AbCip IAlarmSource via ALMD projection (#177, feature-flagged) #159

Merged
dohertj2 merged 1 commits from abcip-alarm-source into v2 2026-04-20 04:26:40 -04:00
Owner

Closes #177. AbCipDriver now implements IAlarmSource via ALMD tag-projection (InFaulted/Acked/Severity polling ? OnAlarmEvent raise/clear). Feature-flagged off by default (EnableAlarmProjection=false). ALMA deferred. Polling reuses ReadAsync, so it inherits the #194 whole-UDT optimization. AbCip.Tests 233/233 (was 227, +6).

Closes #177. AbCipDriver now implements IAlarmSource via ALMD tag-projection (InFaulted/Acked/Severity polling ? OnAlarmEvent raise/clear). Feature-flagged off by default (EnableAlarmProjection=false). ALMA deferred. Polling reuses ReadAsync, so it inherits the #194 whole-UDT optimization. AbCip.Tests 233/233 (was 227, +6).
dohertj2 added 1 commit 2026-04-20 04:26:28 -04:00
AbCip IAlarmSource via ALMD projection (#177) — feature-flagged OFF by default; when enabled, polls declared ALMD UDT member fields + raises OnAlarmEvent on 0→1 + 1→0 transitions. Closes task #177. The AB CIP driver now implements IAlarmSource so the generic-driver alarm dispatch path (PR 14's sinks + the Server.Security.AuthorizationGate AlarmSubscribe/AlarmAck invoker wrapping) can treat AB-backed alarms uniformly with Galaxy + OpcUaClient + FOCAS. Projection is ALMD-only in this pass: the Logix ALMD (digital alarm) instruction's UDT shape is well-understood (InFaulted + Acked + Severity + In + Cfg_ProgTime at stable member names) so the polled-read + state-diff pattern fits without concessions. ALMA (analog alarm) deferred to a follow-up because its HHLimit/HLimit/LLimit/LLLimit threshold + In value semantics deserve their own design pass — raising on threshold-crossing is not the same shape as raising on InFaulted-edge. AbCipDriverOptions gains two knobs: EnableAlarmProjection (default false) + AlarmPollInterval (default 1s). Explicit opt-in because projection semantics don't exactly mirror Rockwell FT Alarm & Events; shops running FT Live should leave this off + take alarms through the native A&E route. AbCipAlarmProjection is the state machine: per-subscription background loop polls the source-node set via the driver's public ReadAsync — which gains the #194 whole-UDT optimization for free when ALMDs are declared with their standard member set, so one poll tick reads (N alarms × 2 members) = N libplctag round-trips rather than 2N. Per-tick state diff: compare InFaulted + Severity against last-seen, fire raise (0→1) / clear (1→0) with AlarmSeverity bucketed via the 1-1000 Logix severity scale (≤250 Low, ≤500 Medium, ≤750 High, rest Critical — matches OpcUaClient's MapSeverity shape). ConditionId is {sourceNode}#active — matches a single active-branch per alarm which is all ALMD supports; when Cfg_ProgTime-based branch identity becomes interesting (re-raise after ack with new timestamp), a richer ConditionId pass can land. Subscribe-while-disabled returns a handle wrapping id=0 — capability negotiation (the server queries IAlarmSource presence at driver-load time) still succeeds, the alarm surface just never fires. Unsubscribe cancels the sub's CTS + awaits its loop; ShutdownAsync cancels every sub on its way out so a driver reload doesn't leak poll tasks. AcknowledgeAsync routes through the driver's existing WriteAsync path — per-ack writes {SourceNodeId}.Acked = true (the simpler semantic; operators whose ladder watches AckCmd + rising-edge can wire a client-side pulse until a driver-level edge-mode knob lands). Best-effort — per-ack faults are swallowed so one bad ack doesn't poison the whole batch. Six new AbCipAlarmProjectionTests: detector flags ALMD signature + skips non-signature UDTs + atomics; severity mapping matches OPC UA A&C bucket boundaries; feature-flag OFF returns a handle but never touches the fake runtime (proving no background polling happens); feature-flag ON fires a raise event on 0→1; clear event fires on 1→0 after a prior raise; unsubscribe stops the poll loop (ReadCount doesn't grow past cancel + at most one straggler read). Driver builds 0 errors; AbCip.Tests 233/233 (was 227, +6 new). Task #177 closed — the last pending AB CIP follow-up is now #194 (already shipped). Remaining pending fleet-wide: #150 (Galaxy MXAccess failover hardware) + #199 (UnsTab Playwright smoke). 4e80db4844
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
dohertj2 merged commit 4fe96fca9b into v2 2026-04-20 04:26:40 -04:00
dohertj2 referenced this issue from a commit 2026-04-30 08:21:26 -04:00
Admin Equipment editor — IdentificationFields component + edit mode + three missing OPC 40010 fields. Closes the UI-editor slice of task #159 (Phase 6.4 Stream D remaining); the DriverNodeManager wire-in + ACL integration test are split into a new follow-up task #195 because they're blocked on a prerequisite that hasn't shipped — the DriverNodeManager does not currently materialize Equipment nodes at all (NodeScopeResolver has an explicit "A future resolver will..." TODO in its decomposition docstring). Shipping the IdentificationFolderBuilder call before the parent walker exists would wire a call that no code path hits, so the wire-in is deferred until the Equipment node walker lands first. New IdentificationFields.razor reusable component renders the 9-field decision #139 grid in a Bootstrap 3-column layout — Manufacturer, Model, SerialNumber, HardwareRevision, SoftwareRevision, YearOfConstruction (InputNumber), AssetLocation, ManufacturerUri (placeholder https://…), DeviceManualUri (placeholder https://…). Takes a required Equipment parameter + 2-way binds every field; no state of its own. Three fields that were missing from the old inline form — AssetLocation, ManufacturerUri, DeviceManualUri — now present, matching IdentificationFolderBuilder.FieldNames exactly. EquipmentTab.razor refactored to consume the component in both create + edit flows. Each table row gains an Edit button next to Remove. StartEdit clones the row into _draft so Cancel doesn't mutate the displayed list row with in-flight edits; on Save, UpdateAsync persists through EquipmentService's existing update path which already handles all 9 Identification fields. SaveAsync branches on _editMode — create still derives EquipmentId from a fresh Uuid via DraftValidator per decision #125, edit keeps the original EquipmentId + EquipmentUuid (immutable once set). FormName renamed equipment-form (was new-equipment) to work for both flows. Admin project builds 0 errors; Admin.Tests 72/72 passing. No new tests shipped — this PR is strictly a Razor-component refactor + two new bound fields + an Edit branch; the existing EquipmentService tests cover both the create + update paths. Task #195 created to track the blocked server-side work: call IdentificationFolderBuilder.Build from DriverNodeManager once the Equipment walker exists, plus an integration test browsing Equipment/Identification as an unauthorized user asserting BadUserAccessDenied per the builder's cross-reference note in docs/v2/acl-design.md §Identification.