dohertj2 created pull request dohertj2/lmxopcua#162 2026-04-20 12:11:35 -04:00
Dockerize Modbus + AB CIP + S7 test fixtures for reproducibility
dohertj2 deleted branch opcuaclient-opc-plc-fixture from dohertj2/lmxopcua 2026-04-20 11:45:35 -04:00
dohertj2 pushed to v2 at dohertj2/lmxopcua 2026-04-20 11:45:27 -04:00
3b3e814855 Merge pull request 'OpcUaClient integration fixture � opc-plc in Docker (#215)' (#161) from opcuaclient-opc-plc-fixture into v2
c985c50a96 OpcUaClient integration fixture — opc-plc in Docker closes the wire-level gap (#215). Closes task #215. The OpcUaClient driver had the richest capability matrix in the fleet (reads/writes/subscribe/alarms/history across 11 unit-test classes) + zero wire-level coverage; every test mocked the Session surface. opc-plc is Microsoft Industrial IoT's OPC UA PLC simulator — already containerized, already on MCR, pinned to 2.14.10 here. Wins vs the loopback-against-our-own-server option we'd originally scoped: (a) independent cert chain + user-token handling catches interop bugs loopback can't because both endpoints would share our own cert store; (b) pinned image tag fixes the test surface in a way our evolving server wouldn't; (c) the --alm flag opens the door to real IAlarmSource coverage later without building a custom FakeAlarmDriver. Loss vs loopback: both use the OPCFoundation.NetStandard stack internally so bugs common to that stack don't surface — addressed by a follow-up to add open62541/open62541 as a second independent-stack image (tracked). Docker is the fixture launcher — no PowerShell/Python wrapper like Modbus/pymodbus or S7/python-snap7 because opc-plc ships containerized. Docker/docker-compose.yml pins 2.14.10 + maps port 50000 + command flags --pn=50000 --ut --aa --alm; the healthcheck TCP-probes 50000 so docker ps surfaces ready state. Fixture OpcPlcFixture follows the same shape as Snap7ServerFixture + ModbusSimulatorFixture: collection-scoped, parses OPCUA_SIM_ENDPOINT (default opc.tcp://localhost:50000) into host + port, 2-second TCP probe at init, SkipReason records the failure for Assert.Skip. Forced IPv4 on the probe socket for the same reason those two fixtures do — .NET's dual-stack "localhost" resolves IPv6 ::1 first + hangs the full connect timeout when the target binds 0.0.0.0 (IPv4). OpcPlcProfile holds well-known node identifiers opc-plc exposes (ns=3;s=StepUp, FastUInt1, RandomSignedInt32, AlternatingBoolean) + builds OpcUaClientDriverOptions with SecurityPolicy.None + AutoAcceptCertificates=true since opc-plc regenerates its server cert on every container spin-up + there's no meaningful chain to validate against in CI. Three smoke tests covering what the unit suite couldn't reach: (1) Client_connects_and_reads_StepUp_node_through_real_OPC_UA_stack — full Secure Channel + Session + Read on ns=3;s=StepUp (counter that ticks every 1 s); (2) Client_reads_batch_of_varied_types_from_live_simulator — batch Read of UInt32 / Int32 / Boolean to prove typed Variant decoding, with an explicit ShouldBeOfType<bool> assertion on AlternatingBoolean to catch the common "variant gets stringified" regression; (3) Client_subscribe_receives_StepUp_data_changes_from_live_server — real MonitoredItem subscription on FastUInt1 (100 ms cadence) with a SemaphoreSlim gate + 3 s deadline on the first OnDataChange fire, tolerating container warm-up. Driver ran end-to-end against a live 2.14.10 container: all 3 pass; unit suite 78/78 unchanged. Container lifecycle verified (compose up → tests → compose down) clean, no leaked state. Docker/README.md documents install (Docker Desktop already on the dev box per Phase 1 decision #134), run (compose up / compose up -d / compose down), endpoint override (OPCUA_SIM_ENDPOINT), what opc-plc advertises with the current command flags, what's tunable via compose-file tweaks (--daa for username auth tests; --fn/--fr/--ft for subscription-stress nodes), known limitation that opc-plc shares the OPCFoundation stack with our driver. OpcUaClient-Test-Fixture.md updated — TL;DR flipped from "there is no integration fixture" to the new reality; "What it actually covers" gains an Integration section listing the three smoke tests. Follow-up the doc flags: add open62541/open62541 as a second image for fully-independent-stack interop coverage; once #219 (server-side IAlarmSource/IHistoryProvider integration tests) lands, re-run the client-side suite against opc-plc's --alm nodes to close the alarm gap from the client side too.
Compare 2 commits »
dohertj2 merged pull request dohertj2/lmxopcua#161 2026-04-20 11:45:26 -04:00
OpcUaClient integration fixture � opc-plc in Docker (#215)
dohertj2 created branch opcuaclient-opc-plc-fixture in dohertj2/lmxopcua 2026-04-20 11:45:10 -04:00
dohertj2 pushed to opcuaclient-opc-plc-fixture at dohertj2/lmxopcua 2026-04-20 11:45:10 -04:00
c985c50a96 OpcUaClient integration fixture — opc-plc in Docker closes the wire-level gap (#215). Closes task #215. The OpcUaClient driver had the richest capability matrix in the fleet (reads/writes/subscribe/alarms/history across 11 unit-test classes) + zero wire-level coverage; every test mocked the Session surface. opc-plc is Microsoft Industrial IoT's OPC UA PLC simulator — already containerized, already on MCR, pinned to 2.14.10 here. Wins vs the loopback-against-our-own-server option we'd originally scoped: (a) independent cert chain + user-token handling catches interop bugs loopback can't because both endpoints would share our own cert store; (b) pinned image tag fixes the test surface in a way our evolving server wouldn't; (c) the --alm flag opens the door to real IAlarmSource coverage later without building a custom FakeAlarmDriver. Loss vs loopback: both use the OPCFoundation.NetStandard stack internally so bugs common to that stack don't surface — addressed by a follow-up to add open62541/open62541 as a second independent-stack image (tracked). Docker is the fixture launcher — no PowerShell/Python wrapper like Modbus/pymodbus or S7/python-snap7 because opc-plc ships containerized. Docker/docker-compose.yml pins 2.14.10 + maps port 50000 + command flags --pn=50000 --ut --aa --alm; the healthcheck TCP-probes 50000 so docker ps surfaces ready state. Fixture OpcPlcFixture follows the same shape as Snap7ServerFixture + ModbusSimulatorFixture: collection-scoped, parses OPCUA_SIM_ENDPOINT (default opc.tcp://localhost:50000) into host + port, 2-second TCP probe at init, SkipReason records the failure for Assert.Skip. Forced IPv4 on the probe socket for the same reason those two fixtures do — .NET's dual-stack "localhost" resolves IPv6 ::1 first + hangs the full connect timeout when the target binds 0.0.0.0 (IPv4). OpcPlcProfile holds well-known node identifiers opc-plc exposes (ns=3;s=StepUp, FastUInt1, RandomSignedInt32, AlternatingBoolean) + builds OpcUaClientDriverOptions with SecurityPolicy.None + AutoAcceptCertificates=true since opc-plc regenerates its server cert on every container spin-up + there's no meaningful chain to validate against in CI. Three smoke tests covering what the unit suite couldn't reach: (1) Client_connects_and_reads_StepUp_node_through_real_OPC_UA_stack — full Secure Channel + Session + Read on ns=3;s=StepUp (counter that ticks every 1 s); (2) Client_reads_batch_of_varied_types_from_live_simulator — batch Read of UInt32 / Int32 / Boolean to prove typed Variant decoding, with an explicit ShouldBeOfType<bool> assertion on AlternatingBoolean to catch the common "variant gets stringified" regression; (3) Client_subscribe_receives_StepUp_data_changes_from_live_server — real MonitoredItem subscription on FastUInt1 (100 ms cadence) with a SemaphoreSlim gate + 3 s deadline on the first OnDataChange fire, tolerating container warm-up. Driver ran end-to-end against a live 2.14.10 container: all 3 pass; unit suite 78/78 unchanged. Container lifecycle verified (compose up → tests → compose down) clean, no leaked state. Docker/README.md documents install (Docker Desktop already on the dev box per Phase 1 decision #134), run (compose up / compose up -d / compose down), endpoint override (OPCUA_SIM_ENDPOINT), what opc-plc advertises with the current command flags, what's tunable via compose-file tweaks (--daa for username auth tests; --fn/--fr/--ft for subscription-stress nodes), known limitation that opc-plc shares the OPCFoundation stack with our driver. OpcUaClient-Test-Fixture.md updated — TL;DR flipped from "there is no integration fixture" to the new reality; "What it actually covers" gains an Integration section listing the three smoke tests. Follow-up the doc flags: add open62541/open62541 as a second image for fully-independent-stack interop coverage; once #219 (server-side IAlarmSource/IHistoryProvider integration tests) lands, re-run the client-side suite against opc-plc's --alm nodes to close the alarm gap from the client side too.
dohertj2 created pull request dohertj2/lmxopcua#161 2026-04-20 11:45:10 -04:00
OpcUaClient integration fixture � opc-plc in Docker (#215)
dohertj2 deleted branch s7-integration-fixture from dohertj2/lmxopcua 2026-04-20 11:31:23 -04:00
dohertj2 pushed to v2 at dohertj2/lmxopcua 2026-04-20 11:31:18 -04:00
820567bc2a Merge pull request 'S7 integration fixture via python-snap7 (#216) + per-driver test-fixture coverage docs' (#160) from s7-integration-fixture into v2
1d3544f18e S7 integration fixture — python-snap7 server closes the wire-level coverage gap (#216) + per-driver fixture coverage docs for every driver in the fleet. Closes #216. Two shipments in one PR because the docs landed as I surveyed each driver's fixture + the S7 work is the first wire-level-gap closer pulled from that survey.
Compare 2 commits »
dohertj2 merged pull request dohertj2/lmxopcua#160 2026-04-20 11:31:16 -04:00
S7 integration fixture via python-snap7 (#216) + per-driver test-fixture coverage docs
dohertj2 created pull request dohertj2/lmxopcua#160 2026-04-20 11:31:06 -04:00
S7 integration fixture via python-snap7 (#216) + per-driver test-fixture coverage docs
dohertj2 created branch s7-integration-fixture in dohertj2/lmxopcua 2026-04-20 11:31:06 -04:00
dohertj2 pushed to s7-integration-fixture at dohertj2/lmxopcua 2026-04-20 11:31:06 -04:00
1d3544f18e S7 integration fixture — python-snap7 server closes the wire-level coverage gap (#216) + per-driver fixture coverage docs for every driver in the fleet. Closes #216. Two shipments in one PR because the docs landed as I surveyed each driver's fixture + the S7 work is the first wire-level-gap closer pulled from that survey.
dohertj2 deleted branch abcip-alarm-source from dohertj2/lmxopcua 2026-04-20 04:26:46 -04:00
dohertj2 merged pull request dohertj2/lmxopcua#159 2026-04-20 04:26:41 -04:00
AbCip IAlarmSource via ALMD projection (#177, feature-flagged)
dohertj2 pushed to v2 at dohertj2/lmxopcua 2026-04-20 04:26:41 -04:00
4fe96fca9b Merge pull request 'AbCip IAlarmSource via ALMD projection (#177, feature-flagged)' (#159) from abcip-alarm-source into v2
4e80db4844 AbCip IAlarmSource via ALMD projection (#177) — feature-flagged OFF by default; when enabled, polls declared ALMD UDT member fields + raises OnAlarmEvent on 0→1 + 1→0 transitions. Closes task #177. The AB CIP driver now implements IAlarmSource so the generic-driver alarm dispatch path (PR 14's sinks + the Server.Security.AuthorizationGate AlarmSubscribe/AlarmAck invoker wrapping) can treat AB-backed alarms uniformly with Galaxy + OpcUaClient + FOCAS. Projection is ALMD-only in this pass: the Logix ALMD (digital alarm) instruction's UDT shape is well-understood (InFaulted + Acked + Severity + In + Cfg_ProgTime at stable member names) so the polled-read + state-diff pattern fits without concessions. ALMA (analog alarm) deferred to a follow-up because its HHLimit/HLimit/LLimit/LLLimit threshold + In value semantics deserve their own design pass — raising on threshold-crossing is not the same shape as raising on InFaulted-edge. AbCipDriverOptions gains two knobs: EnableAlarmProjection (default false) + AlarmPollInterval (default 1s). Explicit opt-in because projection semantics don't exactly mirror Rockwell FT Alarm & Events; shops running FT Live should leave this off + take alarms through the native A&E route. AbCipAlarmProjection is the state machine: per-subscription background loop polls the source-node set via the driver's public ReadAsync — which gains the #194 whole-UDT optimization for free when ALMDs are declared with their standard member set, so one poll tick reads (N alarms × 2 members) = N libplctag round-trips rather than 2N. Per-tick state diff: compare InFaulted + Severity against last-seen, fire raise (0→1) / clear (1→0) with AlarmSeverity bucketed via the 1-1000 Logix severity scale (≤250 Low, ≤500 Medium, ≤750 High, rest Critical — matches OpcUaClient's MapSeverity shape). ConditionId is {sourceNode}#active — matches a single active-branch per alarm which is all ALMD supports; when Cfg_ProgTime-based branch identity becomes interesting (re-raise after ack with new timestamp), a richer ConditionId pass can land. Subscribe-while-disabled returns a handle wrapping id=0 — capability negotiation (the server queries IAlarmSource presence at driver-load time) still succeeds, the alarm surface just never fires. Unsubscribe cancels the sub's CTS + awaits its loop; ShutdownAsync cancels every sub on its way out so a driver reload doesn't leak poll tasks. AcknowledgeAsync routes through the driver's existing WriteAsync path — per-ack writes {SourceNodeId}.Acked = true (the simpler semantic; operators whose ladder watches AckCmd + rising-edge can wire a client-side pulse until a driver-level edge-mode knob lands). Best-effort — per-ack faults are swallowed so one bad ack doesn't poison the whole batch. Six new AbCipAlarmProjectionTests: detector flags ALMD signature + skips non-signature UDTs + atomics; severity mapping matches OPC UA A&C bucket boundaries; feature-flag OFF returns a handle but never touches the fake runtime (proving no background polling happens); feature-flag ON fires a raise event on 0→1; clear event fires on 1→0 after a prior raise; unsubscribe stops the poll loop (ReadCount doesn't grow past cancel + at most one straggler read). Driver builds 0 errors; AbCip.Tests 233/233 (was 227, +6 new). Task #177 closed — the last pending AB CIP follow-up is now #194 (already shipped). Remaining pending fleet-wide: #150 (Galaxy MXAccess failover hardware) + #199 (UnsTab Playwright smoke).
Compare 2 commits »
dohertj2 created pull request dohertj2/lmxopcua#159 2026-04-20 04:26:28 -04:00
AbCip IAlarmSource via ALMD projection (#177, feature-flagged)
dohertj2 created branch abcip-alarm-source in dohertj2/lmxopcua 2026-04-20 04:26:26 -04:00
dohertj2 pushed to abcip-alarm-source at dohertj2/lmxopcua 2026-04-20 04:26:26 -04:00
4e80db4844 AbCip IAlarmSource via ALMD projection (#177) — feature-flagged OFF by default; when enabled, polls declared ALMD UDT member fields + raises OnAlarmEvent on 0→1 + 1→0 transitions. Closes task #177. The AB CIP driver now implements IAlarmSource so the generic-driver alarm dispatch path (PR 14's sinks + the Server.Security.AuthorizationGate AlarmSubscribe/AlarmAck invoker wrapping) can treat AB-backed alarms uniformly with Galaxy + OpcUaClient + FOCAS. Projection is ALMD-only in this pass: the Logix ALMD (digital alarm) instruction's UDT shape is well-understood (InFaulted + Acked + Severity + In + Cfg_ProgTime at stable member names) so the polled-read + state-diff pattern fits without concessions. ALMA (analog alarm) deferred to a follow-up because its HHLimit/HLimit/LLimit/LLLimit threshold + In value semantics deserve their own design pass — raising on threshold-crossing is not the same shape as raising on InFaulted-edge. AbCipDriverOptions gains two knobs: EnableAlarmProjection (default false) + AlarmPollInterval (default 1s). Explicit opt-in because projection semantics don't exactly mirror Rockwell FT Alarm & Events; shops running FT Live should leave this off + take alarms through the native A&E route. AbCipAlarmProjection is the state machine: per-subscription background loop polls the source-node set via the driver's public ReadAsync — which gains the #194 whole-UDT optimization for free when ALMDs are declared with their standard member set, so one poll tick reads (N alarms × 2 members) = N libplctag round-trips rather than 2N. Per-tick state diff: compare InFaulted + Severity against last-seen, fire raise (0→1) / clear (1→0) with AlarmSeverity bucketed via the 1-1000 Logix severity scale (≤250 Low, ≤500 Medium, ≤750 High, rest Critical — matches OpcUaClient's MapSeverity shape). ConditionId is {sourceNode}#active — matches a single active-branch per alarm which is all ALMD supports; when Cfg_ProgTime-based branch identity becomes interesting (re-raise after ack with new timestamp), a richer ConditionId pass can land. Subscribe-while-disabled returns a handle wrapping id=0 — capability negotiation (the server queries IAlarmSource presence at driver-load time) still succeeds, the alarm surface just never fires. Unsubscribe cancels the sub's CTS + awaits its loop; ShutdownAsync cancels every sub on its way out so a driver reload doesn't leak poll tasks. AcknowledgeAsync routes through the driver's existing WriteAsync path — per-ack writes {SourceNodeId}.Acked = true (the simpler semantic; operators whose ladder watches AckCmd + rising-edge can wire a client-side pulse until a driver-level edge-mode knob lands). Best-effort — per-ack faults are swallowed so one bad ack doesn't poison the whole batch. Six new AbCipAlarmProjectionTests: detector flags ALMD signature + skips non-signature UDTs + atomics; severity mapping matches OPC UA A&C bucket boundaries; feature-flag OFF returns a handle but never touches the fake runtime (proving no background polling happens); feature-flag ON fires a raise event on 0→1; clear event fires on 1→0 after a prior raise; unsubscribe stops the poll loop (ReadCount doesn't grow past cancel + at most one straggler read). Driver builds 0 errors; AbCip.Tests 233/233 (was 227, +6 new). Task #177 closed — the last pending AB CIP follow-up is now #194 (already shipped). Remaining pending fleet-wide: #150 (Galaxy MXAccess failover hardware) + #199 (UnsTab Playwright smoke).