A legitimate consumer opening several keyed sessions at once from one key
(e.g. a ScadaBridge site node behind one NAT IP on a None endpoint) must
never see BadUserAccessDenied for parallelism. BeginAsync now hands out at
most MaxFailedAttempts - recordedFailures verification slots per key;
further activations queue FIFO and are woken as slots free. A waiter is
refused only when the key locks out (never reaching the authenticator) or,
uncounted, after OpcUa:CredentialLockout:SlotWaitSeconds (default 10,
BadTimeout). Cancelled waiters are dequeued; pruning accounts for waiters.
The security property is unchanged: no more than MaxFailedAttempts
unverified guesses in progress-or-failed per window.
1. Orphaned subscriptions (session closed without deleting subs) have Session == null, so the public
MonitoredNode2.InvalidatePermissionCacheForSession never reached their items: a cached allow survived a
deploy, the moved alarm's events were queued and delivered on TransferSubscriptions. Each notifier's
cache is now cleared whole through the SDK's private MonitoredNode2.InvalidatePermissionCaches
(reflection, guard-tested; fallback = per-session drop + Remove/Add of session-less items).
2. The verdict is decided on the condition LIVE under the event's NodeId, not the event's own instance:
the SDK key has no instance identity, so a replaced instance's late event cached a deny its successor
inherited until the next invalidation.
3. Invalidation is skipped while enforcement is off (forced across an on/off authorizer transition) and is
one O(cache) clear per node instead of a whole-cache scan per item.
4. TagReferencingEquipment carries alarm-bearing raw tags only (TagConfigIntent.Alarm); the snapshot adopts
an OrdinalIgnoreCase set instead of copying it again.
Tests (each fails with its fix reverted): FolderEventVerdictInvalidationTests (orphan + deploy + transfer;
replaced instance's late event; ACL-off skip; SDK private-method guard), DeploymentArtifactScopePathTests
(alarm-bearing projection).
Event items on an equipment / raw device folder were fed by the SDK's MonitoredNode2 fan-out with no ACL
decision, so after a deploy moved a scripted alarm (or dropped the reference projecting a native alarm into
an equipment) the OLD folder's subscribers kept receiving it - EventId included - until the rebuild landed,
indefinitely after a failed apply.
- OtOpcUaNodeManager re-implements INodeManager3 so ValidateEventRolePermissions (the SDK's per-event,
per-item hook; base not virtual) adds IsNotifierEventVisibleTo: live condition instance, notifier still a
legitimate notifier of it, and the #586/#808 Server-object rule (IsConditionVisibleTo over
ConditionVisibilityScopes).
- The SDK memoizes that verdict per (item, event type, SourceNode): InvalidateFolderEventVerdicts runs on the
authority/authorizer setters, RevalidateMonitoredItems (deploy + timer) and CompleteAddressSpaceApply.
- ConditionRefresh on direct items goes through RefreshDirectItems (base loop + the same decision).
- New generation field TagReferencingEquipment (RawPath -> EquipmentIds, from the artifact's
UnsTagReferences via AclScopePathResolver.ResolveTagRawPath): a native alarm's wired equipment folder only
counts (folder delivery AND Server-object scopes) while the current generation still references it.
- Secondary #808 edge: UNS variables wired UNS->Raw Organizes by AddReference are tracked and always placed
as reference variables (an Area named like its equipment's id no longer narrows them).
Tests: UnsFolderScopeWireTests (moved alarm on a folder item + ConditionRefresh + rebuild; area named like
equipment id), NativeAlarmFolderEventAclWireTests (dropped reference: folder + Server object + refresh +
restore), DeploymentArtifactScopePathTests (projection). Rig/event tests now supply tag references.
#820: SqlServer + QuestDB now serve Part 13 DurationGood / DurationBad from the
same Good / Bad region totals TimeWeightedAggregator already computes for
PercentGood / PercentBad — reported in milliseconds (OPC UA Duration, the SDK's
unit), Uncertain time in neither (Mantis 0006166), same BadNoData / status /
Partial rules. AggregateFamilies.Served grows 17 -> 19, so i=11201 and the
up-front refusal follow automatically; Gateway still refuses both (explicit
served set, unchanged). Client.Shared AggregateType / mapper / CLI gain both.
The #796 oracle answers DurationGood through the Good-only subclass as well.
QualityMix conformance asserts both directly (Q and QP, hand values, ms, and
= PercentGood x interval), replaces the "refused up front" test, and adds
Duration* to the forward/reverse/truncated oracle comparisons.
#821 (facts only, no decision): SdkAggregateParityTests pins an Uncertain-first
late-start interval (QP over [0,20), both directions) against ours (Part 13
Total 163.96, TimeAverage 10.93), the frozen 1.5.378.182 calculators (188.96,
9.448), SDK 2.0.1's stock calculators (188.96, 9.448) and a Good-first control
(all 163.96); LiveAggregateLateStartFactsTests pins the same through the booted
server's runtime AggregateManager (live AggregateFilter) incl. DurationGood
15000 / PercentGood 75 there vs 8000 / 40 in HistoryRead (#809). QualityMix
adds the reverse late-start variant (reverse TW pin + reverse oracle windows).
Co-Authored-By: Claude <noreply@anthropic.com>
OPC Foundation SDK 2.0.1's SessionManager lockout refused EVERY
activation (Anonymous included, before the token is read) from a client
with 5 failed identity validations in 60 s, for 5 minutes, keyed on cert
thumbprint else peer IP. Disable it (MaxFailedAuthenticationAttempts=0
on built and loaded configs) and enforce FailedCredentialLockout in the
identity-registry adapter instead: UserName activations only, keyed on
thumbprint+peer together, same 5/60s/300s defaults, configurable via
OpcUa:CredentialLockout.
Review of af5c9744:
1. UNS reference variables (s=Area/Line/Equip/Eff) of a moved or renamed
equipment stayed readable/writable under the OLD names' grants: they now
resolve as ReferenceVariable and are authorized at their split path only
while it equals their live equipment folder's placement (live chain ==
generation chain) + one name; otherwise denied (Read and Write).
2. TryPlaceScriptedCondition now also requires the owner folder's live chain
to match the generation (AuthorizeScriptedCondition gains ownerFolderChain),
so a moved equipment's alarm/children/commands follow its folder.
3. Identifiers containing NUL are denied before the decision cache, keeping
client ids disjoint from the NUL-prefixed resolved-scope keys (a client
could otherwise poison a real folder's cached verdict for its key shard).
4. An id no live node holds is Unknown: placed at [\0unknown] so only
Cluster / Namespace-uns grants decide it (a removed opaque id can no longer
split onto a same-named narrow grant; narrow grantees get no NodeDeleted for
removed UNS folders/vtags/conditions — documented); 4-segment
reference-shaped ids keep their split.
5. A wire test drives placements from DeploymentArtifact.ParseDataPlaneAuthority.
Baseline updates: #797 owner tests (unit + wire) and Sdk2RepeatedAlarmAuthority
now install folder scopes; Sdk2HistoryAuthority's UNS alias used the RAW path
as its UNS id (never minted in production) and now carries EqA/HistoryAlias.
Each new guard was falsified (reverting it fails its test).
UNS Area/Line/Equipment folders are minted under their opaque entity ids
(s=UA-/UL-/EQ-...), virtual tags under s=EQ-.../Name and scripted conditions
(+ #629 children) under s=<ScriptedAlarmId>[/...], while every UNS grant is
planted at a NAME path. DataPlaneAuthorizer split those ids, so with
Security:Acl:Enabled a narrow (Area/Line/Equipment) grant could not Browse,
Read, subscribe or HistoryRead them, and Server-object delivery never reached
it — so a narrow key never held the EventId Ack/Confirm/AddComment need.
- The generation carries UnsFolderScopes (folderId -> path + id chain), built
by DeploymentArtifact from the same AclScopePathResolver as the grants; ids
two entity kinds share are dropped; plumbed through IDataPlaneAuthoritySink.
- OtOpcUaNodeManager.ResolveUnsAclSubject reports live facts (folder id
ancestry / scripted owner binding); attached by the Authorizer setter.
- Evaluate places the subject against the CURRENT generation before the
decision cache, which now caches the walk keyed on the resolved scope.
Folders require live chain == generation chain (a moved equipment is denied
under old and new line until the rebuild). Owned nodes (vtags, conditions,
children) get owner path + a reserved segment, so Tag grants and their
Browse transit never expose them. Conditions share TryPlaceScriptedCondition
with the #797 command gate.
- Server-object visibility of a scripted condition is decided on the
condition alone, so a moved alarm cannot reach its old owner there.
Tests: UnsFolderScopeWireTests (opaque ids, end-to-end browse -> EventId ->
Acknowledge on an Equipment grant; sibling denied; Tag-only grant; moved alarm
and moved equipment stale windows). Rig tests now install folder scopes
explicitly (ServerEventRig.FolderScopes); the #797 recreate test deliberately
asserts the moved alarm is invisible to the Cluster observer in the window.
Review of 3d1b86b4: OpcUaPublishActor installs a new authority generation
before applying its address space, and an apply that throws keeps the old one.
A scripted alarm moved from equipment A to B therefore stayed commandable with
A's grant under B's generation (briefly before the rebuild, or indefinitely
after a failed apply).
The generation now carries ScriptedAlarmOwners (ScriptedAlarmId -> EquipmentId,
decoded by ParseDataPlaneAuthority from the artifact's ScriptedAlarms rows, the
same rows the composition materialises from). AuthorizeScriptedCondition denies
unless the node manager's live binding names the same owner as the generation:
a moved alarm is denied under the old owner's, the new owner's and a Cluster
grant until the address space re-binds it; an alarm the generation no longer
deploys is denied. Install/apply order unchanged.
Tests: window (a) generation moved / binding stale => both owners and Cluster
denied, then rebuild under the new owner => new owner allowed, old denied;
window (b) apply failed after install => denied across clock and further
generations, then a successful rebuild restores the new owner only; undeployed
alarm denied; artifact decode of the owner map.
Scripted condition NodeIds are opaque ScriptedAlarmIds, so splitting them as a
topology path could never match an Equipment grant: a narrow equipment grant was
denied while a Cluster grant passed.
- OtOpcUaNodeManager binds each LIVE scripted condition instance to the
EquipmentId it was materialised under (only when it hangs under that folder);
dropped on remove / drop-recreate / equipment-subtree removal / rebuild; a
same-id re-materialise under another equipment re-parents and re-binds.
- DataPlaneAuthoritySnapshot carries EquipmentScopePaths (EquipmentId ->
[uns, Area, Line, Equipment]) decoded from the artifact by the same
AclScopePathResolver call that plants Equipment grants.
- DataPlaneAuthorizer.AuthorizeScriptedCondition re-reads key, grant and
generation per call (uncached) and evaluates at the owner path; unbound,
replaced or unplaceable owners deny under every grant. No id-split or
realm-root fallback.
- Native conditions (RawPath) and the ACL-off role gate are unchanged.
NodeIds and AlarmCommand.AlarmId are unchanged.
Sdk2OpaqueScriptedScopeBaselineTests deliberately flipped: it pinned the denial
and now pins owner-grant allow / sibling deny / cluster allow. Follow-up #808
(folder ids + Server-object event visibility for narrow UNS grants).
- NodeManagerLockTimeBenchmark: wall-clock budget enforced only with OTOPCUA_BENCH=1; default run keeps the state-correctness asserts and logs timings.
- OpcUaClientDriverWire host-status: signal (semaphore) wait that only accepts a non-Running state observed after the server is disposed.
- AbCip PollLatencyComparison: retry once on a fixture connection reset; p95 criterion enforced only with AB_LAT_ENFORCE=1.
- ScriptRunGuardTests: orphan scripts held by a ctx.Released signal instead of a 250 ms wall-clock spin that could finish inside the 60 ms budget under load; stuck-orphan wall-clock rule disabled in the tests that pin the strike counting.
- DependencyMuxReplayTests: split the inside-grace positive control (1 h grace) from the release test (control asserted before unregister), removing the 200 ms grace race.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
Revises 963b0d66, which dropped a disabled VirtualTag from the runtime plan so a
bound client got BadNodeIdUnknown. Now the plan carries Enabled (part of value
equality): AddressSpaceComposer.Compose and DeploymentArtifact.BuildEquipmentVirtualTagPlans
keep the row with Enabled=false (byte-parity), the applier materialises the node as
normal, and VirtualTagHostActor spawns no VirtualTagActor for it but publishes
BadOutOfService (new OpcUaStatus constant) with a null value stamped at deploy, on
every apply. Enabled flips are node-irrelevant to the change classifier; enabled->disabled
stops the child, disabled->enabled resumes evaluation. Validator exemption and name
uniqueness unchanged. Scripted alarms keep their not-materialised convention.
Tests updated; new wire test DisabledVirtualTagWireTests. docs/VirtualTags.md updated.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
Behaviour-neutral hop: pin the SDK AggregateManager default to our
TreatUncertainAsBad=false (SDK .182 flipped it to true), parity guard now an
explicit deliberate-divergence assertion plus a booted-server check; adapt to
obsolete FindPredefinedNode(Type)/TraceConfiguration; Microsoft.Extensions.
Logging.Abstractions 10.0.7 -> 10.0.8 (SDK floor); stall wire test's late-flush
positive control is best-effort (.176 preserves publish queue ordering).
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
The 1500 ms pre-control and 500 ms trailing sleeps are gone. ConditionRefresh
completes server-side before SubscribeAlarmsAsync returns, so refresh events
queue ahead of the control Acknowledge; a trailing message-change barrier event
is projected and awaited (bounded 10 s poll) so any stray event must arrive
before it. The assertion is now the exact sequence [Acknowledge, Unspecified],
no weaker than before.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
Item 1 of #776 (the B2 over-the-wire ask): Client.CLI had no way to issue a
HistoryReadEvents. `historyread --events` now sends ReadEventDetails to an
event notifier and prints one line per event in select-clause order.
--fields picks the select clauses (default EventId, EventType, Time,
SourceName, Severity, Message, ConditionName (on ConditionType), SourceNode);
--of-type adds an OfType where-clause. --events is exclusive with --modified /
--aggregate, and --fields / --of-type require it.
Client.Shared gains IOpcUaClientService/ISessionAdapter.HistoryReadEventsAsync
(default-implemented as NotSupported for other implementations) backed by the
real session adapter through HistoryReadPaging, so continuation points are
followed up to --max and a Bad node status is surfaced, not printed as empty.
Tests: CLI tests over the fake service (default filter, --fields/--of-type
filter, option conflicts); an over-the-wire test drives the shared client's
event read against the in-process server — the default fields come back
non-null, OfType filters, an invalid where-clause is BadEventFilterInvalid.
The other #776 items are decisions and are left open.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
HistoryReadEvents projected only EventId / SourceName / Time / ReceiveTime /
Message / Severity: a select clause asking for EventType, ConditionName or
SourceNode (what most generic alarm viewers ask for) got nulls, and the
event filter's where-clause (an OfType) was ignored.
- HistoricalEvent gains optional EventTypeName, ConditionName and AlarmId.
SqlServer, QuestDB and Gateway event reads fill them from what their
alarm writers already store (AlarmTypeName / AlarmName / AlarmId; the
gateway event Type and its AlarmName / AlarmId properties).
- The node manager maps the type name to its Part 9 event type (unknown or
non-event => AlarmConditionType), projects ConditionName, and resolves
SourceNode to the materialised condition the alarm id names (the live
events' SourceNode), else null.
- The where-clause is evaluated per event with the SDK content filter
through an IFilterTarget (OfType via the type tree; other operators
against the projected fields), after the page's cursor is taken, so
paging is unchanged.
Tested in the node manager, over a real client session (the Client.CLI has
no `historyread --events` mode yet; filed as a follow-up), and by alarm
writer -> event read round trips on SqlServer and QuestDB.
Rebased from the unpushed remed/lane-H2 branch (originally authored 2026-10-22
in session_01Ub9hGmYLQvn9XETzw7CMsT) onto current master.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
Benchmark wall-clock budget 1 s -> 5 s (measured 5-60 ms; still catches O(N^2)). Host-status wait is already a TCS signal; its 30 s ceiling is raised to 120 s so a starved box cannot time out before the keep-alive reports the loss.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
The #733 miss budget (MissBurst / MissRefillPerSecond) was process-wide, because
the impersonation seam did not carry the client's address, so one noisy client
could drain it for everybody while the known-id set was unavailable.
- IOpcUaUserAuthenticator gains AuthenticateUserNameAsync(username, password,
IPEndPoint? remoteEndpoint, ct) (default: ignore it and delegate); the server
calls it. IApiKeyStore gains the matching FindAsync(..., IPAddress?, ...).
- The SDK (1.5.378) exposes no client address publicly. SecureChannelRemoteEndpoint
reads it from the TCP listener's private channel map by reflection (through the
protected TransportListeners, exposed by OtOpcUaSdkServer), keyed by the
session's secure channel id. Fail-soft: null => process-wide accounting only.
- BoundedApiKeyStore charges a miss to the client's own bucket (keyed by IP
address) and then to the process-wide one, which stays as the backstop. A
refusal by either takes from neither; a hit refunds both. New options
Security:ApiKeys:MissBurstPerEndpoint (10) / MissRefillPerSecondPerEndpoint (2),
0 disables; telemetry outcome endpoint_miss_budget. At most 4096 addresses are
tracked; idle buckets are pruned and an address beyond the cap is charged
process-wide only.
Tests: BoundedApiKeyStorePerEndpointTests (noisy client vs quiet one, process-wide
backstop, refund + refill, off switch, authenticator forwards the address) and
over the wire ApiKeyMissBudgetPerEndpointTests (activation hands the authenticator
the loopback endpoint; real authenticator + bounded store refuse a client's 3rd
and 4th unknown key without a store read). Each new behaviour test fails with its
fix mutated out. Host.Tests 224/0, OpcUaServer.Tests 1019/1 (the one failure is the
wall-clock NodeManagerLockTimeBenchmarkTests under suite load; passes alone).
Docs: security.md.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
AbLegacyDriver stamped LastSuccessfulRead (init, read, write), the read's sample
timestamps and host-state change times from raw DateTime.UtcNow; only the backoff
path read the injectable Clock. All of them now read Clock(), so
NativePcccBridgeStatusHealthTests drives a manual clock (init at T0, read at T1)
and asserts LastSuccessfulRead == T1 exactly instead of spin-waiting for the wall
clock to pass the init stamp (#767). Without the driver change the 6 tests fail
(init stamp is wall-clock, not T0).
Directory.Build.props sets TreatWarningsAsErrors for every project since #766, so
the 75 per-csproj copies (64 src + 11 tests) are removed and the props comment
says it is now the only place. tools/mem-probe keeps its explicit opt-out.
Release build: 0 warnings, 0 errors; a planted CS0168 still fails the build in a
src project and in a test project that used to carry its own copy.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
The native-ack path is fire-and-forget after the Part 9 Acknowledge returns, so
a Galaxy ack refused for lack of a credential (#749), or rejected by MXAccess,
left the client with Good and the condition showing Acknowledged while Galaxy
was never acked. Both options from the issue, layered:
1. Synchronous refusal for what the driver can decide without I/O. New optional
IAlarmAcknowledgePreflight (Core.Abstractions); GalaxyDriver refuses an
anonymous session when the driver has no AlarmAck fallback account.
DriverHostActor publishes a condition NodeId -> owning-driver snapshot into
NativeAlarmAckPreflightView (lock-free, volatile); the node manager's new
NativeAlarmAckPreflight seam, consulted after the authz and Primary gates,
returns BadUserAccessDenied with the reason - nothing routed, applied or
reported. A keyed session is not pre-checked (its identity lives in the
Secrets store, which must not be read under the SDK lock).
2. Revert for everything else. RouteAlarmAck carries the condition NodeId;
DriverInstanceActor replies AlarmAckFailed on a refusal, a backend failure,
a driver without an alarm source, or an ack dropped while connecting /
reconnecting. DriverHostActor re-projects the condition unacknowledged via
NativeAlarmProjector.TryRevertAcknowledge, but only while the local ack is
still pending - any driver transition projected since then wins. A disabled
or unspawned driver is not reverted (unchanged).
GatewayGalaxyAlarmAcknowledger now throws DriverOperationRefusedException on a
non-zero native hresult (wrong password, no ack permission) instead of only
warning, so that case reverts too; as a refusal it neither retries nor trips
the breaker.
Tests (each fails with its fix mutated out): projector revert/supersede,
DriverHostActor refused + failed ack -> unacked AlarmStateUpdate (successful
ack control), preflight view snapshot, node-manager preflight unit test,
over-the-wire ConditionMethodEventTests (BadUserAccessDenied, no route, no
event; positive control), Galaxy preflight + hresult refusal.
Docs: Galaxy.md, AlarmTracking.md, ScriptedAlarms.md, .claude/rules/alarms.md.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
HandlePublishError treated any anonymous BadNoSubscription (subscription id 0)
as loss of a tracked subscription whenever anything was tracked. A publish the
SDK queued while the session briefly held no subscription (the driver had just
deleted its last one) is answered BadNoSubscription and can be handled after the
replacement is registered, so a routine unsubscribe->resubscribe declared the new
subscription lost: Degraded health, a BadNoCommunication quality-only annotation
on every alarm condition and ConnectionLost (host re-initialise). That annotation
is the extra Unspecified event the #728 ConditionRefresh wire test saw.
- A BadNoSubscription that names a subscription id now counts only if the id is
tracked (same rule as BadSubscriptionIdInvalid).
- An anonymous BadNoSubscription within StaleNoSubscriptionGrace (5 s) of a
delete that left the driver tracking nothing is ignored (Debug log). The window
is stamped on removal and restarted when the delete completes; failed-subscribe
removes stamp it too; it resets with the session. A delete that leaves another
subscription tracked opens no window. A genuine loss inside the window is still
caught by the PublishingStopped heuristic; only the immediate ConnectionLost is
forgone.
- OpcUaClientStaleNoSubscriptionTests: stale error after alarm and data
resubscribe (fail without the fix), id-attributed stale error, plus genuine-loss
controls (after the grace, no recent delete, non-last delete, session release),
each mutation-checked.
- The ConditionRefresh wire test now records Kind, AlarmType, message, severity,
quality, restatement and timestamp of every post-resubscribe event on failure.
Wire test locally: 1/10 passing before (all 9 failures the 0x80310000
ConditionType quality-only annotation), 12/12 after.
Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
The Wave-2 lanes gave AbCip, AbLegacy and TwinCAT real whole-array write
encoders (review 07 U10/U9), but the capability table still listed all three
as scalar-only, so every array node materialised read-only and a client write
was BadNotWritable before it reached the driver.
Rows added, each listing only what WriteAsync encodes end to end:
- AbCip: SInt/USInt/Int/UInt/DInt/UDInt/Real/Dt/LInt/ULInt/LReal, declared
length, not a safetyTag. BOOL/STRING/Structure arrays stay read-only.
- AbLegacy: Int/AnalogInt on N/B/A, Long on L, Float on F (file-width match),
plain <file><n>:<word> address, <= 256 elements; not /bit, .sub, indirect,
S:/I:/O:, nor native PLC-5.
- TwinCAT: every codec element type, declared length; not a BOOL bit-in-word
path.
Elements convert in all three encoders, so the rows never key on an exact
node DataType (ScadaBridge int[] -> Int16 stays writable); they leave out
only node types whose elements never convert (DateTime/String over numeric,
Boolean on AbLegacy, STRING under DateTime on TwinCAT: culture-dependent).
Tests: driver-level parity for each driver (every element type x node type
plus shape cases, against the real write path), the AbLegacy parity tests
un-skipped, Core.Abstractions row tests, a composer test (three drivers
writable, refused shapes read-only), and the existing AbCip negative cases
moved to a BOOL array. Docs: Uns.md table, per-driver docs, data-plane rules.
Refs #737#738#739
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT