Passed on all four real iTNC 530 controls (Hermle49/59/70/29): Family ITnc530,
ExecutionStateName Automatic, ProgramStateName Idle, Tool/AxisName Z (and
BadNotSupported alongside Tool/AxisCode on Hermle49, which refuses R_RI 51).
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
Compared every R_RI decoder we use (22-28, 30-34, 51) byte-for-byte with pyLSV2 (MIT,
97a3d691) and ran the captured iTNC 530 replies through pyLSV2 itself: no decode
disagreement, so no published value changes.
- Additive read-only String leaves Status/ExecutionStateName, Status/ProgramStateName and
Tool/AxisName (pyLSV2 ExecState / PgmState / decode_tool_info names; out-of-table code =
"Unknown"). They ride the raw leaf's feature, so no extra wire read; raw Int32 leaves unchanged.
- Refusals: 52/72 -> BadOutOfRange, 58 -> BadTimeout, 56 -> BadInvalidState, 57 (outside the
alarm walk) -> BadNoData. IsStable and the 57-only alarm-walk end are unchanged.
Lsv2RefusalCodes names every code (pyLSV2 LSV2StatusCode) in exception/log/probe text.
- Timers 30-34 documented as uint32be seconds (lifetime counters) per pyLSV2, hardware-unproven;
TimersEnabled stays false. Axis/tool units: none on the wire, none assumed.
- Lsv2ReadOnlyPolicy untouched (pinned by a test); R_RI 20/21 left out.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
- PLC bit areas (MARKER/INPUT/OUTPUT/COUNTER/TIMER) accept 00/01/FF: real iTNC 530s
return FF for the same operands over R_DP, and pyLSV2 decodes them as non-zero = true.
02..FE stay BadDecodingError.
- New PLC:INPUT_DWORD / PLC:OUTPUT_DWORD areas (pyLSV2 MemoryType 13/12): signed
int32le, element index x 4 over the input/output-word byte pools.
- R_PR offsets agree with pyLSV2. Its count units (BYTE x2, WORD/IW as word counts)
conflict with the captured controls, so we keep the captures and pin them in a test.
- Docs: pyLSV2 correspondence table, native-operand mapping (no aliases), and why
raw R_MB is refused (pyLSV2 logs in as the write-capable PLCDEBUG role). That stays
an owner decision; Lsv2ReadOnlyPolicy is unchanged.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
- HeidenhainControlFamily + HeidenhainControlFamilies.Classify (Contracts): one authority, ported from
pyLSV2 (MIT) dat_cls.py VersionInfo.control (strip spaces, case-insensitive prefix, ITNC530 first).
Families: ITnc530, Tnc (640/620/320/128), Tnc7, Lathe (CNC PILOT 640 / MANUALplus 620), MillPlus,
LegacyTnc (426/430, not a pyLSV2 class), Unknown.
- New additive read-only leaf Controller/Family (String, Identity feature, derived from the same R_VR
reply: no extra request). Lsv2Versions.Family is computed, so record equality and the #831
identity-change rediscovery signal are unchanged. Probe message + /hosts diagnostics (<host>.family).
- DATA gate now goes through SupportsDataPath(family) (pyLSV2 client.py read_data_path is iTNC-only):
non-iTNC and Unknown => Capabilities/DataLogin Unsupported, DATA login never sent. Replaces the
"model contains itnc" substring check (same result on the real iTNC530 controls).
- No per-family selector pre-gates: pyLSV2's TNC 640 observations (27/28/51/30-34 unknown telegram,
25/26 need DNC) are already handled by the reply-driven refusal/suppression path; tests pin it.
- Lsv2ReadOnlyPolicy, HeidenhainTagWritable and the no-IWritable rule are untouched.
- Simulator: per-family ControlProfiles (strings from the pyLSV2 README tables / protocol.rst), both
R_VR field counts, 124-byte R_PR; HeidenhainControlFamilyTests (classification, gates, decoding,
wire log inside the read-only set, refused selectors asked once).
- docs/drivers/Heidenhain.md: Control families matrix (iTNC 530 hardware-proven; the rest per pyLSV2,
hardware-unproven) + open questions (C_CC buffer size, encrypted passwords, R_RI 20/21).
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
Hermle49 (iTNC 530 NC 340490 03 SP10) refuses the tool selector with code 24;
the driver correctly publishes BadNotSupported for every Tool/* leaf, so there
is no runtime type to check. The test required >0 Good leaves and failed there.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
HeidenhainSession.Leaf's `case Lsv2Tool t` switch expression mixed long, int and
double? arms, so C# unified the natural type to double? and Tool/Number (Int64),
Tool/Index and Tool/AxisCode (Int32) were published as Double. Every arm in that
switch (and in the alarm-list, axes and feature-acquire switches in the same file)
is now boxed to object explicitly so no numeric arm can widen another.
New HeidenhainLeafRuntimeTypeTests asserts value.GetType() for every catalog value
leaf against its declared DataType (scalar + array), plus PLC/DATA binding coercion
for Int16/Int32/Int64/Boolean. Verified red on the old code (exactly the three Tool
leaves) and green with the fix.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
Comms_loss_invalidates_every_remote_value_and_recovery_republishes_identical_values failed
1/40 on base 5bbe1e3c (and 1/29 on this branch): "Capabilities/Identity should be
CommunicationLost but was Supported". RetireAll -> Invalidate publishes every tag in authored
order under one lock, capability LAST, and the recorder sees each publish as it happens; the
test asserted the capability the instant the five value tags read BadNoCommunication, i.e.
before the pass's final publish. Now the wait includes the capability's CommunicationLost
(a presence the pass must produce) and additionally asserts no value went Good again during
the outage.
Second latent race fixed in the same test: Degraded holds through Backoff AND Connecting, but
the host status is Stopped only in Backoff (Unknown while a reconnect attempt is in flight),
so the test now waits for Degraded && Stopped instead of sampling whichever phase it hit.
After the fix: 79/80 filtered runs passed and 10/10 full-suite runs; the one non-pass was a vstest
"failed to connect to testhost after 90 s" host-startup timeout (the test never ran), not a test result.
- ALARM: selectors (HeidenhainAlarmSelector, Contracts): ALARM:*, ALARM:OTHER,
ALARM:CLASS=<r>[/GROUP=<r>][/NUMBER=<r>] (<r> = n | lo..hi; negative numbers allowed).
An ALARM: address and the cross-driver alarm object only work together — the factory
refuses either alone, so editor, save path, CSV and deploy inspector agree. Data type
fixed Boolean; never a value (ReadAsync BadNotSupported), never in a data subscription.
- HeidenhainDriver implements IAlarmSource: one condition per ALARM: tag at its RawPath,
driven by the SAME allowlisted R_RI 27/28 walk on the control's single loop, on the new
Polling.AlarmMs cadence (default 2000 ms, only for controls carrying an ALARM: tag).
FOCAS #647 transition rules (Raise / Retrigger / Clear), identity = class+group+number+text,
deterministic display order, told-record on the driver instance, recorded only while a
handler listens. A failed walk (refusal, overflow, comms loss) is quality-only, never a clear.
- Acknowledge is LOCAL-ONLY: AcknowledgeAsync is a no-op success (FOCAS/MTConnect posture);
Lsv2ReadOnlyPolicy is unchanged — no ack or write request exists.
- Opt-in per tag, no driver flag (FOCAS #647 / MTConnect #626 precedent); Alarms/* arrays unchanged.
- IRediscoverable: a reconnect whose R_VR identity (model / NC / PLC / options) differs from
the previous session raises OnRediscoveryNeeded once (advisory re-browse chip). No extra traffic.
- AdminUI: Heidenhain joins NativeAlarmModel's alarm drivers; the typed editor fixes ALARM:
tags at Boolean and seeds/drops the alarm object with the selector; driver form gains
"Alarm conditions (ms)". (HeidenhainDriverFormModel also carries the #830 credential-notice change.)
Tests: HeidenhainAlarmTests (grammar, pairing, rules, simulator e2e with the captured iTNC 530
alarm record, local-only ack = zero bytes sent, quality-only outage/refusal, rediscovery),
Runtime.Tests HeidenhainNativeAlarmEndToEndTests (real DriverHostActor condition), a
DraftValidator case, and the NativeAlarmDriverSetGuard now scans the Heidenhain driver.
- Credential exfiltration (review 2): password references are scoped to
secret:heidenhain/<name> and env:OTOPCUA_HEIDENHAIN_<NAME> only. Enforced by
HeidenhainOptionsParser.TryParseCredentialReference (parser, probe, deploy gate) AND again at
resolve time in HeidenhainCredentials (fail closed without consulting the store or the
environment), so Test Connect can no longer send env:ConnectionStrings__ConfigDb or another
subsystem's secret to an arbitrary Host. The probe also refuses an unsendable password.
- Optional-role credentials (review 6): an unresolvable/NUL/non-Latin-1/>247-byte DNC or DATA
credential never sends a login and never fails the session; the reads needing that role are
BadConfigurationError (capability ConfigurationError) and INSPECT telemetry continues. A
policy refusal inside AcquireAsync is per-tag, not a session teardown.
- Start after DisposeAsync is a no-op (review 3); initial subscription push and Publish are
ordered under one lock (review 4); JSON-null sections are normalised and the acquisition loop
catches every fault (review 5); backoff resets only after a session published a poll batch,
with clamped delays (review 7).
Tests: HeidenhainReviewFixTests + namespace/normalisation tests in HeidenhainConfigTests;
each was confirmed red against the reverted fix.
Native LSV2 TCP transport (default port 19000; no Java/Python/vendor SDK), ported from
the ignitionoee v0.20.3 reference driver:
- Lsv2ReadOnlyPolicy: payload-aware outbound allowlist (A_LG INSPECT/DNC/DATA, R_VR, R_PR,
R_RI 22-28/30-34/51, bounded R_MB, R_DP), applied in Lsv2Codec.Frame before any byte is
written; no public raw-command API.
- Lsv2Client: serialized transactions, one monotonic deadline per transaction, EOF/oversize/
unexpected/trickle close the client; Close never waits on the gate.
- Lsv2Data / HeidenhainBindingCodec: reference decoders, R_PR byte-capacity + element-index
rules, next-area cap, DATA Boolean 00/01/FF, strict non-truncating coercion.
- HeidenhainSession: per-batch wire cache, refusal suppression, provisional DNC denial retry,
alarm cursor (57 = end, overflow = BadOutOfRange), capability strings.
- HeidenhainDeviceRuntime: one loop per control, generation-guarded publication, all-node
BadNoCommunication on comms loss, bounded exponential reconnect.
- HeidenhainDriver: cached ReadAsync, push subscriptions deduped on (value,status), static
catalog discovery (no connect), host status, diagnostics, skipped-tag report. No IWritable.
- Probe (INSPECT login + version) and factory registered in DriverFactoryBootstrap (probe on
admin nodes too); DriverTypeNames.Heidenhain.
Tests: 159 unit tests against an in-process LSV2 simulator incl. the Java fixtures' captured
iTNC 530 replies as golden vectors; env-gated LiveIntegration category for real hardware.