the #865 attach
race that waiting for "stream requested" only narrowed.
- Bump vendored MxGateway.Client/Contracts 0.3.0 -> 0.4.0 (nuget-packages/,
pulled from the Gitea feed; local-mxgw stays the mapped source).
- IGalaxySubscriber.SupportsStreamAttachedAck (default false, so fakes and older
seams keep the fallback); GatewayGalaxySubscriber reads it from the live
session's capabilities (stream-events-attached-ack) and passes
emitStreamAttached accordingly; TracedGalaxySubscriber forwards it.
- EventPump: records AttachAckExpected before the stream opens (published
before StreamRequested completes); intercepts ev.StreamAttached ahead of the
ReplayGap check - completes StreamAttached and continues: never dispatched,
never counted as received, never a resume cursor (worker_sequence 0). The
signal also completes when the loop ends so no waiter hangs. One pump = one
stream, so a reconnect's new pump has a fresh signal. New counter
galaxy.events.stream_attached.
- AwaitCurrentEventStreamAsync: with the capability, waits on StreamAttached
within the same StreamRequestWait budget (1 s); a missing ack logs a
rate-limited Warning and proceeds instead of hanging. Without the capability
the old StreamRequested wait is the fallback.
Tests (StreamAttachedAckTests, 6): ack-gated subscribe gets its initial value;
capability absent uses the fallback; missing ack times out with a warning; the
sentinel is never dispatched; a dead stream releases ack waiters; reconnect
gives each stream a fresh signal. With the ack wait skipped, 3 of them fail.
Claude-Session: https://claude.ai/code/session_01GT67ACmpMR7b9LGRPLijMi
The rule fix itself landed in 1a08b4f7 (detail-0 failure rows route on
category); its test only exercised raw_detected_by = 3. Add per-source
coverage for every MxStatusSource value mxaccessgw's MapSource emits
(-1, 0..5, and an out-of-range value) across the failure categories, plus
the live-captured shape the old rule got wrong (OperationalError detected
by the responding automation object, mxaccessgw docs/AlarmProbeFindings.md)
and a RequestingLmx CommunicationError positive control. All 10 new cases
fail against the old 'detail 0 && raw_detected_by != 0 => comms' rule.
Comment in FromMxStatus now cites MapSource and says why NMX (2/3) is not
a transport signal. Item 1 (Warning/Pending) stays open pending a capture.
Co-Authored-By: Claude <noreply@anthropic.com>
Every raw detected_by value names an MXAccess layer (requesting/responding
LMX, NMX, automation object); the gateway's own failures arrive as
ProtocolStatus. The 'non-zero source = transport failure' rule made a failure
the responding object detected a comms error. Item 1 of #872 (Warning/Pending
categories) stays open pending a captured row.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
The gateway fills Statuses on every data change (live OnDataChange, value-cache
replay and session snapshot all carry Quality too), and EventPump used the status
row whenever one was present, so Quality was never read: an off-scan, Bad or
Uncertain attribute with an OK status row was published Good. A failure status
row still wins; otherwise the quality byte grades the value (legacy parity:
quality >= 192 Good).
Live, read-only on VD03 (DEV): healthy ScanState and _TestArea attributes stay
Good (0x00000000) via quality 192; the stopped JoePlatform/JoeAppEngine ScanState
now publish BadCommunicationError (0x80050000) instead of generic Bad, with no
"unrecognised quality byte" warning.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
The gateway copies MXSTATUS_PROXY.detail verbatim, so a failure row's detail is
always an MxStatusDetail code. FromMxStatus routed any detail <= 0xFF through the
OPC DA quality table: MX_E_PlatformCommunicationError (2) on a stopped platform's
ScanState logged "Unrecognised MXAccess quality byte 0x02" and published generic
Bad (VD03 live capture), MX_E_InvalidObjectId (8) became BadNotConnected,
MX_E_Overflow (20) BadCommunicationError, and a detail in the Uncertain band
published Uncertain for a failure.
Every non-zero detail now maps per the gateway.md vocabulary (timeout,
communication, configuration, type, range, access, initialising), then by
category; the category-fallback warning logs once per (detail, category).
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
Adds an escalated-stream-fault test seam and a test: the live pump's fault
escalates (positive controls before and after), a superseded pump's late
fault after a reopen does not; the absence is asserted only once both
pumps' callbacks are known to have run (HasEnded). Verified to fail with
the filter disabled. The filter's comment now says the identity check does
the work and warns about a future session bump while Healthy.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
ReconnectSupervisor swallowed a transport failure reported while Replaying,
so a restarted event stream refused/ended a round trip after the replay
began still let the replay go Healthy over a dead stream (and the next
advise's re-report restarted at attempt 1 with no backoff). A failure
reported during Replaying is now remembered and turns that attempt's
success into a retry with backoff. ReplayAsync's synchronous dead-pump
throw yields to a teardown's cancellation.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
- Start the ack confirmation with Task.Run + ConfigureAwait(false) so it never
depends on the ReceiveAsync handler's ActorTaskScheduler (the PostStop
abandon-and-revert report must run after the actor stopped).
- DriverInstanceActorAckConfirmationTests: a confirmation that faults after the
handler returned is reported; one pending at actor stop is reported; a
confirmed ack reports nothing (positive control).
- Deterministic tracker matching test (Raise/Clear/Retrigger/other alarm do not
confirm; case-insensitive match does).
- AdminUI min/max on the confirm-timeout field; Galaxy.md documents the
reconnect, UNACK_RTN-as-Clear and RPC-budget limits.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
- ReplayAsync fails when its restarted pump's stream has already ended, so
the supervisor backs off and stays Degraded instead of going Healthy over
a dead stream (whose next advise re-report restarted at attempt 1 with no
backoff - a tight reconnect loop).
- ReconnectSupervisor.AttemptInProgress (reopen through replay); advises
wait for a stale pump's replacement only while an attempt is running, not
for a whole backoff (the state still reads Reopening/Replaying there).
- ReconnectSupervisor: _disposed is set under the state lock and re-checked
inside ReportTransportFailure, so a late report cannot start a recovery
loop that StopAsync already missed.
- EventPump.HasEnded is a flag set before StreamRequested is released, and
a stream that ends/faults on its first MoveNext is marked ended first.
- SubscriptionRegistry fast path: a miss now falls through to the locked
path (lookup + session + window check atomically) instead of a lock-free
re-lookup.
- Tests: replay over an immediately-ending stream fails; AttemptInProgress
across attempt/backoff; ReportTransportFailure after stop; the
reopen-window test uses a generous wait bound.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
mxaccessgw answers AcknowledgeAlarm OK both when the AckMsg write was
applied and when it was only sent (no OnWriteComplete; the reply then
carries a diagnostic). EvaluateReply treated both as success, so the H6
live gate saw a condition go Acknowledged while Galaxy never applied it.
- EvaluateReply returns Applied (no diagnostic) or Unconfirmed (diagnostic)
and logs the gateway diagnostic on every branch that carries one.
- GalaxyAckConfirmationTracker watches the alarm feed from before the RPC
and, for an unconfirmed reply, waits up to AlarmAck.ConfirmTimeoutMs
(default 10 s, 0 = old behaviour) for an Acknowledge/ActiveAcknowledged
transition; on timeout it refuses (BadTimeout + diagnostic).
- New optional IAlarmAcknowledgeConfirmation: DriverInstanceActor awaits it
after AcknowledgeAsync, off its mailbox and outside the resilience
pipeline; a failure is the existing #760 AlarmAckFailed revert.
- AdminUI Galaxy form carries the new knob; docs updated.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
- StreamRequestWait 1 s (under Tier-A Read 2 s / Subscribe 5 s budgets) and
a stale pump is only waited on while the supervisor is reopening or
replaying (or a restart is underway); in a reconnect backoff the advise
proceeds at once. The no-stream log is a rate-limited Warning while
Healthy, Debug otherwise.
- A current-session pump whose loop has ended is not a stream: if the
supervisor already reports Healthy (its fault was swallowed while it was
recovering) the failure is re-reported to start a new cycle.
- Subscribe/Read no longer start the pump directly (only
AwaitCurrentEventStreamAsync does, honouring the replay restart flag);
the teardown refusal is an explicit ThrowIfRuntimeStopping.
- SubscriptionRegistry.ResolveOrPark fast path: the handle lookup and the
open-window check were not atomic, so a subscribe that registered the
handle and closed its window in between got its initial value dropped as
stale (found by a stress run: the first event of a bulk advise lost). It
re-looks-up before declaring stale. Deterministic test via a seam.
- Tests: first Read on a fresh driver, replay of a data subscription.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
Round 1 replaced a stale-session pump from any advise path and disposed the
old one in the background; that could start a second stream while the old
one still held the gateway's single-subscriber slot, and a kept
current-session pump could be dead with no fault re-reported.
- EnsureEventPumpStarted reuses again; only ReplayAsync restarts the pump.
RestartEventPumpForReplay keeps a current-session pump only while its loop
is running (EventPump.HasEnded), and flags the restart so no advise path
starts a competing pump in the dispose gap.
- AwaitCurrentEventStreamAsync (bounded by StreamRequestWait) starts a pump
only when none exists, WAITS for the replay while the pump is stale or
restarting, waits for StreamRequested, and returns the session it verified.
SubscribeAsync (per #861 attempt), read-via-subscribe and the probe hook
issue and fence the advise under that session, so a reconnect after the
check is caught as a straddle and retried.
- Read: a deadline (not caller) cancel during the wait falls through to
per-ref results.
- Tests: reopen-window probe test now asserts the advise waits for the
replay's single new stream; first Subscribe/Read wait for the stream; the
fencing tests that advise in the window use a short wait bound; the
production-path seed test uses an empty galaxy (a real probe advise now
starts a stream against the fake endpoint).
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
- EnsureEventPumpStarted replaces a pump created for an older registry
session (the reopen -> replay window still held the dead session's pump,
so an advise there lost its initial value and the replay skipped it);
RestartEventPumpForReplay keeps a pump already on the current session.
- SubscribeAsync, read-via-subscribe and ReplayAsync also await the
bounded StreamRequested wait before advising, not just the probes.
- TryEnsureEventPumpStarted tolerates a teardown flipping _runtimeStopping
mid-check; the probe hook honours an already-cancelled seed token.
- StreamRequested is documented as narrowing, not closing, the attach race.
- Tests: reopen-window probe test, EventPump.StreamRequested tests, and the
FixRound1 fresh-pump assertion now waits on a positive control.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
The gateway's StreamEvents with after_worker_sequence = 0 is a fresh stream
and never replays, and the event pump started only on the first
Read/Subscribe, so platform ScanState probes advised before then lost their
initial value (and a driver with no authored tags never got any host status).
PerPlatformProbeWatcher now awaits an ensure-event-stream hook before every
probe SubscribeBulk (seed, discover sync, reconnect ResubscribeStaleAsync).
The driver's hook starts the pump (refused while a teardown is in progress)
and waits, bounded, on the new EventPump.StreamRequested signal - completed
once the stream loop's first MoveNext has issued the StreamEvents RPC, or
when the loop ends - so the advise never precedes the stream request.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
With Reconnect.ReplayOnSessionLost=false a recreated gateway session carries none of
the old advises, so every pre-reconnect subscription went silently deaf: nodes kept
their last value as Good and health returned to Healthy (only a Warning log).
ReplayAsync now records the stranded subscriptions and publishes BadNoCommunication
(StatusCodeMap.BadNoCommunication, 0x80310000; value null — no driver value cache)
for every tag of each, straight to OnDataChange so LastSuccessfulRead is not stamped.
GetHealth reports Degraded naming the setting while any stranded subscription is
still registered; it clears on UnsubscribeAsync (the host's re-subscribe path) or
runtime teardown, and pruned ids never pin it. A subscribe after the reconnect is an
ordinary new-session subscription. With nothing else flowing, the comms-loss
watchdog re-initializes the driver after 90 s (a delayed replay).
Tests: Runtime/StrandedSubscriptionTests (6). Docs: drivers/Galaxy.md, which also
no longer claims the replay uses the gateway's ReplaySubscriptions RPC.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
BLOCKER: the reconnect replay chose work from the registry entries' sessions,
but ONE registry entry holds every probe handle and any probe publish on the
new session (a seed in the reopen→replay gap, or the straddle retry) re-stamps
it as current — the replay then skipped the probe watcher and the old
platforms stayed bound to handle 0 (host status frozen); a publish after the
snapshot made it re-subscribe everything (double advise, leaked handle).
ReplayAsync now excludes the probe entry from its snapshot and calls the new
PerPlatformProbeWatcher.ResubscribeStaleAsync on every reconnect, which
re-subscribes exactly the platforms whose ProbeHandle.Session predates the
current session. The replay-gap path keeps ResubscribeAsync (all platforms).
Also: ClearRegistry (teardown) starts a new registry session, so a late
PurgeParked from a teardown-orphaned call cannot reach the next runtime's
parked values; the read path's unused pump local is gone (call kept).
Tests go through the driver's reopen/replay: the probe old-session-number test
is rewritten that way, plus the seed-in-the-gap scenario (only P and Q are
re-subscribed, R keeps its new-session handle, all three resolve). Both checked
red with the probe replay removed / re-subscribing all platforms.
Refs #859, #861.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
B-1: the subscribe-once read's cleanup unsubscribes what the registry holds at
removal (the replay may have rebound it to new-session handles), not its
original bindings; nothing when the entry still holds dead old-session
handles. Found while testing it: reads were attached to the pump INSTANCE, so
a read across a reconnect's pump restart never saw the replayed value — reads
now listen on a driver-level ReadDataChange raised for whichever pump is live.
I-A: PerPlatformProbeWatcher records the registry session with each probe
handle. Publishing goes through the new fenced TryUpsert and binds only
current-session handles; removal/stop unsubscribe and purge only those; a
seed reply that straddled a reconnect records nothing and is re-issued (max 3).
I-B: PurgeParked takes the session captured BEFORE the unsubscribe RPC and is
a no-op under the park gate if the session changed.
I-C: ReopenAsync starts a new registry session before AND after the gateway
session swap; ReplayAsync does so only when no reopen ran (injected subscriber
/ tests) and replays only subscriptions still holding older-session handles,
so a subscribe issued after the swap is live and not double-advised.
P-1: ReplayAsync restarts the pump before any early return (no entries used to
leave the dead pump in place). P-2: ReplayOnSessionLost=false logs a Warning;
misleading comment about gateway-side replay fixed.
M-a: TryRebind returns BindOutcome; UnknownId releases the handles just
advised for a subscription removed mid-replay. M-b: the replay/re-snapshot
pass reads the session once and stops if it changes. M-c: parked entries drop
their MxEvent when they leave the parked set. M-d (retry a straddled read)
not done.
Tests (TestWait) for each, each checked red against a mutation of its fix.
Refs #859, #861.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
I-2: unclaimed parked events are trimmed by window sequence. Each window gets a
monotonically increasing sequence at Begin, each parked event is stamped with
the newest one, and on every End events stamped before the oldest open
window's sequence are dropped (amortised O(1) via a park-order queue). Under
concurrent reads the open count rarely hit 0, so trailing events used to pile
up to the bound and push genuine early values into overflow.
I-1 / #861: SubscriptionRegistry.StartNewSession() — called FIRST in
ReplayAsync on every reconnect — clears held events, invalidates the reverse
map (subscriptions kept) and bumps a session number. New-session events whose
number an old binding still held now park until the replay's per-subscription
Rebind promotes them, instead of resolving to the wrong tag. TryRegister /
TryRebind refuse a stale session atomically under the park gate: a
SubscribeAsync whose reply straddled a reconnect is re-issued on the new
session (max 3 attempts), a subscribe-once read returns BadCommunicationError,
ResubscribeAllAsync stops if the session changes again. Old-session handle
numbers are never unsubscribed (Remove reports whether the entry belongs to
the current session; the read's late-reply path checks too), and an old
session's pump can no longer resolve through the map (fast path checks the
session).
I-3 (interim): a completed UnsubscribeBulk purges events parked for its
handles (driver + probe watcher). Full fix needs a worker sequence on the
SubscribeBulk reply (mxaccessgw, optional) — documented.
M-1: a resolved handle with a stranded parked list promotes it and resolves
the live event (never parks it). M-2: ResolveOrPark returns the ready events
to replay first, one gate acquisition per event while anything is held.
M-3: SubscribeAsync/read dispose the window before the orphan-release RPC.
M-5: ResolveOrPark remarks document the single-dispatching-pump invariant.
Tests (TestWait): overlapping windows don't accumulate, purge, stranded list,
session fence + map invalidation, stale-session registration refused,
end-to-end replay with swapped handle numbers and event-before-reply,
subscribe and read straddling a reconnect, read deadline closes its window.
Each was checked red against a mutation of the fix it pins.
Refs #859, #861.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
1. ReadAsync (subscribe-once) now opens the early-event window around its
SubscribeBulk + registration; an initial value that overtook the reply was
dropped and the read returned BadTimeout.
2. Register/Rebind write the reverse map and promote parked events in ONE
critical section under the park gate, and ResolveOrPark resolves under that
gate whenever anything is held (lock-free fast path only when nothing is),
so a later live event can no longer overtake the parked initial value. A
resolved handle that still holds a parked list queues behind it.
3. Held events are fenced by a session epoch: each new EventPump calls
StartNewEpoch(), discarding parked AND promoted-but-unreplayed events; an
older pump can neither park nor replay. Item-handle reuse across a reconnect
can no longer put an old-session value on a new tag.
4. ResubscribeAllAsync opens one window per subscription, not across the whole
replay.
5. Promoted-but-unreplayed (ready) events count toward MaxParkedEvents.
6. Begin/End of a window run under the park gate, so N->0 discard and 0->1
open are atomic (no inherited leftovers).
Documented that ParkedEventsReady may run under _registryGate/_syncLock and
relies on the channel's AllowSynchronousContinuations=false.
Tests use TestWait (#858); each new test was checked red against a mutation
of the fix it pins.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
mxaccessgw gives no reply-before-event ordering: the worker completes the STA
command via a RunContinuationsAsynchronously TCS, so the reply is framed on a
thread-pool continuation while the STA already pumps the OnDataChange Advise
queued (drained/framed by a separate loop), and the reply (unary Invoke) and
the event (StreamEvents) are separate HTTP/2 streams. The driver then also
registers handles concurrently with the pump's dispatch loop. MXAccess's
initial value could therefore be dropped as "stale after unsubscribe",
leaving the node at its pre-subscribe value until the next change.
SubscriptionRegistry gains an early-event window: every SubscribeBulk call
site (SubscribeAsync, ResubscribeAllAsync, PerPlatformProbeWatcher) opens
BeginPendingSubscribe() before the RPC and closes it after registering.
Inside the window unknown-handle events are parked (bounded, 100k); the
Register/Rebind that binds a handle promotes them, and the EventPump replays
them on its single dispatch thread before any later event for that handle
(woken by a sentinel when no further event arrives). Closing the last window
discards unclaimed events, so the stale drop is unchanged outside it.
New counters galaxy.events.early_{parked,replayed,overflow}.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
Under heavy parallel load (14 concurrent test processes + 14 CPU burners, with
DOTNET_ThreadPool_ForceMinWorkerThreads=1 as the reproducer) the Galaxy tests
with 1-3 s fixed waits failed 16/70 runs. Every failure was a background loop
started with Task.Run (alarm feed, DeployWatcher, EventPump, ReconnectSupervisor)
not being SCHEDULED within the ceiling - e.g. DeployWatcher's stream had not even
been opened after 2 s. No production race: the code under test was checked for
each (alarm feed dispatch is synchronous in-order, DeployWatcher/ReconnectSupervisor
state is lock- or loop-local, subscribe registers before returning).
- New shared TestWait (UntilAsync / ForAsync / HealthyAsync): 30 s presence
ceiling, failure reports elapsed ms + an observed-state snapshot (#856 shape;
GalaxyDriverFixRound1Tests.WaitUntilAsync now delegates to it).
- Converted the short waits in GatewayGalaxyAlarmFeedTests, DeployWatcherTests,
GalaxyDriverSubscribeTests, GalaxyDriverRawPathKeyingTests (its WaitForAsync
never threw on timeout), EventPumpStreamFaultTests, EventPumpReplayGapTests,
ReconnectSupervisorTests; FixRound2 InitBudget 2 s -> 10 s (the parked fetch
never completes, so any finite bound keeps the verdict).
- Absence by short sleep replaced with positive controls: DeployWatcher bootstrap
and same-deploy-time (follow with a real change, assert exactly that one raise -
verified red when suppression is removed), subscribe failed-tag / unsubscribed
handle (follow with a live handle's event), faulted pump (wait for its
onStreamFault instead of 100 ms).
- Fixed sleeps that raced scheduling: subscribe-once read tests wait for the
read's registration (TrackedSubscriptionCountForTests) instead of 50 ms;
supervisor Dispose test waits for reopen entry instead of 50 ms; the
already-Healthy WaitForHealthy test asserts synchronous completion instead of a
wall-clock bound. FakeSubscriber.Map is now a ConcurrentDictionary.
Loaded run (14 parallel x 5, 14 burners, ForceMinWorkerThreads=1):
before 16/70 failed runs; after 0/350 (70 + 210 + 70). Without the thread-pool
override: 0/70 before and after on this host. Serial: 472 passed, 8 skipped.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
Found while load-verifying #856: ShutdownAsync_cancels_the_event_stream_and_releases_the_pump
timed out 7/700 under parallel load. The fake's StreamCancelled was set by a
CancellationToken registration scoped by `using` inside the async iterator.
On Cancel() the newer ReadAllAsync registration runs first and resumes the
iterator on a pool thread, whose `using` can dispose our registration while
Cancel() is still walking the callback list - so it never runs. Signal from
the iterator's finally (when the token is cancelled) instead, which also
proves the stream actually ended. 0/700 after.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
PerPlatformProbeWatcher records a platform's handle and publishes the probe
binding into the driver registry as one step under _syncLock, but
WatchedPlatforms read the handle map lock-free - so it could report a
platform one step ahead of the registry Upsert. A ScanState event raised in
that window was dispatched by the EventPump, missed ResolveSubscribers and
was dropped as "stale after unsubscribe", leaving the host status empty.
That is the #856 flake: A_fetch_completing_after_init_populates_host_statuses
waited for WatchedPlatforms, emitted ScanState, and timed out at 10 s on the
final Running wait. Reproduced 11/700 (28 parallel runners x 25 + 14 CPU
burners), every failure at that step with the binding present by the time of
diagnosis and hostStatuses=[] - i.e. the event was dropped. 0/1400 after.
WatchedPlatforms now reads under _syncLock (test seam only; the dispatch path
already checks the map after the registry, the safe order). New
PerPlatformProbeWatcherVisibilityTests spins a reader on another thread and
asserts the registry entry exists the moment the platform is visible
(old code: torn in 1691/2000 iterations). WaitUntilAsync gains a describe
overload; the #856 test's waits now report elapsed time and the observed
seed/binding/pump/host-status chain on timeout.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
A Designer could point a Galaxy / OpcUaClient endpoint at a host they control,
set a credential field to any reference the node can resolve
(env:ConnectionStrings__ConfigDb, env:ServerHistorian__ApiKey, secret:<any>,
Galaxy file:<any path>) and click Test Connect / live browse; the node resolved
the value and sent it to that host.
One shared rule in Core.Abstractions (CredentialReferences +
DriverCredentialPolicy) generalises the #803 Heidenhain namespace:
- Galaxy: secret:galaxy/... | secret:otopcua/galaxy/... | env:OTOPCUA_GALAXY_... |
legacy env:GALAXY_MXGW_...; file: refused; dev:/literal API key unchanged.
- OpcUaClient: secret:opcuaclient/... | env:OTOPCUA_OPCUACLIENT_...; literals unchanged.
- Heidenhain adopts the shared parser/resolver (namespace unchanged).
Enforced at the AdminUI save path (DriverConfigSaveGate), the deploy gate
(CredentialReferenceDeployChecks, code CredentialReferenceOutOfScope), Test
Connect (AdminOperationsActor, before any probe), live browse
(BrowserSessionService, before any browser) and again at resolve time in every
driver/browser (fail closed, before any store/env read).
Co-Authored-By: Claude <noreply@anthropic.com>
Item 3 of #765. A keyed (API-key) session whose key had no Galaxy ack identity
got Good and then a revert, because whether the key has an identity lives in
the Secrets store, which must not be read under the SDK lock.
GalaxyAckIdentityDirectory (Driver.Galaxy) keeps a node-wide set of the key ids
that have a galaxy-ack-user secret. It lists this node's Secrets store
(metadata only, nothing decrypted) and is read lock-free.
GalaxyDriver.GetAcknowledgeRefusal (IAlarmAcknowledgePreflight, published
through NativeAlarmAckPreflightView as in #760) now refuses a keyed session
whose key the directory reports Absent, when the driver has no fallback ack
account. A refusal also asks for a refresh.
Fails open: before the first refresh, once the snapshot is older than
StaleAfter, and from a signalled identity-secret change until the next
refresh, the lookup answers Unknown and the ack takes the old Good-then-revert
path.
Refresh: GalaxyAckIdentityRefreshService runs on driver nodes, every
Drivers:Galaxy:AckIdentityCache:RefreshIntervalSeconds (default 30;
StaleAfterSeconds 0 = three intervals; validated at start). It also refreshes
early on secret changes. The Secrets library has no change event, so
SecretsRegistration decorates ISecretCacheInvalidator, which is called by
AdminUI /api-keys, /admin/secrets and the replication appliers. API-key
changes need no event: a revoked key is already denied before the pre-check.
Tests: Galaxy.Tests GalaxyAckIdentityDirectoryTests (16) and Host.Tests
GalaxyAckIdentityCacheWiringTests (9). Seven separate mutations each turn at
least one test red: pre-check ignores the directory, factory drops it, no
invalidator decoration, no staleness check, no change-pending check, no
refresh on refusal, loop never wakes early.
Docs: Galaxy.md, AlarmTracking.md, Configuration.md, .claude/rules/alarms.md.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
Awaited deadline oracles get the runner token; sync-over-async tests made async;
nullable child models asserted via ShouldNotBeNull() return values; obsolete SDK
ctors replaced with the telemetry overloads; dead locals/fixture and the redundant
DI PackageReference removed. No suppressions.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
The native-ack path is fire-and-forget after the Part 9 Acknowledge returns, so
a Galaxy ack refused for lack of a credential (#749), or rejected by MXAccess,
left the client with Good and the condition showing Acknowledged while Galaxy
was never acked. Both options from the issue, layered:
1. Synchronous refusal for what the driver can decide without I/O. New optional
IAlarmAcknowledgePreflight (Core.Abstractions); GalaxyDriver refuses an
anonymous session when the driver has no AlarmAck fallback account.
DriverHostActor publishes a condition NodeId -> owning-driver snapshot into
NativeAlarmAckPreflightView (lock-free, volatile); the node manager's new
NativeAlarmAckPreflight seam, consulted after the authz and Primary gates,
returns BadUserAccessDenied with the reason - nothing routed, applied or
reported. A keyed session is not pre-checked (its identity lives in the
Secrets store, which must not be read under the SDK lock).
2. Revert for everything else. RouteAlarmAck carries the condition NodeId;
DriverInstanceActor replies AlarmAckFailed on a refusal, a backend failure,
a driver without an alarm source, or an ack dropped while connecting /
reconnecting. DriverHostActor re-projects the condition unacknowledged via
NativeAlarmProjector.TryRevertAcknowledge, but only while the local ack is
still pending - any driver transition projected since then wins. A disabled
or unspawned driver is not reverted (unchanged).
GatewayGalaxyAlarmAcknowledger now throws DriverOperationRefusedException on a
non-zero native hresult (wrong password, no ack permission) instead of only
warning, so that case reverts too; as a refusal it neither retries nor trips
the breaker.
Tests (each fails with its fix mutated out): projector revert/supersede,
DriverHostActor refused + failed ack -> unacked AlarmStateUpdate (successful
ack control), preflight view snapshot, node-manager preflight unit test,
over-the-wire ConditionMethodEventTests (BadUserAccessDenied, no route, no
event; positive control), Galaxy preflight + hresult refusal.
Docs: Galaxy.md, AlarmTracking.md, ScriptedAlarms.md, .claude/rules/alarms.md.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
mxaccessgw 488649c+ acknowledges by AuthenticateUser as the operator and
writing <alarm>.AckMsg, so AcknowledgeAlarmRequest now needs a real Galaxy
operator_user + operator_domain + operator_password. The OPC UA data plane is
API-key/anonymous and carries no Galaxy password, so the driver resolves the
account per ack:
1. the session's API key's Galaxy ack identity, set on AdminUI /apikeys and
held ONLY in the encrypted Secrets store
(otopcua/apikeys/<keyId>/galaxy-ack-{user,password}); a key with a user but
no password secret is refused, never silently downgraded;
2. else the driver instance's AlarmAck fallback account (DriverConfig
FallbackUser/FallbackDomain/FallbackPasswordSecretRef; secret:/${secret:}/
env:/file:/dev: only — a literal is refused);
3. else DriverOperationRefusedException: nothing is sent, never an empty
operator_user. Refusals are excluded from the resilience retry/breaker.
- Pins ZB.MOM.WW.MxGateway.Client/Contracts 0.2.1 -> 0.3.0 (vendored into
nuget-packages/ from the Gitea feed, per the local-mxgw source mapping).
- The session ApiKeyId (not a secret) rides NativeAlarmAck ->
RouteNativeAlarmAck -> RouteAlarmAck -> AlarmAcknowledgeRequest; the password
is resolved in the driver and never travels through actor messages.
- The OPC UA principal + key id are appended to the AckMsg comment
("[OPC UA: <principal>, key <id>]") and logged, so a shared fallback
account does not lose who acknowledged.
- Password never logged: GalaxyAckCredential.ToString omits it, the
acknowledger scrubs it from every gateway message it echoes and withholds
any exception that echoes it; audit rows carry only the key id.
- AdminUI: /apikeys "Ack identity" editor (set/remove; delete-key clears it),
Galaxy driver form gains the fallback section.
- Synchronous OPC UA status for a refusal is follow-up #760 (the native ack
path is fire-and-forget after the Part 9 method returns).
Tests: request mapping (password populated), password absent from logs and
exception text (mutation-checked), key-mapped / fallback / refused paths at
resolver and driver level, breaker non-trip, key-id propagation through node
manager and DriverHostActor, AdminUI service + form round-trip.
Closes#749
GalaxyTelemetryTests (ActivityListener) and GatewayGalaxyDataWriterFailClosedTests
(MeterListener, filtered only by meter and instrument name) observe every Galaxy span or
measurement in the process. They now run in a collection with parallelization disabled
(F-FU6), because a parallel driver test, or its background probe seed, polluted their counts.
The stream-cancel assertion in GalaxyDriverShutdownTests goes back to a bounded wait: the
instantaneous IsCompleted check introduced in round 1 was racy.
Refs #735
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Review fix round 2 for lane F:
- N1: the init platform seed no longer runs inline under the init token. Galaxy's Tier-A
Initialize budget is 5 s, and a cold gateway DiscoverHierarchy can spend all of it, so the
OperationCanceledException rethrow failed init, opened the Initialize breaker and cost a full
rebuild per retry. InitializeAsync now only resolves the platform source (no network) and
queues a background seed tied to a per-runtime CTS that the teardown cancels. A result that
lands after its runtime was torn down is discarded.
- N2: the seed worker serves the runtime that is live when each pass STARTS, so a request made
under a new runtime while a stale pass is in flight always gets a pass of its own.
- N3: SubscribeAsync and the subscribe-once read capture the runtime generation before
SubscribeBulk and register only if it is unchanged, atomically with the teardown's registry
Clear (_registryGate). On a mismatch they release the handles and fail the call. Re-subscribe
Rebind uses the same gate, and the production rebuild clears the registry unconditionally.
- PerPlatformProbeWatcher re-checks its stop after the SubscribeBulk await, atomically with
the record and publish. A pass that straddles StopAsync releases the handles it acquired
instead of writing the probe entry back into a cleared registry.
Refs #735
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The writer concurrency fake parks on its release signal (the 300 ms delay could release the
gate early on a starved pool), the supervisor test's cross-thread hold flag is Volatile, and
the EffectiveTimeout doc now states the 1 s floor the code and tests implement.
Refs #735
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Review fix round 1 for lane F:
- The ScanState probe watcher is seeded at InitializeAsync from a platform-only
DiscoverHierarchy query (IGalaxyPlatformSource / GatewayGalaxyPlatformSource over the owned
repository client) and re-seeded on every deploy-watcher rediscovery. The runtime never
calls DiscoverAsync on a live driver, so per-platform host status was unreachable in
production. A failed fetch logs a Warning and never fails init; re-seeds coalesce so a
deploy during an in-flight pass still gets a pass that starts after it.
- EnsureEventPumpStarted refuses while the runtime is stopping, BEFORE reusing the live pump
(that pump belongs to the dying subscriber), and the production rebuild disposes any stale
pump before wiring the new subscriber.
- TeardownRuntimeAsync closes the MX session under the caller's token linked with a 5 s
SessionCloseDeadline, so a blackholed gateway cannot hold DriverInstanceActor.PostStop for 30 s.
- A runtime generation counter, bumped by every teardown, is re-checked before each Rebind
in ResubscribeAllAsync, so a replay-gap re-snapshot that straddles a teardown cannot
resurrect handles into the cleared registry.
Refs #735
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The SDK's DisposeAsync closes with no token, i.e. under the 30 s DefaultCallTimeout, so a
blackholed gateway parked the driver's teardown for the whole of it. CloseAsync(ct) runs the
close under the caller's token, drops the channel on a cancelled/failed close (the gateway
reaps the session on its idle lease) and leaves the session re-openable. A close followed by
the final dispose closes the gateway session once.
Refs #735
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Review 2026-10-21 G-5, G-6, G-8 ("wire them all").
- G-5: GatewayGalaxyHierarchySource now pages the DiscoverHierarchy RPC
itself (DiscoverHierarchyRawAsync) at Repository.DiscoverPageSize. The
mxaccessgw client's typed DiscoverHierarchyAsync overloads hard-code a
5000-row page and DiscoverHierarchyOptions carries no page size, so the
authored knob reached nothing; the raw request takes page_size on the
wire, so it is honoured here (non-positive → 5000). The loop keeps the
client's repeated-page-token guard.
- G-6: GalaxyDriverProbe reads ProbeTimeoutSeconds from the config and
runs under min(caller budget, configured cap) — the knob can shorten a
probe, never extend it past the host's budget. The TCP preflight now
shares that deadline instead of hanging on the caller's token alone.
- G-8: GatewayGalaxyDataWriter runs a batch as one lane per distinct tag,
concurrently and bounded at 8 (MaxConcurrentWriteLanes); same-tag
writes keep their authored order inside one lane and results land at
their request's index. Acks stay serial by design.
- GalaxyDriverForm: help text now says what the two knobs actually do.
Refs #735
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Review 2026-10-21 G-4, G-7, G-11, G-10.
- G-4: PerPlatformProbeWatcher publishes its probe handles into the
driver's SubscriptionRegistry under the reserved ProbeSubscriptionId
(-1), so the EventPump's fan-out finally reaches the watcher — every
ScanState event used to be dropped as "stale after unsubscribe" and
per-platform host status never updated. ResubscribeAllAsync delegates
the reserved entry to the watcher's new ResubscribeAsync, so the probe
survives a reconnect; StopAsync removes the entry. Probe traffic is
routed by the reserved handle and never reaches the public OnDataChange.
The watcher is also built on the seam path (subscriber only), which is
what makes the wiring testable without a gateway.
- G-7: GalaxyDiscoverer.DiscoverAsync returns the hierarchy it fetched and
the driver selects its $WinPlatform/$AppEngine probe targets from that
same sweep instead of asking the gateway for the whole galaxy twice.
- G-11: OnPumpDataChange stamps LastSuccessfulRead from inbound stream
data, throttled (1 s default), so the comms-loss watchdog has honest
liveness evidence under a Degraded supervisor.
- G-10: an EventPump dispatch-loop exit that is not a cancellation now
reports a stream fault so the supervisor recreates the pump, instead of
leaving a deaf pump reporting Healthy.
Refs #735
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
GalaxyDriver.ShutdownAsync was a no-op: the MX session, both owned gRPC
channels, the EventPump, the alarm feed, the DeployWatcher, the probe
watcher and the reconnect supervisor were released only by DisposeAsync,
which the host never calls — one leaked gateway session per respawn,
removal and /raw browse, and a watchdog Shutdown→Initialize that neither
tore down nor rebuilt anything (review 2026-10-21 G-1, G-2, G-9, G-3).
- ShutdownAsync and DisposeAsync share one ordered TeardownRuntimeAsync
(supervisor first, then deploy/probe watchers, pump, alarm feed,
session, channels); owned seams are nulled so the next InitializeAsync
rebuilds; injected seams survive a shutdown and drop only on the final
dispose. Lifecycle calls are serialised behind a gate.
- A failed production connect releases its partial runtime (no orphaned
client per watchdog retry) and lands Faulted before and after.
- StartDeployWatcherAsync stops the previous watcher before starting a
replacement, and now starts on a production instance's FIRST
InitializeAsync (the old guard returned whenever discovery had not run
here, which on a runtime instance is always).
- ReconnectSupervisor releases each cycle's CancellationTokenSource when
its loop exits and gains an awaitable StopAsync; PerPlatformProbeWatcher
gains an awaitable StopAsync.
- EventPump treats any exception under cancellation as a clean stop, so a
teardown never wakes the supervisor.
- Internal seams for tests: an IGalaxyDeployWatchSource ctor parameter and
a session-open override forwarded to the owned GalaxyMxSession.
Refs #735
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
- AlarmTransitionKind.ActiveAcknowledged (appended): active AND acked applied as ONE projection.
Galaxy ActiveAcked snapshot entries and OpcUaClient inactive->(active,acked) use it; the
projector writes 'Activated' only if not already active, 'Acknowledged' only if not acked.
- AlarmEventArgs.IsRestatement (optional, default false): set only by Galaxy snapshot entries
and OpcUaClient first sight. A flagged Retrigger on an Active+unacked condition with the same
message and severity, or a flagged Clear on an inactive condition, writes no /alerts row.
- NativeAlarmProjector reports the history rows per transition; ForwardNativeAlarm writes one
row per entry. Unflagged sources (FOCAS/MTConnect/AbCip, live Galaxy) are unchanged.
- Tests: projector rules each with a must-write control; OpcUaClient transition table;
Galaxy feed/driver mapping; Galaxy + OpcUaClient end-to-end through DriverHostActor.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
MAJOR-1: a deploy that changes a driver's config respawns it, and the fresh instance's empty told
record re-sent Raise for every still-active alarm, un-acking acknowledged conditions and writing a
duplicate "Activated" alerts row. NativeAlarmProjector now treats Raise on an already-active
condition as a re-statement (keeps Acked; ForwardNativeAlarm skips the alerts row); only Retrigger
(or inactive->active) un-acks. Sources whose upstream ack state is authoritative send Retrigger for
an unacked re-statement: OpcUaClient on first sight (no prior told), Galaxy for an unacked active
snapshot entry. Runtime E2E drives a FRESH FOCAS driver after a redeploy and asserts the ack survives.
MAJOR-2: a failed FOCAS alarm read annotates each subscribed condition BadNoCommunication once per
outage (#626 quality-only path) with one Warning (MINOR-6), lifted to Good on recovery; failed alarm
reads degrade driver health with LastSuccessfulRead frozen (successful ones advance it), so an
alarm-only driver trips the #527 comms-loss watchdog.
MINOR-3 CLAUDE.md #630 bullet; MINOR-4 split line; MINOR-5 a non-empty cnc_rdalmmsg2 payload that
fits neither stride throws; MINOR-7 value-tag + parsed-address tables are built and swapped, never
cleared in place under the retained poll engine. Docs corrected (FOCAS.md, AlarmTracking.md, CLAUDE.md).
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
- v2-ci.yml: upload-artifact@v4 -> @v3 + continue-on-error (act_runner reports as GHES and
v4 refuses GHES, failing every run); runner-capacity diagnostic step; AKKA_TEST_TIMEFACTOR=3
on the test step.
- Runtime/ControlPlane harnesses: akka.test.timefactor from AKKA_TEST_TIMEFACTOR
(TestTimeFactor), single-expect-default 15s; ControlPlane gains PresenceBudget.
- Leaked spinner threads: the infinite-loop timeout tests (Calculation, Host.IntegrationTests
RoslynVirtualTagEvaluator, 3x Core.Scripting) pinned a core for the rest of the test process
(abandoned, never stopped). Now a bounded 5 s wall-clock spin; outer compile-inclusive bound 30 s.
- Real test races fixed: ScriptedAlarmEngine push-during-drain (Inactive is also the start
state + persist-before-update => wait for the Cleared save); DriverReconnectE2e (both nodes
host the driver; Created[] is last-writer-wins and ForceReconnect is a no-op while
Connecting); ControlPlaneStarterOrder (lost-race heal waited for a 60 s refresh tick).
- Fixed sleeps -> poll-for-condition: ReconnectSupervisor LastError, Modbus deadband steps
(wait for observed reads), Modbus dispose hygiene precondition, FOCAS probe-loop log.
- Short presence budgets -> PresenceBudget in the Runtime/ControlPlane tests seen failing on
Gitea; Calculation Settle 10 -> 30 s. No assertion removed, nothing skipped.
- infra/README.md §10 CI; stale TreatWarningsAsErrors comment in Directory.Build.props.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
MAJOR-1: the SDK skips TypeInfo.IsInstanceOfDataType on any node with an
OnWriteValue handler (every writable equipment node), and the node manager's
fail-fast treated numeric<->numeric as compatible, so a UInt32[] to a Galaxy
Int32 array matched MxValueEncoder's int[] arm by CLR covariance and was
written bit-reinterpreted with a Good result. EvaluateEquipmentWriteStructure
now matches an ARRAY write's element type exactly (Byte[]/ByteString the only
equivalence; Variant[]/object[] refused) -> BadTypeMismatch, nothing
dispatched. MxValueEncoder's int[]/long[] arms are exact-type guarded too, and
the Galaxy parity test's false "the SDK refuses" premise is corrected (the
UInt32/UInt64 exclusion is now the encoder's own answer). Scalar writes keep
numeric widening by decision: consumers write CLR-typed values (Double to a
Float node) and every driver's scalar encoder range-checks.
MINOR: Modbus row honours maxRegistersPerWrite (smallest of DriverConfig /
the tag's DeviceConfig, default 123) and FC15's 1968-coil ceiling, and
requires region + numeric address; Modbus/S7/Galaxy require isArray + integer
arrayLength >= 1 (Galaxy: an unbounded node would let a short write resize the
attribute); an array value to a scalar node is refused inline. Docs: Uns.md
array-write rules + upgrade note (ReadWrite array tags become client-writable
on first boot), Modbus.md, Galaxy.md.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
Array nodes were forced read-only for every driver. A new single authority,
Core.Abstractions DriverArrayWriteSupport, says which (driver, element type)
pairs encode a whole-array write: Modbus (Coils / numeric HoldingRegisters),
S7 (Byte/Int16/UInt16/Int32/UInt32/Float32), OpcUaClient (pass-through) and
Galaxy (Boolean/Int32/Int64/Float/Double/String/DateTime). Everything else
stays read-only, so the server never advertises a write the driver refuses.
- Composer derives RawTagPlan.ArrayWritable + UnsReferenceVariable
.BackingArrayWritable at compose time (both seams, byte-parity); the
applier's one writability rule is Writable && (!IsArray || ArrayWritable)
for materialise and surgical paths, raw and UNS alike.
- ArrayWritable is on the classifier's surgical raw-tag whitelist and
mirrored on the UNS record (UnsReferenceBackingParityTests updated).
- Node manager refuses a wrong-length / non-array value on an array node
(BadTypeMismatch) and any IndexRange write (BadWriteNotSupported) inline,
before dispatch; WriteOperate/ACL gates and the revert are unchanged.
- Per-driver parity tests pin the table against the real Modbus write path,
S7 EncodeArrayBlock and Galaxy MxValueEncoder (UInt32/UInt64 excluded:
array covariance reinterprets their bits).
- Over-the-wire proof in OpcUaServer.IntegrationTests (ArrayWriteWireTests).
- ValueRank > 1 documented as out of scope by decision (docs/Uns.md).
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
- Galaxy: deadline bounds the wait, not the subscribe RPC; BadTimeout for all tags and late handles unsubscribed; doc comment relocated
- S7: probe connect runs on the connect deadline so a timeout opens the backoff window
- S7: a successful write only retires a Faulted the write side owns
- S7: null array elements rejected (BadTypeMismatch); multi-PDU array writes documented non-atomic
- S7 integration: array write test gated on S7_SIM_ALLOW_WRITES=1
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
Reverses the conservative call from the previous commit at the user's direction,
and they were right: "surface it on a counter first" left the wire lying. An
MXAccess event can carry Good quality while its payload is a kind MxValueDecoder
has no mapping for, so the old behaviour published null-under-Good — which a
client cannot tell apart from a genuine null reading. A value the gateway DID
send would be consumed as a value it did not, with the only evidence in a log
nobody is tailing. Bad data is the honest wire representation of lost data.
BadTypeMismatch is an existing StatusCodeMap constant, deliberately reused rather
than written inline: StatusCodeParityTests finds status constants by reflecting
over Good/Uncertain/Bad-prefixed uint fields and checking them against the pinned
SDK, so an inline literal would be invisible to that guard (Gitea #497, where 16
wrong constants had accumulated across 6 drivers exactly this way).
Logging is now once per DISTINCT value kind rather than once per pump. The set is
bounded by the MxValue oneof enum so a broken producer still cannot flood, but a
second unrepresentable kind appearing later gets its own line — warn-once-per-pump
would have silently swallowed it, which is the same class of bug as the null this
commit fixes.
The test's fixture matters more than its assertion: the undecodable event carries
Quality = 192 (OPC DA Good), so a decoder that gave up silently would publish Good
and fail. Paired with a positive control — a decodable value at the same quality
must still publish Good — so it cannot be satisfied by a pump that marks
everything Bad. Falsified by reverting the status to Good: the test reds, and only
that test.
Verified: 331 Galaxy tests green, Core.Abstractions 298 (the parity guard),
solution builds 0 errors. Docs corrected in the two places that recorded the old
decision as deliberate.