The tests probe a free port (bind 0, release) and start the SDK server later; under a
highly parallel run another test can take the port in between and the SDK fails with
'Failed to establish tcp listener sockets for Ipv4 and IPv6.'. OpcUaHostStart.StartAsync
builds a fresh host + server on a fresh port per attempt (up to 5) when the failure is a
bind failure; all 45 start sites in OpcUaServer.Tests, OpcUaServer.IntegrationTests and
Runtime.Tests use it. Per-attempt GUID ApplicationUris are hoisted out of the host factory
because a changed URI against a reused PKI store fails with 'Cannot access private key'.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
A degraded rebuild advances _lastApplied (deliberately), so re-deploying the
same revision diffed to an empty plan and reported a CLEAN outcome - the
#601 're-deploy re-applies' repair path sealed green over an address space
still known partial. The publish actor now remembers that the last advance
was degraded and, on an empty plan, re-ensures the whole composition
(idempotent, no rebuild), reporting clean only when that pass is clean.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
ApplyAck gains trailing Degraded/DegradedReason (defaulted, so an old node's
DPS JSON or gRPC ack decodes exactly as before). mesh_transport.proto adds
ApplyAckMessage.degraded = 6 / optional degraded_reason = 7. OpcUaPublishActor
replies RebuildCompleted(Degraded, Reason) on every handler path when the
RebuildAddressSpace carries ReportOutcome.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
A full RebuildAddressSpace recreated every native Part 9 condition inactive +
acknowledged, and when the alarm-tag set was unchanged (e.g. one
UnsTagReference added to an alarm-bearing raw tag) nothing re-told the new node
its state: the host does not re-subscribe for an unchanged set, and Galaxy /
OpcUaClient have no snapshot to replay anyway. Active alarms read normal until
their next device transition.
OtOpcUaNodeManager now captures each NATIVE condition's live state (from the
node, so a client-applied ack is kept) before the rebuild clears, restores it
when the same id is re-materialised native in the same apply, and reports ONE
condition event per restored off-normal condition at the new
IOpcUaAddressSpaceSink.CompleteAddressSpaceApply (after notifier wiring).
Unclaimed captures are discarded there, so a later re-add is fresh. Quality is
carried silently for normal conditions too (it is only re-annotated on a
connectivity edge). Scripted conditions are untouched (#487 re-asserts them).
OpcUaPublishActor calls CompleteAddressSpaceApply at the end of every apply.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
MAJOR-1: R4's exact element-type match refused ScadaBridge's CLR-list
writes (its element types are only Boolean/Int32/Float/Double/String/
DateTime) to every Int16/UInt16/Byte/UInt32/Int64/UInt64 array node and a
Double list to a Float array. EvaluateEquipmentWriteStructure now converts
a numeric array of another numeric element type element-wise, CHECKED, into
the node's element type and hands the converted array back through
OnEquipmentTagWrite's ref value, so the node stores and the driver receives
the node's own type. Any out-of-range, fractional-to-integer, NaN/Inf-to-
integer or Float-overflowing element refuses the whole write BadTypeMismatch
(nothing dispatched) - so the UInt32 -> Int32 bit reinterpretation stays
closed. Non-numeric mismatches stay refused. The wrong 'no client relies on
a looser rule' comment is corrected.
MINOR-1: the array-value-to-scalar-node refusal broke writes back to
browse-committed array tags (committed scalar, isArray never set) on
pass-through drivers. It now applies only when the owning driver's scalar
encoder cannot take an array (DriverArrayWriteSupport.
RefusesArrayValueOnScalarTag: Modbus, S7), carried RawTagPlan.
ScalarRefusesArrayValue / UnsReferenceVariable.BackingScalarRefusesArrayValue
-> EnsureVariable(refuseArrayOnScalar) -> a per-node set in the node
manager. OpcUaClient/Galaxy/others keep pre-#610 dispatch. Not on the
classifier whitelist (driver-type edit rebuilds); a mirror whose flag
changes is recreated, not updated in place.
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
C1 — a non-rebuild apply reporting failedNodes > 0 no longer advances _lastApplied.
Pre-delta-materialisation the full passes re-ensured every node on every apply, which
silently repaired any prior swallowed sink fault. The delta path removed that accidental
self-healing: a failed node sat inside _lastApplied, never appeared in a diff set again,
and EnsureVariable early-returns on the ones that landed — so it was lost until an
unrelated change forced a rebuild. The advance also moved to AFTER the materialise
passes, so a throwing pass leaves _lastApplied at the previous composition too. A
rebuild still advances even with failures (the ratchet is its resync path).
I2 — a UnsReferenceDelta whose identity is unchanged (same NodeId, EquipmentId and
BackingRawPath) is now applied in place via UpdateTagAttributes(Uns) instead of
remove+recreate, so the mirror's MonitoredItems survive an operator historizing or
reshaping the raw tag behind them. Remove+recreate stays for identity-changing deltas
(re-point, effective-name edit).
I3 — RemoveVariableNode severs the inverse half of every outgoing Organizes edge, the
variable-node counterpart of UnwireAlarmNotifiers. Rebuilds used to sweep these up;
surgical applies made rebuilds rare, so they accumulated on the raw node for the life of
the process.
I5 — added UNS reference variables are announced (their equipment folder is the parent,
already the Uns realm). Raw adds still are not; the gap comment now says so honestly
rather than calling it neutral and pre-existing.
I4 + M1 — corrected two comments that no longer described the code: the "re-point →
rebuild" claim in ApplyPureRemove, and the "N lock acquisitions" rationale for the delta
passes (Ensure* early-return on a dictionary probe before the lock).
Accumulated fast-follows from the Task 1-11 reviews. No behaviour change on the
value path.
- Strengthen OpcUaPublishActorBatchTests.Sink_throw_is_swallowed_and_logged. The
survival assertion alone did NOT prove the catch exists: Akka's default
supervision RESTARTS a throwing actor and the restart preserves the mailbox, so
the follow-up message landed either way and the test passed against a build with
no catch at all. It now asserts via EventFilter that the exception NEVER reaches
supervision (Expect(0) on the InvalidOperationException) and that the handler's
own Warning IS logged, keeping the survival assertion. Everything that must have
happened goes inside the Expect(0) action — it counts matches at the end of the
action, so an assertion left outside would race the actor and pass vacuously.
Verified falsifiable: deleting the catch turns the test red.
- MapKey(NodeId): the non-string identifier branch collapsed to a string.Empty key
silently. Such a key cannot match anything the manager stored, so the caller sees
an unexplained miss rather than an error. It now logs a Utils.LogWarning naming
the seam. Every current call site is provably string-only, so this should never
fire.
- The two WireAlarmNotifiers Utils.LogInfo sites interpolated the RealmKey struct,
rendering a raw struct dump. Interpolate .Id and .Realm as separate placeholders
so log-grep patterns stay consistent with the file's other sites.
- Stale comments: the _eventNotifierSources key is a RealmKey now, not a
namespace-qualified NodeId string; and three comments still named
DriverHostActor.ForwardToMux, which Task 8 replaced with ForwardBatchToMux.
#519 — a driver's OPC UA status code now reaches a client with its sub-code intact.
DriverInstanceActor projected the driver's uint onto a 3-state Good/Uncertain/Bad enum
and OtOpcUaNodeManager re-expanded Bad to a bare 0x80000000, so BadNoCommunication,
BadTypeMismatch and BadNotSupported were indistinguishable on the wire and every
driver's status constants (incl. the 16 #497 had just corrected) were diagnostic in
logs only. Resolved by option (b): the raw uint rides AttributeValuePublished ->
AttributeValueUpdate -> IOpcUaAddressSpaceSink.WriteValue, OpcUaQuality is deleted, and
severity classification is a helper (OpcUaStatus.IsGood/IsUncertain/IsBad).
The surface was wider than the issue costed (41 files, not "the sink and 3
implementations"): OpcUaQuality had non-driver producers with no uint to carry.
Each got its natural code — BadInternalError for a failed virtual-tag script,
BadNoCommunication for driver comms loss — and ScriptedAlarmHostActor's pair of
mutually-inverse uint<->enum mappers is deleted, having round-tripped a code the
engine already held. AddressSpaceApplier's removal writes deliberately keep the
generic Bad: not losing a code the driver had is this issue; inventing one for the
deploy path is a separate call.
Behaviour change: WriteAlarmQuality fires its Part 9 event on a status-code change
rather than a severity-bucket change. While the annotation was 3-state those were the
same predicate; now a move between two Bad reasons changes what a subscriber reads.
New SDK-free named constants live on Commons.OpcUa.OpcUaStatus, and
StatusCodeParityTests is widened to cover them — that guard is reflection-driven, so
it can only see a named constant, never an inline literal.
#517 — the symptom is real but the issue named the wrong path and its fix was unsafe.
ShutdownAsync cannot race: DriverInstanceActor calls it from PostStop, after the
mailbox drains. (Core/Hosting/DriverHost, the one class with a concurrent GetHealth,
has no production call site.) InitializeAsync can: it runs on a fire-and-forget
Task.Run, and MTConnectDriver writes Healthy then starts loops that can throw into a
catch which disposes the client before writing Faulted.
Moving the write earlier, as suggested, inverts the terminal state — teardown drains
in-flight loops that write health as they unwind, so a late loop could leave Healthy at
rest with every connection closed. The fix is a bracket (conservative before, terminal
after), applied to MTConnect's init-failure path only; shutdown keeps its single
trailing write, and the rule plus the reachability table are documented on
IDriver.ShutdownAsync.
CalculationDriver.GetHealth returned a hard-coded Healthy that consulted nothing —
Healthy before initialize, after shutdown and after dispose. Now derived from _running.
Its test, named Health_is_always_Connected, asserted the defect and is replaced.
Every new guard was falsified by breaking the production code and watching it go red.
The two sub-code tests each assert two different Bad codes, since a single-code
assertion could pass against a hard-coded constant under the old projection.
Pre-existing failures, verified unchanged on a stashed tree and not chased: 4 in
Driver.AbLegacy.IntegrationTests (slc500/micrologix/plc5 fixtures not up) and 3 in
Host.IntegrationTests.
Closes#517Closes#519
Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
tag gate, and fix three silently-broken OpcUaClient integration tests
Continues working through deferment.md's remaining items.
SKIPPED TESTS (13 -> 0 for this reason). The skip said "dark until Batch 4";
Batch 4 shipped as v3.0 and RETIRED the equipment-tag path rather than lighting
it, so every one of them was waiting on something that had already happened and
gone the other way. Resolved individually rather than in bulk:
- REVIVED onto the raw/UNS shape (6): four DriverHostActor primary-gate cases,
the cluster-scoping rebuild, and the real-SDK dual-namespace materialisation
E2E. The behaviour never went dark, only the v2 seeding did.
- FOLDED into a live parity test (3): DeploymentArtifactRawUnsParityTests
already compared RawTagPlan record-equal and RawTagPlan carries array /
historize / alarm intent, so widening its corpus by two tags covers what
three empty placeholder suites had been promising. Those suites are deleted.
- DELETED (4): subjects genuinely retired -- equipment-namespace EquipmentTags,
and both dot-joint {{equip}}.X token suites (that resolver was deleted in
Batch 3; the slash-joint form is covered by DeploymentArtifactEquipRefParityTests).
Falsified, not assumed: removing the seeded UnsTagReference turns two revived
primary-gate tests red; re-homing the SITE-A node to MAIN turns the scoping test
red. Widening a parity corpus also needed direct value assertions -- parity alone
cannot distinguish "both seams right" from "both seams blind".
Runtime.Tests skips 13->3, OpcUaServer.Tests 4->1; all remaining are deliberate
EquipmentDeviceBindingRetired tombstones.
G-7 (deploy-time TagConfig gate). MQTT shipped an Inspect() nobody ever called;
now wired. Replaced the hand-maintained list with a reflection guard, because the
existing test enumerates driver types by hand and so guards renames but can never
notice a gap. NOTE: the first version of that guard was hollow -- it discovered
candidates via GetReferencedAssemblies(), which is circular, since the compiler
elides a reference nothing in the IL uses. Removing MQTT from the map also removed
its Contracts assembly from the manifest, and the guard passed green with the bug
reintroduced. Rewritten to scan the output directory; re-falsified and it now
fails naming MqttTagDefinitionFactory. Residual recorded at the code: Sql,
MTConnect, Calculation and OpcUaClient have no Contracts-side Inspect at all, so
the deploy gate stays weaker than the AdminUI's authoring gate for them.
OPCUACLIENT INTEGRATION TESTS (3 of 4 failing, on master too). Not fixture rot:
the simulator was healthy and Client.CLI read the very same node Good. v3 made the
driver resolve every reference through its authored RawTags table, so a bare
"ns=3;s=StepUp" fails LOCALLY at the resolver with BadNodeIdInvalid and never
reaches the wire -- the tests were exercising the unresolved-reference guard.
Fixed by seeding OpcPlcProfile.RawTags in the deploy artifact's TagConfig shape
and addressing by RawPath. 4/4 pass.
DOCS. Applied the Phase7* -> AddressSpace* rename across the four live docs
(historical bannered files deliberately untouched), resolving the three that are
not renames to their real members. Found en route that the earlier banner pass
missed three files: VirtualTags.md, OpcUaServer.md and ScriptedAlarms.md all
still presented the test-scaffolding GenericDriverNodeManager as the production
dispatch path. All three now carry the correction.
Claude-Session: https://claude.ai/code/session_015p7wGqy3YpZNCpDzTpGMKo
#507 was filed as "injection inert in v3, re-migrate onto the raw subtree".
Reading it, the retained code is not revivable: it resolves equipment from
EquipmentNode.DriverInstanceId UNION EquipmentTags, and BOTH are structurally
empty in v3 (AddressSpaceComposer always constructs EquipmentNode with a null
DriverInstanceId; DeploymentArtifact hard-codes an empty EquipmentTags set).
Removing the guard would have changed a log line and injected nothing. So it
is deleted rather than fixed, and #507 closes as superseded by /raw
browse-commit.
Removed: HandleDiscoveredNodes, PartitionDiscoveredByDeviceHost,
ShouldWarnPartition, PlansRoutingEqual, ApplyDiscoveredPlansForDriver,
_discoveredByDriver, the redeploy re-inject tail, DiscoveredNodeMapper,
DiscoveredInjection, AddressSpaceApplier.MaterialiseDiscoveredNodes,
OpcUaPublishActor.MaterialiseDiscoveredNodes, and the Runtime-local copies of
CapturingAddressSpaceBuilder/DiscoveredNode.
The connect-time discovery loop goes too (StartDiscovery, RediscoverTick,
HandleRediscoverAsync, DiscoveredNodesReady, TriggerRediscovery). With
injection gone it had no consumer, and leaving it would either dead-letter or
keep browsing real devices up to ~15x per connect to drop the result.
ITagDiscovery itself stays — the /raw browse picker drives it through
Commons/Browsing/DiscoveryDriverBrowser, which never went through the actor,
so the picker is unaffected.
deferment.md §4.4 called the 18 DiscoveryInjectionDormantV3 tests "Real —
blocked on #507". They are not: they assert an equipment-rooted graft
(EquipmentRootNodeId == "EQ-1") that v3 cannot produce, so they could never
have unskipped as written. Deleted along with DiscoveredNodeMapperTests, the
CapturingAddressSpaceBuilder tests, and the MaterialiseDiscoveredNodes tests
in AddressSpaceApplierTests/OpcUaPublishActorTests. Runtime.Tests skipped:
31 -> 13.
IHostConnectivityProbe is deliberately NOT resolved here. GetHostStatuses()
has no production call site and nothing writes a DriverHostStatus row, but the
table was re-created in the v3 initial migration, so deleting on inference
would be wrong. Split to Gitea #521 with both options costed.
CLAUDE.md, docs/drivers/{Galaxy,TwinCAT,MTConnect}.md updated — they described
the seam as dead.
Build clean; Runtime.Tests 476 passed / 13 skipped; OpcUaServer.Tests 362
passed / 4 skipped.
The reported symptom was "Runtime.Tests occasionally reports Failed: 1" with no test
name. Instrumenting 30 full-assembly runs reproduced it at 13% (4 runs) and showed it
was never ONE flaky test: five failures across three distinct tests in that batch, and
five more distinct tests over the verification rounds that followed.
Two hypotheses were tested and DISPROVED by measurement before anything was changed:
- Cluster-formation timeout. Every test in this assembly forms a real single-node Akka
cluster over TCP in RuntimeActorTestBase's constructor and waits 5 s for MemberStatus.Up
— 219 formations per run. Instrumented: idle max 960 ms, under-load max 1470 ms, zero
timeouts. A 3.4x margin; not the cause.
- Ephemeral-port exhaustion from that bind churn. TIME_WAIT measured at ~0 throughout.
Not the cause.
FOUR GENUINE ORDERING/LOGIC DEFECTS (none is a timeout):
1. VirtualTagHostActorTests.ApplyVirtualTags_respawns_child_when_plan_changes_in_place
The test loops to accept RegisterInterest/UnregisterInterest in EITHER order — and
then asserts on mux.LastSender, which DEPENDS on that order. Under the [Register,
Unregister] interleaving LastSender is the DYING child and the assertion fails. Now
captures the sender of the Register message as it arrives. Fully deterministic; no
timing involved. (Swept the other four LastSender sites: all drain the Unregister
first, so their ordering is fixed. Only this one was unsafe.)
2. DriverHostActorWriteRoutingTests.Primary_routes_write_via_uns_nodeid_to_driver_by_rawpath
ApplyAck marks the end of the APPLY, not the point a write can succeed: the child is
still in Connecting, which deliberately fast-fails writes ("driver not connected"),
and the NodeId->driver reverse map has not been pushed. Now retries until accepted.
This does not weaken the assertion — every rejection branch replies WITHOUT reaching
the driver, so Writes.Count.ShouldBe(1) still means exactly what it did.
3. HistorianAdapterActorTests.Redundancy_snapshot_without_local_node_...
One 500 ms constant served both presence budgets (AwaitAssert) and absence windows
(ExpectNoMsg). Different quantities that happened to share a number, so the presence
budget could not be raised without slowing every absence check. Split into
AssertTimeout (5 s) and Settle (500 ms).
4. ContinuousHistorizationRecorderTests.Retry_after_writer_failure_eventually_acks
Waited on `outbox == 0`, which is ALSO true before the first append — so the poll
could win the race against the recorder and return having observed the INITIAL state,
after which the CallCount>=2 check outside the block failed against a recorder that
had not run. Both conditions are now polled together with the retry count as the
discriminator. (The preceding test in the same file documents this exact trap.)
THE PRESENCE-BUDGET CLASS:
After those four, three consecutive 30-run rounds each still failed once — on a
DIFFERENT test, in a DIFFERENT file, every time (OpcUaPublishActorApplyFailureTests 2 s,
OpcUaPublishActorRebuildTests 2 s, OpcUaPublishActorTests 500 ms). That is a
distribution, not a defect, and fixing it one test at a time was the wrong method.
RuntimeActorTestBase now carries a documented PresenceBudget (15 s) and 57 sub-3 s
AwaitAssert/AwaitCondition durations across four files route through it.
Why this is safe rather than sloppy: a presence budget is an upper bound before giving
up, not a wait — these helpers poll and return the instant the condition holds. Raising
one costs nothing on the happy path and CANNOT make a genuinely failing assertion pass;
it only changes how quickly a real breakage reports. Absence windows are the opposite
(the elapsed time IS the assertion) and were deliberately left untouched with their own
short, individually-calibrated literals.
ScriptedAlarmHostActorTests is a special case, diagnosed rather than merely raised: its
8 s budget was sized for message passing but actually waits on a REAL Roslyn compile
(ApplyScriptedAlarms -> ScriptedAlarmEngine.LoadAsync compiles every predicate). Cold
script compiles are the slowest and most variable thing in the assembly, so that class
gets 30 s with the reason recorded.
Verification: 30 consecutive full-assembly runs, 30 passed / 0 failed, against a 13%
baseline. Full solution builds; all 41 unit-test projects green.
NOT fixed here, filed as #501: DriverHostActorNativeAlarmAckRoutingTests:90 and :116 use
AwaitAssert for an ABSENCE assertion, so they return instantly and prove nothing. They
are excluded from the budget change on purpose — a bigger number does not fix them, and
rewriting them to settle-then-assert may legitimately turn them red.
A driver-only node has a null dbFactory but a wired applier; the old combined
guard routed it to the raw-sink fallback that wipes the address space and never
re-materialises. Split the guard so in-hand artifact bytes drive the real
diff-and-apply; a missing artifact abandons the rebuild (keep last-known-good,
#485) instead of wiping.
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
RedundancyStateActor derived the driver Primary from ClusterState.RoleLeader("driver").
Akka offers two different notions of a "first" member and they are not the same
one: role leader is the lowest-ADDRESSED Up member (host, then port), while
ClusterSingletonManager places singletons on the OLDEST — lowest up-number.
They agree on a freshly-formed cluster, which is why every existing test passed.
They diverge after any restart: the restarted node re-joins as the youngest while
keeping its address, so if it holds the lower address it becomes role leader while
the singletons stay put. The snapshot would then name a Primary that is not
hosting the work, and every Primary-gated surface follows it — inbound device
writes, native-alarm acks, the fleet-wide alerts emit, and the alarm-history
drain would all enable on the wrong node while the node actually running the
singletons stayed gated off.
BuildSnapshot now selects the oldest Up member carrying the driver role, matching
singleton placement. Leaving members are excluded: a node handing its singletons
over must not be named Primary.
NodeRedundancyState.IsRoleLeaderForDriver is renamed IsDriverPrimary, and
NodeHealthInputs.IsDriverRoleLeader likewise. Keeping the old names would have
left the wire contract asserting a derivation the code no longer uses — the same
drift that made this defect invisible.
Proven by a real two-node cluster rather than a mock. RedundancyPrimaryElectionTests
binds the first-joining node to the HIGHER port, so oldest and lowest-address name
different nodes, and includes a fixture assertion that the divergence actually
occurred — without it the real assertion could pass for the wrong reason. Positive
control: restoring the RoleLeader derivation turns exactly the two election tests
red while the fixture check stays green.
Runtime.Tests 440 passed, ControlPlane.Tests 82, Cluster.Tests 36.
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
A transient ConfigDb error while loading a deployment's artifact emptied the
served address space. LoadArtifact caught the exception, logged "rebuild
becomes no-op" and returned zero bytes; those parsed to an EMPTY composition,
which the planner diffed against the live one as a PureRemove and the applier
faithfully executed — 16 nodes gone, while the log claimed nothing happened.
An artifact we could not obtain is not an empty configuration. Nothing
legitimate produces a zero-length blob (an operator who really deletes
everything still deploys a JSON document with empty arrays), so "no bytes" can
only mean "no answer". HandleRebuild now abandons the rebuild on one, leaving
both the materialised nodes and _lastApplied intact so the retry diffs against
what is actually being served. The loader's own log line is now true.
The two cases are logged differently: warn when there is a live address space
being protected, debug when nothing has been deployed to this node yet.
Covered by a RED-first actor test (verified failing: the load error tore down
eq-2's subtree), plus a positive control proving a READABLE artifact that
genuinely drops an equipment still removes it — the guard suppresses teardown
only when the read failed.
Found on the LocalDb Phase 1 follow-up live gate, which induced it by flapping
SQL; that gate's log is the production evidence for the seam.
Closes#485
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
Part 9 ConditionType.Quality was never assigned; default(StatusCode)==Good
so every native + scripted condition reported Good unconditionally — a
comms-lost device still showed a healthy, inactive, Good condition (a
wrong-VALUE bug, distinct from the null-value #473/#475). Clients (and HMIs
bucketing on IsGood) could not tell "genuinely inactive" from "lost contact".
Layer 1 — make Quality a real, plumbed field:
- AlarmConditionSnapshot gains OpcUaQuality Quality (default Good).
- MaterialiseAlarmCondition sets it (native BadWaitingForInitialData, scripted Good).
- WriteAlarmCondition projects snapshot.Quality; the delta-gate gains a Quality
member so a quality-bucket change fires a Part 9 event.
Layer 2 — drive native quality from driver connectivity (a comms-lost driver
emits no alarm transitions, and an alarm-bearing raw tag has no value variable,
so quality can't come from either existing channel):
- DriverInstanceActor Tells parent ConnectivityChanged on Connected/Reconnecting.
- DriverHostActor fans it to every native condition the driver owns as
OpcUaPublishActor.AlarmQualityUpdate (Good on connect, Bad on disconnect).
- New dedicated IOpcUaAddressSpaceSink.WriteAlarmQuality sets ONLY Quality and
fires only on a bucket change — never touches Active/Acked/Retain (an active
alarm that loses comms stays active). Not a full-snapshot re-projection, so it
can't clobber severity/message and works for a never-fired condition.
Forwarded through DeferredAddressSpaceSink (F10b trap; auto-verified by the
reflection forwarding guard). Ungated by redundancy role; no /alerts row.
Scripted conditions stay Good; worst-of-input quality deferred to #478 (Layer 3).
Tests: node-level (materialise/project/no-clobber/unknown-node no-op),
NativeAlarmProjector, DriverInstanceActor connectivity emission, DriverHostActor
fan-out, OpcUaPublishActor routing, and the wire-level guard
(Condition_event_Quality_tracks_source_connectivity_on_the_wire) — RED-verified
against a simulated pre-fix always-Good server. Existing DriverInstanceActor
parent probes ignore the new ConnectivityChanged.
Docs: docs/AlarmTracking.md §"Condition source-data Quality (#477)";
design doc docs/plans/2026-07-17-alarm-condition-quality-477-design.md.
Materialize each native alarm ONCE at the raw tag (ConditionId = RawPath, Raw
realm); wire the single condition as an SDK event notifier of each referencing
equipment's UNS folder so one ReportEvent fans to every root without
re-reporting per root (which would break Server-object dedup + Part 9 ack
correlation).
- New sink method WireAlarmNotifiers(alarmNodeId, alarmRealm,
notifierFolderNodeIds, notifierFolderRealm) on IOpcUaAddressSpaceSink,
forwarded through DeferredAddressSpaceSink + SdkAddressSpaceSink +
NullOpcUaAddressSpaceSink (the forwarding-trap guard); auto-covered by the
DeferredSinkForwardingReflectionTests realm + forwarding guards + a
hand-written forward test.
- OtOpcUaNodeManager: the normative AddNotifier(isInverse) pair + idempotent
EnsureFolderIsEventNotifier per equipment folder; tracked per condition in
_alarmNotifierWiring. Teardown symmetry: RemoveNotifier(bidirectional:true) on
RebuildAddressSpace, RemoveAlarmConditionNode, and RemoveEquipmentSubtree so no
inverse-notifier entry leaks across redeploys.
- AddressSpaceApplier.MaterialiseRawSubtree wires notifiers for each native alarm
tag, resolving its ReferencingEquipmentPaths (Area/Line/Equipment) to the
EquipmentId folder NodeIds via BuildEquipmentIdByFolderPath.
- AlarmTransitionEvent gains ReferencingEquipmentPaths (empty default); /alerts
renders the referencing-equipment list as display metadata.
- Un-skipped + rewrote the native-alarm dark tests
(DriverHostActorNativeAlarmTests x6, DriverHostActorNativeAlarmAckRoutingTests
x1) for the v3 raw-condition model; new NodeManagerMultiNotifierAlarmTests
proves multi-notifier wiring + teardown symmetry (no leaked duplicates after a
re-trip) + applier wiring test.
Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
H1 (HIGH): write-routing key now (AddressSpaceRealm, bareId), not bare-only.
A raw s=<RawPath> and a UNS s=<Area/Line/Equip/Eff> can collide as bare
strings; the bare-only key let a colliding raw+UNS pair route to the WRONG
driver ref (last-writer-wins). The realm the node manager resolves (RealmOf)
is now threaded through IOpcUaNodeWriteGateway.WriteAsync -> RouteNodeWrite ->
_driverRefByNodeId keyed by (realm, bareId). New regression test:
Colliding_raw_and_uns_bare_ids_route_to_their_own_driver_by_realm.
M1 (MEDIUM): discovered-node injection made coherently DORMANT. HandleDiscoveredNodes
hard-short-circuits (single enforcement point; _discoveredByDriver never
populates so the re-inject tail is inert too), with a clear log pointing at the
/raw browse-commit flow. New pin: Discovered_nodes_are_ignored_dormant_in_v3;
the 16+2 v2 injection scenarios re-pointed to an accurate skip reason
(DiscoveryInjectionDormantV3).
M2 (MEDIUM): realm-qualified dual-node self-correction tests —
Failed_uns_write_reverts_uns_node_and_leaves_raw_node_untouched +
Raw_realm_revert_reverts_raw_node_only (the second fails if the realm is dropped).
L1: removed the = AddressSpaceRealm.Uns defaults from the consequential
node-manager mutation methods (WriteValue/WriteAlarmCondition/MaterialiseAlarmCondition/
EnsureFolder/EnsureVariable/UpdateFolderDisplayName/UpdateTagAttributes/
RaiseNodesAddedModelChange/Remove*/RevertOptimisticWriteIfNeeded) + the
AttributeValueUpdate/AlarmStateUpdate records, so the compiler forces explicit
realm; read-only accessors + internal builders retain their defaults.
L3: fixed the stale VirtualTagHostActor class comment (V3NodeIds.Uns, not the
retired EquipmentNodeIds.Variable).
Also: DeploymentArtifactRawUnsParityTests — Raw/UNS node-set byte-parity
round-trip between AddressSpaceComposer.Compose and DeploymentArtifact.ParseComposition.
Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
Wave B of Batch 4 — the runtime binding seam for the dual namespace.
Applier (both realms, explicit realm at every sink call site):
- MaterialiseRawSubtree: Raw containers as folders + Raw tags as variables
keyed by RawPath (native-alarm tag → single Part 9 condition at the RawPath),
all in AddressSpaceRealm.Raw; historian tagname = override else RawPath.
- MaterialiseUnsReferences: each UNS reference Variable under its equipment
folder (Uns realm) + an Organizes UNS->Raw edge; inherits writable/array/
historian tagname from the backing raw tag (both NodeIds -> one tagname).
- FeedHistorizedRefs / ProvisionHistorizedTags now source RAW tags (mux ref
stays single, keyed by RawPath); ApplyPureRemove tears down raw tags + UNS
refs in place (raw-container removal falls back to rebuild).
DriverHostActor (dual-NodeId, single-source fan-out):
- _nodeIdByDriverRef value gains a realm (NodeRealmRef); rebuilt from
RawTags UNION UnsReferenceVariables so one (DriverInstanceId, RawPath) fans
to the raw NodeId AND every referencing UNS NodeId with identical
value/quality/timestamp. Write inverse map keyed by the bare id; the
ns-qualified NodeId the write hook passes is normalised (BareNodeId) so a
write to either NodeId resolves the same driver ref (-> RawPath write).
- Native raw alarm condition routing is realm-tagged (Raw); AttributeValueUpdate
+ AlarmStateUpdate carry the realm through to the sink.
Retire EquipmentNodeIds -> V3NodeIds.Uns (applier/VirtualTagHostActor) and
RawPaths.Combine (DiscoveredNodeMapper, discovered nodes are Raw now).
DeploymentArtifact.ParseComposition emits the Raw + UNS subtrees byte-parity
with the composer (reconstruct entities -> AddressSpaceComposer.Compose).
Sink surface: removed the transitional `= AddressSpaceRealm.Uns` defaults from
IOpcUaAddressSpaceSink / ISurgicalAddressSpaceSink / SdkAddressSpaceSink /
DeferredAddressSpaceSink / NullOpcUaAddressSpaceSink — every call site is now
explicit (realm reordered before the trailing optionals on EnsureVariable +
MaterialiseAlarmCondition). Node-manager convenience methods keep their
defaults (they are not the interface impl; Sdk delegates explicitly).
Tests: rewrote DriverHostActorLiveValueTests (fan-out drift, 1:N) +
DriverHostActorWriteRoutingTests (dual-NodeId raw/uns write routing) to the v3
raw+uns model; new AddressSpaceApplierRawUnsTests; migrated the EquipmentTags
provisioning/feed tests to RawTags; swept EquipmentNodeIds test callers.
Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
Close the Wave-A M1 gap: the sink surface had no way to wire the mandated
cross-tree Organizes reference from each UNS reference Variable to its backing
Raw node, forcing WP3 to reopen the frozen surface. Add a dedicated
realm-qualified AddReference method instead.
- IOpcUaAddressSpaceSink.AddReference(sourceNodeId, sourceRealm, targetNodeId,
targetRealm, referenceType="Organizes"): realm-qualified both ends; idempotent;
a missing endpoint is a logged no-op (never throws) so a mid-rebuild race can't
fault a deploy. Base-interface capability (no surgical sniff, no transitional
default — WP3 wires it explicitly per UNS reference variable).
- SdkAddressSpaceSink forwards to the node manager; DeferredAddressSpaceSink
forwards unconditionally (like EnsureFolder); NullOpcUaAddressSpaceSink no-ops.
- OtOpcUaNodeManager.AddReference: resolve both nodes by full ns-qualified key
(variable/folder/condition via ResolveNodeState), guard both-exist, then wire
the edge bidirectionally (forward Organizes on source, inverse on target) with a
ReferenceExists idempotency guard + ClearChangeMasks on mutated sides. Reference
type resolved by ResolveReferenceType (Organizes default). Added internal
GetNodeReferences test/diagnostic accessor.
- Reflection guard: the exhaustive-forwarding test + the realm-discriminator guard
auto-cover AddReference (it has two AddressSpaceRealm params) — no edit needed.
- New SdkAddressSpaceSinkTests: Organizes UNS→Raw edge created bidirectionally +
idempotent; missing endpoint is a safe no-op.
- All 15 IOpcUaAddressSpaceSink test doubles gain the AddReference no-op so the
solution still builds.
Build: dotnet build ZB.MOM.WW.OtOpcUa.slnx = 0 errors.
Tests: Commons.Tests 310/310; OpcUaServer.Tests 337 passed / 4 pre-existing skips.
Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
Register both v3 namespaces (Raw first, UNS second) on OtOpcUaNodeManager and
thread an AddressSpaceRealm discriminator through every node-naming sink method
so a bare node id is resolved to the correct namespace by realm — never parsed
out of the id string.
- IOpcUaAddressSpaceSink / ISurgicalAddressSpaceSink: every node-naming method
gains `AddressSpaceRealm realm = AddressSpaceRealm.Uns` (transitional default so
un-migrated WP3 call sites still compile; WP3/Wave B makes them explicit and
removes the default). Null + SdkAddressSpaceSink impls updated; DeferredAddress-
SpaceSink forwards realm through every method (the forwarding trap).
- DeferredSinkForwardingReflectionTests: existing exhaustive-forwarding guard
auto-covers the new signatures; added an explicit guard that every node-naming
sink method carries an AddressSpaceRealm parameter (RebuildAddressSpace exempt).
- OtOpcUaNodeManager: register RawNamespaceUri + UnsNamespaceUri; realm->namespace
index via NamespaceIndexForRealm; all node maps (_variables/_folders/
_alarmConditions/_nativeAlarmNodeIds/_historizedTagnames/_eventNotifierSources)
re-keyed by the full ns-qualified NodeId string so Raw and UNS nodes sharing a
bare id stay distinct; _notifierFolders already NodeId-keyed. A historized UNS
reference node registers the SAME historian tagname as its backing raw node
(both NodeIds -> one tagname). Inbound-write hook routes the full ns-qualified
NodeId to the write gateway (realm-aware) and reverts by bare id + realm.
HistoryRead seams resolve via NodeId directly. DefaultNamespaceUri kept as a
transitional alias to UnsNamespaceUri for the SubscriptionSurvivalTests.
- Test doubles across Commons.Tests / OpcUaServer.Tests / Runtime.Tests updated to
the new interface signatures; SdkAddressSpaceSinkTests asserts the UNS namespace
index for default-realm nodes.
Build: dotnet build ZB.MOM.WW.OtOpcUa.slnx = 0 errors.
Tests: Commons.Tests 310/310; OpcUaServer.Tests 335 passed / 4 pre-existing skips.
Claude-Session: https://claude.ai/code/session_01LVneM3eh1UtJxEisFXgmox
Fix TESTS only (production already green) so the four in-scope test projects
compile + pass under the v3 dark address space:
- Core.Abstractions.Tests: drop AllowedNamespaceKinds/NamespaceKindCompatibility
from DriverTypeMetadata; rewrite EquipmentTagRefResolver tests to the single-func
RawPath-lookup contract (no parseRef/transient cache).
- Core.Tests: rewrite EquipmentNodeWalkerTests to EquipmentNamespaceContent(Areas,
Lines,Equipment,VirtualTags?,ScriptedAlarms?) — folders + VirtualTags +
ScriptedAlarms only; raw-tag variables dark (skipped Batch-4 placeholder). Drop
retired Equipment.DriverInstanceId.
- Runtime.Tests: rewrite golden corpus + TagConfigCorpusParityTests to the v3
RawPath/RawTagEntry round-trip (byte + TagConfigIntent parity; EquipmentTags dark).
Salvage VirtualTag + ScriptedAlarm artifact parity to the new Compose signature.
Retire the equipment-tag-materialization parity files (Array/Historize/Alias) and
the equipment-device-binding DeviceHost parity to documented skipped placeholders.
Skip 34 dark equipment-tag routing/value/alarm/write/discovery actor tests with a
shared DarkAddressSpaceReasons constant. Re-key cluster-scoped tests to v3 UNS
line->area attribution.
- ControlPlane.Tests: ConfigComposer round-trips re-keyed to RawFolder/Device (no
Namespaces); tag-config gate resolves driver via Device; deploy-gate collision test
re-keyed to UnsEffectiveNameCollision; drop retired BadCrossClusterNamespaceBinding
case.
A rename-only deploy produced an IsEmpty plan that short-circuited before MaterialiseHierarchy,
leaving the OPC UA folder DisplayName stale. AddressSpacePlanner now diffs UnsAreas/UnsLines by
stable id into a RenamedFolders set (counted in IsEmpty); the applier refreshes the folder in
place via a new UpdateFolderDisplayName on ISurgicalAddressSpaceSink (forwarded through
DeferredAddressSpaceSink so it is NOT inert on driver hosts; falls back to rebuild when the sink
is non-surgical). DeploymentArtifact byte-parity untouched (rename rides the existing Name
round-trip). No EF migration, no serialized wire/proto contract change. +13 OpcUaServer tests, Runtime rebuild test.
The OPC UA address-space build pipeline was named after a v2-roadmap
milestone number rather than its domain. Rename the family to describe
what it does (build/diff/apply the OPC UA address space):
Phase7Composer -> AddressSpaceComposer
Phase7CompositionResult -> AddressSpaceComposition
Phase7Planner -> AddressSpacePlanner
Phase7Plan -> AddressSpacePlan
Phase7Applier -> AddressSpaceApplier
Phase7ApplyOutcome -> AddressSpaceApplyOutcome
The 9 Phase7*Tests suites follow suit; Phase7ScriptingEntitiesTests ->
ScriptingEntitiesTests (it tests the scripting migration, not the
pipeline). Log-message prefixes move to the new class names.
Pure mechanical rename, no behavioral change. EF migration classes/IDs
(AddPhase7ScriptingTables, ExtendComputeGenerationDiffWithPhase7) are
immutable and left untouched, as are historical design docs.
Build clean; OpcUaServer 261/261, Runtime 272/272, ScriptingEntities
12/12 green.
Resolves the 12 reported build errors (7 CS0535 sink fakes + 5 CLI CS1587).
Runtime.Tests green (74). NOTE: OpcUaServer.Tests still has pre-existing CS7036
errors from the in-progress Galaxy-tag workstream (Phase7Plan/Phase7CompositionResult
new required params) — separate, test-only, not addressed here.
Adds <summary>, <param>, <typeparam>, and <inheritdoc/> tags to public
members surfaced by commentchecker — resolves 5,847 of 5,869 issues
(99.6%) across three /fixdocs passes.