fix(modbus): refusals are per-tag Bad, batch health, generation-stamped lifecycle, write status mapping
H4: exception 01/02/03 (and undecodable data) are device refusals - per-tag Bad with a once-per-tag Warning, no Degraded, and they advance LastSuccessfulRead (the device answered), so an all-refused driver no longer trips the 90 s watchdog. 04/05/06 still degrade (answered); 0A/0B degrade without advancing. Health is one worst-wins write per batch instead of last-writer-wins per tag. A comms failure on one unit fails the rest of that unit's batch fast; an unreachable endpoint fails the whole batch fast. H7: write transport failures map to BadCommunicationError, value overflow and array length mismatch to BadOutOfRange, conversion failures to BadTypeMismatch; writes report write-side health (a good write or a refusal clears a write-side Degraded; a good read does not). Lifecycle: every health write and the transport/table publish carry a generation; a superseded init releases its transport and publishes nothing, a read straddling a re-init cannot degrade the new transport, and the shutdown's final write cannot clobber a newer init. The tag table is build-and-swapped (re-init no longer merges into the old table). Teardown joins the probe/re-probe loops (bounded); a probe answer advances LastSuccessfulRead and an exception PDU from the device counts as Running. Transports latch dispose atomically and never reconnect after it. Refs #741 Claude-Session: https://claude.ai/code/session_01Ub9hGmYLQvn9XETzw7CMsT
This commit is contained in:
@@ -0,0 +1,17 @@
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus;
|
||||
|
||||
/// <summary>
|
||||
/// The device answered with well-framed data the tag's codec cannot represent (a non-BCD nibble in a
|
||||
/// BCD register, for example). The device is reachable, so this is a per-tag
|
||||
/// <c>BadDecodingError</c> with a once-per-tag Warning — never a comms fault, never a health write.
|
||||
/// </summary>
|
||||
public sealed class ModbusDecodeException : Exception
|
||||
{
|
||||
/// <summary>Initializes a new instance of the <see cref="ModbusDecodeException"/> class.</summary>
|
||||
/// <param name="message">A human-readable description.</param>
|
||||
/// <param name="inner">The codec's own exception.</param>
|
||||
public ModbusDecodeException(string message, Exception? inner = null)
|
||||
: base(message, inner)
|
||||
{
|
||||
}
|
||||
}
|
||||
@@ -43,7 +43,33 @@ public sealed class ModbusDriver
|
||||
|
||||
// v3 authored-tag table, keyed by RawPath (the tag identity + driver wire reference). RawPath is
|
||||
// case-sensitive ordinal. Built in InitializeAsync from _options.RawTags via the pure mapper.
|
||||
private readonly Dictionary<string, ModbusTagDefinition> _tagsByRawPath = new(StringComparer.Ordinal);
|
||||
// BUILD-AND-SWAP: a fresh dictionary is built off to the side and published by reference
|
||||
// (Volatile.Write, under _stateLock with the generation check); it is never mutated or .Clear()ed
|
||||
// in place, because retained poll loops read it concurrently across a re-initialize.
|
||||
private Dictionary<string, ModbusTagDefinition> _tagsByRawPath = new(StringComparer.Ordinal);
|
||||
|
||||
/// <summary>
|
||||
/// Lifecycle generation. Every InitializeAsync / ShutdownAsync bumps it under
|
||||
/// <see cref="_stateLock"/>; every health write and every table/transport publish carries the
|
||||
/// generation it was computed under and is DROPPED once the generation has moved on — so a
|
||||
/// superseded (abandoned) initialize can never publish over a newer one, a read that straddled a
|
||||
/// re-initialize cannot write health about the new transport, and a shutdown's final health
|
||||
/// write cannot clobber a newer init.
|
||||
/// </summary>
|
||||
private int _generation;
|
||||
|
||||
/// <summary>Guards <see cref="_generation"/>, the transport/table publish and the health fields.</summary>
|
||||
private readonly object _stateLock = new();
|
||||
|
||||
// Health is composed from two independent sides so a good write clears only a WRITE-side
|
||||
// Degraded (and a good read only a read-side one). LastSuccessfulRead advances on any evidence the
|
||||
// device answered — a good read, a good write, a refusal, or a probe answer.
|
||||
private string? _readFault;
|
||||
private string? _writeFault;
|
||||
|
||||
// Once-per-tag Warning for deterministic device refusals (exception 01/02/03, undecodable data).
|
||||
// Replaced (never cleared in place) on every table publish.
|
||||
private ConcurrentDictionary<string, byte> _refusalWarned = new(StringComparer.Ordinal);
|
||||
|
||||
// Resolves a read/write/subscribe RawPath reference to its tag definition via a single hit on the
|
||||
// authored _tagsByRawPath table (v3: the reference is always a RawPath; a miss is a miss).
|
||||
@@ -87,6 +113,11 @@ public sealed class ModbusDriver
|
||||
private IModbusTransport? _transport;
|
||||
private CancellationTokenSource? _probeCts;
|
||||
private CancellationTokenSource? _reprobeCts;
|
||||
private Task? _probeTask;
|
||||
private Task? _reprobeTask;
|
||||
|
||||
/// <summary>Bounded join on the probe / re-probe loops at teardown — they honour their token, so this is a backstop.</summary>
|
||||
private static readonly TimeSpan BackgroundLoopJoinTimeout = TimeSpan.FromSeconds(2);
|
||||
|
||||
/// <summary>
|
||||
/// Guards <see cref="InitializeAsync"/> / <see cref="ReinitializeAsync"/> /
|
||||
@@ -105,7 +136,7 @@ public sealed class ModbusDriver
|
||||
/// (a connect that never returns) must not turn shutdown or dispose into a hang — past the
|
||||
/// timeout they tear down anyway, which is the lesser evil of the two.
|
||||
/// </summary>
|
||||
private static readonly TimeSpan LifecycleGateTimeout = TimeSpan.FromSeconds(10);
|
||||
internal TimeSpan LifecycleGateTimeout { get; set; } = TimeSpan.FromSeconds(10);
|
||||
|
||||
private DriverHealth _health = new(DriverState.Unknown, null, null);
|
||||
|
||||
@@ -152,7 +183,7 @@ public sealed class ModbusDriver
|
||||
_driverInstanceId = driverInstanceId;
|
||||
_logger = logger ?? NullLogger<ModbusDriver>.Instance;
|
||||
_resolver = new EquipmentTagRefResolver<ModbusTagDefinition>(
|
||||
r => _tagsByRawPath.TryGetValue(r, out var t) ? t : null);
|
||||
r => Volatile.Read(ref _tagsByRawPath).TryGetValue(r, out var t) ? t : null);
|
||||
_transportFactory = transportFactory
|
||||
?? (o => ModbusTransportFactory.Create(o));
|
||||
_poll = new PollGroupEngine(
|
||||
@@ -208,9 +239,151 @@ public sealed class ModbusDriver
|
||||
internal void HandlePollError(Exception ex)
|
||||
{
|
||||
_logger.LogWarning(ex, "Modbus poll reader failed. Driver={DriverInstanceId}", _driverInstanceId);
|
||||
var current = ReadHealth();
|
||||
if (current.State != DriverState.Faulted)
|
||||
WriteHealth(new DriverHealth(DriverState.Degraded, current.LastSuccessfulRead, ex.Message));
|
||||
lock (_stateLock)
|
||||
{
|
||||
// Lifecycle-owned states are left alone: Faulted is a stronger, config-level signal, and an
|
||||
// Initializing/Unknown driver has no transport for a poll to have failed against — the
|
||||
// failure is the re-initialize window itself, which the lifecycle reports on its own.
|
||||
var current = _health;
|
||||
if (current.State is DriverState.Faulted or DriverState.Initializing or DriverState.Unknown) return;
|
||||
_readFault = ex.Message;
|
||||
PublishComposedHealthLocked(current.LastSuccessfulRead);
|
||||
}
|
||||
}
|
||||
|
||||
// ---- health composition ----
|
||||
|
||||
/// <summary>Which half of the driver a batch outcome came from.</summary>
|
||||
private enum HealthSide { Read, Write }
|
||||
|
||||
/// <summary>
|
||||
/// Per-batch accounting: did the device answer anything, did a comms fault happen, and which units
|
||||
/// (or the whole endpoint) must the rest of this batch fail fast against.
|
||||
/// </summary>
|
||||
private sealed class BatchOutcome
|
||||
{
|
||||
public bool Answered;
|
||||
public string? CommsFault;
|
||||
public bool EndpointDown;
|
||||
private HashSet<byte>? _failedUnits;
|
||||
|
||||
public void FailUnit(byte unit) => (_failedUnits ??= []).Add(unit);
|
||||
|
||||
public bool IsFailedFast(byte unit) => EndpointDown || (_failedUnits?.Contains(unit) ?? false);
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Applies one batch's outcome to the driver health, under <see cref="_stateLock"/>, and only when
|
||||
/// <paramref name="generation"/> is still current. A batch that touched no device (every reference
|
||||
/// unknown, every write refused before the wire) changes nothing.
|
||||
/// </summary>
|
||||
private void ReportOutcome(int generation, HealthSide side, BatchOutcome batch, DateTime now)
|
||||
{
|
||||
if (!batch.Answered && batch.CommsFault is null) return;
|
||||
lock (_stateLock)
|
||||
{
|
||||
if (generation != _generation) return;
|
||||
var current = _health;
|
||||
if (current.State is DriverState.Faulted or DriverState.Initializing or DriverState.Unknown) return;
|
||||
if (side == HealthSide.Read) _readFault = batch.CommsFault;
|
||||
else _writeFault = batch.CommsFault;
|
||||
PublishComposedHealthLocked(batch.Answered ? now : current.LastSuccessfulRead);
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>Writes Healthy/Degraded from the two fault sides. Caller holds <see cref="_stateLock"/>.</summary>
|
||||
private void PublishComposedHealthLocked(DateTime? lastSuccessfulRead)
|
||||
{
|
||||
var fault = _readFault ?? _writeFault;
|
||||
WriteHealth(fault is null
|
||||
? new DriverHealth(DriverState.Healthy, lastSuccessfulRead, null)
|
||||
: new DriverHealth(DriverState.Degraded, lastSuccessfulRead, fault));
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// A probe answer proves the device is reachable: advance <c>LastSuccessfulRead</c> without
|
||||
/// touching either fault side (it says nothing about the tags).
|
||||
/// </summary>
|
||||
private void NoteDeviceAnswered(int generation)
|
||||
{
|
||||
lock (_stateLock)
|
||||
{
|
||||
if (generation != _generation) return;
|
||||
var current = _health;
|
||||
if (current.State is not (DriverState.Healthy or DriverState.Degraded)) return;
|
||||
WriteHealth(current with { LastSuccessfulRead = DateTime.UtcNow });
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>Lifecycle health write, dropped when <paramref name="generation"/> has been superseded.</summary>
|
||||
private void WriteLifecycleHealth(int generation, DriverHealth health)
|
||||
{
|
||||
lock (_stateLock)
|
||||
{
|
||||
if (generation != _generation) return;
|
||||
_readFault = null;
|
||||
_writeFault = null;
|
||||
WriteHealth(health);
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Classifies one failed read/write against the health contract and returns the per-tag status:
|
||||
/// <list type="bullet">
|
||||
/// <item>Exception 01/02/03 — a deterministic REFUSAL: the device answered; per-tag Bad, a
|
||||
/// once-per-tag Warning, no Degraded (it used to latch Degraded and, if every tag refused,
|
||||
/// trip the 90 s watchdog against a reachable device).</item>
|
||||
/// <item>Exception 04/05/06 — the device answered but is not serving: Degraded, answered.</item>
|
||||
/// <item>Exception 0A/0B (and unknown codes) — the gateway answered for a target that did not:
|
||||
/// Degraded, not answered; 0B fails the rest of that unit's batch fast.</item>
|
||||
/// <item>Undecodable data — the device answered with a value we cannot represent: per-tag
|
||||
/// <c>BadDecodingError</c>, once-per-tag Warning, no Degraded.</item>
|
||||
/// <item>No socket / throttled reconnect — the endpoint is down: Degraded, the rest of the
|
||||
/// batch fails fast.</item>
|
||||
/// <item>Any other transport failure (timeout, desync, EOF) — Degraded; the rest of that
|
||||
/// unit's batch fails fast instead of serialising N timeouts.</item>
|
||||
/// </list>
|
||||
/// </summary>
|
||||
private uint ClassifyFailure(Exception ex, byte unit, string tagRef, BatchOutcome batch, bool isWrite)
|
||||
{
|
||||
switch (ex)
|
||||
{
|
||||
case ModbusException mex when IsRefusalCode(mex.ExceptionCode):
|
||||
batch.Answered = true;
|
||||
WarnRefusalOnce(tagRef, isWrite, $"exception 0x{mex.ExceptionCode:X2} (fc 0x{mex.FunctionCode:X2})");
|
||||
return MapModbusExceptionToStatus(mex.ExceptionCode);
|
||||
case ModbusException mex when mex.ExceptionCode is 0x04 or 0x05 or 0x06:
|
||||
batch.Answered = true;
|
||||
batch.CommsFault ??= mex.Message;
|
||||
return MapModbusExceptionToStatus(mex.ExceptionCode);
|
||||
case ModbusException mex:
|
||||
batch.CommsFault ??= mex.Message;
|
||||
if (mex.ExceptionCode == 0x0B) batch.FailUnit(unit);
|
||||
return MapModbusExceptionToStatus(mex.ExceptionCode);
|
||||
case ModbusDecodeException dex:
|
||||
batch.Answered = true;
|
||||
WarnRefusalOnce(tagRef, isWrite, dex.Message);
|
||||
return StatusBadDecodingError;
|
||||
case ModbusTransportUnavailableException or ObjectDisposedException or System.Net.Sockets.SocketException:
|
||||
batch.CommsFault ??= ex.Message;
|
||||
batch.EndpointDown = true;
|
||||
return StatusBadCommunicationError;
|
||||
default:
|
||||
batch.CommsFault ??= ex.Message;
|
||||
batch.FailUnit(unit);
|
||||
return StatusBadCommunicationError;
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>Exception 01 Illegal Function / 02 Illegal Data Address / 03 Illegal Data Value — the device refused the request.</summary>
|
||||
internal static bool IsRefusalCode(byte exceptionCode) => exceptionCode is 0x01 or 0x02 or 0x03;
|
||||
|
||||
private void WarnRefusalOnce(string tagRef, bool isWrite, string detail)
|
||||
{
|
||||
if (!Volatile.Read(ref _refusalWarned).TryAdd((isWrite ? "w:" : "r:") + tagRef, 0)) return;
|
||||
_logger.LogWarning(
|
||||
"Modbus device refused {Operation} of tag {RawPath}: {Detail}. The tag reads/writes Bad; driver health is unaffected (the device answered). Driver={DriverInstanceId}",
|
||||
isWrite ? "a write" : "a read", tagRef, detail, _driverInstanceId);
|
||||
}
|
||||
|
||||
// <summary>
|
||||
@@ -310,11 +483,26 @@ public sealed class ModbusDriver
|
||||
/// <summary>The gate-held body of <see cref="InitializeAsync"/>.</summary>
|
||||
private async Task InitializeCoreAsync(string driverConfigJson, CancellationToken cancellationToken)
|
||||
{
|
||||
WriteHealth(new DriverHealth(DriverState.Initializing, null, null));
|
||||
// Claim a new generation and take the previous transport out of service atomically: any read or
|
||||
// write that captured the old generation can no longer write health, and nothing can capture the
|
||||
// old transport from here on.
|
||||
int generation;
|
||||
IModbusTransport? previous;
|
||||
lock (_stateLock)
|
||||
{
|
||||
generation = ++_generation;
|
||||
previous = _transport;
|
||||
_transport = null;
|
||||
_readFault = null;
|
||||
_writeFault = null;
|
||||
WriteHealth(new DriverHealth(DriverState.Initializing, null, null));
|
||||
}
|
||||
|
||||
IModbusTransport? transport = null;
|
||||
try
|
||||
{
|
||||
// Release whatever a PREVIOUS initialize published before building the replacements. All
|
||||
// three fields assigned below (_transport, _probeCts, _reprobeCts) were simply overwritten,
|
||||
// fields assigned below (_transport, _probeCts, _reprobeCts) were simply overwritten,
|
||||
// so a second initialize on a live driver stranded a connected transport plus two running
|
||||
// background loops that no later dispose could reach. The IDriver contract lets a
|
||||
// caller re-initialise a live driver without ShutdownAsync, and DriverInstanceActor's retry tick
|
||||
@@ -323,20 +511,9 @@ public sealed class ModbusDriver
|
||||
// every ACTIVE SUBSCRIPTION — and nothing re-subscribes them afterwards, because a
|
||||
// mid-life re-initialize is not a shutdown the OPC UA layer knows to re-drive. A caller
|
||||
// that genuinely wants the subscriptions gone calls ShutdownAsync. A first initialize
|
||||
// sees three nulls, so this block is a no-op on the initial call.
|
||||
try { _probeCts?.Cancel(); } catch { }
|
||||
_probeCts?.Dispose();
|
||||
_probeCts = null;
|
||||
|
||||
try { _reprobeCts?.Cancel(); } catch { }
|
||||
_reprobeCts?.Dispose();
|
||||
_reprobeCts = null;
|
||||
|
||||
if (_transport is not null)
|
||||
{
|
||||
await _transport.DisposeAsync().ConfigureAwait(false);
|
||||
_transport = null;
|
||||
}
|
||||
// sees nulls, so this block is a no-op on the initial call.
|
||||
await StopBackgroundLoopsAsync().ConfigureAwait(false);
|
||||
if (previous is not null) await previous.DisposeAsync().ConfigureAwait(false);
|
||||
|
||||
// re-parse the supplied DriverConfig so a config change delivered through the IDriver
|
||||
// contract is honoured. Without this the driver keeps serving the options it was CONSTRUCTED
|
||||
@@ -345,17 +522,19 @@ public sealed class ModbusDriver
|
||||
if (HasConfigBody(driverConfigJson))
|
||||
_options = ModbusDriverFactoryExtensions.ParseOptions(_driverInstanceId, driverConfigJson);
|
||||
|
||||
_transport = _transportFactory(_options);
|
||||
await _transport.ConnectAsync(cancellationToken).ConfigureAwait(false);
|
||||
// Build the RawPath → definition table from the authored raw tags. Each entry's TagConfig
|
||||
// blob is mapped by the pure factory; the entry's WriteIdempotent flag is threaded onto the
|
||||
// def (it lives on the RawTagEntry, not inside the blob). A mapper miss is skipped (logged),
|
||||
// never thrown — a bad tag must not fail the whole driver init.
|
||||
transport = _transportFactory(_options);
|
||||
await transport.ConnectAsync(cancellationToken).ConfigureAwait(false);
|
||||
|
||||
// Build the RawPath → definition table OFF TO THE SIDE from the authored raw tags. Each
|
||||
// entry's TagConfig blob is mapped by the pure factory; the entry's WriteIdempotent flag is
|
||||
// threaded onto the def (it lives on the RawTagEntry, not inside the blob). A mapper miss is
|
||||
// skipped (logged), never thrown — a bad tag must not fail the whole driver init.
|
||||
var table = new Dictionary<string, ModbusTagDefinition>(StringComparer.Ordinal);
|
||||
_skippedTags.BeginRebuild(_options.RawTags.Count);
|
||||
foreach (var entry in _options.RawTags)
|
||||
{
|
||||
if (ModbusTagDefinitionFactory.FromTagConfig(entry.TagConfig, entry.RawPath, out var def))
|
||||
_tagsByRawPath[entry.RawPath] = def with { WriteIdempotent = entry.WriteIdempotent };
|
||||
table[entry.RawPath] = def with { WriteIdempotent = entry.WriteIdempotent };
|
||||
else
|
||||
{
|
||||
_skippedTags.Skip(entry.RawPath, "TagConfig did not map to a definition");
|
||||
@@ -365,30 +544,76 @@ public sealed class ModbusDriver
|
||||
}
|
||||
}
|
||||
_skippedTags.Commit();
|
||||
WriteHealth(new DriverHealth(DriverState.Healthy, DateTime.UtcNow, null));
|
||||
|
||||
// PR 23: kick off the probe loop once the transport is up. Initial state stays
|
||||
// Unknown until the first probe tick succeeds — avoids broadcasting a premature
|
||||
// Running transition before any register round-trip has happened.
|
||||
if (_options.Probe.Enabled)
|
||||
// Publish transport + table + Healthy as ONE generation-checked step. A superseded attempt
|
||||
// (a shutdown/initialize ran while this one was abandoned mid-connect) publishes nothing and
|
||||
// releases its own transport.
|
||||
lock (_stateLock)
|
||||
{
|
||||
_probeCts = new CancellationTokenSource();
|
||||
_ = Task.Run(() => ProbeLoopAsync(_probeCts.Token), _probeCts.Token);
|
||||
}
|
||||
if (generation != _generation)
|
||||
throw new OperationCanceledException(
|
||||
"Modbus initialize was superseded by a later lifecycle operation; its transport was released");
|
||||
_transport = transport;
|
||||
Volatile.Write(ref _tagsByRawPath, table);
|
||||
Volatile.Write(ref _refusalWarned, new ConcurrentDictionary<string, byte>(StringComparer.Ordinal));
|
||||
WriteHealth(new DriverHealth(DriverState.Healthy, DateTime.UtcNow, null));
|
||||
|
||||
if (_options.AutoProhibitReprobeInterval is not null)
|
||||
{
|
||||
_reprobeCts = new CancellationTokenSource();
|
||||
_ = Task.Run(() => ReprobeLoopAsync(_reprobeCts.Token), _reprobeCts.Token);
|
||||
// PR 23: kick off the probe loop once the transport is up. Initial state stays
|
||||
// Unknown until the first probe tick succeeds — avoids broadcasting a premature
|
||||
// Running transition before any register round-trip has happened. Started inside the
|
||||
// generation-checked publish so a teardown that bypassed the lifecycle gate can never
|
||||
// run between the publish and the loop start and strand a loop.
|
||||
if (_options.Probe.Enabled)
|
||||
{
|
||||
var cts = new CancellationTokenSource();
|
||||
var probeTransport = transport;
|
||||
_probeCts = cts;
|
||||
_probeTask = Task.Run(() => ProbeLoopAsync(generation, probeTransport, cts.Token), cts.Token);
|
||||
}
|
||||
|
||||
if (_options.AutoProhibitReprobeInterval is not null)
|
||||
{
|
||||
var cts = new CancellationTokenSource();
|
||||
_reprobeCts = cts;
|
||||
_reprobeTask = Task.Run(() => ReprobeLoopAsync(cts.Token), cts.Token);
|
||||
}
|
||||
}
|
||||
transport = null; // published — owned by the driver now
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
WriteHealth(new DriverHealth(DriverState.Faulted, null, ex.Message));
|
||||
// A failed attempt releases the transport it built — it is never left half-published.
|
||||
if (transport is not null)
|
||||
{
|
||||
try { await transport.DisposeAsync().ConfigureAwait(false); } catch { }
|
||||
}
|
||||
WriteLifecycleHealth(generation, new DriverHealth(DriverState.Faulted, null, ex.Message));
|
||||
throw;
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>Cancels, bounded-joins and disposes the probe and re-probe loops. Idempotent.</summary>
|
||||
private async Task StopBackgroundLoopsAsync()
|
||||
{
|
||||
var probeCts = _probeCts;
|
||||
var reprobeCts = _reprobeCts;
|
||||
var tasks = new[] { _probeTask, _reprobeTask }.Where(t => t is not null).Cast<Task>().ToArray();
|
||||
_probeCts = null;
|
||||
_reprobeCts = null;
|
||||
_probeTask = null;
|
||||
_reprobeTask = null;
|
||||
|
||||
try { probeCts?.Cancel(); } catch { }
|
||||
try { reprobeCts?.Cancel(); } catch { }
|
||||
if (tasks.Length > 0)
|
||||
{
|
||||
try { await Task.WhenAll(tasks).WaitAsync(BackgroundLoopJoinTimeout).ConfigureAwait(false); }
|
||||
catch { /* a loop that ignores its token is abandoned, never awaited forever */ }
|
||||
}
|
||||
probeCts?.Dispose();
|
||||
reprobeCts?.Dispose();
|
||||
}
|
||||
|
||||
/// <inheritdoc />
|
||||
public async Task ReinitializeAsync(string driverConfigJson, CancellationToken cancellationToken)
|
||||
{
|
||||
@@ -435,9 +660,17 @@ public sealed class ModbusDriver
|
||||
/// <see cref="ReinitializeAsync"/>.</summary>
|
||||
private async Task ShutdownCoreAsync()
|
||||
{
|
||||
var lastRead = ReadHealth().LastSuccessfulRead;
|
||||
int generation;
|
||||
DateTime? lastRead;
|
||||
lock (_stateLock)
|
||||
{
|
||||
// A shutdown is a lifecycle operation too: it supersedes any in-flight (abandoned) initialize,
|
||||
// and its own final write below is dropped if a NEWER initialize started meanwhile.
|
||||
generation = ++_generation;
|
||||
lastRead = _health.LastSuccessfulRead;
|
||||
}
|
||||
await TeardownAsync().ConfigureAwait(false);
|
||||
WriteHealth(new DriverHealth(DriverState.Unknown, lastRead, null));
|
||||
WriteLifecycleHealth(generation, new DriverHealth(DriverState.Unknown, lastRead, null));
|
||||
}
|
||||
|
||||
/// <inheritdoc />
|
||||
@@ -489,57 +722,83 @@ public sealed class ModbusDriver
|
||||
public async Task<IReadOnlyList<DataValueSnapshot>> ReadAsync(
|
||||
IReadOnlyList<string> fullReferences, CancellationToken cancellationToken)
|
||||
{
|
||||
var transport = RequireTransport();
|
||||
var (generation, transport, table) = CaptureLifecycle();
|
||||
var now = DateTime.UtcNow;
|
||||
var results = new DataValueSnapshot[fullReferences.Count];
|
||||
var batch = new BatchOutcome();
|
||||
|
||||
var coalesced = _options.MaxReadGap > 0
|
||||
? await ReadCoalescedAsync(transport, fullReferences, results, now, cancellationToken).ConfigureAwait(false)
|
||||
? await ReadCoalescedAsync(transport, table, fullReferences, results, now, batch, cancellationToken).ConfigureAwait(false)
|
||||
: new HashSet<int>();
|
||||
|
||||
for (var i = 0; i < fullReferences.Count; i++)
|
||||
{
|
||||
if (coalesced.Contains(i)) continue;
|
||||
if (!_resolver.TryResolve(fullReferences[i], out var tag))
|
||||
if (!table.TryGetValue(fullReferences[i], out var tag))
|
||||
{
|
||||
results[i] = new DataValueSnapshot(null, StatusBadNodeIdUnknown, null, now);
|
||||
continue;
|
||||
}
|
||||
var unit = ResolveUnitId(tag);
|
||||
if (batch.IsFailedFast(unit))
|
||||
{
|
||||
// Fail fast: this unit (or the whole endpoint) already failed at the transport this batch;
|
||||
// paying the same timeout once per remaining tag would stall the poll N-fold.
|
||||
results[i] = new DataValueSnapshot(null, StatusBadCommunicationError, null, now);
|
||||
continue;
|
||||
}
|
||||
try
|
||||
{
|
||||
var value = await ReadOneAsync(transport, tag, cancellationToken).ConfigureAwait(false);
|
||||
results[i] = new DataValueSnapshot(value, 0u, now, now);
|
||||
WriteHealth(new DriverHealth(DriverState.Healthy, now, null));
|
||||
batch.Answered = true;
|
||||
|
||||
// Invalidate the WriteOnChangeOnly cache when the read returns a different value
|
||||
// — typically an HMI-side or PLC-internal change. Without this, a setpoint
|
||||
// tweaked at the panel could be silently re-suppressed when our client tried
|
||||
// to restore it.
|
||||
if (_options.WriteOnChangeOnly)
|
||||
{
|
||||
lock (_lastWrittenLock)
|
||||
{
|
||||
if (_lastWrittenByRef.TryGetValue(fullReferences[i], out var prev) && !Equals(prev, value))
|
||||
_lastWrittenByRef.Remove(fullReferences[i]);
|
||||
}
|
||||
}
|
||||
InvalidateWriteCacheIfDiverged(fullReferences[i], value);
|
||||
}
|
||||
catch (ModbusException mex)
|
||||
catch (OperationCanceledException) when (cancellationToken.IsCancellationRequested)
|
||||
{
|
||||
results[i] = new DataValueSnapshot(null, MapModbusExceptionToStatus(mex.ExceptionCode), null, now);
|
||||
WriteHealth(new DriverHealth(DriverState.Degraded, ReadHealth().LastSuccessfulRead, mex.Message));
|
||||
throw;
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
// Non-Modbus-layer failure: socket dropped, timeout, malformed response. Surface
|
||||
// as communication error so callers can distinguish it from tag-level faults.
|
||||
results[i] = new DataValueSnapshot(null, StatusBadCommunicationError, null, now);
|
||||
WriteHealth(new DriverHealth(DriverState.Degraded, ReadHealth().LastSuccessfulRead, ex.Message));
|
||||
results[i] = new DataValueSnapshot(null, ClassifyFailure(ex, unit, fullReferences[i], batch, isWrite: false), null, now);
|
||||
}
|
||||
}
|
||||
|
||||
// ONE health write per batch, worst-wins over the batch, generation-checked. It used to be
|
||||
// last-writer-wins per tag, so health flapped with tag order.
|
||||
ReportOutcome(generation, HealthSide.Read, batch, now);
|
||||
return results;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Captures the generation, transport and tag table a read/write batch runs against, atomically
|
||||
/// with respect to a lifecycle publish.
|
||||
/// </summary>
|
||||
private (int Generation, IModbusTransport Transport, Dictionary<string, ModbusTagDefinition> Table) CaptureLifecycle()
|
||||
{
|
||||
lock (_stateLock)
|
||||
{
|
||||
var transport = _transport ?? throw new InvalidOperationException("ModbusDriver not initialized");
|
||||
return (_generation, transport, _tagsByRawPath);
|
||||
}
|
||||
}
|
||||
|
||||
/// <summary>Runs a codec decode, normalising its failure to <see cref="ModbusDecodeException"/> so the
|
||||
/// classifier can tell undecodable device data from a transport fault.</summary>
|
||||
private static object Decode(Func<object> decode, ModbusTagDefinition tag)
|
||||
{
|
||||
try { return decode(); }
|
||||
catch (Exception ex) when (ex is InvalidDataException or OverflowException or ArgumentException or InvalidCastException)
|
||||
{
|
||||
throw new ModbusDecodeException($"value of {tag.Name} ({tag.DataType}) could not be decoded: {ex.Message}", ex);
|
||||
}
|
||||
}
|
||||
|
||||
private async Task<object> ReadOneAsync(IModbusTransport transport, ModbusTagDefinition tag, CancellationToken ct)
|
||||
{
|
||||
var arrayCount = tag.ArrayCount ?? 1;
|
||||
@@ -577,9 +836,9 @@ public sealed class ModbusDriver
|
||||
: await ReadRegisterBlockChunkedAsync(transport, unitId, fc, tag.Address, totalRegs, cap, ct).ConfigureAwait(false);
|
||||
|
||||
if (!tag.ArrayCount.HasValue)
|
||||
return DecodeRegister(data, tag);
|
||||
return Decode(() => DecodeRegister(data, tag), tag);
|
||||
|
||||
return DecodeRegisterArray(data, tag, elementRegs, arrayCount);
|
||||
return Decode(() => DecodeRegisterArray(data, tag, elementRegs, arrayCount), tag);
|
||||
}
|
||||
default:
|
||||
throw new InvalidOperationException($"Unknown region {tag.Region}");
|
||||
@@ -913,9 +1172,11 @@ public sealed class ModbusDriver
|
||||
/// </summary>
|
||||
private async Task<HashSet<int>> ReadCoalescedAsync(
|
||||
IModbusTransport transport,
|
||||
Dictionary<string, ModbusTagDefinition> table,
|
||||
IReadOnlyList<string> fullReferences,
|
||||
DataValueSnapshot[] results,
|
||||
DateTime timestamp,
|
||||
BatchOutcome batch,
|
||||
CancellationToken ct)
|
||||
{
|
||||
// Eligible: known tag, register region (HoldingRegisters or InputRegisters), scalar
|
||||
@@ -923,7 +1184,7 @@ public sealed class ModbusDriver
|
||||
var eligible = new List<(int Index, string Ref, ModbusTagDefinition Tag)>();
|
||||
for (var i = 0; i < fullReferences.Count; i++)
|
||||
{
|
||||
if (!_resolver.TryResolve(fullReferences[i], out var tag)) continue;
|
||||
if (!table.TryGetValue(fullReferences[i], out var tag)) continue;
|
||||
if (tag.CoalesceProhibited) continue;
|
||||
if (tag.ArrayCount.HasValue) continue;
|
||||
if (tag.Region is not (ModbusRegion.HoldingRegisters or ModbusRegion.InputRegisters)) continue;
|
||||
@@ -983,38 +1244,66 @@ public sealed class ModbusDriver
|
||||
}
|
||||
|
||||
var qty = (ushort)(block.End - block.Start + 1);
|
||||
try
|
||||
if (batch.IsFailedFast(group.Key.Unit))
|
||||
{
|
||||
var data = await ReadRegisterBlockAsync(transport, group.Key.Unit, fc, block.Start, qty, ct).ConfigureAwait(false);
|
||||
foreach (var (idx, tag) in block.Members)
|
||||
{
|
||||
var sliceOffsetBytes = (tag.Address - block.Start) * 2;
|
||||
var sliceLenBytes = RegisterCount(tag) * 2;
|
||||
var value = DecodeRegister(data.AsSpan(sliceOffsetBytes, sliceLenBytes), tag);
|
||||
results[idx] = new DataValueSnapshot(value, 0u, timestamp, timestamp);
|
||||
handled.Add(idx);
|
||||
InvalidateWriteCacheIfDiverged(fullReferences[idx], value);
|
||||
}
|
||||
WriteHealth(new DriverHealth(DriverState.Healthy, timestamp, null));
|
||||
}
|
||||
catch (ModbusException mex)
|
||||
{
|
||||
RecordAutoProhibition(group.Key.Unit, group.Key.Region, block.Start, block.End);
|
||||
WriteHealth(new DriverHealth(DriverState.Degraded, ReadHealth().LastSuccessfulRead, mex.Message));
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
// Communication failures (timeout, socket drop) aren't a structural reason
|
||||
// to prohibit the range — the same coalesced read might succeed once the
|
||||
// transport recovers. Mark members Bad for this scan but don't auto-prohibit
|
||||
// and don't deflect to per-tag fallback (which would just hit the same dead
|
||||
// socket).
|
||||
foreach (var (idx, _) in block.Members)
|
||||
{
|
||||
results[idx] = new DataValueSnapshot(null, StatusBadCommunicationError, null, timestamp);
|
||||
handled.Add(idx);
|
||||
}
|
||||
WriteHealth(new DriverHealth(DriverState.Degraded, ReadHealth().LastSuccessfulRead, ex.Message));
|
||||
continue;
|
||||
}
|
||||
byte[] data;
|
||||
try
|
||||
{
|
||||
data = await ReadRegisterBlockAsync(transport, group.Key.Unit, fc, block.Start, qty, ct).ConfigureAwait(false);
|
||||
}
|
||||
catch (OperationCanceledException) when (ct.IsCancellationRequested)
|
||||
{
|
||||
throw;
|
||||
}
|
||||
catch (ModbusException mex) when (IsRefusalCode(mex.ExceptionCode))
|
||||
{
|
||||
// The device refused the merged range (a protected hole inside it): record the range
|
||||
// as auto-prohibited and leave the members UNhandled so the per-tag fallback reads each
|
||||
// surviving address individually. The device answered, so health is not degraded.
|
||||
batch.Answered = true;
|
||||
RecordAutoProhibition(group.Key.Unit, group.Key.Region, block.Start, block.End);
|
||||
continue;
|
||||
}
|
||||
catch (Exception ex)
|
||||
{
|
||||
// Communication failures (timeout, socket drop) and non-refusal exception codes aren't
|
||||
// a structural reason to prohibit the range — the same coalesced read might succeed
|
||||
// once the transport recovers. Mark members Bad for this scan but don't auto-prohibit
|
||||
// and don't deflect to per-tag fallback (which would just hit the same dead socket).
|
||||
var status = ClassifyFailure(ex, group.Key.Unit, fullReferences[block.Members[0].Index], batch, isWrite: false);
|
||||
foreach (var (idx, _) in block.Members)
|
||||
{
|
||||
results[idx] = new DataValueSnapshot(null, status, null, timestamp);
|
||||
handled.Add(idx);
|
||||
}
|
||||
continue;
|
||||
}
|
||||
|
||||
batch.Answered = true;
|
||||
foreach (var (idx, tag) in block.Members)
|
||||
{
|
||||
var sliceOffsetBytes = (tag.Address - block.Start) * 2;
|
||||
var sliceLenBytes = RegisterCount(tag) * 2;
|
||||
handled.Add(idx);
|
||||
try
|
||||
{
|
||||
var value = Decode(() => DecodeRegister(data.AsSpan(sliceOffsetBytes, sliceLenBytes), tag), tag);
|
||||
results[idx] = new DataValueSnapshot(value, 0u, timestamp, timestamp);
|
||||
InvalidateWriteCacheIfDiverged(fullReferences[idx], value);
|
||||
}
|
||||
catch (ModbusDecodeException dex)
|
||||
{
|
||||
// One undecodable member never fails its neighbours.
|
||||
results[idx] = new DataValueSnapshot(null,
|
||||
ClassifyFailure(dex, group.Key.Unit, fullReferences[idx], batch, isWrite: false), null, timestamp);
|
||||
}
|
||||
}
|
||||
}
|
||||
}
|
||||
@@ -1124,12 +1413,13 @@ public sealed class ModbusDriver
|
||||
public async Task<IReadOnlyList<WriteResult>> WriteAsync(
|
||||
IReadOnlyList<WriteRequest> writes, CancellationToken cancellationToken)
|
||||
{
|
||||
var transport = RequireTransport();
|
||||
var (generation, transport, table) = CaptureLifecycle();
|
||||
var results = new WriteResult[writes.Count];
|
||||
var batch = new BatchOutcome();
|
||||
for (var i = 0; i < writes.Count; i++)
|
||||
{
|
||||
var w = writes[i];
|
||||
if (!_resolver.TryResolve(w.FullReference, out var tag))
|
||||
if (!table.TryGetValue(w.FullReference, out var tag))
|
||||
{
|
||||
results[i] = new WriteResult(StatusBadNodeIdUnknown);
|
||||
continue;
|
||||
@@ -1144,30 +1434,67 @@ public sealed class ModbusDriver
|
||||
results[i] = new WriteResult(0u);
|
||||
continue;
|
||||
}
|
||||
var unit = ResolveUnitId(tag);
|
||||
if (batch.IsFailedFast(unit))
|
||||
{
|
||||
results[i] = new WriteResult(StatusBadCommunicationError);
|
||||
continue;
|
||||
}
|
||||
|
||||
try
|
||||
{
|
||||
await WriteOneAsync(transport, tag, w.Value, cancellationToken).ConfigureAwait(false);
|
||||
results[i] = new WriteResult(0u);
|
||||
batch.Answered = true;
|
||||
if (_options.WriteOnChangeOnly)
|
||||
lock (_lastWrittenLock) _lastWrittenByRef[w.FullReference] = w.Value;
|
||||
}
|
||||
catch (ModbusException mex)
|
||||
catch (Exception ex)
|
||||
{
|
||||
results[i] = new WriteResult(MapModbusExceptionToStatus(mex.ExceptionCode));
|
||||
}
|
||||
catch (InvalidDataException)
|
||||
{
|
||||
results[i] = new WriteResult(StatusBadCommunicationError);
|
||||
}
|
||||
catch (Exception)
|
||||
{
|
||||
results[i] = new WriteResult(StatusBadInternalError);
|
||||
results[i] = new WriteResult(MapWriteFailure(ex, unit, w.FullReference, batch, cancellationToken));
|
||||
}
|
||||
}
|
||||
|
||||
// Write-side health: a comms failure degrades it (LastSuccessfulRead preserved); a good write or a
|
||||
// device refusal proves the device answered and clears a write-side Degraded. Generation-checked.
|
||||
ReportOutcome(generation, HealthSide.Write, batch, DateTime.UtcNow);
|
||||
return results;
|
||||
}
|
||||
|
||||
/// <summary>
|
||||
/// Write-status mapping (review 07 H7). Failures raised BEFORE the wire — a value that does not fit
|
||||
/// (<c>BadOutOfRange</c>), cannot convert (<c>BadTypeMismatch</c>) or is not supported
|
||||
/// (<c>BadNotSupported</c>) — never touch health. Device answers go through
|
||||
/// <see cref="ClassifyFailure"/> (refusal / device fault / comms fault). Transport failures —
|
||||
/// desync, timeout, socket, EOF — are <c>BadCommunicationError</c>, no longer
|
||||
/// <c>BadInternalError</c>; only a genuinely unexpected exception still is.
|
||||
/// </summary>
|
||||
private uint MapWriteFailure(Exception ex, byte unit, string tagRef, BatchOutcome batch, CancellationToken ct)
|
||||
{
|
||||
switch (ex)
|
||||
{
|
||||
case OperationCanceledException when ct.IsCancellationRequested:
|
||||
// The caller's write deadline fired (e.g. waiting on the single-flight gate). The device
|
||||
// said nothing, so health is untouched.
|
||||
return StatusBadTimeout;
|
||||
case ModbusWriteRefusedException refused:
|
||||
return refused.StatusCode;
|
||||
case OverflowException or ArgumentOutOfRangeException:
|
||||
return StatusBadOutOfRange;
|
||||
case FormatException or InvalidCastException or ArgumentException:
|
||||
return StatusBadTypeMismatch;
|
||||
case NotSupportedException:
|
||||
return StatusBadNotSupported;
|
||||
case ModbusException or ModbusDecodeException or IOException or InvalidDataException
|
||||
or System.Net.Sockets.SocketException or ObjectDisposedException or TimeoutException
|
||||
or OperationCanceledException:
|
||||
return ClassifyFailure(ex, unit, tagRef, batch, isWrite: true);
|
||||
default:
|
||||
_logger.LogWarning(ex, "Modbus write to {RawPath} failed unexpectedly. Driver={DriverInstanceId}", tagRef, _driverInstanceId);
|
||||
return StatusBadInternalError;
|
||||
}
|
||||
}
|
||||
|
||||
private bool IsRedundantWrite(string tagRef, object? value)
|
||||
{
|
||||
lock (_lastWrittenLock)
|
||||
@@ -1256,7 +1583,7 @@ public sealed class ModbusDriver
|
||||
var qty = (ushort)(bytes.Length / 2);
|
||||
var writeCap = _options.MaxRegistersPerWrite == 0 ? (ushort)123 : _options.MaxRegistersPerWrite;
|
||||
if (qty > writeCap)
|
||||
throw new InvalidOperationException(
|
||||
throw new ModbusWriteRefusedException(StatusBadOutOfRange,
|
||||
$"Write of {qty} registers to {tag.Name} exceeds MaxRegistersPerWrite={writeCap}. " +
|
||||
$"Split the tag (e.g. shorter StringLength or smaller ArrayCount) — partial FC16 chunks would lose atomicity.");
|
||||
var pdu = new byte[6 + 1 + bytes.Length];
|
||||
@@ -1270,7 +1597,7 @@ public sealed class ModbusDriver
|
||||
return;
|
||||
}
|
||||
default:
|
||||
throw new InvalidOperationException($"Writes not supported for region {tag.Region}");
|
||||
throw new ModbusWriteRefusedException(StatusBadNotWritable, $"Writes not supported for region {tag.Region}");
|
||||
}
|
||||
}
|
||||
|
||||
@@ -1281,9 +1608,12 @@ public sealed class ModbusDriver
|
||||
private static byte[] EncodeRegisterArray(object? value, ModbusTagDefinition tag)
|
||||
{
|
||||
var count = tag.ArrayCount!.Value;
|
||||
if (value is not System.Collections.IList list || list.Count != count)
|
||||
throw new InvalidOperationException(
|
||||
if (value is not System.Collections.IList list)
|
||||
throw new ModbusWriteRefusedException(StatusBadTypeMismatch,
|
||||
$"Array write to {tag.Name} expects an IList of length {count}; got {value?.GetType().Name ?? "null"}");
|
||||
if (list.Count != count)
|
||||
throw new ModbusWriteRefusedException(StatusBadOutOfRange,
|
||||
$"Array write to {tag.Name} expects {count} elements; got {list.Count}");
|
||||
|
||||
var elementBytes = ElementByteCount(tag);
|
||||
var result = new byte[count * elementBytes];
|
||||
@@ -1308,7 +1638,10 @@ public sealed class ModbusDriver
|
||||
for (var i = 0; i < expectedCount; i++) arr[i] = Convert.ToBoolean(list[i]);
|
||||
return arr;
|
||||
}
|
||||
throw new InvalidOperationException(
|
||||
if (value is System.Collections.IList wrong)
|
||||
throw new ModbusWriteRefusedException(StatusBadOutOfRange,
|
||||
$"Coil-array write to {tagName} expects {expectedCount} elements; got {wrong.Count}");
|
||||
throw new ModbusWriteRefusedException(StatusBadTypeMismatch,
|
||||
$"Coil-array write to {tagName} expects a bool[] (or convertible IList) of length {expectedCount}; got {value?.GetType().Name ?? "null"}");
|
||||
}
|
||||
|
||||
@@ -1392,12 +1725,12 @@ public sealed class ModbusDriver
|
||||
/// </summary>
|
||||
public string HostName => $"{_options.Host}:{_options.Port}";
|
||||
|
||||
private async Task ProbeLoopAsync(CancellationToken ct)
|
||||
private async Task ProbeLoopAsync(int generation, IModbusTransport transport, CancellationToken ct)
|
||||
{
|
||||
var transport = _transport; // captured reference; disposal tears the loop down via ct
|
||||
// The transport is captured at start; disposal tears the loop down via ct.
|
||||
while (!ct.IsCancellationRequested)
|
||||
{
|
||||
var success = false;
|
||||
var answered = false;
|
||||
try
|
||||
{
|
||||
using var probeCts = CancellationTokenSource.CreateLinkedTokenSource(ct);
|
||||
@@ -1405,19 +1738,28 @@ public sealed class ModbusDriver
|
||||
var pdu = new byte[] { 0x03,
|
||||
(byte)(_options.Probe.ProbeAddress >> 8),
|
||||
(byte)(_options.Probe.ProbeAddress & 0xFF), 0x00, 0x01 };
|
||||
_ = await transport!.SendAsync(_options.UnitId, pdu, probeCts.Token).ConfigureAwait(false);
|
||||
success = true;
|
||||
_ = await transport.SendAsync(_options.UnitId, pdu, probeCts.Token).ConfigureAwait(false);
|
||||
answered = true;
|
||||
}
|
||||
catch (OperationCanceledException) when (ct.IsCancellationRequested)
|
||||
{
|
||||
return;
|
||||
}
|
||||
catch (ModbusException mex) when (mex.ExceptionCode is not (0x0A or 0x0B))
|
||||
{
|
||||
// An exception PDU from the device itself (e.g. a locked probe register) proves the host
|
||||
// is up — it answered. Only a gateway reporting its target unreachable (0A/0B) is Stopped.
|
||||
answered = true;
|
||||
}
|
||||
catch
|
||||
{
|
||||
// transport / timeout / exception PDU — treated as Stopped below
|
||||
// transport / timeout / gateway-target failure — treated as Stopped below
|
||||
}
|
||||
|
||||
TransitionTo(success ? HostState.Running : HostState.Stopped);
|
||||
// A probe that finished after teardown cancelled the loop must not raise a stale transition.
|
||||
if (ct.IsCancellationRequested) return;
|
||||
if (answered) NoteDeviceAnswered(generation);
|
||||
TransitionTo(answered ? HostState.Running : HostState.Stopped);
|
||||
|
||||
try { await Task.Delay(_options.Probe.Interval, ct).ConfigureAwait(false); }
|
||||
catch (OperationCanceledException) { return; }
|
||||
@@ -1743,8 +2085,6 @@ public sealed class ModbusDriver
|
||||
return result;
|
||||
}
|
||||
|
||||
private IModbusTransport RequireTransport() =>
|
||||
_transport ?? throw new InvalidOperationException("ModbusDriver not initialized");
|
||||
|
||||
private const uint StatusBadInternalError = 0x80020000u;
|
||||
private const uint StatusBadNodeIdUnknown = 0x80340000u;
|
||||
@@ -1753,6 +2093,9 @@ public sealed class ModbusDriver
|
||||
private const uint StatusBadNotSupported = 0x803D0000u;
|
||||
private const uint StatusBadDeviceFailure = 0x808B0000u;
|
||||
private const uint StatusBadCommunicationError = 0x80050000u;
|
||||
private const uint StatusBadDecodingError = 0x80070000u;
|
||||
private const uint StatusBadTimeout = 0x800A0000u;
|
||||
private const uint StatusBadTypeMismatch = 0x80740000u;
|
||||
|
||||
/// <summary>
|
||||
/// Map a server-returned Modbus exception code to the most informative OPC UA
|
||||
@@ -1789,6 +2132,10 @@ public sealed class ModbusDriver
|
||||
/// <returns>A task that represents the asynchronous operation.</returns>
|
||||
public async ValueTask DisposeAsync()
|
||||
{
|
||||
// Dispose supersedes any in-flight (abandoned) initialize up front, even when it then has to
|
||||
// bypass the gate: that initialize will find its generation moved on and release its own
|
||||
// transport instead of publishing it after this teardown.
|
||||
lock (_stateLock) _generation++;
|
||||
if (await _lifecycleGate.WaitAsync(LifecycleGateTimeout).ConfigureAwait(false))
|
||||
{
|
||||
try
|
||||
@@ -1816,25 +2163,27 @@ public sealed class ModbusDriver
|
||||
/// </summary>
|
||||
private async Task TeardownAsync()
|
||||
{
|
||||
try { _probeCts?.Cancel(); } catch { }
|
||||
_probeCts?.Dispose();
|
||||
_probeCts = null;
|
||||
await StopBackgroundLoopsAsync().ConfigureAwait(false);
|
||||
|
||||
try { _reprobeCts?.Cancel(); } catch { }
|
||||
_reprobeCts?.Dispose();
|
||||
_reprobeCts = null;
|
||||
// Drain the poll loops BEFORE dropping the tables and caches they read, so no in-flight cycle can
|
||||
// re-seed a cache after it was cleared.
|
||||
await _poll.DisposeAsync().ConfigureAwait(false);
|
||||
// After the engine's loops are drained, no onChange can re-populate the per-cycle buffers.
|
||||
_cycleBatchItems.Clear();
|
||||
|
||||
_tagsByRawPath.Clear();
|
||||
IModbusTransport? transport;
|
||||
lock (_stateLock)
|
||||
{
|
||||
transport = _transport;
|
||||
_transport = null;
|
||||
// Swap, never .Clear() in place: a reader that captured the old table keeps a consistent view.
|
||||
Volatile.Write(ref _tagsByRawPath, new Dictionary<string, ModbusTagDefinition>(StringComparer.Ordinal));
|
||||
}
|
||||
_resolver.Clear(); // no-op in v3 (the resolver reads the live table by closure); kept for symmetry
|
||||
_lastPublishedByRef.Clear();
|
||||
lock (_lastWrittenLock) _lastWrittenByRef.Clear();
|
||||
lock (_autoProhibitedLock) _autoProhibited.Clear();
|
||||
|
||||
await _poll.DisposeAsync().ConfigureAwait(false);
|
||||
// After the engine's loops are drained, no onChange can re-populate the per-cycle buffers.
|
||||
_cycleBatchItems.Clear();
|
||||
|
||||
if (_transport is not null) await _transport.DisposeAsync().ConfigureAwait(false);
|
||||
_transport = null;
|
||||
if (transport is not null) await transport.DisposeAsync().ConfigureAwait(false);
|
||||
}
|
||||
}
|
||||
|
||||
@@ -46,7 +46,7 @@ public sealed class ModbusRtuOverTcpTransport : IModbusTransport
|
||||
private readonly Stream? _testStream;
|
||||
private readonly TimeSpan _timeout;
|
||||
private readonly SemaphoreSlim _gate = new(1, 1);
|
||||
private bool _disposed;
|
||||
private int _disposed;
|
||||
|
||||
/// <summary>Initializes a new instance of the <see cref="ModbusRtuOverTcpTransport"/> class.</summary>
|
||||
/// <param name="host">The host address or hostname of the Modbus gateway.</param>
|
||||
@@ -90,7 +90,7 @@ public sealed class ModbusRtuOverTcpTransport : IModbusTransport
|
||||
/// <inheritdoc />
|
||||
public async Task<byte[]> SendAsync(byte unitId, byte[] pdu, CancellationToken ct)
|
||||
{
|
||||
if (_disposed) throw new ObjectDisposedException(nameof(ModbusRtuOverTcpTransport));
|
||||
if (Volatile.Read(ref _disposed) != 0) throw new ObjectDisposedException(nameof(ModbusRtuOverTcpTransport));
|
||||
if (_life is null && _testStream is null) throw new InvalidOperationException("Transport not connected");
|
||||
|
||||
// Single-flight: RTU carries no transaction id, so at most one transaction may be on the bus
|
||||
@@ -187,9 +187,8 @@ public sealed class ModbusRtuOverTcpTransport : IModbusTransport
|
||||
/// <returns>A task that represents the asynchronous operation.</returns>
|
||||
public async ValueTask DisposeAsync()
|
||||
{
|
||||
if (_disposed) return;
|
||||
_disposed = true;
|
||||
if (Interlocked.Exchange(ref _disposed, 1) != 0) return;
|
||||
if (_life is not null) await _life.DisposeAsync().ConfigureAwait(false);
|
||||
_gate.Dispose();
|
||||
// _gate is deliberately NOT disposed: a SendAsync still in flight at teardown releases it in its finally.
|
||||
}
|
||||
}
|
||||
|
||||
@@ -76,6 +76,7 @@ public sealed class ModbusSocketLifecycle : IAsyncDisposable
|
||||
{
|
||||
// A previous socket (failed, torn down or idle-reaped) is released FIRST: overwriting _client
|
||||
// used to strand the old TcpClient for the finalizer — up to nine per backoff loop.
|
||||
ThrowIfDisposed();
|
||||
await TearDownAsync().ConfigureAwait(false);
|
||||
|
||||
// DNS resolution runs under the same per-op deadline as the TCP connect: an unresolvable or
|
||||
@@ -98,6 +99,7 @@ public sealed class ModbusSocketLifecycle : IAsyncDisposable
|
||||
client = new TcpClient(target.AddressFamily);
|
||||
EnableKeepAlive(client, _keepAlive);
|
||||
await client.ConnectAsync(target, _port, cts.Token).ConfigureAwait(false);
|
||||
ThrowIfDisposed(); // disposed while dialling — the finally releases the fresh client
|
||||
_stream = client.GetStream();
|
||||
_client = client;
|
||||
client = null; // ownership transferred
|
||||
@@ -258,11 +260,16 @@ public sealed class ModbusSocketLifecycle : IAsyncDisposable
|
||||
/// <returns>A task that represents the asynchronous operation.</returns>
|
||||
public async ValueTask DisposeAsync()
|
||||
{
|
||||
try
|
||||
{
|
||||
if (_stream is not null) await _stream.DisposeAsync().ConfigureAwait(false);
|
||||
}
|
||||
catch { /* best-effort */ }
|
||||
_client?.Dispose();
|
||||
// Latch first: a SendAsync still in flight (the driver tearing down under it) must not reconnect
|
||||
// a fresh socket after this point — ConnectAsync checks the latch both before and after dialling.
|
||||
Volatile.Write(ref _disposed, 1);
|
||||
await TearDownAsync().ConfigureAwait(false);
|
||||
}
|
||||
|
||||
private int _disposed;
|
||||
|
||||
private void ThrowIfDisposed()
|
||||
{
|
||||
if (Volatile.Read(ref _disposed) != 0) throw new ObjectDisposedException(nameof(ModbusSocketLifecycle));
|
||||
}
|
||||
}
|
||||
|
||||
@@ -36,7 +36,7 @@ public sealed class ModbusTcpTransport : IModbusTransport
|
||||
private readonly TimeSpan _timeout;
|
||||
private readonly SemaphoreSlim _gate = new(1, 1);
|
||||
private ushort _nextTx;
|
||||
private bool _disposed;
|
||||
private int _disposed;
|
||||
|
||||
/// <summary>Initializes a new instance of the <see cref="ModbusTcpTransport"/> class.</summary>
|
||||
/// <param name="host">The host address or hostname of the Modbus server.</param>
|
||||
@@ -65,7 +65,7 @@ public sealed class ModbusTcpTransport : IModbusTransport
|
||||
/// <inheritdoc />
|
||||
public async Task<byte[]> SendAsync(byte unitId, byte[] pdu, CancellationToken ct)
|
||||
{
|
||||
if (_disposed) throw new ObjectDisposedException(nameof(ModbusTcpTransport));
|
||||
if (Volatile.Read(ref _disposed) != 0) throw new ObjectDisposedException(nameof(ModbusTcpTransport));
|
||||
|
||||
await _gate.WaitAsync(ct).ConfigureAwait(false);
|
||||
try
|
||||
@@ -228,9 +228,8 @@ public sealed class ModbusTcpTransport : IModbusTransport
|
||||
/// <returns>A task that represents the asynchronous operation.</returns>
|
||||
public async ValueTask DisposeAsync()
|
||||
{
|
||||
if (_disposed) return;
|
||||
_disposed = true;
|
||||
if (Interlocked.Exchange(ref _disposed, 1) != 0) return;
|
||||
await _life.DisposeAsync().ConfigureAwait(false);
|
||||
_gate.Dispose();
|
||||
// _gate is deliberately NOT disposed: a SendAsync still in flight at teardown releases it in its finally.
|
||||
}
|
||||
}
|
||||
|
||||
@@ -0,0 +1,21 @@
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus;
|
||||
|
||||
/// <summary>
|
||||
/// The driver refused a write BEFORE anything reached the wire (wrong array length, a payload over
|
||||
/// <c>MaxRegistersPerWrite</c>, an unsupported shape). Carries the OPC UA status the write returns;
|
||||
/// it never touches driver health — nothing was sent.
|
||||
/// </summary>
|
||||
public sealed class ModbusWriteRefusedException : Exception
|
||||
{
|
||||
/// <summary>Initializes a new instance of the <see cref="ModbusWriteRefusedException"/> class.</summary>
|
||||
/// <param name="statusCode">The OPC UA status the write returns.</param>
|
||||
/// <param name="message">A human-readable description.</param>
|
||||
public ModbusWriteRefusedException(uint statusCode, string message)
|
||||
: base(message)
|
||||
{
|
||||
StatusCode = statusCode;
|
||||
}
|
||||
|
||||
/// <summary>Gets the OPC UA status the write returns.</summary>
|
||||
public uint StatusCode { get; }
|
||||
}
|
||||
@@ -0,0 +1,341 @@
|
||||
using System.Text.Json;
|
||||
using Microsoft.Extensions.Logging;
|
||||
using Shouldly;
|
||||
using Xunit;
|
||||
using ZB.MOM.WW.OtOpcUa.Core.Abstractions;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests;
|
||||
|
||||
/// <summary>
|
||||
/// The driver health contract (review 07 H4 + H7, and the lifecycle/fail-fast rules every driver lane
|
||||
/// must meet): a device REFUSAL is per-tag Bad with no Degraded and proves the device answered; a comms
|
||||
/// fault degrades and preserves LastSuccessfulRead; health is one write per batch; a comms timeout on
|
||||
/// one unit fails the rest of that unit's batch fast; writes map transport failures to
|
||||
/// BadCommunicationError and value problems to BadOutOfRange / BadTypeMismatch.
|
||||
/// </summary>
|
||||
[Trait("Category", "Unit")]
|
||||
public sealed class ModbusHealthContractTests
|
||||
{
|
||||
private const uint Good = 0u;
|
||||
private const uint BadOutOfRange = 0x803C0000u;
|
||||
private const uint BadDeviceFailure = 0x808B0000u;
|
||||
private const uint BadCommunicationError = 0x80050000u;
|
||||
private const uint BadTypeMismatch = 0x80740000u;
|
||||
private const uint BadNodeIdUnknown = 0x80340000u;
|
||||
|
||||
private static ModbusDriverOptions Opts(params ModbusTagDefinition[] tags) => new()
|
||||
{
|
||||
Host = "f", RawTags = ModbusRawTags.Entries(tags), Probe = new ModbusProbeOptions { Enabled = false },
|
||||
};
|
||||
|
||||
private static ModbusTagDefinition Hr(string name, ushort addr, byte? unit = null, ModbusDataType type = ModbusDataType.Int16) =>
|
||||
new(name, ModbusRegion.HoldingRegisters, addr, type, UnitId: unit);
|
||||
|
||||
private static Task<byte[]> Refuse(byte code, byte[] pdu) =>
|
||||
Task.FromException<byte[]>(new ModbusException(pdu[0], code, $"exception {code}"));
|
||||
|
||||
private static ushort Addr(byte[] pdu) => (ushort)((pdu[1] << 8) | pdu[2]);
|
||||
|
||||
private static async Task<(ModbusDriver Driver, ScriptedTransport Transport)> StartAsync(
|
||||
ModbusDriverOptions opts, ILogger<ModbusDriver>? logger = null)
|
||||
{
|
||||
var t = new ScriptedTransport();
|
||||
var d = new ModbusDriver(opts, "m1", _ => t, logger);
|
||||
await d.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
return (d, t);
|
||||
}
|
||||
|
||||
// ---------------- H4: refusals ----------------
|
||||
|
||||
[Fact]
|
||||
public async Task All_tags_refused_keeps_Healthy_and_advances_LastSuccessfulRead()
|
||||
{
|
||||
var (drv, t) = await StartAsync(Opts(Hr("A", 10), Hr("B", 11)));
|
||||
await using var _ = drv;
|
||||
t.Handler = (_, pdu, _) => Refuse(0x02, pdu);
|
||||
var before = drv.GetHealth().LastSuccessfulRead;
|
||||
|
||||
var r = await drv.ReadAsync(["A", "B"], TestContext.Current.CancellationToken);
|
||||
|
||||
r.ShouldAllBe(s => s.StatusCode == BadOutOfRange);
|
||||
var h = drv.GetHealth();
|
||||
h.State.ShouldBe(DriverState.Healthy, "a refusal means the device answered — no Degraded, no watchdog fodder");
|
||||
h.LastSuccessfulRead.ShouldNotBeNull();
|
||||
h.LastSuccessfulRead!.Value.ShouldBeGreaterThanOrEqualTo(before!.Value);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task A_refusal_after_a_comms_fault_restores_Healthy()
|
||||
{
|
||||
var (drv, t) = await StartAsync(Opts(Hr("A", 10)));
|
||||
await using var _ = drv;
|
||||
t.Handler = (_, _, _) => Task.FromException<byte[]>(new IOException("socket dropped"));
|
||||
await drv.ReadAsync(["A"], TestContext.Current.CancellationToken);
|
||||
var degraded = drv.GetHealth();
|
||||
degraded.State.ShouldBe(DriverState.Degraded);
|
||||
|
||||
t.Handler = (_, pdu, _) => Refuse(0x02, pdu);
|
||||
await drv.ReadAsync(["A"], TestContext.Current.CancellationToken);
|
||||
var h = drv.GetHealth();
|
||||
h.State.ShouldBe(DriverState.Healthy);
|
||||
h.LastSuccessfulRead!.Value.ShouldBeGreaterThanOrEqualTo(degraded.LastSuccessfulRead!.Value);
|
||||
}
|
||||
|
||||
[Theory]
|
||||
[InlineData(0x04)]
|
||||
[InlineData(0x0B)]
|
||||
public async Task Non_refusal_exception_codes_still_degrade(byte code)
|
||||
{
|
||||
// Positive control for the refusal tests: a server-failure / gateway code is NOT a refusal.
|
||||
var (drv, t) = await StartAsync(Opts(Hr("A", 10)));
|
||||
await using var _ = drv;
|
||||
t.Handler = (_, pdu, _) => Refuse(code, pdu);
|
||||
await drv.ReadAsync(["A"], TestContext.Current.CancellationToken);
|
||||
drv.GetHealth().State.ShouldBe(DriverState.Degraded);
|
||||
}
|
||||
|
||||
[Theory]
|
||||
[InlineData(false)]
|
||||
[InlineData(true)]
|
||||
public async Task Mixed_refused_and_good_batch_is_Healthy_regardless_of_tag_order(bool refusedFirst)
|
||||
{
|
||||
var (drv, t) = await StartAsync(Opts(Hr("Refused", 10), Hr("Fine", 50)));
|
||||
await using var _ = drv;
|
||||
t.Handler = (_, pdu, _) => Addr(pdu) == 10 ? Refuse(0x02, pdu) : null;
|
||||
string[] refs = refusedFirst ? ["Refused", "Fine"] : ["Fine", "Refused"];
|
||||
var r = await drv.ReadAsync(refs, TestContext.Current.CancellationToken);
|
||||
r.Count(s => s.StatusCode == Good).ShouldBe(1);
|
||||
drv.GetHealth().State.ShouldBe(DriverState.Healthy);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task A_refused_tag_warns_once_not_once_per_poll()
|
||||
{
|
||||
var logger = new ListLogger();
|
||||
var (drv, t) = await StartAsync(Opts(Hr("A", 10)), logger);
|
||||
await using var _ = drv;
|
||||
t.Handler = (_, pdu, _) => Refuse(0x02, pdu);
|
||||
for (var i = 0; i < 3; i++) await drv.ReadAsync(["A"], TestContext.Current.CancellationToken);
|
||||
logger.Warnings.Count(m => m.Contains("refused") && m.Contains("A")).ShouldBe(1);
|
||||
}
|
||||
|
||||
// ---------------- fail fast per unit / endpoint ----------------
|
||||
|
||||
[Fact]
|
||||
public async Task A_comms_timeout_on_one_unit_fails_the_rest_of_that_units_batch_fast()
|
||||
{
|
||||
var (drv, t) = await StartAsync(Opts(Hr("U2a", 10, 2), Hr("U2b", 11, 2), Hr("U2c", 12, 2), Hr("U1", 13, 1)));
|
||||
await using var _ = drv;
|
||||
t.Bank.HoldingRegisters[13] = 42;
|
||||
t.Handler = (unit, _, _) => unit == 2
|
||||
? Task.FromException<byte[]>(new ModbusTransportDesyncException(
|
||||
ModbusTransportDesyncException.DesyncReason.Timeout, "timeout"))
|
||||
: null;
|
||||
|
||||
var r = await drv.ReadAsync(["U2a", "U2b", "U2c", "U1"], TestContext.Current.CancellationToken);
|
||||
|
||||
t.SendsTo(2).ShouldBe(1, "one timeout per unit per batch, not one per tag");
|
||||
r.Take(3).ShouldAllBe(s => s.StatusCode == BadCommunicationError);
|
||||
// Positive control: the healthy unit in the same batch is still read.
|
||||
r[3].StatusCode.ShouldBe(Good);
|
||||
r[3].Value.ShouldBe((short)42);
|
||||
drv.GetHealth().State.ShouldBe(DriverState.Degraded);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task An_unreachable_endpoint_fails_the_whole_batch_fast()
|
||||
{
|
||||
var (drv, t) = await StartAsync(Opts(Hr("A", 10, 1), Hr("B", 11, 2), Hr("C", 12, 3)));
|
||||
await using var _ = drv;
|
||||
t.Handler = (_, _, _) => Task.FromException<byte[]>(new ModbusTransportUnavailableException("throttled"));
|
||||
var r = await drv.ReadAsync(["A", "B", "C"], TestContext.Current.CancellationToken);
|
||||
t.TotalSends.ShouldBe(1);
|
||||
r.ShouldAllBe(s => s.StatusCode == BadCommunicationError);
|
||||
}
|
||||
|
||||
// ---------------- H7: write status mapping + write-side health ----------------
|
||||
|
||||
[Fact]
|
||||
public async Task Write_transport_failure_is_BadCommunicationError_and_degrades_the_write_side()
|
||||
{
|
||||
var (drv, t) = await StartAsync(Opts(Hr("A", 10)));
|
||||
await using var _ = drv;
|
||||
t.Handler = (_, pdu, _) => pdu[0] == 0x06 ? Task.FromException<byte[]>(new IOException("dropped")) : null;
|
||||
|
||||
var w = await drv.WriteAsync([new WriteRequest("A", (short)1)], TestContext.Current.CancellationToken);
|
||||
w[0].StatusCode.ShouldBe(BadCommunicationError);
|
||||
drv.GetHealth().State.ShouldBe(DriverState.Degraded);
|
||||
|
||||
// A good READ does not clear a write-side fault...
|
||||
(await drv.ReadAsync(["A"], TestContext.Current.CancellationToken))[0].StatusCode.ShouldBe(Good);
|
||||
drv.GetHealth().State.ShouldBe(DriverState.Degraded);
|
||||
|
||||
// ...a good WRITE does.
|
||||
t.Handler = null;
|
||||
(await drv.WriteAsync([new WriteRequest("A", (short)2)], TestContext.Current.CancellationToken))[0].StatusCode.ShouldBe(Good);
|
||||
drv.GetHealth().State.ShouldBe(DriverState.Healthy);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task A_write_refusal_counts_as_answered_and_clears_a_write_side_fault()
|
||||
{
|
||||
var (drv, t) = await StartAsync(Opts(Hr("A", 10)));
|
||||
await using var _ = drv;
|
||||
t.Handler = (_, pdu, _) => pdu[0] == 0x06 ? Task.FromException<byte[]>(new IOException("dropped")) : null;
|
||||
await drv.WriteAsync([new WriteRequest("A", (short)1)], TestContext.Current.CancellationToken);
|
||||
drv.GetHealth().State.ShouldBe(DriverState.Degraded);
|
||||
|
||||
t.Handler = (_, pdu, _) => pdu[0] == 0x06 ? Refuse(0x03, pdu) : null;
|
||||
var w = await drv.WriteAsync([new WriteRequest("A", (short)1)], TestContext.Current.CancellationToken);
|
||||
w[0].StatusCode.ShouldBe(BadOutOfRange);
|
||||
drv.GetHealth().State.ShouldBe(DriverState.Healthy);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task Write_value_problems_map_to_OutOfRange_and_TypeMismatch_without_touching_health()
|
||||
{
|
||||
var arr = new ModbusTagDefinition("Arr", ModbusRegion.HoldingRegisters, 20, ModbusDataType.Int16, ArrayCount: 3);
|
||||
var (drv, t) = await StartAsync(Opts(Hr("Bcd", 10, type: ModbusDataType.Bcd16), Hr("I16", 11), arr));
|
||||
await using var _ = drv;
|
||||
|
||||
var w = await drv.WriteAsync([
|
||||
new WriteRequest("Bcd", 12345), // > 4 BCD digits
|
||||
new WriteRequest("I16", 70000), // > Int16
|
||||
new WriteRequest("I16", "not a number"),
|
||||
new WriteRequest("Arr", new short[] { 1, 2 }), // length mismatch
|
||||
new WriteRequest("Arr", new int[] { 1, 2, 3 }), // CLR list of another element type converts (ScadaBridge shape)
|
||||
], TestContext.Current.CancellationToken);
|
||||
|
||||
w[0].StatusCode.ShouldBe(BadOutOfRange);
|
||||
w[1].StatusCode.ShouldBe(BadOutOfRange);
|
||||
w[2].StatusCode.ShouldBe(BadTypeMismatch);
|
||||
w[3].StatusCode.ShouldBe(BadOutOfRange);
|
||||
w[4].StatusCode.ShouldBe(Good);
|
||||
t.Bank.HoldingRegisters[22].ShouldBe((ushort)3);
|
||||
drv.GetHealth().State.ShouldBe(DriverState.Healthy);
|
||||
}
|
||||
|
||||
// ---------------- lifecycle generation ----------------
|
||||
|
||||
[Fact]
|
||||
public async Task A_superseded_initialize_never_publishes_over_the_shutdown_that_overtook_it()
|
||||
{
|
||||
var t = new ScriptedTransport { ConnectGate = new TaskCompletionSource(TaskCreationOptions.RunContinuationsAsynchronously) };
|
||||
var drv = new ModbusDriver(Opts(Hr("A", 10)), "m1", _ => t) { LifecycleGateTimeout = TimeSpan.FromSeconds(1) };
|
||||
var init = drv.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
await t.ConnectEntered.Task.WaitAsync(TimeSpan.FromSeconds(5), TestContext.Current.CancellationToken);
|
||||
|
||||
// The init is wedged in its connect; shutdown waits out the gate timeout and tears down anyway.
|
||||
await drv.ShutdownAsync(TestContext.Current.CancellationToken);
|
||||
drv.GetHealth().State.ShouldBe(DriverState.Unknown);
|
||||
|
||||
t.ConnectGate.SetResult(); // the abandoned connect finally completes
|
||||
await Should.ThrowAsync<OperationCanceledException>(() => init);
|
||||
|
||||
drv.GetHealth().State.ShouldBe(DriverState.Unknown, "the superseded init must not publish Healthy");
|
||||
t.DisposeCount.ShouldBe(1, "the superseded init releases the transport it built");
|
||||
await Should.ThrowAsync<InvalidOperationException>(() => drv.ReadAsync(["A"], TestContext.Current.CancellationToken));
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task A_read_that_straddles_a_reinitialize_does_not_write_health_about_the_new_transport()
|
||||
{
|
||||
var first = new ScriptedTransport();
|
||||
var second = new ScriptedTransport();
|
||||
var release = new TaskCompletionSource<byte[]>(TaskCreationOptions.RunContinuationsAsynchronously);
|
||||
var entered = new TaskCompletionSource(TaskCreationOptions.RunContinuationsAsynchronously);
|
||||
first.Handler = (_, _, _) => { entered.TrySetResult(); return release.Task; };
|
||||
var calls = 0;
|
||||
var drv = new ModbusDriver(Opts(Hr("A", 10)), "m1", _ => Interlocked.Increment(ref calls) == 1 ? first : second);
|
||||
await using var _ = drv;
|
||||
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
|
||||
var read = drv.ReadAsync(["A"], TestContext.Current.CancellationToken);
|
||||
await entered.Task.WaitAsync(TimeSpan.FromSeconds(5), TestContext.Current.CancellationToken);
|
||||
|
||||
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken); // re-init onto `second`
|
||||
drv.GetHealth().State.ShouldBe(DriverState.Healthy);
|
||||
|
||||
release.SetException(new IOException("old socket died")); // the straddling read now fails
|
||||
(await read)[0].StatusCode.ShouldBe(BadCommunicationError);
|
||||
drv.GetHealth().State.ShouldBe(DriverState.Healthy, "a read on the superseded transport must not degrade the new one");
|
||||
|
||||
// Positive control: a failure on the CURRENT transport still degrades.
|
||||
second.Handler = (_, _, _) => Task.FromException<byte[]>(new IOException("new socket died"));
|
||||
await drv.ReadAsync(["A"], TestContext.Current.CancellationToken);
|
||||
drv.GetHealth().State.ShouldBe(DriverState.Degraded);
|
||||
}
|
||||
|
||||
[Fact]
|
||||
public async Task Reinitialize_with_a_new_tag_set_drops_tags_the_new_config_no_longer_has()
|
||||
{
|
||||
var t = new ScriptedTransport();
|
||||
var drv = new ModbusDriver(Opts(Hr("Old", 10)), "m1", _ => t);
|
||||
await using var _ = drv;
|
||||
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
(await drv.ReadAsync(["Old"], TestContext.Current.CancellationToken))[0].StatusCode.ShouldBe(Good);
|
||||
|
||||
var config = JsonSerializer.Serialize(new
|
||||
{
|
||||
host = "f",
|
||||
probe = new { enabled = false },
|
||||
rawTags = ModbusRawTags.Entries([Hr("New", 11)]),
|
||||
});
|
||||
await drv.InitializeAsync(config, TestContext.Current.CancellationToken);
|
||||
|
||||
var r = await drv.ReadAsync(["Old", "New"], TestContext.Current.CancellationToken);
|
||||
r[0].StatusCode.ShouldBe(BadNodeIdUnknown, "a re-init publishes a fresh table, it does not merge into the old one");
|
||||
r[1].StatusCode.ShouldBe(Good);
|
||||
}
|
||||
|
||||
// ---------------- complete teardown ----------------
|
||||
|
||||
[Fact]
|
||||
public async Task Shutdown_joins_the_probe_loop_so_no_host_transition_fires_after_it_returns()
|
||||
{
|
||||
var t = new ScriptedTransport();
|
||||
var probeBlocked = new TaskCompletionSource(TaskCreationOptions.RunContinuationsAsynchronously);
|
||||
var probes = 0;
|
||||
t.Handler = async (_, pdu, ct) =>
|
||||
{
|
||||
if (Interlocked.Increment(ref probes) == 1) return await t.Bank.SendAsync(1, pdu, ct); // first probe: Running
|
||||
probeBlocked.TrySetResult();
|
||||
try { await Task.Delay(Timeout.Infinite, ct); }
|
||||
catch (OperationCanceledException) { }
|
||||
throw new ObjectDisposedException("transport"); // a teardown-time failure, NOT an OCE
|
||||
};
|
||||
var opts = new ModbusDriverOptions
|
||||
{
|
||||
Host = "f", RawTags = ModbusRawTags.Entries([Hr("A", 10)]),
|
||||
Probe = new ModbusProbeOptions { Enabled = true, Interval = TimeSpan.FromMilliseconds(50), Timeout = TimeSpan.FromSeconds(30) },
|
||||
};
|
||||
var drv = new ModbusDriver(opts, "m1", _ => t);
|
||||
var running = new TaskCompletionSource(TaskCreationOptions.RunContinuationsAsynchronously);
|
||||
var afterShutdown = new TaskCompletionSource(TaskCreationOptions.RunContinuationsAsynchronously);
|
||||
var shutdownReturned = false;
|
||||
drv.OnHostStatusChanged += (_, e) =>
|
||||
{
|
||||
if (e.NewState == HostState.Running) running.TrySetResult();
|
||||
if (Volatile.Read(ref shutdownReturned)) afterShutdown.TrySetResult();
|
||||
};
|
||||
await drv.InitializeAsync("{}", TestContext.Current.CancellationToken);
|
||||
await running.Task.WaitAsync(TimeSpan.FromSeconds(5), TestContext.Current.CancellationToken); // positive control
|
||||
await probeBlocked.Task.WaitAsync(TimeSpan.FromSeconds(5), TestContext.Current.CancellationToken);
|
||||
|
||||
await drv.ShutdownAsync(TestContext.Current.CancellationToken);
|
||||
Volatile.Write(ref shutdownReturned, true);
|
||||
|
||||
await Should.ThrowAsync<TimeoutException>(
|
||||
() => afterShutdown.Task.WaitAsync(TimeSpan.FromSeconds(1), TestContext.Current.CancellationToken));
|
||||
}
|
||||
|
||||
private sealed class ListLogger : ILogger<ModbusDriver>
|
||||
{
|
||||
public System.Collections.Concurrent.ConcurrentQueue<string> Messages { get; } = new();
|
||||
public IEnumerable<string> Warnings => Messages.Where(m => m.StartsWith("Warning:", StringComparison.Ordinal));
|
||||
public IDisposable? BeginScope<TState>(TState state) where TState : notnull => null;
|
||||
public bool IsEnabled(LogLevel logLevel) => true;
|
||||
public void Log<TState>(LogLevel logLevel, EventId eventId, TState state, Exception? exception, Func<TState, Exception?, string> formatter)
|
||||
=> Messages.Enqueue($"{logLevel}: {formatter(state, exception)}");
|
||||
}
|
||||
}
|
||||
@@ -92,7 +92,7 @@ public sealed class ModbusLoggerInjectionTests
|
||||
|
||||
// Scan 1 — coalesced read fails. Expect exactly one warning.
|
||||
await drv.ReadAsync(["T100", "T102", "T104"], CancellationToken.None);
|
||||
var warnings = logger.Entries.Where(e => e.Level == LogLevel.Warning).ToList();
|
||||
var warnings = logger.Entries.Where(e => e.Level == LogLevel.Warning && e.Message.Contains("auto-prohibited")).ToList();
|
||||
warnings.Count.ShouldBe(1);
|
||||
warnings[0].Message.ShouldContain("drv-logged");
|
||||
warnings[0].Message.ShouldContain("Start=100");
|
||||
@@ -102,7 +102,13 @@ public sealed class ModbusLoggerInjectionTests
|
||||
// the prohibition and skips the merge; even if it didn't, the de-dupe in
|
||||
// RecordAutoProhibition would suppress).
|
||||
await drv.ReadAsync(["T100", "T102", "T104"], CancellationToken.None);
|
||||
logger.Entries.Count(e => e.Level == LogLevel.Warning).ShouldBe(1, "re-fire of same range stays silent");
|
||||
logger.Entries.Count(e => e.Level == LogLevel.Warning && e.Message.Contains("auto-prohibited"))
|
||||
.ShouldBe(1, "re-fire of same range stays silent");
|
||||
// The protected register's per-tag fallback is a device refusal: one Warning for that tag across
|
||||
// both scans (once-per-tag), and none for its readable neighbours.
|
||||
var refusals = logger.Entries.Where(e => e.Level == LogLevel.Warning && e.Message.Contains("refused")).ToList();
|
||||
refusals.Count.ShouldBe(1);
|
||||
refusals[0].Message.ShouldContain("T102");
|
||||
|
||||
await drv.ShutdownAsync(CancellationToken.None);
|
||||
}
|
||||
|
||||
@@ -0,0 +1,51 @@
|
||||
using System.Collections.Concurrent;
|
||||
|
||||
namespace ZB.MOM.WW.OtOpcUa.Driver.Modbus.Tests;
|
||||
|
||||
/// <summary>
|
||||
/// In-memory transport whose every send is answered by a test-supplied handler; falls back to the
|
||||
/// register/coil bank fake (<see cref="ModbusDriverTests.FakeTransport"/>) when the handler returns null.
|
||||
/// Counts sends per unit and dispose calls; the connect can be blocked on a gate.
|
||||
/// </summary>
|
||||
internal sealed class ScriptedTransport : IModbusTransport
|
||||
{
|
||||
private readonly ConcurrentDictionary<byte, int> _sendsByUnit = new();
|
||||
private int _disposeCount;
|
||||
|
||||
/// <summary>The bank answering un-scripted sends.</summary>
|
||||
public ModbusDriverTests.FakeTransport Bank { get; } = new();
|
||||
|
||||
/// <summary>Per-send handler; return null to fall through to <see cref="Bank"/>.</summary>
|
||||
public Func<byte, byte[], CancellationToken, Task<byte[]>?>? Handler { get; set; }
|
||||
|
||||
/// <summary>When set, <see cref="ConnectAsync"/> waits for it before completing.</summary>
|
||||
public TaskCompletionSource? ConnectGate { get; set; }
|
||||
|
||||
/// <summary>Signalled when <see cref="ConnectAsync"/> is entered.</summary>
|
||||
public TaskCompletionSource ConnectEntered { get; } = new(TaskCreationOptions.RunContinuationsAsynchronously);
|
||||
|
||||
public int DisposeCount => Volatile.Read(ref _disposeCount);
|
||||
|
||||
public int SendsTo(byte unit) => _sendsByUnit.TryGetValue(unit, out var n) ? n : 0;
|
||||
|
||||
public int TotalSends => _sendsByUnit.Values.Sum();
|
||||
|
||||
public async Task ConnectAsync(CancellationToken ct)
|
||||
{
|
||||
ConnectEntered.TrySetResult();
|
||||
if (ConnectGate is { } gate) await gate.Task.WaitAsync(ct);
|
||||
}
|
||||
|
||||
public Task<byte[]> SendAsync(byte unitId, byte[] pdu, CancellationToken ct)
|
||||
{
|
||||
_sendsByUnit.AddOrUpdate(unitId, 1, (_, n) => n + 1);
|
||||
var scripted = Handler?.Invoke(unitId, pdu, ct);
|
||||
return scripted ?? Bank.SendAsync(unitId, pdu, ct);
|
||||
}
|
||||
|
||||
public ValueTask DisposeAsync()
|
||||
{
|
||||
Interlocked.Increment(ref _disposeCount);
|
||||
return ValueTask.CompletedTask;
|
||||
}
|
||||
}
|
||||
Reference in New Issue
Block a user