feat(modbus-rtu): add ModbusTransportFactory switch on Transport mode

Claude-Session: https://claude.ai/code/session_01GASWkNEi68FSCtvr6rLoEW
This commit is contained in:
Joseph Doherty
2026-07-24 14:08:10 -04:00
parent 20be5416b9
commit 1d90bf3611
2 changed files with 59 additions and 0 deletions
@@ -0,0 +1,37 @@
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus;
/// <summary>
/// Single mapping point from <see cref="ModbusDriverOptions"/> to the concrete
/// <see cref="IModbusTransport"/> its <see cref="ModbusDriverOptions.Transport"/> selects.
/// Consumed by both <see cref="ModbusDriver"/>'s default transport-factory closure and the
/// AdminUI Test-Connect probe, so the <see cref="ModbusTransportMode"/> switch lives in
/// exactly one place.
/// </summary>
public static class ModbusTransportFactory
{
/// <summary>
/// Builds the transport <paramref name="options"/>.<see cref="ModbusDriverOptions.Transport"/>
/// selects, threading every shared connection setting (Host/Port/Timeout/AutoReconnect/
/// KeepAlive/IdleDisconnectTimeout/Reconnect) through to whichever concrete transport is built.
/// </summary>
/// <param name="options">Driver configuration options.</param>
/// <returns>A <see cref="ModbusRtuOverTcpTransport"/> when <see cref="ModbusTransportMode.RtuOverTcp"/>
/// is selected; otherwise a <see cref="ModbusTcpTransport"/> (also the default/unrecognized fallback).</returns>
public static IModbusTransport Create(ModbusDriverOptions options)
{
ArgumentNullException.ThrowIfNull(options);
return options.Transport switch
{
ModbusTransportMode.RtuOverTcp => new ModbusRtuOverTcpTransport(
options.Host, options.Port, options.Timeout, options.AutoReconnect,
keepAlive: options.KeepAlive,
idleDisconnect: options.IdleDisconnectTimeout,
reconnect: options.Reconnect),
_ => new ModbusTcpTransport(
options.Host, options.Port, options.Timeout, options.AutoReconnect,
keepAlive: options.KeepAlive,
idleDisconnect: options.IdleDisconnectTimeout,
reconnect: options.Reconnect),
};
}
}
@@ -0,0 +1,22 @@
using Shouldly;
using Xunit;
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests;
public sealed class ModbusTransportFactoryTests
{
[Fact]
public void Tcp_mode_builds_tcp_transport()
=> ModbusTransportFactory.Create(new ModbusDriverOptions { Transport = ModbusTransportMode.Tcp })
.ShouldBeOfType<ModbusTcpTransport>();
[Fact]
public void RtuOverTcp_mode_builds_rtu_transport()
=> ModbusTransportFactory.Create(new ModbusDriverOptions { Transport = ModbusTransportMode.RtuOverTcp })
.ShouldBeOfType<ModbusRtuOverTcpTransport>();
[Fact]
public void Default_options_build_tcp_transport()
=> ModbusTransportFactory.Create(new ModbusDriverOptions())
.ShouldBeOfType<ModbusTcpTransport>();
}