Joseph Doherty 7482a88888 fix(opcua): deferred condition events never outlive their condition; per-condition bounded deferral; canonical lockout identity (#838, #844 review)
#838 review of 91e28e87:
1. Ghost events. The deferred report ran the SDK walk off Lock with no
   liveness check, so an event waiting behind a full channel when a deploy
   removed its condition still reached i=2253 subscribers after the NodeDeleted
   (a ghost Retain alarm for ScadaBridge) and folder items. Delivery now walks
   the SDK path itself (OnReportEvent, OnReportEventAsync, inverse notifiers,
   then the Parent as BaseInstanceState does) re-checking before EVERY hop that
   the condition is the live instance; OnConditionReportEvent checks the same,
   which also stops a non-live scripted condition being admitted through its
   old equipment folder (#808). A guard test pins that only NodeState and
   BaseInstanceState define the walk. New wire test removes the condition in
   the same Lock hold as a flood; the flag-off variant fails without the checks.
2. Back-pressure. Deferral is per condition (one condition's events stay
   ordered; others are not held up). Overflow policy: coalesce, newest wins --
   past 1024 waiting per condition or 65,536 total, the oldest not-yet-started
   event is discarded (a condition event carries full state). Warning on
   entering deferral (<=1/min), Information on draining, meters
   otopcua.opcua.condition_events.deferred / .discarded{reason}.
3. Verified by decompiling SDK 2.0.1: the notifier list is snapshotted under the
   node's own lock, MonitoredNode2.Dispose completes its writer (pending writes
   fail with ChannelClosedException, swallowed), and the consumer catches
   per-event exceptions -- no fix needed; documented.
4. ConditionRefresh does not flush deferrals; documented as a residual.

#844 review: DescribeCredential canonicalises the key id (trim, lowercase;
non-hex ids fold into one identity) and the username, since ConfigDbApiKeyStore
matches with SQL Server's case-insensitive, trailing-space-blind `=`.
2026-11-11 04:35:30 -05:00
Joseph Doherty 91e28e87be fix(opcua): condition events never block under the node-manager lock; folder-event Part 3 note (#838)
#838(a): each notifier's SDK MonitoredNode2 drains a bounded channel (4096,
FullMode=Wait) and the synchronous NodeState.ReportEvent blocks when it is
full. Condition events are reported under Lock, and the delivery task takes
Lock on a verdict-cache miss (the SDK's own GetNodeMetadata, flag off too, and
#826's IsNotifierEventVisibleTo). A burst of >4096 events under one Lock hold
therefore deadlocked the node manager -- FolderEventFloodWireTests stalled at
exactly 4097 events with enforcement on AND off (so it predates #826).

ReportConditionEvent now goes through ReportEventWithoutBlocking:
ReportEventAsync completes inline while channels have room (unchanged normal
path); on overflow the report continues asynchronously holding no thread or
lock, and later reports queue behind it so events keep report order. The
deferred work holds only frozen snapshots and drains once Lock is released;
client delivery stays bounded by each item's queue.

#838(b): documented in docs/security.md that Part 3 ReceiveEvents applies to
the event's EventType and SourceNode (the SDK check, kept first), not to the
notifier; our decision is layered on top and non-condition events on a folder
item fail closed under enforcement. The reflection item stays open.
2026-11-11 04:06:28 -05:00
Joseph Doherty ffba75bb93 fix(opcua): credential lockout counts per credential identity, ignores transient denials (#844, #845)
#844: a success cleared the whole per-client count, so a client holding a valid
key could make four guesses at another key id, sign in with its own, and repeat
forever. Failures are now charged to the (client, credential identity) pair --
IOpcUaUserAuthenticator.DescribeCredential, key:<keyId> for API keys -- and to
the client as a whole. A success clears only its own identity's count; the
per-identity threshold locks that identity; a new per-client cap
(OpcUa:CredentialLockout:MaxFailedAttemptsPerClient, default 2 x
MaxFailedAttempts) that a success never resets bounds spraying across key ids
and locks every credential. Slots are bounded on both counts; a waiter whose
identity has room is not held behind one whose identity has none.

#845: (1) store timeouts, miss-budget refusals, store/authenticator exceptions,
an unset pepper and cancellation are reported Transient
(OpcUaUserAuthResult.Unavailable) and released uncounted, so a ConfigDb stall
can no longer lock every keyed client out; the client still sees the same
opaque denial. (2) a full 4096-entry table defers its next prune until the
earliest entry could age out instead of rescanning under the lock per failure.
(3) ApplicationUri deliberately NOT added to the key: on a None channel it is a
free string, so it would let an attacker reset the count per guess --
documented. (4) wire tests: distinct client certificates on a Sign endpoint are
locked out separately; the ApplicationConfigPath branch keeps the SDK lockout
off (falsified by removing the loaded-branch disable).
2026-11-11 03:47:10 -05:00
Joseph Doherty 2314a53842 fix(opcua): parallel UserName activations wait for a slot instead of being refused (#833)
A legitimate consumer opening several keyed sessions at once from one key
(e.g. a ScadaBridge site node behind one NAT IP on a None endpoint) must
never see BadUserAccessDenied for parallelism. BeginAsync now hands out at
most MaxFailedAttempts - recordedFailures verification slots per key;
further activations queue FIFO and are woken as slots free. A waiter is
refused only when the key locks out (never reaching the authenticator) or,
uncounted, after OpcUa:CredentialLockout:SlotWaitSeconds (default 10,
BadTimeout). Cancelled waiters are dequeued; pruning accounts for waiters.
The security property is unchanged: no more than MaxFailedAttempts
unverified guesses in progress-or-failed per window.
2026-11-11 02:43:38 -05:00
Joseph Doherty 61b9adeb9c Merge branch 'master' into fix/832-docker-dev-batch 2026-11-11 02:32:42 -05:00
Joseph Doherty 5bfe8386e6 Merge fix/826-folder-event-acl 2026-11-11 02:25:44 -05:00
Joseph Doherty 489664d105 fix(acl): folder event verdict invalidation reaches orphaned items, decides on the live instance, skips ACL-off; alarm-bearing reference map (#826 review)
1. Orphaned subscriptions (session closed without deleting subs) have Session == null, so the public
   MonitoredNode2.InvalidatePermissionCacheForSession never reached their items: a cached allow survived a
   deploy, the moved alarm's events were queued and delivered on TransferSubscriptions. Each notifier's
   cache is now cleared whole through the SDK's private MonitoredNode2.InvalidatePermissionCaches
   (reflection, guard-tested; fallback = per-session drop + Remove/Add of session-less items).
2. The verdict is decided on the condition LIVE under the event's NodeId, not the event's own instance:
   the SDK key has no instance identity, so a replaced instance's late event cached a deny its successor
   inherited until the next invalidation.
3. Invalidation is skipped while enforcement is off (forced across an on/off authorizer transition) and is
   one O(cache) clear per node instead of a whole-cache scan per item.
4. TagReferencingEquipment carries alarm-bearing raw tags only (TagConfigIntent.Alarm); the snapshot adopts
   an OrdinalIgnoreCase set instead of copying it again.

Tests (each fails with its fix reverted): FolderEventVerdictInvalidationTests (orphan + deploy + transfer;
replaced instance's late event; ACL-off skip; SDK private-method guard), DeploymentArtifactScopePathTests
(alarm-bearing projection).
2026-11-11 02:25:24 -05:00
Joseph Doherty 8e1e73f93c fix(acl): per-event visibility for direct folder event items; generation-checked native wiring (#826)
Event items on an equipment / raw device folder were fed by the SDK's MonitoredNode2 fan-out with no ACL
decision, so after a deploy moved a scripted alarm (or dropped the reference projecting a native alarm into
an equipment) the OLD folder's subscribers kept receiving it - EventId included - until the rebuild landed,
indefinitely after a failed apply.

- OtOpcUaNodeManager re-implements INodeManager3 so ValidateEventRolePermissions (the SDK's per-event,
  per-item hook; base not virtual) adds IsNotifierEventVisibleTo: live condition instance, notifier still a
  legitimate notifier of it, and the #586/#808 Server-object rule (IsConditionVisibleTo over
  ConditionVisibilityScopes).
- The SDK memoizes that verdict per (item, event type, SourceNode): InvalidateFolderEventVerdicts runs on the
  authority/authorizer setters, RevalidateMonitoredItems (deploy + timer) and CompleteAddressSpaceApply.
- ConditionRefresh on direct items goes through RefreshDirectItems (base loop + the same decision).
- New generation field TagReferencingEquipment (RawPath -> EquipmentIds, from the artifact's
  UnsTagReferences via AclScopePathResolver.ResolveTagRawPath): a native alarm's wired equipment folder only
  counts (folder delivery AND Server-object scopes) while the current generation still references it.
- Secondary #808 edge: UNS variables wired UNS->Raw Organizes by AddReference are tracked and always placed
  as reference variables (an Area named like its equipment's id no longer narrows them).

Tests: UnsFolderScopeWireTests (moved alarm on a folder item + ConditionRefresh + rebuild; area named like
equipment id), NativeAlarmFolderEventAclWireTests (dropped reference: folder + Server object + refresh +
restore), DeploymentArtifactScopePathTests (projection). Rig/event tests now supply tag references.
2026-11-11 01:39:06 -05:00
Joseph Doherty 56e642239f test(opcua): i=11201 advertises DurationGood/DurationBad on the SQL backends (#820)
Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-11 01:30:51 -05:00
Joseph Doherty e7b485c0a2 feat(historian): serve DurationGood/DurationBad on the SQL backends; pin the #821 late-start facts (#820, #821)
#820: SqlServer + QuestDB now serve Part 13 DurationGood / DurationBad from the
same Good / Bad region totals TimeWeightedAggregator already computes for
PercentGood / PercentBad — reported in milliseconds (OPC UA Duration, the SDK's
unit), Uncertain time in neither (Mantis 0006166), same BadNoData / status /
Partial rules. AggregateFamilies.Served grows 17 -> 19, so i=11201 and the
up-front refusal follow automatically; Gateway still refuses both (explicit
served set, unchanged). Client.Shared AggregateType / mapper / CLI gain both.
The #796 oracle answers DurationGood through the Good-only subclass as well.
QualityMix conformance asserts both directly (Q and QP, hand values, ms, and
= PercentGood x interval), replaces the "refused up front" test, and adds
Duration* to the forward/reverse/truncated oracle comparisons.

#821 (facts only, no decision): SdkAggregateParityTests pins an Uncertain-first
late-start interval (QP over [0,20), both directions) against ours (Part 13
Total 163.96, TimeAverage 10.93), the frozen 1.5.378.182 calculators (188.96,
9.448), SDK 2.0.1's stock calculators (188.96, 9.448) and a Good-first control
(all 163.96); LiveAggregateLateStartFactsTests pins the same through the booted
server's runtime AggregateManager (live AggregateFilter) incl. DurationGood
15000 / PercentGood 75 there vs 8000 / 40 in HistoryRead (#809). QualityMix
adds the reverse late-start variant (reverse TW pin + reverse oracle windows).

Co-Authored-By: Claude <noreply@anthropic.com>
2026-11-11 01:28:54 -05:00
Joseph Doherty 40969e5c4b fix(opcua): failed sign-ins no longer lock a client out of anonymous sessions (#833)
OPC Foundation SDK 2.0.1's SessionManager lockout refused EVERY
activation (Anonymous included, before the token is read) from a client
with 5 failed identity validations in 60 s, for 5 minutes, keyed on cert
thumbprint else peer IP. Disable it (MaxFailedAuthenticationAttempts=0
on built and loaded configs) and enforce FailedCredentialLockout in the
identity-registry adapter instead: UserName activations only, keyed on
thumbprint+peer together, same 5/60s/300s defaults, configurable via
OpcUa:CredentialLockout.
2026-11-11 01:23:33 -05:00
Joseph Doherty e39a125069 fix(acl): close the #808 review findings — reference variables, owner folder chain, NUL keys, unknown ids (#808)
Review of af5c9744:
1. UNS reference variables (s=Area/Line/Equip/Eff) of a moved or renamed
   equipment stayed readable/writable under the OLD names' grants: they now
   resolve as ReferenceVariable and are authorized at their split path only
   while it equals their live equipment folder's placement (live chain ==
   generation chain) + one name; otherwise denied (Read and Write).
2. TryPlaceScriptedCondition now also requires the owner folder's live chain
   to match the generation (AuthorizeScriptedCondition gains ownerFolderChain),
   so a moved equipment's alarm/children/commands follow its folder.
3. Identifiers containing NUL are denied before the decision cache, keeping
   client ids disjoint from the NUL-prefixed resolved-scope keys (a client
   could otherwise poison a real folder's cached verdict for its key shard).
4. An id no live node holds is Unknown: placed at [\0unknown] so only
   Cluster / Namespace-uns grants decide it (a removed opaque id can no longer
   split onto a same-named narrow grant; narrow grantees get no NodeDeleted for
   removed UNS folders/vtags/conditions — documented); 4-segment
   reference-shaped ids keep their split.
5. A wire test drives placements from DeploymentArtifact.ParseDataPlaneAuthority.

Baseline updates: #797 owner tests (unit + wire) and Sdk2RepeatedAlarmAuthority
now install folder scopes; Sdk2HistoryAuthority's UNS alias used the RAW path
as its UNS id (never minted in production) and now carries EqA/HistoryAlias.
Each new guard was falsified (reverting it fails its test).
2026-11-10 23:44:11 -05:00
Joseph Doherty af5c9744b7 fix(acl): place opaque-id UNS folders, virtual tags and scripted conditions for every operation (#808)
UNS Area/Line/Equipment folders are minted under their opaque entity ids
(s=UA-/UL-/EQ-...), virtual tags under s=EQ-.../Name and scripted conditions
(+ #629 children) under s=<ScriptedAlarmId>[/...], while every UNS grant is
planted at a NAME path. DataPlaneAuthorizer split those ids, so with
Security:Acl:Enabled a narrow (Area/Line/Equipment) grant could not Browse,
Read, subscribe or HistoryRead them, and Server-object delivery never reached
it — so a narrow key never held the EventId Ack/Confirm/AddComment need.

- The generation carries UnsFolderScopes (folderId -> path + id chain), built
  by DeploymentArtifact from the same AclScopePathResolver as the grants; ids
  two entity kinds share are dropped; plumbed through IDataPlaneAuthoritySink.
- OtOpcUaNodeManager.ResolveUnsAclSubject reports live facts (folder id
  ancestry / scripted owner binding); attached by the Authorizer setter.
- Evaluate places the subject against the CURRENT generation before the
  decision cache, which now caches the walk keyed on the resolved scope.
  Folders require live chain == generation chain (a moved equipment is denied
  under old and new line until the rebuild). Owned nodes (vtags, conditions,
  children) get owner path + a reserved segment, so Tag grants and their
  Browse transit never expose them. Conditions share TryPlaceScriptedCondition
  with the #797 command gate.
- Server-object visibility of a scripted condition is decided on the
  condition alone, so a moved alarm cannot reach its old owner there.

Tests: UnsFolderScopeWireTests (opaque ids, end-to-end browse -> EventId ->
Acknowledge on an Equipment grant; sibling denied; Tag-only grant; moved alarm
and moved equipment stale windows). Rig tests now install folder scopes
explicitly (ServerEventRig.FolderScopes); the #797 recreate test deliberately
asserts the moved alarm is invisible to the Cluster observer in the window.
2026-11-10 23:12:46 -05:00
Joseph Doherty 4620e542e8 fix(acl): require the live scripted-alarm owner to match the generation's deployed owner (#797)
Review of 3d1b86b4: OpcUaPublishActor installs a new authority generation
before applying its address space, and an apply that throws keeps the old one.
A scripted alarm moved from equipment A to B therefore stayed commandable with
A's grant under B's generation (briefly before the rebuild, or indefinitely
after a failed apply).

The generation now carries ScriptedAlarmOwners (ScriptedAlarmId -> EquipmentId,
decoded by ParseDataPlaneAuthority from the artifact's ScriptedAlarms rows, the
same rows the composition materialises from). AuthorizeScriptedCondition denies
unless the node manager's live binding names the same owner as the generation:
a moved alarm is denied under the old owner's, the new owner's and a Cluster
grant until the address space re-binds it; an alarm the generation no longer
deploys is denied. Install/apply order unchanged.

Tests: window (a) generation moved / binding stale => both owners and Cluster
denied, then rebuild under the new owner => new owner allowed, old denied;
window (b) apply failed after install => denied across clock and further
generations, then a successful rebuild restores the new owner only; undeployed
alarm denied; artifact decode of the owner map.
2026-11-10 21:42:03 -05:00
Joseph Doherty 3d1b86b451 fix(acl): authorize scripted alarm commands at their owning equipment's scope (#797)
Scripted condition NodeIds are opaque ScriptedAlarmIds, so splitting them as a
topology path could never match an Equipment grant: a narrow equipment grant was
denied while a Cluster grant passed.

- OtOpcUaNodeManager binds each LIVE scripted condition instance to the
  EquipmentId it was materialised under (only when it hangs under that folder);
  dropped on remove / drop-recreate / equipment-subtree removal / rebuild; a
  same-id re-materialise under another equipment re-parents and re-binds.
- DataPlaneAuthoritySnapshot carries EquipmentScopePaths (EquipmentId ->
  [uns, Area, Line, Equipment]) decoded from the artifact by the same
  AclScopePathResolver call that plants Equipment grants.
- DataPlaneAuthorizer.AuthorizeScriptedCondition re-reads key, grant and
  generation per call (uncached) and evaluates at the owner path; unbound,
  replaced or unplaceable owners deny under every grant. No id-split or
  realm-root fallback.
- Native conditions (RawPath) and the ACL-off role gate are unchanged.
  NodeIds and AlarmCommand.AlarmId are unchanged.

Sdk2OpaqueScriptedScopeBaselineTests deliberately flipped: it pinned the denial
and now pins owner-grant allow / sibling deny / cluster allow. Follow-up #808
(folder ids + Server-object event visibility for narrow UNS grants).
2026-11-10 21:23:57 -05:00
Joseph Doherty f4054f6201 test: enforce late-slope restart and shutdown deadlines 2026-11-10 18:01:41 -05:00
Joseph Doherty 7f21c9aa64 test: capture the preserved late-slope assertion explicitly 2026-11-10 17:50:55 -05:00
Joseph Doherty 5ea6a23f1b test: implement fixed Linux late-slope diagnostic mode 2026-11-10 17:47:31 -05:00
Joseph Doherty 58f8d57f5a test: expose concurrent SDK2 host disposal completion race 2026-11-10 17:05:22 -05:00
Joseph Doherty 564f109143 test: align abandoned continuation count across close controls 2026-11-10 16:36:29 -05:00
Joseph Doherty 6737e367b4 test: pin closed authentication token rejection status 2026-11-10 16:33:09 -05:00
Joseph Doherty b5986c61d9 test: preserve bounded cleanup on close control failures 2026-11-10 16:31:05 -05:00
Joseph Doherty 235196beb2 test: add bounded SDK2 close ownership controls 2026-11-10 16:26:26 -05:00
Joseph Doherty d7891372f2 test(opcua): prove saturation observer runtime event delivery 2026-11-10 14:55:46 -05:00
Joseph Doherty 54a4ff2149 test(opcua): add fixed candidate saturation diagnosis with observer barriers 2026-11-10 14:55:46 -05:00
Joseph Doherty b57595cb4a test(opcua): distinguish rejected diagnostic samples from passing resource evidence 2026-11-10 13:31:07 -05:00
Joseph Doherty 484f3d3d2d test(opcua): latch rejected profiling budgets through bounded observation 2026-11-10 13:31:07 -05:00
Joseph Doherty 5575e014e7 test(opcua): permit bounded investigative profiling without a full soak claim 2026-11-10 13:31:07 -05:00
Joseph Doherty bfc61b745b test(opcua): retain managed and native growth diagnostics before soak gates 2026-11-10 13:31:07 -05:00
Joseph Doherty 47a29dee2b test: prove peer provenance and repeated alarm authority with baseline scope oracle 2026-11-10 12:50:19 -05:00
Joseph Doherty 642aefe35a test: bound and canonicalize lifecycle descriptor probes 2026-11-10 12:40:41 -05:00
Joseph Doherty 41e65f6a22 fix(opcua): restore alarm component reference after SDK creation 2026-11-10 12:14:35 -05:00
Joseph Doherty 8be3bb1734 test(opcua): measure soak observation after startup 2026-11-10 12:14:35 -05:00
Joseph Doherty a456d598ab test(opcua): retain manager references across soak restart 2026-11-10 12:14:35 -05:00
Joseph Doherty 73ee3ef20d test(opcua): add opt-in lifecycle and resource soak harness 2026-11-10 12:14:35 -05:00
Joseph Doherty 1840b5ccf6 test: verify live history authority and secure peer reactivation 2026-11-10 11:53:34 -05:00
Joseph Doherty 2541ef39f7 test: exercise baseline aggregate vectors through runtime registration 2026-11-10 11:46:29 -05:00
Joseph Doherty dc9e777bff test: prove trusted channels PKI and scoped audit compatibility 2026-11-10 11:43:59 -05:00
Joseph Doherty aac7c88417 test: migrate SDK 2.0 wire contracts and pin baseline aggregate vectors 2026-11-10 10:44:23 -05:00
Joseph Doherty 11a5c1d4e2 test: deflake load-sensitive tests (lmxopcua#769)
v2-ci / unit-tests (push) Has been cancelled
- NodeManagerLockTimeBenchmark: wall-clock budget enforced only with OTOPCUA_BENCH=1; default run keeps the state-correctness asserts and logs timings.
- OpcUaClientDriverWire host-status: signal (semaphore) wait that only accepts a non-Running state observed after the server is disposed.
- AbCip PollLatencyComparison: retry once on a fixture connection reset; p95 criterion enforced only with AB_LAT_ENFORCE=1.
- ScriptRunGuardTests: orphan scripts held by a ctx.Released signal instead of a 250 ms wall-clock spin that could finish inside the 60 ms budget under load; stuck-orphan wall-clock rule disabled in the tests that pin the strike counting.
- DependencyMuxReplayTests: split the inside-grace positive control (1 h grace) from the release test (control asserted before unregister), removing the 200 ms grace race.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-10 05:39:22 -05:00
Joseph Doherty f201f16fd4 fix(virtualtags): a disabled VirtualTag keeps its node and reads BadOutOfService (lmxopcua#787, owner decision)
v2-ci / unit-tests (push) Has been cancelled
Revises 963b0d66, which dropped a disabled VirtualTag from the runtime plan so a
bound client got BadNodeIdUnknown. Now the plan carries Enabled (part of value
equality): AddressSpaceComposer.Compose and DeploymentArtifact.BuildEquipmentVirtualTagPlans
keep the row with Enabled=false (byte-parity), the applier materialises the node as
normal, and VirtualTagHostActor spawns no VirtualTagActor for it but publishes
BadOutOfService (new OpcUaStatus constant) with a null value stamped at deploy, on
every apply. Enabled flips are node-irrelevant to the change classifier; enabled->disabled
stops the child, disabled->enabled resumes evaluation. Validator exemption and name
uniqueness unchanged. Scripted alarms keep their not-materialised convention.
Tests updated; new wire test DisabledVirtualTagWireTests. docs/VirtualTags.md updated.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-10 04:48:57 -05:00
Joseph Doherty 2da58d0360 build(deps): OPC Foundation SDK 1.5.378.106 -> 1.5.378.182 (lmxopcua#782 interim hop)
v2-ci / unit-tests (push) Has been cancelled
Behaviour-neutral hop: pin the SDK AggregateManager default to our
TreatUncertainAsBad=false (SDK .182 flipped it to true), parity guard now an
explicit deliberate-divergence assertion plus a booted-server check; adapt to
obsolete FindPredefinedNode(Type)/TraceConfiguration; Microsoft.Extensions.
Logging.Abstractions 10.0.7 -> 10.0.8 (SDK floor); stall wire test's late-flush
positive control is best-effort (.176 preserves publish queue ordering).

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 22:47:58 -05:00
Joseph Doherty a0c8b63c46 test(opcua-client): replace fixed delays in the ConditionRefresh wire test with ordering barriers (lmxopcua#764)
v2-ci / unit-tests (push) Has been cancelled
The 1500 ms pre-control and 500 ms trailing sleeps are gone. ConditionRefresh
completes server-side before SubscribeAlarmsAsync returns, so refresh events
queue ahead of the control Acknowledge; a trailing message-change barrier event
is projected and awaited (bounded 10 s poll) so any stray event must arrive
before it. The assertion is now the exact sequence [Acknowledge, Unspecified],
no weaker than before.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 18:15:13 -05:00
Joseph Doherty 380ec541c2 feat(cli): historyread --events reads event history over the wire (lmxopcua#776)
v2-ci / unit-tests (push) Has been cancelled
Item 1 of #776 (the B2 over-the-wire ask): Client.CLI had no way to issue a
HistoryReadEvents. `historyread --events` now sends ReadEventDetails to an
event notifier and prints one line per event in select-clause order.
--fields picks the select clauses (default EventId, EventType, Time,
SourceName, Severity, Message, ConditionName (on ConditionType), SourceNode);
--of-type adds an OfType where-clause. --events is exclusive with --modified /
--aggregate, and --fields / --of-type require it.

Client.Shared gains IOpcUaClientService/ISessionAdapter.HistoryReadEventsAsync
(default-implemented as NotSupported for other implementations) backed by the
real session adapter through HistoryReadPaging, so continuation points are
followed up to --max and a Bad node status is surfaced, not printed as empty.

Tests: CLI tests over the fake service (default filter, --fields/--of-type
filter, option conflicts); an over-the-wire test drives the shared client's
event read against the in-process server — the default fields come back
non-null, OfType filters, an invalid where-clause is BadEventFilterInvalid.
The other #776 items are decisions and are left open.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 16:17:24 -05:00
Joseph Doherty c802f0e7ed test(historian): wire test expects the Gateway's default aggregate set without TimeAverage/Total (lmxopcua#746)
v2-ci / unit-tests (push) Has been cancelled
The H2 merge (0b85c499) stopped advertising native Gateway TimeAverage/Total
until historiangw#27; it updated the Host test (4e76eeb5) but not
AdvertisedAggregateFunctionsWireTests, which failed 2/7 on master.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 16:17:22 -05:00
Joseph Doherty 29665c1872 feat(opcua): HistoryReadEvents projects EventType, ConditionName, SourceNode; honours the where-clause (lmxopcua#746)
HistoryReadEvents projected only EventId / SourceName / Time / ReceiveTime /
Message / Severity: a select clause asking for EventType, ConditionName or
SourceNode (what most generic alarm viewers ask for) got nulls, and the
event filter's where-clause (an OfType) was ignored.

- HistoricalEvent gains optional EventTypeName, ConditionName and AlarmId.
  SqlServer, QuestDB and Gateway event reads fill them from what their
  alarm writers already store (AlarmTypeName / AlarmName / AlarmId; the
  gateway event Type and its AlarmName / AlarmId properties).
- The node manager maps the type name to its Part 9 event type (unknown or
  non-event => AlarmConditionType), projects ConditionName, and resolves
  SourceNode to the materialised condition the alarm id names (the live
  events' SourceNode), else null.
- The where-clause is evaluated per event with the SDK content filter
  through an IFilterTarget (OfType via the type tree; other operators
  against the projected fields), after the page's cursor is taken, so
  paging is unchanged.

Tested in the node manager, over a real client session (the Client.CLI has
no `historyread --events` mode yet; filed as a follow-up), and by alarm
writer -> event read round trips on SqlServer and QuestDB.

Rebased from the unpushed remed/lane-H2 branch (originally authored 2026-10-22
in session_01Ub9hGmYLQvn9XETzw7CMsT) onto current master.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 15:40:47 -05:00
Joseph Doherty acc3057643 test: de-flake NodeManagerLockTimeBenchmark budget and OpcUaClientDriverWire host-status wait (lmxopcua#769)
v2-ci / unit-tests (push) Waiting to run
Benchmark wall-clock budget 1 s -> 5 s (measured 5-60 ms; still catches O(N^2)). Host-status wait is already a TCS signal; its 30 s ceiling is raised to 120 s so a starved box cannot time out before the keep-alive reports the loss.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 14:18:16 -05:00
Joseph Doherty d59e76dd9d feat(security): per-client pre-auth API-key miss budget; widen IOpcUaUserAuthenticator with the remote endpoint (lmxopcua#751)
The #733 miss budget (MissBurst / MissRefillPerSecond) was process-wide, because
the impersonation seam did not carry the client's address, so one noisy client
could drain it for everybody while the known-id set was unavailable.

- IOpcUaUserAuthenticator gains AuthenticateUserNameAsync(username, password,
  IPEndPoint? remoteEndpoint, ct) (default: ignore it and delegate); the server
  calls it. IApiKeyStore gains the matching FindAsync(..., IPAddress?, ...).
- The SDK (1.5.378) exposes no client address publicly. SecureChannelRemoteEndpoint
  reads it from the TCP listener's private channel map by reflection (through the
  protected TransportListeners, exposed by OtOpcUaSdkServer), keyed by the
  session's secure channel id. Fail-soft: null => process-wide accounting only.
- BoundedApiKeyStore charges a miss to the client's own bucket (keyed by IP
  address) and then to the process-wide one, which stays as the backstop. A
  refusal by either takes from neither; a hit refunds both. New options
  Security:ApiKeys:MissBurstPerEndpoint (10) / MissRefillPerSecondPerEndpoint (2),
  0 disables; telemetry outcome endpoint_miss_budget. At most 4096 addresses are
  tracked; idle buckets are pruned and an address beyond the cap is charged
  process-wide only.

Tests: BoundedApiKeyStorePerEndpointTests (noisy client vs quiet one, process-wide
backstop, refund + refill, off switch, authenticator forwards the address) and
over the wire ApiKeyMissBudgetPerEndpointTests (activation hands the authenticator
the loopback endpoint; real authenticator + bounded store refuse a client's 3rd
and 4th unknown key without a store read). Each new behaviour test fails with its
fix mutated out. Host.Tests 224/0, OpcUaServer.Tests 1019/1 (the one failure is the
wall-clock NodeManagerLockTimeBenchmarkTests under suite load; passes alone).
Docs: security.md.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 14:03:59 -05:00
Joseph Doherty 919009c5ef fix(ablegacy): stamp health from the injectable Clock; drop the redundant per-project TreatWarningsAsErrors (lmxopcua#768)
AbLegacyDriver stamped LastSuccessfulRead (init, read, write), the read's sample
timestamps and host-state change times from raw DateTime.UtcNow; only the backoff
path read the injectable Clock. All of them now read Clock(), so
NativePcccBridgeStatusHealthTests drives a manual clock (init at T0, read at T1)
and asserts LastSuccessfulRead == T1 exactly instead of spin-waiting for the wall
clock to pass the init stamp (#767). Without the driver change the 6 tests fail
(init stamp is wall-clock, not T0).

Directory.Build.props sets TreatWarningsAsErrors for every project since #766, so
the 75 per-csproj copies (64 src + 11 tests) are removed and the props comment
says it is now the only place. tools/mem-probe keeps its explicit opt-out.
Release build: 0 warnings, 0 errors; a planted CS0168 still fails the build in a
src project and in a test project that used to carry its own copy.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 13:40:07 -05:00
Joseph Doherty 8e8d4cdf13 fix(alarms): surface a refused native alarm ack synchronously, revert one that fails later (lmxopcua#760)
The native-ack path is fire-and-forget after the Part 9 Acknowledge returns, so
a Galaxy ack refused for lack of a credential (#749), or rejected by MXAccess,
left the client with Good and the condition showing Acknowledged while Galaxy
was never acked. Both options from the issue, layered:

1. Synchronous refusal for what the driver can decide without I/O. New optional
   IAlarmAcknowledgePreflight (Core.Abstractions); GalaxyDriver refuses an
   anonymous session when the driver has no AlarmAck fallback account.
   DriverHostActor publishes a condition NodeId -> owning-driver snapshot into
   NativeAlarmAckPreflightView (lock-free, volatile); the node manager's new
   NativeAlarmAckPreflight seam, consulted after the authz and Primary gates,
   returns BadUserAccessDenied with the reason - nothing routed, applied or
   reported. A keyed session is not pre-checked (its identity lives in the
   Secrets store, which must not be read under the SDK lock).

2. Revert for everything else. RouteAlarmAck carries the condition NodeId;
   DriverInstanceActor replies AlarmAckFailed on a refusal, a backend failure,
   a driver without an alarm source, or an ack dropped while connecting /
   reconnecting. DriverHostActor re-projects the condition unacknowledged via
   NativeAlarmProjector.TryRevertAcknowledge, but only while the local ack is
   still pending - any driver transition projected since then wins. A disabled
   or unspawned driver is not reverted (unchanged).

GatewayGalaxyAlarmAcknowledger now throws DriverOperationRefusedException on a
non-zero native hresult (wrong password, no ack permission) instead of only
warning, so that case reverts too; as a refusal it neither retries nor trips
the breaker.

Tests (each fails with its fix mutated out): projector revert/supersede,
DriverHostActor refused + failed ack -> unacked AlarmStateUpdate (successful
ack control), preflight view snapshot, node-manager preflight unit test,
over-the-wire ConditionMethodEventTests (BadUserAccessDenied, no route, no
event; positive control), Galaxy preflight + hresult refusal.
Docs: Galaxy.md, AlarmTracking.md, ScriptedAlarms.md, .claude/rules/alarms.md.

Claude-Session: https://claude.ai/code/session_01GT67AEHd2Acv1YPwGfXEoV
2026-11-09 13:12:17 -05:00