The historian's Int1 analog-tag creation path is server-degenerate:
EnsureTags(Int1) stores an unusable stub (live-probed on the deployed
2023 R2 historian; root-caused + documented gateway-side in
HistorianGateway #11 / PR #16). HistorianTypeMapper mapped
DriverDataType.Boolean -> HistorianDataType.Int1, so Boolean historized
tags failed auto-provisioning.
Map Boolean -> Int2 instead (store 0/1). Int2 is a proven-creatable
analog type, and the value-write path already sends every value as a
double on WriteLiveValues regardless of tag type, so Boolean 0.0/1.0
round-trips cleanly. Both Float and Int2 are supported, so a
pre-existing Float Boolean tag retypes cleanly on its next deploy.
- HistorianTypeMapper: Boolean => Int2 (+ remarks)
- Unit pins: HistorianTypeMapperTests, GatewayTagProvisionerTests
(Boolean_definition_carries_explicit_Int2_presence)
- Live gate: EnsureTags_boolean_sandbox_provisions_as_Int2 (was _Int1);
retype probe reframed Float->Int2 (drops the dead Int1 leg)
- Docs: docs/Historian.md 'Boolean historization maps to Int2', CLAUDE.md,
archreview STATUS.md (R2-06 live gate -> 6/6)
Resolves#441.
GatewayTagProvisioner built HistorianTagDefinition without a StorageRateMs, so
the proto uint32 defaulted to 0. The gateway's EnsureTags maps StorageRateMs
straight to the AVEVA SDK's storageRateMs, which requires a positive value —
0 makes the SDK throw ArgumentOutOfRangeException ('Storage rate must be > 0 ms'),
so EVERY historized-tag auto-provision (the deploy-time IHistorianProvisioning
hook) silently failed at the gateway with failed=N.
Stamp DefaultStorageRateMs=1000 (matches the gateway's own live provisioner
convention; quantized 1000/5000/10000). Add a regression unit test asserting the
definition carries a positive rate, and set StorageRateMs on the live-suite's
inline definitions so the retype probe reaches a real EnsureTags.
Found via the R2-06 live gate against a real 0.2.0 gateway + AVEVA historian:
with this fixed, Float/Int2/UInt2/Int4/UInt4/Double all provision and the live
suite goes 3/6 -> 5/6. (Int1/Boolean remains blocked by the gateway histsdk's
ProtocolEvidenceMissingException for Int1 — a gateway-side type-support gap, not
this bug.)
Gateway driver unit 103/103.
Four continuous-historization types (IHistorizationOutbox, HistorizationOutboxEntry,
IHistorianValueWriter/HistorizationValue, HistorizationCommitMode) drifted into a
ZB.MOM.WW.OtOpcUa.Core.Abstractions.Historian sub-namespace while the other six files
in the same folder correctly use the root namespace. This violated decision #59's
flat-public-surface rule and left InterfaceIndependenceTests.AllPublicTypes_LiveInRootNamespace
red on master (pre-existing, predates round-2 remediation).
Move all four to the root namespace and drop/retarget the now-redundant
'using ...Core.Abstractions.Historian;' in the ~11 consumers. No behavioral change.
Verified: Core.Abstractions.Tests 129/129 (was 128/129), Runtime.Tests Historian+DI 72/72,
Gateway driver unit 102/102, full solution build 0 errors.
Models gain an optional bool? Writable (absent stays omitted; explicit false round-trips,
unknown keys preserved); the six editors gain a Writable checkbox (FOCAS disabled+read-only
hint). 9 model round-trip tests green. docker-dev /run verify of one editor deferred-live.
Findings 01/S-1 (AddressSpaceApplyOutcome failure field + apply.failed logging,
no optimistic success), 06/S-1 (Galaxy write fails closed -> BadCommunicationError
+ #5 revert, no knowingly-lost raw Write), 03/S4 (PrimaryGatePolicy default-deny
unknown-role-multi-driver on all gates + scripted-alarm emit gate). T13/T15 (2-node
live gates) deferred -- T15 is the behavior-affecting S4 live gate, must run in heavy
pass. Clean merge, build clean.