R07:L5 (Modbus half, former F2): ModbusTcpTransport builds the MBAP ADU in a
pooled buffer and reads the reply header into one per-transport buffer (sends are
single-flight under the gate). ModbusRtuOverTcpTransport writes its ADU into a
pooled buffer (ModbusRtuFraming.WriteAdu, byte-identical to BuildAdu), and
ReadResponsePduAsync reads and validates the whole frame in one pooled buffer
instead of five arrays. Only the returned PDU is allocated. The exchange stays one
async method: splitting it cost a state-machine box that ate the saving. Scratch
A/B per op: RTU deframe 352 -> 184 B, RTU send 640 -> 408 B, TCP send 864 -> 800 B;
timings within noise; Driver.Modbus.Tests 2 s before and after. NormalizeWordOrder
lives in ModbusDriver (not a transport) and is left alone.
Refs #747
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
H4: exception 01/02/03 (and undecodable data) are device refusals - per-tag
Bad with a once-per-tag Warning, no Degraded, and they advance
LastSuccessfulRead (the device answered), so an all-refused driver no longer
trips the 90 s watchdog. 04/05/06 still degrade (answered); 0A/0B degrade
without advancing. Health is one worst-wins write per batch instead of
last-writer-wins per tag. A comms failure on one unit fails the rest of
that unit's batch fast; an unreachable endpoint fails the whole batch fast.
H7: write transport failures map to BadCommunicationError, value overflow and
array length mismatch to BadOutOfRange, conversion failures to
BadTypeMismatch; writes report write-side health (a good write or a refusal
clears a write-side Degraded; a good read does not).
Lifecycle: every health write and the transport/table publish carry a
generation; a superseded init releases its transport and publishes nothing,
a read straddling a re-init cannot degrade the new transport, and the
shutdown's final write cannot clobber a newer init. The tag table is
build-and-swapped (re-init no longer merges into the old table). Teardown
joins the probe/re-probe loops (bounded); a probe answer advances
LastSuccessfulRead and an exception PDU from the device counts as Running.
Transports latch dispose atomically and never reconnect after it.
Refs #741
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
P3: a torn-down socket is re-dialled inside the gate (one attempt per backoff
window) instead of failing fast with 'Transport not connected' until the 90 s
comms-loss watchdog re-initialised the driver.
L3: ConnectAsync disposes the previous/failed TcpClient, DNS runs under the
per-op timeout, and the reconnect never sleeps inside the gate (the old
10-attempt backoff held it for ~81 s).
H9: an MBAP response with no PDU, or an exception PDU with no code, is a
TruncatedFrame desync rather than an IndexOutOfRangeException.
Refs #741
Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
Clears CommentChecker findings in src/ (3,280 -> 209, the remainder being false
positives like PLC-5/IEEE-754/M0.0) by adding missing summaries/params/returns,
normalising inheritdoc usage, and removing Gitea/review tracking IDs while keeping
the rationale they annotated. Comment-only: comment-stripped sources are identical
to the parent commit.