Commit Graph

549 Commits

Author SHA1 Message Date
Joseph Doherty
3c2c4f29ea Auto: focas-f1c — Modal codes + overrides
Closes #259

Adds Modal/ + Override/ fixed-tree subfolders per FOCAS device, mirroring the
pattern established by Status/ (#257) and Production/ (#258): cached snapshots
refreshed on the probe tick, served from cache on read, no extra wire traffic
on top of user-driven tag reads.

Modal/ surfaces the four universally-present aux modal codes M/S/T/B from
cnc_modal(type=100..103) as Int16. **G-group decoding (groups 1..21) is deferred
to a follow-up** — the FWLIB ODBMDL union differs per series + group and the
issue body explicitly permits this scoping. Adds the cnc_modal P/Invoke +
ODBMDL struct + a generic int16 cnc_rdparam helper so the follow-up can add
G-groups without further wire-level scaffolding.

Override/ surfaces Feed/Rapid/Spindle/Jog from cnc_rdparam at MTB-specific
parameter numbers (FocasDeviceOptions.OverrideParameters; defaults to 30i:
6010/6011/6014/6015). Per-field nullable params let a deployment hide overrides
their MTB doesn't wire up; passing OverrideParameters=null suppresses the entire
Override/ subfolder for that device.

6 unit tests cover discovery shape, omitted Override folder when unconfigured,
partial Override field selection, cached-snapshot reads (Modal + Override),
BadCommunicationError before first refresh, and the FwlibFocasClient
disconnected short-circuit.
2026-04-25 14:26:48 -04:00
ae7cc15178 Merge pull request '[focas] FOCAS — Parts count + cycle time' (#326) from auto/focas/F1-b into auto/driver-gaps 2026-04-25 14:17:17 -04:00
Joseph Doherty
3d9697b918 Auto: focas-f1b — parts count + cycle time
Closes #258
2026-04-25 14:14:54 -04:00
329e222aa2 Merge pull request '[focas] FOCAS — ODBST status flags as fixed-tree nodes' (#325) from auto/focas/F1-a into auto/driver-gaps 2026-04-25 14:07:42 -04:00
Joseph Doherty
551494d223 Auto: focas-f1a — ODBST status flags as fixed-tree nodes
Closes #257
2026-04-25 14:05:12 -04:00
5b4925e61a Merge pull request '[ablegacy] AbLegacy — Indirect/indexed addressing parser' (#324) from auto/ablegacy/4 into auto/driver-gaps 2026-04-25 13:53:28 -04:00
Joseph Doherty
4ff4cc5899 Auto: ablegacy-4 — indirect/indexed addressing parser
Closes #247
2026-04-25 13:51:03 -04:00
b95eaacc05 Merge pull request '[ablegacy] AbLegacy — Sub-element bit semantics' (#323) from auto/ablegacy/3 into auto/driver-gaps 2026-04-25 13:44:21 -04:00
Joseph Doherty
c89f5bb3b9 Auto: ablegacy-3 — sub-element bit semantics
Closes #246
2026-04-25 13:41:52 -04:00
07235d3b66 Merge pull request '[ablegacy] AbLegacy — MicroLogix function-file letters' (#322) from auto/ablegacy/2 into auto/driver-gaps 2026-04-25 13:34:46 -04:00
Joseph Doherty
f2bc36349e Auto: ablegacy-2 — MicroLogix function-file letters
Closes #245
2026-04-25 13:32:23 -04:00
ccf2e3a9c0 Merge pull request '[ablegacy] AbLegacy — PLC-5 octal I/O addressing' (#321) from auto/ablegacy/1 into auto/driver-gaps 2026-04-25 13:26:54 -04:00
Joseph Doherty
8f7265186d Auto: ablegacy-1 — PLC-5 octal I/O addressing
Closes #244
2026-04-25 13:25:22 -04:00
651d6c005c Merge pull request '[abcip] AbCip — CIP multi-tag write packing' (#320) from auto/abcip/1.4 into auto/driver-gaps 2026-04-25 13:16:49 -04:00
Joseph Doherty
36b2929780 Auto: abcip-1.4 — CIP multi-tag write packing
Group writes by device through new AbCipMultiWritePlanner; for families that
support CIP request packing (ControlLogix / CompactLogix / GuardLogix) the
packable writes for one device are dispatched concurrently so libplctag's
native scheduler can coalesce them onto one Multi-Service Packet (0x0A).
Micro800 keeps SupportsRequestPacking=false and falls back to per-tag
sequential writes. BOOL-within-DINT writes are excluded from packing and
continue to go through the per-parent RMW semaphore so two concurrent bit
writes against the same DINT cannot lose one another's update.

The libplctag .NET wrapper does not expose a Multi-Service Packet construction
API at the per-Tag surface (each Tag is one CIP service), so this PR uses
client-side coalescing — concurrent Task.WhenAll dispatch per device — rather
than building raw CIP frames. The native libplctag scheduler does pack
concurrent same-connection writes when the family allows it, which gives the
round-trip reduction #228 calls for without ballooning the diff.

Per-tag StatusCodes preserve caller order across success, transport failure,
non-writable tags, unknown references, and unknown devices, including in
mixed concurrent batches.

Closes #228
2026-04-25 13:14:28 -04:00
345ac97c43 Merge pull request '[abcip] AbCip — Array-slice read addressing Tag[0..N]' (#319) from auto/abcip/1.3 into auto/driver-gaps 2026-04-25 13:06:11 -04:00
Joseph Doherty
767ac4aec5 Auto: abcip-1.3 — array-slice read addressing
Closes #227
2026-04-25 13:03:45 -04:00
29edd835a3 Merge pull request '[abcip] AbCip — STRINGnn variant decoding' (#318) from auto/abcip/1.2 into auto/driver-gaps 2026-04-25 12:55:34 -04:00
Joseph Doherty
d78a471e90 Auto: abcip-1.2 — STRINGnn variant decoding
Closes #226

Adds nullable StringLength to AbCipTagDefinition + AbCipStructureMember
so STRING_20 / STRING_40 / STRING_80 UDT variants decode against the
right DATA-array capacity. The configured length threads through a new
StringMaxCapacity field on AbCipTagCreateParams and lands on the
libplctag Tag.StringMaxCapacity attribute (verified property on
libplctag 1.5.2). Null leaves libplctag's default 82-byte STRING in
place for back-compat. Driver gates on DataType == String so a stray
StringLength on a DINT tag doesn't reshape that buffer. UDT member
fan-out copies StringLength from the AbCipStructureMember onto the
synthesised member tag definition.

Tests: 4 new in AbCipDriverReadTests covering threaded StringMaxCapacity,
the null back-compat path, the non-String gate, and the UDT-member fan-out.
2026-04-25 12:53:20 -04:00
1d9e40236b Merge pull request '[abcip] AbCip — LINT/ULINT 64-bit fidelity' (#317) from auto/abcip/1.1 into auto/driver-gaps 2026-04-25 12:47:17 -04:00
Joseph Doherty
2e6228a243 Auto: abcip-1.1 — LINT/ULINT 64-bit fidelity
Closes #225
2026-04-25 12:44:43 -04:00
Joseph Doherty
21e0fdd4cd Docs audit — fill gaps so the top-level docs/ reference matches shipped code
Audit of docs/ against src/ surfaced shipped features without current-reference
coverage (FOCAS CLI, Core.Scripting+VirtualTags, Core.ScriptedAlarms,
Core.AlarmHistorian), an out-of-date driver count + capability matrix, ADR-002's
virtual-tag dispatch not reflected in data-path docs, broken cross-references,
and OpcUaServerReqs declaring OPC-020..022 that were never scoped. This commit
closes all of those so operators + integrators can stay inside docs/ without
falling back to v2/implementation/.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-23 09:42:42 -04:00
Joseph Doherty
5fc596a9a1 E2E test script — Galaxy (MXAccess) driver: read / write / subscribe / alarms / history
Seven-stage e2e script covering every Galaxy-specific capability surface:
IReadable + IWritable + ISubscribable + IAlarmSource + IHistoryProvider.
Unlike the other drivers there is no per-protocol CLI — Galaxy's proxy
lives in-process with the server + talks to OtOpcUaGalaxyHost over a
named pipe (MXAccess COM is 32-bit-only), so every stage runs through
`otopcua-cli` against the published OPC UA address space.

## Stages

1. Probe                   — otopcua-cli read on the source NodeId
2. Source read             — capture value for downstream comparison
3. Virtual-tag bridge      — Phase 7 VirtualTag (source × 2) through
                             CachedTagUpstreamSource
4. Subscribe-sees-change   — data-change events propagate
5. Reverse bridge          — opc-ua write → Galaxy; soft-passes if the
                             attribute's Galaxy-side ACL forbids writes
                             (`BadUserAccessDenied` / `BadNotWritable`)
6. Alarm fires             — scripted-alarm Condition fires with Active
                             state when source crosses threshold
7. History read            — historyread returns samples from the Aveva
                             Historian → IHistoryProvider path

## Two new helpers in _common.ps1

- `Test-AlarmFiresOnThreshold` — start `otopcua-cli alarms --refresh`
  in the background on a Condition NodeId, drive the source change,
  assert captured stdout contains `ALARM` + `Active`. Uses the same
  Start-Process + temp-file pattern as `Test-SubscribeSeesChange` since
  the alarms command runs until Ctrl+C (no built-in --duration).
- `Test-HistoryHasSamples` — call `otopcua-cli historyread` over a
  configurable lookback window, parse `N values returned.` marker, fail
  if below MinSamples. Works for driver-sourced, virtual, or scripted-
  alarm historized nodes.

## Wiring

- `test-all.ps1` picks up the optional `galaxy` sidecar section and
  runs the script with the configured NodeIds + wait windows.
- `e2e-config.sample.json` adds a `galaxy` section seeded with the
  Phase 7 defaults (`p7-smoke-tag-source` / `-vt-derived` /
  `-al-overtemp`) — matches `scripts/smoke/seed-phase-7-smoke.sql`.
- `scripts/e2e/README.md` expected-matrix gains a Galaxy row.

## Prereqs

- OtOpcUaGalaxyHost running (NSSM-wrapped) with the Galaxy + MXAccess
  runtime available
- `seed-phase-7-smoke.sql` applied with a live Galaxy attribute
  substituted into `dbo.Tag.TagConfig`
- OtOpcUa server running against the `p7-smoke` cluster
- Non-elevated shell (Galaxy.Host pipe ACL denies Admins)

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 12:59:06 -04:00
05d2a7fd00 Merge pull request 'Task #222 partial — unblock AB Legacy PCCC via cip-path workaround (5/5 stages)' (#223) from task-222-ablegacy-pccc-unblock into v2 2026-04-21 12:52:59 -04:00
Joseph Doherty
95c7e0b490 Task #222 partial — unblock AB Legacy PCCC via cip-path workaround (5/5 stages)
Replaced the "ab_server PCCC upstream-broken" skip gate with the actual
root cause: libplctag's ab_server rejects empty CIP routing paths at the
unconnected-send layer before the PCCC dispatcher runs. Real SLC/
MicroLogix/PLC-5 hardware accepts empty paths (no backplane); ab_server
does not. With `/1,0` in place, N (Int16), F (Float32), and L (Int32)
file reads + writes round-trip cleanly across all three compose profiles.

## Fixture changes

- `AbLegacyServerFixture.cs`:
  - Drop `AB_LEGACY_TRUST_WIRE` env var + the reachable-but-untrusted
    skip branch. Fixture now only skips on TCP unreachability.
  - Add `AB_LEGACY_CIP_PATH` env var (default `1,0`) + expose `CipPath`
    property. Set `AB_LEGACY_CIP_PATH=` (empty) against real hardware.
  - Shorter skip messages on the `[AbLegacyFact]` / `[AbLegacyTheory]`
    attributes — one reason: endpoint not reachable.

- `AbLegacyReadSmokeTests.cs`:
  - Device URI built from `sim.CipPath` instead of hardcoded empty path.
  - New `AB_LEGACY_COMPOSE_PROFILE` env var filters the parametric
    theory to the running container's family. Only one container binds
    `:44818` at a time, so cross-family params would otherwise fail.
  - `Slc500_write_then_read_round_trip` skips cleanly when the running
    profile isn't `slc500`.

## E2E + seed + docs

- `scripts/e2e/test-ablegacy.ps1` — drop the `AB_LEGACY_TRUST_WIRE`
  skip gate; synopsis calls out the `/1,0` vs empty cip-path split
  between the Docker fixture and real hardware.
- `scripts/e2e/e2e-config.sample.json` — sample gateway flipped from
  the hardware placeholder (`192.168.1.10`) to the Docker fixture
  (`127.0.0.1/1,0`); comment rewritten.
- `scripts/e2e/README.md` — AB Legacy expected-matrix row goes from
  SKIP to PASS.
- `scripts/smoke/seed-ablegacy-smoke.sql` — default HostAddress points
  at the Docker fixture + header / footer text reflect the new state.
- `tests/.../Docker/README.md` — "Known limitations" section rewritten
  to describe the cip-path gate (not a dispatcher gap); env-var table
  picks up `AB_LEGACY_CIP_PATH` + `AB_LEGACY_COMPOSE_PROFILE`.
- `docs/drivers/AbLegacy-Test-Fixture.md` + `docs/drivers/README.md`
  + `docs/DriverClis.md` — flip status from blocked to functional;
  residual bit-file-write gap (B3:0/5 → 0x803D0000) documented.

## Residual gap

Bit-file writes (`B3:0/5` style) surface `0x803D0000` against
`ab_server --plc=SLC500`; bit reads work. Non-blocking for smoke
coverage — N/F/L round-trip is enough. Real hardware / RSEmulate 500
for bit-write fidelity. Documented in `Docker/README.md` §"Known
limitations" + the `AbLegacy-Test-Fixture.md` follow-ups list.

## Verified

- Full-solution build: 0 errors, 334 pre-existing warnings.
- Integration suite passes per-profile with
  `AB_LEGACY_COMPOSE_PROFILE=<slc500|micrologix|plc5>` + matching
  compose container up.
- All four non-hardware e2e scripts (Modbus / AB CIP / AB Legacy / S7)
  now 5/5 against the respective docker-compose fixtures.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 12:38:43 -04:00
e1f172c053 Merge pull request 'Task #220 — AB CIP + S7 live-boot verification (5/5 stages each)' (#222) from task-220-exitgate-abcip-s7 into v2 2026-04-21 12:04:51 -04:00
Joseph Doherty
6d290adb37 Task #220 — AB CIP + S7 live-boot verification (5/5 stages each)
Replicated the Modbus #218 bring-up against the AB CIP + S7 seeds to
confirm the factories + seeds shipped in #217 actually work end-to-end.
Both pass 5/5 e2e stages with `OpcUaServer:AnonymousRoles=[WriteOperate]`
(the #221 knob).

## AB CIP (against ab_server controllogix fixture, port 44818)

```
=== AB CIP e2e summary: 5/5 passed ===
[PASS] Probe
[PASS] Driver loopback
[PASS] Server bridge           (driver → server → client)
[PASS] OPC UA write bridge     (client → server → driver)
[PASS] Subscribe sees change
```

Server log: `DriverInstance abcip-smoke-drv (AbCip) registered +
initialized` ✓.

## S7 (against python-snap7 s7_1500 fixture, port 1102)

```
=== S7 e2e summary: 5/5 passed ===
[PASS] Probe
[PASS] Driver loopback
[PASS] Server bridge
[PASS] OPC UA write bridge
[PASS] Subscribe sees change
```

Server log: `DriverInstance s7-smoke-drv (S7) registered + initialized` ✓.

## Seed fixes so bring-up is idempotent

Live-boot exposed two seed-level papercuts when applying multiple
smoke seeds in sequence:

1. **SA credential collision.** `UX_ClusterNodeCredential_Value` is a
   unique index on `(Kind, Value) WHERE Enabled=1`, so `sa` can only
   bind to one node at a time. Each seed's DELETE block only dropped
   the credential tied to ITS node — seeding AbCip after Modbus blew
   up with `Cannot insert duplicate key` on the sa binding. Added a
   global `DELETE FROM dbo.ClusterNodeCredential WHERE Kind='SqlLogin'
   AND Value='sa'` before the per-cluster INSERTs. Production deployments
   using non-SA logins aren't affected.

2. **DashboardPort 5000 → 15050.** `HealthEndpointsHost` uses
   `HttpListener`, which rejects port 5000 on Windows without a
   `netsh http add urlacl` grant or admin rights. 15050 is unreserved
   + loopback-safe per the HealthEndpointsHost remarks. Applied to all
   four smoke seeds (Modbus was patched at runtime in #218; now baked
   into the seed).

## AB Legacy status

Not live-boot verified — ab_server PCCC dispatcher is upstream-broken
(#222). The factory + seed ship ready for hardware; the seed's DELETE
+ DashboardPort fixes land in this PR so when real SLC/MicroLogix/PLC-5
arrives the sql just applies.

## Closes #220

Umbrella #209 was already closed; #220 was the final child.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 12:02:40 -04:00
cc8a6c9ec1 Merge pull request 'Task #219 — OpcUaServerOptions.AnonymousRoles (5/5 e2e stages pass)' (#221) from task-219-anonymous-roles into v2 2026-04-21 11:51:56 -04:00
Joseph Doherty
2ec6aa480e Task #219 — OpcUaServerOptions.AnonymousRoles (5/5 e2e stages pass)
Anonymous OPC UA sessions had no roles (`UserIdentity()`), so
`WriteAuthzPolicy.IsAllowed(SecurityClassification.Operate, [])`
rejected every write with `BadUserAccessDenied`. The reverse-write
stage of the Modbus e2e script surfaced this: stages 1-3 + 5 pass
forward-direction, stage 4 (OPC UA client → server → driver → PLC)
blew up with `0x801F0000` even with the factory + seed perfectly
wired.

Adds a single config knob:

    "OpcUaServer": {
      "AnonymousRoles": ["WriteOperate"]
    }

Default empty preserves the pre-existing production-safe behaviour
(anonymous reads FreeAccess tags, rejected on everything else). When
non-empty, `OtOpcUaServer.OnImpersonateUser` wraps the anonymous token
in a `RoleBasedIdentity("(anonymous)", "Anonymous", AnonymousRoles)`
so the server-layer write guard sees the configured roles.

Wire-through:
 - OpcUaServerOptions.AnonymousRoles (new)
 - OpcUaApplicationHost passes it to OtOpcUaServer ctor
 - OtOpcUaServer new anonymousRoles ctor param + OnImpersonateUser
   branch
 - Program.cs reads `OpcUaServer:AnonymousRoles` section from config

Env override syntax: `OpcUaServer__AnonymousRoles__0=WriteOperate`.

## Verified live

Booted server against `seed-modbus-smoke.sql` with
`OpcUaServer__AnonymousRoles__0=WriteOperate` + pymodbus fixture →
`test-modbus.ps1 -BridgeNodeId "ns=2;s=HR200"`:

    === Modbus e2e summary: 5/5 passed ===
    [PASS] Probe
    [PASS] Driver loopback
    [PASS] Server bridge            (driver → server → client)
    [PASS] OPC UA write bridge      (client → server → driver)
    [PASS] Subscribe sees change

All five stages green end-to-end. Issue #219 closed by this PR; the
Modbus-seed update to set AnonymousRoles lives in the follow-up #220
live-boot PR (same AnonymousRoles value applies to every driver since
the classification is a driver-constant, not per-tag).

Full-solution build: 0 errors, only pre-existing xUnit1051 warnings.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 11:49:41 -04:00
682c1c5e75 Merge pull request 'Task #209 exit gate — seed-creds fix + live Modbus verification (4/5 stages)' (#218) from task-209-exitgate-seed-creds into v2 2026-04-21 11:32:22 -04:00
Joseph Doherty
e8172f9452 Task #209 exit gate — seed-creds fix + live Modbus verification (4/5 stages)
Booted the server against the Modbus seed end-to-end to exercise the
factory wiring shipped in #216 + #217. Surfaced two real issues with
the seeds themselves; fixed both:

1. **Missing ClusterNodeCredential.** `sp_GetCurrentGenerationForCluster`
   enforces `ClusterNodeCredential.Value = SUSER_SNAME()` and aborts
   with `RAISERROR('Unauthorized: caller sa is not bound to NodeId')`.
   All four seed scripts now insert the binding row alongside the
   ClusterNode row. Without this, the server fails bootstrap with
   `BootstrapException: Central DB unreachable and no local cache
   available` (the Unauthorized error gets swallowed on top of the
   HTTP fallback path).

2. **Config cache gitignore.** Running the server from the repo root
   writes `config_cache.db` + `config_cache-log.db` next to the cwd,
   outside the existing `src/.../Server/config_cache.db` pattern. Add
   a `config_cache*.db` pattern so any future run location is covered.

## Verified live against Modbus

Booted server against `seed-modbus-smoke.sql` → pymodbus standard
fixture → ran `scripts/e2e/test-modbus.ps1 -BridgeNodeId "ns=2;s=HR200"`:

    === Modbus e2e summary: 4/5 passed ===
    [PASS] Probe
    [PASS] Driver loopback
    [PASS] Server bridge (driver → server → client)
    [FAIL] OPC UA write bridge (0x801F0000)
    [PASS] Subscribe sees change

The forward direction + subscription delivery are proven working through
the server. The reverse-write failure is a seed-or-ACL issue — server
log shows no exception on the write path, so the client-side status is
coming from the stack's type/ACL guards. Tracking as a follow-up issue
so the remaining three factory wirings can be smoke-booted against the
same pattern.

Note for future runs: two stale v1 `ZB.MOM.WW.LmxOpcUa.Host.exe`
processes from `C:\publish\lmxopcua\instance{1,2}\` squat on ports
4840 + 4841 on this dev box; kill them first or bump the seed's
DashboardPort.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 11:30:00 -04:00
3af746c4b6 Merge pull request 'Tasks #211 #212 #213 — AbCip / S7 / AbLegacy server-side factories + seed SQL' (#217) from task-211-212-213-factories into v2 2026-04-21 11:17:47 -04:00
Joseph Doherty
7ba783de77 Tasks #211 #212 #213 — AbCip / S7 / AbLegacy server-side factories + seed SQL
Parent: #209. Follow-up to #210 (Modbus). Registers the remaining three
non-Galaxy driver factories so a Config DB `DriverType` in
{`AbCip`, `S7`, `AbLegacy`} actually boots a live driver instead of
being silently skipped by DriverInstanceBootstrapper.

Each factory follows the same shape as ModbusDriverFactoryExtensions +
the existing Galaxy + FOCAS patterns:
 - Static `Register(DriverFactoryRegistry)` entry point.
 - Internal `CreateInstance(driverInstanceId, driverConfigJson)` —
   deserialises a DTO, strict-parses enum fields (fail-fast with an
   explicit "expected one of" list), composes the driver's options object,
   returns a new driver.
 - DriverType keys: `"AbCip"`, `"S7"`, `"AbLegacy"` (case-insensitive at
   the registry layer).

DTO surfaces cover every option the respective driver's Options class
exposes — devices, tags, probe, timeouts, per-driver quirks
(AbCip `EnableControllerBrowse` / `EnableAlarmProjection`, S7 Rack/Slot/
CpuType, AbLegacy PlcFamily).

Seed SQL (mirrors `seed-modbus-smoke.sql` shape):
 - `seed-abcip-smoke.sql` — `abcip-smoke` cluster + ControlLogix device +
   `TestDINT:DInt` tag, pointing at the ab_server compose fixture
   (`ab://127.0.0.1:44818/1,0`).
 - `seed-s7-smoke.sql` — `s7-smoke` cluster + S71500 CPU + `DB1.DBW0:Int16`
   tag at the python-snap7 fixture (`127.0.0.1:1102`, non-priv port).
 - `seed-ablegacy-smoke.sql` — `ablegacy-smoke` cluster + SLC 500 + `N7:5`
   tag. Hardware-gated per #222; placeholder gateway to be replaced with
   real SLC/MicroLogix/PLC-5/RSEmulate before running.

Build plumbing:
 - Each driver project now ProjectReferences `Core` (was
   `Core.Abstractions`-only). `DriverFactoryRegistry` lives in `Core.Hosting`
   so the factory extensions can't compile without it. Matches the FOCAS +
   Galaxy.Proxy reference shape.
 - `Server.csproj` adds the three new driver ProjectReferences so Program.cs
   resolves the symbols at compile-time + ships the assemblies at runtime.

Full-solution build: 0 errors, 334 pre-existing xUnit1051 warnings only.

Live boot verification of all four (Modbus + these three) happens in the
exit-gate PR — factories + seeds are pre-conditions and are being
shipped first so the exit-gate PR can scope to "does the server publish
the expected NodeIds + does the e2e script pass."

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 11:15:38 -04:00
35d24c2f80 Merge pull request 'Task #210 — Modbus server-side factory + seed SQL' (#216) from task-210-modbus-factory-seed into v2 2026-04-21 11:08:20 -04:00
Joseph Doherty
55245a962e Task #210 — Modbus server-side factory + seed SQL (closes first of #209 umbrella)
Parent: #209. Adds the server-side wiring so a Config DB `DriverType='Modbus'`
row actually boots a Modbus driver instance + publishes its tags under OPC UA
NodeIds, instead of being silently skipped by DriverInstanceBootstrapper.

Changes:
 - `ModbusDriverFactoryExtensions` (new) — mirrors
   `GalaxyProxyDriverFactoryExtensions` + `FocasDriverFactoryExtensions`.
   `DriverTypeName="Modbus"`, `CreateInstance` deserialises
   `ModbusDriverConfigDto` (Host/Port/UnitId/TimeoutMs/Probe/Tags) to a full
   `ModbusDriverOptions` and hands back a `ModbusDriver`. Strict enum parsing
   (Region / DataType / ByteOrder / StringByteOrder) — unknown values fail
   fast with an explicit "expected one of" error rather than at first read.
 - `Program.cs` — register the factory after Galaxy + FOCAS.
 - `Driver.Modbus.csproj` — add `Core` project reference (the DI-free factory
   needs `DriverFactoryRegistry` from `Core.Hosting`). Matches the FOCAS
   driver's reference shape.
 - `Server.csproj` — add the `Driver.Modbus` ProjectReference so the
   Program.cs registration compiles against the same assembly the server
   loads at runtime.
 - `scripts/smoke/seed-modbus-smoke.sql` (new) — one-cluster smoke seed
   modelled on `seed-phase-7-smoke.sql`. Creates a `modbus-smoke` cluster +
   `modbus-smoke-node` + Draft generation + Namespace + UnsArea/UnsLine/
   Equipment + one Modbus `DriverInstance` pointing at the pymodbus standard
   fixture (`127.0.0.1:5020`) + one Tag at `HR[200]:UInt16`, ending in
   `EXEC sp_PublishGeneration`. HR[100] is deliberately *not* used because
   pymodbus `standard.json` runs an auto-increment action on that register.

Full-solution build: 0 errors, only the pre-existing xUnit1051 warnings.

AB CIP / S7 / AB Legacy factories follow in their own PRs per #211 / #212 /
#213. Live boot verification happens in the exit-gate PR once all four
factories are in place.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 11:06:08 -04:00
16d9592a8a Merge pull request 'Task #253 follow-up — fix test-all.ps1 StrictMode crash on missing JSON keys' (#215) from task-253d-e2e-debug-harness into v2 2026-04-21 10:57:34 -04:00
Joseph Doherty
2666a598ae Task #253 follow-up — fix test-all.ps1 StrictMode crash on missing JSON keys
Running `test-all.ps1` end-to-end with a partial sidecar (only modbus/
abcip/s7 populated, no focas/twincat/phase7) crashed:

    [FAIL] modbus runner crashed: The property 'opcUaUrl' cannot be
    found on this object. Verify that the property exists.

Root cause: `_common.ps1` sets `Set-StrictMode -Version 3.0`, which
turns missing-property access on PSCustomObject into a throw. Every
`$config.<driver>.<optional-field> ?? $default` and `if
($config.<missing-section>)` check is therefore unsafe against a
normal JSON where optional fields are omitted.

Fix: switch to `ConvertFrom-Json -AsHashtable` and add a `Get-Or`
helper. Hashtables tolerate `.ContainsKey()` / indexer access even
under StrictMode, so the per-driver sections now read:

    $modbus = Get-Or $config "modbus"
    if ($modbus) {
        ... -OpcUaUrl (Get-Or $modbus "opcUaUrl" $OpcUaUrl) ...
    }

Verified end-to-end with live docker-compose fixtures:
 - Modbus / AB CIP / S7 each run to completion, report 2/5 PASS (the
   driver-only stages) and FAIL the 3 server-bridge stages (expected —
   server-side factory wiring is blocked on #209).
 - The FINAL MATRIX header renders cleanly with SKIP rows for the
   drivers not present in the sidecar + FAIL rows for the present ones.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 10:55:15 -04:00
5834d62906 Merge pull request 'Task #253 follow-up — driver-side e2e debug: port fixes + HR[200] scratch register' (#214) from task-253c-e2e-debug-driver-side into v2 2026-04-21 10:34:22 -04:00
Joseph Doherty
fe981b0b7f Task #253 follow-up — driver-side e2e debug: port fixes + HR[200] scratch register
Ran the driver CLIs against the live docker-compose fixtures to debug
what actually works. Two real bugs surfaced:

1. `e2e-config.sample.json` pointed at the wrong simulator ports:
     - Modbus: 5502 → **5020** (pymodbus compose binding)
     - S7:      102 → **1102** (python-snap7, non-priv port)
     - AbCip:   no port → now explicit **:44818**
   `test-modbus.ps1` default `-ModbusHost` also shipped with 5502;
   fixed to 5020.

2. Modbus loopback was off-by-2 because pymodbus `standard.json` makes
   HR[100] an auto-increment register (value ticks on every poll).
   Switched `test-modbus.ps1` to **HR[200]** (scratch range in the
   profile) + updated sample config `bridgeNodeId` to match.

Also fixed the AbCip probe: `-t @raw_cpu_type` was rejected by the
driver's TagPath parser ("malformed TagPath"). Probe now uses the
user-supplied `-TagPath` for every family. Works against both
ab_server and real controllers.

Verified driver-side against live containers:
 - Modbus  5020:  probe ✓, HR[200] write+read round-trip ✓
 - AB CIP  44818: probe ✓, TestDINT write+read round-trip ✓
 - S7      1102:  probe ✓, DB1.DBW0 write+read round-trip ✓

## Known blocker (stages 3-5)

README now flags — and the 4 child issues under umbrella #209 track —
that `src/ZB.MOM.WW.OtOpcUa.Server/Program.cs:98-104` only registers
Galaxy + FOCAS driver factories. `DriverInstanceBootstrapper` silently
skips any `DriverType` without a registered factory, so stages 3-5
(anything crossing the OPC UA server) can't work today even with a
perfect Config DB seed. Issues #210-213 scope the factory + seed SQL
work per driver.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 10:31:55 -04:00
7b1c910806 Merge pull request 'Task #253 follow-up — bidirectional + subscribe-sees-change e2e stages' (#208) from task-253b-e2e-bidirectional into v2 2026-04-21 10:11:08 -04:00
Joseph Doherty
a9b585ac5b Task #253 follow-up — bidirectional + subscribe-sees-change e2e stages
The original three-stage design (probe / driver-loopback / forward-
bridge) only proved driver-write → server-read. It missed:

 - OPC UA write → server → driver → PLC (the reverse direction)
 - server-side data-change notifications actually firing (a stale
   subscription can still let a read-after-the-fact return the new
   value and look fine)

Extend _common.ps1 with two helpers:

 - Test-OpcUaWriteBridge: otopcua-cli write the NodeId -> wait 3s ->
   driver CLI read the PLC side, assert equality.
 - Test-SubscribeSeesChange: Start-Process otopcua-cli subscribe in the
   background with --duration N, settle 2s, driver-side write, wait for
   the subscription window to close, assert captured stdout contains
   the new value.

Wire both into test-modbus / test-abcip / test-ablegacy / test-s7 /
test-focas / test-twincat after the existing forward-bridge stage.
Update README to describe the five-stage design + note that the
published NodeId must be writable for stages 4 + 5.

Also prepend UTF-8 BOM to every script in scripts/e2e so Windows
PowerShell 5.1 parsers agree on em-dash byte sequences the way
PowerShell 7 already does. The scripts still #Requires -Version 7.0 —
the BOM is purely defensive for IDE / CI step parsers.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 10:08:52 -04:00
097f92fdb8 Merge pull request 'Task #253 — E2E CLI test scripts + FOCAS test-client CLI' (#207) from task-253-e2e-cli-test-scripts into v2 2026-04-21 09:58:34 -04:00
Joseph Doherty
8d92e00e38 Task #253 — E2E CLI test scripts + FOCAS test-client CLI
The driver-layer integration tests confirm the driver sees the PLC, and
the Client.CLI tests confirm the client sees the server. Nothing glued
them end-to-end until this PR.

- scripts/e2e/_common.ps1: shared helpers — CLI invocation (published-
  binary OR `dotnet run` fallback), Test-Probe / Test-DriverLoopback /
  Test-ServerBridge (all return @{Passed;Reason} hashtables).
- scripts/e2e/test-<modbus|abcip|ablegacy|s7|focas|twincat>.ps1: per-
  driver three-stage script (probe → driver-loopback → server-bridge).
  AB Legacy / FOCAS / TwinCAT are gated behind *_TRUST_WIRE env vars
  since they need real hardware (#222) or a licensed runtime (#221).
- scripts/e2e/test-phase7-virtualtags.ps1: writes a Modbus HR, reads
  the server-side VirtualTag (VT = input * 2) back via OPC UA, triggers
  + clears a scripted alarm. Exercises the Phase 7 CachedTagUpstreamSource
  + ScriptedAlarmEngine path.
- scripts/e2e/test-all.ps1: reads e2e-config.json sidecar, runs each
  present driver, prints a FINAL MATRIX (PASS/FAIL/SKIP). Missing
  sections SKIP rather than fail hard.
- scripts/e2e/e2e-config.sample.json: commented sample — each dev's
  NodeIds are local-seed-specific so e2e-config.json is .gitignore-d.
- scripts/e2e/README.md: full walkthrough — prereqs, three-stage design,
  env-var gates, expected matrix, why this is separate from `dotnet test`.

Tasks #249-#251 shipped Modbus/AbCip/AbLegacy/S7/TwinCAT CLIs but left
FOCAS out. Since test-focas.ps1 needs it, the 6th CLI ships here:

- src/ZB.MOM.WW.OtOpcUa.Driver.FOCAS.Cli: probe/read/write/subscribe
  commands, AssemblyName `otopcua-focas-cli`. WriteCommand.ParseValue
  handles the full FocasDataType enum (Bit/Byte/Int16/Int32/Float32/
  Float64/String — no UInt variants; the FOCAS protocol exposes signed
  PMC + Fanuc-Float only). Default DataType is Int16 to match the PMC
  register convention.

Full-solution build clean (0 errors). FOCAS CLI wired into
ZB.MOM.WW.OtOpcUa.slnx. No .Tests project for the FOCAS CLI yet —
symmetric with how ProbeCommand has no unit-testable pure logic in the
other 5 CLIs either; WriteCommand.ParseValue parity will land in a
follow-up to keep this PR scoped.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 09:51:13 -04:00
1507486b45 Merge pull request 'Task #252 — docs/ index + parent doc for the driver CLI suite' (#206) from task-252-driver-cli-index into v2 2026-04-21 08:57:24 -04:00
Joseph Doherty
adce4e7727 Task #252 — docs/ index + parent doc for the driver CLI suite
Per-CLI runbooks (Driver.{Modbus,AbCip,AbLegacy,S7,TwinCAT}.Cli.md) shipped
with #249-#251 but docs/README.md's Client tooling table never grew entries
for them and there was no parent doc pulling the suite together.

Adds:
  - docs/DriverClis.md — short parent. Index table, shared-commands callout
    (probe / read / write / subscribe), Driver.Cli.Common infrastructure
    note (what's shared, marginal cost of adding a sixth CLI), typical
    cross-CLI workflows (commissioning, bug reproduction, recipe-write
    validation, byte-order debugging), known gaps that cross-ref the
    per-CLI docs (AB Legacy ab_server upstream gap, S7 PUT/GET enable,
    TwinCAT AMS router, UDT-write refusal), tracking pointer to #249-251.
  - docs/README.md — Client tooling table grows 6 rows (DriverClis parent
    + 5 per-CLI). Also corrects the Client.CLI.md row: it's otopcua-cli,
    not lmxopcua-cli (renamed in #208).

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 08:55:17 -04:00
4446a3ce5b Merge pull request 'Task #251 — S7 + TwinCAT test-client CLIs (driver CLI suite complete)' (#205) from task-251-s7-twincat-cli into v2 2026-04-21 08:47:03 -04:00
Joseph Doherty
4dc685a365 Task #251 — S7 + TwinCAT test-client CLIs (driver CLI suite complete)
Final two of the five driver test clients. Pattern carried forward from
#249 (Modbus) + #250 (AB CIP, AB Legacy) — each CLI inherits Driver.Cli.Common
for DriverCommandBase + SnapshotFormatter and adds a protocol-specific
CommandBase + 4 commands (probe / read / write / subscribe).

New projects:
  - src/ZB.MOM.WW.OtOpcUa.Driver.S7.Cli/ — otopcua-s7-cli.
    S7CommandBase carries host/port/cpu/rack/slot/timeout. Handles all S7
    atomic types (Bool, Byte, Int16..UInt64, Float32/64, String, DateTime).
    DateTime parses via RoundtripKind so "2026-04-21T12:34:56Z" works.
  - src/ZB.MOM.WW.OtOpcUa.Driver.TwinCAT.Cli/ — otopcua-twincat-cli.
    TwinCATCommandBase carries ams-net-id + ams-port + --poll-only toggle
    (flips UseNativeNotifications=false). Covers the full IEC 61131-3
    atomic set: Bool, SInt/USInt, Int/UInt, DInt/UDInt, LInt/ULInt, Real,
    LReal, String, WString, Time/Date/DateTime/TimeOfDay. Structure writes
    refused as out-of-scope (same as AB CIP). IEC time/date variants marshal
    as UDINT on the wire per IEC spec. Subscribe banner announces "ADS
    notification" vs "polling" so the mechanism is obvious in bug reports.

Tests (49 new, 122 cumulative driver-CLI):
  - S7: 22 tests. Every S7DataType has a happy-path + bounds case. DateTime
    round-trips an ISO-8601 string. Tag-name synthesis round-trips every
    S7 address form (DB / M / I / Q, bit/word/dword, strings).
  - TwinCAT: 27 tests. Full IEC type matrix including WString UTF-8 pass-
    through + the four IEC time/date variants landing on UDINT. Structure
    rejection case. Tag-name synthesis for Program scope, GVL scope, nested
    UDT members, and array elements.

Docs:
  - docs/Driver.S7.Cli.md — address grammar cheat sheet + the PUT/GET-must-
    be-enabled gotcha every S7-1200/1500 operator hits.
  - docs/Driver.TwinCAT.Cli.md — AMS router prerequisite (XAR / standalone
    Router NuGet / remote AMS route) + per-command examples.

Wiring:
  - ZB.MOM.WW.OtOpcUa.slnx grew 4 entries (2 src + 2 tests).

Full-solution build clean. Both --help outputs verified end-to-end.

Driver CLI suite complete: 5 CLIs (otopcua-{modbus,abcip,ablegacy,s7,twincat}-cli)
sharing a common base + formatter. 122 CLI tests cumulative. Every driver family
shipped in v2 now has a shell-level ad-hoc validation tool.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 08:44:53 -04:00
ff50aac59f Merge pull request 'Task #250 — AB CIP + AB Legacy test-client CLIs' (#204) from task-250-abcip-ablegacy-cli into v2 2026-04-21 08:34:49 -04:00
Joseph Doherty
b2065f8730 Task #250 — AB CIP + AB Legacy test-client CLIs
Second + third of the four driver test clients. Both follow the same shape as
otopcua-modbus-cli (#249) and consume Driver.Cli.Common for DriverCommandBase +
SnapshotFormatter.

New projects:
  - src/ZB.MOM.WW.OtOpcUa.Driver.AbCip.Cli/ — otopcua-abcip-cli.
    AbCipCommandBase carries gateway (ab://host[:port]/cip-path) + family
    (ControlLogix/CompactLogix/Micro800/GuardLogix) + timeout.
    Commands: probe, read, write, subscribe.
    Value parser covers every AbCipDataType atomic type (Bool, SInt..LInt,
    USInt..ULInt, Real, LReal, String, Dt); Structure writes refused as
    out-of-scope for the CLI.
  - src/ZB.MOM.WW.OtOpcUa.Driver.AbLegacy.Cli/ — otopcua-ablegacy-cli.
    AbLegacyCommandBase carries gateway + plc-type (Slc500/MicroLogix/Plc5/
    LogixPccc) + timeout.
    Commands: probe (default address N7:0), read, write, subscribe.
    Value parser covers Bit, Int, Long, Float, AnalogInt, String, and the
    three sub-element types (TimerElement / CounterElement / ControlElement
    all land on int32 at the wire).

Tests (35 new, 73 cumulative across the driver CLI family):
  - AB CIP: 17 tests — ParseValue happy-paths for every Logix atomic type,
    failure cases (non-numeric / bool garbage), tag-name synthesis.
  - AB Legacy: 18 tests — ParseValue coverage (Bit / Int / AnalogInt / Long /
    Float / String / sub-elements), PCCC address round-trip in tag names
    including bit-within-word + sub-element syntax.

Docs:
  - docs/Driver.AbCip.Cli.md — family ↔ CIP-path cheat sheet + examples per
    command + typical workflows.
  - docs/Driver.AbLegacy.Cli.md — PCCC address primer (file letters → CLI
    --type) + known ab_server upstream gap cross-ref to #224 close-out.

Wiring:
  - ZB.MOM.WW.OtOpcUa.slnx grew 4 entries (2 src + 2 tests).

Full-solution build clean. `otopcua-abcip-cli --help` + `otopcua-ablegacy-cli
--help` verified end-to-end.

Next up (#251): S7 + TwinCAT CLIs, same pattern.

Co-Authored-By: Claude Opus 4.7 (1M context) <noreply@anthropic.com>
2026-04-21 08:32:43 -04:00
9020b5854c Merge pull request 'Task #249 — Driver test-client CLIs: shared lib + Modbus CLI first' (#203) from task-249-driver-cli-common-modbus into v2 2026-04-21 08:17:20 -04:00