Commit Graph

46 Commits

Author SHA1 Message Date
Joseph Doherty f594b29a7a test: deterministic CI-flake fixes (FOCAS alarm resubscribe, Modbus dead-port connect, S7 array poll)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 21:37:51 -04:00
Joseph Doherty 55ae230fa4 ci(#606): Gitea-compatible trx upload + deterministic fixes for the CI-load test flakes
- v2-ci.yml: upload-artifact@v4 -> @v3 + continue-on-error (act_runner reports as GHES and
  v4 refuses GHES, failing every run); runner-capacity diagnostic step; AKKA_TEST_TIMEFACTOR=3
  on the test step.
- Runtime/ControlPlane harnesses: akka.test.timefactor from AKKA_TEST_TIMEFACTOR
  (TestTimeFactor), single-expect-default 15s; ControlPlane gains PresenceBudget.
- Leaked spinner threads: the infinite-loop timeout tests (Calculation, Host.IntegrationTests
  RoslynVirtualTagEvaluator, 3x Core.Scripting) pinned a core for the rest of the test process
  (abandoned, never stopped). Now a bounded 5 s wall-clock spin; outer compile-inclusive bound 30 s.
- Real test races fixed: ScriptedAlarmEngine push-during-drain (Inactive is also the start
  state + persist-before-update => wait for the Cleared save); DriverReconnectE2e (both nodes
  host the driver; Created[] is last-writer-wins and ForceReconnect is a no-op while
  Connecting); ControlPlaneStarterOrder (lost-race heal waited for a 60 s refresh tick).
- Fixed sleeps -> poll-for-condition: ReconnectSupervisor LastError, Modbus deadband steps
  (wait for observed reads), Modbus dispose hygiene precondition, FOCAS probe-loop log.
- Short presence budgets -> PresenceBudget in the Runtime/ControlPlane tests seen failing on
  Gitea; Calculation Settle 10 -> 30 s. No assertion removed, nothing skipped.
- infra/README.md §10 CI; stale TreatWarningsAsErrors comment in Directory.Build.props.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 19:44:31 -04:00
Joseph Doherty dabd8eb955 fix(address-space): exact element-type check for array writes + array-capability shape edges (#610 review R4)
MAJOR-1: the SDK skips TypeInfo.IsInstanceOfDataType on any node with an
OnWriteValue handler (every writable equipment node), and the node manager's
fail-fast treated numeric<->numeric as compatible, so a UInt32[] to a Galaxy
Int32 array matched MxValueEncoder's int[] arm by CLR covariance and was
written bit-reinterpreted with a Good result. EvaluateEquipmentWriteStructure
now matches an ARRAY write's element type exactly (Byte[]/ByteString the only
equivalence; Variant[]/object[] refused) -> BadTypeMismatch, nothing
dispatched. MxValueEncoder's int[]/long[] arms are exact-type guarded too, and
the Galaxy parity test's false "the SDK refuses" premise is corrected (the
UInt32/UInt64 exclusion is now the encoder's own answer). Scalar writes keep
numeric widening by decision: consumers write CLR-typed values (Double to a
Float node) and every driver's scalar encoder range-checks.

MINOR: Modbus row honours maxRegistersPerWrite (smallest of DriverConfig /
the tag's DeviceConfig, default 123) and FC15's 1968-coil ceiling, and
requires region + numeric address; Modbus/S7/Galaxy require isArray + integer
arrayLength >= 1 (Galaxy: an unbounded node would let a short write resize the
attribute); an array value to a scalar node is refused inline. Docs: Uns.md
array-write rules + upgrade note (ReadWrite array tags become client-writable
on first boot), Modbus.md, Galaxy.md.

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 08:07:36 -04:00
Joseph Doherty 18f8eb5d2f feat(address-space): server-side array writes gated per driver capability (#610)
Array nodes were forced read-only for every driver. A new single authority,
Core.Abstractions DriverArrayWriteSupport, says which (driver, element type)
pairs encode a whole-array write: Modbus (Coils / numeric HoldingRegisters),
S7 (Byte/Int16/UInt16/Int32/UInt32/Float32), OpcUaClient (pass-through) and
Galaxy (Boolean/Int32/Int64/Float/Double/String/DateTime). Everything else
stays read-only, so the server never advertises a write the driver refuses.

- Composer derives RawTagPlan.ArrayWritable + UnsReferenceVariable
  .BackingArrayWritable at compose time (both seams, byte-parity); the
  applier's one writability rule is Writable && (!IsArray || ArrayWritable)
  for materialise and surgical paths, raw and UNS alike.
- ArrayWritable is on the classifier's surgical raw-tag whitelist and
  mirrored on the UNS record (UnsReferenceBackingParityTests updated).
- Node manager refuses a wrong-length / non-array value on an array node
  (BadTypeMismatch) and any IndexRange write (BadWriteNotSupported) inline,
  before dispatch; WriteOperate/ACL gates and the revert are unchanged.
- Per-driver parity tests pin the table against the real Modbus write path,
  S7 EncodeArrayBlock and Galaxy MxValueEncoder (UInt32/UInt64 excluded:
  array covariance reinterprets their bits).
- Over-the-wire proof in OpcUaServer.IntegrationTests (ArrayWriteWireTests).
- ValueRank > 1 documented as out of scope by decision (docs/Uns.md).

Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 07:39:05 -04:00
Joseph Doherty 7aa7758864 build: scoped OTOPCUA0001 NoWarn in 13 test projects, error under src/, pin SDK via global.json (#595 #606)
Claude-Session: https://claude.ai/code/session_01Ef2ozxS7QPanGT8uoATbTe
2026-10-08 06:47:40 -04:00
Joseph Doherty 409a58b624 fix(modbus): lifecycle gate + non-vacuous reprobe regression test 2026-08-16 04:07:27 -04:00
Joseph Doherty c3970a2e5d fix(modbus): dispose the previous transport and probe loops on re-initialize 2026-08-15 21:37:28 -04:00
Joseph Doherty 5c61d0b133 fix(modbus): exception-safe batch wrapper; driver batch wiring consistency 2026-08-15 12:27:19 -04:00
Joseph Doherty cd4ce305a2 fix(modbus): batch event honors deadband — raise from the driver-filtered buffer 2026-08-15 12:17:54 -04:00
Joseph Doherty ba55a5b48e feat(drivers): Modbus + S7 implement IBatchSubscribable via PollGroupEngine batch callback 2026-08-15 12:14:43 -04:00
Joseph Doherty f5475868f7 fix(inspect): trim before the framing check; stop advisories swallowing the backstop (#556); pin the MQTT payloadFormat mode contract (#557 item 2)
#556 item 1 — leading whitespace defeated every Inspect's pre-filter. Seven
factories (Modbus/S7/AbCip/AbLegacy/TwinCAT/FOCAS/Mqtt) tested
`reference[0] != '{'`, so a padded blob returned EMPTY and a tag the driver
refuses deployed clean. The check now trims first, matching the idiom
Sql/Calculation/MTConnect/OpcUaClient already used. The raw reference is still
what is handed to the mapper — the driver reads the stored blob, not a trimmed
copy — so the gate keeps mirroring the runtime rather than becoming lenient.
Both directions are pinned: a padded blob the mapper accepts still draws
nothing, and one that is not object-framed AFTER trimming still draws nothing
(it is not an equipment-tag TagConfig at all).

Six of the seven mappers hand the blob to a whitespace-tolerant
JsonDocument.Parse, so their verdict is unchanged by padding. MQTT is the
exception: both its readers carry the same framing gate, so a padded blob is
genuinely refused — which is why the untrimmed pre-filter was a real defect
there and not a cosmetic mismatch.

#556 item 2 — FOCAS and MQTT appended advisories unconditionally and then gated
the catch-all rejection message on `warnings.Count == 0`, so an advisory (which
fires on ACCEPTED blobs too, and says nothing about a refusal) silently
swallowed the only message naming a refusal nothing else can. The two classes
now accumulate in SEPARATE lists and the backstop gates on the rejection count
alone — structural, not string matching. MQTT's swallow was reachable in
production (a padded blob its readers refuse while every describe branch finds
the parsed document well-formed); FOCAS's backstop is currently unreachable by
audit, so its guard is protective.

#557 item 2 — decided and pinned: KEEP the union verdict. Evidence:
FromSparkplugTagConfig hard-codes PayloadFormat=Json and never consults the key;
only MqttSubscriptionManager (the Plain ingest path) decodes by it; and
MqttTagConfigModel.ToJson deliberately omits the key entirely in Sparkplug mode
(#513). So a Sparkplug driver genuinely serves the tag and rejecting it would be
stricter than the runtime. The cost — served behaviour depends on the driver's
MqttMode, which no tag row records — is paid by an ADVISORY naming the key and
the mode dependency, not by changing the verdict, so both gates keep agreeing.
The same invalid value on a blob the union REFUSES stays a rejection; the class
is decided by the accept gate, never by the key.

Falsified: reverting Modbus's trim reddens the padded-rejection theory;
neutering MQTT's backstop guard to the pre-#556 shape reddens the
advisory-plus-unnameable-rejection test; disabling the #557 advisory reddens the
contract pin; and for FOCAS, removing a describe branch alone stays green (the
backstop covers it) while additionally neutering the guard goes red.
2026-08-10 03:07:18 -04:00
Joseph Doherty 05b424788f fix(tagconfig): close the four #551 residuals — accept-gate-first Inspect, three authoring rules, CSV/service gate, doc sweep
Gitea #551.

1. CSV import ran no driver-typed config gate. Its typed columns were always
   strictly parsed, but the free-form TagConfigJson column reached the database
   unread, so a CSV could author a tag the driver rejects — one that deploys
   green and reads BadNodeIdUnknown forever. RawTagCsvMapper.Parse now names the
   offending row in the staged review grid, and RawTreeService enforces the same
   gate on CreateTag/UpdateTag/ImportTags: a form cannot be the guarantee (the
   API and any future caller reach none of them, and this repo has no bUnit).
   A rejected import row is an ERROR — the batch inserts nothing and the row is
   named — never a skip.

   Note the brief's premise that manual entry rides ImportTagsAsync is wrong:
   RawManualTagEntryModal commits row-by-row via CreateTagAsync, which is why
   the gate had to land on all three write paths.

2/3. The seven pre-#549 Inspect methods ran a hand-list of DescribeInvalidEnum
   checks, so every rejection cause not on the list was invisible. They are now
   ACCEPT-GATE-FIRST (the MTConnect/Sql/OpcUaClient/Calculation shape): ask the
   driver's own reader for the verdict, then explain the refusal, with a
   catch-all so "the parse rejects but Inspect said nothing" is unreachable.
   That closes S7's absent dataType, AbCip members[], Modbus stringByteOrder and
   the type-dependent guards, plus causes the issue did not name (absent
   region/address/tagPath/symbolPath/topic, TwinCAT Structure, MQTT's Sparkplug
   tuple). FOCAS and MQTT keep advisories about ACCEPTED blobs, so they
   diagnose rather than return empty.

   Authoring half: ModbusTagConfigModel gains stringByteOrder;
   AbCipTagConfigModel asks the new AbCipTagDefinitionFactory.DescribeInvalidMember;
   S7TagConfigModel captures whether the SOURCE blob declared dataType and asks
   S7TagDefinitionFactory.DataTypeKey/DeclaresDataType. One authority per rule.

4. Doc sweep: the six factory Inspect summaries, EquipmentTagConfigInspector's
   class remarks and AdminOperationsActor's comment all claimed invalid enums are
   "silently defaulted by the lenient runtime" — false since R2-11 Phase C made
   the runtime reads strict. They describe rejections now.
2026-08-10 00:08:06 -04:00
Joseph Doherty d32d89c340 fix(drivers): stop silently discarding driver config edits (§8.3, #516)
Five drivers ignored the config handed to them on reinitialize, serving the
options their constructor captured — and the deployment sealed green anyway.
Fixed on both halves, as chosen.

Seam (load-bearing): DriverSpawnPlanner routes a changed DriverConfig to
ToStop + ToSpawn instead of an in-place delta, making the factory the single
parse authority. This REVERSES the deliberate decision documented at
DriverSpawnPlan.cs:49-50 ("a pure DriverConfig change stays an in-place delta
— no reconnect"). That reasoning was correct about the resilience pipeline and
wrong about the driver. The accepted price is a reconnect per config edit.

Per-driver, and this split was not anticipated:
- Re-parse in place — Modbus, AbLegacy, OpcUaClient. ParseOptions extracted
  from each factory, called from InitializeAsync behind a HasConfigBody guard
  so "{}" still keeps the constructor options.
- Respawn-only, deliberately NOT re-parsed — Sql and FOCAS. Each builds more
  than options from config (Sql's dialect + resolved connection string,
  FOCAS's client-factory backend, both injected at construction), so adopting
  new options alone would run a NEW tag set against an OLD connection. Half a
  re-parse is worse than none. SqlDriver's doc-comment asserted the opposite
  premise — "config parsing belongs to the factory, which builds a fresh
  instance" — which was false when written and is true only now.

Two green seals removed from ApplyChildDelta: it overwrote the cached Spec
synchronously BEFORE the child dequeued the message, so the host believed the
new config was live and the next reconcile computed no delta, sealing the
drift permanently; and it Tell'd with no Receive<ApplyResult> registered, so a
failed reinit — including Galaxy's deliberate NotSupportedException —
dead-lettered.

Exposed (not created) by the change: a factory throw is a CONFIG error, and
SpawnChild catches it and silently substitutes a stub. Only a brand-new driver
could reach that before; an ordinary config edit can now. Raised Warning ->
Error with an actionable message. It still does not fail the deployment —
doing so would let one malformed driver block a fleet deploy, so that is a
follow-up rather than a drive-by.

Tests: every pre-existing reinit test in these suites passes "{}", the exact
input a guarded re-parser treats as "keep constructor options" — blind to this
defect by construction. New tests pass CHANGED json; the Modbus one was
verified falsifiable by deleting the re-parse (goes red). Two tests asserted
the old behaviour and were rewritten, including the positive control in
DriverHostActorUnreadableArtifactTests, whose observable moved from
UnsubscribeAsync to ShutdownAsync now that teardown happens by stopping the
child rather than emptying its desired set.

Remaining full-suite failures are pre-existing and environmental, verified
identical on the pre-change tree: Host.IntegrationTests (3) and
Driver.AbLegacy.IntegrationTests (4, docker fixture-gated).
2026-07-27 19:32:46 -04:00
Joseph Doherty ee12568cab refactor(modbus-rtu): distinct CrcMismatch/UnitMismatch desync reasons
v2-ci / build (pull_request) Successful in 4m1s
v2-ci / unit-tests (pull_request) Failing after 13m33s
The RTU framer overloaded DesyncReason.TruncatedFrame for three distinct
failures — a genuine short read, a CRC-16 validation failure, and a
CRC-valid reply from the wrong RS-485 slave. Split the latter two into
dedicated CrcMismatch / UnitMismatch enum members so a future .Reason
consumer (metrics, operator diagnostics) can tell a wiring/EMI CRC fault
apart from a mis-addressed multi-drop reply. Behaviour is unchanged — all
three still throw ModbusTransportDesyncException and tear the socket down.

Framing tests now assert the specific Reason on each path.

Follow-up #12 from the Modbus RTU-over-TCP plan.

Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-25 15:13:48 -04:00
Joseph Doherty fcc7ed698e harden(modbus-rtu): factory throws on unknown transport + document RTU FC-shape assumption
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 15:33:49 -04:00
Joseph Doherty 13bd9820b0 feat(modbus-rtu): route driver + probe transports through ModbusTransportFactory
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 14:12:12 -04:00
Joseph Doherty 1d90bf3611 feat(modbus-rtu): add ModbusTransportFactory switch on Transport mode
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 14:08:10 -04:00
Joseph Doherty 20be5416b9 feat(modbus-rtu): bind Transport mode on options/DTO/factory (string-enum guard)
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 14:04:34 -04:00
Joseph Doherty 47e9cd56ef feat(modbus-rtu): add ModbusRtuOverTcpTransport (RTU framing over socket lifecycle)
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 13:56:19 -04:00
Joseph Doherty 2f38b5b285 refactor(modbus): extract ModbusSocketLifecycle from ModbusTcpTransport (behaviour-preserving)
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 13:47:18 -04:00
Joseph Doherty 20100c36ad feat(modbus-rtu): validate response unit + cover partial-read/truncation in ModbusRtuFraming
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 13:42:25 -04:00
Joseph Doherty eed6617784 feat(modbus-rtu): add ModbusRtuFraming (ADU build + FC-aware length-less deframe)
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 13:33:59 -04:00
Joseph Doherty 8d0f60ec51 feat(modbus-rtu): add ModbusCrc CRC-16/MODBUS helper + golden vectors
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 13:30:05 -04:00
Joseph Doherty e787aa572b feat(modbus-rtu): add ModbusTransportMode enum (Tcp | RtuOverTcp)
Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
2026-07-24 13:28:30 -04:00
Joseph Doherty aafb9d4929 v3(b1-modbus): RawPath identity seam — RawTagEntry-driven Modbus driver
Wave-B EXEMPLAR. Retire the pre-declared/blob-parse tag model; the driver now
builds its RawPath -> definition table from the artifact's RawTagEntry set via a
pure mapper.

- Contracts: rename ModbusEquipmentTagParser -> ModbusTagDefinitionFactory;
  TryParse(reference) -> FromTagConfig(tagConfig, rawPath) (def.Name = rawPath,
  no leading-brace heuristic); add inverse ToTagConfig(def) serializer; keep all
  strict-enum reads + guards; also read stringByteOrder/deadband/coalesceProhibited
  so a RawTagEntry round-trips the full authored def. Inspect() unchanged.
- Options: Tags(IReadOnlyList<ModbusTagDefinition>) -> RawTags(IReadOnlyList<RawTagEntry>).
- Driver: _tagsByName -> _tagsByRawPath (Ordinal); resolver byRawPath-only; build
  the table from RawTags at Initialize threading entry.WriteIdempotent onto each def;
  Discover/Teardown updated.
- Factory: remove ModbusTagDto/BuildTag/ValidateStringLength + ConfigDto.Tags; bind
  RawTags from driver-config JSON.
- CLI ModbusCommandBase.BuildOptions: serialise typed defs -> RawTagEntry via ToTagConfig.
- Tests: migrate Tags= -> RawTags via ModbusRawTags.Entries helper; parser tests ->
  FromTagConfig(rawPath); factory String-length/enum tests re-seated on the mapper seam.
- Propagated rename to ControlPlane EquipmentTagConfigInspector (outside Modbus projects).

Modbus.Tests 315/315, Addressing.Tests 161/161, Cli.Tests 72/72 green.
Docker-gated Driver.Modbus.IntegrationTests left untouched (won't compile against
the new API; expected).
2026-07-15 19:50:10 -04:00
Joseph Doherty e8db0a683f fix(drivers): flip runtime tag parsers to strict enum parsing (#457)
v2-ci / build (pull_request) Successful in 4m12s
v2-ci / unit-tests (pull_request) Failing after 10m15s
R2-11 Phase C. All six equipment-tag parsers (Modbus/S7/AbCip/AbLegacy/
TwinCAT/Focas) now read enum fields via the new TagConfigJson.TryReadEnumStrict:
absent -> fallback, valid -> parsed, present-but-invalid (typo) -> TryParse
returns false -> EquipmentTagRefResolver.TryResolve false -> driver surfaces
BadNodeIdUnknown, instead of the old lenient path that silently defaulted a
typo to a wrong-width Good.

Modbus flips all three enum fields (region/dataType/byteOrder); the other five
flip dataType. The deploy-time Deployment:TagConfigValidationMode=Error gate is
unchanged and remains the operator pre-flight.

Coverage:
- Six *EquipmentTagParserStrictnessTests inverted from Freeze_typo_* (lenient)
  to Typo_*_rejects_the_tag + Valid_*_still_parses.
- TagConfigJsonTests.TryReadEnumStrict_rejects_only_invalid matrix.
- Driver-level end-to-end proof:
  AbCipEquipmentTagTests.Driver_read_of_a_typod_dataType_ref_surfaces_BadNodeIdUnknown
  drives the real AbCipDriver.ReadAsync through resolve->status.

Golden parity corpus has no typo'd enums, so the flip is a no-op there.
Full solution builds clean; all six driver suites + core + parity + gate green.
2026-07-15 11:28:34 -04:00
Joseph Doherty 6ee74d26fc docs(r2-09): record execution deviations; clear CS8604 nullable warning in the 5 PollErrorHealthTests
v2-ci / build (pull_request) Successful in 3m32s
v2-ci / unit-tests (pull_request) Failing after 9m27s
2026-07-13 12:45:50 -04:00
Joseph Doherty e69d3b3b0f fix(modbus): equipment tags carry unitId; ResolveHost keys per-unit via the resolver (CONV-4) 2026-07-13 12:29:13 -04:00
Joseph Doherty 9213c037b0 fix(drivers): wire PollGroupEngine onError->health + 30s poll backoff (05/STAB-9) [modbus,abcip,ablegacy] 2026-07-13 11:57:25 -04:00
Joseph Doherty 141c143586 test(modbus): failing repro for STAB-3 timeout/framing stream desync 2026-07-13 11:35:20 -04:00
Joseph Doherty b2a56ebf3b fix(driver-modbus): probe parses the factory DTO shape — timeoutMs no longer silently dropped (R2-11, 05/CONV-2) 2026-07-13 11:07:44 -04:00
Joseph Doherty 64b9bba9e9 feat(driver-modbus): shared TagConfigJson readers, writable key, Inspect warnings (R2-11) 2026-07-13 10:55:41 -04:00
Joseph Doherty 6853a0430f review(Driver.Modbus): validate FC03 RMW response + correct write error mapping
Re-review at 7286d320. Modbus-013 (Low): bit RMW now routes the FC03 read through the
validated ReadRegisterBlockAsync (was raw-indexing readResp -> IndexOutOfRange on a truncated
PDU). Modbus-014 (Low): WriteAsync maps InvalidDataException to BadCommunicationError (was
BadInternalError), matching ReadAsync. + TDD.
2026-06-19 11:34:34 -04:00
Joseph Doherty 4b14feb373 fix(drivers): serialize driver-config enums as strings in AdminUI pages + probes
AdminUI driver-instance pages serialized enum config fields (S7 CpuType,
Modbus DataType/Region, AbCip PlcFamily, ...) as JSON *numbers* because each
page's _jsonOpts lacked a JsonStringEnumConverter. The driver factories,
however, deserialize into string-typed DTOs (+ lenient ParseEnum) and throw
when binding a JSON number to a string? — so an AdminUI-authored config
containing any enum field produced a blob the driver could not parse,
faulting the driver on deploy. Proven end-to-end for S7 and Modbus; latent
for AbCip/AbLegacy/TwinCAT/FOCAS/Galaxy/Historian. Only OpcUaClient was safe
(its factory + probe already carried the converter).

Add JsonStringEnumConverter to all 9 driver-instance pages' _jsonOpts and the
8 missing driver probes' _opts (factories unchanged — already string-via-
ParseEnum; strictly more permissive, also lets pages load hand-seeded
string-enum configs back into the form).

Also fix DriverProbeHandshakeE2eTests.AbCip_Green_AgainstSim to probe a real
sim tag (TestDINT) — the no-tags @raw_cpu_type fallback is rejected by the
ab_server sim with ErrorBadParam (a real ControlLogix returns ErrorNotFound,
which the probe treats as reachable; hardware-gated follow-up).

Tests: reflection guard over all driver pages' _jsonOpts (AdminUI.Tests);
factory round-trip + numeric-form-throws guards for S7 and Modbus.

Found by running the never-before-run FB-9/FB-10 live verifies.
2026-06-19 04:52:47 -04:00
Joseph Doherty 49ac1392a8 fix(modbus): gate array read on isArray:true; 1-element arrays (review C-1) 2026-06-16 22:12:18 -04:00
Joseph Doherty 8d3dc32148 feat(modbus): String + BitInRegister array decode + equipment-tag arrayLength
- DecodeRegisterArray: add String and BitInRegister cases replacing the
  default:throw; each element decoded by reusing DecodeRegister on its
  contiguous register slice → string[] / bool[]
- ModbusEquipmentTagParser.TryParse: read optional arrayLength key from
  TagConfig JSON and thread it into ModbusTagDefinition.ArrayCount
  (null when absent or zero, preserving scalar behaviour)
- ModbusArrayTests: 8 new tests covering the two decode cases and the
  equipment-tag parser/resolver path; 285/285 green
2026-06-16 21:51:55 -04:00
Joseph Doherty 9b909002be feat(probe): Modbus Test-Connect does a real FC03 handshake
Replace the bare TCP-connect probe in ModbusDriverProbe with a two-phase
check: TCP connect via ModbusTcpTransport (keeps the same SocketException /
timeout / generic error paths and messages), then a one-shot FC03 Read
Holding Registers (qty 1 @ addr 0). A normal response → Ok=true "Modbus
FC03 OK"; a Modbus exception PDU → Ok=true "Modbus FC03 OK (device
returned exception PDU)"; any other failure after TCP succeeds → Ok=false
"Reachable at host:port but Modbus FC03 handshake failed: …".

Add ModbusDriverProbeTests (6 tests) covering invalid JSON, missing
host/port, closed port, TCP-accept-then-close, canned MBAP happy path,
and Modbus exception PDU path. All 277 Modbus tests green.
2026-06-16 06:36:48 -04:00
Joseph Doherty bd8fee610b fix(modbus): surface Int64/UInt64 node DataType (Driver.Modbus-007)
Make MapDataType internal, split the combined Int64/UInt64 arm to return
DriverDataType.Int64 and DriverDataType.UInt64 respectively, and remove
the now-stale Driver.Modbus-007 caveat doc block and inline comment.
Add a Theory covering both cases; full suite 271/271 green.
2026-06-16 05:23:47 -04:00
Joseph Doherty 232c557985 feat(modbus): resolve equipment-tag refs (read + write) via EquipmentTagRefResolver 2026-06-13 11:18:00 -04:00
Joseph Doherty 57355405a6 chore(security): drop dead audit suppressions; patch OpenTelemetry + Tmds.DBus CVEs
All five suppressed advisories are now resolved at baseline/resolved versions,
so every NuGetAuditSuppress is removed repo-wide:
- System.Security.Cryptography.Xml (GHSA-37gx-xxp4-5rgx / GHSA-w3x6-4m5h-cxqf)
  -> fixed by the .NET 10 baseline (10.0.6)
- OPCFoundation Opc.Ua.Core (GHSA-h958-fxgg-g7w3) -> fixed at resolved 1.5.378.106

Two were still live and are now patched via direct security pins:
- OpenTelemetry.Api 1.9.0 -> 1.15.3 (GHSA-g94r-2vxg-569j) pinned in Cluster;
  Runtime/ControlPlane/AdminUI + tests inherit via project reference
- Tmds.DBus.Protocol 0.20.0 -> 0.21.3 (GHSA-xrw6-gwf8-vvr9) pinned in Client.UI

Also correct the Historian sidecar runtime comments (x86 -> x64, matching the
csproj PlatformTarget). Solution audit: 0 vulnerable packages; full build clean.
2026-06-12 09:03:42 -04:00
Joseph Doherty 64e3fbe035 docs: backfill XML documentation across 756 files
v2-ci / build (push) Failing after 1m43s
v2-ci / unit-tests (tests/Core/ZB.MOM.WW.OtOpcUa.Cluster.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.ControlPlane.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Runtime.Tests) (push) Has been skipped
v2-ci / unit-tests (tests/Server/ZB.MOM.WW.OtOpcUa.Security.Tests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.Host.IntegrationTests) (push) Has been skipped
v2-ci / integration (tests/Server/ZB.MOM.WW.OtOpcUa.OpcUaServer.IntegrationTests) (push) Has been skipped
Adds <summary>, <param>, <typeparam>, and <inheritdoc/> tags to public
members surfaced by commentchecker — resolves 5,847 of 5,869 issues
(99.6%) across three /fixdocs passes.
2026-05-28 08:10:17 -04:00
Joseph Doherty 2b811477d1 chore(build): introduce central package management for v2
Adds Directory.Packages.props (ManagePackageVersionsCentrally) and
Directory.Build.props (net10.0/nullable/implicit usings/LangVersion latest).
Strips Version attributes from every csproj PackageReference and consolidates
versions into the central file.

Side fixes (necessary to keep the build green on .NET SDK 10.0.105 on macOS):

- Microsoft.CodeAnalysis.CSharp{,.Workspaces}: 5.3.0 -> 5.0.0. The 5.3.0
  analyzer DLL references compiler 5.3.0.0 and the local SDK ships compiler
  5.0.0.0, producing CS9057 on every project that loaded the Analyzers
  output. Master itself was broken on this machine pre-change.
- Server + Server.Tests pin OPCFoundation.NetStandard.Opc.Ua.{Configuration,
  Client} to 1.5.374.126 via VersionOverride, matching Opc.Ua.Server's
  pin. Mixing 1.5.378.106 Opc.Ua.Core transitively with 1.5.374.126
  Opc.Ua.Server breaks CustomNodeManager2 override signatures
  (CS0115 on LoadPredefinedNodes/Browse/HistoryRead*) and CS7069 in
  the tests. The pin disappears when the legacy Server project is
  deleted in Task 56.
- Client.UI + Client.UI.Tests: NuGetAuditSuppress for
  GHSA-xrw6-gwf8-vvr9 (Tmds.DBus.Protocol 0.20.0 reaches both projects
  transitively from Avalonia.Desktop on Linux/macOS only).

Deviation from the plan: TreatWarningsAsErrors=true is NOT set in
Directory.Build.props because the pre-v2 Admin/Server test projects carry
~240 xUnit1051 analyzer warnings that would fail the build. New v2 projects
opt in via their own csproj; the global flag can return once the legacy
projects are deleted in Task 56.
2026-05-26 03:40:24 -04:00
Joseph Doherty a6ae4e22d1 fix(status-codes): correct BadDeviceFailure from 0x80550000 to 0x808B0000
Driver.Cli.Common-007 + Driver.Cli.Common-008 resolution.

Driver.Cli.Common-007 (High, Correctness):
  0x80550000 is the canonical OPC UA spec value for BadSecurityPolicyRejected,
  not BadDeviceFailure. The correct spec value for BadDeviceFailure is
  0x808B0000 (verified against OPC Foundation Opc.Ua.StatusCodes;
  corroborated locally by Driver.Galaxy.Runtime.StatusCodeMap and both
  Wonderware historian quality mappers which all hand-pin the correct
  value).

  The bug was duplicated across six driver modules:
    - FocasStatusMapper.BadDeviceFailure
    - AbCipStatusMapper.BadDeviceFailure
    - AbLegacyStatusMapper.BadDeviceFailure
    - TwinCATStatusMapper.BadDeviceFailure
    - ModbusDriver.StatusBadDeviceFailure
    - S7Driver.StatusBadDeviceFailure
  Plus the SnapshotFormatter shortlist that named 0x80550000 as
  BadDeviceFailure, and three downstream Modbus tests that asserted
  against the wrong value (so CI was blind).

  This commit fixes all six native-mapper constants, the formatter
  shortlist, and the three Modbus tests in one pass. Added a regression
  guard to FormatStatus_does_not_apply_pre_fix_wrong_names that pins
  0x80550000 never renders as BadDeviceFailure (mirroring the existing
  -001 wrong-name guards).

  Behavior change: OPC UA clients consuming the native drivers now see
  the canonical BadDeviceFailure (0x808B0000) on device-fault paths
  instead of the misnamed BadSecurityPolicyRejected (0x80550000). Wire-
  level status semantics now match operator-facing CLI labels.

Driver.Cli.Common-008 (Low, Testing):
  Deleted the redundant FormatStatus_names_native_driver_emitted_codes
  Theory — its five InlineData rows were already covered by the
  well-known Theory in the same commit (5a9c459), and used a weaker
  ShouldContain vs the well-known Theory's ShouldBe (exact match).

Verification:
  - Driver.Cli.Common.Tests: 43/43 pass (was 48 after the -008 deletion).
  - Driver.Modbus.Tests: 263/263 pass.
  - Driver.AbCip.Tests: 262/262.
  - Driver.AbLegacy.Tests: 157/157.
  - Driver.FOCAS.Tests: 178/178.
  - Driver.S7.Tests: 112/112.
  - Driver.TwinCAT.Tests: 131/131.
  Total: 1146 tests across the affected modules, all green.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-23 17:14:28 -04:00
Joseph Doherty d5322b0f9a fix(driver-modbus): resolve Low code-review findings (Driver.Modbus-003,007,008,009,010,011,012)
- Driver.Modbus-003: route every _health access through ReadHealth /
  WriteHealth helpers backed by Volatile.Read / Volatile.Write so a
  burst of concurrent ReadAsync callers always sees a complete snapshot.
- Driver.Modbus-007: promoted the Int64 / UInt64 → Int32 surfacing
  caveat to a full <remarks> block; rewrote DisableFC23's doc to flag it
  as reserved / no-op.
- Driver.Modbus-008: deleted stale duplicate doc, rewrote the
  prohibition-block summaries to credit the shipped re-probe loop, and
  removed the unused 'status' local in the ModbusException catch arm.
- Driver.Modbus-009: bind-time validation rejects StringLength < 1 for
  String tags; ModbusTcpTransport clamps keep-alive intervals to whole
  seconds (>=1).
- Driver.Modbus-010: documented WriteOnChangeOnly's cache-invalidation
  policy (reads-only) and the write-only-tag caveat.
- Driver.Modbus-011: collected the scattered instance fields into a
  single contiguous block at the top of ModbusDriver.
- Driver.Modbus-012: covered the previously-uncovered Reinitialize
  state-hygiene, malformed/truncated/empty-bitmap response, and
  DisposeAsync teardown paths.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-23 08:17:51 -04:00
Joseph Doherty 532b961cf2 fix(driver-modbus): resolve High code-review finding (Driver.Modbus-001)
_lastPublishedByRef was a plain Dictionary<string, object> mutated inside
ShouldPublish, which runs on the PollGroupEngine onChange callback. The engine
runs one background Task per subscription, so a driver with two or more
subscriptions invokes ShouldPublish concurrently on separate threads. Concurrent
TryGetValue/indexer writes on a non-thread-safe Dictionary can corrupt internal
state, drop entries, or throw, crashing the poll loop.

Switch _lastPublishedByRef to ConcurrentDictionary<string, object>; its
TryGetValue and indexer-set operations are individually thread-safe, so the
deadband cache is now correct under concurrent multi-subscription publishing,
consistent with the lock-guarded sibling cache _lastWrittenByRef.

Add an xUnit + Shouldly regression test that runs 24 deadband-configured
single-tag subscriptions concurrently and asserts the poll loop survives without
faulting.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-22 06:59:39 -04:00
Joseph Doherty a25593a9c6 chore: organize solution into module folders (Core/Server/Drivers/Client/Tooling)
Group all 69 projects into category subfolders under src/ and tests/ so the
Rider Solution Explorer mirrors the module structure. Folders: Core, Server,
Drivers (with a nested Driver CLIs subfolder), Client, Tooling.

- Move every project folder on disk with git mv (history preserved as renames).
- Recompute relative paths in 57 .csproj files: cross-category ProjectReferences,
  the lib/ HintPath+None refs in Driver.Historian.Wonderware, and the external
  mxaccessgw refs in Driver.Galaxy and its test project.
- Rebuild ZB.MOM.WW.OtOpcUa.slnx with nested solution folders.
- Re-prefix project paths in functional scripts (e2e, compliance, smoke SQL,
  integration, install).

Build green (0 errors); unit tests pass. Docs left for a separate pass.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-05-17 01:55:28 -04:00