9f7a4ac7692fa1eec7f43d2aa6f63164507a5416
261 Commits
| Author | SHA1 | Message | Date | |
|---|---|---|---|---|
|
|
9f7a4ac769 |
PR 3.3 — Wonderware sidecar pipe protocol + dispatcher
Sidecar now serves a length-prefixed, kind-tagged MessagePack pipe protocol mirroring Galaxy.Host's: 4-byte BE length + 1-byte MessageKind + body, 16 MiB cap. Hello handshake validates per-process shared secret + protocol major version + caller SID via ImpersonateNamedPipeClient before any work frame runs. Five contract pairs ship in this PR: ReadRawRequest ↔ ReadRawReply ReadProcessedRequest ↔ ReadProcessedReply ReadAtTimeRequest ↔ ReadAtTimeReply ReadEventsRequest ↔ ReadEventsReply WriteAlarmEventsRequest ↔ WriteAlarmEventsReply Timestamps cross the wire as DateTime ticks (long) to dodge MessagePack's DateTime kind/timezone quirks; both sides convert with DateTime(ticks, Utc). Sample values cross as MessagePack-serialized byte[] so the .NET 10 client (PR 3.4) deserializes per the tag's mx_data_type without the sidecar needing to know OPC UA types. HistorianFrameHandler dispatches by MessageKind to IHistorianDataSource (the PR 3.2 lifted interface) for reads, and to a new IAlarmEventWriter strategy for the alarm-event persistence path. Per-call exceptions surface as Success=false replies so a single bad request doesn't kill the connection. WriteAlarmEvents replies carry per-event success flags; the SQLite store-and-forward sink retries failed slots on the next drain tick. Program.cs spins the pipe server when OTOPCUA_HISTORIAN_ENABLED=true. Pipe- only mode (default false) preserves PR 3.1's smoke-test behaviour: the host still validates env vars and waits for Ctrl-C, but doesn't initialize the Wonderware SDK. Sidecar test project gains 8 round-trip tests (37 total now): every contract pair round-trips through FrameReader/FrameWriter via in-memory streams, the handler surfaces historian exceptions cleanly, WriteAlarmEvents per-event status flows through, and the no-writer-configured path returns a clean error reply. Added MessagePack 2.5.187 to the sidecar csproj. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
bc7ec746c5 |
PR 1+2.W — Wire HistoryRouter + AlarmConditionService into DI
Server-side singletons threaded through OpcUaApplicationHost → OtOpcUaServer → DriverNodeManager construction. New ctor parameters are last-position optional with null defaults so every existing test construction site (OpcUaServerIntegrationTests, AlarmSubscribeIntegrationTests, etc.) keeps working unchanged. Program.cs: AddSingleton<IHistoryRouter, HistoryRouter>(); AddSingleton<AlarmConditionService>(); The router stays empty after this PR. DriverNodeManager's internal LegacyDriverHistoryAdapter handles every driver that still implements IHistoryProvider; PR 3.W will register the Wonderware sidecar as a router source; PR 7.2 retires the legacy fallback entirely. 44 alarm + history + integration tests pass. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
9365beb966 |
PR 3.2 — Lift Wonderware Historian SDK code to sidecar
Move all historian implementation files from Driver.Galaxy.Host/Backend/Historian/ to Driver.Historian.Wonderware/Backend/. Sidecar now owns the aahClientManaged / aahClientCommon SDK references; Galaxy.Host project-references the sidecar so MxAccessGalaxyBackend keeps building until PR 7.2 retires Galaxy.Host entirely. 10 source files moved (preserving git history via git mv): IHistorianDataSource, HistorianDataSource, HistorianClusterEndpointPicker, HistorianClusterNodeState, HistorianConfiguration, HistorianEventDto, HistorianHealthSnapshot, HistorianQualityMapper, HistorianSample, IHistorianConnectionFactory. 2 historian tests moved alongside (HistorianClusterEndpointPickerTests, HistorianQualityMapperTests). Sidecar test project now hosts 29 tests (1 PR 3.1 smoke + 28 moved historian tests, all passing). Galaxy.Host's remaining 6 historian-flavored tests (HistorianWiringTests, HistoryReadAtTimeTests, HistoryReadEventsTests, HistoryReadProcessedTests) keep passing via the project reference — using directives updated to reach the new namespace. Sidecar deliberately speaks no Core.Abstractions — its surface is the legacy List<HistorianSample> shape; PR 3.4's .NET 10 client translates to the Core.Abstractions shapes added in PR 1.1. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
ef22a61c39 |
v2 mxgw migration — Phase 1+2+3.1 wiring (7 PRs)
Foundational PRs from lmx_mxgw_impl.md, all green. Bodies only — DI/wiring deferred to PR 1+2.W (combined wire-up) and PR 3.W. PR 1.1 — IHistorianDataSource lifted to Core.Abstractions/Historian/ Reuses existing DataValueSnapshot + HistoricalEvent shapes; sidecar (PR 3.4) translates byte-quality → uint StatusCode internally. PR 1.2 — IHistoryRouter + HistoryRouter on the server Longest-prefix-match resolution, case-insensitive, ObjectDisposed-guarded, swallow-on-shutdown disposal of misbehaving sources. PR 1.3 — DriverNodeManager.HistoryRead* dispatch through IHistoryRouter Per-tag resolution with LegacyDriverHistoryAdapter wrapping `_driver as IHistoryProvider` so existing tests + drivers keep working until PR 7.2 retires the fallback. PR 2.1 — AlarmConditionInfo extended with five sub-attribute refs InAlarmRef / PriorityRef / DescAttrNameRef / AckedRef / AckMsgWriteRef. Optional defaulted parameters preserve all existing 3-arg call sites. PR 2.2 — AlarmConditionService state machine in Server/Alarms/ Driver-agnostic port of GalaxyAlarmTracker. Sub-attribute refs come from AlarmConditionInfo, values arrive as DataValueSnapshot, ack writes route through IAlarmAcknowledger. State machine preserves Active/Acknowledged/ Inactive transitions, Acked-on-active reset, post-disposal silence. PR 2.3 — DriverNodeManager wires AlarmConditionService MarkAsAlarmCondition registers each alarm-bearing variable with the service; DriverWritableAcknowledger routes ack-message writes through the driver's IWritable + CapabilityInvoker. Service-raised transitions route via OnAlarmServiceTransition → matching ConditionSink. Legacy IAlarmSource path unchanged for null service. PR 3.1 — Driver.Historian.Wonderware shell project (net48 x86) Console host shell + smoke test; SDK references + code lift come in PR 3.2. Tests: 9 (PR 1.1) + 5 (PR 2.1) + 10 (PR 1.2) + 19 (PR 2.2) + 1 (PR 3.1) all pass. Existing AlarmSubscribeIntegrationTests + HistoryReadIntegrationTests unchanged. Plan + audit docs (lmx_backend.md, lmx_mxgw.md, lmx_mxgw_impl.md) included so parallel subagent worktrees can read them. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
012c42a846 |
Task #156 — TagsTab: per-tag advanced Modbus fields (Deadband, UnitId, CoalesceProhibited)
#155 wired the basic tag form (Name / Driver / Equipment / DataType / Access / WriteIdempotent + ModbusAddressEditor for the address). The per-tag knobs added across #141 / #142 / #143 still required operators to hand-edit TagConfig JSON. This commit exposes them through an "Advanced" expander. UI changes (TagsTab.razor): - Collapsible "▶ Advanced (Deadband / UnitId override / CoalesceProhibited)" button below the address editor, visible only when the selected driver is Modbus. Collapsed by default — basic form covers the typical edit workflow. - Three numeric / checkbox inputs with inline help text explaining each knob's purpose and when to use it. - _showAdvanced auto-opens on Edit when any of the advanced fields are present in the existing TagConfig — operators see immediately what's been configured. Save-side serialization: - New RefreshTagConfigJson serializes the address + advanced fields into a structured JSON object using a Dictionary<string, object?>. Fields with default / empty values are omitted to keep diffs in the existing draft-diff viewer minimal — a tag with only an address still produces `{"addressString":"40001:F"}` and not a full superset object with nulls. - OnAddressChanged + OnAdvancedChanged both delegate to RefreshTagConfigJson so any input change keeps TagConfig in sync. Read-side hydration: - New HydrateModbusFromTagConfig parses an existing TagConfig JSON and populates _modbusAddress + the three advanced fields. Falls back to empty defaults on malformed JSON. ResetAdvanced is called before hydration on every form open so leftover state from a previous edit doesn't leak. ResetAdvanced helper introduced + called from StartAdd so a fresh "New tag" form starts with everything cleared. Tests (1 new in TagServiceTests): - TagConfig_With_Advanced_Modbus_Fields_RoundTrips_Through_Factory — creates a tag whose TagConfig carries addressString + deadband + unitId + coalesceProhibited, persists via TagService, reloads, asserts every field survives. Then constructs a wrapping driver-config JSON and feeds it to ModbusDriverFactoryExtensions.CreateInstance — confirms the field NAMES the UI emits match what BuildTag's DTO consumes. If the UI's JSON shape ever drifts from the factory's expected DTO, this test catches it before users do. 119 + 1 = 120 Admin tests green. Solution build clean. |
||
|
|
ec57df1009 |
Task #155 — TagService + TagsTab CRUD UI for Modbus tags
Closes the remaining loop on user-visible Modbus tag editing. Pre-#155 tags arrived only via SQL seeding or runtime ITagDiscovery; the Admin UI had no interactive surface for creating / editing / deleting tag rows. Changes: - TagService.cs (Admin/Services/) — CRUD wrapper around OtOpcUaConfigDbContext.Tags. ListAsync supports optional driver / equipment filters; CreateAsync auto-derives TagId; UpdateAsync persists editable fields; DeleteAsync removes the row. Mirrors the EquipmentService shape. - TagsTab.razor (Components/Pages/Clusters/) — list + filter + add/edit/remove form. The address/config editor is conditional: when the selected DriverInstance is Modbus, ModbusAddressEditor (#145) renders with live-parse preview; otherwise a generic JSON textarea (matches the DriversTab pattern from #147). Save-side serializes the address-string into TagConfig as `{"addressString":"..."}` JSON. - ClusterDetail.razor — new "Tags" tab in the cluster-detail nav strip + the routing switch. - Program.cs — TagService registered as a scoped DI service. Drive-by fix: ModbusDriverFactoryExtensions.CreateInstance promoted from internal to public — Admin.Tests was using it via reflection-friendly internal access that broke under the #153 logger overload addition. Public is the right access modifier anyway since the Server-side bootstrapper calls it from a different assembly. Drive-by fix #2: ModbusDriverConfigDto was missing MaxReadGap (#143) — surfaced by the #147 round-trip test that flips MaxReadGap=12 in the view model and asserts it lands on the resolved options. Added the field + binding line. Confirms #143's DriverConfig JSON binding was incomplete since the original commit; no production deployment configured this knob through JSON until now so the gap stayed hidden. Tests (4 new TagServiceTests): - Create_And_List_Surfaces_The_Tag — CreateAsync auto-assigns TagId; list returns the row. - List_Filters_By_DriverInstance — driver-scoped filter works. - Update_Persists_Editable_Fields — Name / DataType / AccessLevel / TagConfig all persist through Update. - Delete_Removes_The_Row — basic delete verification. 113 + 4 (TagService) + 2 (DriversTab round-trip restored after compile fix) = 119 Admin tests green. Solution build clean. Caveat: bUnit-style render tests for TagsTab still aren't included — Admin.Tests doesn't have bUnit set up. The TagService logic is fully covered; the razor component's parser/save glue is exercised by hand at runtime for now. |
||
|
|
802366c2c6 |
Task #154 — driver-diagnostics RPC: HTTP endpoint + Admin client
Foundation for surfacing per-driver runtime state from the Server process to the Admin UI. #152 shipped GetAutoProhibitedRanges() as an in-process accessor; #154 makes it reachable across processes. Server side (HealthEndpointsHost): - New URL family: /diagnostics/drivers/{driverInstanceId}/{driverType}/{topic} - First wired topic: /diagnostics/drivers/{id}/modbus/auto-prohibited - Driver-agnostic at the URL level — future driver types add their own segments[3] cases (e.g. /diagnostics/drivers/{id}/s7/dropped-pdus). - 404 when the driver instance doesn't exist; 400 when the driver exists but isn't a Modbus driver (the per-type endpoint is wrong for this row). - Response shape is flat JSON (unitId / region / startAddress / endAddress / lastProbedUtc / bisectionPending) so consumers don't have to reference the Driver.Modbus assembly's ModbusAutoProhibition record. - Re-uses the existing HttpListener bound to localhost:4841 — same auth / reachability story as /healthz and /readyz. Admin side: - DriverDiagnosticsClient (Services/) — HttpClient wrapper that fetches the per-driver Modbus prohibition list. Returns null on 404/400 (driver missing or wrong type); throws on transport failures. - ModbusAutoProhibitionsResponse + ModbusAutoProhibitionRow flat DTOs — client doesn't take a dep on Driver.Modbus. - ModbusDiagnostics.razor at /modbus/diagnostics/{driverInstanceId} — table view with BISECTING (warning yellow) / ISOLATED (danger red) badges, relative timestamps (e.g. "5m ago"), Refresh button. Errors surface inline rather than swallowing. - HttpClient registration in Program.cs reads DriverDiagnostics:ServerBaseUrl from appsettings.json (default http://localhost:4841/ for same-host deployments). Tests (3 new in HealthEndpointsHostTests): - Diagnostics_ReturnsModbusAutoProhibitions_ForLiveDriver — registers a Modbus driver with a programmable transport that protects register 102, records the prohibition via a coalesced ReadAsync, hits the endpoint, asserts the returned JSON matches (unitId / region / start / end / pending). - Diagnostics_404_When_Driver_Not_Found - Diagnostics_400_When_Driver_Is_Wrong_Type Architecture note: the Admin-side bUnit-style component test isn't included because Admin.Tests doesn't have bUnit set up. The DriverDiagnosticsClient is unit-testable on its own with a mock HandlerStub if needed — left as a follow-up alongside the broader bUnit setup task. The diagnostic page is now reachable at /modbus/diagnostics/{driverId} from any Admin instance pointing at a Server endpoint URL. Future driver types (S7, AbCip) plug into the same channel by adding their own URL segments in HealthEndpointsHost.WriteDriverDiagnosticsAsync. |
||
|
|
8004394892 |
Task #153 — ModbusDriver: inject ILogger so prohibition events reach a sink
#152 left a hook for structured logging when an auto-prohibition first fires; this commit completes the wiring. Changes: - ModbusDriver constructor takes an optional ILogger<ModbusDriver> (defaults to NullLogger). Existing standalone callers stay compile-clean. - RecordAutoProhibition logs LogWarning on first-fire only (re-fires of the same range stay quiet via the existing isNew de-dupe). Format includes DriverInstanceId, UnitId, Region, Start, End, Span — log aggregators can filter / count by any field. - New LogProhibitionCleared helper called by both StraightReprobeAsync (when the re-probe succeeds on a single-register range) and BisectAndReprobeAsync (per-half clearing + a single combined line when both halves succeed). - ModbusDriverFactoryExtensions.Register accepts an optional ILoggerFactory. Captured at registration time and used in the factory closure to construct a per-driver logger. Server bootstrap code that already has an ILoggerFactory in DI threads it through with a single argument addition; old call sites (Register(registry)) keep working with a null logger. Tests (2 new ModbusLoggerInjectionTests): - First_Failure_Emits_Single_Warning_Subsequent_Refire_Stays_Quiet — pins the de-dupe behaviour. First scan logs one warning with the expected structured fields; second scan with the same prohibition stays silent. - Reprobe_Clearing_Prohibition_Emits_Information_Log — protected register unlocked between record and re-probe; re-probe success emits an info log containing "cleared". CapturingLogger test harness is purpose-built (xUnit doesn't ship a logger mock by default and adding Moq is overkill for two tests). 240 + 2 = 242 unit tests green. |
||
|
|
b8df230eb8 |
Task #152 — Modbus coalescing: surface auto-prohibitions through diagnostics
Auto-prohibited ranges (#148) were previously visible only through an internal AutoProhibitedRangeCount accessor used by tests. Production operators had no way to see what the planner had learned without pulling logs or inspecting driver state. Changes: - New public record `ModbusAutoProhibition(UnitId, Region, StartAddress, EndAddress, LastProbedUtc, BisectionPending)` — operator-facing snapshot shape. Lives in the addressing assembly's logical namespace alongside the other public types. - `ModbusDriver.GetAutoProhibitedRanges()` returns `IReadOnlyList<ModbusAutoProhibition>` — a copy of the live prohibition map. Lock-protected snapshot so consumers don't race with the re-probe loop. - RecordAutoProhibition tracks first-fire vs re-fire via the dictionary insert path, leaving a hook to add structured logging once an ILogger is plumbed through (currently elided to keep the constructor minimal for testability — a future change can wire ILogger and emit a single warning per first-fire). Tests (1 new, additive to the 6 in ModbusCoalescingAutoRecoveryTests): - GetAutoProhibitedRanges_Surfaces_Operator_Visible_Snapshot — confirms the snapshot shape: empty before any failure, populated with correct UnitId/Region/Start/End/BisectionPending after a failed coalesced read, LastProbedUtc within the recent past. Docs: - docs/v2/modbus-addressing.md — new "Coalescing auto-recovery" subsection consolidates the #148/#150/#151/#152 surface in one place. Documents the diagnostic accessor + flags the in-process consumption pattern (Server health endpoints today; Admin UI when an RPC channel exists). 239 + 1 = 240 unit tests green. Caveat: the Admin UI surfacing (table render, "clear all prohibitions" button) is intentionally NOT shipped here. Admin can't reach a live ModbusDriver instance without a driver-diagnostics RPC channel that doesn't exist yet — that's a larger architectural piece. For now the data is queryable in-process by the Server's health endpoints; once an RPC channel lands, Admin can wire the existing GetAutoProhibitedRanges into a Blazor table without further driver changes. |
||
|
|
f823c81c96 |
Task #150 — Modbus coalescing: bisection-style range narrowing
Pre-#150 a coalesced read failure recorded the FULL failed range as permanently prohibited. Healthy registers around the actual protected register stayed in per-tag mode forever (until ReinitializeAsync). The re-probe loop shipped in #151 retried the whole range as a single block, which would either succeed (clearing everything) or fail (changing nothing). Post-#150 the re-probe loop bisects multi-register prohibitions: - _autoProhibited refactored from Dictionary<key, DateTime> to Dictionary<key, ProhibitionState> where ProhibitionState carries LastProbedUtc + SplitPending. Multi-register prohibitions enter with SplitPending=true; single-register prohibitions enter with SplitPending=false (already minimal). - ReprobeLoopAsync delegates the per-pass work to RunReprobeOnceForTestAsync (also exposed for synchronous test driving). Each entry routes to BisectAndReprobeAsync (split-pending + multi-reg) or StraightReprobeAsync (single-reg / non-split-pending). - Bisection: split (start, end) at mid = (start+end)/2. Try (start, mid) and (mid+1, end) as separate coalesced reads. Each FAILED half re-enters the prohibition map with SplitPending = (its end > its start). SUCCEEDED halves vanish, freeing the planner to coalesce across them on the next scan. - Convergence: log2(span) re-probe ticks pin the prohibition to the actual single offending register(s). For a 100-register block with one protected address that's ~7 ticks. Tests (3 new ModbusCoalescingBisectionTests): - Bisection_Narrows_Multi_Register_Prohibition_Per_Reprobe — 11 tags 100..110 with protected address 105. After 4 re-probe passes the prohibition collapses from (100..110) → (100..105) → (103..105) → (105..105). - Bisection_Clears_When_Both_Halves_Are_Healthy — transient failure scenario; protection lifted before re-probe; both bisection halves succeed and the parent vanishes entirely. - Bisection_Splits_Into_Two_When_Both_Halves_Still_Fail — TwoHoleTransport with protected addresses 102 + 108 in the same coalesced range. After bisection both halves still fail (each contains one of the protected addresses); the prohibition map grows to 2 entries. 236 + 3 = 239 unit tests green. Solution build clean. |
||
|
|
9e4aae350b |
Task #151 — Modbus coalescing: periodic re-probe of auto-prohibitions
#148 introduced auto-prohibited coalesced ranges that persist for the driver lifetime. Long-running deployments with transient PLC permission changes (firmware update unlocking a previously-protected register, operator reconfiguring the device) had no recovery short of operator restart. Adds an opt-in background loop that re-probes each prohibition periodically: - ModbusDriverOptions.AutoProhibitReprobeInterval (TimeSpan?, default null = disabled). Set to e.g. TimeSpan.FromHours(1) to opt in. - _autoProhibited refactored from HashSet<key> to Dictionary<key, DateTime> so each entry tracks its last failure / last re-probe timestamp. - ReprobeLoopAsync runs on the same Task.Run pattern as ProbeLoopAsync; cancelled by ShutdownAsync. Each tick snapshots the prohibition set and issues a one-shot coalesced read per range. Successful re-probes drop the prohibition; failed ones bump the timestamp + leave the prohibition in place. - Communication failures during re-probe (transport-level) are treated the same as PLC-exception failures — the prohibition stays, but isn't upgraded to "permanent" since transports recover. The driver-instance health surface picks up the failure separately. - ShutdownAsync explicitly clears the prohibition set so a manual restart via ReinitializeAsync starts with a clean slate (matches the old "restart to clear" semantics). - Factory DTO + JSON binding extended with AutoProhibitReprobeMs field. Tests (2 new, additive to the 3 in ModbusCoalescingAutoRecoveryTests): - Reprobe_Clears_Prohibition_When_Range_Becomes_Healthy — protected register at 102 records prohibition; clearing the simulated protection + invoking the re-probe drops the prohibition. - Reprobe_Leaves_Prohibition_When_Range_Is_Still_Bad — re-probe on a still-failing range keeps the prohibition in place. Tests use a new internal RunReprobeOnceForTestAsync helper to fire one re-probe pass synchronously, so the suite doesn't have to wait on the background timer (the loop's timer behaviour is exercised implicitly via the InitializeAsync wire-up + the synchronous helper sharing the actual re-probe code path). 234 + 2 = 236 unit tests green. |
||
|
|
8de152df4f |
Task #149 — Modbus address-preview page + ImportEquipment help
The original task scope assumed a per-tag editor lived in EquipmentTab.razor or a similar surface. Reading the codebase confirmed that's not the case: tags are seeded via SQL (scripts/smoke/*) or arrive at runtime through ITagDiscovery; the Admin UI has no per-tag CRUD page today. Equipment import is for equipment metadata (Name / MachineCode / ZTag / SAPID / Identification) — not tag rows. Adjusted scope: 1. ModbusAddressPreview.razor — new standalone page at /modbus/address-preview. Hosts the ModbusAddressEditor component shipped in #145 + the family selector + a copy-pasteable grammar reference. Operators can sanity-check address-string syntax (40001:F:CDAB / HR1:I / V2000:F / D100:I etc.) without committing it to a config row first. 2. ImportEquipment.razor — appended a secondary alert banner clarifying that Modbus per-tag addressing isn't part of equipment import; points users at the Drivers tab + the new preview tool. Builds clean against the existing Admin app. The actual per-tag CRUD UI is still a separate piece of work — when it ships, it can drop in ModbusAddressEditor directly. The preview page acts as the canonical demonstration of how to use the component. Razor caveat: the grammar reference uses literal `<...>` syntax tokens that the Razor parser interprets as malformed elements when inlined in a <pre> block. Held as a string field (_grammarReference) and rendered through @ binding to sidestep the parser conflict. |
||
|
|
3b0e093002 |
Task #148 — Modbus block-coalescing: auto-recover from protected register holes
Pre-#148 behaviour: a coalesced FC03/FC04 read that crossed a write-only or PLC-fault register marked every member tag Bad until the operator manually flagged the offending tag with CoalesceProhibited. Healthy tags around the hole stayed broken indefinitely. Post-#148: two-stage recovery, no operator intervention needed. 1. Same-scan fallback: when a coalesced read fails with a Modbus exception (IllegalDataAddress, SlaveDeviceFailure, etc.), the planner does NOT mark members handled. The per-tag fallback in the same scan reads each member individually — non-protected members surface Good values immediately, and only the actual protected register stays Bad. 2. Cross-scan prohibition: the failed range (Unit, Region, Start, End) is recorded in a per-driver `_autoProhibited` set. On subsequent scans the planner checks each candidate merge against the set and refuses to re-form any block that overlaps a known-bad range. Net effect: after one scan with a failure, the protected range goes "per-tag mode" indefinitely while ranges around it keep coalescing normally. Communication failures (timeouts, socket drops) are NOT auto-prohibited — they're transport-level, not structural. The same coalesced read can succeed once the transport recovers; recording it as "permanently bad" would defeat coalescing for the whole driver instance. Auto-prohibition state lives for the driver lifetime and clears on ReinitializeAsync (operator restart). A periodic re-probe is a follow-up if deployments need it without a restart. Implementation: - Added `_autoProhibited` HashSet<(byte, ModbusRegion, ushort, ushort)> + `_autoProhibitedLock` on ModbusDriver. - `RangeIsAutoProhibited(unit, region, start, end)` overlap check called from the planner when forming blocks. - `RecordAutoProhibition(...)` called from the catch (ModbusException) branch. - The catch (Exception) branch (non-Modbus failures) keeps the pre-#148 "mark all Bad in this scan, don't auto-prohibit" behaviour. - Internal `AutoProhibitedRangeCount` accessor for tests. Tests (3 new ModbusCoalescingAutoRecoveryTests): - First_Failure_Falls_Back_To_PerTag_Same_Scan — three tags around a protected register at 102: T100 + T104 surface Good values via the per-tag fallback in the SAME scan; T102 surfaces the exception. - Second_Scan_Skips_Coalesced_Read_Of_Prohibited_Range — confirms scan 2 doesn't re-attempt the failed merge (no FC03 with quantity > 1 at the prohibited start). - Tags_Outside_Prohibited_Range_Still_Coalesce — separate cluster at HR 200..202 keeps coalescing normally even after the 100..104 cluster is prohibited. 234/234 unit tests green. Follow-ups intentionally NOT shipped (smaller, independent changes): - Bisection-style range narrowing — currently the prohibition range is the full failed block; the planner doesn't try to find the exact protected register. Operator-visible diagnostic + prohibition stays correct. - Periodic re-probe to clear stale prohibitions. - Surface auto-prohibited ranges through GetHostStatuses or a new diagnostic so the Admin UI can show what's been auto-isolated. |
||
|
|
0b7653d3b2 |
Task #147 — wire ModbusOptionsEditor into DriversTab
Branches the DriversTab driver-add form on driver type: - For DriverType=Modbus, render the typed <ModbusOptionsEditor> component shipped in #145 instead of the generic JSON textarea. - For other driver types, the existing textarea stays (other drivers ship their own typed editors per decision #94). On Save, when type is Modbus, the form serialises ModbusOptionsViewModel into the JSON DTO shape ModbusDriverFactoryExtensions consumes (host / port / unitId / family / keepAlive / reconnect / max*** / writeOnChangeOnly / etc.). Other types still pass the textarea contents verbatim. Drive-by fix: the DriverType dropdown listed "ModbusTcp" but the actual factory-registered name is "Modbus" — DriverInstanceBootstrapper would silently skip a row created with the old label because the factory lookup would miss. Renamed to match. Tests (2 new in ModbusOptionsViewModelTests): - DriversTab_Serialized_Defaults_RoundTrip_Through_Factory — unedited view-model serializes to a JSON the factory accepts; resulting ModbusDriverOptions matches the form defaults bit-for-bit. - DriversTab_Serializes_Edited_Values_Correctly — flipping Host / Port / UnitId / Family / MaxReadGap / WriteOnChangeOnly in the view model surfaces in the constructed driver's options. The serializer in the test mirrors DriversTab.razor's SerializeModbusOptions helper. If the form's serialization shape drifts, both must be updated together; that's the cost of testing through the JSON DTO without bUnit. Follow-up still open: the per-tag editor (ModbusAddressEditor wiring into EquipmentTab.razor + the bulk-import help-text update) — that's a separate surface that touches the equipment-row CRUD flow; covered as a follow-up when the equipment tag editor surface is next touched. |
||
|
|
dfd027ebca |
Task #146 — Modbus addressing: align type codes with Wonderware DASMBTCP + Ignition
Web verification (2026-04-25) against current vendor docs surfaced concrete grammar conflicts in the v1 suffix grammar shipped in #137. Hard cutover before the Admin UI rolls out widely so users don't paste `:I` from a Wonderware spreadsheet and silently get wrong-typed reads. Sources: - Wonderware DASMBTCP user guide https://cdn.logic-control.com/media/DASMBTCP.pdf - Ignition Modbus addressing (8.1) https://www.docs.inductiveautomation.com/docs/8.1/ignition-modules/opc-ua/opc-ua-drivers/modbus/modbus-addressing Type-code changes: | Code | Pre-#146 | Post-#146 | Vendor reference | |--------|----------|------------|------------------------------| | `:S` | (n/a) | Int16 | Wonderware DASMBTCP `S` | | `:US` | (n/a) | UInt16 | Ignition `HRUS` | | `:I` | Int16 | **Int32** | Wonderware `I` + Ignition `HRI` | | `:UI` | UInt16 | **UInt32** | Ignition `HRUI` | | `:I_64` | (n/a) | Int64 | Ignition `HRI_64` | | `:UI_64` | (n/a) | UInt64 | Ignition `HRUI_64` | | `:BCD_32`| (n/a) | BCD32 | Ignition `HRBCD_32` | Codes REMOVED (no clear vendor precedent + conflict with the new mapping): `:DI`, `:L`, `:UDI`, `:UL`, `:LI`, `:ULI`, `:LBCD`. Pre-#146 configs that use them get an "Unknown type code" diagnostic at parse time so users get a fast surface-level error rather than silent wrong-typed reads. Codes UNCHANGED (already vendor-aligned): `:BOOL`, `:F`, `:D`, `:BCD`, `:STR<n>`. Modicon 5/6-digit + mnemonic regions (HR/IR/C/DI) + bit suffix `.N` are also unchanged. Defaults: - Coils / DiscreteInputs → `BOOL` (unchanged) - HoldingRegisters / InputRegisters with no explicit type → Int16 (matches Ignition's bare `HR` default) Byte-order mnemonics (`:ABCD` / `:CDAB` / `:BADC` / `:DCBA`) are kept but documented as OtOpcUa-specific — they aren't in any major vendor's per-tag address string. Ignition uses a `-R` suffix per prefix; Wonderware configures word-order at the topic level. Tests: - 12 Type_Codes_Parse rows updated to assert the new mappings. - New Removed_Aliases_Are_Rejected (×7) confirms each pre-#146 alias now fails fast with "Unknown type code". - Worked_Example_Int16_Array uses the new `:S` code. - New Worked_Example_Int32_Array_Via_I_Code documents the `:I = Int32` vendor-alignment intent so a future "fix" doesn't accidentally regress. - Unknown_Type_Code_Rejected_With_Catalog updated to match the new error message ("Valid: BOOL, S, US, I, ..."). Docs: - docs/v2/modbus-addressing.md — table replaced with the post-#146 codes, each row cites its Wonderware / Ignition reference. New "Codes removed in #146" subsection documents the cutover. - docs/Driver.Modbus.Cli.md — example grammar list updated; explicit type-code reminder appended. 114 addressing tests + 231 driver tests still green. Solution build clean. |
||
|
|
858f300a61 |
Task #145 — Admin UI: expose new Modbus driver config
Two new Blazor components surface every Modbus knob added by #136-#144 so users can configure the driver without hand-editing DriverConfig JSON. ModbusAddressEditor.razor (live address-string parser preview): - Bound to a string AddressString + a Family / MelsecSubFamily hint. - On every input keystroke, runs ModbusAddressParser.TryParse and surfaces the resolved breakdown (Region, Offset, DataType, Bit, ByteOrder, ArrayCount, StringLength) inline as a green badge. - On parse error, shows the parser's diagnostic in red. - Re-uses the SAME parser the wire driver uses — grammar drift is impossible by construction. ModbusOptionsEditor.razor (driver-instance options panel): - Connection group (Host / Port / UnitId). - Family group (#144) with conditional MelsecSubFamily dropdown. - Keep-alive group (#139): Enabled / Time / Interval / RetryCount. - Reconnect group (#139): InitialDelay / MaxDelay / BackoffMultiplier. - Protocol group (#140): MaxRegistersPerRead / Write / Coils / ReadGap. - Behaviour toggles (#140 + #141): UseFC15 / UseFC16 / WriteOnChangeOnly. - Bound to ModbusOptionsViewModel — defaults match ModbusDriverOptions defaults so unedited rows produce the historical wire output verbatim. Architecture: - Admin project gains a ProjectReference to Driver.Modbus.Addressing (the shared parser assembly extracted in #136). Admin does NOT take a dep on Driver.Modbus itself — the addressing concerns are cleanly separated from the wire driver. - Same-namespace shared assembly means components reference ModbusAddressParser / ModbusFamily / etc. without prefix gymnastics. Tests: - ModbusOptionsViewModelTests (1 test) — pins every default in the view model against the corresponding ModbusDriverOptions default. A regression that flips an unedited row to a non-default value gets caught here. (Test references both Admin and Driver.Modbus to make the cross-assembly comparison.) - Live Blazor component testing requires bUnit, which isn't currently in the test setup; the parser logic the component wraps is fully covered by the 91 ModbusAddressParser tests in the addressing project, so the glue layer's behaviour is verifiable end-to-end already. Caveat: the wiring into the existing DriverInstance edit page lives in DriversTab.razor — that integration is left as a follow-up because it touches the cluster-edit workflow specifically and the components in this commit are framework-agnostic enough to drop in. The components build clean against the existing Admin project; no behavioural change to other tabs. |
||
|
|
366212417c |
Task #143 — Modbus block-read coalescing (with max-gap knob)
Adds a coalescing read planner that merges nearby tags into single FC03/FC04 PDUs, opt-in via ModbusDriverOptions.MaxReadGap. Default 0 = no coalescing (every tag gets its own PDU — preserves pre-#143 wire output). Worked example with MaxReadGap=10: T1 @ HR 100 (Int16, 1 reg) T2 @ HR 102 (Int16, 1 reg, gap 1 → joins block) T3 @ HR 110 (Float32, 2 regs, gap 7 → joins block) T4 @ HR 200 (Int16, 1 reg, gap 89 → splits, separate read) → 2 PDUs total: FC03 start=100 quantity=12 + FC03 start=200 quantity=1. Planner: - Eligible tags: known + register region (HR/IR) + scalar + not String / BitInRegister / array + not CoalesceProhibited. - Groups by (UnitId, Region) — never coalesces across slaves or regions. - Sorts by start address; merges when (next.start - last.end - 1) ≤ MaxReadGap AND the resulting span ≤ MaxRegistersPerRead. Otherwise opens a new block. - Single-tag blocks are deferred to the per-tag path so WriteOnChange cache semantics stay correct without duplication. - Per-block failure marks every member tag Bad and degrades health — same semantics the per-tag path has, but at the block granularity. Per-tag escape hatch ModbusTagDefinition.CoalesceProhibited (bool, default false) — when true, the tag is read in isolation regardless of MaxReadGap. For PLCs with protected register holes between adjacent tags. Tests (7 new ModbusCoalescingTests): - MaxReadGap=0 keeps the per-tag behavior (2 reads for 2 tags). - MaxReadGap=2 merges 3 tags within 5 registers into 1 read of qty=5. - MaxReadGap=10 splits T1+T2 from T3 when the gap exceeds the threshold. - CoalesceProhibited tag reads alone even when neighbours are eligible. - Coalescing never crosses UnitId boundaries (multi-slave gateway safety). - MaxRegistersPerRead caps a would-be block; planner falls back to separate reads when the merged span would exceed the cap. - Per-tag values surface independently after coalescing (slice-math sanity). Existing 220 unit tests still green; total 224 pass with the new file (tests are additive, no regressions). Follow-up: auto-split-on-protected-hole isn't shipped — a coalesced read that hits an Illegal Data Address right now marks every member Bad until the operator sets CoalesceProhibited on the offending tag. Tracked implicitly by #138's e2e drill against a pymodbus profile with a protected hole mid-block. |
||
|
|
ad7d811f69 |
Task #142 — Modbus multi-unit-ID per TCP connection (gateway support)
Lifts the previous "one driver = one slave" assumption so a single Modbus driver instance can front N RTU slaves behind one Ethernet gateway (Anybus, ProSoft, Lantronix style). Each tag carries an optional UnitId that drives the MBAP unit-id byte per-PDU, and the IPerCallHostResolver contract surfaces per-slave host strings so per-PLC circuit breakers fire per-slave (matches the AB CIP template documented in docs/v2/multi-host-dispatch.md). Changes: - ModbusTagDefinition gains optional UnitId (byte?). Null = use driver-level ModbusDriverOptions.UnitId (preserves single-slave deployments verbatim). - ResolveUnitId(tag) helper computed once per ReadOneAsync / WriteOneAsync call; passed through ReadRegisterBlockAsync / ReadBitBlockAsync / ReadRegisterBlockChunkedAsync / ReadBitBlockChunkedAsync explicitly. The probe loop continues using driver-level UnitId (the probe is a connection-health check, not slave-specific). - ModbusDriver implements IPerCallHostResolver. ResolveHost(fullReference) returns "host:port/unitN" — distinct strings per slave so the resilience pipeline keys breakers on the right granularity. Unknown references fall back to the bare HostName (single-slave behaviour). - BitInRegister RMW path also threads the per-tag UnitId through both the read and write halves so a multi-slave deployment stays correct under bit- level writes. - Factory DTO + JSON binding extended with the per-tag UnitId field. Tests (4 new ModbusMultiUnitTests): - Per-tag UnitId routes to the correct slave in the MBAP header (driver-level UnitId=99 must NOT appear when both tags override). - Tag without override falls back to driver-level UnitId. - IPerCallHostResolver returns distinct "host:port/unitN" strings per slave. - Unknown reference returns the bare HostName fallback. Existing 220 unit tests + 107 addressing tests still green. Per-PLC breaker isolation under simulated dead slaves is verifiable via the existing AB CIP test infra; live coverage lands as an integration test in the #138 docs/e2e refresh. |
||
|
|
4cf0b4eb73 |
Task #144 — Modbus family-native parser branch (DL205 / MELSEC)
Promotes DirectLogicAddress + MelsecAddress from "utility helpers an engineer calls manually" to "first-class branch of ModbusAddressParser." Users can now paste DL205-native (V2000, Y0, C100, X17, SP10) and MELSEC-native (D100, M50, X20 hex/octal, Y0) addresses directly into TagConfig and the parser handles the PLC-native → Modbus PDU translation. Changes: - Both helper files moved into the shared Driver.Modbus.Addressing assembly (same namespace, zero-churn for callers). Required because the parser needs to call them and the dependency direction is parser→helpers, not the other way. - New ModbusFamily enum (Generic / DL205 / MELSEC) on ModbusDriverOptions.Family. Generic preserves pre-#144 behaviour exactly. - ModbusDriverOptions.MelsecSubFamily picks the X/Y notation (Q_L_iQR hex vs F_iQF octal). Default Q_L_iQR. - ModbusAddressParser.Parse now takes optional family + sub-family hints. When non-Generic, family-native parsing runs FIRST; on miss falls back to Modicon / mnemonic. Cross-family ambiguity (C100 = Modicon coil under Generic, DL205 control relay under DL205) is unambiguous within one driver instance. - Suffix grammar composes with native addresses: V2000:F:CDAB:5 parses end-to-end as DL205 V-memory at PDU 1024 + Float32 + word-swap + array of 5. - Bit suffix composes too: V2000.7 parses as bit 7 of HR[1024]. - Factory DTO fields Family / MelsecSubFamily flow through to BuildTag so the JSON binding can drive everything per-driver. Tests: 16 new ModbusFamilyParserTests covering DL205 V/Y/C/X/SP, MELSEC D/M/X/Y, sub-family hex-vs-octal disambiguation, cross-family C100 ambiguity, fallback to Modicon when native misses, and grammar composition with bit/ byte-order/array modifiers. Existing 91 parser tests still green; 220 driver tests still green. Caveat: bank-base offsets for MELSEC X/Y/M default to 0 in the grammar string. Sites with non-zero "Modbus Device Assignment Parameter" bases must use the structured tag form to override — addressed in the docs refresh (#138). |
||
|
|
4bffe879c5 |
Task #141 — Modbus subscribe-side knobs (deadband + write-on-change)
Two driver-side filters that ≥5 of 6 surveyed vendors expose: 1. Per-tag Deadband (double?, on ModbusTagDefinition) — when set, the PollGroupEngine onChange callback suppresses publishes whose distance from the last-published value is below the threshold. Reduces wire traffic to OPC UA clients on noisy analog signals (flow meters, temperatures). Numeric scalar types only — Bool / BitInRegister / String / array tags publish unconditionally. 2. WriteOnChangeOnly (bool, on ModbusDriverOptions) — when true, the driver short-circuits writes whose value matches the most recent successful write to that tag. Saves PLC bandwidth on clients that re-publish the same setpoint every scan. Cache invalidates on any read that returns a different value, so HMI-side changes don't get masked. Both default off so existing deployments see no behaviour change. Implementation: - ShouldPublish guard wraps the existing OnDataChange invocation. First sample always passes through (no baseline); subsequent samples compare via Convert.ToDouble for the cross-numeric-type math. - IsRedundantWrite check at the top of WriteAsync; on success the cache is populated. Object.Equals handles boxed-numeric equality; arrays are excluded (reference-equality would never match anyway). - ReadAsync invalidates the WriteOnChangeOnly cache when the new value differs from the cached last-written value. Tests (5 new ModbusSubscribeOptionsTests): - Deadband suppresses sub-threshold changes (100 → 102 → 106 → 107 with deadband=5 publishes 100 and 106 only). - Deadband=null still publishes every change. - WriteOnChangeOnly suppresses 3 identical 42 writes (only first hits wire). - WriteOnChangeOnly default false hits the wire every time. - Read-divergence cache invalidation: external panel write to 99, our client's re-write of 42 must NOT be suppressed. 220/220 unit tests green; existing ProtocolOptions tests hardened against probe-loop noise by disabling the probe in their fixtures. |
||
|
|
55f4044a69 |
Task #140 — Modbus protocol-behavior knobs
Adds ModbusDriverOptions knobs that ≥4 of 6 surveyed vendors expose: 1. MaxCoilsPerRead (ushort, default 2000) — separate from MaxRegistersPerRead because coil packing (1 bit per coil) and register packing (16 bits each) have different spec ceilings. Coil-array reads above the cap auto-chunk the same way register reads have always done. New ReadBitBlockChunkedAsync re-assembles per-chunk LSB-first bitmaps into one logical bitmap. 2. UseFC15ForSingleCoilWrites (default false) — forces FC15 (Write Multiple Coils with quantity=1) for single-coil writes instead of the default FC05 (Write Single Coil). Safety / audit PLCs that only accept the multi-write codes need this. 3. UseFC16ForSingleRegisterWrites (default false) — same idea for FC16 vs FC06 on single holding-register writes. 4. DisableFC23 (default false) — placeholder no-op for the future block-read coalescing (#143) work that may opt into FC23 (Read/Write Multiple Registers). Lets deployments pre-disable FC23 for PLCs that won't accept it, before we ship the optimisation that emits it. Defaults preserve the historical wire output bit-for-bit (FC05/FC06 for singles, no chunking under 2000 coils, no FC23). Factory DTO + JSON-binding extended with parallel fields. 6 new ModbusProtocolOptionsTests covering: defaults, FC05→FC15 forcing, FC06→FC16 forcing, MaxCoilsPerRead chunking math (2500 coils / 2000 cap → 2 reads of 2000 + 500). Existing 209 unit tests still green. |
||
|
|
6cf20131fe |
Task #139 — Modbus connection-layer config knobs (keep-alive / idle / reconnect)
Promotes the previously hardcoded transport-layer settings to ModbusDriverOptions so users can tune them through DriverConfig JSON without recompiling. Three new option groups: 1. KeepAlive (ModbusKeepAliveOptions): Enabled / Time / Interval / RetryCount. Defaults preserve the historical PR 53 wire output exactly (Enabled=true, Time=30s, Interval=10s, RetryCount=3). Set Enabled=false for PLCs that reject SO_KEEPALIVE. 2. IdleDisconnectTimeout (TimeSpan?): when set, the transport tracks last-PDU- success and proactively closes + reconnects on the next request after the threshold. Defends against silent NAT / firewall socket reaping. Default null = disabled (no behaviour change). 3. Reconnect (ModbusReconnectOptions): InitialDelay / MaxDelay / BackoffMultiplier for the post-drop reconnect loop. Defaults (InitialDelay=0, MaxDelay=30s, Multiplier=2.0) preserve the historical immediate-retry behaviour for the first attempt and add geometric backoff only if the reconnect itself fails. Capped at 10 attempts before propagating. ModbusTcpTransport ctor extended with optional keepAlive / idleDisconnect / reconnect parameters; existing 4-arg call sites continue to compile. Factory DTO gains parallel KeepAlive / IdleDisconnectMs / Reconnect fields with default-aware binding. 5 new ModbusConnectionOptionsTests covering the default-preservation contract (every default field matches pre-#139) and the JSON-binding round-trip for each knob group. Existing 204 unit tests still green. |
||
|
|
850b816873 |
Task #137 — Modbus per-tag suffix grammar (type / bit / byte-order / array)
Adds the full Wonderware/Kepware/Ignition-style address suffix grammar so users paste tag spreadsheets without per-tag manual translation: <region><offset>[.<bit>][:<type>[<len>]][:<order>][:<count>] Examples that now parse end-to-end: 40001 HoldingRegisters[0], Int16 400001 same, 6-digit form 40001.5 bit 5 of HR[0] 40001:F Float32 (HR[0..1]) 40001:F:CDAB word-swapped Float32 40001:STR20 20-char ASCII string HR1:DI Int32 via mnemonic region C100 Coils[99] (mnemonic) 40001:F:5 Float32[5] array (3-field shorthand) 40001:I:CDAB:10 Int16[10] word-swapped (4-field strict) Driver-side plumbing: - ModbusAddressParser + ParsedModbusAddress in the shared Addressing assembly. 91 parser tests (every grammar variant + malformed shapes). - ModbusDataType / ModbusByteOrder moved to shared (with the same namespace so callers compile unchanged). ModbusByteOrder gains ByteSwap (BADC) and FullReverse (DCBA) alongside the existing BigEndian (ABCD) and WordSwap (CDAB). - NormalizeWordOrder extended to honor all four orders for both 4-byte and 8-byte values. Old WordSwap behavior preserved bit-for-bit. - ModbusTagDefinition gains optional ArrayCount. - ReadOneAsync / WriteOneAsync handle array fan-out: one FC03/04 read covers N consecutive register-typed elements, decoded into a typed array (short[], float[], etc.). Coil arrays use FC01 reads + FC15 writes (FakeTransport in tests gains FC15 support to match). - DriverAttributeInfo IsArray / ArrayDim flow from ArrayCount so the OPC UA address space surfaces ValueRank=1 + ArrayDimensions to clients. - ModbusDriverFactoryExtensions gains AddressString DTO field. When present, the parser drives Region/Address/DataType/ByteOrder/Bit/ StringLength/ArrayCount; structured fields (Writable, WriteIdempotent, StringByteOrder) still come from the DTO. Existing structured tag rows keep working unchanged. Tests: 91 parser unit tests (Driver.Modbus.Addressing.Tests, all green) + 204 driver tests including new ModbusByteOrderTests (BADC/DCBA roundtrips across Int32/Float32/Float64) and ModbusArrayTests (Int16[5], Float32[3] CDAB, Coil[10], length-mismatch error, IsArray/ArrayDim discovery). Solution-wide build clean. Caveat: grammar names (type codes, byte-order mnemonics, the :count shorthand) were synthesized from training-era vendor docs. Verify against current Kepware Modbus Ethernet Driver Help and Ignition Modbus Addressing manuals before freezing for production deployments — naming may need a back-compat layer if vendor wording has shifted. |
||
|
|
501d8f494b |
Task #136 — Modicon address-string parser (5/6-digit) + shared addressing assembly
Foundation for the Modbus addressing-grammar work tracked in #137-#145. Adds ModbusModiconAddress.Parse / TryParse that turns classic Modicon strings (40001 / 400001 / 30001 / 00001 / 10001) into (Region, ushort PduOffset). Also extracts ModbusRegion to a new Driver.Modbus.Addressing assembly so the Admin UI (#145) can reference the addressing surface without taking a dep on the wire driver. The new assembly intentionally extends the same ZB.MOM.WW.OtOpcUa.Driver.Modbus namespace as the driver — callers see the type as if it lived in one place; only the project layout changes. No existing call site needed editing (zero-churn move). Behaviour: - Single leading digit selects region (0=Coils, 1=DiscreteInputs, 3=InputRegisters, 4=HoldingRegisters). - 5-digit form: trailing 4 digits are 1-based register, supports 1..9999. - 6-digit form: trailing 5 digits are 1-based register, supports 1..65536 (full PDU address space). - Strict 5-or-6 length check; whitespace trimmed; clear FormatException diagnostics for every malformed shape (wrong length, non-digit body, illegal leading digit, register zero, register overflow). 29/29 new unit tests pass. Full Driver.Modbus suite (182 tests) and the solution-wide build still green after the ModbusRegion move. |
||
|
|
75c07149d4 |
Task #124 — Phase 6.2 multi-user authz interop matrix + close LdapGroups gap
The Phase 6.2 evaluator was wired but received no input in production: RoleBasedIdentity (the IUserIdentity our LDAP path produces) implemented IRoleBearer but not ILdapGroupsBearer, so AuthorizationGate.BuildSessionState always returned null and the gate lax-mode-allowed every request. UserAuthResult also never carried the resolved LDAP groups, only the role-mapped strings. Closing the gap so the evaluator gets real data: - UserAuthResult adds Groups alongside Roles. LdapUserAuthenticator now surfaces the raw RDN values (ReadOnly / WriteOperate / ...) it already collected during the directory query. Roles stay separate per decision #150 (control-plane Admin role mapping vs data-plane NodeAcl key). - RoleBasedIdentity implements ILdapGroupsBearer so AuthorizationGate sees the groups via the same seam unit tests already use. ThreeUserInteropMatrixTests drives the closure end-to-end against the live GLAuth dev directory: - 5 distinct group memberships (readonly / writeop / writetune / writeconfig / alarmack) plus the multi-group admin user - Each is bound through the real LdapUserAuthenticator - Resolved groups feed an LdapBoundIdentity that goes through the strict-mode AuthorizationGate against a seeded TriePermissionEvaluator - 31 InlineData rows assert the role × operation matrix; failures pinpoint the exact (user, op) cell The remaining wire-level leg of #124 — a real OPC UA client driving UserName tokens through an encrypted endpoint policy — still needs a deployment knob and stays a manual cross-vendor smoke (#119 / #124 manual scope). The doc audit note in admin-ui-phase-6-status.md is updated to reflect what's now auto'd vs what stays manual. 33/33 new tests pass against live GLAuth; existing 270 non-LiveLdap tests in Server.Tests still pass; Core.Tests 205/205, Admin.Tests 109/109. The 7 integration-test failures observed during this run pre-exist this commit (NodeId-scheme regression from #134) and are tracked separately as #135. |
||
|
|
bd6568bcbd |
Phase 6.1 Stream B.4 — wire ScheduledRecycleHostedService into bootstrap
Task #125 / #137. The hosted service + scheduler classes already shipped; this commit connects them to the published-generation driver list so a Tier C driver with `RecycleIntervalSeconds` in its `ResilienceConfig` actually gets an armed scheduler at bootstrap. Wiring: - `DriverFactoryRegistry.Register` gains an optional `DriverTier` parameter (default Tier.A). Existing call sites unchanged — `GalaxyProxyDriverFactoryExtensions.Register` explicitly passes Tier.C so the bootstrapper can identify out-of-process drivers without a per-driver-type allow-list. - `DriverResilienceOptions` + parser grow `RecycleIntervalSeconds`. Tier A/B values are rejected with a diagnostic (decision #74 — recycling an in-process driver would kill every OPC UA session). Non-positive values are rejected the same way. - `DriverInstanceBootstrapper` auto-arms a `ScheduledRecycleScheduler` after a successful driver register when: (1) the registered tier is C, (2) the row's ResilienceConfig carries a positive recycle interval, (3) DI has an `IDriverSupervisor` keyed by that `DriverInstanceId`. Missing supervisor → warn + skip (no crash). That keeps the wiring harmless by default: no driver ships a supervisor today, so the hosted service runs with zero schedulers out of the box. - `Program.cs` registers `ScheduledRecycleHostedService` as singleton (shared with `DriverInstanceBootstrapper`) + hosted service (drives the tick loop). Constructor changes on the bootstrapper ripple into DI resolution automatically. Tests: 4 new parser tests covering RecycleIntervalSeconds on Tier C happy path, null default, Tier A/B rejection, non-positive rejection. Existing 283 Server.Tests + 200 Core.Tests all still green. No behavioural change for existing deployments: Galaxy driver + any future Tier C driver gain the opt-in automatically; Tier A/B drivers (FOCAS, Modbus, S7, AB CIP, AB Legacy, TwinCAT) are structurally excluded. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
69e1d320ac |
Cold-start guard for script engines — skip evaluation with empty upstream
Both VirtualTagEngine and ScriptedAlarmEngine share a pattern: the BuildReadCache helper iterates the script's declared input set, reading from _valueCache with a fallback to _upstream.ReadTag. When an upstream tag hasn't yet delivered its first subscription push, ReadTag returns a DataValueSnapshot with a null Value and BadNotConnected quality. User scripts then cast `(double)ctx.GetTag(path).Value` unconditionally and throw NullReferenceException — once per evaluation tick until the cache fills, spamming the log with identical stack traces. The existing catch block recovered (kept the prior state) but didn't silence the churn. Add AreInputsReady(cache) to both engines: return true only when every entry has a non-null Value and a non-Bad StatusCode (Good + Uncertain are both considered ready). Skip script evaluation when the check returns false — the engine holds the prior state (alarm) or the prior snapshot (virtual tag) until upstream delivers. Eliminates the cold- start NRE spam at root without changing the script-engine contract. Also: fix $changeLines.Count in test-galaxy.ps1 — PowerShell's Set-StrictMode -Version 3.0 errors on .Count when Where-Object returns 0 or 1 items. Wrap in `@(...)` to force an array; same pattern the sibling _common.ps1 already uses in Write-Summary for the same reason. Task #112 — the Galaxy live E2E now passes 3/7 stages (probe + source read + reverse-bridge-ACL). The remaining 4 stages (virtual-tag, subscribe-sees-change, alarm-fires, history-read) are deployment- specific: MoveInBatchID is idle in this Galaxy + its AccessLevel blocks writes + it's not historized. Cold-start behaviour is now correct, so once the seed points at a live attribute those stages should light up. Tests: 36/36 VirtualTags.Tests + 47/47 ScriptedAlarms.Tests green. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
8be82e02c2 |
Path-based NodeIds — decouple client contract from driver address
The pre-refactor design minted OPC UA NodeIds directly from the driver's
FullReference (the native-address string). That had three long-term
problems:
1. OPC UA Part 3 §5.2.2 requires NodeIds to be immutable across a node's
lifetime. A rename of the underlying device address — Galaxy attribute,
S7 tag, Modbus register alias — changed the NodeId and broke every
client that had pinned the previous identifier.
2. Two drivers with coincidentally-matching native addresses (e.g. `temp`
in Modbus and `temp` in S7 under different Equipment rows) collided on
the NodeId identifier.
3. TagConfig was being placed verbatim on the wire; for drivers whose
TagConfig is JSON (every driver shipped today, per the
CK_Tag_TagConfig_IsJson check constraint), clients saw the raw JSON
blob as the NodeId string.
Refactor:
* DriverNodeManager.Variable now mints a stable path-based NodeId
`{driverId}/{folder-path}/{browseName}` and records the driver-side
FullReference in a new _fullRefByNodeId map. OnReadValue / OnWriteValue
/ ResolveFullRef look the FullReference up via that map instead of
casting NodeId.Identifier. The old cast path is preserved as a
fallback so any test fixture that still registers variables with
FullRef-shaped NodeIds keeps working.
* EquipmentNodeWalker.AddTagVariable now extracts the cross-driver
`FullName` field from Tag.TagConfig before handing the address to
DriverAttributeInfo. Every shipped driver stores the wire reference in
TagConfig[FullName]; falling back to the raw string covers any future
driver that wants an opaque non-JSON address. ExtractFullName is
exposed internal for unit coverage.
* scripts/e2e/test-galaxy.ps1 defaults updated to the new path-based
NodeIds. Verified live against p7-smoke-galaxy on the dev box:
`ns=2;s=p7-smoke-galaxy/lab-floor/galaxy-line/reactor-1/Source` reads
return Status=0x00000000 with a real Galaxy byte-array value.
Test suite: 195/195 Core.Tests + 283/283 Server.Tests green. Five new
ExtractFullName / FullName-passthrough tests added.
Task #112 GA-3 — golden-path read verified end-to-end; remaining E2E
script stages still blocked on pre-existing issues (ScriptedAlarm
predicate NRE on empty upstream cache, PowerShell $changeLines.Count
guard), tracked separately.
Task #134 — complete.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|
||
|
|
d11dd0520b |
Galaxy IPC unblock — live dev-box E2E path
Three root-cause fixes to get an elevated dev-box shell past session open through to real MXAccess reads: 1. PipeAcl — drop BUILTIN\Administrators deny ACE. UAC's filtered token carries the Admins SID as deny-only, so the deny fired even from non-elevated admin-account shells. The per-connection SID check in PipeServer.VerifyCaller remains the real authorization boundary. 2. PipeServer — swap the Hello-read / VerifyCaller order. ImpersonateNamedPipeClient returns ERROR_CANNOT_IMPERSONATE until at least one frame has been read from the pipe; reading Hello first satisfies that rule. Previously the ACL deny-first path masked this race — removing the deny ACE exposed it. 3. GalaxyIpcClient — add a background reader + single pending-response slot. A RuntimeStatusChange event between OpenSessionRequest and OpenSessionResponse used to satisfy the caller's single ReadFrameAsync and fail CallAsync with "Expected OpenSessionResponse, got RuntimeStatusChange". The reader now routes response kinds (and ErrorResponse) to the pending TCS and everything else to a handler the driver registers in InitializeAsync. The Proxy was already set up to raise managed events from RaiseDataChange / RaiseAlarmEvent / OnHostConnectivityUpdate — those helpers had no caller until now. 4. RedundancyPublisherHostedService — swallow BadServerHalted while polling host.Server.CurrentInstance. StandardServer throws that code during startup rather than returning null, so the first poll attempt crashed the BackgroundService (and the host) before OnServerStarted ran. This race was latent behind the Galaxy init failure above. Updates docs that described the Admins deny ACE + mandatory non-elevated shells, and drops the admin-skip guards from every Galaxy integration + E2E fixture that had them (IpcHandshakeIntegrationTests, EndToEndIpcTests, ParityFixture, LiveStackFixture, HostSubprocessParityTests). Adds GalaxyIpcClientRoutingTests covering the router's request/response match, ErrorResponse, event-between-call, idle event, and peer-close paths. Verified live on the dev box against the p7-smoke cluster (gen 6): driver registered=1 failedInit=0, Phase 7 bridge subscribed, OPC UA server up on 4840, MXAccess read round-trip returns real data with Status=0x00000000. Task #112 — partial: Galaxy live stack is functional end-to-end. The supplied test-galaxy.ps1 script still fails because the UNS walker encodes TagConfig JSON as the tag's NodeId instead of the seeded TagId (pre-existing; separate issue from this commit). Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
fb6dd3478d |
Phase 6.2 Stream C wiring — AuthorizationBootstrap + OpcUaApplicationHost.SetAuthorization
Closes task #133 — the "authz gate is inert in production" blocker surfaced during task #123. Before this commit, every ACL check on the six dispatch surfaces (Read, Write, HistoryRead, Browse, CreateMonitoredItems, Call) short-circuited to allow because Program.cs constructed OpcUaApplicationHost without passing authzGate or scopeResolver. New pieces: - `AuthorizationOptions` — bound to `Node:Authorization` in appsettings.json. `Enabled` (default false) is the master switch; `StrictMode` (default false) controls the anonymous / no-LDAP-groups fallback behaviour. - `AuthorizationBootstrap` — singleton service that loads `NodeAcl` rows for the published generation, builds a `PermissionTrieCache` + `AuthorizationGate`, merges every registered driver's `EquipmentNamespaceContent` through `ScopePathIndexBuilder` into one full-path `NodeScopeResolver`. Returns `(null, null)` when disabled or when no generation is Published yet. - `DriverEquipmentContentRegistry.Snapshot()` — new method returning a defensive copy of the driver → content map so the bootstrap can iterate without holding the lock. - `OpcUaApplicationHost.SetAuthorization(gate, resolver)` — late-bind method matching the existing `SetPhase7Sources` pattern. Must run before `StartAsync`; rejects post-start rebinding with InvalidOperationException. - `OpcUaServerService.ExecuteAsync` calls `AuthorizationBootstrap.BuildAsync` after `PopulateEquipmentContentAsync` and before `applicationHost.StartAsync`, in the same window that `SetPhase7Sources` runs. Behaviour change - Default (Enabled=false): no behaviour change — the gate stays null, all six dispatch surfaces run unchanged. Safe for any existing deployment on upgrade. - Enabled=true with StrictMode=false: identities carrying LDAP groups are evaluated against the trie; anonymous / no-groups identities pass through (v1 legacy-client compatibility). - Enabled=true with StrictMode=true: everything evaluates. Anonymous or no-groups identities are denied. Follow-up not covered here: rebind the gate+resolver on generation refresh (the `GenerationRefreshHostedService` that shipped earlier in this session). Today the gate only reflects the bootstrap generation — operators publishing new ACL changes need a process restart to see them. Matches the current driver-hot-reload limitation and is tracked in the existing 6.3 follow-up bullet. Docs: v2-release-readiness.md Phase 6.2 Stream C.12 bullet flipped to Closed with operator-facing config pointer (`Node:Authorization:Enabled`). All 283/283 Server.Tests still pass. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
ded292ecd7 |
Phase 6.2 Stream C — Call + Alarm Acknowledge/Confirm gating
Closes task #122 (Acknowledge + Confirm + generic Call — Shelve stays as a follow-up pending per-instance method-NodeId resolution). Before this commit any session with a connected channel could invoke method nodes on driver-materialized equipment — including alarm Acknowledge / Confirm. Combined with the Browse + CreateMonitoredItems gates that landed earlier in Stream C, this was the last service-layer entry point where a session could still affect state without passing the authz trie. Implementation on DriverNodeManager: - `Call` override — pre-iterates methodsToCall, gates each through AuthorizationGate with the operation kind returned by MapCallOperation. Denied calls get errors[i] = BadUserAccessDenied before delegating to base.Call. - `MapCallOperation(NodeId methodId)` — maps well-known Part 9 method NodeIds to dedicated operation kinds: MethodIds.AcknowledgeableConditionType_Acknowledge → OpcUaOperation.AlarmAcknowledge MethodIds.AcknowledgeableConditionType_Confirm → OpcUaOperation.AlarmConfirm everything else → OpcUaOperation.Call Lets the ACL distinguish "can acknowledge alarms" from "can invoke arbitrary methods" without conflating the two roles. - Shelve dispatch paths through per-instance ShelvedStateMachine methods with dynamic NodeIds that can't be constant-matched — falls through to generic Call. Fine-grained OpcUaOperation.AlarmShelve is a follow- up when the method-invocation path grows a "method-role" annotation. Extracted GateCallMethodRequests + MapCallOperation as static internal for unit-testability. 8 new tests (MapCallOperation Acknowledge / Confirm / generic; gate-null no-op, denied-Acknowledge, allowed- Acknowledge, mixed-batch, pre-populated-error-preserved). Server.Tests 269 → 277. Known follow-ups: - Shelve per-operation gating (see above). - TranslateBrowsePathsToNodeIds gating (Browse follow-up from #120). Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
6a6b0f56f2 |
Phase 6.2 Stream C — CreateMonitoredItems per-item gating
Closes task #121 (partial — creation-time gate; decision #153 per-item revocation stamp is a follow-up). Before this commit a session could subscribe to any node via CreateMonitoredItems, even nodes where Read was denied — the subscription would surface BadUserAccessDenied on each data-change read, but the client saw a successful CreateMonitoredItems response and held the subscription open, wasting resources and leaking the address-space shape through the item metadata. New override on DriverNodeManager.CreateMonitoredItems: - Pre-iterates itemsToCreate, gates each through AuthorizationGate with OpcUaOperation.CreateMonitoredItems at the target node's scope. - For denied slots: sets errors[i] = new ServiceResult( StatusCodes.BadUserAccessDenied). The OPC Foundation base stack honours pre-populated non-success errors and skips item creation for those slots — the subscription never holds a handle to a denied node. - Preserves prior errors (e.g. BadNodeIdUnknown) — first diagnosis wins. - Non-string-identifier references (stack-synthesized numeric ids) bypass the gate. Extracted the pure filter logic into GateMonitoredItemCreateRequests(items, errors, identity, gate, scopeResolver) — static internal, unit-testable without the OPC UA server stack. Tests — 6 new in MonitoredItemGatingTests.cs (gate-null no-op, denied-gets-BadUserAccessDenied, allowed-passes, mixed-batch-denies- per-item, pre-populated-error-preserved, numeric-id-bypass). Server.Tests 263 → 269. Known follow-ups: - Per-item (AuthGenerationId, MembershipVersion) stamp (decision #153) for detecting revocation mid-subscription — needs subscription-layer plumbing. - TransferSubscriptions not yet wired (same pattern, smaller scope). Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
e8b8541554 |
Phase 6.2 Stream C — Browse gating on DriverNodeManager
Closes task #120 (partial — strict point-check; ancestor-visibility implication is a follow-up). Before this commit DriverNodeManager exposed every materialized node to every browsing session regardless of the user's ACL. Read + Write + HistoryRead were already gated through AuthorizationGate in Phase 6.2 Stream C core; Browse was the one surface where the session could still enumerate nodes it had no permission to touch, discovering structure even when reads failed with BadUserAccessDenied. Implementation - New `Browse` override on DriverNodeManager that calls base.Browse first (lets the stack populate the reference list normally), then post-filters the IList<ReferenceDescription> so denied nodes are removed silently. OPC UA convention: Browse filtering is invisible to the client; no BadUserAccessDenied surfaces. - Extracted the filter loop into the static internal `FilterBrowseReferences(references, userIdentity, gate, scopeResolver)` so the policy is unit-testable without standing up the full OPC UA server stack. - Non-string NodeId identifiers (stack-synthesized standard-type references with numeric identifiers) bypass the gate — only driver- materialized nodes key into the authz trie. - When AuthorizationGate or NodeScopeResolver is null, the filter is a no-op — preserves the pre-Phase-6.2 dispatch path for integration tests that construct DriverNodeManager without authz. Tests — 6 new in BrowseGatingTests.cs (gate-null no-op, empty-list no-op, denied-removed, allowed-passes-through, numeric-id bypass, lax-mode null-identity keeps references). Server.Tests 257 → 263. Known follow-up (tracked implicitly under #120 re-scope): - Ancestor-visibility implication (acl-design.md §Browse line 111): a user with Read at `Line/Tag` should be able to Browse `Line` even without an explicit Browse grant. Current filter does a strict point-check. Proper fix needs TriePermissionEvaluator to expose a "subtree-has-any-grant" query. - TranslateBrowsePathsToNodeIds not yet filtered (same extension pattern; small follow-up). Docs: v2-release-readiness.md Phase 6.2 Stream C hardening list marks the Browse bullet struck-through with "Partial" close-out note. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
a23de2a7e4 |
Phase 6.3 A.2 + D.1 — GenerationRefreshHostedService: poll + lease-wrap apply
Closes tasks #132 + #118 (GA hardening backlog). Before this commit, the Server only observed the generation in force at process start (SealedBootstrap). Peer-published generations accumulated in the shared config DB while the running node kept serving the generation it had sealed on boot. Two consequences: 1. Operator role-swaps required a process restart — Admin publishes a new generation, but the Server's RedundancyCoordinator never re-read the topology. 2. ApplyLeaseRegistry had no apply to wrap. ServiceLevelBand sat at PrimaryHealthy (255) during every publish because nothing opened a lease; PrimaryMidApply (200) was effectively dead code. New GenerationRefreshHostedService (src/.../Server/Hosting/): - Polls sp_GetCurrentGenerationForCluster every 5s (tunable). - On change: opens leases.BeginApplyLease(newGenerationId, Guid.NewGuid()), calls coordinator.RefreshAsync inside the `await using`, releases on scope exit (success / exception / cancellation via IAsyncDisposable). - Diagnostic properties: LastAppliedGenerationId, TickCount, RefreshCount. - Delegate-injected currentGenerationQuery for test drive-through; real path is the private static DefaultQueryCurrentGenerationAsync. - Registered as HostedService in Program.cs alongside the Phase 6.3 redundancy / peer-probe stack. Scope intentionally narrow: only the coordinator refreshes today. Driver re-init, virtual-tag re-bind, script-engine reload remain as follow-up wiring. The lease wrap is the right seam for those subscribers to hook once they grow hot-reload support — the doc comments say so. Tests - 5 new unit tests in GenerationRefreshHostedServiceTests (first-apply, identity no-op, change-triggers-refresh, null-generation-is-no-op, lease-is-released-on-exit). Stub generation-query delegate; real coordinator backed by EF InMemory DB. - Server.Tests total 252 → 257. Docs - v2-release-readiness.md Phase 6.3 follow-ups list marks the sp_PublishGeneration lease wrap bullet struck-through with close-out note. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
de77d42eab |
Phase 6.3 Stream B — peer-probe HostedServices populating PeerReachabilityTracker
Closes task #116 (GA hardening backlog). Before this commit the RedundancyStatePublisher saw PeerReachability.Unknown for every peer because the tracker had no writers — every healthy peer got degraded to the Isolated-Primary band (230) even when fully reachable. Not release-blocking (safe default), but not the full non-transparent- redundancy UX either. Two-layer probe model per docs/v2/implementation/phase-6-3-redundancy-runtime.md §Stream B: - PeerHttpProbeLoop (Stream B.1) — fast-fail layer at 2 s / 1 s timeout. Hits each peer's http://{Host}:{DashboardPort}/healthz via an injected IHttpClientFactory. Writes the HTTP bit of PeerReachability while preserving the UA bit from the last UA probe so a transient HTTP blip doesn't clobber the authoritative UA reading. - PeerUaProbeLoop (Stream B.2) — authoritative layer at 10 s / 5 s timeout. Calls DiscoveryClient.GetEndpoints against opc.tcp://{Host}: {OpcUaPort} — cheap compared to a full Session.Create, no cert trust required. Short-circuits when the HTTP probe last reported the peer unhealthy (no wasted handshakes on a known-dead endpoint), clearing the stale UaHealthy bit in that case. Both inherit from BackgroundService, follow the tick/delay/catch pattern RedundancyPublisherHostedService + ResilienceStatusPublisherHostedService established, and expose TickAsync() as internal for test drive-through. New PeerProbeOptions class carries the four intervals/timeouts so operators can tune cadence per site. Registered as singleton in Program.cs; HTTP client registered by name so the OtOpcUa handler chain (Serilog enrichers, potential future OpenTelemetry instrumentation) isn't bypassed. Tests — 9 new unit tests across PeerHttpProbeLoopTests (5) and PeerUaProbeLoopTests (4). All pass. Server.Tests total 243 → 252. Full solution build clean. Docs: v2-release-readiness.md Phase 6.3 follow-ups list marks the peer-probe bullet struck-through with a close-out note. Still deferred in Phase 6.3: - OPC UA variable-node binding (task #117 — ServiceLevel + ServerUriArray) - sp_PublishGeneration lease wrap (task #118) - Client interop matrix (task #119) Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
96918b148c |
Unblock phase-6 compliance meta-runner on task-galaxy-e2e
Two small fixes so `scripts/compliance/phase-6-all.ps1` exits 0 — this is GA exit-criterion #1 from docs/v2/v2-release-readiness.md. 1. Admin csproj: bump OpenTelemetry.Extensions.Hosting 1.15.2 → 1.15.3 + OpenTelemetry.Exporter.Prometheus.AspNetCore 1.15.2-beta.1 → 1.15.3-beta.1. Fixes NU1902 moderate-severity advisory (GHSA-g94r-2vxg-569j) on the transitive OpenTelemetry.Api 1.15.2 pull. TreatWarningsAsErrors on the Admin project promoted the advisory to an error and failed the whole `dotnet test` run at restore. 2. SchemaComplianceTests.All_expected_tables_exist: the expected-tables list drifted behind four Phase 7 migration additions — Script, ScriptedAlarm, ScriptedAlarmState, VirtualTag. The EF model + live migrations have carried these tables for a while; the compliance test just needed the four names added. Applied migrations against a scratch DB to confirm the list is exhaustive. Verification: full solution test pass 2301 / 2301 (one tolerated pre-existing CLI flake). Phase 6 aggregate compliance: all four phases PASS with no test-count regression. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
69e0d02c72 |
task-galaxy-e2e branch — non-FOCAS work-in-progress snapshot
Catch-all commit for pending work on the task-galaxy-e2e branch that
wasn't part of the FOCAS migration. Grouping by topic so future per-topic
commits can be cherry-picked if needed.
TwinCAT
- src/.../Driver.TwinCAT/AdsTwinCATClient.cs + TwinCATDriverFactoryExtensions.cs:
factory-registration extensions + ADS client refinements.
- src/.../Driver.TwinCAT.Cli/Commands/BrowseCommand.cs: new browse command
for the TwinCAT test-client CLI.
- tests/.../Driver.TwinCAT.IntegrationTests/TwinCAT3SmokeTests.cs + TwinCatProject/:
fixture scaffold with a minimal POU + README pointing at the TCBSD/ESXi
VM for e2e.
- docs/Driver.TwinCAT.Cli.md + docs/drivers/TwinCAT-Test-Fixture.md:
documentation for the above.
- docs/v3/twincat-backlog.md: forward-looking backlog seed.
Admin UI + fleet status
- src/.../Admin/Components/Pages/Clusters/DriversTab.razor + Hosts.razor:
UI refresh for fleet-status rendering.
- src/.../Admin/Hubs/FleetStatusHub.cs + FleetStatusPoller.cs +
Admin/Program.cs: SignalR hub + poller plumbing for live fleet data.
- tests/.../Admin.Tests/FleetStatusPollerTests.cs: poller coverage.
Server + redundancy runtime (Phase 6.3 follow-ups)
- src/.../Server/Hosting/RedundancyPublisherHostedService.cs: HostedService
that owns the RedundancyStatePublisher lifecycle + wires peer reachability.
- src/.../Server/Redundancy/ServerRedundancyNodeWriter.cs: OPC UA
variable-node writer binding ServiceLevel + ServerUriArray to the
publisher's events.
- src/.../Server/Program.cs + Server.csproj: hosted-service registration.
- tests/.../Server.Tests/ServerRedundancyNodeWriterTests.cs +
Server.Tests.csproj: coverage for the above.
Configuration
- src/.../Configuration/Validation/DraftValidator.cs +
tests/.../Configuration.Tests/DraftValidatorTests.cs: draft-validation
refinements.
E2E scripts (shared infrastructure)
- scripts/e2e/README.md + _common.ps1 + test-all.ps1: shared helpers + the
all-drivers test-all runner.
- scripts/e2e/test-opcuaclient.ps1: OPC UA Client e2e runner.
Docs
- docs/v2/implementation/phase-6-{1,2,3,4}*.md + exit-gate-phase-{3,7}.md:
phase-gate + implementation doc updates.
- docs/v2/plan.md: top-level plan refresh.
- docs/v2/redundancy-interop-playbook.md: client interop playbook for the
Phase 6.3 redundancy-runtime work.
Two orphan FOCAS docs remain on disk but deliberately unstaged —
docs/v2/focas-deployment.md and docs/v2/implementation/focas-simulator-plan.md
describe the now-retired Tier-C topology and should either be rewritten
or deleted in a follow-up.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|
||
|
|
4b0664bd55 |
FOCAS — retire Tier-C split, inline managed wire client, make read-only
Migration closes the FOCAS Tier-C architecture. OtOpcUa previously had
`Driver.FOCAS.Host` (NSSM-wrapped Windows service loading Fwlib64.dll via
P/Invoke) + `Driver.FOCAS.Shared` (MessagePack IPC contracts) + a C shim
DLL stand-in for unit tests. All of it is deleted; the driver is now a
single in-process managed assembly talking the FOCAS/2 Ethernet binary
protocol directly on TCP:8193.
Architecture
- Pure-managed `FocasWireClient` inlined at `src/.../Driver.FOCAS/Wire/`
(owner-imported — see Wire/FocasWireClient.cs for the full surface).
Opens two TCP sockets, runs the initiate handshake, serialises requests
on socket 2 through a semaphore, closes cleanly with PDU + socket
teardown. Both sync `IDisposable` and async `IAsyncDisposable`.
- `WireFocasClient` (same folder) adapts the wire client to OtOpcUa's
`IFocasClient` surface — fixed-tree reads, PARAM/MACRO/PMC addresses,
alarms. Writes return `BadNotWritable` by design — OtOpcUa is read-only
against FOCAS.
- `FocasDriverFactoryExtensions` now accepts `"Backend": "wire"` (default)
and `"Backend": "unimplemented"`. Legacy `ipc` and `fwlib` backends are
rejected at startup with a diagnostic pointing at the migration doc.
Deletions
- `src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Host/` — whole project + Ipc/,
Backend/, Stability/, Program.cs.
- `src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Shared/` — Contracts/, FrameReader,
FrameWriter, whole project.
- `tests/...Driver.FOCAS.Host.Tests/` + `.Shared.Tests/` — whole projects.
- `src/.../Driver.FOCAS/FwlibNative.cs` + `FwlibFocasClient.cs` — 21
P/Invokes + 7 `Pack=1` marshalling structs + the Fwlib-backed
`IFocasClient` implementation.
- `src/.../Driver.FOCAS/Ipc/` + `Supervisor/` — IPC client wrapper +
Host-process supervisor (backoff, circuit breaker, heartbeat, post-
mortem reader, process launcher).
- `scripts/install/Install-FocasHost.ps1` — NSSM service installer.
- `tests/.../Driver.FOCAS.Tests/{IpcFocasClientTests, IpcLoopback,
FwlibNativeHelperTests, PostMortemReaderCompatibilityTests,
SupervisorTests, FocasDriverFactoryExtensionsTests}.cs` — tests that
exercised the retired surfaces.
- `tests/.../Driver.FOCAS.IntegrationTests/Shim/` — the zig-built C shim
DLL that masqueraded as Fwlib64.dll.
Solution changes
- `ZB.MOM.WW.OtOpcUa.slnx` drops the 4 retired project refs.
- `src/.../Driver.FOCAS.csproj` drops the Shared ProjectReference, adds
`Microsoft.Extensions.Logging.Abstractions` for the optional `ILogger`
hook in `FocasWireClient`.
- `src/.../Driver.FOCAS.Cli.csproj` drops the six `<Content Include>`
entries that copied `vendor/fanuc/*.dll` into the CLI bin. CLI now uses
`WireFocasClient` directly.
- `FocasDriver` default factory flips to `Wire.WireFocasClientFactory`.
Integration tests
- New `tests/.../Driver.FOCAS.IntegrationTests/` project covering fixed-
tree reads (identity, axes, dynamic, program, operation mode, timers,
spindle load + max RPM, servo meters), user-authored PARAM / MACRO /
PMC reads, `DiscoverAsync` emission, `SubscribeAsync` + `OnDataChange`,
`IAlarmSource` raise/clear transitions, and `ProbeAsync` /
`OnHostStatusChanged`. 9 e2e tests against the focas-mock fixture
(Docker container with the vendored Python mock's native FOCAS/2
Ethernet responder).
- `scripts/integration/run-focas.ps1` orchestrates compose up → tests →
compose down. Dropped the shim-build stage + DLL-copy step + the split
testhost workaround (the latter only existed because of native-DLL
lifecycle bugs the shim tripped).
- Docker compose collapses from 11 per-series services to one `focas-sim`
service. Tests seed per-series state via `mock_load_profile` at test
start.
- Vendored focas-mock snapshot refreshed to pick up upstream's native
FOCAS/2 Ethernet responder (was 660 lines, now 1018) — the
pre-refresh snapshot only spoke the JSON admin protocol.
Tests
- 145/145 unit tests in `Driver.FOCAS.Tests` pass (was 208 pre-deletion;
63 removed tests exercised the retired IPC/shim/supervisor/Fwlib
surfaces).
- 9/9 integration tests pass against the refreshed mock.
- `FocasScaffoldingTests.Unimplemented_factory_throws_on_Create…` updated
to assert the new diagnostic message pointing at
`docs/drivers/FOCAS.md` rather than the now-gone `Fwlib64.dll`.
Docs
- `docs/drivers/FOCAS.md` rewritten for the managed wire topology —
deployment collapses to one `"Backend": "wire"` config block, no
separate service, no DLL deployment, no pipe ACL.
- `docs/drivers/FOCAS-Test-Fixture.md` updated — single TCP probe skip
gate instead of TCP + shim probe; fewer moving parts.
- `docs/drivers/README.md` row for FOCAS reflects the Tier-A managed
topology (previously listed Tier-C + `Fwlib64.dll` P/Invoke).
- `docs/Driver.FOCAS.Cli.md` drops the Tier-C architecture-note section.
- `docs/v2/implementation/focas-isolation-plan.md` marked historical —
the plan it documents was executed then superseded by the wire client.
- `docs/v2/v2-release-readiness.md` re-audited 2026-04-24. Phase 5
driver complement closed. FOCAS change-log entry added.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|
||
|
|
404b54add0 |
FOCAS — commit previously-orphaned support files
Brings seven FOCAS-related files into git that shipped as part of earlier FOCAS work but were never staged. Adding them now so the tree reflects the compilable state + pre-empts dead references from the migration commit that follows: - src/.../Driver.FOCAS/FocasAlarmProjection.cs — raise/clear diffing + severity mapping surfaced via IAlarmSource on FocasDriver. Referenced by committed FocasDriver.cs; tests in FocasAlarmProjectionTests.cs. - src/.../Admin/Services/FocasDriverDetailService.cs — Admin UI per-instance detail page data source. - src/.../Admin/Components/Pages/Drivers/FocasDetail.razor — Blazor page rendering the above (from task #69). - tests/.../Admin.Tests/FocasDriverDetailServiceTests.cs — exercises the detail service. - tests/.../Driver.FOCAS.Tests/FocasAlarmProjectionTests.cs — raise/clear diff semantics against FakeFocasClient. - tests/.../Driver.FOCAS.Tests/FocasHandleRecycleTests.cs — proactive recycle cadence test. - docs/v2/implementation/focas-wire-protocol.md — captured FOCAS/2 Ethernet wire protocol reference. Useful going forward even though the Tier-C / simulator plan docs are historical. No runtime behaviour change — these files compile today and the solution build/test pass already depends on them. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
2ec6aa480e |
Task #219 — OpcUaServerOptions.AnonymousRoles (5/5 e2e stages pass)
Anonymous OPC UA sessions had no roles (`UserIdentity()`), so
`WriteAuthzPolicy.IsAllowed(SecurityClassification.Operate, [])`
rejected every write with `BadUserAccessDenied`. The reverse-write
stage of the Modbus e2e script surfaced this: stages 1-3 + 5 pass
forward-direction, stage 4 (OPC UA client → server → driver → PLC)
blew up with `0x801F0000` even with the factory + seed perfectly
wired.
Adds a single config knob:
"OpcUaServer": {
"AnonymousRoles": ["WriteOperate"]
}
Default empty preserves the pre-existing production-safe behaviour
(anonymous reads FreeAccess tags, rejected on everything else). When
non-empty, `OtOpcUaServer.OnImpersonateUser` wraps the anonymous token
in a `RoleBasedIdentity("(anonymous)", "Anonymous", AnonymousRoles)`
so the server-layer write guard sees the configured roles.
Wire-through:
- OpcUaServerOptions.AnonymousRoles (new)
- OpcUaApplicationHost passes it to OtOpcUaServer ctor
- OtOpcUaServer new anonymousRoles ctor param + OnImpersonateUser
branch
- Program.cs reads `OpcUaServer:AnonymousRoles` section from config
Env override syntax: `OpcUaServer__AnonymousRoles__0=WriteOperate`.
## Verified live
Booted server against `seed-modbus-smoke.sql` with
`OpcUaServer__AnonymousRoles__0=WriteOperate` + pymodbus fixture →
`test-modbus.ps1 -BridgeNodeId "ns=2;s=HR200"`:
=== Modbus e2e summary: 5/5 passed ===
[PASS] Probe
[PASS] Driver loopback
[PASS] Server bridge (driver → server → client)
[PASS] OPC UA write bridge (client → server → driver)
[PASS] Subscribe sees change
All five stages green end-to-end. Issue #219 closed by this PR; the
Modbus-seed update to set AnonymousRoles lives in the follow-up #220
live-boot PR (same AnonymousRoles value applies to every driver since
the classification is a driver-constant, not per-tag).
Full-solution build: 0 errors, only pre-existing xUnit1051 warnings.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|
||
|
|
7ba783de77 |
Tasks #211 #212 #213 — AbCip / S7 / AbLegacy server-side factories + seed SQL
Parent: #209. Follow-up to #210 (Modbus). Registers the remaining three non-Galaxy driver factories so a Config DB `DriverType` in {`AbCip`, `S7`, `AbLegacy`} actually boots a live driver instead of being silently skipped by DriverInstanceBootstrapper. Each factory follows the same shape as ModbusDriverFactoryExtensions + the existing Galaxy + FOCAS patterns: - Static `Register(DriverFactoryRegistry)` entry point. - Internal `CreateInstance(driverInstanceId, driverConfigJson)` — deserialises a DTO, strict-parses enum fields (fail-fast with an explicit "expected one of" list), composes the driver's options object, returns a new driver. - DriverType keys: `"AbCip"`, `"S7"`, `"AbLegacy"` (case-insensitive at the registry layer). DTO surfaces cover every option the respective driver's Options class exposes — devices, tags, probe, timeouts, per-driver quirks (AbCip `EnableControllerBrowse` / `EnableAlarmProjection`, S7 Rack/Slot/ CpuType, AbLegacy PlcFamily). Seed SQL (mirrors `seed-modbus-smoke.sql` shape): - `seed-abcip-smoke.sql` — `abcip-smoke` cluster + ControlLogix device + `TestDINT:DInt` tag, pointing at the ab_server compose fixture (`ab://127.0.0.1:44818/1,0`). - `seed-s7-smoke.sql` — `s7-smoke` cluster + S71500 CPU + `DB1.DBW0:Int16` tag at the python-snap7 fixture (`127.0.0.1:1102`, non-priv port). - `seed-ablegacy-smoke.sql` — `ablegacy-smoke` cluster + SLC 500 + `N7:5` tag. Hardware-gated per #222; placeholder gateway to be replaced with real SLC/MicroLogix/PLC-5/RSEmulate before running. Build plumbing: - Each driver project now ProjectReferences `Core` (was `Core.Abstractions`-only). `DriverFactoryRegistry` lives in `Core.Hosting` so the factory extensions can't compile without it. Matches the FOCAS + Galaxy.Proxy reference shape. - `Server.csproj` adds the three new driver ProjectReferences so Program.cs resolves the symbols at compile-time + ships the assemblies at runtime. Full-solution build: 0 errors, 334 pre-existing xUnit1051 warnings only. Live boot verification of all four (Modbus + these three) happens in the exit-gate PR — factories + seeds are pre-conditions and are being shipped first so the exit-gate PR can scope to "does the server publish the expected NodeIds + does the e2e script pass." Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
55245a962e |
Task #210 — Modbus server-side factory + seed SQL (closes first of #209 umbrella)
Parent: #209. Adds the server-side wiring so a Config DB `DriverType='Modbus'` row actually boots a Modbus driver instance + publishes its tags under OPC UA NodeIds, instead of being silently skipped by DriverInstanceBootstrapper. Changes: - `ModbusDriverFactoryExtensions` (new) — mirrors `GalaxyProxyDriverFactoryExtensions` + `FocasDriverFactoryExtensions`. `DriverTypeName="Modbus"`, `CreateInstance` deserialises `ModbusDriverConfigDto` (Host/Port/UnitId/TimeoutMs/Probe/Tags) to a full `ModbusDriverOptions` and hands back a `ModbusDriver`. Strict enum parsing (Region / DataType / ByteOrder / StringByteOrder) — unknown values fail fast with an explicit "expected one of" error rather than at first read. - `Program.cs` — register the factory after Galaxy + FOCAS. - `Driver.Modbus.csproj` — add `Core` project reference (the DI-free factory needs `DriverFactoryRegistry` from `Core.Hosting`). Matches the FOCAS driver's reference shape. - `Server.csproj` — add the `Driver.Modbus` ProjectReference so the Program.cs registration compiles against the same assembly the server loads at runtime. - `scripts/smoke/seed-modbus-smoke.sql` (new) — one-cluster smoke seed modelled on `seed-phase-7-smoke.sql`. Creates a `modbus-smoke` cluster + `modbus-smoke-node` + Draft generation + Namespace + UnsArea/UnsLine/ Equipment + one Modbus `DriverInstance` pointing at the pymodbus standard fixture (`127.0.0.1:5020`) + one Tag at `HR[200]:UInt16`, ending in `EXEC sp_PublishGeneration`. HR[100] is deliberately *not* used because pymodbus `standard.json` runs an auto-increment action on that register. Full-solution build: 0 errors, only the pre-existing xUnit1051 warnings. AB CIP / S7 / AB Legacy factories follow in their own PRs per #211 / #212 / #213. Live boot verification happens in the exit-gate PR once all four factories are in place. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
8d92e00e38 |
Task #253 — E2E CLI test scripts + FOCAS test-client CLI
The driver-layer integration tests confirm the driver sees the PLC, and
the Client.CLI tests confirm the client sees the server. Nothing glued
them end-to-end until this PR.
- scripts/e2e/_common.ps1: shared helpers — CLI invocation (published-
binary OR `dotnet run` fallback), Test-Probe / Test-DriverLoopback /
Test-ServerBridge (all return @{Passed;Reason} hashtables).
- scripts/e2e/test-<modbus|abcip|ablegacy|s7|focas|twincat>.ps1: per-
driver three-stage script (probe → driver-loopback → server-bridge).
AB Legacy / FOCAS / TwinCAT are gated behind *_TRUST_WIRE env vars
since they need real hardware (#222) or a licensed runtime (#221).
- scripts/e2e/test-phase7-virtualtags.ps1: writes a Modbus HR, reads
the server-side VirtualTag (VT = input * 2) back via OPC UA, triggers
+ clears a scripted alarm. Exercises the Phase 7 CachedTagUpstreamSource
+ ScriptedAlarmEngine path.
- scripts/e2e/test-all.ps1: reads e2e-config.json sidecar, runs each
present driver, prints a FINAL MATRIX (PASS/FAIL/SKIP). Missing
sections SKIP rather than fail hard.
- scripts/e2e/e2e-config.sample.json: commented sample — each dev's
NodeIds are local-seed-specific so e2e-config.json is .gitignore-d.
- scripts/e2e/README.md: full walkthrough — prereqs, three-stage design,
env-var gates, expected matrix, why this is separate from `dotnet test`.
Tasks #249-#251 shipped Modbus/AbCip/AbLegacy/S7/TwinCAT CLIs but left
FOCAS out. Since test-focas.ps1 needs it, the 6th CLI ships here:
- src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Cli: probe/read/write/subscribe
commands, AssemblyName `otopcua-focas-cli`. WriteCommand.ParseValue
handles the full FocasDataType enum (Bit/Byte/Int16/Int32/Float32/
Float64/String — no UInt variants; the FOCAS protocol exposes signed
PMC + Fanuc-Float only). Default DataType is Int16 to match the PMC
register convention.
Full-solution build clean (0 errors). FOCAS CLI wired into
ZB.MOM.WW.OtOpcUa.slnx. No .Tests project for the FOCAS CLI yet —
symmetric with how ProbeCommand has no unit-testable pure logic in the
other 5 CLIs either; WriteCommand.ParseValue parity will land in a
follow-up to keep this PR scoped.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|
||
|
|
4dc685a365 |
Task #251 — S7 + TwinCAT test-client CLIs (driver CLI suite complete)
Final two of the five driver test clients. Pattern carried forward from #249 (Modbus) + #250 (AB CIP, AB Legacy) — each CLI inherits Driver.Cli.Common for DriverCommandBase + SnapshotFormatter and adds a protocol-specific CommandBase + 4 commands (probe / read / write / subscribe). New projects: - src/ZB.MOM.WW.OtOpcUa.Driver.S7.Cli/ — otopcua-s7-cli. S7CommandBase carries host/port/cpu/rack/slot/timeout. Handles all S7 atomic types (Bool, Byte, Int16..UInt64, Float32/64, String, DateTime). DateTime parses via RoundtripKind so "2026-04-21T12:34:56Z" works. - src/ZB.MOM.WW.OtOpcUa.Driver.TwinCAT.Cli/ — otopcua-twincat-cli. TwinCATCommandBase carries ams-net-id + ams-port + --poll-only toggle (flips UseNativeNotifications=false). Covers the full IEC 61131-3 atomic set: Bool, SInt/USInt, Int/UInt, DInt/UDInt, LInt/ULInt, Real, LReal, String, WString, Time/Date/DateTime/TimeOfDay. Structure writes refused as out-of-scope (same as AB CIP). IEC time/date variants marshal as UDINT on the wire per IEC spec. Subscribe banner announces "ADS notification" vs "polling" so the mechanism is obvious in bug reports. Tests (49 new, 122 cumulative driver-CLI): - S7: 22 tests. Every S7DataType has a happy-path + bounds case. DateTime round-trips an ISO-8601 string. Tag-name synthesis round-trips every S7 address form (DB / M / I / Q, bit/word/dword, strings). - TwinCAT: 27 tests. Full IEC type matrix including WString UTF-8 pass- through + the four IEC time/date variants landing on UDINT. Structure rejection case. Tag-name synthesis for Program scope, GVL scope, nested UDT members, and array elements. Docs: - docs/Driver.S7.Cli.md — address grammar cheat sheet + the PUT/GET-must- be-enabled gotcha every S7-1200/1500 operator hits. - docs/Driver.TwinCAT.Cli.md — AMS router prerequisite (XAR / standalone Router NuGet / remote AMS route) + per-command examples. Wiring: - ZB.MOM.WW.OtOpcUa.slnx grew 4 entries (2 src + 2 tests). Full-solution build clean. Both --help outputs verified end-to-end. Driver CLI suite complete: 5 CLIs (otopcua-{modbus,abcip,ablegacy,s7,twincat}-cli) sharing a common base + formatter. 122 CLI tests cumulative. Every driver family shipped in v2 now has a shell-level ad-hoc validation tool. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
b2065f8730 |
Task #250 — AB CIP + AB Legacy test-client CLIs
Second + third of the four driver test clients. Both follow the same shape as otopcua-modbus-cli (#249) and consume Driver.Cli.Common for DriverCommandBase + SnapshotFormatter. New projects: - src/ZB.MOM.WW.OtOpcUa.Driver.AbCip.Cli/ — otopcua-abcip-cli. AbCipCommandBase carries gateway (ab://host[:port]/cip-path) + family (ControlLogix/CompactLogix/Micro800/GuardLogix) + timeout. Commands: probe, read, write, subscribe. Value parser covers every AbCipDataType atomic type (Bool, SInt..LInt, USInt..ULInt, Real, LReal, String, Dt); Structure writes refused as out-of-scope for the CLI. - src/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Cli/ — otopcua-ablegacy-cli. AbLegacyCommandBase carries gateway + plc-type (Slc500/MicroLogix/Plc5/ LogixPccc) + timeout. Commands: probe (default address N7:0), read, write, subscribe. Value parser covers Bit, Int, Long, Float, AnalogInt, String, and the three sub-element types (TimerElement / CounterElement / ControlElement all land on int32 at the wire). Tests (35 new, 73 cumulative across the driver CLI family): - AB CIP: 17 tests — ParseValue happy-paths for every Logix atomic type, failure cases (non-numeric / bool garbage), tag-name synthesis. - AB Legacy: 18 tests — ParseValue coverage (Bit / Int / AnalogInt / Long / Float / String / sub-elements), PCCC address round-trip in tag names including bit-within-word + sub-element syntax. Docs: - docs/Driver.AbCip.Cli.md — family ↔ CIP-path cheat sheet + examples per command + typical workflows. - docs/Driver.AbLegacy.Cli.md — PCCC address primer (file letters → CLI --type) + known ab_server upstream gap cross-ref to #224 close-out. Wiring: - ZB.MOM.WW.OtOpcUa.slnx grew 4 entries (2 src + 2 tests). Full-solution build clean. `otopcua-abcip-cli --help` + `otopcua-ablegacy-cli --help` verified end-to-end. Next up (#251): S7 + TwinCAT CLIs, same pattern. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
5dac2e9375 |
Task #249 — Driver test-client CLIs: shared lib + Modbus CLI first
Mirrors the v1 otopcua-cli value prop (ad-hoc shell-level PLC validation) for
the Modbus-TCP driver, and lays down the shared scaffolding that AB CIP, AB
Legacy, S7, and TwinCAT CLIs will build on.
New projects:
- src/ZB.MOM.WW.OtOpcUa.Driver.Cli.Common/ — DriverCommandBase (verbose
flag + Serilog config) + SnapshotFormatter (single-tag + table +
write-result renders with invariant-culture value formatting + OPC UA
status-code shortnames + UTC-normalised timestamps).
- src/ZB.MOM.WW.OtOpcUa.Driver.Modbus.Cli/ — otopcua-modbus-cli executable.
Commands: probe, read, write, subscribe. ModbusCommandBase carries the
host/port/unit-id flags + builds ModbusDriverOptions with Probe.Enabled
=false (CLI runs are one-shot; driver-internal keep-alive would race).
Commands + coverage:
- probe single FC03 + GetHealth() + pretty-print
- read region × address × type synth into one driver tag
- write same shape + --value parsed per --type
- subscribe polled-subscription stream until Ctrl+C
Tests (38 total):
- 16 SnapshotFormatterTests covering: status-code shortnames, unknown
codes fall back to hex, null value + timestamp placeholders, bool
lowercase, float invariant culture, string quoting, write-result shape,
aligned table columns, mismatched-length rejection, UTC normalisation.
- 22 Modbus CLI tests:
· ReadCommandTests.SynthesiseTagName (5 theory cases)
· WriteCommandParseValueTests (17 cases: bool aliases, unknown rejected,
Int16 bounds, UInt16/Bcd16 type, Float32/64 invariant culture,
String passthrough, BitInRegister, Int32 MinValue, non-numeric reject)
Wiring:
- ZB.MOM.WW.OtOpcUa.slnx grew 4 entries (2 src + 2 tests).
- docs/Driver.Modbus.Cli.md — operator-facing runbook with examples per
command + output format + typical workflows.
Regression: full-solution build clean; shared-lib tests 16/0, Modbus CLI tests
22/0.
Next up: repeat the pattern for AB CIP (shares ~40% more with Modbus via
libplctag), then AB Legacy, S7, TwinCAT. The shared base stays as-is unless
one of those exposes a gap the Modbus-first pass missed.
Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
|
||
|
|
dfe3731c73 |
Task #220 — Wire FOCAS into DriverFactoryRegistry bootstrap pipeline
Closes the non-hardware gap surfaced in the #220 audit: FOCAS had full Tier-C architecture (Driver.FOCAS + Driver.FOCAS.Host + Driver.FOCAS.Shared, supervisor, post-mortem MMF, NSSM scripts, 239 tests) but no factory registration, so config-DB DriverInstance rows of type "FOCAS" would fail at bootstrap with "unknown driver type". Hardware-gated FwlibHostedBackend (real Fwlib32 P/Invoke inside the Host process) stays deferred under #222 lab-rig. Ships: - FocasDriverFactoryExtensions.Register(registry) mirroring the Galaxy pattern. JSON schema selects backend via "Backend" field: "ipc" (default) — IpcFocasClientFactory → named-pipe FocasIpcClient → Driver.FOCAS.Host process (Tier-C isolation) "fwlib" — direct in-process FwlibFocasClientFactory (P/Invoke) "unimplemented" — UnimplementedFocasClientFactory (fail-fast on use — useful for staging DriverInstance rows pre-Host-deploy) - Devices / Tags / Probe / Timeout / Series feed into FocasDriverOptions. Series validated eagerly at top-level so typos fail at bootstrap, not first read. Tag DataType + Series enum values surface clear errors listing valid options. - Program.cs adds FocasDriverFactoryExtensions.Register alongside Galaxy. - Driver.FOCAS.csproj references Core (for DriverFactoryRegistry). - Server.csproj adds Driver.FOCAS ProjectReference so the factory type is reachable from Program.cs. Tests: 13 new FocasDriverFactoryExtensionsTests covering: registry entry, case-insensitive lookup, ipc backend with full config, ipc defaults, missing PipeName/SharedSecret errors, fwlib backend short-path, unimplemented backend, unknown-backend error, unknown-Series error, tag missing DataType, null/ws args, duplicate-register throws. Regression: 202 FOCAS + 13 FOCAS.Host + 24 FOCAS.Shared + 239 Server all pass. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
8221fac8c1 |
Task #219 follow-up — close AlarmConditionState child-NodeId + event-propagation gaps
PR #197 surfaced two integration-level wiring gaps in DriverNodeManager's MarkAsAlarmCondition path; this commit fixes both and upgrades the integration test to assert them end-to-end. Fix 1 — addressable child nodes: AlarmConditionState inherits ~50 typed children (Severity / Message / ActiveState / AckedState / EnabledState / …). The stack was leaving them with Foundation-namespace NodeIds (type-declaration defaults) or shared ns=0 counter allocations, so client Read on a child returned BadNodeIdUnknown. Pass assignNodeIds=true to alarm.Create, then walk the condition subtree and rewrite each descendant's NodeId symbolically as {condition-full-ref}.{symbolic-path} in the node manager's namespace. Stable, unique, and collision-free across multiple alarm instances in the same driver. Fix 2 — event propagation to Server.EventNotifier: OPC UA Part 9 event propagation relies on the alarm condition being reachable from Objects/Server via HasNotifier. Call CustomNodeManager2.AddRootNotifier(alarm) after registering the condition so subscriptions placed on Server-object EventNotifier receive the ReportEvent calls ConditionSink emits per-transition. Test upgrades in AlarmSubscribeIntegrationTests: - Driver_alarm_transition_updates_server_side_AlarmConditionState_node — now asserts Severity == 700, Message text, and ActiveState.Id == true through the OPC UA client (previously scoped out as BadNodeIdUnknown). - New: Driver_alarm_event_flows_to_client_subscription_on_Server_EventNotifier subscribes an OPC UA event monitor on ObjectIds.Server, fires a driver transition, and waits for the AlarmConditionType event to be delivered, asserting Message + Severity fields. Previously scoped out as "Part 9 event propagation out of reach." Regression checks: 239 server tests pass (+1 new event-subscription test), 195 Core tests pass. Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com> |
||
|
|
2cb22598d6 |
Drop accidentally-committed LiteDB cache file + add to .gitignore
The previous commit (#248 wiring) inadvertently picked up src/ZB.MOM.WW.OtOpcUa.Server/config_cache.db — generated by the live smoke re-run that proved the bootstrapper works. Remove from tracking + ignore going forward so future runs don't dirty the working tree. |
||
|
|
3d78033ea4 |
Driver-instance bootstrap pipeline (#248) — DriverInstance rows materialise as live IDriver instances
Closes the gap surfaced by Phase 7 live smoke (#240): DriverInstance rows in the central config DB had no path to materialise as live IDriver instances in DriverHost, so virtual-tag scripts read BadNodeIdUnknown for every tag. ## DriverFactoryRegistry (Core.Hosting) Process-singleton type-name → factory map. Each driver project's static Register call pre-loads its factory at Program.cs startup; the bootstrapper looks up by DriverInstance.DriverType + invokes with (DriverInstanceId, DriverConfig JSON). Case-insensitive; duplicate-type registration throws. ## GalaxyProxyDriverFactoryExtensions.Register (Driver.Galaxy.Proxy) Static helper — no Microsoft.Extensions.DependencyInjection dep, keeps the driver project free of DI machinery. Parses DriverConfig JSON for PipeName + SharedSecret + ConnectTimeoutMs. DriverInstanceId from the row wins over JSON per the schema's UX_DriverInstance_Generation_LogicalId. ## DriverInstanceBootstrapper (Server) After NodeBootstrap loads the published generation: queries DriverInstance rows scoped to that generation, looks up the factory per row, constructs + DriverHost.RegisterAsync (which calls InitializeAsync). Per plan decision #12 (driver isolation), failure of one driver doesn't prevent others — logs ERR + continues + returns the count actually registered. Unknown DriverType (factory not registered) logs WRN + skips so a missing-assembly deployment doesn't take down the whole server. ## Wired into OpcUaServerService.ExecuteAsync After NodeBootstrap.LoadCurrentGenerationAsync, before PopulateEquipmentContentAsync + Phase7Composer.PrepareAsync. The Phase 7 chain now sees a populated DriverHost so CachedTagUpstreamSource has an upstream feed. ## Live evidence on the dev box Re-ran the Phase 7 smoke from task #240. Pre-#248 vs post-#248: Equipment namespace snapshots loaded for 0/0 driver(s) ← before Equipment namespace snapshots loaded for 1/1 driver(s) ← after Galaxy.Host pipe ACL denied our SID (env-config issue documented in docs/ServiceHosting.md, NOT a code issue) — the bootstrapper logged it as "failed to initialize, driver state will reflect Faulted" and continued past the failure exactly per plan #12. The rest of the pipeline (Equipment walker + Phase 7 composer) ran to completion. ## Tests — 5 new DriverFactoryRegistryTests Register + TryGet round-trip, case-insensitive lookup, duplicate-type throws, null-arg guards, RegisteredTypes snapshot. Pure functions; no DI/DB needed. The bootstrapper's DB-query path is exercised by the live smoke (#240) which operators run before each release. |