Commit Graph

291 Commits

Author SHA1 Message Date
Joseph Doherty 86ca1a76d1 feat(driver-calc): T0-4 Calculation evaluator core + project
New Driver.Calculation project + CalculationEvaluator, mirroring the
VirtualTag RoslynVirtualTagEvaluator: source-hash compile cache
(CompiledScriptCache), 2 s TimedScriptEvaluator, passthrough fast-path,
single-tag mode (ctx.SetVirtualTag dropped + logged), sandbox/compile/
timeout/throw all surfaced as VirtualTagEvalResult.Failure for WP7 to map
to Bad quality. IScriptCacheOwner.ClearCompiledScripts for the deploy
generation boundary. 11 parity unit tests. Both projects added to the
solution. Evaluator + tests only — driver shell / registration is WP7.

Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
2026-07-16 02:07:38 -04:00
Joseph Doherty a4c61989b2 test(v3): migrate 6 driver IntegrationTests to RawTags API
Replace pre-declared options.Tags (typed <Driver>TagDefinition lists) with
options.RawTags (IReadOnlyList<RawTagEntry>) across all 6 Docker-gated driver
integration suites so they COMPILE against the v3 driver API.

Each project gets a local <Driver>RawTags helper mirroring the unit-test
project's helper: it serialises a typed def back to its TagConfig blob via the
driver's <Driver>TagDefinitionFactory.ToTagConfig and packages it as a
RawTagEntry (RawPath = def.Name; DeviceName = def.DeviceHostAddress for the
multi-device drivers AbCip/AbLegacy/TwinCAT/FOCAS). Test intent (addresses,
data types, device routing, assertions) is unchanged — only the
tag-authoring/config-delivery shape was migrated.

Docker-gated: these still skip at runtime without fixtures; COMPILE is the gate.
2026-07-15 20:59:42 -04:00
Joseph Doherty bd9d47eeae Merge B1-galaxy: v3 RawPath read-path 2026-07-15 20:20:49 -04:00
Joseph Doherty 8794991592 Merge B1-opcuaclient: v3 RawPath read-path 2026-07-15 20:20:49 -04:00
Joseph Doherty 53167624ae Merge B1-focas: v3 RawPath read-path 2026-07-15 20:20:49 -04:00
Joseph Doherty 7c2f28313d Merge B1-twincat: v3 RawPath read-path 2026-07-15 20:20:49 -04:00
Joseph Doherty 63b7d6ca5d Merge B1-ablegacy: v3 RawPath read-path 2026-07-15 20:20:49 -04:00
Joseph Doherty 1748af7261 Merge B1-abcip: v3 RawPath read-path 2026-07-15 20:20:49 -04:00
Joseph Doherty 8b2c3fa04c v3(focas): adopt Modbus RawTagEntry exemplar (multi-device)
- Rename FocasEquipmentTagParser -> FocasTagDefinitionFactory; TryParse ->
  FromTagConfig(tagConfig, rawPath, out def). Drop leading-{ heuristic + the
  deviceHostAddress blob key; def.Name = rawPath. Add inverse ToTagConfig.
  writable: absent -> read-only, explicit true honoured (note preserved).
- FocasDriverOptions.Tags -> RawTags (IReadOnlyList<RawTagEntry>).
- FocasDriver: _tagsByRawPath (Ordinal); byName-only resolver; build table from
  RawTags via FromTagConfig; multi-device routing threads RawTagEntry.DeviceName
  -> ResolveDeviceHost match against options.Devices -> def.DeviceHostAddress
  (TODO v3 WaveC: live host from Device row DeviceConfig). Tolerant per-tag
  skip+log (mapper/address/matrix miss -> BadNodeIdUnknown); unknown device
  fails init fast.
- Factory: bind List<RawTagEntry> RawTags; retire FocasTagDto/ParseDataType.
- CLI FocasCommandBase.BuildOptions -> RawTags via ToTagConfig + DeviceName.
- Tests: FocasRawTags helper; migrate Tags= -> RawTags=; rename parser tests to
  FromTagConfig; rewrite retired blob-ref tests (equipment-tag/capability-gate/
  resolve-host) onto authored RawPath. 272 driver + 52 CLI green.
2026-07-15 20:19:55 -04:00
Joseph Doherty c0379742bc v3(b1-abcip): RawPath read-path for AbCip (multi-device)
Apply the reviewed Modbus exemplar to the AbCip multi-device driver:
- Mapper AbCipEquipmentTagParser -> AbCipTagDefinitionFactory; TryParse -> FromTagConfig(tagConfig, rawPath, out def); drop leading-{ heuristic + the deviceHostAddress key; add inverse ToTagConfig; round-trip arrays/members/safety for coverage.
- Options: Tags (typed) -> RawTags (RawTagEntry list); Devices list kept.
- Driver: byName-only resolver over _tagsByRawPath (Ordinal); table built from RawTags via FromTagConfig, threading entry.DeviceName (device routing key) + entry.WriteIdempotent onto the def. Multi-device routing keys on DeviceName-or-host via a _devicesByRoutingKey index; discovery groups _declaredTags by RoutesToDevice.
- Factory: retire the pre-declared Tags DTO/BuildTag; bind List<RawTagEntry> RawTags.
- Probe: derive probe tag path from RawTags via the mapper.
- Cli BuildOptions projects typed tags -> RawTagEntry (ToTagConfig).
- Tests: AbCipRawTags helper (typed def -> RawTagEntry); parser tests -> FromTagConfig; blob-fallback driver tests rewritten to author via RawTags + read by RawPath. Driver.AbCip.Tests 342/342, Cli.Tests 42/42.

TODO(v3 WaveC): DeviceName becomes a pure logical name once the device connection host moves to the Device row's DeviceConfig.
2026-07-15 20:18:28 -04:00
Joseph Doherty 636c755b04 v3(galaxy): re-key GalaxyDriver to RawPath identity (dial attributeRef)
Wave-B driver re-keying. Under v3 the server addresses Galaxy nodes by RawPath
and the driver dials the Galaxy attributeRef (tag_name.AttributeName). The
dialled address moved into TagConfig under the camelCase key `attributeRef`
(renamed from the pre-v3 PascalCase FullName) and rides on RawTagEntry.

Options + factory:
- GalaxyDriverOptions gains `IReadOnlyList<RawTagEntry> RawTags` (Contracts now
  references the zero-dep Core.Abstractions leaf for RawTagEntry — same as
  Modbus.Contracts). Factory binds `List<RawTagEntry>? RawTags` from DriverConfig.

Boundary translation (built once from options.RawTags):
- RawPath -> attributeRef (forward dial) on Read / Write / Subscribe / Ack.
- attributeRef -> RawPath (reverse) on the value fan-out (OnDataChange) and the
  alarm ConditionId — so the alarm resolves back to the same RawPath the value
  path surfaces. Both legs fall back to identity on a miss, so the live-browse
  discovery path (no authored tags) and synthetic alarm sub-refs
  (attributeRef.InAlarm) dial straight through unchanged.
- WriteAsync dials the attributeRef but resolves security via the RawPath-keyed
  map the discoverer captured (reverse-maps in the resolver closure).

Discovery + alarms:
- GalaxyDiscoverer emits FullName = RawPath for authored attributes (falls back
  to attributeRef), threads RawTagEntry.WriteIdempotent onto DriverAttributeInfo,
  and gains an optional attributeRef -> RawTagEntry resolver ctor param.
- AlarmRefBuilder.Build(conditionReference, dialReference): SourceName/ConditionId
  = RawPath identity; the five live-state/ack sub-refs dial off the attributeRef.

ReinitializeAsync equivalence now compares the session-shape sections field-wise,
excluding RawTags (address-space state re-applied via rediscovery, and a record's
synthesized equality would compare the lists by reference).

Tests: +9 (discoverer RawPath/WriteIdempotent + alarm identity; factory RawTags
binding; driver read/write/subscribe/alarm boundary translation). Existing 304
preserved via identity fallback. 313 pass, 5 live-gated skips.
2026-07-15 20:12:22 -04:00
Joseph Doherty ec01649905 v3(b1-opcuaclient): re-key OpcUaClient resolution to RawPath via RawTags
NamespaceMap now carries a RawPath -> upstream node id table built from the
deployed RawTagEntry list (reads each tag's TagConfig.nodeId, threads
WriteIdempotent). Under v3 the read/write/subscribe/history reference handed to
the driver is the tag's RawPath identity; the driver resolves it in two stages:
RawPath -> nodeId string (instance TryResolve) -> live NodeId re-bound against
the session (static TryResolve). Alarm ConditionId + event-history sourceName
stay on the direct session parse (they are upstream node ids, not RawPaths).

- Options: add IReadOnlyList<RawTagEntry> RawTags (Contracts now refs Core.Abstractions).
- Factory: RawTags binds straight into options (no separate DTO); EndpointUrl kept.
- Browser: unchanged (emits neutral BrowseNode DTOs, no TagConfig FullName key).
- Tests: 138 green; new RawPath resolution + factory-binding coverage; migrated
  the stale-session ReadRaw test to author a resolving RawTag.

Contracts + Driver + Browser build clean (0 warn). Wave C wires endpoint->DeviceConfig
and the deploy artifact that populates RawTags.
2026-07-15 20:11:44 -04:00
Joseph Doherty a53be2af65 v3(b1-twincat): apply Modbus exemplar pattern to TwinCAT (multi-device)
- Rename TwinCATEquipmentTagParser -> TwinCATTagDefinitionFactory; TryParse ->
  FromTagConfig(tagConfig, rawPath, out def). Drop leading-'{' heuristic + the
  deviceHostAddress key; def.Name = rawPath. Keep strict-enum + Inspect; add a
  Structure guard (sole tag path now) + inverse ToTagConfig.
- Options: Tags -> RawTags (RawTagEntry); keep Devices + protocol fields.
- Driver: _tagsByRawPath (Ordinal); byName-only resolver; build table from
  _options.RawTags via FromTagConfig, threading WriteIdempotent + DeviceName.
  Multi-device: ResolveDeviceHost matches entry.DeviceName against options.Devices
  (by name, then host) -> def.DeviceHostAddress (TODO(v3 WaveC): live host from the
  Device row's DeviceConfig). DiscoverAsync now emits from the table.
- Factory: retire pre-declared tags[] DTO path; bind rawTags; keep Devices.
- Cli: BuildOptions serialises typed defs -> RawTagEntry via ToTagConfig.
- Tests: TwinCATRawTags helper; migrate Tags= -> RawTags=; rename parser tests to
  FromTagConfig; equipment/resolve-host/array tests delivered via RawTags.

Gate: Contracts + Driver build green; Driver.TwinCAT.Tests 192 pass, Cli.Tests 70 pass.
2026-07-15 20:11:23 -04:00
Joseph Doherty 1e26b9ab58 v3(s7): apply Modbus RawTags exemplar to the S7 driver
Rename S7EquipmentTagParser -> S7TagDefinitionFactory; TryParse(reference)
-> FromTagConfig(tagConfig, rawPath, out def) (drops the leading-{ heuristic,
keys the def by RawPath, adds inverse ToTagConfig). Replace S7DriverOptions.Tags
(pre-declared S7TagDefinition list) with RawTags (IReadOnlyList<RawTagEntry>);
the driver builds its RawPath->def table from RawTags at Initialize via the
factory (skip+log on miss), resolver is byName-only, DiscoverAsync + init guards
+ address pre-parse now run off that table. Factory retires the pre-declared DTO
tag path (RawTags binding only). Cli BuildOptions serialises typed defs to
RawTagEntry. Tests migrated to a S7RawTags helper + FromTagConfig; parser test
files renamed. Coordinator's EquipmentTagConfigInspector S7 rename left to Wave-B
coordinator; Driver.S7.IntegrationTests (Docker-gated) left red per scope.

Driver.S7 + Cli build green; Driver.S7.Tests 264/264, S7.Cli.Tests 49/49.
2026-07-15 20:11:04 -04:00
Joseph Doherty 3878b51e97 v3(ablegacy): apply Modbus exemplar — RawTags delivery + RawPath mapper
- Rename AbLegacyEquipmentTagParser → AbLegacyTagDefinitionFactory; TryParse →
  FromTagConfig(tagConfig, rawPath, out def). Drop the leading-{ heuristic and the
  deviceHostAddress key; def.Name = rawPath. Add inverse ToTagConfig. Keep strict-enum
  guards + Inspect.
- Options: Tags(IReadOnlyList<AbLegacyTagDefinition>) → RawTags(IReadOnlyList<RawTagEntry>).
- Driver: _tagsByRawPath (Ordinal); byName-only resolver; build table from _options.RawTags
  via FromTagConfig, threading WriteIdempotent + resolving RawTagEntry.DeviceName to the
  owning device host (ResolveDeviceHost; TODO(v3 WaveC) for the live Device-row host).
  DiscoverAsync + family-profile validation iterate the built table. Probe picks its address
  from RawTags via the mapper.
- Factory: retire the pre-declared tag DTO path; bind List<RawTagEntry>? RawTags; keep Devices.
- Cli BuildOptions: deliver typed defs as RawTagEntry via ToTagConfig.
- Tests: AbLegacyRawTags helper; migrate Tags= → RawTags; parser tests → FromTagConfig;
  equipment-ref driver/ResolveHost tests re-authored as RawTagEntry + read by RawPath.

Driver+Contracts+Cli green; 213 driver + 36 Cli tests pass.
2026-07-15 20:09:46 -04:00
Joseph Doherty aafb9d4929 v3(b1-modbus): RawPath identity seam — RawTagEntry-driven Modbus driver
Wave-B EXEMPLAR. Retire the pre-declared/blob-parse tag model; the driver now
builds its RawPath -> definition table from the artifact's RawTagEntry set via a
pure mapper.

- Contracts: rename ModbusEquipmentTagParser -> ModbusTagDefinitionFactory;
  TryParse(reference) -> FromTagConfig(tagConfig, rawPath) (def.Name = rawPath,
  no leading-brace heuristic); add inverse ToTagConfig(def) serializer; keep all
  strict-enum reads + guards; also read stringByteOrder/deadband/coalesceProhibited
  so a RawTagEntry round-trips the full authored def. Inspect() unchanged.
- Options: Tags(IReadOnlyList<ModbusTagDefinition>) -> RawTags(IReadOnlyList<RawTagEntry>).
- Driver: _tagsByName -> _tagsByRawPath (Ordinal); resolver byRawPath-only; build
  the table from RawTags at Initialize threading entry.WriteIdempotent onto each def;
  Discover/Teardown updated.
- Factory: remove ModbusTagDto/BuildTag/ValidateStringLength + ConfigDto.Tags; bind
  RawTags from driver-config JSON.
- CLI ModbusCommandBase.BuildOptions: serialise typed defs -> RawTagEntry via ToTagConfig.
- Tests: migrate Tags= -> RawTags via ModbusRawTags.Entries helper; parser tests ->
  FromTagConfig(rawPath); factory String-length/enum tests re-seated on the mapper seam.
- Propagated rename to ControlPlane EquipmentTagConfigInspector (outside Modbus projects).

Modbus.Tests 315/315, Addressing.Tests 161/161, Cli.Tests 72/72 green.
Docker-gated Driver.Modbus.IntegrationTests left untouched (won't compile against
the new API; expected).
2026-07-15 19:50:10 -04:00
Joseph Doherty 679484ae78 feat(browse): Wave-0 Batch B — AbCip/TwinCAT/FOCAS opt into online discovery
Task 3/4/5: SupportsOnlineDiscovery => true on AbCipDriver, TwinCATDriver, FocasDriver
(their device enumeration is real, config-gated on EnableControllerBrowse / FixedTree.Enabled
which PatchForBrowse guarantees at open). One gate fact per driver test project.
2026-07-15 17:18:02 -04:00
Joseph Doherty e8db0a683f fix(drivers): flip runtime tag parsers to strict enum parsing (#457)
v2-ci / build (pull_request) Successful in 4m12s
v2-ci / unit-tests (pull_request) Failing after 10m15s
R2-11 Phase C. All six equipment-tag parsers (Modbus/S7/AbCip/AbLegacy/
TwinCAT/Focas) now read enum fields via the new TagConfigJson.TryReadEnumStrict:
absent -> fallback, valid -> parsed, present-but-invalid (typo) -> TryParse
returns false -> EquipmentTagRefResolver.TryResolve false -> driver surfaces
BadNodeIdUnknown, instead of the old lenient path that silently defaulted a
typo to a wrong-width Good.

Modbus flips all three enum fields (region/dataType/byteOrder); the other five
flip dataType. The deploy-time Deployment:TagConfigValidationMode=Error gate is
unchanged and remains the operator pre-flight.

Coverage:
- Six *EquipmentTagParserStrictnessTests inverted from Freeze_typo_* (lenient)
  to Typo_*_rejects_the_tag + Valid_*_still_parses.
- TagConfigJsonTests.TryReadEnumStrict_rejects_only_invalid matrix.
- Driver-level end-to-end proof:
  AbCipEquipmentTagTests.Driver_read_of_a_typod_dataType_ref_surfaces_BadNodeIdUnknown
  drives the real AbCipDriver.ReadAsync through resolve->status.

Golden parity corpus has no typo'd enums, so the flip is a no-op there.
Full solution builds clean; all six driver suites + core + parity + gate green.
2026-07-15 11:28:34 -04:00
Joseph Doherty a5a0f96d49 fix(drivers): harden operator TimeoutMs handling + AbLegacy evict parity
v2-ci / build (pull_request) Successful in 4m5s
v2-ci / unit-tests (pull_request) Failing after 10m45s
Follow-ups from the fleet-wide read-timeout audit that the S7 R2-01 read-leg
fix (PR #453) prompted. The audit confirmed S7 was the ONLY driver with the
async-read-ignores-socket-timeout hang; these are the two adjacent (non-hang)
findings it surfaced.

1. FOCAS TimeoutMs:0 footgun (the risky one): a non-positive Timeout made
   SynchronizedFocasClient DISABLE its per-call wall-clock ceiling, reverting to
   the caller's long-lived poll token — reintroducing exactly the frozen-peer
   wedge S7 just eliminated, under misconfig. Clamp non-positive TimeoutMs to the
   2s default at the config boundary so the deadline can never be authored away.

2. TimeoutMs validation symmetry: apply the same clamp in the AbCip + AbLegacy
   factories. libplctag's Tag.Timeout setter throws on <=0, faulting tag creation
   on every read/write; clamping keeps a misconfigured TimeoutMs:0 running on the
   default bound instead. (Shared PositiveTimeoutOrDefault helper per factory.)

3. AbLegacy reconnect parity with AbCip: AbLegacy evicted the cached libplctag
   runtime on neither the non-zero-status nor transport-exception read/write path
   (AbCip evicts on both), so a data-path fault recovered only via the probe loop
   / libplctag internals. Added EvictRuntime + wired it into both read and write
   failure paths so a fresh handle is created on the next call.

Tests: FOCAS 265->269 (clamp theory + positive), AbCip 336->339 (clamp theory +
positive), AbLegacy 209->212 (read-nonzero / read-exception / write-nonzero evict).
No production regressions; all three driver suites green.
2026-07-15 07:35:17 -04:00
Joseph Doherty 88e0977ae6 fix(s7): bound async wire ops with a wall-clock deadline (R2-01 read leg)
v2-ci / build (pull_request) Successful in 5m5s
v2-ci / unit-tests (pull_request) Failing after 13m50s
The R2-01 live gate (S7_1500ConnectTimeoutOutageTests, docker-pause blackhole)
surfaced a real gap the offline fakes couldn't: S7.Net's ReadTimeout/WriteTimeout
map to the TcpClient's ReceiveTimeout/SendTimeout, which govern only SYNCHRONOUS
socket calls — the async read/write paths S7.Net uses ignore them. On an
established-but-frozen peer (frozen PLC / firewall DROP / cable pulled mid-flow,
TCP session still open) a read blocked until the OS TCP stack gave up (minutes),
silently wedging the poll loop: no Bad tick, no reconnect. STAB-14 fixed only the
CONNECT leg (EnsureConnectedAsync CancelAfter); this is its READ-leg sibling.

- New S7OperationDeadline: bounds every data-plane wire op with a wall-clock
  ceiling (= _options.Timeout), surfacing an overrun as TimeoutException. Applied
  in S7PlcAdapter to Read/ReadBytes/Write/WriteBytes/ReadStatus. OpenAsync is left
  to EnsureConnectedAsync's own CancelAfter (not double-bounded).
- IsS7ConnectionFatal now classifies TimeoutException fatal → handle marked dead →
  next EnsureConnectedAsync reopens (connect-timeout fix takes over from there).
- Tests: 5 S7OperationDeadline unit tests (deadline / token-honouring / caller-
  cancel-passthrough / resultless), 1 driver-reaction test (read TimeoutException
  → reopen). Driver.S7.Tests 260/260.
- Live gate S7_1500ConnectTimeoutOutageTests now GREEN against the real snap7 sim
  (8s: baseline Good -> pause blackhole -> Bad tick -> unpause -> recovered Good).
2026-07-15 07:11:42 -04:00
Joseph Doherty 7982043673 fix(focas-tests): honour fixture endpoint + fix mock timer endianness (9F/1P -> 10/10)
v2-ci / build (pull_request) Successful in 4m31s
v2-ci / unit-tests (pull_request) Failing after 10m26s
Two test/fixture bugs; NO OtOpcUa driver change.

1. Topology: FocasSimFixture reads an env-overridable endpoint
   (OTOPCUA_FOCAS_SIM_ENDPOINT, default localhost:8193) and exposes Host/Port,
   but WireBackendTests + WireBackendCoverageTests hardcoded
   focas://127.0.0.1:8193. Against a remote fixture the skip-gate passed
   (remote reachable) but the driver dialed localhost -> KeyNotFound. Added a
   DeviceUri property to the fixture; each test now derives DeviceHost from it.
   Recovered 8 of 9.

2. Mock timer endianness (surfaced once #1 let the tests reach the mock): the
   last failure read 60397977600 for a 3600 s power-on timer (= 0x3C000000 x 60).
   The focas-mock's _wire_timer encoded the minute/msec fields big-endian (_u32),
   but cnc_rdtimer's timer fields are LITTLE-endian on real hardware — a
   documented, live-31i-B-validated quirk that FocasWireClient.ParseTimer decodes
   LE (docs/plans/2026-06-25-focas-pdu-v3-30i-b-support.md). The driver was
   correct; the mock was wrong. _wire_timer now emits little-endian (_u32_le).

Suite 9F/1P -> 10/10 against the remote fixture at ~/otopcua-focas.
Integration-sweep follow-up #3.
2026-07-15 05:51:47 -04:00
Joseph Doherty 00f39c849e docs(modbus-tests): document profile-cycling gotcha; sweep #2 was a false alarm
v2-ci / build (pull_request) Successful in 4m13s
v2-ci / unit-tests (pull_request) Failing after 9m41s
The 2026-07 integration sweep flagged the Modbus non-standard profiles as
8F/5F/3F/8F and guessed 'pymodbus 4.x drift'. Re-investigation shows that was
wrong on both counts:

- The image runs the PINNED pymodbus 3.13.0 (verified via import pymodbus;
  __version__). The '...removed in v4' log is 3.13.0's forward-deprecation
  warning, misread as running 4.x.
- The failures were a fixture-cycling artifact: each profile is a separate
  profile-gated compose service sharing :5020, and a plain 'docker compose down'
  (no --profile) does NOT stop the running profile container. It kept holding
  :5020; the next '--profile up' container silently failed to bind (compose
  still says 'Started'), so every later profile run hit the STALE sim. Proven by
  a raw Modbus probe: the 'mitsubishi' sim served DL205's 0xCAFE at HR0.

After force-removing all modbus containers and bringing up each profile cleanly
(verifying it actually published :5020), all four pass: dl205 16/16,
mitsubishi 13/13, s7_1500 10/10, exception_injection 17/17. No OtOpcUa or test
code change needed.

Added a profile-cycling gotcha + reliable-cycle recipe to Docker/README.md and
corrected the sweep record. Integration-sweep follow-up #2.
2026-07-15 05:12:52 -04:00
Joseph Doherty 326b22a7ba fix(abcip-tests): expression-body KnownProfiles.All to fix static-init NRE
KnownProfiles.All used a { get; } = [...] initialiser declared textually
before the static readonly profile fields it references, so C# static-init
order captured an all-null list. ForFamily() then NRE'd on p.Family, faulting
AbServerFixture..ctor and blocking the whole AbCip.IntegrationTests suite.

Expression-body it so it evaluates on access, after the fields are set.
Live-verified against the controllogix fixture: suite goes 6F/1P/3skip ->
10 pass / 0 fail / 3 skip (skips = emulator-mode tests).

Integration-sweep follow-up #1 (archreview/plans/INTEGRATION-SWEEP-STATUS.md).
2026-07-15 03:28:04 -04:00
Joseph Doherty 9f62310b49 fix(historian): map Boolean historization to Int2, not degenerate Int1 (#441)
v2-ci / build (pull_request) Successful in 3m24s
v2-ci / unit-tests (pull_request) Failing after 8m19s
The historian's Int1 analog-tag creation path is server-degenerate:
EnsureTags(Int1) stores an unusable stub (live-probed on the deployed
2023 R2 historian; root-caused + documented gateway-side in
HistorianGateway #11 / PR #16). HistorianTypeMapper mapped
DriverDataType.Boolean -> HistorianDataType.Int1, so Boolean historized
tags failed auto-provisioning.

Map Boolean -> Int2 instead (store 0/1). Int2 is a proven-creatable
analog type, and the value-write path already sends every value as a
double on WriteLiveValues regardless of tag type, so Boolean 0.0/1.0
round-trips cleanly. Both Float and Int2 are supported, so a
pre-existing Float Boolean tag retypes cleanly on its next deploy.

- HistorianTypeMapper: Boolean => Int2 (+ remarks)
- Unit pins: HistorianTypeMapperTests, GatewayTagProvisionerTests
  (Boolean_definition_carries_explicit_Int2_presence)
- Live gate: EnsureTags_boolean_sandbox_provisions_as_Int2 (was _Int1);
  retype probe reframed Float->Int2 (drops the dead Int1 leg)
- Docs: docs/Historian.md 'Boolean historization maps to Int2', CLAUDE.md,
  archreview STATUS.md (R2-06 live gate -> 6/6)

Resolves #441.
2026-07-14 11:57:27 -04:00
Joseph Doherty 4da2d62b9a fix(historian): stamp a positive StorageRateMs on provisioned tags
v2-ci / build (pull_request) Successful in 4m7s
v2-ci / unit-tests (pull_request) Failing after 10m50s
GatewayTagProvisioner built HistorianTagDefinition without a StorageRateMs, so
the proto uint32 defaulted to 0. The gateway's EnsureTags maps StorageRateMs
straight to the AVEVA SDK's storageRateMs, which requires a positive value —
0 makes the SDK throw ArgumentOutOfRangeException ('Storage rate must be > 0 ms'),
so EVERY historized-tag auto-provision (the deploy-time IHistorianProvisioning
hook) silently failed at the gateway with failed=N.

Stamp DefaultStorageRateMs=1000 (matches the gateway's own live provisioner
convention; quantized 1000/5000/10000). Add a regression unit test asserting the
definition carries a positive rate, and set StorageRateMs on the live-suite's
inline definitions so the retype probe reaches a real EnsureTags.

Found via the R2-06 live gate against a real 0.2.0 gateway + AVEVA historian:
with this fixed, Float/Int2/UInt2/Int4/UInt4/Double all provision and the live
suite goes 3/6 -> 5/6. (Int1/Boolean remains blocked by the gateway histsdk's
ProtocolEvidenceMissingException for Int1 — a gateway-side type-support gap, not
this bug.)

Gateway driver unit 103/103.
2026-07-13 19:29:49 -04:00
Joseph Doherty 56ddf45e1c chore(core): flatten Historian sub-namespace to Core.Abstractions root
v2-ci / build (pull_request) Successful in 4m32s
v2-ci / unit-tests (pull_request) Failing after 10m2s
Four continuous-historization types (IHistorizationOutbox, HistorizationOutboxEntry,
IHistorianValueWriter/HistorizationValue, HistorizationCommitMode) drifted into a
ZB.MOM.WW.OtOpcUa.Core.Abstractions.Historian sub-namespace while the other six files
in the same folder correctly use the root namespace. This violated decision #59's
flat-public-surface rule and left InterfaceIndependenceTests.AllPublicTypes_LiveInRootNamespace
red on master (pre-existing, predates round-2 remediation).

Move all four to the root namespace and drop/retarget the now-redundant
'using ...Core.Abstractions.Historian;' in the ~11 consumers. No behavioral change.

Verified: Core.Abstractions.Tests 129/129 (was 128/129), Runtime.Tests Historian+DI 72/72,
Gateway driver unit 102/102, full solution build 0 errors.
2026-07-13 18:29:01 -04:00
Joseph Doherty 6ee74d26fc docs(r2-09): record execution deviations; clear CS8604 nullable warning in the 5 PollErrorHealthTests
v2-ci / build (pull_request) Successful in 3m32s
v2-ci / unit-tests (pull_request) Failing after 9m27s
2026-07-13 12:45:50 -04:00
Joseph Doherty 502a327f25 fix(twincat): probe recycle honors cancellation — no uncancellable gate wait (05/STAB-12 compounded part); B6 complete (TwinCAT suite 189 green) 2026-07-13 12:43:06 -04:00
Joseph Doherty 082ee99b6b fix(twincat): retract the fresh ADS notification when unsubscribe raced the replay (05/STAB-17) 2026-07-13 12:39:39 -04:00
Joseph Doherty de29759643 fix(twincat): retry failed replay intents on the next successful probe tick (05/STAB-16) 2026-07-13 12:37:20 -04:00
Joseph Doherty 4f16620948 test(twincat): failing repro for STAB-16 silent replay failure 2026-07-13 12:33:35 -04:00
Joseph Doherty e69d3b3b0f fix(modbus): equipment tags carry unitId; ResolveHost keys per-unit via the resolver (CONV-4) 2026-07-13 12:29:13 -04:00
Joseph Doherty 9262dd25b7 fix(drivers): ResolveHost resolves equipment-tag refs via EquipmentTagRefResolver — per-host breaker isolation (CONV-4) 2026-07-13 12:26:42 -04:00
Joseph Doherty 8a7701db3f test(drivers): failing repro for CONV-4 equipment-tag ResolveHost mis-keying 2026-07-13 12:23:43 -04:00
Joseph Doherty 86742ad8cb fix(abcip): throttle evict-recreate Forward-Open attempts per device (05/STAB-8) 2026-07-13 12:20:10 -04:00
Joseph Doherty e54af9b948 fix(focas): per-device connect-attempt backoff across the three loops (05/STAB-8) 2026-07-13 12:16:31 -04:00
Joseph Doherty 962afed241 fix(twincat): per-device connect-attempt backoff, probe-driven recovery (05/STAB-8) 2026-07-13 12:13:23 -04:00
Joseph Doherty 85ef74ea86 refactor(s7): retire the bespoke poll fork onto PollGroupEngine v2 (CONV-1; fixes PERF-3 + STAB-6-S7; deletes the fork's bare-OCE poll-death — cross-ref plan R2-01) 2026-07-13 12:07:39 -04:00
Joseph Doherty 0d879363f8 test(s7): failing guards for the poll-fork retirement (PERF-3, STAB-6) 2026-07-13 12:05:08 -04:00
Joseph Doherty b494d09d9b fix(drivers): wire PollGroupEngine onError->health + 30s poll backoff (05/STAB-9) [twincat,focas] 2026-07-13 11:59:49 -04:00
Joseph Doherty 9213c037b0 fix(drivers): wire PollGroupEngine onError->health + 30s poll backoff (05/STAB-9) [modbus,abcip,ablegacy] 2026-07-13 11:57:25 -04:00
Joseph Doherty bb8386d126 test(focas): failing repro for STAB-5 cross-thread Dictionary mutation 2026-07-13 11:46:12 -04:00
Joseph Doherty 32f248c93d test(abcip): failing repro for STAB-4 unserialized shared-handle ops 2026-07-13 11:40:17 -04:00
Joseph Doherty 141c143586 test(modbus): failing repro for STAB-3 timeout/framing stream desync 2026-07-13 11:35:20 -04:00
Joseph Doherty 1a698cbb97 Merge R2-11 TagConfig consolidation (arch-review round 2) [PR #434]
v2-ci / build (push) Successful in 3m55s
v2-ci / unit-tests (push) Failing after 8m14s
Findings 01/C-1, 01/P-1 (single TagConfigIntent.Parse in Commons, 4 copies
delegate, parse-once) + 05 CONV-2/UNDER-1/UNDER-6 (shared strict TagConfigJson
readers, per-driver Inspect() + writable key, FOCAS capability pre-flight,
Modbus probe timeoutMs, deploy-gate Warn|Error). Phase C runtime-strict flip
deferred. T22/T24 deferred. Auto-merged AddressSpaceApplier.cs + DriverHostActor.cs
with R2-04/R2-10; verified OpcUaServer.Tests 286/286 + Runtime.Tests 396/396.
Build clean.
2026-07-13 11:29:32 -04:00
Joseph Doherty b2a56ebf3b fix(driver-modbus): probe parses the factory DTO shape — timeoutMs no longer silently dropped (R2-11, 05/CONV-2) 2026-07-13 11:07:44 -04:00
Joseph Doherty 24435efa8b fix(driver-focas): equipment tags run the capability-matrix pre-flight authored tags get (R2-11, 05/UNDER-6) 2026-07-13 11:05:02 -04:00
Joseph Doherty e294416087 fix(driver-focas): equipment tags forced read-only until PMC writes exist; shared readers + Inspect (R2-11, 05/UNDER-1) 2026-07-13 11:01:55 -04:00
Joseph Doherty 4f5bbd253c feat(driver-twincat): shared TagConfigJson readers, writable key, Inspect warnings (R2-11) 2026-07-13 11:00:31 -04:00
Joseph Doherty 6e2415bb4c feat(driver-ablegacy): shared TagConfigJson readers, writable key, Inspect warnings (R2-11) 2026-07-13 10:59:27 -04:00