dohertj2 dohertj2
  • Joined on 2026-02-20
dohertj2 pushed to v2 at dohertj2/lmxopcua 2026-04-20 04:19:54 -04:00
f6d5763448 Merge pull request 'AbCip whole-UDT read optimization (#194)' (#158) from abcip-whole-udt-read into v2
780358c790 AbCip whole-UDT read optimization (#194) — declaration-driven member grouping collapses N per-member reads into one parent-UDT read + client-side decode. Closes task #194. On a batch that includes multiple members of the same hand-declared UDT tag, ReadAsync now issues one libplctag read on the parent + decodes each member from the runtime's buffer at its computed byte offset. A 6-member Motor UDT read goes from 6 libplctag round-trips to 1 — the Rockwell-suggested pattern for minimizing CIP request overhead on batch reads of UDT state (decision #11's follow-through on what the template decoder from task #179 was meant to enable). AbCipUdtMemberLayout is a pure-function helper that computes declared-member byte offsets under Logix natural-alignment rules (SInt 1-byte / Int 2-byte / DInt + Real + Dt 4-byte / LInt + ULInt + LReal 8-byte; alignment pad inserted before each member as needed). Opts out for BOOL / String / Structure members — BOOL storage in Logix UDTs packs into a hidden host byte whose position can't be computed from declaration-only info, and String members need length-prefix + STRING[82] fan-out which libplctag already handles via a per-tag DecodeValue path. The CIP Template Object shape from task #179 (when populated via FetchUdtShapeAsync) carries real offsets for those members — layering that richer path on top of the planner is a separate follow-up and does not change this PR's conservative behaviour. AbCipUdtReadPlanner is the scheduling function ReadAsync consults each batch — pure over (requests, tagsByName), emits Groups + Fallbacks. A group is formed when (a) the reference resolves to "parent.member"; (b) parent is a Structure tag with declared Members; (c) the layout helper succeeds on those members; (d) the specific member appears in the computed offset map; (e) at least two members of the same parent appear in the batch — single-member groups demote to the fallback path because one whole-UDT read vs one per-member read is equivalent cost but more client-side work. Original batch indices are preserved through the plan so out-of-order batches write decoded values back at the right output slot; the caller's result array order is invariant. IAbCipTagRuntime.DecodeValueAt(AbCipDataType, int offset, int? bitIndex) is the new hot-path method — LibplctagTagRuntime delegates to libplctag's offset-aware Get*(offset) calls (GetInt32, GetFloat32, etc.) that were always there; previously every call passed offset 0. DecodeValue(type, bitIndex) stays as the shorthand + forwards to DecodeValueAt with offset 0, preserving the existing single-tag read path + every test that exercises it. FakeAbCipTag gains a ValuesByOffset dictionary so tests can drive multi-member decoding by setting offset→value before the read fires; unmapped offsets fall back to the existing Value field so the 200+ existing tests that never set ValuesByOffset keep working unchanged. AbCipDriver.ReadAsync refactored: planner splits the batch, ReadGroupAsync handles each UDT group (one EnsureTagRuntimeAsync on the parent + one ReadAsync + N DecodeValueAt calls), ReadSingleAsync handles each fallback (the pre-#194 per-tag path, now extracted + threaded through). A per-group failure stamps the mapped libplctag status across every grouped member only — sibling groups + fallback refs are unaffected. Health-surface updates happen once per successful group rather than once per member to avoid ping-ponging the DriverState bookkeeping. Five AbCipUdtMemberLayoutTests: packed atomics get natural-alignment offsets including 8-byte pad before LInt; SInts pack without padding; BOOL/String/Structure opt out + return null; empty member list returns null. Six AbCipUdtReadPlannerTests: two members group; single-member demotes to fallback; unknown references fall back without poisoning groups; atomic top-level tags fall back untouched; UDTs containing BOOL don't group; original indices survive out-of-order batches. Five AbCipDriverWholeUdtReadTests (real driver + fake runtime): two grouped members trigger exactly one parent read + one fake runtime (proving the optimization engages); each member decodes at its own offset via ValuesByOffset; parent-read non-zero status stamps Bad across the group; mixed UDT-member + atomic top-level batch produces 2 runtimes + 2 reads (not 3); single-member-of-UDT still uses the member-level runtime (proving demotion works). Driver builds 0 errors; AbCip.Tests 227/227 (was 211, +16 new).
Compare 2 commits »
dohertj2 merged pull request dohertj2/lmxopcua#158 2026-04-20 04:19:53 -04:00
AbCip whole-UDT read optimization (#194)
dohertj2 created pull request dohertj2/lmxopcua#158 2026-04-20 04:19:44 -04:00
AbCip whole-UDT read optimization (#194)
dohertj2 created branch abcip-whole-udt-read in dohertj2/lmxopcua 2026-04-20 04:19:44 -04:00
dohertj2 pushed to abcip-whole-udt-read at dohertj2/lmxopcua 2026-04-20 04:19:44 -04:00
780358c790 AbCip whole-UDT read optimization (#194) — declaration-driven member grouping collapses N per-member reads into one parent-UDT read + client-side decode. Closes task #194. On a batch that includes multiple members of the same hand-declared UDT tag, ReadAsync now issues one libplctag read on the parent + decodes each member from the runtime's buffer at its computed byte offset. A 6-member Motor UDT read goes from 6 libplctag round-trips to 1 — the Rockwell-suggested pattern for minimizing CIP request overhead on batch reads of UDT state (decision #11's follow-through on what the template decoder from task #179 was meant to enable). AbCipUdtMemberLayout is a pure-function helper that computes declared-member byte offsets under Logix natural-alignment rules (SInt 1-byte / Int 2-byte / DInt + Real + Dt 4-byte / LInt + ULInt + LReal 8-byte; alignment pad inserted before each member as needed). Opts out for BOOL / String / Structure members — BOOL storage in Logix UDTs packs into a hidden host byte whose position can't be computed from declaration-only info, and String members need length-prefix + STRING[82] fan-out which libplctag already handles via a per-tag DecodeValue path. The CIP Template Object shape from task #179 (when populated via FetchUdtShapeAsync) carries real offsets for those members — layering that richer path on top of the planner is a separate follow-up and does not change this PR's conservative behaviour. AbCipUdtReadPlanner is the scheduling function ReadAsync consults each batch — pure over (requests, tagsByName), emits Groups + Fallbacks. A group is formed when (a) the reference resolves to "parent.member"; (b) parent is a Structure tag with declared Members; (c) the layout helper succeeds on those members; (d) the specific member appears in the computed offset map; (e) at least two members of the same parent appear in the batch — single-member groups demote to the fallback path because one whole-UDT read vs one per-member read is equivalent cost but more client-side work. Original batch indices are preserved through the plan so out-of-order batches write decoded values back at the right output slot; the caller's result array order is invariant. IAbCipTagRuntime.DecodeValueAt(AbCipDataType, int offset, int? bitIndex) is the new hot-path method — LibplctagTagRuntime delegates to libplctag's offset-aware Get*(offset) calls (GetInt32, GetFloat32, etc.) that were always there; previously every call passed offset 0. DecodeValue(type, bitIndex) stays as the shorthand + forwards to DecodeValueAt with offset 0, preserving the existing single-tag read path + every test that exercises it. FakeAbCipTag gains a ValuesByOffset dictionary so tests can drive multi-member decoding by setting offset→value before the read fires; unmapped offsets fall back to the existing Value field so the 200+ existing tests that never set ValuesByOffset keep working unchanged. AbCipDriver.ReadAsync refactored: planner splits the batch, ReadGroupAsync handles each UDT group (one EnsureTagRuntimeAsync on the parent + one ReadAsync + N DecodeValueAt calls), ReadSingleAsync handles each fallback (the pre-#194 per-tag path, now extracted + threaded through). A per-group failure stamps the mapped libplctag status across every grouped member only — sibling groups + fallback refs are unaffected. Health-surface updates happen once per successful group rather than once per member to avoid ping-ponging the DriverState bookkeeping. Five AbCipUdtMemberLayoutTests: packed atomics get natural-alignment offsets including 8-byte pad before LInt; SInts pack without padding; BOOL/String/Structure opt out + return null; empty member list returns null. Six AbCipUdtReadPlannerTests: two members group; single-member demotes to fallback; unknown references fall back without poisoning groups; atomic top-level tags fall back untouched; UDTs containing BOOL don't group; original indices survive out-of-order batches. Five AbCipDriverWholeUdtReadTests (real driver + fake runtime): two grouped members trigger exactly one parent read + one fake runtime (proving the optimization engages); each member decodes at its own offset via ValuesByOffset; parent-read non-zero status stamps Bad across the group; mixed UDT-member + atomic top-level batch produces 2 runtimes + 2 reads (not 3); single-member-of-UDT still uses the member-level runtime (proving demotion works). Driver builds 0 errors; AbCip.Tests 227/227 (was 211, +16 new).
dohertj2 deleted branch equipment-content-wiring from dohertj2/lmxopcua 2026-04-20 03:52:39 -04:00
dohertj2 pushed to v2 at dohertj2/lmxopcua 2026-04-20 03:52:34 -04:00
1ac87f1fac Merge pull request 'ADR-001 last-mile � Program.cs composes walker into production boot (#214)' (#157) from equipment-content-wiring into v2
432173c5c4 ADR-001 last-mile — Program.cs composes EquipmentNodeWalker into the production boot path. Closes task #214 + fully lands ADR-001 Option A as a live code path, not just a connected set of unit-tested primitives. After this PR a server booted against a real Config DB with Published Equipment rows materializes the UNS tree into the OPC UA address space on startup — the whole walker → wire-in → loader chain (PRs #153, #154, #155, #156) finally fires end-to-end in the production process. DriverEquipmentContentRegistry is the handoff between OpcUaServerService's bootstrap-time populate pass + OpcUaApplicationHost's StartAsync walker invocation. It's a singleton mutable holder with Get/Set/Count + Lock-guarded internal dictionary keyed OrdinalIgnoreCase to match the DriverInstanceId convention used by Equipment / Tag rows + walker grouping. Set-once-per-bootstrap semantics in practice though nothing enforces that at the type level — OpcUaServerService.PopulateEquipmentContentAsync is the only expected writer. Shared-mutable rather than immutable-passed-by-value because the DI graph builds OpcUaApplicationHost before NodeBootstrap has resolved the generation, so the registry must exist at compose time + fill at boot time. Program.cs now registers OpcUaApplicationHost via a factory lambda that threads registry.Get as the equipmentContentLookup delegate PR #155 added to the ctor seam — the one-line composition the earlier PR promised. EquipmentNamespaceContentLoader (from PR #156) is AddScoped since it takes the scoped OtOpcUaConfigDbContext; the populate pass in OpcUaServerService opens one IServiceScopeFactory scope + reuses the same loader + DbContext across every driver query rather than scoping-per-driver. OpcUaServerService.ExecuteAsync gets a new PopulateEquipmentContentAsync step between bootstrap + StartAsync: iterates DriverHost.RegisteredDriverIds, calls loader.LoadAsync per driver at the bootstrapped generationId, stashes non-null results in the registry. Null results are skipped — the wire-in's null-check treats absent registry entries as "this driver isn't Equipment-kind; let DiscoverAsync own the address space" which is the correct backward-compat path for Modbus / AB CIP / TwinCAT / FOCAS. Guarded on result.GenerationId being non-null — a fleet with no Published generation yet boots cleanly into a UNS-less address space and fills the registry on the next restart after first publish. Ctor on OpcUaServerService gained two new dependencies (DriverEquipmentContentRegistry + IServiceScopeFactory). No test file constructs OpcUaServerService directly so no downstream test breakage — the BackgroundService is only wired via DI in Program.cs. Four new DriverEquipmentContentRegistryTests: Get-null-for-unknown, Set-then-Get, case-insensitive driver-id lookup, Set-overwrites-existing. Server.Tests 190/190 (was 186, +4 new registry tests). Full ADR-001 Option A now lives at every layer: Core.OpcUa walker (#153) → ScopePathIndexBuilder (#154) → OpcUaApplicationHost wire-in (#155) → EquipmentNamespaceContentLoader (#156) → this PR's registry + Program.cs composition. The last pending loose end (full-integration smoke test that boots Program.cs against a seeded Config DB + verifies UNS tree via live OPC UA client) isn't strictly necessary because PR #155's OpcUaEquipmentWalkerIntegrationTests already proves the wire-in at the OPC UA client-browse level — the Program.cs composition added here is purely mechanical + well-covered by the four-file audit trail plus registry unit tests.
Compare 2 commits »
dohertj2 merged pull request dohertj2/lmxopcua#157 2026-04-20 03:52:32 -04:00
ADR-001 last-mile � Program.cs composes walker into production boot (#214)
dohertj2 created branch equipment-content-wiring in dohertj2/lmxopcua 2026-04-20 03:52:24 -04:00
dohertj2 pushed to equipment-content-wiring at dohertj2/lmxopcua 2026-04-20 03:52:24 -04:00
432173c5c4 ADR-001 last-mile — Program.cs composes EquipmentNodeWalker into the production boot path. Closes task #214 + fully lands ADR-001 Option A as a live code path, not just a connected set of unit-tested primitives. After this PR a server booted against a real Config DB with Published Equipment rows materializes the UNS tree into the OPC UA address space on startup — the whole walker → wire-in → loader chain (PRs #153, #154, #155, #156) finally fires end-to-end in the production process. DriverEquipmentContentRegistry is the handoff between OpcUaServerService's bootstrap-time populate pass + OpcUaApplicationHost's StartAsync walker invocation. It's a singleton mutable holder with Get/Set/Count + Lock-guarded internal dictionary keyed OrdinalIgnoreCase to match the DriverInstanceId convention used by Equipment / Tag rows + walker grouping. Set-once-per-bootstrap semantics in practice though nothing enforces that at the type level — OpcUaServerService.PopulateEquipmentContentAsync is the only expected writer. Shared-mutable rather than immutable-passed-by-value because the DI graph builds OpcUaApplicationHost before NodeBootstrap has resolved the generation, so the registry must exist at compose time + fill at boot time. Program.cs now registers OpcUaApplicationHost via a factory lambda that threads registry.Get as the equipmentContentLookup delegate PR #155 added to the ctor seam — the one-line composition the earlier PR promised. EquipmentNamespaceContentLoader (from PR #156) is AddScoped since it takes the scoped OtOpcUaConfigDbContext; the populate pass in OpcUaServerService opens one IServiceScopeFactory scope + reuses the same loader + DbContext across every driver query rather than scoping-per-driver. OpcUaServerService.ExecuteAsync gets a new PopulateEquipmentContentAsync step between bootstrap + StartAsync: iterates DriverHost.RegisteredDriverIds, calls loader.LoadAsync per driver at the bootstrapped generationId, stashes non-null results in the registry. Null results are skipped — the wire-in's null-check treats absent registry entries as "this driver isn't Equipment-kind; let DiscoverAsync own the address space" which is the correct backward-compat path for Modbus / AB CIP / TwinCAT / FOCAS. Guarded on result.GenerationId being non-null — a fleet with no Published generation yet boots cleanly into a UNS-less address space and fills the registry on the next restart after first publish. Ctor on OpcUaServerService gained two new dependencies (DriverEquipmentContentRegistry + IServiceScopeFactory). No test file constructs OpcUaServerService directly so no downstream test breakage — the BackgroundService is only wired via DI in Program.cs. Four new DriverEquipmentContentRegistryTests: Get-null-for-unknown, Set-then-Get, case-insensitive driver-id lookup, Set-overwrites-existing. Server.Tests 190/190 (was 186, +4 new registry tests). Full ADR-001 Option A now lives at every layer: Core.OpcUa walker (#153) → ScopePathIndexBuilder (#154) → OpcUaApplicationHost wire-in (#155) → EquipmentNamespaceContentLoader (#156) → this PR's registry + Program.cs composition. The last pending loose end (full-integration smoke test that boots Program.cs against a seeded Config DB + verifies UNS tree via live OPC UA client) isn't strictly necessary because PR #155's OpcUaEquipmentWalkerIntegrationTests already proves the wire-in at the OPC UA client-browse level — the Program.cs composition added here is purely mechanical + well-covered by the four-file audit trail plus registry unit tests.
dohertj2 created pull request dohertj2/lmxopcua#157 2026-04-20 03:52:23 -04:00
ADR-001 last-mile � Program.cs composes walker into production boot (#214)
dohertj2 deleted branch equipment-content-loader from dohertj2/lmxopcua 2026-04-20 03:21:57 -04:00
dohertj2 pushed to v2 at dohertj2/lmxopcua 2026-04-20 03:21:52 -04:00
f6d98cfa6b Merge pull request 'EquipmentNamespaceContentLoader � Config-DB loader for walker wire-in' (#156) from equipment-content-loader into v2
a29828e41e EquipmentNamespaceContentLoader — Config-DB loader that fills the (driverInstanceId, generationId) shape the walker wire-in from PR #155 consumes. Narrow follow-up to PR #155: the ctor plumbing on OpcUaApplicationHost already takes a Func<string, EquipmentNamespaceContent?>? lookup; this PR lands the loader that will back that lookup against the central Config DB at SealedBootstrap time. DI composition in Program.cs is a separate structural PR because it needs the generation-resolve chain restructured to run before OpcUaApplicationHost construction — this one just lands the loader + unit tests so the wiring PR reduces to one factory lambda. Loader scope is one driver instance at one generation: joins Equipment filtered by (DriverInstanceId == driver, GenerationId == gen, Enabled) first, then UnsLines reachable from those Equipment rows, then UnsAreas reachable from those lines, then Tags filtered by (DriverInstanceId == driver, GenerationId == gen). Returns null when the driver has no Equipment at the supplied generation — the wire-in's null-check treats that as "skip the walker; let DiscoverAsync own the whole address space" which is the correct backward-compat behavior for non-Equipment-kind drivers (Modbus / AB CIP / TwinCAT / FOCAS whose namespace-kind is native per decisions #116-#121). Only loads the UNS branches that actually host this driver's Equipment — skips pulling unrelated UNS folders from other drivers' regions of the cluster by deriving lineIds/areaIds from the filtered Equipment set rather than reloading the full UNS tree. Enabled=false Equipment are skipped at the query level so a decommissioned machine doesn't produce a phantom browse folder — Admin still sees it in the diff view via the regular Config-DB queries but the walker's browse output reflects the operational fleet. AsNoTracking on every query because the bootstrap flow is read-only + the result is handed off to a pure-function walker immediately; change tracking would pin rows in the DbContext for the full server lifetime with no corresponding write path. Five new EquipmentNamespaceContentLoaderTests using InMemoryDatabase: (a) null result when driver has no Equipment; (b) baseline happy-path loads the full shape correctly; (c) other driver's rows at the same generation don't leak into this driver's result (per-driver scope contract); (d) same-driver rows at a different generation are skipped (per-generation scope contract per decision #148); (e) Enabled=false Equipment are skipped. Server project builds 0 errors; Server.Tests 186/186 (was 181, +5 new loader tests). Once the wiring PR lands the factory lambda in Program.cs the loader closes over the SealedBootstrap-resolved generationId + the lookup delegate delegates to LoadAsync via IServiceScopeFactory — a one-line composition, no ctor-signature churn on OpcUaApplicationHost because PR #155 already established the seam.
Compare 2 commits »
dohertj2 merged pull request dohertj2/lmxopcua#156 2026-04-20 03:21:50 -04:00
EquipmentNamespaceContentLoader � Config-DB loader for walker wire-in
dohertj2 created pull request dohertj2/lmxopcua#156 2026-04-20 03:21:31 -04:00
EquipmentNamespaceContentLoader � Config-DB loader for walker wire-in
dohertj2 created branch equipment-content-loader in dohertj2/lmxopcua 2026-04-20 03:21:29 -04:00
dohertj2 pushed to equipment-content-loader at dohertj2/lmxopcua 2026-04-20 03:21:29 -04:00
a29828e41e EquipmentNamespaceContentLoader — Config-DB loader that fills the (driverInstanceId, generationId) shape the walker wire-in from PR #155 consumes. Narrow follow-up to PR #155: the ctor plumbing on OpcUaApplicationHost already takes a Func<string, EquipmentNamespaceContent?>? lookup; this PR lands the loader that will back that lookup against the central Config DB at SealedBootstrap time. DI composition in Program.cs is a separate structural PR because it needs the generation-resolve chain restructured to run before OpcUaApplicationHost construction — this one just lands the loader + unit tests so the wiring PR reduces to one factory lambda. Loader scope is one driver instance at one generation: joins Equipment filtered by (DriverInstanceId == driver, GenerationId == gen, Enabled) first, then UnsLines reachable from those Equipment rows, then UnsAreas reachable from those lines, then Tags filtered by (DriverInstanceId == driver, GenerationId == gen). Returns null when the driver has no Equipment at the supplied generation — the wire-in's null-check treats that as "skip the walker; let DiscoverAsync own the whole address space" which is the correct backward-compat behavior for non-Equipment-kind drivers (Modbus / AB CIP / TwinCAT / FOCAS whose namespace-kind is native per decisions #116-#121). Only loads the UNS branches that actually host this driver's Equipment — skips pulling unrelated UNS folders from other drivers' regions of the cluster by deriving lineIds/areaIds from the filtered Equipment set rather than reloading the full UNS tree. Enabled=false Equipment are skipped at the query level so a decommissioned machine doesn't produce a phantom browse folder — Admin still sees it in the diff view via the regular Config-DB queries but the walker's browse output reflects the operational fleet. AsNoTracking on every query because the bootstrap flow is read-only + the result is handed off to a pure-function walker immediately; change tracking would pin rows in the DbContext for the full server lifetime with no corresponding write path. Five new EquipmentNamespaceContentLoaderTests using InMemoryDatabase: (a) null result when driver has no Equipment; (b) baseline happy-path loads the full shape correctly; (c) other driver's rows at the same generation don't leak into this driver's result (per-driver scope contract); (d) same-driver rows at a different generation are skipped (per-generation scope contract per decision #148); (e) Enabled=false Equipment are skipped. Server project builds 0 errors; Server.Tests 186/186 (was 181, +5 new loader tests). Once the wiring PR lands the factory lambda in Program.cs the loader closes over the SealedBootstrap-resolved generationId + the lookup delegate delegates to LoadAsync via IServiceScopeFactory — a one-line composition, no ctor-signature churn on OpcUaApplicationHost because PR #155 already established the seam.
dohertj2 deleted branch equipment-walker-wire-in from dohertj2/lmxopcua 2026-04-20 03:11:47 -04:00
dohertj2 pushed to v2 at dohertj2/lmxopcua 2026-04-20 03:11:38 -04:00
f5076b4cdd Merge pull request 'ADR-001 wire-in � EquipmentNodeWalker in OpcUaApplicationHost (#212 + #213)' (#155) from equipment-walker-wire-in into v2
2d97f241c0 ADR-001 wire-in — EquipmentNodeWalker runs inside OpcUaApplicationHost before driver DiscoverAsync, closing tasks #212 + #213. Completes the in-server half of the ADR-001 Option A story: Task A (PR #153) shipped the pure-function walker in Core.OpcUa; Task B (PR #154) shipped the NodeScopeResolver + ScopePathIndexBuilder + evaluator-level authz proof. This PR lands the BuildAddressSpaceAsync wire-in the walker was always meant to plug into + a full-stack OPC UA client-browse integration test that proves the UNS folder skeleton is actually visible to real UA clients end-to-end, not just to the RecordingBuilder test double. OpcUaApplicationHost gains an optional ctor parameter equipmentContentLookup of type Func<string, EquipmentNamespaceContent?>? — when supplied + non-null for a driver instance, EquipmentNodeWalker.Walk is invoked against that driver's node manager BEFORE GenericDriverNodeManager.BuildAddressSpaceAsync streams the driver's native DiscoverAsync output on top. Walker-first ordering matters: the UNS Area/Line/Equipment folder skeleton + Identification sub-folders + the five identifier properties (decision #121) are in place so driver-native references (driver-specific tag paths) land ALONGSIDE the UNS tree rather than racing it. Callers that don't supply a lookup (every existing pre-ADR-001 test + the v1 upgrade path) get identical behavior — the null-check is the backward-compat seam per the opt-in design sketched in ADR-001. The lookup delegate is driver-instance-scoped, not server-scoped, so a single server with multiple drivers can serve e.g. one Equipment-kind namespace (Galaxy proxy with a full UNS) alongside several native-kind namespaces (Modbus / AB CIP / TwinCAT / FOCAS that do not have their own UNS because decisions #116-#121 scope UNS to Equipment-kind only). SealedBootstrap.Start will wire this lookup against the Config-DB snapshot loader in a follow-up — the lookup plumbing lands first so that wiring reduces to one-line composition rather than a ctor-signature churn. New OpcUaEquipmentWalkerIntegrationTests spins up a real OtOpcUaServer on a non-default port with an EmptyDriver that registers with zero native content + a lookup that returns a seeded EquipmentNamespaceContent (one area warsaw / one line line-a / one equipment oven-3 / one tag Temperature). An OPC UA client session connects anonymously against the un-secured endpoint, browses the standard hierarchy, + asserts: (a) area folder warsaw contains line-a folder as a child; (b) line folder line-a contains oven-3 folder as a child; (c) equipment folder oven-3 contains EquipmentId + EquipmentUuid + MachineCode identifier properties — ZTag + SAPID correctly absent because the fixture leaves them null per decision #121 skip-when-null behavior; (d) the bound Tag emits a Variable node under the equipment folder with NodeId == Tag.TagConfig (the wire-level driver address) + the client can ReadValue against it end-to-end through the DriverNodeManager dispatch path. Because the EmptyDriver's DiscoverAsync is a no-op the test proves UNS content came from the walker, not the driver — the original ADR-001 question "what actually owns the browse tree" now has a mechanical answer visible at the OPC UA wire level. Test class uses its own port (48500+rand) + per-test PKI root so it runs in parallel with the existing OpcUaServerIntegrationTests fixture (48400+rand) without binding or cert collisions. Server project builds 0 errors; Server.Tests 181/181 (was 179, +2 new full-stack walker tests). Task #212 + #213 closed; the follow-up SealedBootstrap wiring is the natural next pickup because the ctor plumbing lands here + that becomes a narrow downstream PR.
Compare 2 commits »
dohertj2 merged pull request dohertj2/lmxopcua#155 2026-04-20 03:11:37 -04:00
ADR-001 wire-in � EquipmentNodeWalker in OpcUaApplicationHost (#212 + #213)