The ignitionoee CR capture (6d2aec40: 7 h read-only sample of 34 production
controls on the Java LSV2 driver) and the 2026-11-11 iTNC 530 run did not
change the driver's code: ProgramState 0 = cutting (11,865 of 11,869 motion
pairs), 7 = idle; TNC 426/430 BadNotSupported; overrides BadUserAccessDenied
under INSPECT; capabilities Unknown until first poll; alarm classes 1/7/8 seen,
class 5 not. Owner accepted the driver on that basis; remaining limits stay
documented in Heidenhain.md §Hardware-gated.
No public source exists for DNC_ERROR_CLASS / DNC_ERROR_GROUP or their numbers
(the table was written from memory). The iTNC 530 Technical Manual's PLC error
table documents the same class and group NAMES without codes; three real
iTNC 530 records corroborate 7/4, 7/3 and 1/3. DNC and LSV2 numberings are
known to differ (ProgramStatus vs R_RI 26), so the numbers stay unproven.
Docs/comments only; no behaviour change.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
Compared every R_RI decoder we use (22-28, 30-34, 51) byte-for-byte with pyLSV2 (MIT,
97a3d691) and ran the captured iTNC 530 replies through pyLSV2 itself: no decode
disagreement, so no published value changes.
- Additive read-only String leaves Status/ExecutionStateName, Status/ProgramStateName and
Tool/AxisName (pyLSV2 ExecState / PgmState / decode_tool_info names; out-of-table code =
"Unknown"). They ride the raw leaf's feature, so no extra wire read; raw Int32 leaves unchanged.
- Refusals: 52/72 -> BadOutOfRange, 58 -> BadTimeout, 56 -> BadInvalidState, 57 (outside the
alarm walk) -> BadNoData. IsStable and the 57-only alarm-walk end are unchanged.
Lsv2RefusalCodes names every code (pyLSV2 LSV2StatusCode) in exception/log/probe text.
- Timers 30-34 documented as uint32be seconds (lifetime counters) per pyLSV2, hardware-unproven;
TimersEnabled stays false. Axis/tool units: none on the wire, none assumed.
- Lsv2ReadOnlyPolicy untouched (pinned by a test); R_RI 20/21 left out.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
- PLC bit areas (MARKER/INPUT/OUTPUT/COUNTER/TIMER) accept 00/01/FF: real iTNC 530s
return FF for the same operands over R_DP, and pyLSV2 decodes them as non-zero = true.
02..FE stay BadDecodingError.
- New PLC:INPUT_DWORD / PLC:OUTPUT_DWORD areas (pyLSV2 MemoryType 13/12): signed
int32le, element index x 4 over the input/output-word byte pools.
- R_PR offsets agree with pyLSV2. Its count units (BYTE x2, WORD/IW as word counts)
conflict with the captured controls, so we keep the captures and pin them in a test.
- Docs: pyLSV2 correspondence table, native-operand mapping (no aliases), and why
raw R_MB is refused (pyLSV2 logs in as the write-capable PLCDEBUG role). That stays
an owner decision; Lsv2ReadOnlyPolicy is unchanged.
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
- HeidenhainControlFamily + HeidenhainControlFamilies.Classify (Contracts): one authority, ported from
pyLSV2 (MIT) dat_cls.py VersionInfo.control (strip spaces, case-insensitive prefix, ITNC530 first).
Families: ITnc530, Tnc (640/620/320/128), Tnc7, Lathe (CNC PILOT 640 / MANUALplus 620), MillPlus,
LegacyTnc (426/430, not a pyLSV2 class), Unknown.
- New additive read-only leaf Controller/Family (String, Identity feature, derived from the same R_VR
reply: no extra request). Lsv2Versions.Family is computed, so record equality and the #831
identity-change rediscovery signal are unchanged. Probe message + /hosts diagnostics (<host>.family).
- DATA gate now goes through SupportsDataPath(family) (pyLSV2 client.py read_data_path is iTNC-only):
non-iTNC and Unknown => Capabilities/DataLogin Unsupported, DATA login never sent. Replaces the
"model contains itnc" substring check (same result on the real iTNC530 controls).
- No per-family selector pre-gates: pyLSV2's TNC 640 observations (27/28/51/30-34 unknown telegram,
25/26 need DNC) are already handled by the reply-driven refusal/suppression path; tests pin it.
- Lsv2ReadOnlyPolicy, HeidenhainTagWritable and the no-IWritable rule are untouched.
- Simulator: per-family ControlProfiles (strings from the pyLSV2 README tables / protocol.rst), both
R_VR field counts, 124-byte R_PR; HeidenhainControlFamilyTests (classification, gates, decoding,
wire log inside the read-only set, refused selectors asked once).
- docs/drivers/Heidenhain.md: Control families matrix (iTNC 530 hardware-proven; the rest per pyLSV2,
hardware-unproven) + open questions (C_CC buffer size, encrypted passwords, R_RI 20/21).
Claude-Session: https://claude.ai/code/session_01GT67AD99zQQqpLCVm3p7xk
- RawTagRowRules: the ONE driver-dispatched authority on Tag-ROW rules (access level /
Tag.DataType). RawTreeService's save path, the CSV import's staged review grid
(RawTagCsvMapper) and the manual-entry grid all call it; no call site names a driver.
A ReadWrite or mistyped Heidenhain row is now invalid IN THE PREVIEW instead of only at Commit.
- Manual-entry grid + tag modal: when the driver dictates the data type for the row's
address (RawTagRowDefaults.DictatedDataType), the field is a locked read-only value instead
of a select that commit silently replaced; the grid runs the row rule client-side and no
longer rewrites the row at commit.
- Driver/device modals: the credential refusal is shown once (the modal's save-gate notice);
HeidenhainDriverFormModel / HeidenhainDeviceModel.Validate report only ranges / endpoint.
- docs/drivers/Heidenhain.md: #831 alarm conditions + rediscovery, #830 authoring behaviour.
Tests: HeidenhainAuthoringUxTests (CSV preview == ImportTagsAsync row-for-row, dictated type
is what the save path accepts, single credential surface, ALARM: seeding, CSV alarm rows,
AlarmMs round-trip); HeidenhainAuthoringTests updated for the single-notice rule.
docs/security.md gains the canonical table of per-driver namespaces, the five
enforcement seams, the out-of-scope cases (appsettings ${secret:}, Sql
connectionStringRef) and the migration steps for existing configs. Galaxy,
OpcUaClient, Heidenhain, Configuration and driver-specs docs, the Galaxy
options XML docs, the drivers rule file and the docker-dev compose comment
point at it. docker-dev's env:GALAXY_MXGW_API_KEY stays valid (allowed legacy
prefix), so no rig change is needed.
Co-Authored-By: Claude <noreply@anthropic.com>
- Review 1: RawTreeService Create/UpdateDriver and Create/UpdateDevice refuse a Heidenhain
config whose password fields are not blank / secret:heidenhain/... / env:OTOPCUA_HEIDENHAIN_...
(DriverConfigSaveGate over HeidenhainOptionsParser.DescribeCredentialProblems: top level,
Access, Devices[], case-insensitive keys; the value is never echoed), so a literal password
never reaches the draft DB. The driver and device modals show the reason and disable Save.
- Review 8: CreateTag/UpdateTag/ImportTags (tag modal, manual entry, CSV import, browse commit)
refuse a ReadWrite Heidenhain tag or a Tag.DataType that disagrees with what the driver
publishes (HeidenhainTagRules: catalog type, Float64 => Double, or the binding's dataType).
The tag modal and manual-entry grid fix the access level at Read and derive the data type from
the address (RawTagRowDefaults). New deploy gate HeidenhainTagDataTypeMismatch.
- docs/drivers/Heidenhain.md: credential namespace convention + why, the save-path and deploy
enforcement, optional-role credential behaviour, BadConfigurationError, backoff/ordering notes.
Tests: HeidenhainSavePathTests (service save path; red with the gates disabled) and new
DraftValidatorHeidenhainTests cases.