#838(a): each notifier's SDK MonitoredNode2 drains a bounded channel (4096,
FullMode=Wait) and the synchronous NodeState.ReportEvent blocks when it is
full. Condition events are reported under Lock, and the delivery task takes
Lock on a verdict-cache miss (the SDK's own GetNodeMetadata, flag off too, and
#826's IsNotifierEventVisibleTo). A burst of >4096 events under one Lock hold
therefore deadlocked the node manager -- FolderEventFloodWireTests stalled at
exactly 4097 events with enforcement on AND off (so it predates #826).
ReportConditionEvent now goes through ReportEventWithoutBlocking:
ReportEventAsync completes inline while channels have room (unchanged normal
path); on overflow the report continues asynchronously holding no thread or
lock, and later reports queue behind it so events keep report order. The
deferred work holds only frozen snapshots and drains once Lock is released;
client delivery stays bounded by each item's queue.
#838(b): documented in docs/security.md that Part 3 ReceiveEvents applies to
the event's EventType and SourceNode (the SDK check, kept first), not to the
notifier; our decision is layered on top and non-condition events on a folder
item fail closed under enforcement. The reflection item stays open.
#844: a success cleared the whole per-client count, so a client holding a valid
key could make four guesses at another key id, sign in with its own, and repeat
forever. Failures are now charged to the (client, credential identity) pair --
IOpcUaUserAuthenticator.DescribeCredential, key:<keyId> for API keys -- and to
the client as a whole. A success clears only its own identity's count; the
per-identity threshold locks that identity; a new per-client cap
(OpcUa:CredentialLockout:MaxFailedAttemptsPerClient, default 2 x
MaxFailedAttempts) that a success never resets bounds spraying across key ids
and locks every credential. Slots are bounded on both counts; a waiter whose
identity has room is not held behind one whose identity has none.
#845: (1) store timeouts, miss-budget refusals, store/authenticator exceptions,
an unset pepper and cancellation are reported Transient
(OpcUaUserAuthResult.Unavailable) and released uncounted, so a ConfigDb stall
can no longer lock every keyed client out; the client still sees the same
opaque denial. (2) a full 4096-entry table defers its next prune until the
earliest entry could age out instead of rescanning under the lock per failure.
(3) ApplicationUri deliberately NOT added to the key: on a None channel it is a
free string, so it would let an attacker reset the count per guess --
documented. (4) wire tests: distinct client certificates on a Sign endpoint are
locked out separately; the ApplicationConfigPath branch keeps the SDK lockout
off (falsified by removing the loaded-branch disable).
A legitimate consumer opening several keyed sessions at once from one key
(e.g. a ScadaBridge site node behind one NAT IP on a None endpoint) must
never see BadUserAccessDenied for parallelism. BeginAsync now hands out at
most MaxFailedAttempts - recordedFailures verification slots per key;
further activations queue FIFO and are woken as slots free. A waiter is
refused only when the key locks out (never reaching the authenticator) or,
uncounted, after OpcUa:CredentialLockout:SlotWaitSeconds (default 10,
BadTimeout). Cancelled waiters are dequeued; pruning accounts for waiters.
The security property is unchanged: no more than MaxFailedAttempts
unverified guesses in progress-or-failed per window.
- Reserve an in-flight slot per client before authenticating (TryBegin /
Complete / Abandon under one lock); refuse once recorded failures +
in-flight attempts reach MaxFailedAttempts, so a parallel burst cannot
pass the check before its first failure is recorded.
- An expired lockout resets the count (LockoutSeconds < FailureWindowSeconds
relocked on every single failure after the first lockout).
- Validate OpcUa:CredentialLockout at host start: disabled, or both
durations > 0.
- Log the first refusal of a lockout episode at Information, the rest at
Debug.
- Document that on None endpoints the key is effectively IP-only (NAT
neighbours share a UserName count) and a null peer shares one key.
The proto comment, VirtualTags.md and CLAUDE.md said the soft deadline
measures the script's own execution and that starvation never counts. Only
the time before the run STARTS is excluded; from the start it is wall-clock
time, as in process, so a GC pause or a starved / suspended worker during
the run still counts. A mid-run freeze test is not added: it races the
script's own return against the watchdog's notice; documented as not covered.
Also documents F2 (late notice cancels and counts), F3 (progress ceiling,
killed_unresponsive) and F5 (answer = stalled | retrigger).
1. Orphaned subscriptions (session closed without deleting subs) have Session == null, so the public
MonitoredNode2.InvalidatePermissionCacheForSession never reached their items: a cached allow survived a
deploy, the moved alarm's events were queued and delivered on TransferSubscriptions. Each notifier's
cache is now cleared whole through the SDK's private MonitoredNode2.InvalidatePermissionCaches
(reflection, guard-tested; fallback = per-session drop + Remove/Add of session-less items).
2. The verdict is decided on the condition LIVE under the event's NodeId, not the event's own instance:
the SDK key has no instance identity, so a replaced instance's late event cached a deny its successor
inherited until the next invalidation.
3. Invalidation is skipped while enforcement is off (forced across an on/off authorizer transition) and is
one O(cache) clear per node instead of a whole-cache scan per item.
4. TagReferencingEquipment carries alarm-bearing raw tags only (TagConfigIntent.Alarm); the snapshot adopts
an OrdinalIgnoreCase set instead of copying it again.
Tests (each fails with its fix reverted): FolderEventVerdictInvalidationTests (orphan + deploy + transfer;
replaced instance's late event; ACL-off skip; SDK private-method guard), DeploymentArtifactScopePathTests
(alarm-bearing projection).
otopcua.script.ipc.timeouts gains the tag answer = stalled | retrigger: a
later trigger refused while the key's stalled run is still unanswered was
counted nowhere (not a script refusal, so not ScriptRunGuard's counter).
KeyState carries its Kind for the tag. Test: the stalled-worker test listens
for the instrument and sees one stalled and one retrigger (before: only
stalled).
With the worker soft clock the host's per-run timer is only the transport
deadline and the kill G is armed by the worker's soft notice, so a worker
whose watchdog never sends one (the design treats the worker as untrusted)
held the run, the key's slot and the tag's BadResourceUnavailable forever;
a deferred run had no host clock at all.
WorkerConnection now tracks evaluation progress (any Results frame, or the
submit that made the worker busy again). The heartbeat monitor kills the
worker when evaluations are outstanding and nothing progressed for
3 x the largest outstanding T + G plus the silence limit:
WorkerExitReason.KilledUnresponsive (metric reason killed_unresponsive), no
culprit, attributed like a heartbeat kill (suspects, no strike on a shard).
A legitimate run has answered or been killed by T + G.
Test seams: ProgressCeilingOverride, DropSoftNoticesForTest. Tests: a worker
whose notices are dropped (G = 60 s, so its own fail-fast cannot end it) is
killed KilledUnresponsive after the 1.5 s ceiling and the run is released
(with the check disabled the test times out); positive control: 20 queued
150 ms runs behind one thread under a 1 s ceiling are all answered.
F1: PendingEval.SoftExpired runs on the pipe reader and completed the
caller's outcome inline (production outcomes have no async continuations, by
design, because results resume on the ResultDispatcher). The caller's code
(the runner's Cancel write, the seam's publish) therefore ran on the reader,
which could hold up heartbeats (a false silence kill) and, with blocking I/O,
write to the pipe from the reader. The soft outcome is now posted to the
dispatcher like a result. Test: a 1.5 s continuation on a soft timeout with a
300 ms silence limit resumes on ScriptWorker[t].Results and the worker lives
(before: it resumed on the Reader).
F2: after a transport timeout ("worker unresponsive"), a late soft notice
armed G but nobody sent Cancel, so a polling script could not end itself and
the whole worker was killed at notice + G with a kill strike. PendingEval now
exposes LateSoftExpiry (asynchronous continuations, cancelled when the run
answers); the runner sends the Cancel and counts the timeout
(NoteTimeout) from it. A genuinely slow script whose notice is delayed past
T + G is thus still a timeout. Test: stall past T + G, thaw, a polling
script overruns T: the worker survives G and the key is quarantined for
timeouts, not a hard deadline (before: the worker was killed).
User decision: save, Test Connect, live browse and the deploy gate keep
refusing out-of-namespace credential references, but an ALREADY-DEPLOYED
driver must not fault at the upgrade restart or (Galaxy) at the next
gateway reconnect, since ReopenAsync re-resolves Gateway.ApiKeySecretRef.
- LegacyCredentialReferenceTracker (Core.Abstractions): the one, deprecated,
call-site-chosen compatibility path. Running Galaxy (InitializeAsync,
ReopenAsync, ack fallback) and OpcUaClient (session open) pass it and keep
the pre-#815 semantics (case-insensitive prefixes, Galaxy file:, OpcUaClient
literal pass-through) with a rate-limited Warning (driver/field/allowed
form, never the value) and a credential-compat:<field> diagnostics entry
(both drivers now implement IDriverDiagnostics). Browsers and probes pass
none and stay hard-fail; Heidenhain has none.
- Deploy-gate message names the migration.
- Upgrade preflight: CredentialReferencePreflightService (admin nodes, once
after ApplicationStarted, ConfigDb only, resolves nothing) logs a Warning
per Draft row / Deployed-artifact finding; the /raw banner shows them plus
Running drivers reporting warn-only use (driver-health diagnostics).
- docs/security.md: exact replacement table (incl. the old form default
env:MX_API_KEY, file:, un-namespaced secret:, casing changes), the
ReopenAsync reconnect behaviour, the warn-only window and its removal.
Co-Authored-By: Claude <noreply@anthropic.com>
A_burst_of_cold_compiles_does_not_starve_the_heartbeat (50 ms heartbeat) and
A_caller_that_blocks_after_its_result_does_not_starve_the_reader (100 ms)
launched their worker under the tight silence kill, so its cold start (launch,
first compile, Roslyn JIT) had to stay within 150/300 ms of silence. Under 28
busy processes on 14 cores that failed 2 in 10 runs in the WARM-UP, killed
for ~165 ms of silence, and replacement workers were killed the same way.
New test seam: WorkerLaunchSpec.HeartbeatSilenceLimit (runner internal ctor
heartbeatSilenceLimit) and WorkerConnection.SilenceLimit. The tests launch
with a 30 s limit, warm, then tighten to three intervals for the phase they
are about; the assertions on that phase are unchanged.
Event items on an equipment / raw device folder were fed by the SDK's MonitoredNode2 fan-out with no ACL
decision, so after a deploy moved a scripted alarm (or dropped the reference projecting a native alarm into
an equipment) the OLD folder's subscribers kept receiving it - EventId included - until the rebuild landed,
indefinitely after a failed apply.
- OtOpcUaNodeManager re-implements INodeManager3 so ValidateEventRolePermissions (the SDK's per-event,
per-item hook; base not virtual) adds IsNotifierEventVisibleTo: live condition instance, notifier still a
legitimate notifier of it, and the #586/#808 Server-object rule (IsConditionVisibleTo over
ConditionVisibilityScopes).
- The SDK memoizes that verdict per (item, event type, SourceNode): InvalidateFolderEventVerdicts runs on the
authority/authorizer setters, RevalidateMonitoredItems (deploy + timer) and CompleteAddressSpaceApply.
- ConditionRefresh on direct items goes through RefreshDirectItems (base loop + the same decision).
- New generation field TagReferencingEquipment (RawPath -> EquipmentIds, from the artifact's
UnsTagReferences via AclScopePathResolver.ResolveTagRawPath): a native alarm's wired equipment folder only
counts (folder delivery AND Server-object scopes) while the current generation still references it.
- Secondary #808 edge: UNS variables wired UNS->Raw Organizes by AddReference are tracked and always placed
as reference variables (an Area named like its equipment's id no longer narrows them).
Tests: UnsFolderScopeWireTests (moved alarm on a folder item + ConditionRefresh + rebuild; area named like
equipment id), NativeAlarmFolderEventAclWireTests (dropped reference: folder + Server object + refresh +
restore), DeploymentArtifactScopePathTests (projection). Rig/event tests now supply tag references.
The soft deadline T was armed on the host at submit, so the pipe round trip
and the time a starved worker waits to be scheduled counted against the
script: under load a trivial script reported 'script timed out', in Shadow
mode that was a script mismatch, and at T + G the host killed the worker and
struck the key.
- Protocol (additive, negotiated): Hello/Ready.worker_soft_clock and
EvalResults.soft_expired_eval_ids. protocol_version stays 1; a worker that
does not echo the flag keeps the pre-#827 host clock.
- Worker: the watchdog runs each run's soft clock from the moment an
evaluation thread starts it and reports the crossing (woken early for
budgets shorter than its 50 ms poll). It still never cancels by itself;
its fail-fast is anchored at the soft notice + G + margin.
- Host (PendingEval): the soft notice answers the caller and arms the kill G
later. The host's own timer becomes a transport deadline, T + G from submit
(restarted at a deferred run's start); passing it with no result and no
notice yields TransportTimedOut -> Unavailable 'script worker unresponsive'
(BadResourceUnavailable, recovery = the run's completion), no strike, no
kill, no Cancel. A re-trigger refused by that still-unanswered run is
Unavailable too, not 'previous run still running'. Counted as
otopcua.script.ipc.timeouts{kind}.
- Frame writer: coalescing now carries soft_expired_eval_ids (it silently
dropped them); the host processes soft notices before results in a frame.
- Shadow: unresponsive is shadow_unavailable (Unavailable), never a mismatch.
Tests: WorkerSoftClockTests suspends the real worker (SIGSTOP via libc kill /
NtSuspendProcess) - a stall past T still returns 7; a stall past T + G is a
runner fault with nothing struck; a late-starting runaway is still timed out
at T from its start and killed G after; Shadow stays match /
shadow_unavailable; both clocks enforce T and G; PendingEval state machine.
The test parks the removed child in PostStop (ShutdownGate) to hold the
retired-but-not-terminated window open, but PostStop abandons a shutdown after
DefaultShutdownTimeout (5 s). Under a loaded suite run more than 5 s can pass
between the stop and the host processing the stale burst; the child then
terminates, the host forgets it on Terminated, and the burst sent AS it is
forwarded and re-retained. Reproduced deterministically with a 6 s sleep
before the burst. Not a production path: a terminated actor cannot send.
DriverHostActor gains a childShutdownTimeout test seam (last parameter, passed
to DriverInstanceActor.Props). The test raises it to 5 min, asserts the child
was really stopped (ShutdownCount) before the burst, checks the premise as a
positive control (no Terminated by the time the fence has passed), and expects
Terminated once the gate is released. With an 8 s sleep before the burst the
fixed test passes.
- RawTagRowRules: the ONE driver-dispatched authority on Tag-ROW rules (access level /
Tag.DataType). RawTreeService's save path, the CSV import's staged review grid
(RawTagCsvMapper) and the manual-entry grid all call it; no call site names a driver.
A ReadWrite or mistyped Heidenhain row is now invalid IN THE PREVIEW instead of only at Commit.
- Manual-entry grid + tag modal: when the driver dictates the data type for the row's
address (RawTagRowDefaults.DictatedDataType), the field is a locked read-only value instead
of a select that commit silently replaced; the grid runs the row rule client-side and no
longer rewrites the row at commit.
- Driver/device modals: the credential refusal is shown once (the modal's save-gate notice);
HeidenhainDriverFormModel / HeidenhainDeviceModel.Validate report only ranges / endpoint.
- docs/drivers/Heidenhain.md: #831 alarm conditions + rediscovery, #830 authoring behaviour.
Tests: HeidenhainAuthoringUxTests (CSV preview == ImportTagsAsync row-for-row, dictated type
is what the save path accepts, single credential surface, ALARM: seeding, CSV alarm rows,
AlarmMs round-trip); HeidenhainAuthoringTests updated for the single-notice rule.
- ALARM: selectors (HeidenhainAlarmSelector, Contracts): ALARM:*, ALARM:OTHER,
ALARM:CLASS=<r>[/GROUP=<r>][/NUMBER=<r>] (<r> = n | lo..hi; negative numbers allowed).
An ALARM: address and the cross-driver alarm object only work together — the factory
refuses either alone, so editor, save path, CSV and deploy inspector agree. Data type
fixed Boolean; never a value (ReadAsync BadNotSupported), never in a data subscription.
- HeidenhainDriver implements IAlarmSource: one condition per ALARM: tag at its RawPath,
driven by the SAME allowlisted R_RI 27/28 walk on the control's single loop, on the new
Polling.AlarmMs cadence (default 2000 ms, only for controls carrying an ALARM: tag).
FOCAS #647 transition rules (Raise / Retrigger / Clear), identity = class+group+number+text,
deterministic display order, told-record on the driver instance, recorded only while a
handler listens. A failed walk (refusal, overflow, comms loss) is quality-only, never a clear.
- Acknowledge is LOCAL-ONLY: AcknowledgeAsync is a no-op success (FOCAS/MTConnect posture);
Lsv2ReadOnlyPolicy is unchanged — no ack or write request exists.
- Opt-in per tag, no driver flag (FOCAS #647 / MTConnect #626 precedent); Alarms/* arrays unchanged.
- IRediscoverable: a reconnect whose R_VR identity (model / NC / PLC / options) differs from
the previous session raises OnRediscoveryNeeded once (advisory re-browse chip). No extra traffic.
- AdminUI: Heidenhain joins NativeAlarmModel's alarm drivers; the typed editor fixes ALARM:
tags at Boolean and seeds/drops the alarm object with the selector; driver form gains
"Alarm conditions (ms)". (HeidenhainDriverFormModel also carries the #830 credential-notice change.)
Tests: HeidenhainAlarmTests (grammar, pairing, rules, simulator e2e with the captured iTNC 530
alarm record, local-only ack = zero bytes sent, quality-only outage/refusal, rediscovery),
Runtime.Tests HeidenhainNativeAlarmEndToEndTests (real DriverHostActor condition), a
DraftValidator case, and the NativeAlarmDriverSetGuard now scans the Heidenhain driver.
#816 finding: the SDK checks that the server certificate names the host only
when a session is created with checkDomain:true. The driver, the AdminUI
browser and Client.Shared all called the 8-argument
DefaultSessionFactory.CreateAsync, which forwards checkDomain:false — so no
host-name check ever ran (why a trusted NAT cert for *.invalid browsed fine
over an IP in #813). When enabled the SDK (Session.OpenAsync ->
ValidateDomains -> FindDomain) compares ConfiguredEndpoint.EndpointUrl.IdnHost
— the CONFIGURED host, because OpcUaEndpointSelection/EndpointSelector
rewrote the advertised one — against the cert's DNS/IP SANs; secured
sessions only, and the auto-accept handler accepts a mismatch.
Policy: certificateValidation.validateServerHostName, tri-state. Unset =
OpcUaCertificateValidationOptions.DefaultValidateServerHostName = false, the
pre-#816 behaviour, so nothing changes on upgrade; true = validate the
configured host; false = explicit NAT/port-publish opt-out. Threaded into the
driver, the AdminUI browser (same JSON) and the AdminUI form (a select that
keeps "unset" unset), Client.Shared ConnectionSettings.ValidateServerHostName
and the CLI --validate-host-name. A driver refusal names the opt-out.
#818: the NAT fixture's /app/pki is on the opc-plc-nat-pki volume (verified:
same thumbprint across --force-recreate), its PUBLIC cert is committed as
Docker/nat/opc-plc-nat-server.der, and NatPublishedEndpointBrowseTests run
every secure browse on a throwaway PKI (internal browser seam): refusal with
nothing trusted, positive with the cert trusted (unset/false host check), and
a BadCertificateHostNameInvalid refusal with the check on. The trusted cert is
OPCUA_NAT_SERVER_CERT or the committed one (skip on thumbprint mismatch);
OPCUA_NAT_SERVER_CERT_TRUSTED is retired. CI exports its throwaway NAT
container's public cert. ServerHostNameValidationTests pin the driver against
the plain opc-plc. MIN_EXECUTED not raised (needs a hosted run): +6 in
v2-integration (440 -> 446), documented in scripts/ci/README.md.
A Designer could point a Galaxy / OpcUaClient endpoint at a host they control,
set a credential field to any reference the node can resolve
(env:ConnectionStrings__ConfigDb, env:ServerHistorian__ApiKey, secret:<any>,
Galaxy file:<any path>) and click Test Connect / live browse; the node resolved
the value and sent it to that host.
One shared rule in Core.Abstractions (CredentialReferences +
DriverCredentialPolicy) generalises the #803 Heidenhain namespace:
- Galaxy: secret:galaxy/... | secret:otopcua/galaxy/... | env:OTOPCUA_GALAXY_... |
legacy env:GALAXY_MXGW_...; file: refused; dev:/literal API key unchanged.
- OpcUaClient: secret:opcuaclient/... | env:OTOPCUA_OPCUACLIENT_...; literals unchanged.
- Heidenhain adopts the shared parser/resolver (namespace unchanged).
Enforced at the AdminUI save path (DriverConfigSaveGate), the deploy gate
(CredentialReferenceDeployChecks, code CredentialReferenceOutOfScope), Test
Connect (AdminOperationsActor, before any probe), live browse
(BrowserSessionService, before any browser) and again at resolve time in every
driver/browser (fail closed, before any store/env read).
Co-Authored-By: Claude <noreply@anthropic.com>
#820: SqlServer + QuestDB now serve Part 13 DurationGood / DurationBad from the
same Good / Bad region totals TimeWeightedAggregator already computes for
PercentGood / PercentBad — reported in milliseconds (OPC UA Duration, the SDK's
unit), Uncertain time in neither (Mantis 0006166), same BadNoData / status /
Partial rules. AggregateFamilies.Served grows 17 -> 19, so i=11201 and the
up-front refusal follow automatically; Gateway still refuses both (explicit
served set, unchanged). Client.Shared AggregateType / mapper / CLI gain both.
The #796 oracle answers DurationGood through the Good-only subclass as well.
QualityMix conformance asserts both directly (Q and QP, hand values, ms, and
= PercentGood x interval), replaces the "refused up front" test, and adds
Duration* to the forward/reverse/truncated oracle comparisons.
#821 (facts only, no decision): SdkAggregateParityTests pins an Uncertain-first
late-start interval (QP over [0,20), both directions) against ours (Part 13
Total 163.96, TimeAverage 10.93), the frozen 1.5.378.182 calculators (188.96,
9.448), SDK 2.0.1's stock calculators (188.96, 9.448) and a Good-first control
(all 163.96); LiveAggregateLateStartFactsTests pins the same through the booted
server's runtime AggregateManager (live AggregateFilter) incl. DurationGood
15000 / PercentGood 75 there vs 8000 / 40 in HistoryRead (#809). QualityMix
adds the reverse late-start variant (reverse TW pin + reverse oracle windows).
Co-Authored-By: Claude <noreply@anthropic.com>
OPC Foundation SDK 2.0.1's SessionManager lockout refused EVERY
activation (Anonymous included, before the token is read) from a client
with 5 failed identity validations in 60 s, for 5 minutes, keyed on cert
thumbprint else peer IP. Disable it (MaxFailedAuthenticationAttempts=0
on built and loaded configs) and enforce FailedCredentialLockout in the
identity-registry adapter instead: UserName activations only, keyed on
thumbprint+peer together, same 5/60s/300s defaults, configurable via
OpcUa:CredentialLockout.
The shared RawConfirmDialog sat inside the Alarms tab branch, so Remove
reference (Tags) and Delete virtual tag (Virtual Tags) set it visible on
a page that did not render it. Pinned by brace depth in
DeleteConfirmationWiringTests.
The Test-Connect probe set is resolved inside the AdminOperations Akka starter; resolving
ISecretResolver there walks AddZbSecrets -> IAuditWriter -> ActorAuditWriter, whose ctor needs
AuditWriterActorKey (registered later in the same builder). Found by the docker-dev live gate.
Regression test: resolving the probe set never resolves ISecretResolver (fails before the fix).
Also: TagRowProblem doc comment re-attached; Heidenhain credential help text names the
secret:heidenhain/ and env:OTOPCUA_HEIDENHAIN_ namespaces.
- Review 1: RawTreeService Create/UpdateDriver and Create/UpdateDevice refuse a Heidenhain
config whose password fields are not blank / secret:heidenhain/... / env:OTOPCUA_HEIDENHAIN_...
(DriverConfigSaveGate over HeidenhainOptionsParser.DescribeCredentialProblems: top level,
Access, Devices[], case-insensitive keys; the value is never echoed), so a literal password
never reaches the draft DB. The driver and device modals show the reason and disable Save.
- Review 8: CreateTag/UpdateTag/ImportTags (tag modal, manual entry, CSV import, browse commit)
refuse a ReadWrite Heidenhain tag or a Tag.DataType that disagrees with what the driver
publishes (HeidenhainTagRules: catalog type, Float64 => Double, or the binding's dataType).
The tag modal and manual-entry grid fix the access level at Read and derive the data type from
the address (RawTagRowDefaults). New deploy gate HeidenhainTagDataTypeMismatch.
- docs/drivers/Heidenhain.md: credential namespace convention + why, the save-path and deploy
enforcement, optional-role credential behaviour, BadConfigurationError, backoff/ordering notes.
Tests: HeidenhainSavePathTests (service save path; red with the gates disabled) and new
DraftValidatorHeidenhainTests cases.
Review of af5c9744:
1. UNS reference variables (s=Area/Line/Equip/Eff) of a moved or renamed
equipment stayed readable/writable under the OLD names' grants: they now
resolve as ReferenceVariable and are authorized at their split path only
while it equals their live equipment folder's placement (live chain ==
generation chain) + one name; otherwise denied (Read and Write).
2. TryPlaceScriptedCondition now also requires the owner folder's live chain
to match the generation (AuthorizeScriptedCondition gains ownerFolderChain),
so a moved equipment's alarm/children/commands follow its folder.
3. Identifiers containing NUL are denied before the decision cache, keeping
client ids disjoint from the NUL-prefixed resolved-scope keys (a client
could otherwise poison a real folder's cached verdict for its key shard).
4. An id no live node holds is Unknown: placed at [\0unknown] so only
Cluster / Namespace-uns grants decide it (a removed opaque id can no longer
split onto a same-named narrow grant; narrow grantees get no NodeDeleted for
removed UNS folders/vtags/conditions — documented); 4-segment
reference-shaped ids keep their split.
5. A wire test drives placements from DeploymentArtifact.ParseDataPlaneAuthority.
Baseline updates: #797 owner tests (unit + wire) and Sdk2RepeatedAlarmAuthority
now install folder scopes; Sdk2HistoryAuthority's UNS alias used the RAW path
as its UNS id (never minted in production) and now carries EqA/HistoryAlias.
Each new guard was falsified (reverting it fails its test).
Real Heidenhain driver (factory-built from a merged config) against the in-process LSV2
simulator inside DriverInstanceActor: subscribe publishes Good, an OPC write is refused by
the runtime (no IWritable) with nothing sent to the control, an outage stamps
BadNoCommunication, recovery re-publishes the identical value Good, and only allowlisted
telegrams ever reach the simulated control.
UNS Area/Line/Equipment folders are minted under their opaque entity ids
(s=UA-/UL-/EQ-...), virtual tags under s=EQ-.../Name and scripted conditions
(+ #629 children) under s=<ScriptedAlarmId>[/...], while every UNS grant is
planted at a NAME path. DataPlaneAuthorizer split those ids, so with
Security:Acl:Enabled a narrow (Area/Line/Equipment) grant could not Browse,
Read, subscribe or HistoryRead them, and Server-object delivery never reached
it — so a narrow key never held the EventId Ack/Confirm/AddComment need.
- The generation carries UnsFolderScopes (folderId -> path + id chain), built
by DeploymentArtifact from the same AclScopePathResolver as the grants; ids
two entity kinds share are dropped; plumbed through IDataPlaneAuthoritySink.
- OtOpcUaNodeManager.ResolveUnsAclSubject reports live facts (folder id
ancestry / scripted owner binding); attached by the Authorizer setter.
- Evaluate places the subject against the CURRENT generation before the
decision cache, which now caches the walk keyed on the resolved scope.
Folders require live chain == generation chain (a moved equipment is denied
under old and new line until the rebuild). Owned nodes (vtags, conditions,
children) get owner path + a reserved segment, so Tag grants and their
Browse transit never expose them. Conditions share TryPlaceScriptedCondition
with the #797 command gate.
- Server-object visibility of a scripted condition is decided on the
condition alone, so a moved alarm cannot reach its old owner there.
Tests: UnsFolderScopeWireTests (opaque ids, end-to-end browse -> EventId ->
Acknowledge on an Equipment grant; sibling denied; Tag-only grant; moved alarm
and moved equipment stale windows). Rig tests now install folder scopes
explicitly (ServerEventRig.FolderScopes); the #797 recreate test deliberately
asserts the moved alarm is invisible to the Cluster observer in the window.
A wrong published value now reports its Success/Value/Reason/StatusCode, the
publish's wall time against the run budget, the run guard's in-flight /
refused / quarantined counters, thread-pool and GC state around the call,
the shadow stats, and the tails of the script and runner logs.
Reproduced under heavy load (32 `yes`, test at nice 20, load avg 300+):
3 of 8 runs failed, every one because the SIBLING's shadow run missed the
300 ms soft deadline in the starved worker ("shadow Failed [budget] script
timed out after 0.3s") and was rightly recorded as a sibling mismatch. No
published value was ever wrong. The out-of-process soft deadline is armed at
submit, so it covers the pipe round trip and worker scheduling too.
The run budget (which is also the worker's soft deadline) goes to the 2 s
production default; no assertion changes. The runaway still runs away and is
killed at T + HardGrace, so nothing the test proves depends on T being short.
Review of 3d1b86b4: OpcUaPublishActor installs a new authority generation
before applying its address space, and an apply that throws keeps the old one.
A scripted alarm moved from equipment A to B therefore stayed commandable with
A's grant under B's generation (briefly before the rebuild, or indefinitely
after a failed apply).
The generation now carries ScriptedAlarmOwners (ScriptedAlarmId -> EquipmentId,
decoded by ParseDataPlaneAuthority from the artifact's ScriptedAlarms rows, the
same rows the composition materialises from). AuthorizeScriptedCondition denies
unless the node manager's live binding names the same owner as the generation:
a moved alarm is denied under the old owner's, the new owner's and a Cluster
grant until the address space re-binds it; an alarm the generation no longer
deploys is denied. Install/apply order unchanged.
Tests: window (a) generation moved / binding stale => both owners and Cluster
denied, then rebuild under the new owner => new owner allowed, old denied;
window (b) apply failed after install => denied across clock and further
generations, then a successful rebuild restores the new owner only; undeployed
alarm denied; artifact decode of the owner map.
Scripted condition NodeIds are opaque ScriptedAlarmIds, so splitting them as a
topology path could never match an Equipment grant: a narrow equipment grant was
denied while a Cluster grant passed.
- OtOpcUaNodeManager binds each LIVE scripted condition instance to the
EquipmentId it was materialised under (only when it hangs under that folder);
dropped on remove / drop-recreate / equipment-subtree removal / rebuild; a
same-id re-materialise under another equipment re-parents and re-binds.
- DataPlaneAuthoritySnapshot carries EquipmentScopePaths (EquipmentId ->
[uns, Area, Line, Equipment]) decoded from the artifact by the same
AclScopePathResolver call that plants Equipment grants.
- DataPlaneAuthorizer.AuthorizeScriptedCondition re-reads key, grant and
generation per call (uncached) and evaluates at the owner path; unbound,
replaced or unplaceable owners deny under every grant. No id-split or
realm-root fallback.
- Native conditions (RawPath) and the ACL-off role gate are unchanged.
NodeIds and AlarmCommand.AlarmId are unchanged.
Sdk2OpaqueScriptedScopeBaselineTests deliberately flipped: it pinned the denial
and now pins owner-grant allow / sibling deny / cluster allow. Follow-up #808
(folder ids + Server-object event visibility for narrow UNS grants).
ShadowModeTests' runaway case asserted "slowest < 250 ms" around evaluations
whose timing included cold Roslyn compile/JIT of new script text, so it failed
on a healthy published path (540-880 ms measured, both SDK baselines).
The test now puts a test-owned barrier runner (GatedShadow) between the real
ShadowScriptRunner and the real worker pool. The runaway's first shadow run is
held before it reaches the pool, then (after it runs away in the worker, the
pool answers T and the worker is KilledDeadline with the runaway as culprit)
its outcome is held before comparison. Published evaluations made while a
barrier is closed must return the in-process values; a Mirror that waited for
its shadow hangs into a 30 s liveness failure (mutation-checked). Output
correctness, pool kill/quarantine, published-side never quarantined, the single
runaway mismatch (sibling is a victim, not compared) and key_busy drops are kept.
The wall-clock number moves to an opt-in Category=Perf case
(Shadow_published_path_latency_while_the_shadow_runs_away, OTOPCUA_SCRIPT_PERF=1)
on warmed evaluators, reporting hardware and load average.
Sibling: ContainmentTests' hard-deadline case timed the runaway's first
(cold-compile) run; it now compiles the runaway's source first with an input
that does not spin.