Staleness is not a liveness proof: DriverInstanceActor publishes on a 30 s
tick and dedups on a health fingerprint, so a running Faulted, idle or
tagless driver deleted in /raw (undeployed) went stale and was evicted.
DeployedDriverSet reads, per node, the latest and latest-Applied
NodeDeploymentState deployments plus the latest Sealed one, parses each
artifact's DriverInstances once (cached by deployment id, pruned to the live
set, only the blob column of an uncached row is read), and /hosts unions it
with the authored set. The staleness clause stays as a second guard. An
unreadable artifact or a failed read means 'unknown' and skips eviction.
The Hosts.razor comment claiming '~12 health publishes' is corrected.
N-new-2: the CSV download's Content-Disposition carries an RFC 5987
filename* via ContentDispositionHeaderValue.SetHttpFileName.
Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
I1: /hosts eviction keyed off the AUTHORED DriverInstances, so a driver
deleted in /raw but not yet deployed - still running, still publishing -
vanished every tick. The stores' sweep is now EvictUnconfiguredStale(set,
olderThanUtc): an entry goes only when unconfigured AND its PublishedUtc is
older than 60 s. Tests cover unconfigured+fresh kept (positive control),
unconfigured+stale evicted, configured+stale kept, and the deploy hand-off.
M1: Test Connect falls back to the driver's documented ProbeTimeoutSeconds
default (Galaxy 30, OpcUaClient 15, ...) when the key is absent.
M2: the budget never undercuts the config's root timeoutMs (+1 s).
M5: RawBrowseModal compares the open generation captured before the await,
so a close-then-reopen mid-open closes the stale session.
M6: /alarms-historian keeps a 30 s re-poll on 'not registered' (a driver
node may still be starting) instead of stopping for good.
M7: /scripts source fetch failure shows in the dialog, not the error boundary.
M8: the export modal maps only its preview rows; the endpoint writes via
Results.Text (no second byte[] copy).
M9: /hosts config queries are ordered, so SequenceEqual change detection holds.
N1 tooltip, N2 CRLF-safe regex, N3 throttled Warning for subscriber faults,
N5 equipment-import help text now describes RFC 4180 quoting.
H3: MonacoEditor documents that themes are page-global.
Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
RequestRebirthAsync now returns only once the requested births have arrived
and gone quiet, but the modal still told the operator to re-expand the tree in
a few seconds. ConfirmRebirthAsync re-keys the tree against the same session
(as the Refresh button does) when the session and modal are still current,
drops the now-stale armed scope, and keeps the outcome line.
Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Since R06:M-5 the Sparkplug browser states no address for a metric the
ingestor will not read and labels its descriptor 'not bindable', but the commit
refusal still said the attribute lookup returned nothing. RawBrowseModal keeps
the attribute's descriptor on the selection, and DescribeUncommittableLeaf
reports a 'cannot be bound in this version' message echoing it. A lookup that
really returned nothing keeps the old text. A test pins the marker to the
browser's own string.
Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
/fleet/diagnostics was reachable only by URL: each driver-role row on /fleet now
links to it (FleetDiagnosticsLinks.For escapes the host:port node id). The
diagnostics table showed the string instance id because the wire carries no
display name; the page now joins the authored DriverInstances.Name from the
ConfigDb (enrichment only - a failed lookup falls back to the id) and keeps the
id beneath the name.
Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The dev-only demo page shipped routable in the production assembly. Its route
moves from @page to a code-behind [Route] under #if DEBUG, so a Release build
keeps the component type (nothing referencing it breaks) but has no /dev/*
route. The page-authorization guard classifies it under #if DEBUG, and
DevRouteGatingTests asserts each configuration's half (Debug: exactly the demo
route; Release: none) with a positive control. Both configurations pass.
Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
ImportEquipmentModal split each line on commas, so a quoted Manufacturer with
a comma silently shifted every later column. EquipmentCsvParser reads through
the shared Commons CsvParser (the raw-tag importer's authority): quoted
fields, doubled quotes, CRLF and blank lines parse; malformed quoting is an
error, not a guess. Header/shape messages are unchanged.
Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
v3 retired the equipment-Tag binding; IUnsTreeService.LoadTagsForEquipmentAsync
always returned empty, had no production caller, and EquipmentTagRow plus the
always-zero tagCounts / EquipmentRow.TagCount plumbing existed only to feed it.
All removed; the equipment badge count (virtual tags) is unchanged.
Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The equipment page's Remove reference / Delete virtual tag / Delete alarm row
buttons and the ScriptEdit Delete ran on the first click. They now go through
RawConfirmDialog, the same confirm /raw uses. The ScriptEdit change is limited
to the delete button and its dialog.
Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
I-1 - a non-C# paste produced thousands of Roslyn markers. The Problems-list report sent
them all as one JS->.NET message, which could exceed the 1 MB hub limit and kill the
circuit. The JS now sends at most MaxReportedMarkers (200) markers, errors first, each
message cut to 300 chars, plus the total. ScriptProblemReport.FromEditor clamps again
on arrival, and the Problems list shows "showing N of Total" / "+N more". The diagnostics
endpoint also bounds its response: Distinct, errors first, MaxDiagnosticMarkers (1000),
messages cut to 1000 chars. An error is always kept, so editor-accepts == publish-accepts.
M-1 - drop the per-instance compilation lineage; analyses derive from BaseCompilation.
M-2 - the VirtualTag modal clears its problems (and editor ref) on close and on a script
reload.
M-5 - an over-limit text is announced at blur (OnSyncRefused), not only at Save.
Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Every picker and RawBrowseModal stored the OpenAsync token after the await; if
the host was disposed (or the modal closed) meanwhile, its teardown had already
run with no token, so the plant-side session lived until the reaper's idle TTL.
BrowseOpenGuard.CloseIfOrphaned closes it at once; each host sets _disposed
first thing in DisposeAsync (RawBrowseModal also treats !Visible as gone).
Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
A bare catch {} turned every failure - including an admin-only node with no
historian actor - into 'Loading...' forever, and a tick queued after a sync
timer dispose still issued an Ask. HistorianSinkStatusReader classifies a poll
as Available / NotOnThisRole (permanent: shown once, polling stops) /
Unavailable (shown with the last good status and its read time). The page
follows Fleet.razor: IAsyncDisposable, _disposed, overlap guard, page CTS.
Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
DriverTestConnectButton always sent a fixed 10 s, and the Galaxy/OpcUaClient
probes run under min(caller, configured), so ProbeTimeoutSeconds - documented
on every driver as the Test Connect timeout - could shorten a probe but never
lengthen it (Galaxy's 30 s default was silently 10 s). TestConnectBudget reads
the root ProbeTimeoutSeconds from the merged config at click time, clamped to
the actor's [1, 60] s, falling back to TimeoutSeconds. DeviceModal (the only
host) needs no change. The Galaxy/OpcUaClient form hints are reworded.
The 30 s result-clear timer moves from System.Timers.Timer + an async void
Elapsed lambda to System.Threading.Timer, drained in DisposeAsync, with a
generation so a superseded fire cannot clear a newer result.
Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
DriverConfigModal, DeviceModal and RawTagModal built a new parameter dictionary
and new EventCallbacks every render. ParameterDictionaryCache reuses the
dictionary while the values it carries are unchanged and rebuilds it with the
current value when one changes (a build-once cache would strand edits); the
callbacks are created once. Blazor still re-sets an EventCallback-bearing
child's parameters per parent render, so the forms' _lastParsed guards stay.
Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The import review grid rendered every parsed row and re-scanned all rows three
times per render for its counts; RawCsvReviewView recomputes rows + counts once
per change and the grid renders through Virtualize. The export modal embedded the
whole CSV twice (textarea + base64 data: URI); it now shows a 50-line preview
and links to GET /api/raw/tags.csv (ConfigEditor, like /raw), which runs the same
RawTagCsvExport builder and sends it as an attachment.
Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
R04:P1 - the editor no longer ships its full text JS->.NET on every keystroke. It reports
at blur, and ScriptEdit / the VirtualTag modal read the authoritative value with
MonacoEditor.GetValueAsync at Save (validation runs after the pull). The Blazor hub's
MaximumReceiveMessageSize is raised from 32 KB to 1 MB. The JS refuses a value that
would not fit instead of sending an oversize frame, and Save surfaces that refusal
rather than persisting stale source.
R04:P9 - diagnostics carry a generation counter and an AbortController. Every edit aborts
the in-flight request, and only the response for the current text is applied.
R04:S2 - the always-empty inlay-hints provider, endpoint, service method and contracts
are removed.
R04:S3 - MarkersChanged is typed (DiagnosticMarker) and feeds a new ScriptProblemsList.
Clicking a problem calls RevealLineAsync. Markers cross to .NET only when a list
subscribes.
Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The deploy API's 202 pointed at a route that did not exist. The GET reads the
deployment (projected, no artifact blob) and its per-node apply states, and
carries the POST's own gate: API key in X-Api-Key, AllowAnonymous against the
cookie fallback, 503 while Security:DeployApiKey is unset.
Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The recursive RenderNode rendered every row of an expanded device, and built a
fresh context-menu list + closures per node per render. RawTreeRows flattens the
expanded tree (explicit stack) into rows rendered by one Virtualize; each level
shows 500 children, then a 'Show more' row. RawNodeMenuCache keys menus weakly
on the node instance and rebuilds on a picker-mode or Enabled change.
Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
R04:P2 - every analysis derives from one process-wide bound base compilation via
ReplaceSyntaxTree (the scoped service keeps its current compilation); every entry point
takes the request token, the endpoints bind RequestAborted and answer 499 on abort, and
the Monaco providers abort their fetch when Monaco cancels the request.
R04:P3 - the catalog snapshot carries a sorted, de-duplicated string[] (binary-search
prefix completion) and an Ordinal path->info dictionary, built once per snapshot.
R04:S1 - Diagnose emits an OTSCRIPT_SETVTAG_INERT warning for each ctx.SetVirtualTag
call. It is a warning, so editor-accepts == publish-accepts still holds.
Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The list loaded every script entity including SourceCode to render names and
hashes. ScriptListQueries projects {ScriptId, Name, Language, SourceHash} for
the list and fetches one script's source when its Source dialog opens, with a
generation guard against a superseded open.
Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Each received event used to Insert(0) into a List and render the full page.
LiveTailBuffer queues events from the bridge thread into a bounded newest-first
ring; CoalescingRenderScheduler (TimeProvider-driven, drained on dispose)
flushes and renders at most once per 200 ms window. ScriptLog's filtered rows
are recomputed on flush/filter change instead of three times per render.
Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
OnSnapshotChanged used to re-project every cluster group and re-render the
whole page for each driver publish, per open tab. It now only marks a
CoalescingDirtyFlag; the 5 s tick rebuilds when the flag is set or the config
load changed (or evicted) anything.
Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The driver-status and resilience stores had no removal path, so a deleted
driver stayed on /hosts as a frozen row until restart. Both stores gain
RetainOnly, which /hosts calls after each successful config load (never on a
failed one).
The stores and InProcessBroadcaster now raise their events one subscriber at a
time, so a throwing handler cannot starve later subscribers or escape onto the
bridge actor. The alert/script-log bridges publish inside their try, and the
resilience bridge catches a store failure instead of restarting.
Refs #745
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
N3: a keyless blob carrying the addressResolved marker was served from its
string by the driver but saved as HR[0] by the editor model / CSV path. The
precedence rule now lives in ONE pure resolver in Driver.Modbus.Contracts
(ModbusTagAddressResolution.Classify/Resolve): keys when region+address are
both present, else a string-only addressString resolved with the driver's
family (refused when it cannot parse), else refused. The marker never decides.
Consumers that now ask it instead of restating it: the driver's tag reader
(ModbusTagDefinitionFactory.FromTagConfig), the deploy gate (Inspect /
DescribeRejection), the editor model (AddressShape / IsStringOnly /
HasKeyAddress / ResolveWith, ToJson stamping, Validate), the CSV export cells
and the editor hint. The model writes keys only when it loaded them or a field
was authored - never defaults it did not resolve (also closes two divergences
the new matrix found: malformed-string+marker and non-string addressString were
saved as HR[0]).
One table-driven test (ModbusAddressAuthorityAgreementTests) runs 15 persisted
shapes through driver, deploy gate, model load/save/Validate and the real CSV
export->import under all four families; breaking the CSV export or reverting
the model to the marker rule fails it.
Minors: m1 CSV address cells keep the string+marker while it still describes
them (lossless unchanged round trip), drop it when contradicted, and the review
grid reports the drop; m2 the pre-lane test uses the real export residual; m3
unmarked string-only + typed-cell case added; m4 stale docs/summary and the
unused factory parameter removed.
Refs #741
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
N2: pre-#741 rows carry region/address beside an addressString with no marker
(the old driver never read the string, the old model preserved it as an
unknown key). The r1 rule resolved those from the string - a silent remap or
BadNodeIdUnknown on upgrade. The driver now loads from region+address whenever
both are present (classic, editor-pinned, pre-lane); only a blob with NO keys
is string-only and resolved through the parser. This is safe because the model
no longer stamps keys onto a string-only tag. The model distinguishes
string-only / legacy-string-beside-keys / pinned, and the editor hint says so.
Test matrix over every persisted shape (keys only, pre-lane keys+string,
pre-lane stamped HR/0+string, string only, marker+keys, marker no keys) under
every family; the pre-lane row also through a model save and a CSV
export->import.
n5: a typed CSV address cell is an authored address - it drops addressString
and the marker (new CsvTypedColumn.ClearsKeys) instead of being discarded.
n6: Validate skips the region/dataType/byteOrder enum checks on a string-only
tag (the driver ignores them). n7: docs/v2/modbus-addressing.md restates the
key-presence rule.
Refs #741
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
N1: the m2 precedence trusted region/address whenever the keys were present,
but the AdminUI model stamps defaulted HoldingRegisters/0 on every save, so a
string-only tag (CSV import, or any editor toggle) silently became HR[0] -
reads AND writes. The resolved keys are now authoritative only when the editor
marked them ("addressResolved": true, written by Resolve); an unmarked
addressString is always resolved through the parser with the driver's family.
The model no longer stamps address fields for a string-only tag, CSV export
leaves its address cells blank, and the editor hint distinguishes string-only
from pinned tags. Tests: CSV import and editor save of a string-only tag, a
stamped-default blob, and the pinned positive control across families.
n1: docs/v2/modbus-addressing.md updated (FC23 opt-in, maxReadGap semantics,
coalescing scope, addressString/family rules, coil coercion, refusals).
n2: form round-trip tests for UseFC23ForMultiRegisterWrites /
DisableReadCoalescing. n4: the editor keeps unresolved address text when the
parent echoes back its own emit. n3: noted, no change.
Refs #741
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Coordinator rulings and Important findings from review r0:
1. FC23 is opt-in (new UseFC23ForMultiRegisterWrites, default false); a config
without it - including the persisted "disableFC23": false every form-saved
config carries - keeps the FC16 wire. DisableFC23 stays the hard kill-switch.
2. An explicit maxReadGap 0 means coalescing off again (its pre-lane meaning);
the gap-8 default applies only to an absent key.
3. Coils/DiscreteInputs tags persisted with a register dataType (the old
editor saved Int16) are coerced to Bool, never refused, with no deploy
warning (a warning can be promoted to a blocking error). The editor loads
them as Bool. Register region + Bool is still refused.
4. One comms-fault slot for reads and writes: a good read clears a write's
transport fault and vice versa.
Minors: Dispose writes its own Unknown health (m1); persisted region/address
are authoritative over addressString so a Family change cannot remap a live
tag (m2); a malformed-but-delivered reply no longer fails the unit fast (m3);
a fresh socket published after a concurrent dispose is torn down (m4); the
editor resets address text per tag (m5); master merged (m6); the FC23 latch
log says re-init restores it (m7). Back-compat tests use the old persisted
JSON shapes and fail without the fixes.
Refs #741
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
U1: a tag's addressString (Modicon / mnemonic / DL205 V-memory / MELSEC
D-X-Y grammar) now resolves through ModbusAddressParser with the DRIVER's
Family and MelsecSubFamily at every initialize and is authoritative; the
family-unaware gates (deploy Inspect, AdminUI parse consult) accept what
some family resolves. The tag editor gets an address-text field that
resolves with the owning driver's family and persists both the string and
the resolved region/offset/type fields; a hand edit drops the string.
DisableFC23 now gates FC23: by default a 2..121-register holding write is
one FC23 write + read-back (a unit answering exception 01, or failing FC23 at
the transport, moves to FC16 for the rest of the generation); RTU framing
deframes the FC23 reply. Live-checked: the pymodbus fixture implements FC23.
Also: the AdminUI driver form serialises ModbusDriverOptions (TimeSpan
strings), which the factory DTO never read - every timing field on the form
was dead. The DTO now accepts both shapes (*Ms keys win).
Refs #741
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Review r0 M9. The AdminUI form wrote coalesceReads:true on every save, pinning
today's default into every edited driver. AbLegacyDriverOptions.CoalesceReads
is now bool? (null = default ON, never serialised, same encoding as
Transport); the form omits the key when the switch is on and writes only an
explicit false. Persisted coalesceReads:true keeps loading as on.
Refs #738
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Review r0 I3. The array encoder used the AUTHORED dataType's width while both
runtimes size their buffer from the FILE: an Int array on F8 wrote four shorts
into a 16-byte float buffer and sent it all (garbage neighbours, answered
Good); Long/Float on N overran it.
- The write path resolves the element width from the data file the address
names (N/B/A/I/O/S 16-bit word, L 32-bit, F float) and encodes at THAT width.
- An authored type that does not match its file is refused BadTypeMismatch
before any runtime exists (warned once, no health write).
- The same rule (AbLegacyTagDefinitionFactory.ArrayFileMismatch) backs an
Inspect deploy warning and the AdminUI model's Validate error; FromTagConfig
still accepts the tag so persisted configs keep loading.
- M6: the skipped F1 parity test gains the shapes the write path refuses
(/bit, .sub, indirect, type/file mismatch, PLC-5 native).
Tests: one case per file type, a mismatch per pairing with nothing created,
and a positive control.
Refs #738
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
P6: Coils/DiscreteInputs carry only Bool and register regions never Bool;
the factory (and so the deploy-gate Inspect and the AdminUI parse consult)
refuses a mismatch, and an absent dataType defaults per region (Bool for a
bit region). A HoldingRegisters+Bool tag used to throw out of the coalescing
planner and stall every tag of the subscription; the planner also skips any
incompatible pair defensively. The tag editor keeps the type compatible when
the region changes; the CLI refuses the pair up front. The array-write parity
test records the Coils divergence from DriverArrayWriteSupport (owned outside
this lane) as follow-up F1.
Refs #741
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
PageAuthorizationGuardTests.EveryRoutablePage_isClassifiedAndMatchesExpectedPolicy
was red on master: the FleetDiagnostics page (lane A, 953bd275) was
routable but unclassified. It declares AuthenticatedRead, the same
policy as /fleet, and is classified as such. Count comment 16 -> 17.
Refs #731#734
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
The init-time tag guards THREW: one mis-authored tag (DB1.DBZ0, DB1.DBW0 typed
Float64, T5 typed Int32, a writable Bool array) faulted the whole driver and the
actor retried the same init every 10 s forever, darkening every tag on the PLC.
Neither the editor nor the deploy gate checked any of it.
- S7AddressParser moves to S7.Contracts (same namespace) and a new
S7TagShapeRules there is the single authority on servable shapes.
- S7TagDefinitionFactory.FromTagConfig applies it, so the AdminUI editor, the
deploy gate (Inspect, with the specific reason) and the driver init refuse
the same tags. Init now skips a refused tag (ISkippedTagReporter) instead of
throwing; the throwing RejectUnsupportedTagConfigs is gone.
- New rules on top of the old guards: a narrow type at the wrong access width
(every read failed) and a Bool array not starting at bit 0 (U4: DB1.DBX0.3
silently read bit 0 of bytes 0..n).
- AdminUI test fixtures that used addresses the driver could never serve
(DB1.DBS0, a browse "SomeAddress", Int32/Float32 on DBW) now use real ones.
Refs #742
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Review 07 P7 (rest): adjacent words on one data file were never coalesced
(one round trip per tag) although the array path proves the transport can read
a span. Within a device pass, scalar tags on one N/B/F/L file within 8
elements of each other (block <= 200 data bytes, under the 236-byte typed-read
limit) now ride one multi-element read and are decoded from their offsets with
exactly the CLR types the single-tag path returns (int / float / bool).
Only shapes the single path decodes identically are coalesced: indirect,
sub-element, array, file-number-less (S:/I:/O:) and width-mismatched tags keep
the single path. A block the device refuses (an authored element past the end
of the file, a native PLC-5 non-N file) falls back to per-tag reads for its
members and its shape is remembered; a comms fault fails the members together.
New driver-config key coalesceReads (default true) with an AdminUI switch
(Razor change: AbLegacyDriverForm, for the Wave 4 live check). Adds an
env-gated ab_server parity case (coalesced == per-tag values).
Refs #738
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
ScriptContext.CancellationToken is backed by an AsyncLocal that
ScriptEvaluator.RunAsync scopes around the compiled delegate, so it is
exactly the token ScriptRunGuard cancels on timeout. A polling script
can now end its own abandoned run and free the slot. AsyncLocal rather
than a field because the scripted-alarm engine reuses one context per
alarm: an orphan keeps seeing its own cancelled token. The scoping
entry point is internal (IVT to Core.Scripting) so a script cannot
replace its own token.
Editor parity: ScriptAnalysisService dot-completion now walks the
receiver's base chain (instance members only, stopping before
System.Object). Before this, a member declared only on ScriptContext
compiled and published but never completed. DiagnoseTests pins the
member as allow-listed; CompletionTests pins the completion.
Refs #731#734
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Review 07 H16: an array of String/Timer/Counter/Control passed the mapper, so
every poll created a handle (one init read), the decode threw
NotSupportedException, the generic catch evicted the handle and latched
Degraded. FromTagConfig now rejects that combination (the skip carries the
reason, Inspect/deploy gate and the AdminUI model state it), and a runtime
NotSupportedException on read or write is BadNotSupported: handle kept, no
health write, one Warning per tag and operation. Write refusals (native PLC-5
and status-bit writes, libplctag translated addresses) now warn once per tag too.
Refs #738
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
FocasDataType.String was authorable on any address, but no area read returns text: PMC
fell through to a byte read, PARAM to Int32, MACRO to a double, and the String node
received a boxed number at Good.
One rule, FocasTagDefinitionFactory.DescribeDataTypeMismatch, now backs every path:
- FromTagConfig rejects the pair, so the driver skips + reports it (BadNodeIdUnknown,
never a Good number) and Inspect names the reason at deploy;
- FocasTagConfigModel.Validate refuses it on the typed fields;
- the AdminUI editor only offers String where it is readable and shows the rule's text
inline (kept visible for a loaded blob that already carries it);
- the CLI read/subscribe/probe/write commands refuse it at the boundary.
String stays valid on FIXED: paths (Identity/Program name/mode text) and is ignored on
ALARM: tags; an unparseable address keeps its own diagnosis.
Razor change (FocasTagConfigEditor.razor) needs the Wave 4 live check.
Refs #740
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
R05:10 — the namespace deny-list covered System.Threading.Tasks but not
System.Threading, so SemaphoreSlim / Monitor / SpinWait / Mutex /
EventWaitHandle could park a script's pool thread past its budget (or touch a
system-global kernel object); System.Type.GetType(string) / GetMethod* /
InvokeMember and System.Runtime.CompilerServices.RuntimeHelpers resolved and
reach a forbidden type without naming it syntactically.
ForbiddenTypeAnalyzer now denies the whole System.Threading namespace with a
type-granular allow-list (CancellationToken, Interlocked, Volatile — the
sync-free primitives), adds a member deny-list for System.Type's reflection
entry points (GetType/GetMethod(s)/InvokeMember/GetProperty(ies)/GetField(s)/
GetMember(s)/GetConstructor(s)/GetEvent(s)/GetDefaultMembers; instance
object.GetType() stays allowed) and puts RuntimeHelpers on the type deny-list.
Thread/ThreadPool/Timer leave the type list — the prefix rule reaches them.
R05:11 — the allocation budget landed with E1's ScriptRunGuard
(Scripting:MaxAllocBytesPerRun, default 64 MB): sampled around each run,
breach quarantines. It is observation after the fact; a pre-emptive OOM guard
still needs an out-of-process runner (follow-up issue in the lane report).
The Monaco editor shares the analyzer, so DiagnoseTests pins every new form
as an OTSCRIPT_FORBIDDEN marker and every allow-listed form as clean.
Refs #734
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
CallTimeoutSeconds was bound, defaulted and documented but consumed
nowhere. TelemetryDialSupervisor now arms a per-generation deadline on
every dial: a dial that has delivered no event by the deadline is
cancelled and treated as a transport failure (reconnect with a failure
streak). A live node replays its snapshots on subscribe, so this bites
only a dial that never connects (a black-holed host, where the socket
connect has no timeout). An established stream is deliberately not
bounded — the wire has no heartbeat, keepalive pings own its liveness.
Review ref: 02/U2.
Refs #731
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
- Endpoint rewrite: the driver now connects to the configured host AND port (scheme
match, advertised path kept) instead of the server-advertised URL — fixes NAT/port-map
upstreams and lets an in-test proxy carry the session (SDK SelectEndpoint rule).
- TcpStallProxy + OpcUaClientDriverStallWireTests: the in-place blip (#670) is now
wire-tested on loopback — one Bad, frozen read stamp, same session, identical value
republished Good, a post-recovery change arrives, no source-time regression after
the SDK's late backlog flush.
- Defect found by that test, fixed: a change published right after a stall rode a
Publish response the SDK timed out and never republished, leaving the node Good on
the pre-change value indefinitely. New trailing reconcile read (Timeout +
KeepAliveInterval after recovery) publishes any Good value newer than the last
accepted one, through the replay guard's mark.
- IDriverConnectionLossSource (Core.Abstractions): opt-in definitive-loss signal.
DriverInstanceActor attaches in PreStart / detaches in PostStop and turns a raise
into a disconnect only while Connected. OpcUaClient raises once per session on
keep-alive BadSessionIdInvalid/BadSessionClosed/BadSessionNotActivated/
BadServerHalted (measured: the SDK never re-opens a halted channel) or a dropped
subscription; ambiguous codes stay with the #527 watchdog.
- Replay guard: one Information summary per recovery when the window closes
("dropped N late notifications across M refs"), with a timer so quiet
subscriptions log it too.
- ReconnectPeriod deleted (options, AdminUI form, docs, tests); stored configs that
carry reconnectPeriod still parse in the factory, probe and browser.
- Docs: OpcUaClient.md, DriverLifecycle.md, driver-specs.md, CLAUDE.md.