Joseph Doherty 919009c5ef fix(ablegacy): stamp health from the injectable Clock; drop the redundant per-project TreatWarningsAsErrors (lmxopcua#768)
AbLegacyDriver stamped LastSuccessfulRead (init, read, write), the read's sample
timestamps and host-state change times from raw DateTime.UtcNow; only the backoff
path read the injectable Clock. All of them now read Clock(), so
NativePcccBridgeStatusHealthTests drives a manual clock (init at T0, read at T1)
and asserts LastSuccessfulRead == T1 exactly instead of spin-waiting for the wall
clock to pass the init stamp (#767). Without the driver change the 6 tests fail
(init stamp is wall-clock, not T0).

Directory.Build.props sets TreatWarningsAsErrors for every project since #766, so
the 75 per-csproj copies (64 src + 11 tests) are removed and the props comment
says it is now the only place. tools/mem-probe keeps its explicit opt-out.
Release build: 0 warnings, 0 errors; a planted CS0168 still fails the build in a
src project and in a test project that used to carry its own copy.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 13:40:07 -05:00

49 lines
2.7 KiB
XML

<Project Sdk="Microsoft.NET.Sdk">
<PropertyGroup>
<IsPackable>false</IsPackable>
<IsTestProject>true</IsTestProject>
<RootNamespace>ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests</RootNamespace>
</PropertyGroup>
<!-- OTOPCUA0001 (#595): OpcUaClientDriverWireTests call driver capabilities directly at the wire level on
purpose; the CapabilityInvoker-wrapping rule applies to production code only. -->
<PropertyGroup>
<NoWarn>$(NoWarn);OTOPCUA0001</NoWarn>
</PropertyGroup>
<ItemGroup>
<PackageReference Include="xunit.v3"/>
<PackageReference Include="Shouldly"/>
<PackageReference Include="Microsoft.NET.Test.Sdk"/>
<!-- OPC UA packages aligned at the central 1.5.378.106 (Opc.Ua.Server 1.5.378.x is now
published), so the prior VersionOverride to 1.5.374.126 is removed. The server src moved
ApplicationInstance.Start(ServerBase) → StartAsync (and the rest of the 1.5.378 async API). -->
<PackageReference Include="OPCFoundation.NetStandard.Opc.Ua.Client"/>
<PackageReference Include="OPCFoundation.NetStandard.Opc.Ua.Configuration"/>
<PackageReference Include="Microsoft.Extensions.Logging.Abstractions"/>
<PackageReference Include="xunit.runner.visualstudio">
<PrivateAssets>all</PrivateAssets>
<IncludeAssets>runtime; build; native; contentfiles; analyzers; buildtransitive</IncludeAssets>
</PackageReference>
</ItemGroup>
<ItemGroup>
<ProjectReference Include="..\..\..\src\Server\ZB.MOM.WW.OtOpcUa.OpcUaServer\ZB.MOM.WW.OtOpcUa.OpcUaServer.csproj"/>
<!-- AclKeyExpiryEnforcementTests drives the real AclRevalidationTimer (arch-review 03/S19), so the
over-the-wire denial is produced by the same component the hosted service arms rather than by
a direct call to the node manager's pass. -->
<ProjectReference Include="..\..\..\src\Server\ZB.MOM.WW.OtOpcUa.Host\ZB.MOM.WW.OtOpcUa.Host.csproj"/>
<!-- ClientAlarmMethodTests drives the real shared client against this in-process server. -->
<ProjectReference Include="..\..\..\src\Client\ZB.MOM.WW.OtOpcUa.Client.Shared\ZB.MOM.WW.OtOpcUa.Client.Shared.csproj"/>
<!-- OpcUaClientDriverWireTests drive the real OpcUaClient driver against this in-process server (#622). -->
<ProjectReference Include="..\..\..\src\Drivers\ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient\ZB.MOM.WW.OtOpcUa.Driver.OpcUaClient.csproj"/>
</ItemGroup>
<ItemGroup>
<!-- Shared bind-race retry helper for tests that boot a real SDK server on a probed port. -->
<Compile Include="..\ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests\OpcUaHostStart.cs" Link="OpcUaHostStart.cs"/>
</ItemGroup>